HeartStart MRx Instructions for Use Addendum

Size: px
Start display at page:

Download "HeartStart MRx Instructions for Use Addendum"

Transcription

1 HeartStart MRx Instructions for Use Addendum For software Version 9.xx M3535A/M3536A HeartStart MRx

2

3 Notice About This Edition Printed in the USA Publication number: The information in this document applies to the M3535A and M3536A HeartStart MRx. This information is subject to change without notice. Philips shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Edition Print Date 1 July, 2007 Copyright Copyright 2007 Koninklijke Philips Electronics N.V. All rights are reserved. Permission is granted to copy and distribute this document for your organization s internal educational use. Reproduction and/or distribution outside your organization in whole or in part is prohibited without the prior written consent of the copyright holder. Rosetta-Lt, Rosetta-Rx and CAREpoint are trademarks of General Devices. Bluetooth wireless technology is a registered trademark of Bluetooth SIG, Inc. Steris Coverage Plus NPD is a registered trademark of Steris Corp. Q-CPR is a trademark of Laerdal Medical. CidexPlus is a registered trademark of Advanced Sterilization Products. Nellcor is a registered trademark of Nellcor Puritan Bennett, Inc. TransPac IV is a registered trademark of ICU Medical, Inc. TruWave is a registered trademark of Edwards Lifescience Corp. DTX Plus is a trademark of Becton, Dickinson & Co. Other trademarks and trade names are those of their respective owners. Use of supplies or accessories other than those recommended by Philips may compromise product performance. THIS PRODUCT IS NOT INTENDED FOR HOME USE. IN THE U.S., FEDERAL LAW RESTRICTS THIS DEVICE TO SALE ON OR BY THE ORDER OF A PHYSICIAN. Medical Device Directive The HeartStart MRx complies with the requirements of the Medical Device Directive 93/42/EEC and carries the 0123 mark accordingly. Manufacturer Philips Medical Systems 3000 Minuteman Road Andover, MA USA Authorized EU-representative Philips Medizin Systeme Böblingen GmbH Hewlett Packard Str Böblingen Germany For the Declaration of Conformity Statement, please see the Philips Medical web site at incenter.medical.philips.com/pmspublic. Scroll over the Quality and Regulatory Tab located in the upper left corner of the window. Click to select Regulatory by Modality. Then click to select Defibrillators and select the entry for Declaration of Conformity (DoC). Canada EMC:ICES-001 U.S. FCC and Industry Canada Radio Compliance: Contains FCC ID: PQC-WMTS-MODULE Operation of this equipment requires the prior coordination with a frequency coordinator designated by the FCC for the Wireless Medical Telemetry Service. This device complies with Part 15 of the FCC rules and RSS-210 of Industry Canada. Operation is subject to the following conditions: This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications to this equipment not expressly approved by Philips Medical Systems may cause harmful radio frequency interference and void your authority to operate this equipment. Warning Radio frequency (RF) interference coming from devices other than the HeartStart MRx may degrade the performance of the MRx. Electromagnetic compatibility with surrounding devices should be assessed prior to using the monitor/defibrillator. iii

4 This addendum to the Instructions for Use contain the following conventions: WARNING Warning statements describe conditions or actions that can result in personal injury or loss of life. CAUTION Caution statements describe conditions or actions that can result in damage to the equipment or loss of data. Notes contain additional information on usage. TEXT represents messages that appear on the display [Softkey] represents softkey labels that appear on the display above or below the button to which they correspond. Function keys: Menu Select button - Pressing the Menu Select button brings up the current menu or confirms a menu selection. Navigation buttons - The Navigation buttons display the current menu just as the Menu Select button does. Additionally, within any menu or list, these buttons move to the next or previous item on the list. They also increase or decrease numbers or values in a sequence. Images of the HeartStart MRx display and menus appearing in this document are for illustration purposes only. Menu choices on your device are driven by the options you have and selections you make in Configuration Mode. iv

5 1Table of Contents Introduction Lead Acute MI Warning Statements... 2 Configuring Acute MI Statements... 2 Generating the Acute MI message... 3 Transmitting Data... 4 Preparing for Transmission Lead Transmission, Rosetta-Lt... 7 Connecting the Devices... 8 Transmitting Data in Data Management Mode... 9 Transmitting Data in 12-Lead Mode Tracking Data Transmission Transmission Errors Cancelling a Transmission Queuing Transmissions Finding Transmission Results Copy and Print Printing Copying Latching Alarms Pacer Output Yellow Alarm External Paddles Cleaning Event Summary Modification Environmental Specifications Bluetooth Specifications Configuration Modifications Parameter Block Numerics Supplies and Accessories v

6

7 Introduction Thank you for choosing the HeartStart MRx monitor/defibrillator. Software Version 9.xx extends the HeartStart MRx s monitoring, resuscitation and data management functionality. This document is an addendum to the HeartStart MRx Instructions for Use. It explains how to use the new features of the HeartStart MRx running software Version 9.xx including: 12-Lead Simplified Acute MI Statements. If configured On, a simple ACUTE MI warning statement appears on the 12-Lead Report screen to quickly catch your attention that the 12-Lead Algorithm has detected an acute MI. See 12-Lead Acute MI Warning Statements on page 2. The Rosetta-Lt transmission device. Two-way radio is added to the suite of HeartStart MRx transmission options (available in the United States only). You can transmit 12-Lead Reports to a healthcare facility using the Rosetta-Lt. See 12-Lead Transmission, Rosetta-Lt on page 7. Event Summary, Bluetooth wireless data transmission. You can transmit an Event Summary via Bluetooth to an external computer. See Transmitting Data in Data Management Mode on page 9. Q-CPR configuration. You can configure Q-CPR to be On or Off at startup. See Configuration Modifications on page 18. Parameter Block Numbers. Noninvasive blood pressure numerics in Parameter Block 1 are larger when temperature numerics are not displayed. Invasive pressure numerics in Parameter Block 2 are larger when EtCO 2 numerics are not displayed. See Parameter Block Numerics on page 19. Copy and Print individual 12-Lead Reports from Data Management Mode. You can copy and print individual 12-Lead Reports from Data Management Mode. See Copy and Print on page 14. Latching Alarms Modification. A modification to latching alarms, introduced with Version 8.xx software. For more information, see Latching Alarms on page 16. With this addendum, the HeartStart MRx Instructions for Use, labeled for use with software version 7, can also be used with devices running version 8.xx or 9.xx software. Keep this addendum with your HeartStart MRx Instructions for Use. 1

8 12-Lead Acute MI Warning Statements 12-Lead Acute MI Warning Statements To aid in quickly identifying an acute myocardial infarction, the HeartStart MRx displays a simple ACUTE MI warning statement on the 12-Lead Report screen when the Philips 12-Lead Algorithm detects an acute MI. See Figure 1. The 12-Lead Algorithm uses measurements and patient information (age, gender, paced status) to generate interpretive statements describing the patient s cardiac rhythm and waveform morphology. Figure 1 Acute MI Indication Aug :19:00 55 years Male HR 60 SINUS RHYTHM PR 168 CONSIDER RIGHT ATRIAL ABNORMALITY QRSD 74 INFERIOR INJURY, PROBABLE EARY ACUTE INFARCT QT 360 ANT-SEPT INJURY, PROBABLE EARLY ACUTE INFARCT QTc 360 LATERAL LEADS ARE ALSO INVOLVED --Axis-- P 52 QRS 45 T 41 -ABNORMAL ECG- Unconfirmed diagnosis >>>> ACUTE MI <<<< Start NBP Exit 12-Lead New 12-Lead Print MENU The simplified ACUTE MI warning statement also appears on the 12-Lead Report printed by the HeartStart MRx. It does not appear on 12-Lead Reports transmitted to a healthcare facility. For more information about 12-Lead ECG and the 12-Lead Report see the 12-Lead ECG chapter in the HeartStart MRx Instructions for Use. For a list of interpretive statements and their acceptance criteria, see Acute MI Warning Statements on page 3. Configuring Acute MI Statements You can enable/disable acute MI statement display and printing in Configuration Mode s 12-Lead Configuration Screen. See Table 1 for the added configuration option. For a complete list of HeartStart MRx configurable parameters and how to access Configuration Mode, see the Configuration chapter of the HeartStart MRx Instructions for Use. Table 1 Acute MI Statement Configuration Parameter Description Setting Choices (Default in bold) Acute MI Indication Defines whether the ACUTE MI simplified statement appears on the 12-Lead display and is printed on the 12-Lead Report. Yes, No 2

9 12-Lead Acute MI Warning Statements Generating the Acute MI message Table 2 lists the 24 interpretive statements that generate an ACUTE MI message. Table 2 Acute MI Warning Statements Description Criteria PROBABLE ANTEROLATERAL INFARCT, ACUTE ST >0.15 mv, Q >30 ms, V2-V5 ANTEROLATERAL INFARCT, ACUTE Q >35 ms, ST >0.20 mv, V2-V6 ANTEROLATERAL INJURY, EARLY ACUTE INFARCT ST >0.15 mv, I avl V2-V6 PROBABLE ANTEROSEPTAL INFARCT, ACUTE Q >30 ms, ST>0.15 mv, V1-V3 ANT-SEPT INJURY, PROBABLE EARLY ACUTE INFARCT ST >0.40 mv V1-V3 ANTERIOR INFARCT, ACUTE Q >30 ms, ST >0.25 mv, V1-V4 ANTERIOR INFARCT, ACUTE ST >0.25 mv, T neg, V1-V5 ANTERIOR INJURY, EARLY ACUTE INFARCT ST >0.35 mv in V1-V5 ANTEROSEPTAL INFARCT, ACUTE Q >30 ms, ST >0.25 mv, V1-V3 EXTENSIVE ANTERIOR INFARCT, ACUTE Q >35 ms, ST >0.15 mv, V1-V6 PROBABLE INFERIOR INFARCT, ACUTE Q>25 ms, ST>0.10 mv, II III avf INFERIOR INFARCT, POSSIBLY ACUTE Q >35 ms, ST >0.10 mv, II III avf INFERIOR INFARCT, ACUTE Q>35 ms, ST>0.07 mv, T neg, II-aVF INFERIOR INJURY, PROBABLE EARLY ACUTE INFARCT ST>0.15 mv, II III avf INFEROPOSTERIOR INFARCT, ACUTE ST >.10 II III avf, <-.05 V1-V4 PROBABLE LATERAL INFARCT, ACUTE Q >25 ms, ST>0.10 mv, I avl V5 V6 LATERAL INFARCT, ACUTE ST >.20 mv, Q >35 ms, I avl V5 V6 LATERAL INJURY, PROBABLE EARLY ACUTE INFARCT ST >0.10 mv, I avl V5 V6 ST ELEVATION, PROBABLE ANTERIOR INJURY ST >0.25 mv in V1-V5 ST ELEVATION, PROBABLE ANTEROLATERAL INJURY ST >0.15 mv, I avl V2-V6 ST ELEVATION, PROBABLE INFERIOR INJURY inf ST>0.1 mv, lat ST<-0.05 mv ST ELEVATION, PROBABLE LATERAL INJURY ST >0.08 mv, I avl V5 V6 POSTERIOR INFARCT, ACUTE prominent R T, ST <-.05 V1-V4 PROBABLE POSTERIOR INFARCT, ACUTE prominent R T, ST <-.05 V1-V3 3

10 Transmitting Data Transmitting Data Software version 9.xx extends the HeartStart MRx s suite of data transmission options. See Transmission Use Cases on page 6 for examples. You can configure up to 20 Bluetooth transmission devices. In addition to the transmission options listed in the HeartStart MRx Instructions for Use, you can: Transmit a 12-Lead Report via the Rosetta-Lt - The HeartStart MRx uses the Rosetta-Lt with a cable plugged into the RS-232 port to transmit a 12-Lead Report from the 12-Lead screen (during clinical use) or Data Management Mode (after clinical use) to the Rosetta-Lt for your eventual transmission to a healthcare facility. See Figure 2 and 12-Lead Transmission, Rosetta-Lt on page 7. Figure 2 Transmission via the Rosetta-Lt University Hospital Children's Hospital PLACE MIC ON PAD POWER START STOP Tx/Rx Rosetta - Lt Data Translator GENERA DEVICES HeartStart MRx Rosetta-Lt 2-Way Radio Radio Tower Receiving device at a healthcare facility Transmit an Event Summary to an external computer - The HeartStart MRx uses Bluetooth wireless technology to transmit an Event Summary from Data Management Mode to a nearby personal computer/laptop/tablet/mobile device after clinical use. See Figure 3 and Transmitting Data in Data Management Mode on page 9. Transmit a 12-Lead Report to an external computer - The HeartStart MRx uses Bluetooth wireless technology to transmit a 12-Lead Report from the 12-Lead screen (during clinical use) or Data Management Mode (after clinical use) to a nearby Bluetooth-enabled personal computer/laptop/ tablet/mobile device. See Figure 3, Transmitting Data in Data Management Mode on page 9 and Transmitting Data in 12-Lead Mode on page 10. Figure 3 Transmitting to an External Computer HeartStart MRx Personal Computer/ Laptop/ Tablet/ Mobile Device 4

11 Transmitting Data Preparing for Transmission Before transmitting data, the HeartStart MRx needs to be set up properly and, if you are using Bluetooth wireless technology, the wireless devices need to be set up. See the 12-Lead ECG Transmission chapter in the HeartStart Instructions for Use for more information on configuring sites and adding Bluetooth devices. CAUTION The process for adding a Bluetooth device for a telephone transmission (documented in the Instructions for Use) differs slightly than adding a Bluetooth device for the Event Summary, Bluetooth option. You will not be prompted to select a profile when adding a Bluetooth device as part of the Event Summary, Bluetooth option. After completing the transmission test, return to this document for instructions on how to transmit data. The HeartStart MRx is capable of communicating via Bluetooth with nearby devices such as computers, laptops, tablets and mobile devices. Each of these devices has a unique set of features and configuration options. In order to ensure reliable transmissions, familiarize yourself with the Bluetooth configuration choices of each. Some choices (either default or chosen by the user) could prevent receipt of data from the HeartStart MRx. For example, it is recommended that you disable features such as Start discovery every 10 minutes. Enabling this option could interfere with transmissions from the HeartStart MRx. The process for setting up a Bluetooth wireless transmission device in Version 9.xx software may have one additional step. After the pairing process is complete, you are prompted to select a Bluetooth Service. Highlight File Transfer or Dial-Up Networking and press the Menu Select button. If you are unsure of which service to select, contact your Philips installation manager for more information. 5

12 Transmitting Data I want to transmit: Table 3 An Event Summary to an external computer wirelessly 1. A 12-Lead ECG using the RS-232 port, a cell phone and the Internet to a destination point. 2 A 12-Lead ECG using Bluetooth wireless technology via a cell phone, land line modem or other cellular broadband gateway to the Internet. A 12-Lead ECG using a 2-way radio and the Rosetta-Lt to a CAREpoint or Rosetta-Rx device at a healthcare facility 3. A 12-Lead ECG using electronic PCR software in my portable computer 4. Transmission Use Cases The HeartStart MRx uses: Bluetooth wireless technology to transmit data to a Bluetoothenabled computer. The RS-232 port to transmit data through a cell phone to a selected destination. Dial Up Networking (DUN) and a Bluetooth wireless card to transmit a 12- Lead ECG through a cell phone, land line modem or other gateway to a destination point. An RS-232 cable 5 to connect the HeartStart MRx to the Rosetta-Lt, which then transmits to a destination point. Bluetooth File Transfer and a Bluetooth wireless card to transmit the 12-Lead ECG to the PC. What transmission options does my HeartStart MRx need to make it work? The Event Summary Bluetooth option (B10) OR product upgrades (Event Summary, Bluetooth) and (Internal Bluetooth Card). The 12-Lead Transmission - RS-232 and Bluetooth option (B07) OR product upgrades M3802 (12-Lead BT/RS-232 Transmit) and (Internal Bluetooth Card). The 12-Lead Transmission - Bluetooth wireless technology option (B06) OR product upgrades M3801 (12-Lead BT Transmit) and (Internal Bluetooth Card). The 12-Lead Transmission, Rosetta-Lt interface option (B11) OR product upgrade (12-Lead transmission, Rosetta- Lt Interface). The Event Summary Bluetooth option (B10) AND one of the 12-Lead Transmission options (Serial, Bluetooth or Rosetta-Lt) installed. Where do I find instructions? See Transmitting Data in Data Management Mode on page 9. See the 12-Lead Transmission chapter in the HeartStart MRx Instructions for Use. See Transmitting Data in Data Management Mode on page 9 and/or Transmitting Data in 12-Lead Mode on page 10. See 12-Lead Transmission, Rosetta-Lt on page 7. See Transmitting Data in Data Management Mode on page 9 and/or Transmitting Data in 12-Lead Mode on page 10. : Combining various options allows you the flexibility of multiple transmission avenues. Functionality remains the same with added options. All options work together, however the Rosetta-Lt option can t be used at the same time as the RS-232 port option or the IntelliVue Networking backpack. All three use the same physical connection to the HeartStart MRx. 1 Windows-based personal computer/laptop/tablet/mobile device with a Bluetooth stack installed that supports File Transfer Profile Server. See Bluetooth Specifications on page 17 for more information. 2 There are a limited number of carriers and cellphones which support this feature. Consult your Philips Sales Representative for more information. 3 Available in the U.S. only. 4 Patient Care Report (PCR) software must be able to deliver the file to the healthcare facility. The destination site set at the HeartStart MRx is contained in the file information transmitted. If you use a Philips product to deliver the file to the healthcare facility, it reads the destination site from the file sent. For more information on the set-up of your epcr software, see the software s Instructions for Use. 5 Cable provided by General Devices. For more information concerning the setup and configuration of transmission devices and the HeartStart MRx, see the latest version of the Philips 12-Lead Transmission Implementation Guide and the HeartStart MRx Instructions for Use. 6

13 Transmitting Data 12-Lead Transmission, Rosetta-Lt With Version 9.xx software, the HeartStart MRx enables you to transmit a 12-Lead Report to a Rosetta-Lt for two-way radio transmission to a healthcare facility running CAREpoint or Rosetta-Rx. WARNING Do not connect the HeartStart MRx to the Rosetta-Lt when the Rosetta-Lt is connected to a telephone line. This combination is prohibited. Before connecting the Rosetta-Lt to a telephone line, disconnect it from the HeartStart MRx. The 12-Lead Report sent to the Rosetta-Lt includes: Patient identification information Device identification information Event ID number Waveform data Optional information in the 12-Lead Report includes: Measurements. The 12-Lead Report can also contain numerics for vital signs (SpO 2, EtCO 2, AwRR, Pulse, Temp, Invasive Pressure, NBP) if available. The vitals sent with the report are the values recorded at the beginning of the 12-Lead acquisition. If a vital numeric is unavailable or its source is off, then the vital numeric is not included in the report. NBP numerics are valid for 60 minutes. If no measurement has been taken in the last 60 minutes, NBP numerics are considered unavailable. NBP numerics include the measurement time. Statements Rhythm strips CAUTION The HeartStart MRx sends the above data to the Rosetta-Lt. Information displayed on the 12-Lead Report produced by the Rosetta-Lt is determined by Rosetta-Lt software. A 12-Lead Report sent to the Rosetta-Lt will overwrite any 12-Lead Report which currently exists on the Rosetta-Lt. It is your responsibility to forward the 12-Lead Report from the Rosetta-Lt to its destination. See the Rosetta-Lt User s Guide for more information. If your HeartStart MRx is transmitting a 12-Lead Report via means other than the Rosetta-Lt, the Rosetta-Lt option is disabled in the Send to menu until the transmission is complete. 7

14 Transmitting Data Connecting the Devices To connect the Rosetta-Lt to the HeartStart MRx, insert the Rosetta-Lt cable into the HeartStart MRx s RS-232 Serial port and tighten the screws. See Figure 4. Figure 4 Attaching the Rosetta-Lt to the HeartStart MRx PLACEMICON PAD START STOP POWER Tx/Rx Rosetta-Lt Data Translator GENERAL DEVICES For questions about the Rosetta-Lt and connector cable or to purchase a connector cable/additional items, contact General Devices. See the Rosetta-Lt Data Translator User s Manual for more information. See Transmitting Data in Data Management Mode on page 9 and Transmitting Data in 12-Lead Mode on page 10 for details on how to send 12-Lead Reports using the HeartStart MRx and the Rosetta-Lt. 8

15 Transmitting Data Transmitting Data in Data Management Mode The HeartStart MRx Event Summary, Bluetooth option uses Bluetooth wireless technology to send an Event Summary (complete or partial) or a 12-Lead Report to a receiving Bluetooth device from Data Management Mode. The Rosetta-Lt transmission device uses two-way radio to transmit 12-Lead Reports from Data Management Mode. Transmitted Event Summaries include all stored waves, trending data, 12-Lead Reports and event files, including vital signs such as heart rate, pulse, SpO 2, EtCO 2, AwRR, NBP, invasive pressure and temperature numerics. If your HeartStart MRx has the Audio and/or Q-CPR Data options, you can include these parts of the Event Summary. Event Summaries can only be transferred to devices that support the Bluetooth File Transfer Profile Server. To transmit an Event Summary or 12-Lead Report from the HeartStart MRx s internal memory to a receiving device, perform the following: 1 After you have finished monitoring the patient and removed them from the HeartStart MRx, place the device into Data Management Mode. The display reads Data Management - Internal Memory across the top. 2 Using the [Prev Item] and [Next Item] softkeys, highlight the Event Summary you want to transmit (or the Event Summary which contains the 12-Lead Report you want to transmit) and press the Menu Select button. 3 Highlight Send and press the Menu Select button. 4 Highlight the type of data you want to transmit (see Figure 5) and press the Menu Select button. Send All Event Data Exclude Audio & Q-CPR 1-25 Apr : Apr :30 Exit Figure 5 Send Functions Highlight All Event Data to send an entire event, including 12-Lead Reports. Text in this menu line varies depending upon the HeartStart MRx options installed: Exclude Audio & Q-CPR is displayed if your device has the Audio Recording, Q- CPR Data and Event Summary, Bluetooth options. Exclude Audio is displayed if your device has the Audio Recording and Event Summary, Bluetooth options and does not have the Q-CPR Data option. Exclude Q-CPR is displayed if your device has the Q-CPR Data and Event Summary, Bluetooth options and does not have the Audio Recording option. Highlight the specific data to exclude it from the Event Summary transmission. If you only want to transmit a specific 12-Lead Report, highlight it to transmit. Highlight Exit to exit the Send menu without transmitting any data. 5 Depending upon which option you selected in Step 4, you are presented with different menus. If you selected a 12-Lead Report: 1 Select a destination for the 12-Lead Report from the Send To menu. Highlight the destination and press the Menu Select button. If your device is configured with just one transmission device or you selected the Rosetta-Lt, transmission begins. 2 If your device has more than one configured transmission device, highlight the transmission device you want to use and press the Menu Select button. Transmission begins. See Figure 6. If you are using the Rosetta-Lt option to transmit 12-Lead Reports, see 12-Lead Transmission, Rosetta-Lt on page 7 for more information. 9

16 Transmitting Data Figure 6 Send All Events Data Exclude Audio & Q-CPR 1-25 Apr : Apr :30 Exit Steps to Sending 12-Leads Send To Rosetta St. Mary's ED St. Joseph s Cath Lab Dr. Smith Dr. Jones EMS Station Fax Number Exit Transmission Devices 1st Configured Device 2nd Configured Device nth Configured Device 20th Configured Device If you selected an Event Summary: If your device is configured with just one transmission device, transmission begins. If your device has more than one configured transmission device, highlight the option you want to use and press the Menu Select button. Transmission begins. See Figure 7. Figure 7 Event Summary Transmission Transmission Devices 1st Configured Device 2nd Configured Device 3rd Configured Device 4th Configured Device If you press the Exit Data Management softkey while a transmission is ongoing, you need to confirm your selection. Selecting Yes exits Data Management, cancels your current transmission and any queued transmissions. Selecting No continues the current transmission. If you print an event in Clinical Mode and switch to Data Management Mode, the printing must be complete before the event can be copied or sent. Failure to do so results in either a Cannot copy this event while printing or a Cannot send this event while printing message. If you get either message, wait for the printing to finish or cancel the printing before proceeding. Transmitting Data in 12-Lead Mode You can transmit a 12-Lead Report while monitoring a patient in 12-Lead Mode. To send the current 12-Lead Report: 1 From the 12-Lead Report screen, press the Menu Select button. 2 Select Send and press the Menu Select button. 3 Select the destination of the 12-Lead from the Send To menu and press the Menu Select button. 4 If your device is configured with just one option to transmit the 12-Lead Report or you selected the Rosetta-Lt, transmission begins when you press the Menu Select button. If your device has more than one configured transmission device, highlight the device you want to use and press the Menu Select button. Transmission begins. See Figure 6. S The HeartStart MRx transmits data from internal memory only. Data contained on the external data card only is not transmittable. If you are using the Rosetta-Lt option to transmit 12-Lead Reports, see 12-Lead Transmission, Rosetta-Lt on page 7 for more information. 10

17 Transmitting Data Tracking Data Transmission After initiating a data transmission from the HeartStart MRx, you can track transmission progress on the device display. For events, the event ID along with the date and time of the event data being sent are displayed while for 12-Lead Reports, the date and time of the report are displayed. The phase progress (Connecting to Device and Sending) is also shown. If the HeartStart MRx is in the process of sending data, a percentage complete is also displayed. See Figure 8. Figure 8 Transmission Progress Screen 25 Jan :52 Sending, 40 % complete Once transmission is complete, a brief Confirming. Stand by... message appears on the display followed by a Disconnecting message. Then the transmission progress message is removed. If a 12-Lead transmission occurs during a patient incident, an event indicating the time of transmission is logged into the current Event Summary. If you exit the Data Management screen or leave a clinical mode causing a reboot of the device during transmission, the transmission is aborted. Changing between clinical views (AED, Monitoring, Pacing, Manual Defibrillation) does not terminate a transmission. Transmission Errors If there is an error in transmission, a message is displayed on the HeartStart MRx screen, accompanied by an audio beep. Press the Menu Select button to acknowledge the error. See Figure 9. The error is logged into the Device Status Log. See Table 4 for new possible transmission errors. See the HeartStart MRx Instructions for Use Troubleshooting chapter for a full list of transmission errors. Figure 9 Transmission Failure Mark Event 10 Feb :20 Jones, Samuel Adult Non-Paced 02:42 HR Temp C Pulse bpm NBP mmhg q120 bpm SYS : II Transmission Failed Connection Failed 120/80 (95) Pleth SpO2 % 100 EtCO2 mmhg AwRR rpm PACING ON BATTERIES Demand Mode 70 ppm 50 ma Start NBP Resume Pacing Pacer Rate Pacer Output Acknowledge 11

18 Transmitting Data Table 4 Transmission Errors Message on HeartStart MRx screen Reason Possible solution No transmission device detected The HeartStart MRx failed If using the Rosetta-Lt: to connect to the selected transmission device. Check cables and connections. Replace Rosetta-Lt battery. If using Bluetooth: Move the HeartStart MRx closer to the external computer and re-transmit. Transmission Failed If using the Rosetta-Lt: The 12-Lead Report was not Check cables and connections. transmitted to the Rosetta- Lt. Replace Rosetta-Lt battery. Transmission Failed If using the Rosetta-Lt: Timeout The transfer did not Check cables and connections. complete within the 1-minute timeout period. Replace Rosetta-Lt battery. Transmission Failed. Connection Failed. Transmission Failed. Connection Interrupted. Cancelling a Transmission A Bluetooth Card malfunction occurred. An error occurred during transmission of one of the files. Receiving device is full. User settings in the Bluetooth device do not allow transmission To cancel a transmission in progress, perform the following: 1 From either 12-Lead Mode or Data Management Mode, press the Menu Select button. 2 Highlight Cancel Transmission and press the Menu Select button. Retry transmission. Check permissions on FTP device configurations. permissions must allow for reading and writing. Reset receiving device and retransmit. Check available space on receiving device. Set Bluetooth device to allow all operations for the HeartStart MRx and retransmit. 3 Confirm the Cancel Transmission action. Highlight Yes and press the Menu Select button to cancel; highlight No and press the Menu Select button to continue the transmission. After confirming a transmission cancellation, the HeartStart MRx displays a Disconnecting message until the cancel process is completed. Some disconnections may occur so quickly that the Disconnecting message may not be visible. 12

19 Transmitting Data Queuing Transmissions With Version 9.xx software you can queue more than one HeartStart MRx 12-Lead Report or Event Summary for transmission using the same transmission device (except the Rosetta-Lt). 12-Lead Reports can be queued to the same or different locations. If you are using the Rosetta-Lt you must complete the transmission from the HeartStart MRx to the Rosetta-Lt AND from the Rosetta-Lt to its communication device before beginning another transmission. Failure to do so results in overwriting the first transmission to the Rosetta-Lt with the second transmission. To queue another transmission while a transmission is in progress, follow the same steps you used to send the first transmission except you are not asked to select a transmission device. Your data is sent following completion of the transmission in progress. When you attempt to queue a transmission, items listed in the Send Menu which are incompatible with the current connection are unavailable and grayed out. To transmit using different transmission devices, you must complete the first transmission before initiating the next one. When a transmission fails or you cancel a transmission, any queued transmissions are cancelled and no events are logged. Finding Transmission Results When data is transmitted from the HeartStart MRx via Bluetooth File Transfer to a receiving device, it is placed in the default folder (typically located at: My Documents/Bluetooth Exchange Folder) set-up during Bluetooth configuration of the receiving device. The HeartStart MRx creates a philipsmrx folder and, depending on the data sent, a sub-folder: 12-Leads or events. The events folder contains all event data sent, including any 12-Leads sent as part of the event. Independently sent 12- Leads are contained in the 12-Leads folder. Event Summaries and 12-Lead Reports could contain information which could be considered Patient Healthcare Information (PHI) or patient identifiable data. This information can be printed or transferred from the HeartStart MRx. Please handle in accordance with HIPAA or your local patient privacy requirements. 13

20 Copy and Print Copy and Print With Version 9.xx software, you can copy and print individual 12-Lead Reports (along with Event Summaries and trending data) from Data Management Mode. Printing To print in Data Management Mode, perform the following: 1 While in Data Management Mode, use the [Prev] and [Next] softkeys to highlight the Event Summary which contains the data you want to print and press the Menu Select button. 2 Highlight Print and press the Menu Select button. 3 Select the data option listed that you want to print (see Figure 10) and press the Menu Select button to print. Figure 10 Printing in Data Management Mode Print Event Summary Trends 1-25 Apr : Apr :30 Exit Highlight Event Summary to print the selected Event Summary. Highlight Trends to bring up the Trends Interval screen and print the current Trends Report. Highlight the specific 12-Lead Report you want to print. Highlight Exit to exit the Print menu. 14

21 Copy and Print Copying To copy to the external data card in Data Management Mode, perform the following: 1 While in Data Management Mode, use the [Prev] and [Next] softkeys to highlight the Event Summary which contains the data you want to copy and press the Menu Select button. 2 Highlight Copy and press the Menu Select button. 3 Select the data option listed that you want to copy (see Figure 11) and press the Menu Select button to copy to the external data card. Figure 11 Copying in Data Management Mode Copy All Event Data 1-25 Apr : Apr :30 Exit Highlight All Event Data to copy the selected Event Summary. Highlight the specific 12-Lead Report listed to copy the selected 12-Lead Report. Highlight Exit to exit the Copy menu. If you print an event in Clinical Mode and switch to Data Management Mode, the printing must be complete before the event can be copied or sent. Failure to do so results in either a Cannot copy this event while printing or a Cannot send this event while printing message. If you get either message, wait for the printing to finish or cancel the printing before proceeding. 15

22 Latching Alarms Latching Alarms In software versions 8.xx and 9.xx, the following red alarms are latching alarms: Desat Apnea ABP, ART, Ao, PAP, P1 or P2 Disconnect The HeartStart MRx Instructions for Use labeled for use with software version 7 (identified on the book s back cover) lists these three alarms as non-latching. See Chapter 8, Pulse Oximetry - SpO 2 Alarms for Desat references; Chapter 10, Monitoring Carbon Dioxide - EtCO 2 and AwRR Alarms for Apnea references; and Chapter 11, Invasive Pressure - Alarms for Disconnect references. Latching alarms remain present regardless if the alarm condition continues to exist or not. A latching alarm is not removed until it is either acknowledged or a higher priority alarm condition for the same measurement occurs. To determine the software version running on your HeartStart MRx: 1 Turn the HeartStart MRx on and press the Menu Select button. 2 Select Other and press the Menu Select button. 3 Select Print Device Info and press the Menu Select button. The device software version will appear on the printout. If your healthcare facility has a mixed fleet of HeartStart MRx devices, please consider a method of identifying the HeartStart MRx devices with software version <7.00 code - non-latching red alarms for Desat, Apnea and ABP, ART, Ao, PAP, P1 or P2 Disconnect. Pacer Output Yellow Alarm When providing noninvasive pacing with the HeartStart MRx, if the pacer output drops below the selected setting by 20 percent or 10mA (whichever is greater), a Pacer Output Low yellow alarm is displayed on the top line of the Pacer Status block. The alarm will remain on the display until pacing is stopped, the condition clears or the therapy knob is moved off the Pacer position. A Pacer Output Low entry is logged in the Event Summary. 16

23 External Paddles Cleaning External Paddles Cleaning If external non-sterilizable paddles were used during defibrillation, make sure you thoroughly clean the paddles and paddle tray after each patient event and before performing an Operational Check or Weekly Shock Test. Verify that there is no debris or residue (including all conductive material) on the electrode surfaces of the paddles and paddle tray. External non-sterilizable paddles may be cleaned with a soft cloth moistened with: Mild soap and water. 3.4% gluteraldehyde solution such as CidexPlus Sodium hypochlorite (chlorine bleach) (3% solution in water). Quaternary ammonium compounds (21% quaternary ammonium content, such as Steris Coverage Plus NPD ), (.5 oz. per gallon water - one part Coverage Plus NPD to 255 parts water). Isopropyl alcohol (70% solution in water). CAUTION The paddles may not be ultrasonically cleaned or immersed. Also, they can t be autoclaved or ETO sterilized. Event Summary Modification With version 9.xx software, a snapshot of vital signs for heart rate, SpO 2, EtCO 2, AwRR, pulse, temperature and invasive pressure are logged to the Event Summary each five minutes after the parameter is turned on. NBP measurements are logged every time a measurement is taken. These values are independent of the values stored in the Trends table. Environmental Specifications Safety: The HeartStart M3535A and HeartStart M3536A meet UL , CSA C22.2 No , EN and standards. Recycling: This product consists of devices that may contain mercury, which must be recycled or disposed of in accordance with local, state or federal laws. (Within this system, the backlight lamps in the monitor display contain mercury.) Bluetooth Specifications The HeartStart MRx supports File Transfer Profile Server 1.1 and was tested with the following Bluetooth stacks: Toshiba , IVT (Product)/ (stack) and Widcomm For other Bluetooth stacks, review your user documentation to see if File Transfer Profile Server 1.1 is supported. If not, it is recommended that you install drivers that support File Transfer Profile Server

24 Configuration Modifications Configuration Modifications Table 5 contains a documentation modification for the upper limit of Pacing Output in Configuration Mode, found in the Manual Therapy Settings Configuration listing. The upper limit in Clinical Mode remains 175mA. Table 5 Manual Therapy Settings Parameter Description Setting Choices Pacing Output Upon entering the selected Pacer Mode (Demand or Fixed), defines the default current setting at which paced pulses are delivered , 30 (ma) adjusted in increments of 5 Table 6 contains a new configuration option for Q-CPR. It is found in the Q-CPR Settings listing in Configuration Mode. Table 6 Q-CPR Setting Parameter Description Setting Choices Q-CPR In devices with the Q-CPR option, this setting defines whether Q-CPR is configured to be off or on. On, Off WARNING For a complete list of HeartStart MRx configurable parameters and how to access Configuration Mode, see the Configuration Chapter in the HeartStart MRx Instructions for Use. The HeartStart MRx should never be connected to a patient while performing configuration activities. 18

25 Parameter Block Numerics Parameter Block Numerics With Version 9.xx software, noninvasive blood pressure numerics in Parameter Block 1 adjust in size based on the presence of temperature numerics. Invasive pressure numerics in Parameter Block 2 adjust in size based on the presence of EtCO 2 numerics. See Figure 12. Figure 12 Parameter Block Numerics Parameter Block 1 with temperature, pulse and NBP HR bpm o Temp C Pulse bpm NBP mmhg Manual SYS 11: /69 (86) 90 Parameter Block 1 with pulse and NBP HR bpm Pulse bpm NBP mmhg Manual 119/69 (93) 14:45 SYS Parameter Block 2 with invasive pressure and EtCO 2 Parameter Block 2 with invasive pressure and no EtCO 2 ABP 119/79 (95) mmhg PAP mmhg Sp02 % EtCO2 mmhg AwRR rpm SYS /10 (15) DIA ABP mmhg PAP mmhg Sp02 % SYS DIA /79 (95) 16 25/10 (15)

26 Supplies and Accessories Supplies and Accessories The HeartStart MRx has added supplies and accessories which can be used with your device. See Table 7. Table 7 Additional Supplies and Accessories 12-Lead ECG Cable Set M1663A 10-Lead ECG Patient Trunk Cable, 12-pin ECG Input Connector (for 5-Lead and 12-Lead use) 3-Lead ECG Cable Set M1669A M1671A M1672A M1673A M1674A M1675A M1678A 3-Lead Trunk Cable 3-Lead ICU Grabber (AAMI) 3-Lead ICU Grabber (IEC) 3-Lead ICU Snaps (AAMI) 3-Lead ICU Snaps (IEC) 3-Lead OR Grabber (AAMI) 3-Lead OR Grabber (IEC) 5-Lead ECG Cable Set M1668A M1968A M1971A M1644A M1645A M1973A M1974A M1976A M1978A M1979A M1984A M1602A M1604A 5-Lead Trunk Cable 5-Lead ICU Grabber (AAMI) 5-Lead ICU Grabber (IEC) 5-Lead ICU Snaps (AAMI) 5-Lead ICU Snaps (IEC) 5-Lead OR Grabber (AAMI) 5-Lead OR Grabber (IEC) 5-Lead Chest ICU Grabber (AAMI) 5-Lead Chest ICU Grabber (IEC) 5-Lead Chest OR Grabber (AAMI) 5-Lead Chest OR Grabber (IEC) 5-Lead Chest ICU Snaps (AAMI) 5-Lead Chest ICU Snaps (IEC) Bluetooth transmission Internal Bluetooth Card ECG Electrodes M4612A M4613A Solid Gel ECG Electrodes, 5 electrodes/pack (60 packs/case) Solid Gel ECG Electrodes, 30 electrodes/pack (10 packs/case) 20

27 Supplies and Accessories SpO 2 Sensors and Cables M1191T Reusable Adult Finger Sensor (Nellcor 9-pin D-sub connector) M1192T Reusable Pediatric Sensor (Nellcor 9-pin D-sub connector) M1196A Reusable Clip Adult Sensor M1196T Reusable Clip Adult Sensor (Nellcor 9-pin D-sub connector) Note: The M1903B and M1904B SpO 2 sensors are no longer on the approved supplies list for the HeartStart MRx. Their adapter (M1943A) has also been removed from the approved supplies list. Invasive Pressure Transducers* TransPac IV TruWave PX212 DTX Plus DT-4812 Disposable transducer Disposable transducer Disposable transducer * - Contact the individual manufacturers for purchasing and service information. For a complete list of HeartStart MRx supplies and accessories see the HeartStart MRx Instructions for Use. WARNING Use only supplies and accessories approved for use with your HeartStart MRx. Use of non-approved supplies and accessories could affect performance and results. WARNING Use single-use supplies and accessories only once. To order supplies and accessories: In the USA, call (pads, electrodes, cables, paper, etc.). Outside the USA, contact your local Philips Medical Systems Sales Office, your authorized Philips Medical Systems Dealer or Distributor, or visit our website at: and follow the Supplies link. 21

28 Edition 1 Philips Medical Systems Printed in the U.S.A. July 2007 * * *1*

M3535A/M3536A Instructions for Use. HeartStart MRx

M3535A/M3536A Instructions for Use. HeartStart MRx M3535A/M3536A Instructions for Use HeartStart MRx 1Table of Contents 1 Introduction 3 Overview 3 Intended Use 5 Defibrillation Therapy 5 Synchronized Cardioversion Therapy 5 Noninvasive Pacing Therapy

More information

Emergency Care Clinical Data Transmission Networks

Emergency Care Clinical Data Transmission Networks Emergency Care Clinical Data Transmission Networks Preparing for Patient Arrival and Care Application Note Send Consult Prepare The Goal: Better Information, More Informed Decisions From the moment ALS

More information

ALS life support on the run

ALS life support on the run ALS life support on the run Product Description: M3536A HeartStart MRx ALS Monitor The first thing you ll notice about the HeartStart MRx is its large, color display. Look further and you ll see that it

More information

Epilepsy Sensor Transmitter

Epilepsy Sensor Transmitter Epilepsy Sensor Transmitter Installation Guide t: 01977 661234 f: 01977 660562 e: enquiries@tunstall.com w: uk.tunstall.com Version: V0.1 (421V0R1.18) Contents 1. Features and Introduction... 3 Your Epilepsy

More information

Getting started with Wireless Fitting

Getting started with Wireless Fitting Quick Guide Getting started with Wireless Fitting Over the years, hearing aid manufacturers have introduced more cables to the clinic with the launch of new hearing aids. For dispensers, this has become

More information

TIP CARD. Model Temporary External Pacemaker

TIP CARD. Model Temporary External Pacemaker TIP CARD Model 5392 Temporary External Pacemaker PRE-USE What to do... What NOT to do... Battery Replace the battery for each new patient. Do NOT reuse battery. Physical Check case for cracks/damage.**

More information

Defibrillators TEC-8300K series. Improving quality of resuscitation

Defibrillators TEC-8300K series. Improving quality of resuscitation Defibrillators TEC-8300K series Improving quality of resuscitation Transitioning back to life For intensive treatment and advanced life support Pre-hospital Out-of-hospital 12-lead ECG acquisition and

More information

How to Use the myhearing App on Apple/iOS devices

How to Use the myhearing App on Apple/iOS devices How to Use the myhearing App on Apple/iOS devices Quick Guide Compatibility The myhearing App is compatible with all Apple devices with the ios version 9.0 and higher. Installation You can download and

More information

Sleep Apnea Therapy Software Clinician Manual

Sleep Apnea Therapy Software Clinician Manual Sleep Apnea Therapy Software Clinician Manual Page ii Sleep Apnea Therapy Software Clinician Manual Notices Revised Notice Trademark Copyright Sleep Apnea Therapy Software Clinician Manual 103391 Rev A

More information

Unitron remote control guide

Unitron remote control guide Unitron remote control guide Thank you Thank you for choosing a Unitron remote control for your Unitron hearing aids. At Unitron, we care deeply about people with hearing loss. We work closely with hearing

More information

Sleep Apnea Therapy Software User Manual

Sleep Apnea Therapy Software User Manual Sleep Apnea Therapy Software User Manual Page ii Notices Revised Notice Trademark Copyright 103392 Rev B Published February 8, 2013 and supersedes all previous versions. The information contained in this

More information

RELEASED. first steps. Icon Icon name What it means

RELEASED. first steps. Icon Icon name What it means Icon Icon name What it means Connection The connection icon appears green when the Sensor feature is on and your transmitter is successfully communicating with your pump. The connection icon appears gray

More information

PilotOne II. User Guide

PilotOne II. User Guide PilotOne II User Guide Contents 1. Welcome 4 2. Description 5 3. Using Phonak PilotOne II 6 3.1 Inserting a new battery 6 3.2 Switching On / Off 7 3.3 Holding correctly 7 3.4 Changing hearing aid volume

More information

Physio-Control LIFEPAK 15 Defibrillator Manual

Physio-Control LIFEPAK 15 Defibrillator Manual Physio-Control LIFEPAK 15 Defibrillator Manual Get an original copy of the Physio-Control LIFEPAK 15 Defibrillator Operators Guide for manufacturer information about service, available accessories and

More information

OneTouch Reveal Web Application. User Manual for Healthcare Professionals Instructions for Use

OneTouch Reveal Web Application. User Manual for Healthcare Professionals Instructions for Use OneTouch Reveal Web Application User Manual for Healthcare Professionals Instructions for Use Contents 2 Contents Chapter 1: Introduction...4 Product Overview...4 Intended Use...4 System Requirements...

More information

Fitting System Instructions for Use

Fitting System Instructions for Use Including 2017 2018.2 Fitting System Instructions for Use Version 1.0 www.sonici.com Table of contents 1. Introduction 4 2. Installation 5 3. System requirements 6 4. Getting started with Expressfit Pro

More information

Share/Follow. User Guide. A feature of Dexcom G5 Mobile CGM System

Share/Follow. User Guide. A feature of Dexcom G5 Mobile CGM System Share/Follow User Guide A feature of Dexcom G5 Mobile CGM System IMPORTANT USER INFORMATION Please review your product instructions before using your continuous glucose monitoring system. Contraindications,

More information

Attenti One-Piece Tracking Device 4

Attenti One-Piece Tracking Device 4 Attenti One-Piece Tracking Device 4 User Manual January 16, 2018 1 Piece (Gen 4) User Manual 2 Copyright 2018 Attenti. All rights reserved. No part of this publication may be reproduced, stored in a retrieval

More information

User Manual CentrePoint Data Hub

User Manual CentrePoint Data Hub User Manual CentrePoint Data Hub CentrePoint Data Hub Revision: 0 Released: 07//07 User Manual CentrePoint Data Hub CentrePoint Data Hub Revision: 0 Released: 07//07 Contents Overview Getting Started Assigning

More information

Phonak PilotOne II. User Guide

Phonak PilotOne II. User Guide Phonak PilotOne II User Guide Contents 1. Welcome 4 2. Description 5 3. Using Phonak PilotOne II 6 3.1 Inserting a new battery 6 3.2 Switching On/Off 7 3.3 Holding PilotOne II 7 3.4 Changing hearing aid

More information

Evolve 3 & 5 Service Manual

Evolve 3 & 5 Service Manual Evolve 3 & 5 Service Manual 1 Product Browse 2 Contents CHAPTER 1: SERIAL NUMBER LOCATION... 5 CHAPTER 2: CONSOLE INSTRUCTIONS 2.1 Console Overview... 6 2.1.1 Evolve 3 Console Overview... 6 2.1.2 Evolve

More information

ECG Check Wireless 1- Lead Cardiac Monitor. Rx Use

ECG Check Wireless 1- Lead Cardiac Monitor. Rx Use ECG Check Wireless 1- Lead Cardiac Monitor Rx Use Dear ECG Check Owner: Thank you for selecting the ECG Check cardiac monitor. This user guide includes information and instructions about your new ECG Check

More information

Dosimeter Setting Device

Dosimeter Setting Device Instruction Manual Dosimeter Setting Device For Electronic Personal Dosimeter Dose-i (Unit:Sv, Version:1.05 English) WTA529748 a 1 / 38 Foreword Thank you for purchasing the Dosimeter Setting Device; a

More information

User Manual. RaySafe i2 dose viewer

User Manual. RaySafe i2 dose viewer User Manual RaySafe i2 dose viewer 2012.03 Unfors RaySafe 5001048-A All rights are reserved. Reproduction or transmission in whole or in part, in any form or by any means, electronic, mechanical or otherwise,

More information

COPYRIGHT Ramsey Medical, Inc.

COPYRIGHT Ramsey Medical, Inc. Now your petmap+ii can monitor ECG 1 This manual applies to the operation of the ECG Module (REF# 9026), available as an option with the petmap+ii. The ECG Module requires a petmap+ii to be useful. Read

More information

Laerdal-SonoSim Procedure Trainer

Laerdal-SonoSim Procedure Trainer EN Laerdal-SonoSim Procedure Trainer User Guide www.laerdal.com Intended Use The Laerdal-SonoSim Procedure Trainer allows learners the ability to perform ultrasound guidance with real-patient data on multiple

More information

myphonak app User Guide

myphonak app User Guide myphonak app User Guide Getting started myphonak is an app developed by Sonova, the world leader in hearing solutions based in Zurich, Switzerland. Read the user instructions thoroughly in order to benefit

More information

Unitron Remote Plus app

Unitron Remote Plus app Unitron Remote Plus app User Guide A Sonova brand Getting started Intended use The Unitron Remote Plus app is intended for hearing aids users to adjust certain aspects of Unitron hearing aids through Android

More information

Multiple Diagnostic Interface (MDI) User Guide

Multiple Diagnostic Interface (MDI) User Guide Multiple Diagnostic Interface (MDI) User Guide 2014 GM Customer Care and Aftersales. Made in the U.S.A. All rights reserved. MDI is a registered trademark of General Motors. 1 Important Information Everything

More information

Defibrillators TEC-8300K series. It s all seamless

Defibrillators TEC-8300K series. It s all seamless Defibrillators TEC-8300K series It s all seamless The one you need in an emergency ECG, SpO 2, NIBP, MULTI connectors, Pacing* * Pacing available with TEC-8332K/8352K Pre-hospital Out-of-hospital 12-lead

More information

User s Manual. Model No. NTMPADS15.0 Model No. NTMPAD16.0

User s Manual. Model No. NTMPADS15.0 Model No. NTMPAD16.0 User s Manual Model No. NTMPADS15.0 Model No. NTMPAD16.0 Table of Contents Important Precautions...1 Quickstart Guide...2 Questions?... 3 Before you Begin... 3 Install The ifit Sleep App And Pair The Sensor

More information

ALS life support on the run. Philips M3536A HeartStart MRx monitor defibrillator

ALS life support on the run. Philips M3536A HeartStart MRx monitor defibrillator ALS life support on the run Philips M3536A HeartStart MRx monitor defibrillator Leading the way with meaningful innovations in emergency care. Clinical decision support that positively impacts patient

More information

Phonak RemoteControl App. User Guide

Phonak RemoteControl App. User Guide Phonak RemoteControl App User Guide Getting started The RemoteControl App is developed by Phonak, one of the world`s leading companies in hearing technology. Read this user instructions thoroughly in order

More information

RaySafe i3 INSTALLATION & SERVICE MANUAL

RaySafe i3 INSTALLATION & SERVICE MANUAL RaySafe i3 INSTALLATION & SERVICE MANUAL 2017.06 Unfors RaySafe 5001104-1.1 All rights are reserved. Reproduction or transmission in whole or in part, in any form or by any means, electronic, mechanical

More information

Lionbridge Connector for Hybris. User Guide

Lionbridge Connector for Hybris. User Guide Lionbridge Connector for Hybris User Guide Version 2.1.0 November 24, 2017 Copyright Copyright 2017 Lionbridge Technologies, Inc. All rights reserved. Published in the USA. March, 2016. Lionbridge and

More information

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at Connevans.info Solutions to improve the quality of life Offering you choice Helping you choose This product may be purchased from Connevans Limited secure online store at www.deafequipment.co.uk DeafEquipment.co.uk

More information

easypocket Version 2 User Guide Life sounds brilliant.

easypocket Version 2 User Guide  Life sounds brilliant. easypocket Version 2 User Guide www.bestsound-technology.co.uk Life sounds brilliant. Content Your remote control 4 Overview 5 Display 6 Control buttons 8 Key lock switch 10 Programming connection 10 Batteries

More information

HANSATON stream remote App User Guide. HANSATON stream remote App User Guide

HANSATON stream remote App User Guide. HANSATON stream remote App User Guide HANSATON stream remote App Getting started Intended use The HANSATON stream remote App is intended for hearing aids users to adjust certain aspects of HANSATON hearing aids through Android and Apple ios

More information

Dosimeter Setting Device System NRZ

Dosimeter Setting Device System NRZ User s Manual Dosimeter Setting Device System NRZ For Dosimeter NRF series (Units: msv Version:0.26 English) TA5C0903 b 1 / 50 Preface Thank you for purchasing the Dosimeter Setting Device; a product by

More information

Cloud Condensation Nuclei Counter (CCN) Module

Cloud Condensation Nuclei Counter (CCN) Module Particle Analysis and Display System (PADS): Cloud Condensation Nuclei Counter (CCN) Module Operator Manual DOC-0190 A-1 PADS 2.5.6, CCN Module 2.5.1 5710 Flatiron Parkway, Unit B Boulder, CO 80301 USA

More information

A. User s Guide. CareCenter MD Stress and Resting ECG

A. User s Guide. CareCenter MD Stress and Resting ECG 70-00533-02 A User s Guide CareCenter MD Stress and Resting ECG CARECENTER MD STRESS AND RESTING USER S GUIDE 70-00533-02 A Information in this document is subject to change without notice. Names and data

More information

User Manual second language

User Manual second language User Manual second language GlucoTel Blood Glucose Monitoring and Diabetes Management System must be used with cell phones that have: Table of contents 2 3 Introduction 4 Bluetooth Wireless Technology

More information

Addendum: User Guide AutoPulse Resuscitation System Model 100 with Defibrillator Interface

Addendum: User Guide AutoPulse Resuscitation System Model 100 with Defibrillator Interface Addendum: User Guide AutoPulse Resuscitation System Model 100 with Defibrillator Interface 3.5 Periodic Electrocardiogram (ECG) Monitoring and/or Defibrillation When the AutoPulse is used in conjunction

More information

Directions for Use. CardioPerfect Webstation 2.0

Directions for Use. CardioPerfect Webstation 2.0 Directions for Use CardioPerfect Webstation 2.0 Welch Allyn 4341 State Street Road Skaneateles Falls, NY 13153-0220 USA www.welchallyn.com European Regulatory Representative Welch Allyn Limited Navan Business

More information

Contour Diabetes app User Guide

Contour Diabetes app User Guide Contour Diabetes app User Guide Contents iii Contents Chapter 1: Introduction...5 About the CONTOUR DIABETES app...6 System and Device Requirements...6 Intended Use...6 Chapter 2: Getting Started...7

More information

Remote control 2 guide

Remote control 2 guide Remote control 2 guide Thank you Thank you for choosing remote control 2 for your Unitron hearing aids. At Unitron, we care deeply about people with hearing loss. We work closely with hearing healthcare

More information

HeartStart. XL+ cardiac resuscitation. Ready. to save lives. Not available for sale in the U.S.

HeartStart. XL+ cardiac resuscitation. Ready. to save lives. Not available for sale in the U.S. HeartStart XL+ cardiac resuscitation Ready to save lives Not available for sale in the U.S. Ready to respond, revive, improve Hospital cardiac emergencies are typically stressful and chaotic events. The

More information

Bio-logic AuDX PRO FLEX Screening tympanometry and audiometry Quick start guide

Bio-logic AuDX PRO FLEX Screening tympanometry and audiometry Quick start guide AuDX PRO FLEX Screening tympanometry and audiometry Quick start guide Doc. No.7-26-1374-EN/00 Part No.7-26-13704-EN Natus Medical Denmark ApS. +45 45 75 55 55. otoinfo@natus.com Natus Medical Incorporated.

More information

Florida Standards Assessments

Florida Standards Assessments Florida Standards Assessments Assessment Viewing Application User Guide 2017 2018 Updated February 9, 2018 Prepared by the American Institutes for Research Florida Department of Education, 2018 Descriptions

More information

Software Version 2.0. User s Guide

Software Version 2.0. User s Guide Software Version 2.0 User s Guide Table of Contents Contents Contents Important Information About Your FreeStyle Auto-Assist Software...1 Intended Use...1 System Requirements...1 Connecting to your Abbott

More information

PATIENT PROGRAMMER 37642

PATIENT PROGRAMMER 37642 PATIENT PROGRAMMER 37642 Medtronic DBS Therapy user manual Activa PC Model 37601 Activa RC Model 37612 Activa SC Model 37602 Activa SC Model 37603! USA Rx only 2008 Medtronic, Activa, and SoftStart/Stop

More information

Diabetes Management App. Instruction Manual

Diabetes Management App. Instruction Manual Diabetes Management App Instruction Manual Accu-Chek Connect Diabetes Management App Overview The Accu-Chek Connect diabetes management app (hereafter referred to as the app) is designed to help you: Transfer

More information

Clay Tablet Connector for hybris. User Guide. Version 1.5.0

Clay Tablet Connector for hybris. User Guide. Version 1.5.0 Clay Tablet Connector for hybris User Guide Version 1.5.0 August 4, 2016 Copyright Copyright 2005-2016 Clay Tablet Technologies Inc. All rights reserved. All rights reserved. This document and its content

More information

CP lead resting electrocardiograph

CP lead resting electrocardiograph CP 150 12-lead resting electrocardiograph Quick reference guide 2013 Welch Allyn, Inc. To support the intended use of the product described in this publication, the purchaser of the product is permitted

More information

Your umic. Thank you. Hearing healthcare professional: Telephone: Serial number of umic: Warranty: Date of purchase:

Your umic. Thank you. Hearing healthcare professional: Telephone: Serial number of umic: Warranty: Date of purchase: umic guide Thank you Thank you for choosing the Unitron umic. At Unitron, we care deeply about people with hearing loss. We work closely with hearing healthcare professionals to make advanced, purpose-driven

More information

For Electric Personal Dosimete Dose-i

For Electric Personal Dosimete Dose-i Instruction Manual Dosime eter Setting Device For Electric Personal Dosimete er Dose-i (Unit:rem, Version:1.05 English) Issued on March 2015 WTA529893 1 / 38 Foreword Thank you for purchasing the Dosimeter

More information

ECG Check Universal Wireless 1-Lead Cardiac Monitor. OTC Use

ECG Check Universal Wireless 1-Lead Cardiac Monitor. OTC Use ECG Check Universal Wireless 1-Lead Cardiac Monitor OTC Use 100 Bush Street Suite 1450 San Francisco, CA 94104 Tel: 844-324-2432 Email: info@cardiacdesigns.com Website: www.cardiacdesigns.com Welcome Thank

More information

Nitelog. User Manual. For use with the Z1 Auto CPAP System

Nitelog. User Manual. For use with the Z1 Auto CPAP System Nitelog User Manual For use with the Z1 Auto CPAP System Thank you for choosing the Z1 Auto TM CPAP System from Human Design Medical, LLC. This Nitelog User Manual provides information as to how to use

More information

Communications Accessibility with Avaya IP Office

Communications Accessibility with Avaya IP Office Accessibility with Avaya IP Office Voluntary Product Accessibility Template (VPAT) 1194.23, Telecommunications Products Avaya IP Office is an all-in-one solution specially designed to meet the communications

More information

12-Lead ECG Monitoring

12-Lead ECG Monitoring 12-Lead ECG Monitoring October 2008 9650-1213-01 Rev. G The issue date or revision level for this operation guide is shown on the front cover. ZOLL and E Series are registered trademarks of ZOLL Medical

More information

Power to see the big picture

Power to see the big picture Power to see the big picture Philips HeartStart MRx Monitor/Defibrillator Product information The capabilities you need and the performance HeartStart MRx unites Philips industry-leading monitoring with

More information

DreamStation. Provider guide

DreamStation. Provider guide Provider guide Accessing the Provider mode screens Accessing Provider mode unlocks settings that cannot be modified by the user. To access Provider mode: 1. ce the device is powered, press and hold both

More information

Monitoring Equipment. Blood Pressure Monitor Upper Arm Type: Image (Image not to scale)

Monitoring Equipment. Blood Pressure Monitor Upper Arm Type: Image (Image not to scale) Monitoring Equipment Blood Pressure Monitor Upper Arm Type: Order # Description BP500 LCD Size: 40mm x 60mm Blood pressure classification (WHO) indicator; HAD technology (Heart Arrhythmia Detection) Time

More information

Desktop Fitting Guide for Phonak Brio 3

Desktop Fitting Guide for Phonak Brio 3 Phonak Target 5.3.3 Desktop Fitting Guide for Phonak Brio 3 The Phonak Target fitting software is intended to be used by qualified hearing care professionals to configure, program, and fit hearing aids

More information

Provider guide. DreamStation CPAP DreamStation CPAP Pro DreamStation Auto CPAP DreamStation BiPAP Pro DreamStation Auto BiPAP

Provider guide. DreamStation CPAP DreamStation CPAP Pro DreamStation Auto CPAP DreamStation BiPAP Pro DreamStation Auto BiPAP Provider guide DreamStation CPAP DreamStation CPAP Pro DreamStation Auto CPAP DreamStation BiPAP Pro DreamStation Auto BiPAP IMPORTANT! Remove this guide before giving the device to the patient. Only medical

More information

Table of Contents. Contour Diabetes App User Guide

Table of Contents. Contour Diabetes App User Guide Table of Contents Introduction... 3 About the CONTOUR Diabetes App... 3 System and Device Requirements... 3 Intended Use... 3 Getting Started... 3 Downloading CONTOUR... 3 Apple... 3 Android... 4 Quick

More information

X Series Extensive Capabilities

X Series Extensive Capabilities X Series Extensive Capabilities for Patient Transport Transporting Patients throughout the Hospital Requires the Right Equipment Full Featured yet Compact When transporting critically ill patients, you

More information

MODEL EPG SINGLE CHAMBER TEMPORARY EXTERNAL PACEMAKER

MODEL EPG SINGLE CHAMBER TEMPORARY EXTERNAL PACEMAKER MODEL 53401 EPG SINGLE CHAMBER TEMPORARY EXTERNAL PACEMAKER In-service Guide 53401 TRAINING LEARNING OBJECTIVES Identify the control knobs and be able to explain how to use them to program device. Distinguish

More information

Agile Product Lifecycle Management for Process

Agile Product Lifecycle Management for Process Nutrition Surveillance Management User Guide Release 5.2.1 Part No. E13901-01 September 2008 Copyrights and Trademarks Copyright 1995, 2008, Oracle Corporation and/or its affiliates. All rights reserved.

More information

Mini Remote Microphone OPERATIONS MANUAL

Mini Remote Microphone OPERATIONS MANUAL Mini Remote Microphone OPERATIONS MANUAL Table of Contents Overview..................................... 4 Basic Use..................................... 7 Daily Use.....................................

More information

Pure 312 Nx, Pure 13 Nx

Pure 312 Nx, Pure 13 Nx Pure 312 Nx, Pure 13 Nx User Guide Hearing Systems Content Welcome 4 Your hearing instruments 5 Instrument type 5 Getting to know your hearing instruments 6 Components and names 7 Controls 10 Hearing programs

More information

ihealth PO3 Fingertip Pulse Oximeter OPERATION GUIDE INDEX

ihealth PO3 Fingertip Pulse Oximeter OPERATION GUIDE INDEX ihealth PO3 Fingertip Pulse Oximeter OPERATION GUIDE INDEX INTRODUCTION AND INTENDED USE...2 CONTENTS AND DISPLAY INDICATORS...2 PRODUCT DESCRIPTION...3 SPECIFICATIONS...3 CAUTIONS...3 Cautions...3 USING

More information

Resting and Stress ECG

Resting and Stress ECG Operating Manual Resting and Stress ECG 1 Safety 2 Hardware 3 Software 4 Hygiene Part 3: Operating characteristics: custo diagnostic 5.0 and higher for Windows MSW 0001 DK 1660 Version 002 13/06/2018 2018

More information

Voluntary Product Accessibility Template (VPAT)

Voluntary Product Accessibility Template (VPAT) Avaya Vantage TM Basic for Avaya Vantage TM Voluntary Product Accessibility Template (VPAT) Avaya Vantage TM Basic is a simple communications application for the Avaya Vantage TM device, offering basic

More information

Experiment HE-12: Targeted Exercise with Wireless Electrocardiogram (ECG)

Experiment HE-12: Targeted Exercise with Wireless Electrocardiogram (ECG) Experiment HE-12: Targeted Exercise with Wireless Electrocardiogram (ECG) Get Your Cardio On Preparations for this experiment need to be reviewed with the students in advance. There will be exercise routines

More information

Dr FuelCell Load Measurement Box

Dr FuelCell Load Measurement Box 1 (855) 251-0016 sales@fuelcellstore.com Dr FuelCell Load Measurement Box Instruction Manual www.fuelcellstore.com Instruction Manual for Dr FuelCell TM Load Measurement Box Version 1.0.1 November 2008

More information

RELEASED. Clearing your active insulin

RELEASED. Clearing your active insulin To clear all your settings: 1. Make sure the pump is not connected to your body. 2. Go to the Manage Settings screen. Menu > Utilities > Manage Settings 3. Simultaneously press and hold and until the Manage

More information

ReSound Forte and ReSound Smart 3D App For Android Users Frequently Asked Questions

ReSound Forte and ReSound Smart 3D App For Android Users Frequently Asked Questions ReSound Forte and ReSound Smart 3D App For Android Users Frequently Asked Questions GENERAL Q. I have an Android phone. Can I use ReSound Forte? Q. What Android devices are compatible with ReSound Forte

More information

Data Management System (DMS) User Guide

Data Management System (DMS) User Guide Data Management System (DMS) User Guide Eversense and the Eversense logo are trademarks of Senseonics, Incorporated. Other brands and their products are trademarks or registered trademarks of their respective

More information

Model 5392 EPG Temporary Pacer

Model 5392 EPG Temporary Pacer Model 5392 EPG Temporary Pacer Compatible Components Reference Card 5392 Surgical Cables 5487 Disposable, short 5487L Disposable, long 5832S Reusable, small clip 5833S 5833SL Disposable, small clip, short

More information

Installation Instructions

Installation Instructions Installation Instructions 1View Manager 96 Enhanced OUCH RACKER Contents About his Document...1 Planning the OUCH RACKER Network...1 Backbone Network Guidelines...2 Star Network Guidelines...2 Installing

More information

ProPocket TM. User Guide

ProPocket TM. User Guide ProPocket TM User Guide A1 A Introduction Dear customer, Your hearing instruments are equipped with wireless technology and can therefore be controlled by your ProPocket. These instruction describes how

More information

Provider guide. DreamStation

Provider guide. DreamStation Provider guide DreamStation CPAP CPAP Pro Auto CPAP BiPAP Pro Auto BiPAP IMPORTANT! Remove this guide before giving the device to the patient. Only medical professionals should adjust pressure settings.

More information

ERS 2 CARDIAC REHABILITATION M O V I N G T O H E A L T H

ERS 2 CARDIAC REHABILITATION M O V I N G T O H E A L T H ERS 2 CARDIAC REHABILITATION M O V I N G T O H E A L T H Therapy by design One of the major goals of cardiac rehabilitation is to systematically improve the performance of the cardiovascular system. The

More information

SLEEP IMPROVING WRISTBAND. Item No Owner s Guide

SLEEP IMPROVING WRISTBAND. Item No Owner s Guide SLEEP IMPROVING WRISTBAND Item No. 205350 Owner s Guide Thank you for purchasing the Sharper Image Sleep Improving Wristband. Based on ancient Chinese acupuncture principles, this biofeedback device uses

More information

User s Manual for Eclipse(AccuCap)

User s Manual for Eclipse(AccuCap) InnoCaption Agent Program User s Manual for Eclipse(AccuCap) VER 2.1.4 InnoCaptionAgent Ver 2.1.4 2015-10-12 InnoCaption 1 / 24 InnoCaption Agent User s Manual for Eclipse Table of Contents 1. GENERAL...

More information

HeroTracker Sensor for Diskus Instruction Manual

HeroTracker Sensor for Diskus Instruction Manual HeroTracker Sensor for Diskus Instruction Manual Table of Contents Intended use... 1 Product description... 1 Installation... 3 Usage... 5 Transferring to a new inhaler... 6 Precautions and warnings...

More information

Mini Pulse Electronic Stimulator

Mini Pulse Electronic Stimulator Mini Pulse Electronic Stimulator Model: PM-180 Operating Manual IMPORTANT: Please read all instructions before using this product. Retain this manual for future reference. www.santamedical.com IMPORTANT

More information

MNSCREEN TRAINING MANUAL Hospital Births Newborn Screening Program October 2015

MNSCREEN TRAINING MANUAL Hospital Births Newborn Screening Program October 2015 MNSCREEN TRAINING MANUAL Hospital Births Newborn Screening Program October 2015 CONTENTS PART 1: GETTING STARTED... 2 Logging In... 2 Access for New Hires... 2 Reporting Refusals... 3 Adding Patient Records...

More information

Dear HighQ Check System Owner :

Dear HighQ Check System Owner : Dear HighQ Check System Owner : Thank you for purchasing the HighQ Check Blood Glucose Monitoring System. This manual provides important information to help you to use the system properly. Before using

More information

SENSATION and CS300 Smaller meets faster. IABP System

SENSATION and CS300 Smaller meets faster. IABP System SENSATION and CS300 Smaller meets faster IABP System Cardiac Assist SENSATION and CS300 3 Cardiac Assist SENSATION and CS300 5 Smaller The SENSATION 7Fr. Fiber-Optic IAB Catheter Faster The CS300 with

More information

RESULTS REPORTING MANUAL. Hospital Births Newborn Screening Program June 2016

RESULTS REPORTING MANUAL. Hospital Births Newborn Screening Program June 2016 RESULTS REPORTING MANUAL Hospital Births Newborn Screening Program June 2016 CONTENTS GETTING STARTED... 1 Summary... 1 Logging In... 1 Access For New Hires... 2 Reporting Parental Refusals... 3 Adding

More information

Cortex Gateway 2.0. Administrator Guide. September Document Version C

Cortex Gateway 2.0. Administrator Guide. September Document Version C Cortex Gateway 2.0 Administrator Guide September 2015 Document Version C Version C of the Cortex Gateway 2.0 Administrator Guide had been updated with editing changes. Contents Preface... 1 About Cortex

More information

Proteome Discoverer Version 1.3

Proteome Discoverer Version 1.3 Xcalibur Proteome Discoverer Version 1.3 Installation Guide XCALI-97359 Revision A May 2011 2011 Thermo Fisher Scientific Inc. All rights reserved. Xcalibur is a registered trademark of Thermo Fisher Scientific

More information

Avaya one-x Communicator for Mac OS X R2.0 Voluntary Product Accessibility Template (VPAT)

Avaya one-x Communicator for Mac OS X R2.0 Voluntary Product Accessibility Template (VPAT) Avaya one-x Communicator for Mac OS X R2.0 Voluntary Product Accessibility Template (VPAT) Avaya one-x Communicator is a unified communications client that allows people to communicate using VoIP and Contacts.

More information

Seven Simple Steps to Start. Your Dexcom G4 PLATINUM System

Seven Simple Steps to Start. Your Dexcom G4 PLATINUM System Seven Simple Steps to Start Your Dexcom G4 PLATINUM System Receiver Sensor Applicator Transmitter Sensor Remove transmitter from tray and wait 10 minutes Do Not Throw Away Battery life ~ 6 months Charging

More information

GLOOKO FOR ios MIDS USER GUIDE

GLOOKO FOR ios MIDS USER GUIDE GLOOKO FOR ios MIDS USER GUIDE October 2018 IFU-0001 13 Glooko MIDS is cleared for US only Rx only TABLE OF CONTENTS TABLE OF CONTENTS MOBILE INSULIN DOSING SYSTEM (MIDS)... 2 Intended Use... 2 Warnings...

More information

Blood Glucose Monitoring System. User Guide

Blood Glucose Monitoring System. User Guide Blood Glucose Monitoring System User Guide Table of Contents Introduction...2 Important Safety Instructions...2 About ipet PRO Blood Glucose Monitoring System...3 About ipet PRO Meter...4 About the ipet

More information

Glucose Meter. User Guide. Veterinary Monitoring System. For dog and cat use only

Glucose Meter. User Guide. Veterinary Monitoring System. For dog and cat use only Glucose Meter User Guide Veterinary Monitoring System For dog and cat use only Gpet instruction Manual 31/5/09 18:06 Page 2 Gpet instruction Manual 31/5/09 18:06 Page 3 TABLE OF CONTENTS Your g-pet system

More information

6. If I already own another brand Videophone, can I use it with the ACN Digital Phone Service? No.

6. If I already own another brand Videophone, can I use it with the ACN Digital Phone Service? No. FAQs ACN Digital Phone Service General 1. What do I need in order to benefit from ACN Digital Phone Service? You will need the following to benefit from this innovative service: - A credit card for the

More information