The Diabetes Control and Complications. Research CMAJ

Size: px
Start display at page:

Download "The Diabetes Control and Complications. Research CMAJ"

Transcription

1 CMAJ Research Glucose-responsive insulin and glucagon delivery (dual-hormone artificial pancreas) in adults with type 1 diabetes: a randomized crossover controlled trial Ahmad Haidar Eng MScA, Laurent Legault MD, Maryse Dallaire RN, Ammar Alkhateeb MD, Adèle Coriati MSc, Virginie Messier MSc, Peiyao Cheng MPH, Maude Millette MD, Benoit Boulet Eng PhD, Rémi Rabasa-Lhoret MD PhD See related commentary by Nathan and Russell on page 285 and at Abstract Background: Most patients with type 1 diabetes do not achieve their glycemic targets. We aimed to assess the efficacy of glucoseresponsive insulin and glucagon closed-loop delivery for controlling glucose levels in adults with type 1 diabetes. Methods: We conducted a randomized crossover trial involving 15 adults with type 1 diabetes, comparing standard insulin-pump therapy with dual-hormone, closed-loop delivery. Patients were admitted twice to a clinical research facility and received, in random order, both treatments. Each 15-hour visit (from 1600 to 0700) included an evening exercise session, followed by a medium-sized meal, a bedtime snack and an overnight stay. During visits that involved closed-loop delivery, basal insulin and glucagon miniboluses were delivered according to recommendations based on glucose sensor readings and a predictive dosing algorithm at 10-minute intervals. During visits involving standard insulin-pump therapy (control visits), patients used conventional treatment. The Diabetes Control and Complications Trial has shown that intensive insulin therapy in type 1 diabetes with the aim of good glycemic control substantially reduces microvascular and macrovascular complications. 1,2 However, despite advances in insulin analogs, insulin pumps and continuous glucosemonitoring systems, glucose control remains problematic, and most patients with type 1 diabetes do not achieve their glycemic targets. 3 Hypoglycemia remains the major barrier to the intensification of insulin therapy. 4 Intensive Results: Dual-hormone closed-loop delivery increased the percentage of time for which patients plasma glucose levels were in the target range (median 70.7% [interquartile range (IQR) 46.1% 88.4%] for closed-loop delivery v. 57.3% [IQR 25.2% 71.8%]for control, p = 0.003) and decreased the percentage of time for which plasma glucose levels were in the low range (bottom of target range [< 4.0 mmol/l], 0.0% [IQR 0.0% 3.0%] for closed-loop delivery v. 10.2% [IQR 0.0% 13.0%] for control, p = 0.01; hypoglycemia threshold [< 3.3 mmol/l], 0.0% [IQR 0.0% 0.0%] for closed-loop delivery v. 2.8% [IQR 0.0% 5.9%] for control, p = 0.006). Eight participants (53%) had at least 1 hypoglycemic event (plasma glucose < 3.0 mmol/l) during standard treatment, compared with just 1 participant (7%) during closed-loop treatment (p = 0.02). Interpretation: Dual-hormone, closed-loop delivery guided by advanced algorithms improved short-term glucose control and reduced the risk of hypoglycemia in a group of 15 adults with type 1 diabetes. Trial registration: ClinicalTrials.gov, no. NCT insulin therapy and lower levels of glycated hemoglobin are unfortunately associated with an increased risk of hypoglycemia. 5 The frequency of patient-reported nonsevere hypoglycemia (blood glucose 3.5 mmol/l, with or without symptoms) is about 2.7 episodes/patient per week, 6 with episodes commonly occuring during the night. In a recent continuous glucose - monitoring trial conducted by the Juvenile Diabetes Research Foundation, 7 hypoglycemia (glucose sensor reading < 3.3 mmol/l) occurred during 8.5% of the nights included in the study Competing interests: Ahmad Haidar and Rémi Rabasa-Lhoret have a patent pending for a closed-loop system dosing algorithm. Laurent Legault has received grant funding from Diabète Québec. Laurent Legault, Benoit Boulet and Rémi Rabasa-Lhoret have received grant funding from the Canadian Diabetes Association. Rémi Rabasa- Lhoret is a consultant for AstraZeneca, Boehringer, Eli Lilly, Merck, Novo- Nordisk and Sanofi-Aventis; he has received grants from AstraZeneca, Eli Lilly, Merck, Novo-Nordisk and Sanofi-Aventis; he has received speaker fees from AstraZeneca, Eli Lilly, Merck and Novo-Nordisk. This article has been peer reviewed. Correspondance to: Ahmad Haidar, ahmad.haidar@mail.mcgill. ca CMAJ DOI: /cmaj Canadian Medical Association or its licensors CMAJ, March 5, 2013, 185(4) 297

2 period, with 47% of those nights involving at least 1 hour of hypoglycemia, 23% involving at least 2 hours, and 11% involving at least 3 hours. Advances in insulin infusion pumps and continuous glucose-monitoring systems could improve glycemic control; 8 however, we still lack the ability to combine these devices in an automated manner. Closed-loop insulin delivery systems (i.e., the artificial pancreas) combine the 2 devices using a mathematical algorithm. 9 These systems might improve glycemic control and reduce the risk of hypoglycemia compared with conventional insulin-pump therapy (i.e., continuous subcutaneous insulin infusion). 10,11 However, a clinically significant number of hypoglycemic events (blood glucose < 3.0 mmol/l) were still reported during tests of closed-loop delivery systems. 10,11 Dual-hormone closed-loop delivery systems have also been proposed to regulate glucose levels. These systems combine insulin delivery with subcutaneous glucagon delivery to further reduce the risk of hypoglycemia However, their potential benefits to improve glycemic control are currently unknown. We sought to determine whether dual-hormone closed-loop delivery, compared with conventional insulin pump therapy, can improve glycemic control and reduce the risk of hypoglycemia in adults with type 1 diabetes. Methods Study design We used an open-label, randomized, crossover design to compare dual-hormone closed-loop delivery with continuous subcutaneous insulin infusion (the control) in adults with type 1 diabetes. Each study visit included an evening exercise session, followed by a meal, a bedtime snack and an overnight stay. The 2 interventions were separated by 7 (interquartile range [IQR] 3 14) days. Participants From February 2011 to January 2012, we enrolled participants from the diabetes clinic at the Institut de Recherches Cliniques de Montréal (Montréal, Quebec). Participants were required to be more than 18 years of age and to have been using an insulin pump for at least 3 months. Patients whose diabetes was poorly controlled (glycated hemoglobin > 10%) were excluded. Other exclusion criteria were applied as detailed in Appendix 1 (available at /lookup /suppl /doi : /cmaj /-/DC1). All participants provided their written informed consent. The study was approved by the research ethics committee at the Institut de Recherches Cliniques de Montréal. Sample size and randomization We anticipated that dual-hormone closed-loop delivery would increase the percentage of time for which plasma glucose concentrations are in the target range by 22% (standard deviation [SD] = 22%). We calculated that 10 participants would provide 80% power at the 5% level of significance to detect such a difference between the 2 interventions. The study included, by its design, an interim assessment to evaluate the appropriateness of the sample size after 6 participants had completed both arms (i.e., a total of 12 completed visits). Subsequently, we adjusted the number needed to enrol to 16 participants, one of whom did not complete the study (Figure 1). We used blocked randomization with an equal allocation ratio to generate allocation sequences. Patients were not blinded to the allocation. Blinding was practically challenging, because patients had to control their glucose levels during control visits, but not during dual-hormone closed-loop delivery. Study protocol Participants arrived at the research facility at about 1500 and received treatment from 1600 until 0700 the next day. The exercise session consisted of a 30-minute workout on a stationary bicycle at 60% VO 2max (each patient s VO 2max had been determined before randomization). At 1730, participants capillary glucose levels were checked using a glucose meter. The exercise session began at 1750 if the glucose level was above 6.0 mmol/l. If the glucose level was below 6.0 mmol/l, 15 g carbohydrate was given orally, and the exercise session began once the glucose level was above 6.0 mmol/l. Each participant received a standardized meal (60 g carbohydrate for females, 80 g carbohydrate for males) at 1920 and a bedtime snack (15 g carbohydrate) at 2200 (for a description of the meal and snack, see Appendix 2, available at /lookup /suppl /doi : /cmaj /-/DC1). Participants were blinded to their plasma and sensor glucose data during both visits and to the hormonal infusions during closed-loop visits. We drew venous blood samples every minutes to determine plasma glucose and insulin levels, and every minutes to determine plasma glucagon levels. Plasma glucose levels were measured using a YSI2300 STAT Plus Analyzer (Yellow Springs, Ohio). Plasma insulin and glucagon were measured using an immunoassay (Millipore, Billerica, Massachusetts). 298 CMAJ, March 5, 2013, 185(4)

3 During visits involving dual -hormone closedloop delivery, glucose levels were regulated using variable subcutaneous insulin delivery combined with subcutaneous miniboluses of glucagon. Insulin aspart and recombinant glucagon were delivered by 2 infusion pumps (MiniMed Paradigm Veo, Medtronic, Northridge, California), according to recommendations, at 10-minute intervals and as determined by our dosing algorithm (Appendix 2). At the time of the evening meal, we entered the meal s carbohydrate content into the algorithm to calculate the prandial bolus. Insulin and glucagon delivery was otherwise based only on readings from a continuous glucose sensor measuring interstitial glucose (Sofsensor, Medtronic). Every 10 minutes, we manually entered the real-time readings from the continuous glucose sensor into a computer that calculated insulin and glucagon delivery. We then manually gave the insulin and glucagon through the infusion pumps. We used a single sensor that we calibrated using finger-stick capillary glucose measurements. We did not recalibrate or replace the sensor in the event of suboptimal accuracy, and we always ad hered to the dosing algorithm. Approached and assessed for eligibility n = 19 Excluded Refused to participate n = 2 VO 2max assessment n = 17 7 (IQR 6 8) d Excluded Unable to complete assessment n = 1 R Visit 1 Continuous subcutaneous insulin infusion n = 8 Visit 1 Dual-hormone, closed-loop delivery n = 8 7 (IQR 3 14) d 7 (IQR 3 14) d Visit 2 Dual-hormone, closed-loop delivery n = 8 Visit 2 Continuous subcutaneous insulin infusion n = 8 Excluded Cannulation problem n = 1 Participants who completed study n = 15 Figure 1: Flow of participants through the crossover study, showing the crossover in therapies between visits 1 and 2. The crossed-over streams are shown in parallel on each side of the flow chart. IQR = interquartile range, VO 2max = maximum oxygen uptake. CMAJ, March 5, 2013, 185(4) 299

4 A 14 Meal Snack Closed-loop delivery Control Concentration, mmol/l B Closed-loop delivery Control Insulin infusion, U/h C 0.20 Glucagon delivered, mg Time of day Figure 2: Profiles (medians and interquartile ranges) of (A) plasma glucose concentration and (B) basal insulin infusion with dual-hormone closed-loop delivery and continuous subcutaneous insulin infusion. (C) The histogram of glucagon delivery during closed-loop delivery. 300 CMAJ, March 5, 2013, 185(4)

5 During control visits, participants received continuous subcutaneous insulin infusion. Parti - cipants had access to their finger-stick glucose measurements, knew the carbohydrate content of their meal and snack, and consequently adjusted their insulin delivery (including temporary basal and correction boluses) as per their standard practice. Outcomes measures Our primary outcome was the percentage of time for which plasma glucose concentrations were in the target range during each 15-hour visit ( mmol/l between the hours of 1600 and 2300, and mmol/l between the hours of 2300 and 0700). Our secondary outcomes were the percentage of time spent below the target range, the percentage of time spent above the target range, the total amount of insulin delivered, the standard deviation of plasma glucose concentrations and the number of parti cipants with hypoglycemic events (blood glucose < 3.0 mmol/l). Statistical analysis For each continuous outcome, we used a repeated-measures regression model based on the ranked normal transformation (with the exception of mean glucose, which was not transformed) to compare the 2 treatments, adjusting for the starting glucose level and the period effect. We used the McNemar test to compare rates of hypoglycemia. Results Fifteen participants completed the study and were included in our analysis (Figure 1). The CMAJ, March 5, 2013, 185(4) 301

6 characteristics of the participants are listed in Appendix 3 (available at /lookup /suppl /doi : /cmaj / -/DC1). Dual-hormone closed-loop delivery generally reduced interpatient variability in plasma glucose concentrations (Figure 2). The median and IQRs of participants glucose levels during control visits suggest that, during the night, 25% of the participants had glucose levels below 4.0 mmol/l at about 0100, and 25% of the participants had glucose levels above 10.0 mmol/l at about 0530 (Figure 2). During visits involving closed-loop delivery, participants plasma glucose levels were in the target range a median of 70.7% of the time (IQR 46.4% 88.4%), compared with 57.3% of the time (IQR 25.2% 71.8%) during control visits (p = 0.003; Table 1). Compared with conventional treatment, closed-loop delivery significantly decreased the percentage of time spent in hypoglycemia (0.0% v. 10.2% for plasma glucose levels < 4.0 mmol/l, and 0.0% v. 2.8% for plasma glucose levels < 3.3 mmol/l; Table 1). The percentage of time spent in the target range for plasma glucose levels during the night was higher for closed-loop delivery than for conventional treatment (72.0% v. 45.8%, repeated measures analysis p = 0.07, Table 1). Closedloop delivery also reduced nocturnal hypoglycemia. When samples collected during the Table 2: Rates of hypoglycemia and nocturnal plasma glucose concentrations among 15 patients with type 1 diabetes during each intervention Outcome Intervention, no. (%) Dual-hormone closed-loop delivery n = 15 Continuous subcutaneous insulin infusion n = 15 p value* Patients with at least 1 1 (7) 8 (53) 0.02 hypoglycemic event Patients with at least 1 0 (0) 5 (33) 0.07 nocturnal hypoglycemic event Patients with at least 1 1 (7) 2 (13) 1.0 exercise-induced hypoglycemic event Nocturnal plasma glucose n = 363 n = 367 measurements < 4.0 mmol/l 2 (0.5) 45 (12.3) < 3.3 mmol/l 0 (0.0) 13 (3.5) < 3.0 mmol/l 0 (0.0) 9 (2.5) *McNemar test. Defined as at least 1 measurement of plasma glucose concentration < 3.0 mmol/l, which was treated by oral carbohydrate. Between the hours of 2300 and From start of exercise to Measurements were taken at 20-min intervals. night were combined (Table 2), 45 (12.3%) of the measurements of plasma glucose concentration were below 4.0 mmol/l during control visits, compared with only 2 measurements (0.5%) during closed-loop delivery, a more than 20-fold reduction. The total amounts of insulin delivered did not differ between the 2 interventions (Table 1). Prandial boluses, as determined using our algorithm, were lower by 0.9 (IQR ) units during visits involving closed-loop delivery, compared with patient-determined boluses during control visits (repeated measures analysis p = 0.004). Prandial boluses were given at the start of meal ingestion on both visits. Hypoglycemic events We saw no adverse events other than hypoglycemia. Eight participants (53%) had at least 1 hypoglycemic event (plasma glucose concentration < 3.0 mmol/l) during a control visit, whereas only 1 participant (7%) had at least 1 hypoglycemic event during dual -hormone closed-loop delivery (McNemar test p = 0.02), an 8-fold difference. For 7 participants (47%), hypoglycemic events occurred only during the control visit; no participants had hypoglycemic events only during closed-loop delivery, 1 parti - ci pant (7%) had hypoglycemic events during both visits, and 7 participants (47%) had no hyperglycemic events during either visit (data not shown). For the participant with hypoglycemia during both visits, 3 episodes occurred during the control visit and 2 episodes occurred during closed-loop delivery (data not shown). We saw a total of 12 hypoglycemic events during control visits and 2 events during closed-loop delivery (data not shown). We treated each event with 15 g oral carbohydrate. A second treatment was necessary for 4 events (all during control visits), 1 of which required a third treatment. Characteristics of glucagon delivery Total glucagon delivery during closed-loop delivery was (IQR ) mg per visit (Appendix 3), resulting in a modest increase in mean plasma glucagon level (66 v. 56 pg/ml, repeated measures analysis p = 0.01; Table 1). Glucagon was delivered intermittently (average of 1 minibolus every 3.6 h) and in small amounts (0.014 [IQR ] mg/bolus). Insulin delivery was suspended for 40 (± 35) minutes before delivering glucagon but was not enough to prevent falling glucose levels (Figure 3). Glucagon delivery was used to prevent impending hypoglycemia rather than to treat it. The median plasma glucose level was 4.9 mmol/l and descending at a rate of 0.8 mmol/l per hour 302 CMAJ, March 5, 2013, 185(4)

7 at the time of glucagon delivery, and 5.3 mmol/l and ascending at a rate of 1.5 mmol/l per hour 20 minutes after glucagon delivery (Figure 3). None of the participants reported any gastrointestinal symptoms after receiving glucagon boluses. Of the 61 glucagon miniboluses delivered, 24 (40%) were given nocturnally. Insulin delivery before a glucagon minibolus was suspended for a longer time during the night compared with during the overall study period (57 min v. 40 min). This was because, in case of impending hypoglycemia, glucose levels fell less rapidly during the night than during exercise or the late postprandial period. Sensor performance Sensor performance was adequate for closedloop delivery (relative absolute error 12.9% [IQR 6.5% 21.6%]). However, sensor readings often showed concentrations in the target range when plasma glucose was actually in the hyperglycemic range (sensor under-read by 1.07 [IQR ] mmol/l in the hyperglycemic range [plasma glucose > 8.0 mmol/l]; n = 555). This may explain why the percentage of time spent above the target range was not reduced with closed-loop delivery. During closed-loop delivery, sensing errors possibly increased time spent above the target range by 10% 15% (the median percentage of time spent above the target range was 16% [data not shown] when calculated using sensor data, compared with 29% when calculated using plasma glucose measurements [Table 1]). We did not see sensor underreading in the nonhyperglycemic range (0.18 [IQR 0.70 to 0.85] mmol/l [plasma glucose 8.0 mmol/l]; n = 828). Improvements in sensor performance will likely further improve closedloop delivery. Interpretation Dual-hormone closed-loop delivery improved glucose control and reduced the risk of hypoglycemia in our 15 participants, as compared with continuous subcutaneous insulin infusion. Rates of hypoglycemia (plasma glucose concentration < 3.0 mmol/l) were reduced, with no increased risk of hyperglycemia. Hypoglycemia is common in type 1 diabetes, and its management is difficult because patients might not show symptoms. Hypoglycemia remains underestimated, with up to 60% of events going unrecognized. 15 Recurrent hypoglycemia leading to hypoglycemia unawareness emphasizes the need for improved prevention and mitigation strategies. 4 Hypoglycemia alarms are now an essential part of continuous glucose sensors, but they are of limited benefit during the night. 16 Hypoglycemia is feared by most patients and remains the most common adverse effect of insulin therapy. Dual-hormone closed-loop delivery appears to have the potential to reduce the risk of hypoglycemia. Patients with hypoglycemia unawareness might benefit the most from this technology. However, this potential should be confirmed with larger and longer studies in an outpatient setting. Plasma glucose concentration, mmol/l Glucose levels Glucagon bolus Insulin delivery Time (min) Insulin (U/h) and glucagon delivery (U) Figure 3: Profiles (medians and interquartile ranges) of plasma glucose concentration and basal insulin infusion before and after receipt of glucagon bolus (n = 61 boluses). CMAJ, March 5, 2013, 185(4) 303

8 Mean plasma glucose levels did not differ between the 2 treatments. However, betweenpatient variability in mean plasma glucose level was 50% higher during control visits than during closed-loop delivery, suggesting higher dispersion of individual mean plasma glucose levels. Hypoglycemia was common during control visits and therefore reduced mean glucose levels, whereas closed-loop delivery eliminated most hypoglycemia without increasing mean glucose levels. This trend is also seen in the glucose profiles shown in Figure 1. Comparison with other studies Recent randomized trials involving adults with type 1 diabetes have shown that overnight closedloop insulin delivery increases the percentage of time for which plasma glucose levels are in the target range and decreases the time spent in the hypoglycemic range compared with conventional treatment. 10,11 However, the reductions in time spent in the hypoglycemic range and numbers of patients with hypoglycemic events were not as remarkable as those in our study. Although there have been previous studies of closed-loop insulin delivery 17,18 and closed-loop insulin and glucagon delivery 13,14,19 involving adults with type 1 diabetes, they did not have a randomized study design to make comparisons with conventional therapy. Furthermore, most of these studies have assessed the performance of the dosing algorithm rather than the clinical application of the whole system. Instead of a single glucose sensor, infusions were based on venous glucose 14 or multiple sensors, 13 and were sometimes overridden by an attending physician. 13,17 Moreover, the glucose sensor was calibrated using referencequality venous plasma glucose 10,17,19 instead of capillary finger-stick measurements, potentially overestimating the benefits of closed-loop delivery. These issues may limit the application of the results of such studies in clinical practice. Our study avoided these shortcomings. Limitations Our study was powered using data from other studies of closed-loop delivery; 11,13 despite having statistical significance in most outcomes, our study was limited by its small sample size. An additional limitation to our study was the absence of allocation blinding, but blinding participants to the interventions was practically challenging. Finally, current glucagon formulations are unlikely to be suitable for extended pump use, because they are unstable at room temperature after reconstitution. Research is underway to develop more stable formulations of the hormone. 20,21 Conclusion Compared with conventional therapy, dual - hormone closed-loop delivery improved shortterm glycemic control and reduced the risk of hypoglycemia among 15 adults with type 1 diabetes. Closed-loop delivery systems have the potential to substantially improve the management of diabetes and the safety of patients. These systems will probably be introduced gradually to clinical practice, with early generations focusing on overnight glucose control and using insulin alone. Their limitations and benefits will be elucidated, and their performance will be perfected over time. References 1. The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. The Diabetes Control and Complications Trial Research Group. N Engl J Med 1993;329: Nathan DM, Cleary PA, Backlund JY, et al. Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes. N Engl J Med 2005;353: Writing Team for the Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications Research Group. Sustained effect of intensive treatment of type 1 diabetes mellitus on development and progression of diabetic nephropathy: the Epidemiology of Diabetes Interventions and Complications (EDIC) study. JAMA 2003;290: Cryer PE. Hypoglycaemia: the limiting factor in the glycaemic management of type I and type II diabetes. Diabetologia 2002; 45: Hypoglycemia in the Diabetes Control and Complications Trial; The Diabetes Control and Complications Trial Research Group. Diabetes 1997;46: Choudhary P, Geddes J, Freeman JV, et al. Frequency of biochemical hypoglycaemia in adults with type 1 diabetes with and without impaired awareness of hypoglycaemia: no identifiable differences using continuous glucose monitoring. Diabet Med 2010;27: Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group. Prolonged nocturnal hypoglycemia is common during 12 months of continuous glucose monitoring in children and adults with type 1 diabetes. Diabetes Care 2010; 33: Bergenstal RM, Tamborlane WV, Ahmann A, et al. Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes. N Engl J Med 2010;363: Hovorka R. Closed-loop insulin delivery: from bench to clinical practice. Nat Rev Endocrinol 2011;7: Breton M, Farret A, Bruttomesso D, et al. Fully integrated artificial pancreas in type 1 diabetes: modular closed-loop glucose control maintains near normoglycemia. Diabetes 2012;61: Hovorka R, Kumareswaran K, Harris J, et al. Overnight closed loop insulin delivery (artificial pancreas) in adults with type 1 diabetes: crossover randomised controlled studies. BMJ 2011; 342: d Shichiri M, Kawamori R, Yamasaki Y, et al. Wearable artificial endocrine pancreas with needle-type glucose sensor. Lancet 1982; 2: Castle JR, Engle JM, El Youssef J, et al. Novel use of glucagon in a closed-loop system for prevention of hypoglycemia in type 1 diabetes. Diabetes Care 2010;33: El-Khatib FH, Russell SJ, Nathan DM, et al. A bihormonal closed-loop artificial pancreas for type 1 diabetes. Sci Transl Med. 2010;2:27ra Chico A, Vidal-Rios P, Subira M, et al. The continuous glucose monitoring system is useful for detecting unrecognized hypoglycemias in patients with type 1 and type 2 diabetes but is not better than frequent capillary glucose measurements for improving metabolic control. Diabetes Care 2003;26: Buckingham B, Block J, Burdick J, et al. Response to nocturnal alarms using a real-time glucose sensor. Diabetes Technol Ther 2005;7: Kovatchev B, Cobelli C, Renard E, et al. Multinational study of subcutaneous model-predictive closed-loop control in type 1 diabetes mellitus: summary of the results. J Diabetes Sci Technol 2010;4: CMAJ, March 5, 2013, 185(4)

9 Research 18. Atlas E, Nimri R, Miller S, et al. MD-logic artificial pancreas system: a pilot study in adults with type 1 diabetes. Diabetes Care 2010;33: Russell SJ, El-Khatib FH, Nathan DM, et al. Blood glucose control in type 1 diabetes with a bihormonal bionic endocrine pancreas. Diabetes Care 2012;35: Steiner SS, Li M, Hauser R, et al. Stabilized glucagon formulation for bihormonal pump use. J Diabetes Sci Technol 2010; 4: Ward WK, Massoud RG, Szybala CJ, et al. In vitro and in vivo evaluation of native glucagon and glucagon analog (MAR-D28) during aging: lack of cytotoxicity and preservation of hyperglycemic effect. J Diabetes Sci Technol 2010;4: Affiliations: From the Institut de Recherches Cliniques de Montréal (Haidar, Dallaire, Alkhateeb, Coriati, Messier, Rabasa-Lhoret); the Centre for Intelligent Machines, McGill University (Haidar, Boulet); the Montréal Children s Hospital (Legault, Millette); the Nutrition Department (Rabasa-Lhoret), Université de Montréal; and the Endocrinology Division (Rabasa-Lhoret), Montreal University Hospital, Montréal, Que.; and the Jaeb Center for Health Research (Cheng), Tampa, Fla. Contributors: Ahmad Haidar and Rémi Rabasa-Lhoret coordinated the study. Ahmad Haider, Rémi Rabasa-Lhoret, Laurent Legault, Benoit Boulet and Ammar Alkhateeb designed the study. Ahmad Haider, Maryse Dallaire, Rémi Rabasa-Lhoret, Laurent Legault, Adèle Coriati and Ammar Alkhateeb conducted the study. Ahmad Haidar designed and implemented the dosing algorithm. Ahmad Haider, Ammar Alkhateeb, Virginie Messier, Peiyao Cheng and Maude Millette analyzed the data. All of the authors contributed to the interpretation of the results, the writing and critical review of the manuscript, and the approval of final version submitted for publication. Funding: This study was supported by Diabète Québec, the Canadian Diabetes Association (operating grant no. OG RR) and the J.-A. De Sève Chair held by Rémi Rabasa-Lhoret. Medtronic supplied the pumps and sensors used in the study, and read the manuscript before its submission. None of the sponsors had any role in the study design, data collection, data interpretation, or writing of the report. Acknowledgements: The authors thank Annabelle Mathieu, Anne Bossy, Annie Tardif, Corinne Suppere, Sonia Fortin, Diane Mignault, Hortensia Mircescu and Agnès Räkel for their support in conducting the study. REPRINTS We have partnered with Sheridan Press! To purchase commercial article reprints and e-prints or to request a quote, please contact Matt Neiderer Content Sales Sheridan Content Services Publications Mail Agreement no Return undeliverable Canadian addresses to CMA Member Service Centre, 1870 Alta Vista Dr., Ottawa ON K1G 6R7 cma.ca/jpn An open-access journal The official journal of the Society of Rural Physicians of Canada Le journal officiel de la Société de la médecine rurale du Canada VOLUME 17, NO. 4, FALL 2012 VOLUME 17, Nº 4, AUTOMNE 2012 IN THIS ISSUE DANS CE NUMÉRO Joint Position Paper on Rural Maternity Care The Occasional Caudal Epidural Injection The Occasional Epidural Steroid Injection January 2012 Volume 37 Number 1 Does the salience network play a cardinal role in psychosis? An emerging hypothesis of insular dysfunction Effects of early-life adversity on white matter diffusivity changes in patients at risk for major depression Parent-of-origin effects of FAS and PDLIM1 in attention-deficit/ hyperactivity disorder x6265 matt.neiderer@sheridan.com Publications Mail Agreement no USPS # Return undeliverable Canadian addresses to CMA Member Service Centre, 1870 Alta Vista Dr., Ottawa ON K1G 6R7 Canadian Association of General Surgeons Canadian Society for Vascular Surgery Canadian Society of Surgical Oncology Canadian Association of Thoracic Surgeons SPONSORS PARRAINS Vol. 56, No. 1, February/février 2013 cma.ca/cjs Early and late outcomes after cardiac retransplantation Locked plate fixation of the comminuted distal fibula Biological effects of bariatric surgery on obesity-related comorbidities Systematic review of complications after intramedullary fixation for displaced midshaft clavicle fractures Publications Mail Agreement no ; USPS # Return undeliverable Canadian addresses to CMA Member Service Centre, 1870 Alta Vista Drive, Ottawa ON K1G 6R7 FEBRUARY 19, 2013, VOL. 185(3) CMAJ JAMC End-stage renal disease Protecting the kidneys after hypertensive pregnancy Association canadienne des chirurgiens généraux Société canadienne de chirurgie vasculaire Société canadienne d oncologie chirurgicale Association canadienne des chirurgiens thoraciques RESEARCH Delisting routine eye examinations for people with diabetes REVIEW Steroids and acute respiratory distress syndrome PRACTICE Parapneumonic effusion medical knowledge that matters CMAJ, March 5, 2013, 185(4) 305

Artificial Pancreas, shortly close to home? BC Pediatric Diabetes Day, Feb 26, 2016

Artificial Pancreas, shortly close to home? BC Pediatric Diabetes Day, Feb 26, 2016 Artificial Pancreas, shortly close to home? BC Pediatric Diabetes Day, Feb 26, 2016 Rémi Rabasa- Lhoret, M.D. (Endocrinology), Ph.D. CSPQ Director Pla:orm for Research in Obesity, Metabolism and Diabetes

More information

Artificial Pancreas Device Systems. Populations Interventions Comparators Outcomes Individuals: With type 1 diabetes

Artificial Pancreas Device Systems. Populations Interventions Comparators Outcomes Individuals: With type 1 diabetes Protocol Artificial Pancreas Device Systems Medical Benefit Effective Date: 07/01/18 Next Review Date: 01/20 Preauthorization Yes Review Dates: 03/15, 03/16, 03/17, 01/18, 05/18, 01/19 Preauthorization

More information

[Frida Svendsen and Jennifer Southern] University of Oxford

[Frida Svendsen and Jennifer Southern] University of Oxford In adolescents with poorly controlled type 1 diabetes mellitus, could a bionic, bihormonal pancreas provide better blood glucose control than continuous subcutaneous insulin infusion therapy? [Frida Svendsen

More information

Artificial Pancreas Device Systems. Populations Interventions Comparators Outcomes. pump. pump

Artificial Pancreas Device Systems. Populations Interventions Comparators Outcomes. pump. pump Protocol Artificial Pancreas Device Systems (10130) Medical Benefit Effective Date: 04/01/18 Next Review Date: 01/19 Preauthorization Yes Review Dates: 03/15, 03/16, 03/17, 01/18 Preauthorization is required.

More information

Artificial Pancreas Device System (APDS)

Artificial Pancreas Device System (APDS) Medical Policy Manual Durable Medical Equipment, Policy No. 77 Artificial Pancreas Device System (APDS) Next Review: October 2019 Last Review: October 2018 Effective: November 1, 2018 IMPORTANT REMINDER

More information

The artificial pancreas: the next step in connectivity and digital treatment of type 1 diabetes

The artificial pancreas: the next step in connectivity and digital treatment of type 1 diabetes The artificial pancreas: the next step in connectivity and digital treatment of type 1 diabetes Roman Hovorka PhD FMedSci University of Cambridge, UK Duality of interest declaration Advisory Panel: Research

More information

Presented by Dr. Bruce Perkins, MD MPH Dr. Michael Riddell, PhD

Presented by Dr. Bruce Perkins, MD MPH Dr. Michael Riddell, PhD Type 1 Diabetes and Exercise: Optimizing the Medtronic MiniMed Veo Insulin Pump and Continuous Glucose Monitoring (CGM) for Better Glucose Control 1,2 for Healthcare Professionals Presented by Dr. Bruce

More information

Diabetes Management: Current High Tech Innovations

Diabetes Management: Current High Tech Innovations Diabetes Management: Current High Tech Innovations How Far We ve Come in the Last 40 Years William V. Tamborlane, MD Department of Pediatrics Yale School of Medicine Disclosures I am a consultant for:

More information

PREVENTION OF NOCTURNAL HYPOGLYCEMIA USING PREDICTIVE LOW GLUCOSE SUSPEND (PLGS)

PREVENTION OF NOCTURNAL HYPOGLYCEMIA USING PREDICTIVE LOW GLUCOSE SUSPEND (PLGS) PREVENTION OF NOCTURNAL HYPOGLYCEMIA USING PREDICTIVE LOW GLUCOSE SUSPEND (PLGS) Pathways for Future Treatment and Management of Diabetes H. Peter Chase, MD Carousel of Hope Symposium Beverly Hilton, Beverly

More information

Supplementary Appendix

Supplementary Appendix Supplementary Appendix This appendix has been provided by the authors to give readers additional information about their work. Supplement to: Phillip M, Battelino T, Atlas E, et al. Nocturnal glucose control

More information

Research Proposal. 1. Background and Rationale

Research Proposal. 1. Background and Rationale 1. Background and Rationale Insulin is secreted by the pancreatic beta cells and reduces blood glucose concentration (1). Glucagon is secreted by the pancreatic alpha cells and increases glucose concentration.

More information

Artificial Pancreas Device Systems

Artificial Pancreas Device Systems Artificial Pancreas Device Systems Policy Number: 1.01.30 Last Review: 1/2019 Origination: 1/2017 Next Review: 1/2020 Policy Blue Cross and Blue Shield of Kansas City (Blue KC) will provide coverage for

More information

ARTICLE. Diabetologia (2016) 59: DOI /s

ARTICLE. Diabetologia (2016) 59: DOI /s Diabetologia (2016) 59:2561 2571 DOI 10.1007/s00125-016-4107-0 ARTICLE Efficacy of single-hormone and dual-hormone artificial pancreas during continuous and interval exercise in adult patients with type

More information

Medical Policy. MP Artificial Pancreas Device Systems

Medical Policy. MP Artificial Pancreas Device Systems Medical Policy MP 1.01.30 BCBSA Ref. Policy: 1.01.30 Last Review: 01/30/2018 Effective Date: 04/01/2018 Section: Durable Medical Equipment Related Policies 1.01.20 Continuous or Intermittent Monitoring

More information

Advances in Technology in the Treatment of Diabetes Mellitus 2017 How far have we come-how far are we going? Is there a final frontier?

Advances in Technology in the Treatment of Diabetes Mellitus 2017 How far have we come-how far are we going? Is there a final frontier? Advances in Technology in the Treatment of Diabetes Mellitus 2017 How far have we come-how far are we going? Is there a final frontier? Alan B Schorr DO FAAIM FACE www.sugardoc.com abs@sugardoc.com Disclosures

More information

What is a CGM? (Continuous Glucose Monitor) The Bionic Pancreas Is Coming

What is a CGM? (Continuous Glucose Monitor) The Bionic Pancreas Is Coming The Bionic Pancreas Is Coming Montana Diabetes Professional Conference October 23, 2014 H. Peter Chase, MD Professor of Pediatrics University of Colorado Barbara Davis Center Stanford: Bruce Buckingham,

More information

Hypoglycemia a barrier to normoglycemia Are long acting analogues and pumps the answer to the barrier??

Hypoglycemia a barrier to normoglycemia Are long acting analogues and pumps the answer to the barrier?? Hypoglycemia a barrier to normoglycemia Are long acting analogues and pumps the answer to the barrier?? Moshe Phillip Institute of Endocrinology and Diabetes National Center of Childhood Diabetes Schneider

More information

Preventing Hypoglycemia Using Predictive Alarm Algorithms and Insulin Pump Suspension

Preventing Hypoglycemia Using Predictive Alarm Algorithms and Insulin Pump Suspension DIABETES TECHNOLOGY & THERAPEUTICS Volume 11, Number 2, 29 Mary Ann Liebert, Inc. DOI: 1.189/dia.28.32 Preventing Hypoglycemia Using Predictive Alarm Algorithms and Insulin Pump Suspension Bruce Buckingham,

More information

Clinical Policy Title: Artificial pancreas device system

Clinical Policy Title: Artificial pancreas device system Clinical Policy Title: Artificial pancreas device system Clinical Policy Number: 08.02.07 Effective Date: April 1, 2016 Initial Review Date: November 18, 2015 Most Recent Review Date: February 6, 2018

More information

Bringing closed-loop home: recent advances in closed-loop insulin delivery

Bringing closed-loop home: recent advances in closed-loop insulin delivery REVIEW C URRENT OPINION Bringing closed-loop home: recent advances in closed-loop insulin delivery Hood Thabit and Roman Hovorka Purpose of review To highlight the recent advances in closed-loop research,

More information

Outpatient Glycemic Control with a Bionic Pancreas in Type 1 Diabetes

Outpatient Glycemic Control with a Bionic Pancreas in Type 1 Diabetes original article Outpatient Glycemic with a Bionic Pancreas in Type 1 Diabetes Steven J. Russell, M.D., Ph.D., Firas H. El-Khatib, Ph.D., Manasi Sinha, M.D., M.P.H., Kendra L. Magyar, M.S.N., N.P., Katherine

More information

INSULIN INITIATION AND INTENSIFICATION WITH A FOCUS ON HYPOGLYCEMIA REDUCTION

INSULIN INITIATION AND INTENSIFICATION WITH A FOCUS ON HYPOGLYCEMIA REDUCTION INSULIN INITIATION AND INTENSIFICATION WITH A FOCUS ON HYPOGLYCEMIA REDUCTION Jaiwant Rangi, MD, FACE Nov 10 th 2018 DISCLOSURES Speaker Novo Nordisk Sanofi-Aventis Boheringer Ingleheim Merck Abbvie Abbott

More information

Control of Glycemic Variability for Reducing Hypoglycemia Jae Hyeon Kim

Control of Glycemic Variability for Reducing Hypoglycemia Jae Hyeon Kim Control of Glycemic Variability for Reducing Hypoglycemia Jae Hyeon Kim Division of Endocrinology and Metabolism, Samsung Medical Center, Sungkyunkwan University School of Medicine Conflict of interest

More information

What is the role of insulin pumps in the modern day care of patients with Type 1 diabetes?

What is the role of insulin pumps in the modern day care of patients with Type 1 diabetes? What is the role of insulin pumps in the modern day care of patients with Type 1 diabetes? Dr. Fiona Wotherspoon Consultant in Diabetes and Endocrinology Dorset County Hospital Fiona.Wotherspoon@dchft.nhs.uk

More information

Hope for an ARTIFICIAL PANCREAS

Hope for an ARTIFICIAL PANCREAS FEATURE Hope for an ARTIFICIAL PANCREAS By Dana VanBuecken Progress is being made to develop a continuous glucose monitor that works with an insulin pump to replace the body s insulin-producing cells.

More information

NEWS BRIEFING Advances in Technology. moderated by: Irl Hirsch, MD University of Washington Medical Center

NEWS BRIEFING Advances in Technology. moderated by: Irl Hirsch, MD University of Washington Medical Center NEWS BRIEFING Advances in Technology moderated by: Irl Hirsch, MD University of Washington Medical Center 1 EMBARGO POLICY All recordings are for personal use only and not for rebroadcast online or in

More information

Today s Goals 10/6/2017. New Frontiers in Diabetes Technology. Disclosures

Today s Goals 10/6/2017. New Frontiers in Diabetes Technology. Disclosures New Frontiers in Diabetes Technology Marie E. McDonnell, MD Director, Brigham and Women's Diabetes Program Division of Endocrinology, Diabetes and Hypertension Brigham and Women s Hospital Today s Goals

More information

The Artificial Pancreas

The Artificial Pancreas SAGLB.DIA.15.2.87(2). Approved October 215 The Artificial Pancreas For scientific and medical purposes only The pancreas responds to changes in blood glucose by releasing insulin (β cells) to lower blood

More information

The Realities of Technology in Type 1 Diabetes

The Realities of Technology in Type 1 Diabetes The Realities of Technology in Type 1 Diabetes May 6, 2017 Rosanna Fiallo-scharer, MD Margaret Frederick, RN Disclosures I have no conflicts of interest to disclose I will discuss some unapproved treatments

More information

Report Reference Guide

Report Reference Guide Report Reference Guide How to use this guide Each type of CareLink report and its components are described in the following sections. Report data used to generate the sample reports was from sample patient

More information

Advances in Diabetes Care Technologies

Advances in Diabetes Care Technologies 1979 Advances in Diabetes Care Technologies 2015 Introduction Insulin pump use: ~ 20% - 30% of patients with T1DM < 1% of insulin-treated patients with T2DM 2007 FDA estimates ~375,000 insulin pumps for

More information

JDRF Perspective on Closed Loop

JDRF Perspective on Closed Loop JDRF Perspective on Closed Loop Aaron J. Kowalski, Ph.D. Assistant Vice President Treatment Therapies Juvenile Diabetes Research Foundation International 1 Presenter Disclosure Aaron Kowalski Disclosed

More information

CareLink. software REPORT REFERENCE GUIDE. Management Software for Diabetes

CareLink. software REPORT REFERENCE GUIDE. Management Software for Diabetes CareLink Management Software for Diabetes software REPORT REFERENCE GUIDE How to use this guide Each type of CareLink report and its components are described in the following sections. Report data used

More information

Glucose Outcomes with the In-Home Use of a Hybrid Closed-Loop Insulin Delivery System in Adolescents and Adults with Type 1 Diabetes

Glucose Outcomes with the In-Home Use of a Hybrid Closed-Loop Insulin Delivery System in Adolescents and Adults with Type 1 Diabetes DIABETES TECHNOLOGY & THERAPEUTICS Volume 19, Number 3, 2017 Mary Ann Liebert, Inc. DOI: 10.1089/dia.2016.0421 ORIGINAL ARTICLE Glucose Outcomes with the In-Home Use of a Hybrid Closed-Loop Insulin Delivery

More information

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

Medical Policy An independent licensee of the Blue Cross Blue Shield Association Artificial Pancreas Device Systems Page 1 of 15 Medical Policy An independent licensee of the Blue Cross Blue Shield Association Title: Artificial Pancreas Device Systems Professional Institutional Original

More information

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

Medical Policy An independent licensee of the Blue Cross Blue Shield Association Artificial Pancreas Device Systems Page 1 of 16 Medical Policy An independent licensee of the Blue Cross Blue Shield Association Title: Artificial Pancreas Device Systems Professional Institutional Original

More information

Figure 2.1: Glucose meter

Figure 2.1: Glucose meter CHAPTER TWO: MONITORING TECHNOLOGIES 2.1 Introduction Glucose monitoring is a method of self-testing glucose (blood sugar) levels for the management of diabetes. Traditionally, it involves pricking the

More information

Effect of Insulin Feedback on Closed-Loop Glucose Control: A Crossover Study

Effect of Insulin Feedback on Closed-Loop Glucose Control: A Crossover Study Journal of Diabetes Science and Technology Volume 6, Issue 5, September 2012 Diabetes Technology Society ORIGINAL ARTICLE Effect of Insulin Feedback on Closed-Loop Glucose Control: A Crossover Study Jessica

More information

Insulin Pumps and Glucose Sensors in Diabetes Management

Insulin Pumps and Glucose Sensors in Diabetes Management Diabetes Update+ 2014 Congress Whistler, British Columbia Friday March 21, 2014ǀ 8:15 8:45 am Insulin Pumps and Glucose Sensors in Diabetes Management Bruce A Perkins MD MPH Division of Endocrinology Associate

More information

Diabetes Management Continuous Glucose Monitoring

Diabetes Management Continuous Glucose Monitoring Progress with Closed-loop Systems in Type 1 Diabetes Lalantha Leelarathna 1 and Roman Hovorka 2 1. Clinical Research Associate; 2. Principal Research Associate, Institute of Metabolic Science, University

More information

Reduction in Hypoglycemia and No Increase in A1C with Threshold-Based Sensor-Augmented Pump (SAP) Insulin Suspension: ASPIRE In-Home

Reduction in Hypoglycemia and No Increase in A1C with Threshold-Based Sensor-Augmented Pump (SAP) Insulin Suspension: ASPIRE In-Home Reduction in Hypoglycemia and No Increase in A1C with Threshold-Based Sensor-Augmented Pump (SAP) Insulin Suspension: ASPIRE In-Home Richard M. Bergenstal 1, David C. Klonoff 2, Bruce W. Bode 3, Satish

More information

15 th Annual DAFNE collaborative meeting Tuesday 28 th June 2016

15 th Annual DAFNE collaborative meeting Tuesday 28 th June 2016 15 th Annual DAFNE collaborative meeting Tuesday 28 th June 2016 Sponsored by: Abbott Diabetes Care and Lilly Diabetes Type 1 and exercise Royal Berkshire Hospital Centre for Diabetes and Endocrinology

More information

Continuous or Intermittent Monitoring of Glucose in Interstitial Fluid. Original Policy Date

Continuous or Intermittent Monitoring of Glucose in Interstitial Fluid. Original Policy Date MP 1.01.15 Continuous or Intermittent Monitoring of Glucose in Interstitial Fluid Medical Policy Section Durable Medical Equipment Issue 12:2013 Original Policy Date 12:2013 Last Review Status/Date Reviewed

More information

Home Use of an Artificial Beta Cell in Type 1 Diabetes

Home Use of an Artificial Beta Cell in Type 1 Diabetes The new england journal of medicine Original Article Home Use of an Artificial Beta Cell in Type 1 Diabetes H. Thabit, M. Tauschmann, J.M. Allen, L. Leelarathna, S. Hartnell, M.E. Wilinska, C.L. Acerini,

More information

Reduced Hypoglycemia and Increased Time in Target Using Closed-Loop Insulin Delivery During Nights With or Without Antecedent Afternoon Exercise

Reduced Hypoglycemia and Increased Time in Target Using Closed-Loop Insulin Delivery During Nights With or Without Antecedent Afternoon Exercise Clinical Care/Education/Nutrition/Psychosocial Research O R I G I N A L A R T I C L E Reduced Hypoglycemia and Increased Time in Target Using Closed-Loop Insulin Delivery During Nights With or Without

More information

CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS Annual Meeting HILTON HEAD ISLAND FRIDAY PRESENTATION

CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS Annual Meeting HILTON HEAD ISLAND FRIDAY PRESENTATION CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting HILTON HEAD ISLAND FRIDAY PRESENTATION September 9-11, 2016 ~ Sonesta Resort ~ Hilton Head Island, SC This continuing

More information

Paolo Di Bartolo U.O di Diabetologia Dip. Malattie Digestive & Metaboliche AULS Prov. di Ravenna. Ipoglicemie e Monitoraggio Glicemico

Paolo Di Bartolo U.O di Diabetologia Dip. Malattie Digestive & Metaboliche AULS Prov. di Ravenna. Ipoglicemie e Monitoraggio Glicemico Paolo Di Bartolo U.O di Diabetologia Dip. Malattie Digestive & Metaboliche AULS Prov. di Ravenna Ipoglicemie e Monitoraggio Glicemico Management of Hypoglycaemia.if hypoglycemia is a problem, the principles

More information

Diabetes II Insulin pumps; Continuous glucose monitoring system (CGMS) Ernest Asamoah, MD FACE FACP FRCP (Lond)

Diabetes II Insulin pumps; Continuous glucose monitoring system (CGMS) Ernest Asamoah, MD FACE FACP FRCP (Lond) Diabetes II Insulin pumps; Continuous glucose monitoring system (CGMS) Ernest Asamoah, MD FACE FACP FRCP (Lond) 9501366-011 20110401 Objectives Understand the need for insulin pumps and CGMS in managing

More information

Continuous or Intermittent Glucose Monitoring in Interstitial Fluid

Continuous or Intermittent Glucose Monitoring in Interstitial Fluid Continuous or Intermittent Glucose Monitoring in Interstitial Fluid Policy Number: 1.01.20 Last Review: 9/2014 Origination: 11/2001 Next Review: 9/2015 Policy Blue Cross and Blue Shield of Kansas City

More information

Inpatient Studies of a Kalman-Filter-Based Predictive Pump Shutoff Algorithm

Inpatient Studies of a Kalman-Filter-Based Predictive Pump Shutoff Algorithm Journal of Diabetes Science and Technology Volume 6, Issue 5, September 2012 Diabetes Technology Society ORIGINAL ARTICLE Inpatient Studies of a Kalman-Filter-Based Predictive Pump Shutoff Algorithm Fraser,

More information

Sponsor / Company: Sanofi Drug substance(s): insulin glargine (HOE901) According to template: QSD VERSION N 4.0 (07-JUN-2012) Page 1

Sponsor / Company: Sanofi Drug substance(s): insulin glargine (HOE901) According to template: QSD VERSION N 4.0 (07-JUN-2012) Page 1 These results are supplied for informational purposes only. Prescribing decisions should be made based on the approved package insert in the country of prescription. Sponsor / Company: Sanofi Drug substance(s):

More information

Report Reference Guide. THERAPY MANAGEMENT SOFTWARE FOR DIABETES CareLink Report Reference Guide 1

Report Reference Guide. THERAPY MANAGEMENT SOFTWARE FOR DIABETES CareLink Report Reference Guide 1 Report Reference Guide THERAPY MANAGEMENT SOFTWARE FOR DIABETES CareLink Report Reference Guide 1 How to use this guide Each type of CareLink report and its components are described in the following sections.

More information

Advances in Diabetes Care Technologies

Advances in Diabetes Care Technologies Advances in Diabetes Care Technologies 1979 2015 Introduction Roughly 20% to 30% of patients with T1DM and fewer than 1% of insulin-treated patients with T2DM use an insulin pump In 2007, the U.S. FDA

More information

REPORT INTERPRETATION

REPORT INTERPRETATION REPORT INTERPRETATION: Interpreting ipro Professional Continuous Glucose Monitoring (CGM) Reports and Making Therapy Adjustments TARGET AUDIENCE The audience for this section is physicians, mid-level practitioners,

More information

Continuous Glucose Monitoring Considerations for the Development of a Closed-Loop Artificial Pancreas System

Continuous Glucose Monitoring Considerations for the Development of a Closed-Loop Artificial Pancreas System Journal of Diabetes Science and Technology Volume 5, Issue 6, November 2011 Diabetes Technology Society SYMPOSIUM Continuous Glucose Monitoring Considerations for the Development of a Closed-Loop Artificial

More information

Diabetes Technology Update. Sarah Konigsberg, MD Diabetes & Endocrine Assoc. April 7, 2018

Diabetes Technology Update. Sarah Konigsberg, MD Diabetes & Endocrine Assoc. April 7, 2018 Diabetes Technology Update Sarah Konigsberg, MD Diabetes & Endocrine Assoc. April 7, 2018 Disclosures None No future technologies are FDA approved Continuous Glucose Monitors Continuous Glucose Monitors

More information

Norbert Hermanns, PhD 1,2, Beatrix Schumann, MD 2, Bernhard Kulzer, PhD 1,2, and Thomas Haak, MD 1,2. Original Article

Norbert Hermanns, PhD 1,2, Beatrix Schumann, MD 2, Bernhard Kulzer, PhD 1,2, and Thomas Haak, MD 1,2. Original Article 524105DSTXXX10.1177/1932296814524105Journal of Diabetes Science and TechnologyHermanns et al research-article2014 Original Article The Impact of Continuous Glucose Monitoring on Low Interstitial Glucose

More information

Insulin Delivery and Glucose Monitoring Methods for Diabetes Mellitus: Comparative Effectiveness

Insulin Delivery and Glucose Monitoring Methods for Diabetes Mellitus: Comparative Effectiveness Insulin Delivery and Glucose Monitoring Methods for Diabetes Mellitus: Comparative Effectiveness Prepared for: Agency for Healthcare Research and Quality (AHRQ) www.ahrq.gov Outline of Material Introduction

More information

Factors Influencing the Effectiveness of Glucagon for Preventing Hypoglycemia

Factors Influencing the Effectiveness of Glucagon for Preventing Hypoglycemia Journal of Diabetes Science and Technology Volume 4, Issue 6, November 2010 Diabetes Technology Society SYMPOSIUM Factors Influencing the Effectiveness of Glucagon for Preventing Hypoglycemia Jessica R.,

More information

The Diamond Study: Continuous Glucose Monitoring In Patients on Mulitple Daily Insulin Injections

The Diamond Study: Continuous Glucose Monitoring In Patients on Mulitple Daily Insulin Injections 8/5/217 The Diamond Study: Continuous Glucose Monitoring In Patients on Mulitple Daily Insulin Injections Richard M. Bergenstal, MD Executive Director International Diabetes Center at Park Nicollet Minneapolis,

More information

Pumps & Sensors made easy. OPADA ALZOHAILI MD FACE Endocrinology Assistant Professor Wayne State University

Pumps & Sensors made easy. OPADA ALZOHAILI MD FACE Endocrinology Assistant Professor Wayne State University Pumps & Sensors made easy OPADA ALZOHAILI MD FACE Endocrinology Assistant Professor Wayne State University DeFronzo RA. Diabetes. 2009;58:773-795. Ominous Octet Relationship of b-cell Dysfunction and Development

More information

Continuous or Intermittent Glucose Monitoring in Interstitial Fluid

Continuous or Intermittent Glucose Monitoring in Interstitial Fluid Continuous or Intermittent Glucose Monitoring in Interstitial Fluid Policy Number: 1.01.20 Last Review: 9/2018 Origination: 11/2001 Next Review: 9/2019 Policy Blue Cross and Blue Shield of Kansas City

More information

Effective Health Care Program

Effective Health Care Program Comparative Effectiveness Review Number 57 Effective Health Care Program Methods for Insulin Delivery and Glucose Monitoring: Comparative Effectiveness Executive Summary Background Diabetes mellitus is

More information

Sensor Life and Overnight Closed Loop: A Randomized Clinical Trial

Sensor Life and Overnight Closed Loop: A Randomized Clinical Trial 678631DSTXXX10.1177/1932296816678631Journal of Diabetes Science and TechnologyTauschmann et al research-article2016 Original Article Sensor Life and Overnight Closed Loop: A Randomized Clinical Trial Journal

More information

Subject Index. Breastfeeding, self-monitoring of blood glucose 56

Subject Index. Breastfeeding, self-monitoring of blood glucose 56 Subject Index Animas Vibe 86, 130 Artificial pancreas clinical studies inpatient studies 175 180 outpatient studies outcome assessment 182, 183 technology 180, 181 telemedicine 182 components glucose sensor

More information

The Dual Hormonal Artificial Pancreas in Diabetes Management. Medical Innovation Day Challenge

The Dual Hormonal Artificial Pancreas in Diabetes Management. Medical Innovation Day Challenge The Dual Hormonal Artificial Pancreas in Diabetes Management Medical Innovation Day Challenge 1 Background for the challenge A paradigm shift in treating diabetes Zealand Pharma is a Danish biotech company

More information

Future Direction of Artificial Pancreas. Roy W. Beck, MD, PhD. JAEB Center for Health Research Tampa, Florida

Future Direction of Artificial Pancreas. Roy W. Beck, MD, PhD. JAEB Center for Health Research Tampa, Florida Future Direction of Artificial Pancreas Roy W. Beck, MD, PhD JAEB Center for Health Research Tampa, Florida Financial Disclosures Dr. Beck does not have any personal conflicts of interest His employer,

More information

Diabetes Technology Continuous Subcutaneous Insulin Infusion Therapy And Continuous Glucose Monitoring In Adults: An Endocrine Society Clinical

Diabetes Technology Continuous Subcutaneous Insulin Infusion Therapy And Continuous Glucose Monitoring In Adults: An Endocrine Society Clinical Diabetes Technology Continuous Subcutaneous Insulin Infusion Therapy And Continuous Glucose Monitoring In Adults: An Endocrine Society Clinical Practice Guideline Task Force Members Anne Peters, MD (Chair)

More information

Advances in Diabetes Care Technologies

Advances in Diabetes Care Technologies 1979 Advances in Diabetes Care Technologies 2015 Introduction Roughly 20% - 30% of patients with T1DM and fewer than 1% of insulin-treated patients with T2DM use an insulin pump In 2007, the US FDA estimated

More information

1. Continuous Glucose Monitoring

1. Continuous Glucose Monitoring 1. Continuous Glucose Monitoring 1. Physiology of interstitial fluid glucose 2. Comparison of CGM and self-monitored blood glucose (SMBG) data 3. Insulin dosing indication in BGM vs. CGM & the FDA 4. Protection

More information

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

Medical Policy An independent licensee of the Blue Cross Blue Shield Association Continuous or Intermittent Monitoring of Glucose in Interstitial Fluid Page 1 of 26 Medical Policy An independent licensee of the Blue Cross Blue Shield Association Title: Continuous or Intermittent Monitoring

More information

Supplementary Appendix

Supplementary Appendix Supplementary Appendix This appendix has been provided by the authors to give readers additional information about their work. Supplement to: Bergenstal RM, Klonoff DC, Garg SK, et al. -based insulin-pump

More information

The In-Clinic Close Loop Experience in the US

The In-Clinic Close Loop Experience in the US The In-Clinic Close Loop Experience in the US Keystone Symposium, Practical Ways to Achieve Targets in Diabetes Care July 14, 2012 Francine Ratner Kaufman, MD Chief Medical Officer, VP Global Medical,

More information

Insulin Pump Therapy in children. Prof. Abdulmoein Al-Agha, FRCPCH(UK)

Insulin Pump Therapy in children. Prof. Abdulmoein Al-Agha, FRCPCH(UK) Insulin Pump Therapy in children Prof. Abdulmoein Al-Agha, FRCPCH(UK) aagha@kau.edu.sa Highlights Evolution of insulin pump Pumps mimics Pancreas Goals of diabetes care What lowers HbA1c Criteria for selection

More information

The Hypoglycaemia-Hyperglycaemia Minimizer System in the Management of Type 1 Diabetes. Brian L Levy, Thomas W McCann, Jr and Daniel A Finan

The Hypoglycaemia-Hyperglycaemia Minimizer System in the Management of Type 1 Diabetes. Brian L Levy, Thomas W McCann, Jr and Daniel A Finan Diabetes The Hypoglycaemia-Hyperglycaemia Minimizer System in the Management of Type 1 Diabetes Brian L Levy, Thomas W McCann, Jr and Daniel A Finan Animas Corporation, Wayne, USA DOI: http://doi.org/10.17925/ee.2016.12.01.18

More information

A Composite Model of Glucagon Glucose Dynamics for In Silico Testing of Bihormonal Glucose Controllers

A Composite Model of Glucagon Glucose Dynamics for In Silico Testing of Bihormonal Glucose Controllers Journal of Diabetes Science and Technology Volume 7, Issue 4, July 2013 Diabetes Technology Society ORIGINAL ARTICLE A Composite Model of Glucagon Glucose Dynamics for In Silico Testing of Bihormonal Glucose

More information

Original Article. Nicholas B. Argento, MD 1 ; Katherine Nakamura, PhD 2 ABSTRACT

Original Article. Nicholas B. Argento, MD 1 ; Katherine Nakamura, PhD 2 ABSTRACT Original Article Nicholas B. Argento, MD 1 ; Katherine Nakamura, PhD 2 ABSTRACT Objective: Little information is available on personal real-time continuous glucose monitoring (PCGM) in patients 65 years

More information

Hybrid Closed Loop Status & Practical Challenges in Implementation

Hybrid Closed Loop Status & Practical Challenges in Implementation Hybrid Closed Loop Status & Practical Challenges in Implementation Bruce Buckingham, MD Buckingham@Stanford.edu Professor of Pediatric Endocrinology Stanford School of Medicine Conflict of Interests Company

More information

A Bihormonal Closed-Loop Artificial Pancreas for Type 1 Diabetes

A Bihormonal Closed-Loop Artificial Pancreas for Type 1 Diabetes DIABETES A Bihormonal Closed-Loop Artificial Pancreas for Type 1 Diabetes Firas H. El-Khatib, 1 * Steven J. Russell, 2 * David M. Nathan, 2 Robert G. Sutherlin, 2 Edward R. Damiano 1 (Published 14 April

More information

T he benefits of intensive treatment of

T he benefits of intensive treatment of Clinical Care/Education/Nutrition/Psychosocial Research O R I G I N A L A R T I C L E Effect of Continuous Glucose Monitoring on Hypoglycemia in Type 1 Diabetes TADEJ BATTELINO, MD, PHD 1 MOSHE PHILLIP,

More information

Medical Policy. MP Continuous or Intermittent Monitoring of Glucose in Interstitial Fluid. Related Policies None

Medical Policy. MP Continuous or Intermittent Monitoring of Glucose in Interstitial Fluid. Related Policies None Medical Policy BCBSA Ref. Policy: 1.01.20 Last Review: 11/15/2018 Effective Date: 11/15/2018 Section: Durable Medical Equipment Related Policies None DISCLAIMER Our medical policies are designed for informational

More information

UNCOVERING THE BENEFITS OF THE ACCU- CHEK BOLUS ADVISOR MICHAEL PORTER CDE

UNCOVERING THE BENEFITS OF THE ACCU- CHEK BOLUS ADVISOR MICHAEL PORTER CDE UNCOVERING THE BENEFITS OF THE ACCU- CHEK BOLUS ADVISOR MICHAEL PORTER CDE 1 LEARNING OBJECTIVES By the end of this session participants should be able to understand: The benefits of bolus advisors The

More information

In press: Diabetes and its Complications Sept 2014 FACTORS AFFECTING THE SUCCESS OF GLUCAGON DELIVERED DURING AN

In press: Diabetes and its Complications Sept 2014 FACTORS AFFECTING THE SUCCESS OF GLUCAGON DELIVERED DURING AN In press: Diabetes and its Complications Sept 2014 FACTORS AFFECTING THE SUCCESS OF GLUCAGON DELIVERED DURING AN AUTOMATED CLOSED-LOOP SYSTEM IN TYPE 1 DIABETES Bakhtiani P.A 1., El Youssef J 1., Duell

More information

Objectives. The Problem. We ve come a LONG way, Innovations in Diabetes Care and Management. Barbara Walz, RN, BSN, CDE April 26, 2018

Objectives. The Problem. We ve come a LONG way, Innovations in Diabetes Care and Management. Barbara Walz, RN, BSN, CDE April 26, 2018 Objectives Innovations in Diabetes Care and Management Barbara Walz, RN, BSN, CDE April 26, 2018 1. Briefly discuss the history of diabetes management over the past 100 years 2. Describe the impact of

More information

Abstract CLINICAL APPLICATIONS. Objectives: Methods: Results: Conclusion: Journal of Diabetes Science and Technology

Abstract CLINICAL APPLICATIONS. Objectives: Methods: Results: Conclusion: Journal of Diabetes Science and Technology Journal of Diabetes Science and Technology Volume 1, Issue 3, May 2007 Diabetes Technology Society CLINICAL APPLICATIONS Combined Insulin Pump Therapy with Real-Time Continuous Glucose Monitoring Significantly

More information

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

Medical Policy An independent licensee of the Blue Cross Blue Shield Association Continuous or Intermittent Monitoring of Glucose in Interstitial Fluid Page 1 of 39 Medical Policy An independent licensee of the Blue Cross Blue Shield Association Title: Continuous or Intermittent Monitoring

More information

How I use the latest technology to investigate and treat a person with Type 1 Diabetes. Dr Pratik Choudhary

How I use the latest technology to investigate and treat a person with Type 1 Diabetes. Dr Pratik Choudhary How I use the latest technology to investigate and treat a person with Type 1 Diabetes Dr Pratik Choudhary Disclosures Advisory board and speaker fees from Medtronic, Roche, Abbott and Johnson and Johnson,

More information

Sensor-augmented pump systems provide insulin delivery

Sensor-augmented pump systems provide insulin delivery DIABETES TECHNOLOGY & THERAPEUTICS Volume 18, Number 10, 2016 Mary Ann Liebert, Inc. DOI: 10.1089/dia.2016.0216 ORIGINAL ARTICLE Effectiveness of Automated Insulin Management Features of the MiniMed c

More information

CGM Use in Pregnancy & Unique Populations ELIZABETH O. BUSCHUR, MD THE OHIO STATE UNIVERSITY WEXNER MEDICAL CENTER

CGM Use in Pregnancy & Unique Populations ELIZABETH O. BUSCHUR, MD THE OHIO STATE UNIVERSITY WEXNER MEDICAL CENTER CGM Use in Pregnancy & Unique Populations ELIZABETH O. BUSCHUR, MD THE OHIO STATE UNIVERSITY WEXNER MEDICAL CENTER Case 1: CGM use during pregnancy 29 yo G1P0000 at 10 5/7 weeks gestation presents to set

More information

Target Audience. approach this patient case scenario, including identifying an

Target Audience. approach this patient case scenario, including identifying an Activity Overview In this case-based webcast, meet LaWanda, a 57-year-old woman with type 2 diabetes. Her glycated hemoglobin (HbA1C) is 8.4%, she is currently taking basal insulin and fast-acting insulin,

More information

Artificial Pancreas Goes Outpatient: A New Diabetes Ecosystem

Artificial Pancreas Goes Outpatient: A New Diabetes Ecosystem Journal of Diabetes Science and Technology Volume 7, Issue 6, November 2013 Diabetes Technology Society EDITORIAL Artificial Pancreas Goes Outpatient: A New Diabetes Ecosystem Eric, M.D., Ph.D., 1,2,3

More information

Insulin Initiation and Intensification. Disclosure. Objectives

Insulin Initiation and Intensification. Disclosure. Objectives Insulin Initiation and Intensification Neil Skolnik, M.D. Associate Director Family Medicine Residency Program Abington Memorial Hospital Professor of Family and Community Medicine Temple University School

More information

NOTE: The first appearance of terms in bold in the body of this document (except titles) are defined terms please refer to the Definitions section.

NOTE: The first appearance of terms in bold in the body of this document (except titles) are defined terms please refer to the Definitions section. TITLE GLYCEMIC MANAGEMENT - ADULT SCOPE Provincial: Acute Care APPROVAL AUTHORITY Clinical Operations Executive Committee SPONSOR Diabetes, Obesity & Nutrition Strategic Clinical Network PARENT DOCUMENT

More information

Agreement between Glucose Trends Derived from Three Simultaneously Worn Continuous Glucose Sensors

Agreement between Glucose Trends Derived from Three Simultaneously Worn Continuous Glucose Sensors Journal of Diabetes Science and Technology Volume 2, Issue 5, September 2008 Diabetes Technology Society ORIGINAL ARTICLES Agreement between Glucose Trends Derived from Three Simultaneously Worn Continuous

More information

Commissioning Policy Individual Funding Request

Commissioning Policy Individual Funding Request Commissioning Policy Individual Funding Request Continuous Glucose Monitors Prior Approval Policy Date Adopted: 13 October 2017 Version: 1718.2 Document Control Title of document Continuous Glucose Monitors

More information

Hypoglycemia Detection and Prediction Using Continuous Glucose Monitoring A Study on Hypoglycemic Clamp Data

Hypoglycemia Detection and Prediction Using Continuous Glucose Monitoring A Study on Hypoglycemic Clamp Data Journal of Diabetes Science and Technology Volume 1, Issue 5, September 2007 Diabetes Technology Society SYMPOSIUM Hypoglycemia Detection and Prediction Using Continuous Glucose Monitoring A Study on Hypoglycemic

More information

Emerging Automated Insulin Delivery Systems

Emerging Automated Insulin Delivery Systems Emerging Automated Insulin Delivery Systems Richard M. Bergenstal, MD International Diabetes Center Park Nicollet & HealthPartners Minneapolis, MN Presenter Name 1 Dualities: Richard M. Bergenstal, MD

More information

Autonomous and Continuous Adaptation of a Bihormonal Bionic Pancreas in Adults and Adolescents With Type 1 Diabetes

Autonomous and Continuous Adaptation of a Bihormonal Bionic Pancreas in Adults and Adolescents With Type 1 Diabetes ORIGINAL Endocrine ARTICLE Research Autonomous and Continuous Adaptation of a Bihormonal Bionic Pancreas in Adults and Adolescents With Type 1 Diabetes Firas H. El-Khatib,* Steven J. Russell,* Kendra L.

More information