AMBULATORY BLOOD PRESSURE REPORT. Patient Name: Sample 2 - Systolic Hypertension Patient ID: Test Date: 15-Sep-2005

Size: px
Start display at page:

Download "AMBULATORY BLOOD PRESSURE REPORT. Patient Name: Sample 2 - Systolic Hypertension Patient ID: Test Date: 15-Sep-2005"

Transcription

1 Interpretive Summary Based upon JNC 7 and AHA recommendations, the ABPM data suggests 24 hour SYS hypertension (136 mmhg) with normal 24 hour DIA pressure (73 mmhg) Awake SYS hypertension (138 mmhg) with normal awake DIA pressure (74 mmhg) Asleep SYS hypertension (126 mmhg) with normal asleep DIA pressure (68 mmhg) Asleep dip is 8.7% SYS and 7.9% DIA, Non-Dipper (abnormal) Period Time Samples Mean Sys Mean Dia Mean HR BP Load Sys BP Load Dia mmhg mmhg BPM % % (+/- Std.Dev.) (+/- Std.Dev.) (+/- Std.Dev.) Overall 17:30-17:12 (23:42) (7.8) 73 (3.9) 54 (2.9) 55 0 Awake Period 07:00-22: (6.4) 74 (2.5) 54 (2.9) 44 0 Asleep Period 22:00-07: (4.3) 68 (4.5) 55 (2.9) 92 0 Asleep Dip: Sys = 8.7% Dia = 7.9% Current Medications Norvasc 5mg daily Toprol-XL 47.5mg daily Lipitor 20mg daily Prevacid 30mg daily Ambien 5mg as needed Physician Interpretation ABPM shows systolic hypertension throughout the 24 hour period. Adjust medication and therapy accordingly. Follow up with another ABPM in 2 weeks to assure proper control. Referring physician: Dr. White Interpreting physician: Dr. Green Signature Date Signature Date Ambulatory Blood Pressure report: Oscar 2 Copyright SunTech Medical, Inc. Page 1 of 6

2 Patient Information Date of Birth: 7 Mar 1955 Address: 11 Slater Drive Sacramento, CA USA Telephone: Sex: Female Race: White Height: 5' 4" Weight: 145 History Patient has a history of hypertension. Anti-hypertensive medications for previous 4 years. Recent office visits have shown high SYS pressures. ABPM to review 24 hour management of Systolic pressure. Reason for Test Concern over 24 hour management of systolic hypertension. Ambulatory Blood Pressure report: Oscar 2 Copyright SunTech Medical, Inc. Page 2 of 6

3 ABPM Statistics Overall Time: 17:30-17:12 Duration: 23:42 Samples: 53 of 53 (100%) Mean Std. Dev. Max (time) Min (time) Systolic (mmhg) 136 +/ (16:49) 118 (23:39) Diastolic (mmhg) 73 +/ (08:36) 60 (23:39) Heart rate (bpm) 54 +/ (18:54) 50 (17:30) MAP (mmhg) 94 +/ (20:41) 79 (23:39) Pulse pressure (mmhg) 63 +/ (18:33) 52 (00:28) BP Load: 55% of SYS readings > 140 mmhg awake and > 120 mmhg asleep 0% of DIA readings > 90 mmhg awake and > 80 mmhg asleep Asleep Dip: 8.7% SYS and 7.9% DIA reductions during sleep. Awake Period Time: 07:00-22:00 Samples: 41 of 41 (100%) Mean Std. Dev. Max (time) Min (time) Systolic (mmhg) 138 +/ (16:49) 121 (07:33) Diastolic (mmhg) 74 +/ (08:36) 68 (19:57) Heart rate (bpm) 54 +/ (18:54) 50 (17:30) MAP (mmhg) 96 +/ (20:41) 86 (07:33) Pulse pressure (mmhg) 64 +/ (18:33) 53 (17:30) BP Load: 44% of SYS readings > 140 mmhg 0% of DIA readings > 90 mmhg Asleep Period Time: 22:00-07:00 Samples: 12 of 12 (100%) Mean Std. Dev. Max (time) Min (time) Systolic (mmhg) 126 +/ (05:58) 118 (23:39) Diastolic (mmhg) 68 +/ (00:28) 60 (23:39) Heart rate (bpm) 55 +/ (22:53) 50 (23:39) MAP (mmhg) 88 +/ (05:58) 79 (23:39) Pulse pressure (mmhg) 58 +/ (06:45) 52 (00:28) BP Load: 92% of SYS readings > 120 mmhg 0% of DIA readings > 80 mmhg Ambulatory Blood Pressure report: Oscar 2 Copyright SunTech Medical, Inc. Page 3 of 6

4 Oscar 2 ABP data ABP data Edited ABP Data # Time Sys/Dia HR MAP EC Comment (mmhg) (BPM) (mmhg) 1 17:30 130/ :51 141/ 73 > :11 138/ :33 146/ 72 > :54 137/ :15 144/ 76 > :36 136/ :57 128/ :17 135/ :41 147/ 76 > :01 132/ :21 130/ :44 136/ :05 132/ 70 > :53 128/ 66 > :39 118/ :28 126/ 74 > :16 124/ 72 > :05 125/ 66 > :50 128/ 72 > :39 124/ 68 > :27 127/ 66 > :13 124/ 68 > :58 135/ 74 > :45 126/ 62 > :33 121/ :53 134/ :14 130/ :36 144/ 78 > :56 131/ :16 134/ Ambulatory Blood Pressure report: Oscar 2 Copyright SunTech Medical, Inc. Page 4 of 6

5 Edited ABP Data (continued) # Time Sys/Dia HR MAP EC Comment (mmhg) (BPM) (mmhg) 32 09:37 146/ 73 > :58 143/ 77 > :19 135/ :42 144/ 74 > :04 147/ 76 > :24 138/ :44 143/ 72 > :08 143/ 77 > :29 144/ 74 > :52 134/ :13 142/ 73 > :33 147/ 75 > :56 143/ 72 > :17 140/ :39 136/ :01 144/ 76 > :21 139/ :45 134/ :07 142/ 77 > :29 138/ :49 149/ 75 > :12 131/ Omitted ABP Data # Time Sys/Dia HR MAP EC Comment (mmhg) (BPM) (mmhg) No data to report. Ambulatory Blood Pressure report: Oscar 2 Copyright SunTech Medical, Inc. Page 5 of 6

6 Monitor System Configuration Monitor type: Oscar 2 Start key: Off Firmware version: Max pressure: --- Display: Off AccuWin version: Time Periods Time Period Interval Sleep Period 00:00 to 00:00 0 mins 22:00 to 07:00 00:00 to 00:00 0 mins Event Code Definitions Event Code (EC) 1 = No signal 2 = Artifact/Erratic signal 3 = Retries exceeded 4 = Time limit exceeded 85 = Blocked valve 86 = User abort 87 = Air leak 88 = Safety timeout 89 = Cuff overpressure 90 = Low batteries 91 = Auto-zero failed 97 = Transducer failed 98 = ADC failure 99 = CRC failure See Operations Manual for AccuWin Pro for further details on code descriptions. v Ambulatory Blood Pressure report: Oscar 2 Copyright SunTech Medical, Inc. Page 6 of 6

AMBULATORY BLOOD PRESSURE REPORT protocol xyz Address

AMBULATORY BLOOD PRESSURE REPORT protocol xyz Address Patient Information : 23 Franklin Street New Orleans, LA 70115 Telephone: 414-959-1234 Date of Birth: 11 Feb 1949 Sex: Female Race: African-American Height: 5' 4" Weight: 185 Physician Information Referring

More information

SpO2 Report---Summary Report

SpO2 Report---Summary Report SpO2 Report---Summary Report Event Data SpO2 Pulse Total Events 481 Time in Events(min) 25.3 136.0 Avg. Event Dur.(Sec) 25.3 17.0 Index(1/hr) 1.3 10.6 % Artifact 1.7 13.6 Adjusted Index(1/hr) 1.7 13.6

More information

Ambulatory BP Monitoring: Getting the Diagnosis of Hypertension Right. Anthony J. Viera, MD, MPH, FAHA Professor and Chair

Ambulatory BP Monitoring: Getting the Diagnosis of Hypertension Right. Anthony J. Viera, MD, MPH, FAHA Professor and Chair Ambulatory BP Monitoring: Getting the Diagnosis of Hypertension Right Anthony J. Viera, MD, MPH, FAHA Professor and Chair Objectives Review limitations of office BP in making a correct diagnosis of hypertension

More information

Assessing Blood Pressure for Clinical Research: Pearls & Pitfalls

Assessing Blood Pressure for Clinical Research: Pearls & Pitfalls Assessing Blood Pressure for Clinical Research: Pearls & Pitfalls Anthony J. Viera, MD, MPH, FAHA Department of Family Medicine Hypertension Research Program UNC School of Medicine Objectives Review limitations

More information

Welch Allyn ABPM 6100S. Comprehensive blood pressure monitoring that brings patient comfort home.

Welch Allyn ABPM 6100S. Comprehensive blood pressure monitoring that brings patient comfort home. Welch Allyn ABPM 6100S Comprehensive blood pressure monitoring that brings patient comfort home. Features and Benefits of the Welch Allyn ABPM 6100S Pictorial application instructions, artery markers and

More information

Clinical Medical Policy Department Clinical Affairs Division DESCRIPTION

Clinical Medical Policy Department Clinical Affairs Division DESCRIPTION Ambulatory Blood Pressure Monitoring (ABPM) [For the list of services and procedures that need preauthorization, please refer to www.mcs.com.pr. go to Comunicados a Proveedores, and click Cartas Circulares.]

More information

Ambulo Ambulatory Blood Pressure Monitoring Systems. Innovative Diagnostics Better Care

Ambulo Ambulatory Blood Pressure Monitoring Systems. Innovative Diagnostics Better Care Ambulo 2400 Ambulatory Blood Pressure Monitoring Systems Innovative Diagnostics Better Care About Tiba Medical Private medical device company founded in 2003 and based in Portland, Oregon, USA Focused

More information

apneabp card(x)plore ABPM-04 Ambulatory Blood Pressure Monitors & Combinations

apneabp card(x)plore ABPM-04 Ambulatory Blood Pressure Monitors & Combinations apneabp card(x)plore ABPM-04 Ambulatory Blood Pressure Monitors & Combinations Meditech Cardiovascular Monitoring Solutions Meditech is one of the worldwide technology leaders in the area of manufacturing

More information

University of Padova, Padua, Italy, and HARVEST Study Group, Italy

University of Padova, Padua, Italy, and HARVEST Study Group, Italy University of Padova, Padua, Italy, and HARVEST Study Group, Italy ISOLATED SYSTOLIC HYPERTENSION IN THE YOUNG DOES NOT IMPLY AN INCREASED RISK OF FUTURE HYPERTENSION NEEDING TREATMENT Mos L, Saladini

More information

Blood Pressure Measurement Does it matter where you do it or how often?

Blood Pressure Measurement Does it matter where you do it or how often? Blood Pressure Measurement Does it matter where you do it or how often? James (Jim) M. Wright Coordinating Editor Cochrane Hypertension Group Conflict of Interest First half evidence based, no conflicts.

More information

Hypertension, Hyperlipidemia and Obesity. Mi-CCSI

Hypertension, Hyperlipidemia and Obesity. Mi-CCSI Hypertension, Hyperlipidemia and Obesity Mi-CCSI Objectives Review the prevalence of hypertension, hyperlipidemia and obesity Correlation of the 3 conditions Discuss why it is important to treat these

More information

ABPM screen 300/400 Risk Assessment

ABPM screen 300/400 Risk Assessment ABPM screen 300/400 Risk Assessment Highlights of custo screen400 ABPM 24 hours Synchronized ABPM and Holter ECG recordings in combination with custo guard 3 72 hours for ABPM recordings alone To our knowledge,

More information

STATE OF THE ART BP ASSESSMENT

STATE OF THE ART BP ASSESSMENT STATE OF THE ART BP ASSESSMENT PROFESSOR MOLECULAR PHARMACOLOGY CONWAY INSTITUE UNIVERSITY COLLEGE DUBLIN CO-CHAIRMAN BLOOD PRESCSURE MANAGEMENT IN LOW RESOURCE SETTINGS CENTRE FOR INTERNATIONAL HUMANITARIAN

More information

Device Equivalence Evaluation Form

Device Equivalence Evaluation Form Comparison of the SAFETY PRONTEX INTEGRA (Nissei DS-B33-03) with the Nissei DSK-1011 Devices Item 9 SAFETY PRONTEX INTEGRA (Nissei DS-B33-03) Nissei DSK-1011 Pictures Display Image Validation ESH IP2010

More information

Preliminary Results of RETREAT

Preliminary Results of RETREAT LINC 2015 Leipzig, Germany, Jan 27-30, 2015 Preliminary Results of RETREAT (Renal Denervation with Ultrasound After Failed Radiofrequency Denervation) Horst Sievert, Jan Philipp Kulow, Stefan Bertog, Predrag

More information

AGING, BLOOD PRESSURE & CARDIOVASCULAR DISEASE EVENT RISK. Michael Smolensky, Ph.D. The University of Texas Austin & Houston

AGING, BLOOD PRESSURE & CARDIOVASCULAR DISEASE EVENT RISK. Michael Smolensky, Ph.D. The University of Texas Austin & Houston AGING, BLOOD PRESSURE & CARDIOVASCULAR DISEASE EVENT RISK Michael Smolensky, Ph.D. The University of Texas Austin & Houston Disclosures Partner: Circadian Ambulatory Diagnostics Consultant: Spot On Sciences

More information

A GUIDE TO OUR NIBP TECHNOLOGY

A GUIDE TO OUR NIBP TECHNOLOGY GE Healthcare THE DINAMAP DIFFERENCE A GUIDE TO OUR NIBP TECHNOLOGY OUR TECHNOLOGICAL ADVANTAGES THE OSCILLOMETRIC METHODOLOGY Oscillometry is the most commonly used means of indirect blood pressure measurement

More information

Chapter-IV. Blood pressure and heart rate variability as function of ovarian cycle in young women

Chapter-IV. Blood pressure and heart rate variability as function of ovarian cycle in young women Blood pressure and heart rate variability as function of ovarian cycle in young women INTRODUCTION In human females, the menstrual cycle begins with the onset of menstrual flow on day 1. The menstrual

More information

MANUAL BLOOD PRESSURE MONITOR BPM 168B Contents Blood Pressure Monitor Intended Use What is blood pressure?

MANUAL BLOOD PRESSURE MONITOR BPM 168B Contents Blood Pressure Monitor Intended Use What is blood pressure? MANUAL BLOOD PRESSURE MONITOR BPM 168B Contents 01... Blood Pressure Monitor Intended Use 02... 1. What is blood pressure? 02... 2. Why is it useful measure blood pressure at home?... A. WHO blood pressure

More information

80 Appendix A. Fig. A.1 Repository of ABPM information containing measurements of the BP

80 Appendix A. Fig. A.1 Repository of ABPM information containing measurements of the BP Appendix A In the first part of the research for developing the initial classifier the data base of 30 patients monitoring during 5 days with 4 readings at day was created for use in the model. The measures

More information

Is Traditional Clinic Blood Pressure Dead?

Is Traditional Clinic Blood Pressure Dead? Royal College of Physicans May 16 th 2017 Is Traditional Clinic Blood Pressure Dead? Professor Bryan Williams MD FRCP FAHA FESC Chair of Medicine UCL Director National Institute for Health Research Biomedical

More information

Special Lecture 10/28/2012

Special Lecture 10/28/2012 Special Lecture 10/28/2012 HYPERTENSION Dr. HN Mayrovitz Special Lecture 10/28/2012 Arterial Blood Pressure (ABP) - Definitions ABP Review Indirect Oscillographic Method Resistance (R), Compliance (C)

More information

Device Equivalence Evaluation Form

Device Equivalence Evaluation Form Device Equivalence Evaluation Form Comparison of the HARTMANN Veroval wrist blood pressure monitor with the AViTA BPM15S Devices HARTMANN Veroval wrist blood pressure monitor AViTA BPM15S Pictures Display

More information

Device Equivalence Evaluation Form

Device Equivalence Evaluation Form Device Equivalence Evaluation Form Comparison of the HARTMANN Veroval upper arm blood pressure monitor with the AViTA BPM63S Devices Pictures HARTMANN Veroval upper arm blood pressure monitor AViTA BPM63S

More information

Treating hypertension in kidney transplant recipients

Treating hypertension in kidney transplant recipients Treating hypertension in kidney transplant recipients Mark Mitsnefes, MD, MS Professor of Pediatrics Director, Clinical Translational Research Center Cincinnati Children s Hospital Medical Center University

More information

Validity study of oscillometric blood pressure measurement devices using an oscillometric waveform simulator

Validity study of oscillometric blood pressure measurement devices using an oscillometric waveform simulator Validity study of oscillometric blood pressure measurement devices using an oscillometric waveform simulator MSc Thesis in Clinical Science and Technology Sara Rose Newell Department of Health Science

More information

Comparison of arbitrary definitions of circadian time periods with those determined by wrist actigraphy in analysis of ABPM data

Comparison of arbitrary definitions of circadian time periods with those determined by wrist actigraphy in analysis of ABPM data Journal of Human Hypertension (1999) 13, 449 453 1999 Stockton Press. All rights reserved 0950-9240/99 $12.00 http://www.stockton-press.co.uk/jhh ORIGINAL ARTICLE Comparison of arbitrary definitions of

More information

가정혈압의활용 CARDIOVASCULAR CENTER. Wook Bum Pyun M.D., Ph.D. HOME BLOOD PRESSURE MONITORING. Ewha Womans University, school of Medicine

가정혈압의활용 CARDIOVASCULAR CENTER. Wook Bum Pyun M.D., Ph.D. HOME BLOOD PRESSURE MONITORING. Ewha Womans University, school of Medicine 가정혈압의활용 HOME BLOOD PRESSURE MONITORING CARDIOVASCULAR CENTER Wook Bum Pyun M.D., Ph.D. pwb423@ewha.ac.kr Ewha Womans University, school of Medicine Non-Invasive Blood Pressure Measurement 5-20% Resistant

More information

Ambulatory Blood Pressure Monitoring Clinical Practice Recommendations

Ambulatory Blood Pressure Monitoring Clinical Practice Recommendations Acta Medica Marisiensis 2016;62(3):350-355 DOI: 10.1515/amma-2016-0038 UPDATE Ambulatory Blood Pressure Monitoring Clinical Practice Recommendations Mako Katalin *, Ureche Corina, Jeremias Zsuzsanna University

More information

White coat and masked hypertension

White coat and masked hypertension White coat and masked hypertension Conflict of interest Support from Spacelabs, Microlife. Honoraria from Novartis, Elpen, Boeringer-Ingelheim, CANA, Lilly, MSD, Sanofi, Menarini, Ciezi, Astra-Zeneca.

More information

Device Equivalence Evaluation Form

Device Equivalence Evaluation Form Comparison of the HARTMANN Veroval BPU22 with the AViTA BPM63S Devices Item 9 HARTMANN Veroval BPU22 AViTA BPM63S Pictures Display Image Validation Equivalence ESH 2010 ESH 2002 BHS AAMI Category Arm Type

More information

Device Equivalence Evaluation Form

Device Equivalence Evaluation Form Comparison of the HARTMANN Veroval BPW22 with the AViTA BPM15S Devices Item 9 HARTMANN Veroval BPW22 AViTA BPM15S Pictures Display Image Validation Equivalence ESH 2010 ESH 2002 BHS AAMI Category Wrist

More information

SYNOPSIS. Publications No publications at the time of writing this report.

SYNOPSIS. Publications No publications at the time of writing this report. Drug product: TOPROL-XL Drug substance(s): Metoprolol succinate Study code: D4020C00033 (307A) Date: 8 February 2006 SYNOPSIS Dose Ranging, Safety and Tolerability of TOPROL-XL (metoprolol succinate) Extended-release

More information

Raw BP and Eight Hemodynamic Measurements Displayed in Real Time

Raw BP and Eight Hemodynamic Measurements Displayed in Real Time APPLICATION NOTE 42 Aero Camino, Goleta, CA 93117 Tel (805) 685-0066 Fax (805) 685-0067 info@biopac.com www.biopac.com Updated 01.11.2016 Application Note 115: Hemodynamic Measurements Raw BP and Eight

More information

& Wilkins. a Division of Cardiology, Schulich Heart Centre, b Institute for Clinical and

& Wilkins. a Division of Cardiology, Schulich Heart Centre, b Institute for Clinical and Original article 333 Optimum frequency of office blood pressure measurement using an automated sphygmomanometer Martin G. Myers a, Miguel Valdivieso a and Alexander Kiss b,c Objective To determine the

More information

ANTIHYPERTENSIVE DRUG THERAPY IN CONSIDERATION OF CIRCADIAN BLOOD PRESSURE VARIATION*

ANTIHYPERTENSIVE DRUG THERAPY IN CONSIDERATION OF CIRCADIAN BLOOD PRESSURE VARIATION* Progress in Clinical Medicine 1 ANTIHYPERTENSIVE DRUG THERAPY IN CONSIDERATION OF CIRCADIAN BLOOD PRESSURE VARIATION* Keishi ABE** Asian Med. J. 44(2): 83 90, 2001 Abstract: J-MUBA was a large-scale clinical

More information

Digital Blood Pressure Monitor. Model UA-767 BT

Digital Blood Pressure Monitor. Model UA-767 BT Digital Blood Pressure Monitor Model UA-767 BT Instruction Manual WM+PD4001054B 13 Contents Dear Customers... 2 Preliminary Remarks... 2 Precautions... 2 Parts Identification... 3 Symbols... 4 Using The

More information

Adherence to Hypertension Visit Protocol Description: % of patients with HTN who are being monitored through follow up visits according to guidelines, based on "days since last BP", which looks back from

More information

Comparison of the Microlife A2 Basic (BP3GQ1-3P) with the Microlife BP3BT0-A and Microlife BP A100 Plus

Comparison of the Microlife A2 Basic (BP3GQ1-3P) with the Microlife BP3BT0-A and Microlife BP A100 Plus Comparison of the Microlife A2 Basic (BP3GQ1-3P) with the Microlife BP3BT0-A and Microlife BP A100 Plus Devices Microlife A2 Basic (BP3GQ1-3P) 9 BP3BT0-A 9 Microlife BP A100 Plus 9 Image 10 10 10 Validation

More information

Importance of Ambulatory Blood Pressure Monitoring in Adolescents

Importance of Ambulatory Blood Pressure Monitoring in Adolescents Importance of Ambulatory Blood Pressure Monitoring in Adolescents Josep Redon, MD, PhD, FAHA Internal Medicine Hospital Clinico Universitario de Valencia University of Valencia CIBERObn Instituto de Salud

More information

Monitor Instructions for Models: CHB-R6 CHB-UV6

Monitor Instructions for Models: CHB-R6 CHB-UV6 Monitor Instructions for Models: CHB-R6 CHB-UV6 Power supply: output DC 9v/ 1000mA transformer adaptor TABLE OF CONTENTS Function Buttons ----------------------------------------------------------------------------

More information

Masked Hypertension and Aortic Coarctation: Impact on Ventricular Function and Morphology

Masked Hypertension and Aortic Coarctation: Impact on Ventricular Function and Morphology Masked Hypertension and Aortic Coarctation: Impact on Ventricular Function and Morphology Giovanni Di Salvo MD, PhD, MMSc, FESC BACKGROUND MASKED HYPERTENSION Masked hypertension (MH) consists of an elevated

More information

Normal Ambulatory Blood Pressure: A Clinical-Practice- Based Analysis of Recent American Heart Association Recommendations

Normal Ambulatory Blood Pressure: A Clinical-Practice- Based Analysis of Recent American Heart Association Recommendations The American Journal of Medicine (2006) 119, 69.e13-69.e18 CLINICAL RESEARCH STUDY Normal Ambulatory Blood Pressure: A Clinical-Practice- Based Analysis of Recent American Heart Association Recommendations

More information

Evaluation and Management of Hypertension in Women. Vesna D. Garovic, M.D. Moscow, Russia, December 2016

Evaluation and Management of Hypertension in Women. Vesna D. Garovic, M.D. Moscow, Russia, December 2016 Evaluation and Management of Hypertension in Women Vesna D. Garovic, M.D. Moscow, Russia, December 2016 2016 MFMER 3508058-1 Women are not small men There is nothing as powerful as an idea whose time has

More information

Mi-CCSI welcomes you to the 2 nd in our 4 part Basics of Disease Management Webinar Series

Mi-CCSI welcomes you to the 2 nd in our 4 part Basics of Disease Management Webinar Series Our speaker today is: Susan Vos, BSN, RN, CCM Mi-CCSI welcomes you to the 2 nd in our 4 part Basics of Disease Management Webinar Series We will be starting shortly A few housekeeping items: We will be

More information

HYPERTENSION: ARE WE GOING TOO LOW?

HYPERTENSION: ARE WE GOING TOO LOW? HYPERTENSION: ARE WE GOING TOO LOW? George L. Bakris, M.D.,F.A.S.N.,F.A.S.H., F.A.H.A. Professor of Medicine Director, ASH Comprehensive Hypertension Center University of Chicago Medicine Chicago, IL USA

More information

Stephen G. Worthley 1, Gerard T. Wilkins 2, Mark W. Webster 3,Joseph K. Montarello 1, Paul T. Antonis 4, Robert J. Whitbourn 5, Roderic J.

Stephen G. Worthley 1, Gerard T. Wilkins 2, Mark W. Webster 3,Joseph K. Montarello 1, Paul T. Antonis 4, Robert J. Whitbourn 5, Roderic J. Six Month Results of First-in-Human Sympathetic Renal Artery Denervation Using a Next Generation Multi-Electrode Renal Artery Denervation System in Patients with Drug-Resistant Hypertension Stephen G.

More information

Catheter-Based Renal Sympathetic Denervation in the Management of Resistant Hypertension

Catheter-Based Renal Sympathetic Denervation in the Management of Resistant Hypertension Catheter-Based Renal Sympathetic Denervation in the Management of Resistant Hypertension Henry Krum, Markus Schlaich, Paul Sobotka, Rob Whitbourn, Jerzy Sadowski, Krzysztof Bartus, Boguslaw Kapelak, Horst

More information

Hypertension Guidelines 2017

Hypertension Guidelines 2017 Hypertension Guidelines 2017 (American College of Cardiology and the American Heart Association) In 1977, the 1st comprehensive guideline for detection, evaluation, and management of high BP was published,

More information

Determination of Blood Pressure and Hemodynamics from Oscillometric Waveforms

Determination of Blood Pressure and Hemodynamics from Oscillometric Waveforms Determination of Blood Pressure and Hemodynamics from Oscillometric Waveforms J. Jilek*, M. Stork** *Carditech, Culver City, California, USA **Department of Applied Electronics and Telecommunications University

More information

INCREASED PULSE PRESSURE AND SYSTOLIC x HEART RATE DOUBLE PRODUCT AND CARDIOVASCULAR AUTONOMIC NEUROPATHY IN TYPE 2 DIABETIC PATIENTS

INCREASED PULSE PRESSURE AND SYSTOLIC x HEART RATE DOUBLE PRODUCT AND CARDIOVASCULAR AUTONOMIC NEUROPATHY IN TYPE 2 DIABETIC PATIENTS INCREASED PULSE PRESSURE AND SYSTOLIC x HEART RATE DOUBLE PRODUCT AND CARDIOVASCULAR AUTONOMIC NEUROPATHY IN TYPE 2 DIABETIC PATIENTS A.J. Scheen, J.C. Philips, M. Marchand Division of Diabetes, Nutrition

More information

Impedance Cardiography (ICG) Application of ICG for Hypertension Management

Impedance Cardiography (ICG) Application of ICG for Hypertension Management Application of ICG for Hypertension Management 1mA @ 100 khz Impedance Cardiography (ICG) Non-invasive Beat-to-beat Hemodynamic Monitoring Diastole Systole Aortic valve is closed No blood flow in the aorta

More information

Comparison of the Microlife A6 PC (BP3GU1-8Y) with the Microlife BP3BT0-A and Microlife BP A100 Plus

Comparison of the Microlife A6 PC (BP3GU1-8Y) with the Microlife BP3BT0-A and Microlife BP A100 Plus Comparison of the Microlife A6 PC (BP3GU1-8Y) with the Microlife BP3BT0-A and Microlife BP A100 Plus Devices Microlife A6 PC (BP3GU1-8Y) 9 BP3BT0-A 9 Microlife BP A100 Plus 9 Image 10 10 10 Validation

More information

Time of day for exercise on blood pressure reduction in dipping and nondipping hypertension

Time of day for exercise on blood pressure reduction in dipping and nondipping hypertension (2005) 19, 597 605 & 2005 Nature Publishing Group All rights reserved 0950-9240/05 $30.00 www.nature.com/jhh ORIGINAL ARTICLE on blood pressure reduction in dipping and nondipping hypertension S Park,

More information

BLOOD PRESSURE MEASUREMENT HOME BASED OR OFFICE BP MONITORING WHICH, HOW AND WHEN?

BLOOD PRESSURE MEASUREMENT HOME BASED OR OFFICE BP MONITORING WHICH, HOW AND WHEN? BLOOD PRESSURE MEASUREMENT HOME BASED OR OFFICE BP MONITORING WHICH, HOW AND WHEN? DECLARATION OF INTEREST Medical Director and Chairman, Advisory Board dabl Ltd., Dublin, Ireland. BLOOD PRESSURE MEASUREMENT

More information

VITAL SIGNS MONITORING. RVS-100/200 ri-vital. Vital Signs Patient Monitors

VITAL SIGNS MONITORING. RVS-100/200 ri-vital. Vital Signs Patient Monitors VITAL SIGNS MONITORING RVS-100/200 ri-vital Vital Signs Patient Monitors RVS-100 ADVANCED VITAL SIGNS MONITOR The RVS-100 is an advanced vital signs monitor which offers pulse oximetry, blood pressure

More information

Biomedical Instrumentation E. Blood Pressure

Biomedical Instrumentation E. Blood Pressure Biomedical Instrumentation E. Blood Pressure Dr Gari Clifford Adapted from slides by Prof. Lionel Tarassenko Blood pressure Blood is pumped around the body by the heart. It makes its way around the body

More information

Determination of left ventricular stroke volume from the arterial pressure wave

Determination of left ventricular stroke volume from the arterial pressure wave Integrative Human Cardiovascular Control The Panum Institute/ Rigshospitalet, University of Copenhagen May 2018 Determination of left ventricular stroke volume from the arterial pressure wave Jo(Han)nes

More information

Special Lecture 11/08/2013. Hypertension Dr. HN Mayrovitz

Special Lecture 11/08/2013. Hypertension Dr. HN Mayrovitz Special Lecture 11/08/2013 Hypertension Dr. HN Mayrovitz Arterial Blood Pressure (ABP) Major Factors Summarized Sympathetic Hormones Arteriole MAP ~ Q x TPR + f (V / C) SV x HR Renal SBP Hypertension =

More information

Device Equivalence Evaluation Form

Device Equivalence Evaluation Form Comparison of the Omron M6 Comfort IT (HEM-7322U-E) with the Omron M6 Comfort (HEM-7321-E) Devices Omron M6 Comfort IT (HEM-7322U-E) Omron M6 Comfort (HEM-7321-E) Pictures Display Validation ESH 2010 Device

More information

New Hypertension Guideline Recommendations for Adults July 7, :45-9:30am

New Hypertension Guideline Recommendations for Adults July 7, :45-9:30am Advances in Cardiovascular Disease 30 th Annual Convention and Reunion UERM-CMAA, Inc. Annual Convention and Scientific Meeting July 5-8, 2018 New Hypertension Guideline Recommendations for Adults July

More information

BackBeat Cardiac Neuromodulation Therapy (CNT) for Immediate, Substantial and Sustained Lowering of Blood Pressure. Daniel Burkhoff MD PhD

BackBeat Cardiac Neuromodulation Therapy (CNT) for Immediate, Substantial and Sustained Lowering of Blood Pressure. Daniel Burkhoff MD PhD BackBeat Cardiac Neuromodulation Therapy (CNT) for Immediate, Substantial and Sustained Lowering of Blood Pressure Daniel Burkhoff MD PhD Director Heart Failure, Hemodynamics and Mechanical Support Research

More information

Recent Advances in Ambulatory Blood Pressure

Recent Advances in Ambulatory Blood Pressure C H A P T E R 150 Recent Advances in Ambulatory Blood Pressure Ashok L Kirpalani, Dilip A Kirpalani The understanding of Hypertension has evolved over the last century. A single mercury manometer reading

More information

Vital Signs. (866)

Vital Signs.  (866) Vital Signs Obesity, diabetes and sedentary lifestyles may greatly influence a client s abilities during testing procedures in your Occupational Health Services. There has been an increase prevalence in

More information

Technique. Technique. Technique. Monitoring 1. Local anesthetic? Aseptic technique Hyper-extend (if radial)

Technique. Technique. Technique. Monitoring 1. Local anesthetic? Aseptic technique Hyper-extend (if radial) Critical Care Monitoring Hemodynamic Monitoring Arterial Blood Pressure Cannulate artery Uses 2 Technique Sites Locate artery, prep 3 1 Technique Local anesthetic? Aseptic technique Hyper-extend (if radial)

More information

Dr Diana R Holdright. MD, FRCP, FESC, FACC, MBBS, DA, BSc. Consultant Cardiologist HYPERTENSION.

Dr Diana R Holdright. MD, FRCP, FESC, FACC, MBBS, DA, BSc. Consultant Cardiologist HYPERTENSION. Dr Diana R Holdright MD, FRCP, FESC, FACC, MBBS, DA, BSc. Consultant Cardiologist HYPERTENSION www.drholdright.co.uk Blood pressure is the pressure exerted on the walls of the arteries when the heart pumps;

More information

Managing anti-hypertensive treatment with SphygmoCor XCEL

Managing anti-hypertensive treatment with SphygmoCor XCEL Managing anti-hypertensive treatment with SphygmoCor XCEL Measurement of Central aortic BP may provide valuable information on antihypertensive drug action that is not apparent with assessment of Brachial

More information

Blunt Traumatic Aortic Rupture and the Aortic Response to High Speed Impact MARK COHEN AND LYES KADEM

Blunt Traumatic Aortic Rupture and the Aortic Response to High Speed Impact MARK COHEN AND LYES KADEM Blunt Traumatic Aortic Rupture and the Aortic Response to High Speed Impact MARK COHEN AND LYES KADEM Blunt Traumatic Aortic Rupture (BTAR) In North America, approximately 19% of all auto accident fatalities

More information

Reference Values and Simplified Methods for Interpretation of Blood Pressure in Children and Adolescents

Reference Values and Simplified Methods for Interpretation of Blood Pressure in Children and Adolescents Reference Values and Simplified Methods for Interpretation of Blood Pressure in Children and Adolescents Simonetti G.D. Istituto Pediatrico della Svizzera Italiana Ente Ospedaliero Cantonale e Università

More information

BP Pump 2. Non-Invasive Blood Pressure Simulator and Tester. Technical Data. Key features

BP Pump 2. Non-Invasive Blood Pressure Simulator and Tester. Technical Data. Key features BP Pump 2 Non-Invasive Blood Pressure Simulator and Tester Technical Data The BP Pump 2 provides dynamic blood-pressure simulations for testing adult and neonatal noninvasive blood pressure monitors, including

More information

Todd S. Perlstein, MD FIFTH ANNUAL SYMPOSIUM

Todd S. Perlstein, MD FIFTH ANNUAL SYMPOSIUM Todd S. Perlstein, MD FIFTH ANNUAL SYMPOSIUM Faculty Disclosure I have no financial interest to disclose No off-label use of medications will be discussed FIFTH ANNUAL SYMPOSIUM Recognize changes between

More information

Hypertension and the SPRINT Trial: Is Lower Better

Hypertension and the SPRINT Trial: Is Lower Better Hypertension and the SPRINT Trial: Is Lower Better 8th Annual Orange County Symposium on Cardiovascular Disease Prevention Saturday, October 8, 2016 Keith C. Norris, MD, PhD, FASN Professor of Medicine,

More information

The Evolution To Treatment Of Hypertension With Advanced Formulation

The Evolution To Treatment Of Hypertension With Advanced Formulation The Evolution To Treatment Of Hypertension With Advanced Formulation Dr. Donald Ang MBChB (UK) FRCP (Edin) MD (UK) CCST Cardiology (UK) FESC (Europe) Consultant Cardiologist Island Hospital Penang High

More information

NIH Public Access Author Manuscript JAMA Intern Med. Author manuscript; available in PMC 2015 August 01.

NIH Public Access Author Manuscript JAMA Intern Med. Author manuscript; available in PMC 2015 August 01. NIH Public Access Author Manuscript Published in final edited form as: JAMA Intern Med. 2014 August ; 174(8): 1397 1400. doi:10.1001/jamainternmed.2014.2492. Prevalence and Characteristics of Systolic

More information

Egyptian Hypertension Guidelines

Egyptian Hypertension Guidelines Egyptian Hypertension Guidelines 2014 Egyptian Hypertension Guidelines Dalia R. ElRemissy, MD Lecturer of Cardiovascular Medicine Cairo University Why Egyptian Guidelines? Guidelines developed for rich

More information

Impedance Cardiography (ICG) Method, Technology and Validity

Impedance Cardiography (ICG) Method, Technology and Validity Method, Technology and Validity Hemodynamic Basics Cardiovascular System Cardiac Output (CO) Mean arterial pressure (MAP) Variable resistance (SVR) Aortic valve Left ventricle Elastic arteries / Aorta

More information

Vital Signs. Vital Signs. Pulse. Temperature. Respiration. Blood Pressure

Vital Signs. Vital Signs. Pulse. Temperature. Respiration. Blood Pressure Vital Signs Jarvis, Chapter 9 Vital Signs Classic Vital Signs TPR/BP Temperature Pulse Respirations Blood Pressure Additional Vital Signs Height Weight BMI (Kg/m2) or (702Xlbs/in2) Supine, orthostatic

More information

The Association of Pediatric Obesity with Nocturnal Non-Dipping on. 24-Hour Ambulatory Blood Pressure Monitoring. Ian Macumber.

The Association of Pediatric Obesity with Nocturnal Non-Dipping on. 24-Hour Ambulatory Blood Pressure Monitoring. Ian Macumber. The Association of Pediatric Obesity with Nocturnal Non-Dipping on 24-Hour Ambulatory Blood Pressure Monitoring Ian Macumber A thesis submitted in partial fulfillment of the requirements for the degree

More information

AFFORDABLE TECHNOLOGY

AFFORDABLE TECHNOLOGY World Health Organization AFFORDABLE TECHNOLOGY BLOOD PRESSURE MEASURING DEVICES FOR LOW RESOURCE SETTINGS CARDIOVASCULAR DISEASES Blood Pressure Measurement in Low Resource Settings Annex 1: Blood Pressure

More information

MASSACHUSETTS INSTITUTE OF TECHNOLOGY

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Harvard-MIT Division of Health Sciences and Technology HST.542J: Quantitative Physiology: Organ Transport Systems Instructors: Roger Mark and Jose Venegas MASSACHUSETTS INSTITUTE OF TECHNOLOGY Departments

More information

Theoretical and practical questions in the evaluation of arterial function Miklós Illyés MD. Ph.D.

Theoretical and practical questions in the evaluation of arterial function Miklós Illyés MD. Ph.D. Theoretical and practical questions in the evaluation of arterial function Miklós Illyés MD. Ph.D. TensioMed Arterial Stiffness Centre, Budapest Heart Institute, Faculty of Medicine, University of Pécs

More information

Blood Pressure Acre Surgery Diviash Thakrar

Blood Pressure Acre Surgery Diviash Thakrar Blood Pressure Acre Surgery Diviash Thakrar Why Are We Doing This? 1. Improve education for patients within the practice 2. Allow us use this for general health promotion Raise money for charity 3. Raise

More information

Copyright Lippincott Williams & Wilkins. Unauthorized reproduction of this article is prohibited.

Copyright Lippincott Williams & Wilkins. Unauthorized reproduction of this article is prohibited. Devices and technology 57 Comparison of wrist-type and arm-type 24-h blood pressure monitoring devices for ambulatory use Takahiro Komori a, Kazuo Eguchi a, Satoshi Hoshide a, Bryan Williams b and Kazuomi

More information

Update on HTN and ABPM. Raj Padwal Division of General Internal Medicine University of Alberta

Update on HTN and ABPM. Raj Padwal Division of General Internal Medicine University of Alberta Update on HTN and ABPM Raj Padwal Division of General Internal Medicine University of Alberta Disclosures Funding: CIHR, AIHS, HSF, UHF Research Collaboration: Novo Nordisk, CVRx Consulting: Vivus, Medtronic

More information

Chapter-V. Summary, Conclusions and Recommendations

Chapter-V. Summary, Conclusions and Recommendations Summary, Conclusions and Recommendations INTRODUCTION The work included in this thesis entitled, Circadian heart rate and blood pressure variability in apparently healthy subjects using ABPM has been divided

More information

Heart Rate, Blood Pressure, and Exercise. Evaluation copy

Heart Rate, Blood Pressure, and Exercise. Evaluation copy Heart Rate, Blood Pressure, and Exercise Computer 11 The adaptability of the heart can be observed during exercise, when the metabolic activity of skeletal muscles increases. The cardiovascular system,

More information

Quality ID #122: Adult Kidney Disease: Blood Pressure Management National Quality Strategy Domain: Effective Clinical Care

Quality ID #122: Adult Kidney Disease: Blood Pressure Management National Quality Strategy Domain: Effective Clinical Care Quality ID #122: Adult Kidney Disease: Blood Pressure Management National Quality Strategy Domain: Effective Clinical Care 2018 OPTIONS FOR INDIVIDUAL MEASURES: REGISTRY ONLY MEASURE TYPE: Intermediate

More information

Adolescent Hypertension Roles of obesity and hyperuricemia. Daniel Landau, MD Pediatrics, Soroka University Medical Center

Adolescent Hypertension Roles of obesity and hyperuricemia. Daniel Landau, MD Pediatrics, Soroka University Medical Center Adolescent Hypertension Roles of obesity and hyperuricemia Daniel Landau, MD Pediatrics, Soroka University Medical Center Blood Pressure Tables BP standards based on sex, age, and height provide a precise

More information

13. Blood Pressure. Millie Grim Geek Rea New Zealand

13. Blood Pressure. Millie Grim Geek Rea New Zealand 13. Blood Pressure Millie Grim Geek Rea New Zealand 1 Presentation Outline Explanation of Blood Pressure (BP) Methods of Measurement Inherent Variation exploration of the physiological variables Effect

More information

Therefore MAP=CO x TPR = HR x SV x TPR

Therefore MAP=CO x TPR = HR x SV x TPR Regulation of MAP Flow = pressure gradient resistance CO = MAP TPR Therefore MAP=CO x TPR = HR x SV x TPR TPR is the total peripheral resistance: this is the combined resistance of all blood vessels (remember

More information

Crucial Signs כל הזכויות שמורות למד"א מרחב ירושלים

Crucial Signs כל הזכויות שמורות למדא מרחב ירושלים Crucial Signs Dan Drory, MDA Paramedic and Instructor, 2011 What are Signs? Sign Objective, measurable Symptom Subjective, evaluated by the patient ( Chest Pain, Difficulties Breathing, Headache ) Signs

More information

Arm position and blood pressure: a risk factor for hypertension?

Arm position and blood pressure: a risk factor for hypertension? (3) 17, 389 395 & 3 Nature Publishing Group All rights reserved 09-9240/03 $25.00 www.nature.com/jhh ORIGINAL ARTICLE Arm position and blood pressure: a risk factor for hypertension? A Mourad, S Carney,

More information

GETTING THE NUMBERS RIGHT: ACCURATE MEASUREMENT OF BLOOD PRESSURE

GETTING THE NUMBERS RIGHT: ACCURATE MEASUREMENT OF BLOOD PRESSURE GETTING THE NUMBERS RIGHT: ACCURATE MEASUREMENT OF BLOOD PRESSURE Pamela B. Morris, MD, FACC, FAHA, FASPC, FNLA Professor Medicine and Cardiovascular Diseases Director, Seinsheimer Cardiovascular Health

More information

Hypertension: What s new since JNC 7. Harold M. Szerlip, MD, FACP, FCCP, FASN, FNKF

Hypertension: What s new since JNC 7. Harold M. Szerlip, MD, FACP, FCCP, FASN, FNKF Hypertension: What s new since JNC 7 Harold M. Szerlip, MD, FACP, FCCP, FASN, FNKF Disclosures Spectral Diagnostics Site investigator Eli Lilly Site investigator ACP IM ITE writing committee NBME Step

More information

Heart Rate and Blood Pressure as Vital Signs

Heart Rate and Blood Pressure as Vital Signs Heart Rate and Blood Pressure as Vital Signs Computer 10 Since the earliest days of medicine heart rate has been recognized as a vital sign an indicator of health, disease, excitement, and stress. Medical

More information

4/4/17 HYPERTENSION TARGETS: WHAT DO WE DO NOW? SET THE STAGE BP IN CLINICAL TRIALS?

4/4/17 HYPERTENSION TARGETS: WHAT DO WE DO NOW? SET THE STAGE BP IN CLINICAL TRIALS? HYPERTENSION TARGETS: WHAT DO WE DO NOW? MICHAEL LEFEVRE, MD, MSPH PROFESSOR AND VICE CHAIR DEPARTMENT OF FAMILY AND COMMUNITY MEDICINE UNIVERSITY OF MISSOURI 4/4/17 DISCLOSURE: MEMBER OF THE JNC 8 PANEL

More information

Hypertension Management Controversies in the Elderly Patient

Hypertension Management Controversies in the Elderly Patient Hypertension Management Controversies in the Elderly Patient Juan Bowen, MD Geriatric Update for the Primary Care Provider November 17, 2016 2016 MFMER slide-1 Disclosure No financial relationships No

More information

Importance Of Taking Manual Blood Pressure In Both Arms

Importance Of Taking Manual Blood Pressure In Both Arms Importance Of Taking Manual Blood Pressure In Both Arms Its importance to health is now well-recognised, in that high blood pressure can lead to Have a look at our slide show on how to take a blood pressure

More information