1 ID: J-OP-02 Biomed Tech 2016; 61 (s90) by Walter de Gruyter Berlin Boston. DOI /bmt S90 Ventilation with Expiratory Ventilation Assistance In vivo evaluation of a mechanical ventilator prototype Johannes Schmidt, Department of Anesthesiology and Critical Care, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany, johannes.schmidt@uniklinik-freiburg.de Christin Wenzel, Department of Anesthesiology and Critical Care, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany, christin.wenzel@uniklinik-freiburg.de Marlene Mahn, Department of Anesthesiology and Critical Care, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany, marlene.mahn@uniklinik-freiburg.de Sashko Spassov, Department of Anesthesiology and Critical Care, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany, sashko.spassov@uniklinik-freiburg.de Heidi Cristina-Schmitz, Department of Anesthesiology and Critical Care, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany, heidi.cristina.schmitz@uniklinik-freiburg.de Silke Borgmann, Department of Anesthesiology and Critical Care, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany, silke.borgmann@uniklinik-freiburg.de Jörg Haberstroh, Experimental Surgery, Center for Experimental Models and Transgenic Service, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany, joerg.haberstroh@uniklinik-freiburg.de Stephan Meckel, Department of Neuroradiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany, stephan.meckel@uniklinik-freiburg.de Steffen Wirth, Department of Anesthesiology and Critical Care, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany, steffen.wirth@uniklinik-freiburg.de Stefan Schumann, Department of Anesthesiology and Critical Care, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany, stefan.schumann@uniklinik-freiburg.de Emergency access to the airway with small bore catheters is commonly accepted. However, ventilation is limited by insufficient expiratory flow due to the generated high airway resistance. In a controlled in-vivo trial we evaluate a new automatic mechanical ventilator with an Expiratory Ventilation Assistance (EVA) via a cuffed endotracheal tube having an inner diameter of 2 mm. This allows a fully controlled ventilation, i.e. flow controlled inspiration and active expiration induced by suctioning. Anesthetised pigs (40-51 kg, 7 per group) were either ventilated with a conventional ventilator (Evita 4, Dräger Medical, Lübeck, Germany; = control group) or the mechanical EVA-ventilator prototype (Ventinova Medical BV, Eindhoven, The Netherlands; = EVA group) for five hours. Respiratory parameters, arterial blood gases (ABG) and hemodynamic markers were recorded hourly. After five hours a computed tomography (CT) of the thorax was performed. For statistical analyses the Welch s t-test was performed. The EVA-ventilator achieved a minute volume up to 6.2 l/min. Mean airway pressure was significantly higher in the EVA group compared to the control group (12.0 ± 0.6 mbar vs. 8.9 ± 0.2 mbar, p=0.0007). Arterial O 2 partial pressure was significantly higher in the EVA-group (142.6 ± 5.6 mmhg vs ± 3.1 mmhg, p=0.006). Despite a significantly lower minute volume in the EVA group (5.5 ± 0.4 l/min vs. 6.7 ± 0.9 l/min, p=0.04), arterial CO 2 partial pressure was comparable in both groups (41.3 ± 1.6 mmhg vs ± 1.2 mmhg, p=0.83). Mean arterial pressure was significantly lower in the EVA group (71 ± 9 mmhg vs. 89 ± 9 mmhg, p=0.02). The CT revealed a more constant and steady distribution of ventilation during a breathing cycle in the EVA group. Our results suggest that gas exchange is improved due to increased alveolar ventilation with EVA.

2 ID: J-OP-03 Biomed Tech 2016; 61 (s91) by Walter de Gruyter Berlin Boston. DOI /bmt S91 Pressure-flow characteristics of coaxial tubing systems C. Wenzel, Department of Anesthesiology and Critical Care, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany, christin.wenzel@uniklinik-freiburg.de S. Schumann, Department of Anesthesiology and Critical Care, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany, stefan.schumann@uniklinik-freiburg.de J. Spaeth, Department of Anesthesiology and Critical Care, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany, johannes.spaeth@uniklinik-freiburg.de During mechanical ventilation, tubing systems represent an essential component of the artificial airways. Conventional, a circular tubing system comprises two separate tubes one for inspiration and one for expiration, a Y-piece and a 90 connector. Since recently, coaxial tubing systems (coaxts) are available. These coaxts include the inspiratory tube within the expiratory tube s lumen. By design, this facilitates clinical handling. However, the cross section areas of the inspiratory and expiratory tubes are reduced, which may impact resistance to airflow. We hypothesized that coaxts increase resistance to airflow and related work of breathing (WOB) compared to conventional tubing systems. Therefore, we determined the flow-dependent pressure gradient ( P) across a conventional reusable tubing system (crts; composed of two silicone tubes, Y-piece and 90 -connector), a conventional disposable tubing system (cdts; composed of two plastic tubes, Y-piece and 90 -connector) and coaxts, the latter two from three different manufacturers. Additionally, P across the isolated 90 -connectors were determined. To test the clinical implications of our findings, the tubing related WOB and perception of discomfort of breathing through the different types of tubing systems were investigated in 14 volunteers. At a representative flow rate of 1.0 L/s coaxts showed the highest P (5.0±0.1 cmh 2O), followed by cdts (1.4±0.1 cmh 2O) and crts (1.3±0.1 cmh 2O; two-way ANOVA, p<0.001). P across coaxts was significantly higher in expiration compared to inspiration (p<0.001) and varied between manufacturers (p<0.05). At the same flow rate the 90 connector caused up to 40% from P in cdts but only 8% in crts, respectively. Additional WOB was up to fourfold higher in coaxts compared to crts (4.0±2.3 vs. 0.95±0.53 J/min; one-way ANOVA, p<0.0001) and discomfort was rated the highest across coaxts (11 from 14 volunteers). As a result from our study, coaxial tubing systems should be carefully considered in patients with pathologically increased airway resistance.

3 ID: J-OP-04 Biomed Tech 2016; 61 (s92) by Walter de Gruyter Berlin Boston. DOI /bmt S92 Comparative Assessment of Stroke Patients' Upper Limb Tasks to Evaluate a System Based on Inertial Measurement Units and Fuzzy Logic Braulio Roberto Duarte Benitez, Department of Rehabilitation & Prevention Engineering, Institute of Applied Medical Engineering, RWTH Aachen University, Aachen, Germany, duarte@ame.rwth-aachen.de Catherine Disselhorst-Klug, Department of Rehabilitation & Prevention Engineering, Institute of Applied Medical Engineering, RWTH Aachen University, Aachen, Germany, disselhorst-klug@ame.rwth-aachen.de According to the World Health Organization, per year 15 million people suffer a stroke worldwide. Of these, 5 million are permanently disabled. Currently there are several methods to evaluate upper limb movements on stroke patients; they are mostly based on observation by physicians and physiotherapists, whose judgement is influenced by experience and subjective impressions. This study was done on 16 stroke patients, using a system which is based on four Inertial Measurement Units (IMUs) which are composed of accelerometers, gyroscopes, and magnetometers. Each sensor was placed on each segment of the patient s arm, i.e. scapula, arm, forearm, and hand. Every patient was told to perform simple movements with the arm, such as move the hand to the mouth and hand to the head starting from a resting position while they were standing, or sitting when requiring a wheelchair. Repeated movements were performed continuously between 15 and 20 times, while the data from the IMUs were recorded. Afterwards, the data were processed to obtain the orientation of every segment of the arm, given as Euler angles in relation to a laboratory coordinate system. The Euler angles were run through a Fuzzy Logic algorithm. The resulting values from a specific repetition were compared with other repetitions of the same exercise, assigning a score to each repetition based on a final scaled value between 0 and 10. Physiotherapists were asked to evaluate the patients movements. Comparing their evaluation with the proposed methodology, physiotherapists were able to highlight certain characteristics from the movements on a specific period of the exercise. In contrast with physiotherapists, Fuzzy algorithm considers and processes what the patient performed during the entire exercise. The outcome from the Fuzzy algorithm offered an objective, stable and consistent movement evaluation which was independent of the performed task and the analyzed patient.

4 ID: J-OP-05 Biomed Tech 2016; 61 (s93) by Walter de Gruyter Berlin Boston. DOI /bmt S93 In vitro assessment of the effects of high glucose levels on rheological blood parameters. Steven Ndzengue, Institute for Multiphase Processes, Leibniz Universität Hannover, Germany, Marc Müller, Institute for Multiphase Processes, Leibniz Universität Hannover, Germany, Jörg Vienken, Usingen, Germany, Birgit Glasmacher, Institute for Multiphase Processes, Leibniz Universität Hannover, Germany, Diabetic patients suffering from a nephropathy are candidates for a hemodialysis treatment which is related with a lower survival outcome compared to hemodialysis patients from other underlying diseases. Apart from providing energy by oxidation, glucose can also be stored in the organism. Beyond this energetic function, elevated blood glucose levels also lead to changes in blood composition. It can be assumed, that rheological changes of blood from hyperglycemic or even diabetic patients have a direct impact on the effectiveness of the hemodialysis treatment. The aim of the study is to investigate the effects of high blood glucose levels on rheological blood parameters by exposing blood from healthy pigs to an in vitro artificial diabetic environment. The corpuscular blood components as well as clinically relevant rheological variables were examined in porcine citrate blood samples with different glucose concentrations. Purpose-built one-molar glucose solutions were added into blood samples in order to reach the required final concentrations (5, and mmol/l). Hematocrit (Hct) as well as thrombocytes concentration (Thr) among others were assessed every 30 min in blood vials held under dynamic conditions for up to 3 hours at 37 C using an automatic hematology system. Clotting time (Clt) was also measured using a coagulation system. Normoglycemic samples with native glucose concentration in range from 3.9 to 4.5 mmol/l served as control and just remained untreated. The samples treated with glucose showed a lower Clt compared to the controls. Clt decreased with increasing glucose concentrations. Hematocrit increased with time and increasing glucose concentrations while thrombocytes concentration decreased with time and decreasing glucose concentrations. Elevated blood glucose levels lead to faster clotting, lower thrombocytes concentration and higher hematocrit. Consequently, a disturbed blood flow is expected to negatively affect the effectiveness of dialysis.

5 ID: J-PP-01 Biomed Tech 2016; 61 (s94) by Walter de Gruyter Berlin Boston. DOI /bmt S94 Camera-based pulse transition time measurement for blood pressure estimation Fabian Schrumpf, Laboratory for Biosignal Processing, Leipzig University of Applied Sciences (HTWK), Leipzig, Germany, Juliane Bauer, Laboratory for Biosignal Processing, Leipzig University of Applied Sciences (HTWK), Leipzig, Germany, Bianca Reichard, Laboratory for Biosignal Processing, Leipzig University of Applied Sciences (HTWK), Leipzig, Germany, Daniel Matthes, Laboratory for Biosignal Processing, Leipzig University of Applied Sciences (HTWK), Leipzig, Germany, Mirco Fuchs, Laboratory for Biosignal Processing, Leipzig University of Applied Sciences (HTWK), Leipzig, Germany, Photoplethysmograhpy (PPG) is a technique that allows non-invasive monitoring of blood volume dynamics by means of optical sensors. It is usually sensed at a finger or the wrist and used for pulse rate, respiratory rate, and even blood pressure estimation. The latter is correlated to the pulse wave velocity which can be estimated by means of the pulse transit time (PTT), i.e. the time in which a pulse wave passes a certain distance. One approach to determine the PTT is measuring the time difference between the electrical stimulation of the heart and the systolic peak amplitude in the PPG signal. Another method is solely based on the PPG signal, i.e. on time differences between the maximum systolic and diastolic amplitude. In recent years, the PPG principle has been utilized by several research groups for camera-based pulse rate detection by means of remote PPG (rppg). That is, blood volume dynamics are estimated on the basis of particular color information in consecutive pictures of, e.g., the face. However, rppg signals are prone to errors due to, e.g., movement and ambient light. This usually leads to a poor signal quality. Therefore, none of the available methods to estimate the PTT is actually suited for camera-based measurements. In this work we present a new method which aims to provide PTT estimation for camera-based applications. It is based on the idea to detect rppg signals in at least two distinct face regions. The PTT between these regions is going to be determined by means of cross-correlation. The method is systematically evaluated according to the location of the employed regions using experimental data. Our method is the basis for the camera-based detection of blood pressure which might open a wide range of medical and home care applications.

6 ID: J-PP-02 Biomed Tech 2016; 61 (s95) by Walter de Gruyter Berlin Boston. DOI /bmt S95 Skin detection based ROI selection for the analysis of rppg signals in newborns Daniel Matthes, Laboratory for Biosignal Processing, Leipzig University of Applied Sciences (HTWK), Leipzig, Germany, Christoph Mönch, Laboratory for Biosignal Processing, Leipzig University of Applied Sciences (HTWK), Leipzig, Germany, Fabian Schrumpf, Laboratory for Biosignal Processing, Leipzig University of Applied Sciences (HTWK), Leipzig, Germany, Mirco Fuchs, Laboratory for Biosignal Processing, Leipzig University of Applied Sciences (HTWK), Leipzig, Germany, Gerold Bausch, Laboratory for Biosignal Processing, Leipzig University of Applied Sciences (HTWK), Leipzig, Germany, Remote photoplethysmography (rppg) is a technique that allows the camera-based detection of blood volume dynamics in arteries located in the upper skin layers. It is based on the absorption of characteristic wavelength in visible light caused by, e.g., oxygenated hemoglobin. Since the amount of oxygenated blood is modulated by the heart beat rppg allows, e.g., the estimation of the heart frequency only by means of a camera. We utilized this method for the non-invasive measurement of several vital parameters in newborns. A major issue for such an application is the automated robust detection of regions (ROIs) in which strong signals can be expected, usually the forehead or the cheek. Common approaches employ face detection (e.g., according to Viola/Jones) and a subsequent offset-based placement of the ROIs. However, this usually require (1) recording from a frontal direction, and (2) opened eyes of the recorded person in order to provide stable results. We propose an alternative approach that is based on skin detection by means of the hue component in HSV color space and an adaptive optimization of skin detection parameters. The hue is particularly suited since it is widely independent from the lighting conditions. We further applied edge detection algorithms to identify other skin colored objects close to the head, e.g., hands and arms of newborns. Next, the detected skin area is used to estimate the facial region by means of fitting an ellipsoid. This is used as a reference to finally place the desired ROIs. We applied our method to the rppg-based detection of the pulse frequency in newborns. We conducted datasets of 30 healthy newborns at several maternal wards. A Finger-clip based measurement served as reference. Our method provides a stable detection of the pulse, even in situations where other face detection based methods provide no results at all.

Technical specifications

Technical specifications Technical specifications Breathing set, dual limb, non-heated for HAMILTON-C1/T1/MR1 PN 260180 PN 260170 PN 260182 PN 260169 PN 260241 PN 260244 150 cm (w/o expiratory valve) 150 cm 300 cm (w/o expiratory

More information

Blood Pressure Estimation Using Photoplethysmography (PPG)

Blood Pressure Estimation Using Photoplethysmography (PPG) Blood Pressure Estimation Using Photoplethysmography (PPG) 1 Siddhi Sham Karande, BE E&TC, VIIT Pune. 2 Kiran Rajendrasingh Thakur, BE E&TC, VIIT Pune. 3 Sneha Dattatraya Waghmare, BE E&TC, VIIT Pune 4

More information

Heart Abnormality Detection Technique using PPG Signal

Heart Abnormality Detection Technique using PPG Signal Heart Abnormality Detection Technique using PPG Signal L.F. Umadi, S.N.A.M. Azam and K.A. Sidek Department of Electrical and Computer Engineering, Faculty of Engineering, International Islamic University

More information

Hands on Sports Therapy KNOWLEDGE REVIEW QUESTIONS 2004 Thomson Learning It can help to shape a basic fitness training programme

Hands on Sports Therapy KNOWLEDGE REVIEW QUESTIONS 2004 Thomson Learning It can help to shape a basic fitness training programme Hands on Sports Therapy KNOWLEDGE REVIEW QUESTIONS 2004 Thomson Learning 1 CHAPTER 13 Knowledge Review Q1: Why is fitness testing useful? A1: Fitness testing is useful for various reasons: 1. It can help

More information

Dual channel photoplethysmography studies of cardio-vascular response to the body position changes

Dual channel photoplethysmography studies of cardio-vascular response to the body position changes Dual channel photoplethysmography studies of cardio-vascular response to the body position changes R. Erts, I. Kukulis, J. Spigulis, L. Kere University of Latvia, Raina Blvd. 9, Riga, LV-, Latvia Renars.erts@lu.lv

More information

EXPERIMENTS WITH BLOOD PRESSURE MONITORING USING ECG AND PPG

EXPERIMENTS WITH BLOOD PRESSURE MONITORING USING ECG AND PPG EXPERIMENTS WITH BLOOD PRESSURE MONITORING USING ECG AND D. Špulák 1, R. Čmejla 1, V. Fabián 2 Czech Technical University in Prague, Faculty of Electrical Engineering, 1 Department of Circuit Theory 2

More information

Continuous Monitoring of Blood Pressure Based on Heart Pulse Analysis

Continuous Monitoring of Blood Pressure Based on Heart Pulse Analysis Journal of Physics: Conference Series PAPER OPEN ACCESS Continuous Monitoring of Blood Pressure Based on Heart Pulse Analysis To cite this article: Valerie Tan et al 2018 J. Phys.: Conf. Ser. 1049 012062

More information

Biology 236 Spring 2002 Campos/Wurdak/Fahey Laboratory 4. Cardiovascular and Respiratory Adjustments to Stationary Bicycle Exercise.

Biology 236 Spring 2002 Campos/Wurdak/Fahey Laboratory 4. Cardiovascular and Respiratory Adjustments to Stationary Bicycle Exercise. BACKGROUND: Cardiovascular and Respiratory Adjustments to Stationary Bicycle Exercise. The integration of cardiovascular and respiratory adjustments occurring in response to varying levels of metabolic

More information

Medical Electronics Dr. Neil Townsend Michaelmas Term 2001 ( The story so far.

Medical Electronics Dr. Neil Townsend Michaelmas Term 2001 (  The story so far. Medical Electronics Dr Neil Townsend Michaelmas Term 2001 (wwwrobotsoxacuk/~neil/teaching/lectures/med_elec) Blood Pressure has been measured (in some way) for centuries However, clinical interpretation

More information

Capnography for Pediatric Procedural Sedation Learning Module Last revised: February 18, 2014

Capnography for Pediatric Procedural Sedation Learning Module Last revised: February 18, 2014 Capnography for Pediatric Procedural Sedation Learning Module Last revised: February 18, 2014 Capnography 40 Non-invasive device that continually monitors EtCO 2 While pulse oximetry measures oxygen saturation,

More information

Pulmo Waves Device for respiratory physiotherapy

Pulmo Waves Device for respiratory physiotherapy MADE IN ITALY Pulmo Waves Device for respiratory physiotherapy Respiratory physiotherapy Accumulation of secretions in certain parts of the human respiratory system can take place for different reasons.

More information

Prepared by : Bayan Kaddourah RN,MHM. GICU Clinical Instructor

Prepared by : Bayan Kaddourah RN,MHM. GICU Clinical Instructor Mechanical Ventilation Prepared by : Bayan Kaddourah RN,MHM. GICU Clinical Instructor 1 Definition Is a supportive therapy to facilitate gas exchange. Most ventilatory support requires an artificial airway.

More information

V 185 Continuous sleep-apnea screening in an unattended home-setting

V 185 Continuous sleep-apnea screening in an unattended home-setting S526 V 185 Continuous sleep-apnea screening in an unattended home-setting Simon Annaheim, Laboratory for Biomimetic Membranes and Textiles, Empa, St. Gallen, Schweiz, simon.annaheim@empa.ch Martin Camenzind,

More information

Blood Pressure Determination Using Analysis of Biosignals

Blood Pressure Determination Using Analysis of Biosignals Blood Pressure Determination Using Analysis of Biosignals RADIM ČÍŽ 1, MILAN CHMELAŘ 2 1 Department of Telecommunications Brno University of Technology Purkyňova 118, 612 00 Brno CZECH REPUBLIC cizr@feec.vutbr.cz,

More information

Chapter 9, Part 2. Cardiocirculatory Adjustments to Exercise

Chapter 9, Part 2. Cardiocirculatory Adjustments to Exercise Chapter 9, Part 2 Cardiocirculatory Adjustments to Exercise Electrical Activity of the Heart Contraction of the heart depends on electrical stimulation of the myocardium Impulse is initiated in the right

More information

PRODUCTS FOR THE DIFFICULT AIRWAY. Courtesy of Cook Critical Care

PRODUCTS FOR THE DIFFICULT AIRWAY. Courtesy of Cook Critical Care PRODUCTS FOR THE DIFFICULT AIRWAY Courtesy of Cook Critical Care EMERGENCY CRICOTHYROTOMY Thyroid Cartilage Access Site Cricoid Cartilage Identify the cricothyroid membrane between the cricoid and thyroid

More information

Glabella. Continuously Sensing Blood Pressure Behavior using an Unobtrusive Wearable Device. Christian Holz Edward Wang Microsoft Research

Glabella. Continuously Sensing Blood Pressure Behavior using an Unobtrusive Wearable Device. Christian Holz Edward Wang Microsoft Research Glabella Continuously Sensing Blood Pressure Behavior using an Unobtrusive Wearable Device Christian Holz Edward Wang Microsoft Research Glabella continuously records the pulse at 3 locations, pulse transit

More information

A GUIDE TO OUR NIBP TECHNOLOGY

A GUIDE TO OUR NIBP TECHNOLOGY GE Healthcare THE DINAMAP DIFFERENCE A GUIDE TO OUR NIBP TECHNOLOGY OUR TECHNOLOGICAL ADVANTAGES THE OSCILLOMETRIC METHODOLOGY Oscillometry is the most commonly used means of indirect blood pressure measurement

More information

Physics of the Cardiovascular System

Physics of the Cardiovascular System Dentistry College Medical Physics Physics of the Cardiovascular System The cells of the body act like individual engines. In order for them to function they must have: - 1. Fuel from our food to supply

More information

بسم هللا الرحمن الرحيم

بسم هللا الرحمن الرحيم بسم هللا الرحمن الرحيم Yesterday we spoke of the increased airway resistance and its two examples: 1) emphysema, where we have destruction of the alveolar wall and thus reducing the area available for

More information

PORTO 2 VENT CPAP OS. Operator s Manual. PORTO 2VENT CPAP OS System Operator s Manual Part Number Rev I

PORTO 2 VENT CPAP OS. Operator s Manual. PORTO 2VENT CPAP OS System Operator s Manual Part Number Rev I PORTO 2 VENT CPAP OS Operator s Manual 1 2 TABLE of CONTENTS 1. Introduction 3. Operating Instructions 1a. Definitions 3a. Setting the CPAP Level 1b. General Description 3b. Applying the Breathing Circuit

More information

Cardiovascular Effects of Exercise. Background Cardiac function

Cardiovascular Effects of Exercise. Background Cardiac function Cardiovascular Effects of Exercise In this experiment, you will record an electrocardiogram, or ECG, and finger pulse from a healthy volunteer. You will then compare the ECG and pulse recordings when the

More information

Supplementary Online Content 2

Supplementary Online Content 2 Supplementary Online Content 2 van Meenen DMP, van der Hoeven SM, Binnekade JM, et al. Effect of on demand vs routine nebulization of acetylcysteine with salbutamol on ventilator-free days in intensive

More information

² C Y E N G R E M E ssignac Cardiac Arrest Resuscitation Device uob

² C Y E N G R E M E ssignac Cardiac Arrest Resuscitation Device uob E M E R G E N C Y Boussignac Cardiac Arrest Resuscitation Device ² What is b-card? b-card Boussignac Cardiac Arrest Resuscitation Device has been designed specifically for the treatment of cardiac arrest.

More information

a central pulse located at the apex of the heart Apical pulse Apical-radial pulse a complete absence of respirations Apnea

a central pulse located at the apex of the heart Apical pulse Apical-radial pulse a complete absence of respirations Apnea Afebrile absence of a fever Apical pulse a central pulse located at the apex of the heart Apical-radial pulse measurement of the apical beat and the radial pulse at the same time Apnea a complete absence

More information

Breathing and pulmonary function

Breathing and pulmonary function EXPERIMENTAL PHYSIOLOGY EXPERIMENT 5 Breathing and pulmonary function Ying-ying Chen, PhD Dept. of Physiology, Zhejiang University School of Medicine bchenyy@zju.edu.cn Breathing Exercise 1: Tests of pulmonary

More information

11 th Annual Congress Turkish Thoracic Society. Mechanical Ventilation in Acute Hypoxemic Respiratory Failure

11 th Annual Congress Turkish Thoracic Society. Mechanical Ventilation in Acute Hypoxemic Respiratory Failure 11 th Annual Congress Turkish Thoracic Society Mechanical Ventilation in Acute Hypoxemic Respiratory Failure Lluis Blanch MD PhD Senior Critical Care Center Scientific Director Corporació Parc Taulí Universitat

More information

Capnography. Capnography. Oxygenation. Pulmonary Physiology 4/15/2018. non invasive monitor for ventilation. Edward C. Adlesic, DMD.

Capnography. Capnography. Oxygenation. Pulmonary Physiology 4/15/2018. non invasive monitor for ventilation. Edward C. Adlesic, DMD. Capnography Edward C. Adlesic, DMD University of Pittsburgh School of Dental Medicine 2018 North Carolina Program Capnography non invasive monitor for ventilation measures end tidal CO2 early detection

More information

Test Bank Pilbeam's Mechanical Ventilation Physiological and Clinical Applications 6th Edition Cairo

Test Bank Pilbeam's Mechanical Ventilation Physiological and Clinical Applications 6th Edition Cairo Instant dowload and all chapters Test Bank Pilbeam's Mechanical Ventilation Physiological and Clinical Applications 6th Edition Cairo https://testbanklab.com/download/test-bank-pilbeams-mechanical-ventilation-physiologicalclinical-applications-6th-edition-cairo/

More information

Lumis Tx: the all-in-one hospital ventilation solution

Lumis Tx: the all-in-one hospital ventilation solution Lumis Tx: the all-in-one hospital ventilation solution The Lumis Tx is a multi-purpose non-invasive ventilator that treats the full range of respiratory conditions and is suitable for a variety of hospital

More information

Blood Pressure Laboratory

Blood Pressure Laboratory Introduction The blood that circulates throughout the body maintains a flow and pressure. The nervous system can change the flow and pressure based on the particular needs at a given time. For example,

More information

Bergen Community College Division of Health Professions Department of Respiratory Care Fundamentals of Respiratory Critical Care

Bergen Community College Division of Health Professions Department of Respiratory Care Fundamentals of Respiratory Critical Care Bergen Community College Division of Health Professions Department of Respiratory Care Fundamentals of Respiratory Critical Care Date Revised: January 2015 Course Description Student Learning Objectives:

More information

What is the mechanism of the audible carotid bruit? How does one calculate the velocity of blood flow?

What is the mechanism of the audible carotid bruit? How does one calculate the velocity of blood flow? CASE 8 A 65-year-old man with a history of hypertension and coronary artery disease presents to the emergency center with complaints of left-sided facial numbness and weakness. His blood pressure is normal,

More information

Physiological Measurements Training for Care/Nursing & LD Small Group Home Staff

Physiological Measurements Training for Care/Nursing & LD Small Group Home Staff Physiological Measurements Training for Care/Nursing & LD Small Group Home Staff CONTENTS 1. The National Early Warning Score 2. Respiratory Rate 3. Oxygen Saturations 4. Temperature 5. Blood Pressure

More information

Biomedical Instrumentation D. The Photoplethysmogram

Biomedical Instrumentation D. The Photoplethysmogram Biomedical Instrumentation D. The Photoplethysmogram Dr Gari Clifford Based on slides by Prof. Lionel Tarassenko The need for real-time oxygen saturation monitoring Respiratory failure & pulmonary disease

More information

The Influence of Altered Pulmonarv

The Influence of Altered Pulmonarv The Influence of Altered Pulmonarv J Mechanics on the Adequacy of Controlled Ventilation Peter Hutchin, M.D., and Richard M. Peters, M.D. W ' hereas during spontaneous respiration the individual determines

More information

The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the Edwards PreSep oximetry catheter

The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the Edwards PreSep oximetry catheter 1 2 The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the Edwards PreSep oximetry catheter for continuous central venous oximetry (ScvO2) 3

More information

The Photoplethysmography Imaging Device for Non-contact Monitoring of Sympathetic Blocks

The Photoplethysmography Imaging Device for Non-contact Monitoring of Sympathetic Blocks The Photoplethysmography Imaging Device for Non-contact Monitoring of Sympathetic Blocks U.Rubins 1, A.Miscuks 2, I.Golubovska 2, M.Aron 3 and J.Spigulis 1 1 Institute of Atomic Physics and Spectroscopy,

More information

#6 - Cardiovascular III Heart Sounds, Pulse Rate, Hemoglobin Saturation, and Blood Pressure

#6 - Cardiovascular III Heart Sounds, Pulse Rate, Hemoglobin Saturation, and Blood Pressure #6 - Cardiovascular III Heart Sounds, Pulse Rate, Hemoglobin Saturation, and Blood Pressure Objectives: Observe slide of artery and vein cross-section Auscultate heart sounds using a stethoscope Measure

More information

Oxygenation. Chapter 45. Re'eda Almashagba 1

Oxygenation. Chapter 45. Re'eda Almashagba 1 Oxygenation Chapter 45 Re'eda Almashagba 1 Respiratory Physiology Structure and function Breathing: inspiration, expiration Lung volumes and capacities Pulmonary circulation Respiratory gas exchange: oxygen,

More information

Non-contact Screening System with Two Microwave Radars in the Diagnosis of Sleep Apnea-Hypopnea Syndrome

Non-contact Screening System with Two Microwave Radars in the Diagnosis of Sleep Apnea-Hypopnea Syndrome Medinfo2013 Decision Support Systems and Technologies - II Non-contact Screening System with Two Microwave Radars in the Diagnosis of Sleep Apnea-Hypopnea Syndrome 21 August 2013 M. Kagawa 1, K. Ueki 1,

More information

Comparison of patient spirometry and ventilator spirometry

Comparison of patient spirometry and ventilator spirometry GE Healthcare Comparison of patient spirometry and ventilator spirometry Test results are based on the Master s thesis, Comparison between patient spirometry and ventilator spirometry by Saana Jenu, 2011

More information

Feasibility Evaluation of a Novel Ultrasonic Method for Prosthetic Control ECE-492/3 Senior Design Project Fall 2011

Feasibility Evaluation of a Novel Ultrasonic Method for Prosthetic Control ECE-492/3 Senior Design Project Fall 2011 Feasibility Evaluation of a Novel Ultrasonic Method for Prosthetic Control ECE-492/3 Senior Design Project Fall 2011 Electrical and Computer Engineering Department Volgenau School of Engineering George

More information

Day-to-day management of Tracheostomies & Laryngectomies

Day-to-day management of Tracheostomies & Laryngectomies Humidification It is mandatory that a method of artificial humidification is utilised when a tracheostomy tube is in situ, for people requiring oxygen therapy dry oxygen should never be given to someone

More information

Transcatheter Aortic Valve Implantation Procedure (TAVI)

Transcatheter Aortic Valve Implantation Procedure (TAVI) Page 1 of 5 Procedure (TAVI) Introduction Aortic stenosis (AS) is a common heart valve problem associated with heart failure and death. Surgical valve repair or replacement is recommended if AS patients

More information

FAILURE OF NONINVASIVE VENTILATION FOR DE NOVO ACUTE HYPOXEMIC RESPIRATORY FAILURE: ROLE OF TIDAL VOLUME

FAILURE OF NONINVASIVE VENTILATION FOR DE NOVO ACUTE HYPOXEMIC RESPIRATORY FAILURE: ROLE OF TIDAL VOLUME FAILURE OF NONINVASIVE VENTILATION FOR DE NOVO ACUTE HYPOXEMIC RESPIRATORY FAILURE: ROLE OF TIDAL VOLUME Guillaume CARTEAUX, Teresa MILLÁN-GUILARTE, Nicolas DE PROST, Keyvan RAZAZI, Shariq ABID, Arnaud

More information

Foundations of Critical Care Nursing Course. Tracheostomy Workbook

Foundations of Critical Care Nursing Course. Tracheostomy Workbook Foundations of Critical Care Nursing Course Tracheostomy Workbook 1 Key Reference: Dawson D (2014) Essential principles:trachepstomy care in the adult patient, Nursing in Critical Care, Vol 19, 2 p.63-72.

More information

Chapter 12 - Vital_Signs_and_Monitoring_Devices

Chapter 12 - Vital_Signs_and_Monitoring_Devices Introduction to Emergency Medical Care 1 OBJECTIVES 12.1 Define key terms introduced in this chapter. Slides 13 15, 17, 21 22, 26, 28, 30, 32 33, 35, 44, 47 48, 50, 55, 60 12.2 Identify the vital signs

More information

Cardiovascular Diseases and Diabetes

Cardiovascular Diseases and Diabetes Cardiovascular Diseases and Diabetes LEARNING OBJECTIVES Ø Identify the components of the cardiovascular system and the various types of cardiovascular disease Ø Discuss ways of promoting cardiovascular

More information

ECMO Extracorporeal Membrane Oxygenation

ECMO Extracorporeal Membrane Oxygenation ECMO Extracorporeal Membrane Oxygenation patienteducation.osumc.edu ECMO Table of Contents ECMO: Extracorporeal Membrane Oxygenation... 3 ECMO Treatment... 5 Care Team... 7 Discontinuing ECMO... 8 Notes,

More information

NONINVASIVE CONTINUOUS BLOOD PRESSURE DETERMINATION. D. Barschdorff*, M. Erig*, E. Trowitzsch**

NONINVASIVE CONTINUOUS BLOOD PRESSURE DETERMINATION. D. Barschdorff*, M. Erig*, E. Trowitzsch** NONINVASIVE CONTINUOUS BLOOD PRESSURE DETERMINATION D. Barschdorff*, M. Erig*, E. Trowitzsch** *Institute of Electrical Measurement University of Paderborn, D3398 Paderborn, Germany **Sleep Laboratories

More information

Neonatal Life Support Provider (NLSP) Certification Preparatory Materials

Neonatal Life Support Provider (NLSP) Certification Preparatory Materials Neonatal Life Support Provider (NLSP) Certification Preparatory Materials NEONATAL LIFE SUPPORT PROVIDER (NRP) CERTIFICATION TABLE OF CONTENTS NEONATAL FLOW ALGORITHM.2 INTRODUCTION 3 ANTICIPATION OF RESUSCITATION

More information

TNI 20: Breathe Easier without a Mask

TNI 20: Breathe Easier without a Mask TNI 20: Breathe Easier without a Mask TNI 20 is for many patients a much more comfortable alternative to positive pressure respiration (CPAP) and other methods to treat sleep-related breathing disorders

More information

Laser Doppler Vibrometry for Assessment of Pulse Wave Velocity

Laser Doppler Vibrometry for Assessment of Pulse Wave Velocity Laser Doppler Vibrometry for Assessment of Pulse Wave Velocity Application in an Experimental Setup and in Living Subjects A. Campo, J. Dirckx, Laboratory of Biomedical Physics (Bimef), University of Antwerp

More information

Measuring body temperature, blood pressure, pulse, respiratory rate and oxygen saturation

Measuring body temperature, blood pressure, pulse, respiratory rate and oxygen saturation Vital Signs Measuring body temperature, blood pressure, pulse, respiratory rate and oxygen saturation Aims To ensure that students are able to demonstrate the safe and correct technique for setting up

More information

Estimation of Systolic and Diastolic Pressure using the Pulse Transit Time

Estimation of Systolic and Diastolic Pressure using the Pulse Transit Time Estimation of Systolic and Diastolic Pressure using the Pulse Transit Time Soo-young Ye, Gi-Ryon Kim, Dong-Keun Jung, Seong-wan Baik, and Gye-rok Jeon Abstract In this paper, algorithm estimating the blood

More information

V. Marozas 1, S. Daukantas 1, A. Petrėnas 1, A. Sološenko 1, D. Stankevičius 1, B. Paliakaitė 1, D. Jegelevičius 1, A. Lukoševičius 1, E.

V. Marozas 1, S. Daukantas 1, A. Petrėnas 1, A. Sološenko 1, D. Stankevičius 1, B. Paliakaitė 1, D. Jegelevičius 1, A. Lukoševičius 1, E. V. Marozas 1, S. Daukantas 1, A. Petrėnas 1, A. Sološenko 1, D. Stankevičius 1, B. Paliakaitė 1, D. Jegelevičius 1, A. Lukoševičius 1, E. Kaldoudi 2 1 Biomedical Engineering Institute, Kaunas University

More information

Procedures/Risks: pulmonology, sleep, critical care

Procedures/Risks: pulmonology, sleep, critical care Procedures/Risks: pulmonology, sleep, critical care Bronchoscopy (and bronchoaveolar lavage) Purpose: The purpose of the bronchoscopy is to collect cells and fluid from the lung, so that information can

More information

Precise defect detection with sensor data fusion

Precise defect detection with sensor data fusion Precise defect detection with sensor data fusion Composite Europe 2016 Dipl.-Ing. Philipp Nienheysen Laboratory for Machine Tools and Production Engineering (WZL) of RWTH Aachen University, Germany Chair

More information

Handling Common Problems & Pitfalls During. Oxygen desaturation in patients receiving mechanical ventilation ACUTE SEVERE RESPIRATORY FAILURE

Handling Common Problems & Pitfalls During. Oxygen desaturation in patients receiving mechanical ventilation ACUTE SEVERE RESPIRATORY FAILURE Handling Common Problems & Pitfalls During ACUTE SEVERE RESPIRATORY FAILURE Pravit Jetanachai, MD QSNICH Oxygen desaturation in patients receiving mechanical ventilation Causes of oxygen desaturation 1.

More information

Oxygen Saturation Monitors & Pulse Oximetry. D. J. McMahon rev cewood

Oxygen Saturation Monitors & Pulse Oximetry. D. J. McMahon rev cewood Oxygen Saturation Monitors & Pulse Oximetry D. J. McMahon 141105 rev cewood 2017-11-14 2 3 Key Points Oxygen Saturation Monitors & Pulse Oximetry : Role of hemoglobin in respiration Basic principle of

More information

Thrombolysis Delivery, Care, and Monitoring. 5 Acute Trusts - 6 Primary Care Trusts Ambulance Trust 4 Local Authorities

Thrombolysis Delivery, Care, and Monitoring. 5 Acute Trusts - 6 Primary Care Trusts Ambulance Trust 4 Local Authorities Thrombolysis Delivery, Care, and Monitoring Documentation & Pathways Need to follow locally agreed policies and procedures Follow thrombolysis pathway? Need to complete Sits database Weight Dose matters!

More information

Disclosures. Learning Objectives. Coeditor/author. Associate Science Editor, American Heart Association

Disclosures. Learning Objectives. Coeditor/author. Associate Science Editor, American Heart Association Tracheotomy Challenges for airway specialists Elizabeth H. Sinz, MD Professor of Anesthesiology & Neurosurgery Associate Dean for Clinical Simulation Disclosures Coeditor/author Associate Science Editor,

More information

Sample Case Study. The patient was a 77-year-old female who arrived to the emergency room on

Sample Case Study. The patient was a 77-year-old female who arrived to the emergency room on Sample Case Study The patient was a 77-year-old female who arrived to the emergency room on February 25 th with a chief complaint of shortness of breath and a deteriorating pulmonary status along with

More information

1. When a patient fails to ventilate or oxygenate adequately, the problem is caused by pathophysiological factors such as hyperventilation.

1. When a patient fails to ventilate or oxygenate adequately, the problem is caused by pathophysiological factors such as hyperventilation. Chapter 1: Principles of Mechanical Ventilation TRUE/FALSE 1. When a patient fails to ventilate or oxygenate adequately, the problem is caused by pathophysiological factors such as hyperventilation. F

More information

Small Volume Nebulizer Treatment (Hand-Held)

Small Volume Nebulizer Treatment (Hand-Held) Small Volume Aerosol Treatment Page 1 of 6 Purpose Policy Physician's Order Small Volume Nebulizer Treatment To standardize the delivery of inhalation aerosol drug therapy via small volume (hand-held)

More information

Code Blue III PLUS. Emergency Care Simulators

Code Blue III PLUS. Emergency Care Simulators Code Blue III PLUS Emergency Care Simulators Our Code Blue III system teaches ALS skills using realistic code scenarios. Each step you take is monitored by software providing important feedback, not only

More information

The Respiratory System Structures of the Respiratory System Structures of the Respiratory System Structures of the Respiratory System Nose Sinuses

The Respiratory System Structures of the Respiratory System Structures of the Respiratory System Structures of the Respiratory System Nose Sinuses CH 14 D.E. Human Biology The Respiratory System The Respiratory System OUTLINE: Mechanism of Breathing Transport of Gases between the Lungs and the Cells Respiratory Centers in the Brain Function Provides

More information

Capnography (ILS/ALS)

Capnography (ILS/ALS) Capnography (ILS/ALS) Clinical Indications: 1. Capnography shall be used as soon as possible in conjunction with any airway management adjunct, including endotracheal, Blind Insertion Airway Devices (BIAD)

More information

Dr. Yasser Fathi M.B.B.S, M.Sc, M.D. Anesthesia Consultant, Head of ICU King Saud Hospital, Unaizah

Dr. Yasser Fathi M.B.B.S, M.Sc, M.D. Anesthesia Consultant, Head of ICU King Saud Hospital, Unaizah BY Dr. Yasser Fathi M.B.B.S, M.Sc, M.D Anesthesia Consultant, Head of ICU King Saud Hospital, Unaizah Objectives For Discussion Respiratory Physiology Pulmonary Graphics BIPAP Graphics Trouble Shootings

More information

Biomedical Instrumentation E. Blood Pressure

Biomedical Instrumentation E. Blood Pressure Biomedical Instrumentation E. Blood Pressure Dr Gari Clifford Adapted from slides by Prof. Lionel Tarassenko Blood pressure Blood is pumped around the body by the heart. It makes its way around the body

More information

WHAT IS CTEPH. Helping you understand your type of PH. Provided by Bayer to help education of the PH community

WHAT IS CTEPH. Helping you understand your type of PH. Provided by Bayer to help education of the PH community Educational program by Material endorsed by WHAT IS CTEPH Helping you understand your type of PH Provided by Bayer to help education of the PH community WHAT IS PH? lood travels from your heart to the

More information

Old protocol is top bullet and italicized. Revised protocol is subsequent bullets and color coded:

Old protocol is top bullet and italicized. Revised protocol is subsequent bullets and color coded: Old protocol is top bullet and italicized Revised protocol is subsequent bullets and color coded: RED is a State Change Blue is unique to Suffolk County VI. If patient has not taken aspirin and has no

More information

Circulation And Blood. Circulation And Blood. Circulation And Blood. Circulation And Blood. Blood 10/22/2012

Circulation And Blood. Circulation And Blood. Circulation And Blood. Circulation And Blood. Blood 10/22/2012 Cells in our body build their own membranes and organelles Make their own ATP Assemble their own enzymes and other proteins And may manufacture substances used elsewhere in the body To do these things,

More information

NIV - BI-LEVEL POSITIVE AIRWAY PRESSURE (BIPAP)

NIV - BI-LEVEL POSITIVE AIRWAY PRESSURE (BIPAP) Introduction NIV - BI-LEVEL POSITIVE AIRWAY PRESSURE (BIPAP) Noninvasive ventilation (NIV) is a method of delivering oxygen by positive pressure mask that allows for the prevention or postponement of invasive

More information

JAMES R. KNIGHT

JAMES R. KNIGHT JAMES R. KNIGHT knightjr@ah.org James is currently the supervisor of clinical engineering at Sonora Regional Medical Center. He is the chairman of the CMIA Training & Education Committee. He also develops

More information

Protocol for performing chest clearance techniques by nursing staff

Protocol for performing chest clearance techniques by nursing staff Protocol for performing chest clearance techniques by nursing staff Rationale The main indications for performing chest clearance techniques (CCT) are to assist in the removal of thick, tenacious secretions

More information

Cardiovascular and Respiratory Systems

Cardiovascular and Respiratory Systems Cardiovascular and Respiratory Systems Learning Objectives 1. State the parts of the cardiovascular and respiratory systems and give the functions of each part. 2. Identify the parts of the cardiovascular

More information

Case Report Complete Obstruction of Endotracheal Tube in an Infant with a Retropharyngeal and Anterior Mediastinal Abscess

Case Report Complete Obstruction of Endotracheal Tube in an Infant with a Retropharyngeal and Anterior Mediastinal Abscess Hindawi Case Reports in Pediatrics Volume 2017, Article ID 1848945, 4 pages https://doi.org/10.1155/2017/1848945 Case Report Complete Obstruction of Endotracheal Tube in an Infant with a Retropharyngeal

More information

Cardiac Output Monitoring - 6

Cardiac Output Monitoring - 6 Cardiac Output Monitoring - 6 How to use Wrexham s Cardiac Output Monitors. Wrexham Maelor Critical Care Version 02.05.16 Introduction Types of Devices: NICOM - Cheetah Oesophageal Doppler +/- Pulse Contour

More information

Tracking lung recruitment and regional tidal volume at the bedside. Antonio Pesenti

Tracking lung recruitment and regional tidal volume at the bedside. Antonio Pesenti Tracking lung recruitment and regional tidal volume at the bedside Antonio Pesenti Conflicts of Interest Maquet: Received research support and consultation fees Drager: Received research support and consultation

More information

CHANHASSEN FIRE DEPARTMENT MEDICAL / RESCUE SKILLS

CHANHASSEN FIRE DEPARTMENT MEDICAL / RESCUE SKILLS CHANHASSEN FIRE DEPARTMENT MEDICAL / RESCUE SKILLS PRACTICAL STATIONS CHANHASSEN FIRE DEPARTMENT MEDICAL / RESCUE SKILLS 1. CARDIAC ARREST MANAGEMENT 2. AIRWAY & RESPIRATORY MANAGEMENT 3. SPINAL IMMOBILIZATION

More information

CRITICAL CARE AquaVENT

CRITICAL CARE AquaVENT CRITICAL CARE AquaVENT Heated Breathing Circuits Why Humidification? Normal Respiration During normal respiration, inhaled gases are warmed and moistened as they pass from the upper respiratory tract to

More information

Circulatory, Respiratory, and Excretory Systems

Circulatory, Respiratory, and Excretory Systems 34 Circulatory, Respiratory, and Excretory Systems section 1 Circulatory System Before You Read Press the tips of two fingers to the inside of your wrist, at a point just below your thumb. Can you feel

More information

-Renad Habahbeh. -Shahd Alqudah. - Saleem. 1 P a g e

-Renad Habahbeh. -Shahd Alqudah. - Saleem. 1 P a g e -1 -Renad Habahbeh -Shahd Alqudah - Saleem 1 P a g e Introduction: *Hematology and lymph system (MLS): it is a branch of medicine concerned with the study, diagnosis, prevention and treatment of blood

More information

NBRC Exam RPFT Registry Examination for Advanced Pulmonary Function Technologists Version: 6.0 [ Total Questions: 111 ]

NBRC Exam RPFT Registry Examination for Advanced Pulmonary Function Technologists Version: 6.0 [ Total Questions: 111 ] s@lm@n NBRC Exam RPFT Registry Examination for Advanced Pulmonary Function Technologists Version: 6.0 [ Total Questions: 111 ] https://certkill.com NBRC RPFT : Practice Test Question No : 1 Using a peak

More information

Clinical Research Coordinator Skills Program

Clinical Research Coordinator Skills Program Clinical Research Coordinator Skills Program Vital Signs This Skill Requires Provider direction Standard Precautions Using purell before and after contact with the patient or the patient s environment

More information

WHAT IS. Helping your patients understand their type of PH. Educational program by. Material endorsed by

WHAT IS. Helping your patients understand their type of PH. Educational program by. Material endorsed by Educational program by Material endorsed by WHAT IS CTEPH Helping your patients understand their type of PH Provided by Bayer to help education of the PH community What is ph? B lood travels from your

More information

It is important to point out and frequently remind learners that they are expected to complete ALL aspects of a normal assessment.

It is important to point out and frequently remind learners that they are expected to complete ALL aspects of a normal assessment. Background The purpose of this document is to provide guidelines for faculty on various aspects of patient simulators to be emphasized to learners during orientation. We recommend that every learner be

More information

Tracheostomy and laryngectomy airway emergencies: an overview for medical and nursing staff

Tracheostomy and laryngectomy airway emergencies: an overview for medical and nursing staff 2013 Medical Journal Tracheostomy and laryngectomy airway emergencies: an overview for medical and nursing staff Steven Lobaz 1 and Paul Bush 2 1 ST6 and 2 Consultant Department of Anaesthesia and Intensive

More information

Emergency Medicine High Velocity Nasal Insufflation (Hi-VNI) VAPOTHERM POCKET GUIDE

Emergency Medicine High Velocity Nasal Insufflation (Hi-VNI) VAPOTHERM POCKET GUIDE Emergency Medicine High Velocity Nasal Insufflation (Hi-VNI) VAPOTHERM POCKET GUIDE Indications for Vapotherm High Velocity Nasal Insufflation (Hi-VNI ) administration, the patient should be: Spontaneously

More information

ARDS Management Protocol

ARDS Management Protocol ARDS Management Protocol February 2018 ARDS Criteria Onset Within 1 week of a known clinical insult or new or worsening respiratory symptoms Bilateral opacities not fully explained by effusions, lobar/lung

More information

LUNG NODULE SEGMENTATION IN COMPUTED TOMOGRAPHY IMAGE. Hemahashiny, Ketheesan Department of Physical Science, Vavuniya Campus

LUNG NODULE SEGMENTATION IN COMPUTED TOMOGRAPHY IMAGE. Hemahashiny, Ketheesan Department of Physical Science, Vavuniya Campus LUNG NODULE SEGMENTATION IN COMPUTED TOMOGRAPHY IMAGE Hemahashiny, Ketheesan Department of Physical Science, Vavuniya Campus tketheesan@vau.jfn.ac.lk ABSTRACT: The key process to detect the Lung cancer

More information

UMC HEALTH SYSTEM Lubbock, Texas :

UMC HEALTH SYSTEM Lubbock, Texas : Consent for Commonly Performed Procedures in the Adult Critical Care Units I, the undersigned, understand that the adult intensive and intermediate care units ( critical care units ) are places where seriously

More information

Name Class Date. Bell Diaphragm. Chest piece. Stethoscope

Name Class Date. Bell Diaphragm. Chest piece. Stethoscope Name Class Date Sensing Circulation Exploring the Effects of Exercise on Heart Rate Investigative Lab 30 8 Questions How do the sounds you hear through a stethoscope relate to the stages of a heartbeat?

More information

WILAflow Elite Neonatal Ventilator. Non-invasive treatment for the most delicate patients.

WILAflow Elite Neonatal Ventilator. Non-invasive treatment for the most delicate patients. EN WILAflow Elite Neonatal Ventilator Non-invasive treatment for the most delicate patients. 0197 Infant Ventilation redefined A new generation in Infant Ventilation WILAflow Elite is a microprocessor

More information

NON INVASIVE LIFE SAVERS. Non Invasive Ventilation (NIV)

NON INVASIVE LIFE SAVERS. Non Invasive Ventilation (NIV) Table 1. NIV: Mechanisms Of Action Decreases work of breathing Increases functional residual capacity Recruits collapsed alveoli Improves respiratory gas exchange Reverses hypoventilation Maintains upper

More information

Food Intake Detection from Inertial Sensors using LSTM Networks

Food Intake Detection from Inertial Sensors using LSTM Networks Food Intake Detection from Inertial Sensors using LSTM Networks Kyritsis Konstantinos Diou Christos Delopoulos Anastasios Multimedia Understanding Group Information Processing Laboratory Dpt. Electrical

More information

Vital Signs. Vital Signs. Vital Signs

Vital Signs. Vital Signs. Vital Signs Vital Signs Vital Signs Why do vital signs? Determine relative status of vital organs Establish baseline Monitor response to Rx, meds Observe trends Determine need for further evaluation, Rx, intervention

More information