1 Published Online August 21, 2013 Myocardial perfusion scintigraphy using rubidium-82 positron emission tomography Parthiban Arumugam *, Deborah Tout, and Christine Tonge Nuclear Medicine Centre, Central Manchester NHS Foundation Trust, Manchester, UK Introduction: Myocardial perfusion scintigraphy (MPS) is an established noninvasive technique for the diagnosis and management of patients with suspected or known coronary artery disease. Because of the wealth of prognostic data, MPS single photon emission computed tomography (SPECT) is the most commonly used functional test to detect inducible ischaemia. However, the increasing availability of positron emission tomography (PET) scanners for oncology along with the introduction of the generator-produced PET tracer rubidium-82 ( 82 Rb) has helped the growth of MPS PET. Sources of data: Relevant review articles, primary literature and clinical guidelines identified through medical literature search engines. Areas of agreement: PET offers advantages over SPECT, including increased patient throughput because of rapid scanning protocols, reduced radiation exposure to patients and the ability to quantify tracer distribution accurately and hence measure myocardial perfusion in millilitre per gram per minute and hence myocardial perfusion reserve (MPR). Areas of controversy: Although PET has advantages over SPECT, there are no largescale prognostic or cost-effectiveness data to support it use as the primary MPS technique. Growing points: A wider use of absolute measurements of perfusion has the potential to improve diagnostic accuracy and to add prognostic value over relative assessment of myocardial perfusion. Areas timely for developing research: Assessment of absolute myocardial perfusion may provide insight into the effects of traditional risk factors on perfusion reserve and the impact of risk factor modifications on progression of coronary artery disease. *Correspondence address. Nuclear Medicine Centre, Manchester Royal Infirmary, Oxford Road, Manchester M13 9WL, UK. parthiban. arumugam@cmft.nhs.uk Keywords: PET perfusion/myocardial blood flow/myocardial perfusion scintigraphy Accepted: July 24, 2013 British Medical Bulletin 2013; 107: DOI: /bmb/ldt026 & The Author Published by Oxford University Press. All rights reserved. For permissions, please journals.permissions@oup.com

2 P. Arumugam et al. Introduction As the evidence accumulates for the benefits of managing coronary artery disease (CAD) based upon its functional significance, there has been a shift from an approach based upon the coronary anatomy. 1,2 Although fractional flow reserve (FFR) provides an invasive assessment of coronary function, non-invasive imaging in the form of MPS, stress echocardiography and cardiac magnetic resonance (CMR) can provide similar information. Myocardial perfusion scintigraphy (MPS) single photon emission computed tomography (SPECT) is the most commonly used technique and there is extensive and robust data on its diagnostic accuracy, prognostic power and its cost-effectiveness. 3 However, the limitations of SPECT include image artefacts, especially due to soft tissue attenuation, and the lack of quantification. The images are displayed using a colour scale that shows the myocardium with highest (but not necessarily normal) uptake at the top of the scale and the rest of the myocardium scaled down accordingly. The display is therefore relative to the region with highest tracer uptake and it is possible to underestimate the severity of ischaemia if all areas have abnormal perfusion reserve. 4 Although there have been significant developments in SPECT technology including attenuation correction, resolution recovery and dynamic solid state cameras, positron emission tomography (PET) can provide all of this and more. Almost all oncology PET cameras are combined with high-resolution X-ray computed tomography (CT) and, for the heart, these can provide multimodality images combining anatomical and functional information. This review will however focus on the functional component using 82 Rb. Imaging principles of MPS PET Tracer characteristics Cardiac PET requires the intravenous administration of a radionuclide tracer, which is taken up by the myocardium. The PET tracers in clinical use are either produced in a cyclotron or locally in a generator. A cyclotron is a particle accelerator capable of rapidly accelerating charged particles, which can be made to bombard a target to produce positron-emitting isotopes. An on-site cyclotron is not available in the majority of PET centres because of its cost and complexity and this limits the use of the very short half-life positron-emitting isotopes. Generator-produced isotopes are simpler and more convenient as the generator can provide continuous on-site production for its lifetime, which will depend on the half-life of the parent isotope. The characteristics of the most commonly used cardiac 88 British Medical Bulletin 2013;107

3 MPS using rubidium-82 PET PET tracers are shown in Table 1. Tracer delivery is proportional to blood flow, but myocardial uptake depends also on its extraction from the blood. The most physiological tracer is oxygen-15 ( 15 O) water, which is freely diffusible and has a first pass extraction of 100% with rapid equilibrium between the vascular and tissue compartments. Accurate measurements of myocardial perfusion can be made but high-quality images of myocardial perfusion are not possible. Instead mathematical models must be used to produce parametric images of perfusion but these are often noisy and of poor quality. 5 Nitrogen-13 ( 13 N) ammonia enters the myocyte by passive diffusion or active transport with a first pass extraction of 80%, and it is rapidly metabolized to glutamine and retained in the myocyte. Because of its short half-life its use is restricted to centres with a cyclotron. It provides images of relative perfusion and cardiac function similar to SPECT and measurements of myocardial perfusion are well validated Rb is produced from an 82 Sr 82 Rb generator, which has a clinical life of 4 6 weeks. The 82 Rb is administered by remote intravenous infusion and the generator can be eluted with >90% yield every 10 min. 82 Rb is a potassium analogue and it crosses the capillary membrane rapidly, partly using the sodium potassium exchange transporter. It has a first pass extraction of 65%, which is higher than the 99m Tc SPECT tracers but similar to thallium-201. At high values of perfusion the extraction becomes rate limiting and the linearity of uptake falls. 6 The half-life of 82 Rb of 75 s allows rapid serial imaging at rest and during stress and it also leads to a lower radiation exposure for the patient than with the SPECT tracers. A fluorine-18 ( 18 F) labeled perfusion tracer, flurpiridaz, is undergoing phase 3 clinical trials. It is a mitochondrial agent that has high myocardial extraction over a wide range of perfusion and good tracer retention without significant redistribution. 7 It does not require a generator or an Table 1 The characteristics of the most commonly used cardiac PET tracers 15 O-Water 13 N-Ammonia 82 Rb-Chloride Half-life (min) Production Cyclotron Cyclotron Generator Resolution (RMS β+ range in water) Very good (1.02 mm) Excellent (0.57 mm) Good (2.60 mm) Uptake Free diffusion Free diffusion and metabolic trapping (Na+/K+ ATPase) Metabolic trapping (Na+/K+ ATPase) First pass extraction fraction 100% 80% 65% Exercise stress No Yes No Relationship with blood flow Linear Non-linear Non-linear Perfusion images? No Yes Yes Absolute measurement of perfusion? Yes Yes yes British Medical Bulletin 2013;107 89

4 P. Arumugam et al. on-site cyclotron because the 110 min half-life of 18 F means that it can be produced remotely. If the tracer is approved for clinical use and is affordable, the quality of its images and its versatility are likely to lead to a more widespread use of MPS PET. Physical characteristics Lead collimators are required in SPECT to form images only from photons that travel perpendicularly to the detector face. This leads to relatively low sensitivity but the PET technique does not require a collimator and has higher sensitivity, typically by two to three orders of magnitude (Fig. 1). The spatial resolution of PET is also superior to SPECT, although resolution recovery can improve the resolution of SPECT. The typical resolution of PET is 5 7 mm compared with mm for SPECT. The finite distance travelled by an emitted positron before annihilation to produce two 511 kev photons travelling in opposite directions can limit PET resolution, and this is highest with 82 Rb (see Table 1). Attenuation (absorption) of photons occurs as they traverse the patient. The amount of attenuation depends on the distance and the density of tissue involved. Scatter occurs when a photon is deflected from its original course by an object within its path and the photon is detected in a different part of the detector from its origin. Both attenuation and scatter artefacts can degrade image quality and lead to erroneous estimation of tracer distribution. This is a particular problem in obese patients. Both attenuation correction (AC) and scatter correction (SC) are much more accurate for PET than for SPECT, and attenuation artefact is less commonly encountered. Therefore this also gives PET the potential for absolute quantitation of tissue tracer concentration and hence kinetic modelling for the measurement of absolute myocardial perfusion. Fig. 1 Effect of collimation on detector sensitivity. Absolute perfusion measurement PET is the most accurate non-invasive method of measuring myocardial perfusion and perfusion reserve (MPR: the ratio of stress to rest 90 British Medical Bulletin 2013;107

5 MPS using rubidium-82 PET blood flow). 5 FFR and myocardial perfusion and perfusion reserve measurements probably represent different pathophysiological processes the former is influenced by epicardial disease processes, both focal and diffuse and the latter in addition is affected by changes in the microcirculation. A detailed discussion of the difference between FFR and MPR is beyond the scope of this article and further reading of the article by Lance Gould is recommended O water is the ideal perfusion tracer because of the linear relationship between perfusion and tracer uptake but, because it does not produce images, 13 N-ammonia is a more practical standard. Both require an on-site cyclotron and so the generator produced 82 Rb is now more commonly used. 9 Various software applications are available for the quantification of myocardial perfusion using 82 Rb PET and the results compare favorably with other validated methods The normal ranges for stress and rest perfusion vary according to the technique used and resting perfusion is dependent upon heart rate, systolic blood pressure and vascular resistance. The values for 82 Rb tend to be lower than that for 13 N-ammonia and 15 O-water. Imaging protocol The protocol used in our centre for adenosine 82 Rb PET is shown in Fig. 2. The patient is positioned with arms above the head and is inside the scanner for the duration of the protocol, 30 min. Staff are outside the scan room and the patient is monitored remotely using CCTV, two-way intercom, electrocardiogram (ECG) and blood pressure monitoring. A CT scout view is acquired to localize the left ventricle, followed by a low-dose CT for AC of the emission data (CTAC). Two emission images are acquired, typically rest followed by stress, with intravenous 82 Rb infusion from the generator using a semi-automated process. Exercise is difficult within the scanner (Fig. 3) and so stress is exclusively pharmacological using adenosine or regadenoson. The procedure is short compared with 4 6 h for a 1-day stress/rest 99m Tc protocol or two separate visits of 90 min for a 2-day 99m Tc protocol. There are therefore significant benefits for patient time, and staff equipment contact time is also reduced. Fig. 2 Routine clinical imaging protocol for 82 Rb cardiac PET. British Medical Bulletin 2013;107 91

6 P. Arumugam et al. Fig. 3 Patient positioning during the stress test and PET imaging. Image interpretation PET perfusion images from 13 N-ammonia and 82 Rb are displayed in the same way as SPECT and hence reflect relative tracer distribution. However, the stress images are acquired during stress and so the information on left ventricle (LV) function from the ECG-gated acquisition reflects peak stress rather than the post-stress state for SPECT. Image interpretation is similar to SPECT, although the higher resolution and attenuation correction mean that normal appearances differ. Normal values for myocardial perfusion depend upon the software used but normal resting perfusion range is ml/g/min with a normal vasodilator perfusion reserve >2. 13 Clinical application Comparison with SPECT Both SPECT and PET images show relative tracer uptake but PET has better resolution, higher counts and more accurate attenuation and scatter correction. Bateman et al. 14 compared 82 Rb PET with 99m Tc-MIBI SPECT in patients who were well matched for physical and clinical variables. Image quality was better with PET than SPECT and they were 92 British Medical Bulletin 2013;107

7 MPS using rubidium-82 PET interpreted with greater certainty as either normal or abnormal. The diagnostic accuracy for 50 and 70% coronary artery stenosis was better with PET irrespective of gender or BMI, and the identification of multivessel disease was also improved. While this study confirmed the superiority of PET, there were some limitations. SPECT attenuation correction was not used and image reconstruction was with filtered back projection, whereas PET images were reconstructed iteratively. The short half-life of 82 Rb means reduced radiation exposure for patients. In our institution, the estimated effective dose for MBq 82 Rb is 2.8 msv (using published dosimetry data 15 and International Commission on Radiological Protection 103 tissue weighting factors). After including the CTAC dose, the total effective dose of 3.6 msv is similar to a CT coronary angiogram and lower than 99m Tc SPECT performed with the current ARSAC maximum diagnostic reference levels 16 (12 msv for MBq 99m Tc-tetrofosmin and 16 msv for 99m Tc-MIBI, plus any additional dose from CTAC, although individual centers may administer less than the recommended maximum). 82 Rb MPS also offers considerable reductions in staff dose due to the short half-life of 82Rb and reduced patient contact during administration. 17 Diagnostic accuracy of perfusion PET The sensitivity and specificityfor the detection of angiographically defined coronary stenosis in the study by Al-Mallah et al was 89% and 90% respectively in 877 patients studied by both 13 N-ammonia and 82 Rb MPS. 18 In the study by Bateman et al., the accuracy of 82 Rb MPSfor the detection of a 70% coronary stenosis was 89%, and for a 50% stenosis it was 87%, which was superior to SPECT (79% and 71% respectively). 14 A meta-analysis by Jaarsma et al. 19 compared the diagnostic accuracy of myocardial perfusion imaging using SPECT, PET and CMR from 166 studies (114 SPECT, 15 PET and 37 CMR. The pooled sensitivities were 88%, 84% and 89% specificities 61%, 81% and 76%, and diagnostic odds ratios 15.3, 36.5 and 26.4 respectively. However this review compared PET and SPECT using all tracers and protocols. Perhaps the most comprehensive review of the diagnostic accuracy of 82 RbMPS was published by Mc Ardle et al. 20 who included Rb and 8 99m Tc studiesbut SPECT studies only with recent technical developments. The pooled sensitivities were 85% and 90% for SPECT and PET, specificities 85% and 88%, and DOR 28.8 and The conclusion was that 82 Rb MPS is more accurate than modern SPECT MPS. British Medical Bulletin 2013;107 93

8 P. Arumugam et al. Prognostic value of PET MPS The prognostic value of SPECT MPS has been established in tens of thousands of patients and a normal scan is associated with an annual hard cardiac event rate of less than 1%. The number of patients included in the PET MPS data is currently in the thousands but data is accumulating and the hard cardiac event rate in a setting of a normal PET MPS is also quoted to be less than 1%. 21 A recent multicentre trial included >7000 patients who underwent 82 Rb MPS and were followed for a mean of 2.2 years. The extent and severity of ischaemia and scar added incremental prognostic value compared with CAD risk factors (age, female sex, BMI, hypertension, diabetes, dyslipidaemia, smoking, angina, beta blocker use, prior revascularization and resting heart rate). 22 PET MPS reclassified risk in terms of cardiac death in 11.6% of patients compared with risk factors and hence potentially changed patient management. The peak stress ejection fraction also adds prognostic value as does the ejection fraction reserve (increase in ejection fraction points during peak stress compared with rest) as reported by Dorbala et al. 23 Clinical application of absolute myocardial blood flow with PET Quantitative PET is likely to be helpful in two groups of patients with multivessel disease balanced ischaemia (Fig. 4) and estimating ischaemia in a territory supplied by less severe stenosis (Fig. 5). Two studies involving a small number of patients showed the diagnostic role of myocardial perfusion and perfusion reserve in patients with multivessel disease. Parkash et al. 4 compared relative perfusion with quantification of 82 Rb retention at stress and at rest. Of the 23 patients, 13 had multivessel disease and the defect size was significantly larger with quantification than with qualitative imaging. In 10 patients with single vessel disease, quantification underestimated defect size slightly. A study assessing 82 Rb myocardial perfusion reserve (MPR) and qualitative imaging in multivessel disease showed that a global perfusion reserve of <2 predicted threevessel disease and a reserve of >2 virtually excluded three-vessel disease. 24 Ziadi et al. 25 demonstrated the independent and incremental prognostic value of MPR using 82 Rb MPS. This prospective study included nearly 700 patients and those with abnormal perfusion reserve had more hard cardiac events than those with a normal perfusion reserve. In addition, all cardiac deaths were in patients with the perfusion reserve <1.5, and a reduced perfusion reserve in a single territory was associated with a higher event rate than with a normal perfusion reserve in all three territories. A larger study by Murthy et al. 26 followed 2783 patients referred for 82 Rb MPS for a 94 British Medical Bulletin 2013;107

9 MPS using rubidium-82 PET Fig. 4 A 77-year-old male presented with NSTEMI (troponin rise but no localizing ECG changes). Coronary angiography showed proximal RCA disease and a probable LMS stenosis. Relative perfusion PET images on the bottom left showed homogenous tracer uptake. However, quantification showed globally impaired MPR in agreement with the angiographic findings. Image reproduced with permission from Cardiology News 2012;15(5). Copyright 2013 Pinpoint Scotland Ltd. median of 1.4 years. Compared with perfusion reserve >2, a perfusion reserve between 1.5 and 2 was associated with a 5.7-fold increased risk and a perfusion reserve <1.5 with a 16-fold increased risk for cardiac death. The addition of perfusion reserve led to the reclassification of 34.8% intermediate-risk patients, and corresponding improvements in risk assessment for mortality from any cause were also seen. The points to deduce from these studies are that a perfusion reserve <2 carries an adverse prognosis even in the presence of normal or mildly abnormal images and a perfusion reserve <1.5 is associated with higher likelihood of cardiac death. PET can also be useful when coronary anatomy is known, because quantification provides accurate information on the functional significance of a coronary lesion and this can be used for management decisions. In patients with CAD, both the hyperaemic response and perfusion reserve are inversely and non-linearly related to stenosis severity. 27 British Medical Bulletin 2013;107 95

10 P. Arumugam et al. Fig. 5 A 57-year-old obese male presented with typical angina. 82 Rb images showed inducible ischaemia in the inferior and inferolateral myocardium (arrow). Quantification however showed global reduction in perfusion reserve including the apparently normally perfused LAD territory (anterior wall and the septum arrowhead). Interestingly, there is evidence of reduced perfusion during adenosine stress compared with rest suggesting coronary steal in the area that is most ischaemic (RCA and LCx territories). Angiography showed chronic occlusion of the RCA, stenosis in the LAD and diffuse LCx disease. Image reproduced with permission from Cardiology News 2012;15(5). Copyright 2013 Pinpoint Scotland Ltd. Another clinical situation where quantification is useful is in heart failure where perfusion reserve can be reduced by microvascular dysfunction. When perfusion reserve is normal, this excludes an ischaemic aetiology for LV dysfunction and confers a better prognosis than when it is reduced 28 (Figs 6 and 7). Cost-effectiveness data An early paper comparing the cost-effectiveness of exercise ECG, SPECT, PET and coronary angiography concluded that in patients with an intermediate pre-test likelihood of CAD, PET is the most cost-effective strategy and in high likelihood patients it is invasive coronary angiography. 29 In a more recent study of intermediate likelihood patients that assessed the impact of 82 Rb MPS compared with SPECT on subsequent invasive 96 British Medical Bulletin 2013;107

11 MPS using rubidium-82 PET Fig. 6 Dilated cardiomyopathy with globally reduced MPR. However, it is difficult to distinguish between balanced three-vessel ischaemia and microvascular dysfunction because of abnormal left ventricle (LV) remodelling. Reduced perfusion reserve is associated with a poor prognosis. Fig. 7 A patient with renal impairment and progressively declining LV systolic function (LVEF 34%). PET perfusion images show hypertrophy with no inducible perfusion abnormality. MPR is normal, which signifies a better prognosis and invasive angiography was avoided. procedures and outcomes, PET reduced the need for invasive angiography and coronary artery bypass grafting by 50% with a 30% cost saving. 30 Disadvantages and limitations of cardiac PET PET cameras are expensive, as are cyclotrons and the 82 Rb generator. This makes it economically non-viable to set up a pure MPS PET service. However, availability of oncology PET scanners has made it feasible to consider MPS PET in departments with a high demand for MPS SPECT. Due to the short half-life of current PET tracers, it is challenging to British Medical Bulletin 2013;107 97

12 P. Arumugam et al. perform exercise studies and hence the majority of patients are stressed pharmacologically. The normal ranges for quantitative stress and rest MBF [and hence myocardial flow reserve (MFR)] vary depending on the tracer used due to the difference in tracer kinetics. Although there is emerging data on how MFR could potentially impact patient management, there is as yet limited cost-effectiveness and outcome data on MPS PET. Clinical MPS PET services in the UK In the USA, there are procedure guidelines and appropriateness criteria for PET MPS with >200 centres routinely using the technique. 31,32 82 Rb and 13 N-ammonia MPS have class I indications for diagnosis and prognostication in patients with intermediate or high likelihood of CAD and a previous inconclusive SPECT study. It has a class IIa indication for patients who are able to exercise or patients with an interpretable ECG as the initial diagnostic non-invasive test. 33 The Evidence based indications for the use of PET CT in the United Kingdom, recommend the use of both 13 N-ammonia and 82 Rb MPS as alternatives to SPECT. 34 Against this 82 Rb MPS is currently available in only two centres: at our institution and at University College Hospital, London. The limiting factor for more widespread use is lack of access to PET scanners because of the high demand for oncology PET scans and the expense of installing a cyclotron or purchasing an 82 Rb generator. Conclusion PET MPS is an emerging technique for non-invasive assessment of myocardial ischaemia with excellent imaging characteristics and tracer kinetics and the ability to quantify myocardial perfusion. 82 Rb MPS is accurate for diagnosis of CAD and there is prognostic benefit from the addition of measurements of perfusion reserve. However, most of the evidence is from single centres with relatively short-term follow-up and it remains to be seen whether these results can be reproduced in larger multicentre trials. For PET MPS, or for any new technique to become main stream, it is not just enough to establish equivalent diagnostic accuracy but also to prove that the test is cost-effective and improves patient outcome. Conflict of interest Parthiban Arumugam has received speakers fee from Siemens Healthcare. The Nuclear Medicine Department at Central Manchester Hospitals has received funding for a PhD student from Siemens Healthcare. 98 British Medical Bulletin 2013;107

13 MPS using rubidium-82 PET References 1 Pijls NHJ, Fearon WF, Tonino PAL et al. Fractional flow reserve versus angiography for guiding percutaneous coronary intervention in patients with multivessel coronary artery disease: 2-year follow-up of the FAME (fractional flow reserve versus angiography for multivessel evaluation) study. J Am Coll Cardiol 2010;56: De Bruyne B, Pijls NHJ, Kalesan B et al. Fractional flow reserve guided PCI versus medical therapy in stable coronary disease. N Engl J Med 2012;367: Shaw LJ, Narula J. Risk assessment and predictive value of coronary artery disease testing. J Nucl Med 2009;50: Parkash R, dekemp RA, Ruddy TD et al. Potential utility of rubidium 82 PET quantification in patients with 3-vessel coronary artery disease. J Nucl Cardiol 2004;11: Knuuti J, Kajander S, Maki M. Quantification of myocardial blood flow will reform the detection of CAD. J Nucl Cardiol 2009;16: Klein R, Beanlands RSB, dekemp RA. Quantification of myocardial blood flow and flow reserve: technical aspects. J Nuc Cardiol 2010;17: Yu M, Nekolla SG, Schwaiger M et al. The next generation of cardiac positron emission tomography imaging agents: discovery of flurpiridaz F-18 for detection of coronary disease. Semin Nucl Med 2011;41: Gould L. Does coronary flow trump coronary anatomy? JACC 2009;2: Ziadiand MC, Beanlands RSB. The clinical utility of assessing myocardial blood flow using positron emission tomography. J Nucl Cardiol 2010;17: El Fakhri G, Kardan A, Sitek A et al. Reproducibility and accuracy of quantitative myocardial blood flow assessment with 82Rb PET: comparison with 13Nammonia PET. J Nucl Med 2009;50: Manabe O, Yoshinaga K, Katoh C et al. Repeatability of rest and hyperemic myocardial blood flow measurements with 82Rb dynamic PET. J Nucl Med 2009;50: Klein R, Renaud JM, Ziadi MC et al. Intra- and inter-operator repeatability of myocardial blood flow and myocardial flow reserve measurements using rubidium-82 PET and a highly automated analysis program. J Nucl Cardiol 2010;17: Ghosh P. A clinical review of myocardial blood flow and coronary flow reserve with dynamic myocardial perfusion PET/CT Bateman TM, Heller GV, McGhie A. Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: comparison with ECG-gated Tc-99 m sestamibi SPECT. J Nucl Cardiol 2006;13: Senthamizhchelvan S, Bravo PE, Lodge MA et al. Radiation dosimetry of Rb-82 in humans under pharmacological stress. J Nuc Med 2011;52: Notes for guidance on the clinical administration of radiopharmaceuticals and use of sealed radioactive sources. Administration of Radioactive Substances Advisory Committee March 2006 (Rev. 2011) Davidson G, Tout D, Hurley C et al. Comparative evaluation of staff dose from myocardial perfusion imaging using 82Rb PET-CT and 99mTc SPECT-CT. Eur J Nucl Med 2011;38(Suppl. 2): Al-Mallah MH, Sitek A, Moore SC et al. Assessment of myocardial perfusion and function with PET and PET/CT. J Nucl Cardiol 2010;17: Jaarsma C, Leiner T, Bekkers SC et al. Diagnostic performance of non-invasive myocardial perfusion imaging using single photon emission computed tomography, cardiac magnetic resonance, and positron emission tomography imaging for the detection of obstructive coronary artery disease: a meta-analysis. JACC 2012;59: Mc Ardle BA, Dowsley TF, dekemp RA et al. Does rubidium-82 PET have superior accuracy to SPECT perfusion imaging for the diagnosis of obstructive coronary disease? JACC 2012;60: Beanlands RSB, Youssef G. Diagnosis and prognosis of coronary artery disease: PET is superior to SPECT: Pro. J Nucl Cardiol 2010;17: British Medical Bulletin 2013;107 99

14 P. Arumugam et al. 22 Dorbala S, Di Carli MF, Beanlands RSB et al. Prognostic value of stress myocardial perfusion positron emission tomography results from a multicenter observational registry. JACC 2013;61: Dorbala S, Vangala D, Sampson U et al. Value of vasodilator left ventricular ejection fraction reserve in evaluating the magnitude of myocardium at risk and the extent of angiographic coronary artery disease: a 82Rb PET/CT study. J Nucl Med 2007;48: Ziadi MC, dekemp RA, Williams K et al. Does quantification of myocardial flow reserve using rubidium-82 positron emission tomography facilitate detection of multivessel coronary artery disease? J Nucl Cardiol 2012;19: Ziadi MC, dekemp RA, Williams K et al. Impaired myocardial flow reserve on rubidium-82 positron emission tomography imaging predicts adverse outcomes in patients assessed for myocardial ischemia. JACC 2011;58: Murthy VL, Naya M, Foster CR et al. Improved cardiac risk assessment with noninvasive measures of coronary flow reserve. Circulation 2011;124: Anagnostopoulos C, Almonacid A, El Fakhri G et al. Quantitative relationship between coronary vasodilator reserve assessed by Rb-82 PET imaging and coronary artery stenosis severity. Eur J Nucl Med Mol Imaging 2008;35: Neglia D, Michelassi C, Trivieri MG et al. Prognostic role of myocardial blood flow impairment in idiopathic left ventricular dysfunction. Circulation 2002;105: Patterson RE, Eisner RL, Horowitz SF. Comparison of cost-effectiveness and utility of exercise ECG, single photon emission computed tomography, positron emission tomography, and coronary angiography for diagnosis of coronary artery disease. Circulation 1995;91: Merhige ME, Breen WJ, Shelton V et al. Impact of myocardial perfusion imaging with PET and Rb-82 on downstream invasive procedure utilization, costs, and outcomes in coronary disease management. J Nucl Med 2007;48: Dilsizian V, Bacharach SL, Beanlands RSB et al. ASNC imaging guidelines for nuclear cardiology procedures. PET myocardial perfusion and metabolism clinical imaging. J Nucl Cardiol 2009; Hendel RC, Berman DS, Di Carli MF et al., American Society of Nuclear Cardiology. Appropriate use criteria for cardiac radionuclide imaging. Circulation 2009;119:e Hendel RC, Berman DS, Di Carli MF et al. Appropriate use criteria for cardiac radionuclide imaging. JACC 2009;53: Barrington S, Scarsbrook A. Evidence based indications for the use of PET CT in the United Kingdom, British Medical Bulletin 2013;107

PET for the Evaluation of Myocardial Viability

PET for the Evaluation of Myocardial Viability PET for the Evaluation of Myocardial Viability Myocardial viability assessment is an important part of cardiac PET to assist physicians to decide upon the best surgical or medical procedures. F-18 FDG

More information

Rubidium-82 myocardial perfusion PET/CT

Rubidium-82 myocardial perfusion PET/CT Rubidium- myocardial perfusion PET/CT A.M. Scholtens, MD 1 ; P.C. Barneveld, MD 2 Departments of Nuclear Medicine of 1 Meander Medical Center, Amersfoort, the Netherlands, and 2 Jeroen Bosch Hospital,

More information

Advantages of PET Myocardial Imaging

Advantages of PET Myocardial Imaging Advantages of PET Myocardial Imaging Legal Disclaimers These materials were prepared in good faith by MITA as a service to the profession and are believed to be reliable based on current scientific literature.

More information

Myocardial Perfusion: Positron Emission Tomography

Myocardial Perfusion: Positron Emission Tomography Myocardial Perfusion: Positron Emission Tomography TH. Schindler, MD University Hospitals of Geneva, Cardiovascular Center, Geneva, Switzerland ESC 2010 Stockholm Personal Disclosure Research Grant support

More information

Conflict of Interest Disclosure

Conflict of Interest Disclosure Comparative Advantages of PET Over SPECT: Is PET Really Better? Timothy M. Bateman M.D. Co-Director, Cardiovascular Radiologic Imaging Mid America Heart Institute Professor of Medicine University of Missouri-Kansas

More information

Promising New Fluorine-18 Labeled Tracers for PET Myocardial Perfusion Imaging

Promising New Fluorine-18 Labeled Tracers for PET Myocardial Perfusion Imaging Journal of Nuclear Medicine, published on July 30, 2015 as doi:10.2967/jnumed.115.161661 Promising New Fluorine-18 Labeled Tracers for PET Myocardial Perfusion Imaging Richard C. Brunken MD, FACC, FAHA,

More information

SPECT or PET for Cardiovascular Screening in High-Risk Patients

SPECT or PET for Cardiovascular Screening in High-Risk Patients SPECT or PET for Cardiovascular Screening in High-Risk Patients Paeng, Jin Chul MD PhD Department of Nuclear Medicine Seoul National University Hospital Contents Recent Development in SPECT and PET Technology

More information

Nuclear Cardiology Cardiac Myocardial Perfusion with 82 Rb. Dominique Delbeke, MD, PhD Vanderbilt University Medical Center Nashville, TN

Nuclear Cardiology Cardiac Myocardial Perfusion with 82 Rb. Dominique Delbeke, MD, PhD Vanderbilt University Medical Center Nashville, TN Nuclear Cardiology Cardiac Myocardial Perfusion with 82 Rb Dominique Delbeke, MD, PhD Vanderbilt University Medical Center Nashville, TN VUMC PET/CT conference 2009 82 Rb Cardiac Perfusion PET 82 Rb is

More information

Pearls & Pitfalls in nuclear cardiology

Pearls & Pitfalls in nuclear cardiology Pearls & Pitfalls in nuclear cardiology Maythinee Chantadisai, MD., NM physician Division of Nuclear Medicine, Department of radiology, KCMH Principle of myocardial perfusion imaging (MPI) Radiotracer

More information

SPECT-CT: Τι πρέπει να γνωρίζει ο Καρδιολόγος

SPECT-CT: Τι πρέπει να γνωρίζει ο Καρδιολόγος SPECT-CT: Τι πρέπει να γνωρίζει ο Καρδιολόγος Δρ Αναστασία Κίτσιου Διευθύντρια, Καρδιολογική Κλινική, Σισμανόγλειο ΓΝΑ Chair, Education Committee, Section on Nuclear Cardiology & Cardiac CT, EACVI, ESC

More information

PET myocard perfusion & viability Riemer Slart

PET myocard perfusion & viability Riemer Slart PET myocard perfusion & viability Riemer Slart Nuclear Medicine Physician Dept. of Nuclear Medicine and Molecular Imaging University Medical Center Groningen, the Netherlands Professor in Molecular Imaging,

More information

CT or PET/CT for coronary artery disease

CT or PET/CT for coronary artery disease CT or PET/CT for coronary artery disease Rotterdam 2012 Juhani Knuuti, MD, PhD, FESC Turku PET Centre University of Turku Turku, Finland Juhani.knuuti@utu.fi Turku PET Centre University of Turku Åbo Akademi

More information

Update in Nuclear Cardiology: Patient-Centered Imaging Radiation Dose Reduction

Update in Nuclear Cardiology: Patient-Centered Imaging Radiation Dose Reduction Update in Nuclear Cardiology: Patient-Centered Imaging Radiation Dose Reduction E. Gordon DePuey, M.D. Icahn School of Medicine ant Mt. Sinai New York, NY Disclosures: Grant Support: Michael J. Fox Foundation

More information

SPECT TRACERS Tl-201, Tc-99m Sestamibi, Tc-99m Tetrofosmin

SPECT TRACERS Tl-201, Tc-99m Sestamibi, Tc-99m Tetrofosmin SPECT TRACERS Tl-201, Tc-99m Sestamibi, Tc-99m Tetrofosmin Elmer Jasper B. Llanes, M.D. Nuclear Cardiology St. Luke s Medical Center Outline Ideal Physiologic Characteristics of MPI radioactive tracers

More information

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

Medical Policy An independent licensee of the Blue Cross Blue Shield Association PET Scanning: Cardiac Applications Page 1 of 31 Medical Policy An independent licensee of the Blue Cross Blue Shield Association Title: Positron Emission Tomography (PET) Scanning: Cardiac Applications

More information

Fundamentals of Nuclear Cardiology. Terrence Ruddy, MD, FRCPC, FACC

Fundamentals of Nuclear Cardiology. Terrence Ruddy, MD, FRCPC, FACC Fundamentals of Nuclear Cardiology Terrence Ruddy, MD, FRCPC, FACC Objectives To understand the Principles of Nuclear Cardiac Imaging Radiotracers Image acquisition and processing Stress protocols To appreciate

More information

Hybrid cardiac imaging Advantages, limitations, clinical scenarios and perspectives for the future

Hybrid cardiac imaging Advantages, limitations, clinical scenarios and perspectives for the future Hybrid cardiac imaging Advantages, limitations, clinical scenarios and perspectives for the future Prof. Juhani Knuuti, MD, FESC Turku, Finland Disclosure: Juhani Knuuti, M.D. Juhani Knuuti, M.D. has financial

More information

Medical Policy. MP Cardiac Applications of Positron Emission Tomography Scanning

Medical Policy. MP Cardiac Applications of Positron Emission Tomography Scanning Medical Policy BCBSA Ref. Policy: 6.01.20 Last Review: 09/19/2018 Effective Date: 09/19/2018 Section: Radiology Related Policies 6.01.51 Interim Positron Emission Tomography Scanning in Oncology to Detect

More information

New Challenges in Nuclear Cardiology Practice

New Challenges in Nuclear Cardiology Practice New Challenges in Nuclear Cardiology Practice Brian G. Abbott, MD, FACC, FASNC, FAHA President, ASNC 2016 Associate Professor of Medicine Warren Alpert Medical School of Brown University Director, Cardiovascular

More information

Atypical pain and normal exercise test

Atypical pain and normal exercise test Atypical pain and normal exercise test F. Mut, M. Beretta Nuclear Medicine Service, Asociacion Española Montevideo, Uruguay Clinical history 67-year old male with several coronary risk factors. Atypical

More information

Detection Of Functional Significance of Coronary Stenoses Using Dynamic. Values Of Myocardial Blood Flow And Coronary Flow Reserve

Detection Of Functional Significance of Coronary Stenoses Using Dynamic. Values Of Myocardial Blood Flow And Coronary Flow Reserve The 2nd International Symposium on Physics, Engineering and Technologies for Biomedicine Volume 2018 Conference Paper Detection Of Functional Significance of Coronary Stenoses Using Dynamic 13 N-Ammonia

More information

Preview of Presentation

Preview of Presentation Preview of Presentation Discuss Healthcare Environment Clinical Implementation of Technical Innovations SNMMI/ASNC Joint Statement on Rb-82 Cardiac PET Imaging Protocol Principles of Rb-82 Cardiac Imaging

More information

Conflict of Interest Disclosure

Conflict of Interest Disclosure Challenges and Opportunities for SPECT & PET in 2013: Implementing Latest Acquisition and Processing Protocols Timothy M. Bateman M.D. Co-Director, Cardiovascular Radiologic Imaging Mid America Heart Institute

More information

Imaging ischemic heart disease: role of SPECT and PET. Focus on Patients with Known CAD

Imaging ischemic heart disease: role of SPECT and PET. Focus on Patients with Known CAD Imaging ischemic heart disease: role of SPECT and PET. Focus on Patients with Known CAD Hein J. Verberne Academic Medical Center, University of Amsterdam, Amsterdam, Netherlands International Conference

More information

RADIOTRACERS FOR MYOCARDIAL PERFUSION IMAGING

RADIOTRACERS FOR MYOCARDIAL PERFUSION IMAGING RADIOTRACERS FOR MYOCARDIAL PERFUSION IMAGING RAYMOND TAILLEFER, M.D. FRCP(c), ABNM DIRECTOR, DEPARTMENT OF NUCLEAR MEDICINE HOPITAL ST-JEAN-SUR-RICHELIEU Disclosures to Report: Grant Research Support:

More information

OTHER NON-CARDIAC USES OF Tc-99m CARDIAC AGENTS Tc-99m Sestamibi for parathyroid imaging, breast tumor imaging, and imaging of other malignant tumors.

OTHER NON-CARDIAC USES OF Tc-99m CARDIAC AGENTS Tc-99m Sestamibi for parathyroid imaging, breast tumor imaging, and imaging of other malignant tumors. DEFINITION OF CARDIAC RADIOPHARMACEUTICAL: A radioactive drug which, when administered for purpose of diagnosis of heart disease, typically elicits no physiological response from the patient. Even though

More information

A Snapshot on Nuclear Cardiac Imaging

A Snapshot on Nuclear Cardiac Imaging Editorial A Snapshot on Nuclear Cardiac Imaging Khalil, M. Department of Physics, Faculty of Science, Helwan University. There is no doubt that nuclear medicine scanning devices are essential tool in the

More information

Cardiology for the Practitioner Advanced Cardiac Imaging: Worth the pretty pictures?

Cardiology for the Practitioner Advanced Cardiac Imaging: Worth the pretty pictures? Keenan Research Centre Li Ka Shing Knowledge Institute Cardiology for the Practitioner Advanced Cardiac Imaging: Worth the pretty pictures? Howard Leong-Poi, MD, FRCPC Associate Professor of Medicine St.

More information

Cardiovascular nuclear imaging employs non-invasive techniques to assess alterations in coronary artery flow, and ventricular function.

Cardiovascular nuclear imaging employs non-invasive techniques to assess alterations in coronary artery flow, and ventricular function. National Imaging Associates, Inc. Clinical guidelines CARDIOVASCULAR NUCLEAR MEDICINE -MYOCARDIAL PERFUSION IMAGING -MUGA Original Date: October 2015 Page 1 of 9 FOR CMS (MEDICARE) MEMBERS ONLY CPT4 Codes:

More information

Gated blood pool ventriculography: Is there still a role in myocardial viability?

Gated blood pool ventriculography: Is there still a role in myocardial viability? Gated blood pool ventriculography: Is there still a role in myocardial viability? Oliver C. Alix, MD Adult Clinical and Nuclear Cardiology St. Luke s Medical Centre - Global City Case Presentation A 62-year-old

More information

Typical chest pain with normal ECG

Typical chest pain with normal ECG Typical chest pain with normal ECG F. Mut, C. Bentancourt, M. Beretta Nuclear Medicine Service, Asociacion Española Montevideo, Uruguay Clinical history Male 41 y.o. Overweight, hypertension, high cholesterol,

More information

Je bénéficie régulièrement de fonds privés, dans le cadre de projets de recherche ou d activités de formation.

Je bénéficie régulièrement de fonds privés, dans le cadre de projets de recherche ou d activités de formation. Je bénéficie régulièrement de fonds privés, dans le cadre de projets de recherche ou d activités de formation. Ces fonds proviennent essentiellement d industriels travaillant dans les domaines de l imagerie

More information

EDITORIAL. Guiding coronary revascularization using PET stress myocardial perfusion imaging: The proof is in the pudding

EDITORIAL. Guiding coronary revascularization using PET stress myocardial perfusion imaging: The proof is in the pudding EDITORIAL Guiding coronary revascularization using PET stress myocardial perfusion imaging: The proof is in the pudding Ajay V. Srivastava, MD, FACC, a and Karthik Ananthasubramaniam, MD FRCP(Glas)FACC

More information

CARDIAC PET PERFUSION IMAGING with RUBIDIUM-82

CARDIAC PET PERFUSION IMAGING with RUBIDIUM-82 CARDIAC PET PERFUSION IMAGING with RUBIDIUM-82 Pr Denis AGOSTINI Président du Groupe de Cardiologie Nucléaire et IRM CHU Caen Bordeaux 2006 Cardiac Perfusion-Metabolism Mismatch with PET Cumulative Survival

More information

Photon Attenuation Correction in Misregistered Cardiac PET/CT

Photon Attenuation Correction in Misregistered Cardiac PET/CT Photon Attenuation Correction in Misregistered Cardiac PET/CT A. Martinez-Möller 1,2, N. Navab 2, M. Schwaiger 1, S. G. Nekolla 1 1 Nuklearmedizinische Klinik der TU München 2 Computer Assisted Medical

More information

Cardiac Imaging Tests

Cardiac Imaging Tests Cardiac Imaging Tests http://www.medpagetoday.com/upload/2010/11/15/23347.jpg Standard imaging tests include echocardiography, chest x-ray, CT, MRI, and various radionuclide techniques. Standard CT and

More information

Myocardial blood flow PET evaluation and quantification. Dr. Erick Alexánderson. Rosas

Myocardial blood flow PET evaluation and quantification. Dr. Erick Alexánderson. Rosas Myocardial blood flow PET evaluation and quantification Dr. Erick Alexánderson Rosas Clinical case 62 year old female patient with a history of DM2 and chronic systemic hypertension She complains of progressive

More information

Long-term outcome after normal myocardial perfusion imaging in suspected ischaemic heart disease

Long-term outcome after normal myocardial perfusion imaging in suspected ischaemic heart disease Dan Med J 65/2 February 2018 DANISH MEDICAL JOURNAL 1 Long-term outcome after normal myocardial perfusion imaging in suspected ischaemic heart disease Pia Hedegaard Johnsen 1, Martin Berg Johansen 1, 2

More information

Cardiovascular nuclear imaging employs non-invasive techniques to assess alterations in coronary artery flow, and ventricular function.

Cardiovascular nuclear imaging employs non-invasive techniques to assess alterations in coronary artery flow, and ventricular function. National Imaging Associates, Inc. Clinical guidelines CARDIOVASCULAR NUCLEAR MEDICINE -MYOCARDIAL PERFUSION IMAGING -MUGA CPT4 Codes: Refer to pages 6-9 LCD ID Number: L33960 J 15 = KY, OH Responsible

More information

CHRONIC CAD DIAGNOSIS

CHRONIC CAD DIAGNOSIS CHRONIC CAD DIAGNOSIS Chest Pain Evaluation 1. Approach to diagnosis of CAD 2. Classification of chest pain 3. Pre-test likelihood CAD 4. Algorithm for chest pain evaluation in women 5. Indications for

More information

Adriano Duatti Department of Chemical and Pharmaceutical Sciences University of Ferrara Via L. Borsari, 46, Ferrara, Italy

Adriano Duatti Department of Chemical and Pharmaceutical Sciences University of Ferrara Via L. Borsari, 46, Ferrara, Italy Adriano Duatti Department of Chemical and Pharmaceutical Sciences University of Ferrara Via L. Borsari, 46, 44121 Ferrara, Italy dta@unife.it adriano.duatti@unife.it Summary Approved tracers for myocardial

More information

Multisclice CT in combination with functional imaging for CAD. Temporal Resolution. Spatial Resolution. Temporal resolution = ½ of the rotation time

Multisclice CT in combination with functional imaging for CAD. Temporal Resolution. Spatial Resolution. Temporal resolution = ½ of the rotation time Multisclice CT in combination with functional imaging for CAD Prof. Juhani Knuuti, MD, FESC Turku University Hospital and University of Turku Turku, Finland MSCT and functional imaging for CAD Practical

More information

Stress only Perfusion Imaging

Stress only Perfusion Imaging European Society of Cardiology Annual meeting, 2010, Stockholm, Sweden Stress only Perfusion Imaging Oliver Gaemperli, MD Cardiovascular Center, University Hospital Zurich, Switzerland Male patient, 48

More information

海外研究留学報告 福島賢慈 東京女子医科大学 画像診断 核医学部 核医学地方会 2011 Jan

海外研究留学報告 福島賢慈 東京女子医科大学 画像診断 核医学部 核医学地方会 2011 Jan 2011 Jan Maryland state (MD), USA Maryland state (MD), USA Baltimore city, MD Baltimore city, MD Myocardial Perfusion PET tracers PET Tracers Half life Production First Pass Extraction Kinetic Properties

More information

Zahid Rahman Khan, MD(USA), MS Diplomate American Board of Nuclear Medicine Consultant t Nuclear Medicine

Zahid Rahman Khan, MD(USA), MS Diplomate American Board of Nuclear Medicine Consultant t Nuclear Medicine Zahid Rahman Khan, MD(USA), MS Diplomate American Board of Nuclear Medicine Consultant t Nuclear Medicine i North West Armed Forces Hospital Tabuk, KSA. 1 Introduction Hibernation: Term coined by Rahimtoola

More information

Myocardial flow reserve (MFR) with positron emission tomography (PET)/computed tomography (CT): clinical impact in diagnosis and prognosis

Myocardial flow reserve (MFR) with positron emission tomography (PET)/computed tomography (CT): clinical impact in diagnosis and prognosis Mini-Review Myocardial flow reserve (MFR) with positron emission tomography (PET)/computed tomography (CT): clinical impact in diagnosis and prognosis Maria Cecilia Ziadi Non-Invasive Cardiovascular Imaging

More information

Abnormal, Autoquant Adenosine Myocardial Perfusion Heart Imaging. ID: GOLD Date: Age: 46 Sex: M John Doe Phone (310)

Abnormal, Autoquant Adenosine Myocardial Perfusion Heart Imaging. ID: GOLD Date: Age: 46 Sex: M John Doe Phone (310) Background: Reason: preoperative assessment of CAD, Shortness of Breath Symptom: atypical chest pain Risk factors: hypertension Under influence: a beta blocker Medications: digoxin Height: 66 in. Weight:

More information

2019 Qualified Clinical Data Registry (QCDR) Performance Measures

2019 Qualified Clinical Data Registry (QCDR) Performance Measures 2019 Qualified Clinical Data Registry (QCDR) Performance Measures Description: This document contains the 18 performance measures approved by CMS for inclusion in the 2019 Qualified Clinical Data Registry

More information

1. LV function and remodeling. 2. Contribution of myocardial ischemia due to CAD, and

1. LV function and remodeling. 2. Contribution of myocardial ischemia due to CAD, and 1 The clinical syndrome of heart failure in adults is commonly associated with the etiologies of ischemic and non-ischemic dilated cardiomyopathy, hypertrophic cardiomyopathy, hypertensive heart disease,

More information

NUCLEAR CARDIOLOGY UPDATE

NUCLEAR CARDIOLOGY UPDATE Nuclear Cardiology David K. Shelton, Jr., MD NUCLEAR CARDIOLOGY UPDATE No Conflicts. No Disclosures. No Smoking. David K. Shelton UCDMC Nuclear Cardiology Nuclear Cardiology Radionuclide Ventriculography

More information

Original Policy Date

Original Policy Date MP 6.01.11 Cardiac Applications of PET Scanning Medical Policy Section Radiology Issue 12:2013 Original Policy Date 12:2013 Last Review Status/Date Reviewed with literature search/12:2013 Return to Medical

More information

PET MYOCARDIAL PERFUSION AND QUANTIFICATION OF FLOW

PET MYOCARDIAL PERFUSION AND QUANTIFICATION OF FLOW PET MYOCARDIAL PERFUSION AND QUANTIFICATION OF FLOW Robert Bober, MD, FACC Director of Nuclear Cardiology and Molecular Imaging John Ochsner Heart and Vascular Institute The Ochsner Clinical School University

More information

Hospital, 6 Lukon Road, Lukong Town, Changhua Shien, Taiwan 505, Taiwan.

Hospital, 6 Lukon Road, Lukong Town, Changhua Shien, Taiwan 505, Taiwan. Volume 1, Issue 1 Image Article Resolution of Inferior Wall Ischemia after Successful Revascularization of LAD Lesion: The Value of Myocardial Perfusion Imaging in Guiding Management of Multi-vessel CAD

More information

Diagnosis of CAD S Richard Underwood

Diagnosis of CAD S Richard Underwood Diagnosis of CAD S Richard Underwood Professor of Cardiac Imaging Royal Brompton Hospital & Imperial College Faculty of Medicine London, UK The history and diagnosis 89% Non-cardiac chest pain 50% Atypical

More information

Qualitative and Quantitative Assessment of Perfusion

Qualitative and Quantitative Assessment of Perfusion APCDE 2011 Qualitative and Quantitative Assessment of Perfusion Hyun Ju Yoon Chonnam National University Hospital Gwangju, Korea ISCHEMIC CASCADE Blood flow mismatch Perfusion defects on nuclear imaging,

More information

Multiple Gated Acquisition (MUGA) Scanning

Multiple Gated Acquisition (MUGA) Scanning Multiple Gated Acquisition (MUGA) Scanning Dmitry Beyder MPA, CNMT Nuclear Medicine, Radiology Barnes-Jewish Hospital / Washington University St. Louis, MO Disclaimers/Relationships Standard of care research

More information

O is characterized by different kinetic properties as compared with 13 NH 3

O is characterized by different kinetic properties as compared with 13 NH 3 13 N-ammonia and H 2 O PET/CT of Myocardial Perfusion P. Raijmakers, VUmc Amsterdam 1. Introduction Coronary artery disease (CAD) is a major cause of death in the modern world. The diagnosis of CAD is

More information

Does Rubidium-82 PET Have Superior Accuracy to SPECT Perfusion Imaging for the Diagnosis of Obstructive Coronary Disease?

Does Rubidium-82 PET Have Superior Accuracy to SPECT Perfusion Imaging for the Diagnosis of Obstructive Coronary Disease? Journal of the American College of Cardiology Vol. 60, No. 18, 2012 2012 by the American College of Cardiology Foundation ISSN 0735-1097/$36.00 Published by Elsevier Inc. http://dx.doi.org/10.1016/j.jacc.2012.07.038

More information

Tc-99m Sestamibi/Tetrofosmin Stress-Rest Myocardial Perfusion Scintigraphy

Tc-99m Sestamibi/Tetrofosmin Stress-Rest Myocardial Perfusion Scintigraphy APPROVED BY: Director of Radiology Page 1 of 6 Tc-99m Sestamibi/Tetrofosmin Stress-Rest Myocardial Primary Indications: Evaluation of myocardial perfusion and viability in patients with known or suspected

More information

Prognostic Value of Stress Myocardial Perfusion Positron Emission Tomography

Prognostic Value of Stress Myocardial Perfusion Positron Emission Tomography Journal of the American College of Cardiology Vol. 61, No. 2, 2013 2013 by the American College of Cardiology Foundation ISSN 0735-1097/$36.00 Published by Elsevier Inc. http://dx.doi.org/10.1016/j.jacc.2012.09.043

More information

msv Stress dose (mci) Stress dose (MBq)

msv Stress dose (mci) Stress dose (MBq) Supplemental Table 1. A Sample Weight Based Dosing for 99m Tc Sestamibi MPI Using a Dedicated Cardiac SPECT Scanner Weight range Rest (mci) Rest (MBq) msv Stress (mci) Stress (MBq) msv Total msv (rest

More information

Hybrid imaging of the heart

Hybrid imaging of the heart Pärnu (Estonia) Friday, October 10, 2014 8:00-8:30 a.m Hybrid imaging of the heart María José García Velloso Servicio de Medicina Nuclear Clínica Universidad de Navarra mjgarciave@unav.es Hibrid imaging

More information

Cardiac PET. John Buscombe

Cardiac PET. John Buscombe Cardiac PET John Buscombe Why PET? Improved resolution-not really required in cardiology Improved sensitivity this may be important-financially as reduced acquisition time Improved attenuation correction-good

More information

The Value of Stress MRI in Evaluation of Myocardial Ischemia

The Value of Stress MRI in Evaluation of Myocardial Ischemia The Value of Stress MRI in Evaluation of Myocardial Ischemia Dr. Saeed Al Sayari, MBBS, EBCR, MBA Department of Radiology and Nuclear Medicine Mafraq Hospital, Abu Dhabi United Arab Emirates Introduction

More information

Evidence-Based Management of CAD: Last Decade Trials and Updated Guidelines

Evidence-Based Management of CAD: Last Decade Trials and Updated Guidelines Evidence-Based Management of CAD: Last Decade Trials and Updated Guidelines Enrico Ferrari, MD Cardiac Surgery Unit Cardiocentro Ticino Foundation Lugano, Switzerland Conflict of Interests No conflict

More information

Evidence for myocardial CT perfusion imaging in the diagnosis of hemodynamically significant coronary artery disease

Evidence for myocardial CT perfusion imaging in the diagnosis of hemodynamically significant coronary artery disease Editorial Evidence for myocardial CT perfusion imaging in the diagnosis of hemodynamically significant coronary artery disease Zhonghua Sun Discipline of Medical Imaging, Department of Imaging and Applied

More information

Radionuclide myocardial perfusion imaging (MPI) currently

Radionuclide myocardial perfusion imaging (MPI) currently Contemporary Reviews in Cardiovascular Medicine Integration of Quantitative Positron Emission Tomography Absolute Myocardial Blood Flow Measurements in the Clinical Management of Coronary Artery Disease

More information

Cardiac Imaging. Kimberly Delcour, DO, FACC. Mahi Ashwath, MD, FACC, FASE. Director, Cardiac CT. Director, Cardiac MRI

Cardiac Imaging. Kimberly Delcour, DO, FACC. Mahi Ashwath, MD, FACC, FASE. Director, Cardiac CT. Director, Cardiac MRI Cardiac Imaging Kimberly Delcour, DO, FACC Director, Cardiac CT Mahi Ashwath, MD, FACC, FASE Director, Cardiac MRI Cardiac Imaging Discuss the clinical applications of and indications for: Cardiac CT Nuclear

More information

EMPHISIS ON PHYSIOLOGY PHYSIOLOGY REQUIRES TIME QUALITATIVE vs. QUANTITATIVE ISOTOPES TO RADIOPHARMACEUTICALS

EMPHISIS ON PHYSIOLOGY PHYSIOLOGY REQUIRES TIME QUALITATIVE vs. QUANTITATIVE ISOTOPES TO RADIOPHARMACEUTICALS 1926 Herman Blumgard used solutions of radon gas to measure what he called velocity of the circulation. 1927 Blumberg and Soma Weiss wrote article in (Journal of Clinical Investigation) 1929 Werner Forssmann

More information

Technical Meeting on: Current Role of Nuclear Cardiology in the Management of Cardiac Diseases Vienna, May 2008 Vienna International Centre

Technical Meeting on: Current Role of Nuclear Cardiology in the Management of Cardiac Diseases Vienna, May 2008 Vienna International Centre Technical Meeting on: Current Role of Nuclear Cardiology in the Management of Cardiac Diseases Vienna, 5-95 9 May 2008 Vienna International Centre Evidence-based Nuclear Cardiology: Imaging of CAD The

More information

Role of Myocardial Perfusion Imaging in the Cardiac Evaluation of Aviators

Role of Myocardial Perfusion Imaging in the Cardiac Evaluation of Aviators Original Research Role of Myocardial Perfusion Imaging in the Cardiac Evaluation of Aviators Anil Kumar AVS *, Kumar PG +, Prakash MS # ABSTRACT In an attempt to provide more accurate and inclusive information

More information

Myocardial Perfusion SPECT How to do it E. Moralidis

Myocardial Perfusion SPECT How to do it E. Moralidis Myocardial Perfusion SPECT How to do it E. Moralidis Aristotelian University AHEPA Hospital Thessaloniki Myocardial perfusion SPECT procedure Stress Imaging Data analysis and reporting Myocardial perfusion

More information

MPS and Calcium Score in asymptomatic patient F. Mut, J. Vitola

MPS and Calcium Score in asymptomatic patient F. Mut, J. Vitola MPS and Calcium Score in asymptomatic patient F. Mut, J. Vitola Nuclear Medicine Service, Asociacion Española Montevideo, Uruguay Quanta Diagnostico Nuclear Curitiba, Brazil Clinical history Male 63 y.o.,

More information

Nuclear Cardiology Pierre-Yves MARIE Department of Nuclear Medicine CHU-Nancy, FRANCE.

Nuclear Cardiology Pierre-Yves MARIE Department of Nuclear Medicine CHU-Nancy, FRANCE. Nuclear Cardiology Pierre-Yves MARIE Department of Nuclear Medicine CHU-Nancy, FRANCE. Nuclear Cardiology I - A remaining need of a functional information on myocardial perfusion II - The future: - combining

More information

The Role of Nuclear Imaging in Heart Failure

The Role of Nuclear Imaging in Heart Failure The Role of Nuclear Imaging in Heart Failure Mouaz H. Al-Mallah, MD MSc FESC Associate Professor of Medicine Consultant Cardiologist and Division Head, Cardiac Imaging King Abdulaziz Cardiac Centre, National

More information

Radiologic Assessment of Myocardial Viability

Radiologic Assessment of Myocardial Viability November 2001 Radiologic Assessment of Myocardial Viability Joshua Moss, Harvard Medical School Year III Patient EF 66yo female with a 3-year history of intermittent chest pain previously relieved by sublingual

More information

FFR Incorporating & Expanding it s use in Clinical Practice

FFR Incorporating & Expanding it s use in Clinical Practice FFR Incorporating & Expanding it s use in Clinical Practice Suleiman Kharabsheh, MD Consultant Invasive Cardiology Assistant professor, Alfaisal Univ. KFHI - KFSHRC Concept of FFR Maximum flow down a vessel

More information

Positron emission tomography and molecular imaging

Positron emission tomography and molecular imaging Positron emission tomography and molecular imaging EHH, May, 2010 Juhani Knuuti Turku PET Centre University of Turku Turku, Finland Juhani.knuuti@utu.fi PET Imaging in Medicine MRI CT MRI PET US SPET MEG

More information

Nuclear Perfusion Imaging of Angina

Nuclear Perfusion Imaging of Angina January 2002 Nuclear Perfusion Imaging of Angina Davin Quinn HMS III Beth Israel Deaconess Medical Center Radiology Department Goals of Presentation Understand what a perfusion scan is Understand what

More information

2017 Qualified Clinical Data Registry (QCDR) Performance Measures

2017 Qualified Clinical Data Registry (QCDR) Performance Measures 2017 Qualified Clinical Data Registry (QCDR) Performance Measures Description: This document contains the 15 performance measures that were approved by CMS for use in ASC's 2017 Qualified Clinical Data

More information

Debate Should we use FFR? I will say NO.

Debate Should we use FFR? I will say NO. Debate Should we use FFR? I will say NO. Hyeon-Cheol Gwon Cardiac and Vascular Center Samsung Medical Center Sungkyunkwan University School of Medicine Dr. Hyeon-Cheol Gwon Research fund from Abbott Korea

More information

Rational use of imaging for viability evaluation

Rational use of imaging for viability evaluation EUROECHO and other imaging modalities 2011 Rational use of imaging for viability evaluation Luc A. Pierard, MD, PhD, FESC, FACC Professor of Medicine Head, Department of Cardiology, CHU Liège, Belgium

More information

Fractional Flow Reserve from Coronary CT Angiography (and some neat CT images)

Fractional Flow Reserve from Coronary CT Angiography (and some neat CT images) Fractional Flow Reserve from Coronary CT Angiography (and some neat CT images) Victor Cheng, M.D. Director, Cardiovascular CT Oklahoma Heart Institute 1 Disclosures Tornadoes scare me 2 Treating CAD Fixing

More information

PET: quantification of perfusion and beyond

PET: quantification of perfusion and beyond PET: quantification of perfusion and beyond Juhani Knuuti Turku PET Centre University of Turku Turku, Finland Juhani.knuuti@utu.fi 27.8.2012 1 Disclosure: Juhani Knuuti, M.D. Juhani Knuuti, M.D. has financial

More information

Validation of CT Perfusion Imaging Against Invasive Angiography and FFR on a 320-MDCT Scanner

Validation of CT Perfusion Imaging Against Invasive Angiography and FFR on a 320-MDCT Scanner Validation of CT Perfusion Imaging Against Invasive Angiography and FFR on a 320-MDCT Scanner Zhen Qian, Gustavo Vasquez, Sarah Rinehart, Parag Joshi, Eric Krivitsky, Anna Kalynych, Dimitri Karmpaliotis,

More information

Perspectives of new imaging techniques for patients with known or suspected coronary artery disease

Perspectives of new imaging techniques for patients with known or suspected coronary artery disease Perspectives of new imaging techniques for patients with known or suspected coronary artery disease Department of Cardiology, Leiden University Medical Center, Leiden, The Netherlands Correspondence: Jeroen

More information

Myocardial viability testing. What we knew and what is new

Myocardial viability testing. What we knew and what is new Myocardial viability testing. What we knew and what is new Dr B K S Sastry, MD, DM. CARE Hospitals, Hyderabad What is Viability Viability Dysfunctional myocardium subtended by diseased coronary arteries

More information

Horizon Scanning Technology Summary. Magnetic resonance angiography (MRA) imaging for the detection of coronary artery disease

Horizon Scanning Technology Summary. Magnetic resonance angiography (MRA) imaging for the detection of coronary artery disease Horizon Scanning Technology Summary National Horizon Scanning Centre Magnetic resonance angiography (MRA) imaging for the detection of coronary artery disease April 2007 This technology summary is based

More information

Cardiac Applications of Positron Emission Tomography Scanning

Cardiac Applications of Positron Emission Tomography Scanning 6.01.20 Cardiac Applications of Positron Emission Tomography Scanning Section 6.0 Radiology Subsection Effective Date December 15, 2014 Original Policy Date December 15, 2014 Next Review Date December

More information

Click here for Link to References: CMS Website HOPPS CY 2018 Final Rule. CMS Website HOPPS CY2018 Final Rule Updated November 2017.

Click here for Link to References: CMS Website HOPPS CY 2018 Final Rule. CMS Website HOPPS CY2018 Final Rule Updated November 2017. Final Compared to 3Q 2017 Rates Medicare Hospital Outpatient Prospective Payment System HOPPS () Nuclear Cardiology Procedures, Radiopharmaceuticals, and Drugs Click here for Link to References: CMS Website

More information

The diagnostic role of stress echocardiography in women with coronary artery disease: evidence based review John R. McKeogh

The diagnostic role of stress echocardiography in women with coronary artery disease: evidence based review John R. McKeogh The diagnostic role of stress echocardiography in women with coronary artery disease: evidence based review John R. McKeogh Key points 1) Coronary artery disease in women differs from men in several ways,

More information

DOWNLOAD PDF MYOCARDIAL CONTRAST TWO DIMENSIONAL ECHOCARDIOGRAPHY (DEVELOPMENTS IN CARDIOVASCULAR MEDICINE)

DOWNLOAD PDF MYOCARDIAL CONTRAST TWO DIMENSIONAL ECHOCARDIOGRAPHY (DEVELOPMENTS IN CARDIOVASCULAR MEDICINE) Chapter 1 : Imaging Cardiovascular Medicine Stanford Medicine contrast two-dimensional echocardiography (MC-2DE), a new and exciting diagnostic methodology for assessment of myocardial perfusion, which

More information

Fellows on this rotation are expected to attend nuclear conferences and multimodality imaging conference.

Fellows on this rotation are expected to attend nuclear conferences and multimodality imaging conference. Rotation: Imaging 1 Imaging 1 provides COCATS Level 1 experience for nuclear cardiology (including SPECT and PET) and cardiac CT. Fellows will administer, process, and read cardiac nuclear studies with

More information

Optimal testing for coronary artery disease in symptomatic and asymptomatic patients

Optimal testing for coronary artery disease in symptomatic and asymptomatic patients Optimal testing for coronary artery disease in symptomatic and asymptomatic patients Alexandre C Ferreira, MD Clinical Chief of Cardiology Jackson Health System Director, Interventional Cardiology Training

More information

I have no financial disclosures

I have no financial disclosures Manpreet Singh MD I have no financial disclosures Exercise Treadmill Bicycle Functional capacity assessment Well validated prognostic value Ischemic assessment ECG changes ST segments Arrhythmias Hemodynamic

More information

Evidence for Everyone: Expanding the Reach of Health Technology Assessment 2016 CADTH Symposium, April 10-12, Shaw Centre, Ottawa

Evidence for Everyone: Expanding the Reach of Health Technology Assessment 2016 CADTH Symposium, April 10-12, Shaw Centre, Ottawa Dr. Ross Davies President Dr. Benjamin Chow Vice-President Dr. Jonathan Leipsic Secretary/Treasurer Office 222 Queen Street Suite 1403 Ottawa, ON K1P 5V9 www.ccs.ca/ nuclear_ct@ccs.ca Evidence for Everyone:

More information

EDITORIAL POINT OF VIEW. Quantification of myocardial blood flow will reform the detection of CAD

EDITORIAL POINT OF VIEW. Quantification of myocardial blood flow will reform the detection of CAD EDITORIAL POINT OF VIEW Quantification of myocardial blood flow will reform the detection of CAD Juhani Knuuti, MD, Sami Kajander, MD, Maija Mäki, MD, and Heikki Ukkonen, MD INTRODUCTION The detection

More information

Cardiac Diagnostics Workshop. Lori Savard NP Cardiology Update 2015

Cardiac Diagnostics Workshop. Lori Savard NP Cardiology Update 2015 Cardiac Diagnostics Workshop Lori Savard NP Cardiology Update 2015 Disclosure of Commercial Support Potential for conflict(s) of interest: none Objectives Increase understanding regarding stable IHD and

More information

Myocardial perfusion imaging in women for the evaluation of stable ischemic heart disease-state-of-the-evidence and clinical recommendations

Myocardial perfusion imaging in women for the evaluation of stable ischemic heart disease-state-of-the-evidence and clinical recommendations Myocardial perfusion imaging in women for the evaluation of stable ischemic heart disease-state-of-the-evidence and clinical recommendations Viviany R. Taqueti, Brigham and Women s Hospital Sharmila Dorbala,

More information

Use of Nuclear Cardiology in Myocardial Viability Assessment and Introduction to PET and PET/CT for Advanced Users

Use of Nuclear Cardiology in Myocardial Viability Assessment and Introduction to PET and PET/CT for Advanced Users Use of Nuclear Cardiology in Myocardial Viability Assessment and Introduction to PET and PET/CT for Advanced Users February 1 5, 2011 University of Santo Tomas Hospital Angelo King A-V Auditorium Manila,

More information