1596 TANAKA N et al. Circ J 2017; 81: ORIGINAL ARTICLE doi: /circj.CJ

Size: px
Start display at page:

Download "1596 TANAKA N et al. Circ J 2017; 81: ORIGINAL ARTICLE doi: /circj.CJ"

Transcription

1 1596 TANAKA N et al. Circ J 2017; 81: ORIGINAL ARTICLE doi: /circj.CJ Arrhythmia/Electrophysiology Automated Ablation Annotation Algorithm Reduces Re-conduction of Isolated Pulmonary Vein and Improves Outcome After Catheter Ablation for Atrial Fibrillation Nobuaki Tanaka, MD; Koichi Inoue, MD, PhD; Koji Tanaka, MD; Yuko Toyoshima, MD; Takafumi Oka, MD, PhD; Masato Okada, MD; Hiroyuki Inoue, MD; Ryo Nakamaru, MD; Yasushi Koyama, MD, PhD; Atsunori Okamura, MD, PhD; Katsuomi Iwakura, MD, PhD; Yasushi Sakata, MD, PhD; Kenshi Fujii, MD, PhD Background: Durable pulmonary vein isolation (PVI) is critical in reducing recurrence after radiofrequency catheter ablation for atrial fibrillation (AF). The VISITAG Module, an automatic annotation system that takes account of catheter stability and contact force (CF), might be useful in accomplishing this. Methods and Results: In 49 patients undergoing VISITAG-guided AF ablation (group A), we set the following automatic annotation criteria: catheter stability range of motion 1.5 mm, duration 5 s, CF 5 g, time 25% and tag diameter at 6 mm. We used ablation >20 s and force-time integral >150 gs at each site, then moved to the next site where a new tag appeared that overlapped with the former tag. Results and outcome were retrospectively compared for 42 consecutive patients undergoing CF-guided AF ablation without this algorithm (group B). Successful PVI at completion of the initial anatomical line was more frequent in group A than B (66.3% vs. 36.9%, P=0.0006) while spontaneous PV reconnection was less frequent (14.2% vs. 30.9%, P=0.0014) and procedure time was shorter (138±35 min vs. 180±44 min, P<0.001). One-year success rate off anti-arrhythmic drugs was higher in group A (91.8% vs. 69.1%, log rank P=0.0058). Conclusions: An automated annotation algorithm with an optimal setting reduced acute resumption of left atrium-pv conduction, shortened procedure time, and improved AF ablation outcome. Key Words: Atrial fibrillation; Automated ablation annotation algorithm; Pulmonary vein isolation Catheter ablation (CA) is an effective therapy of atrial fibrillation (AF). The cornerstone of CA for AF is pulmonary vein isolation (PVI). 1,2 Despite initially successful PVI, however, recurrence of AF after CA occurs frequently and is often related to the recovery of conduction between the pulmonary vein (PV) and left atrium (LA). 3 5 Contact force (CF) monitoring of the ablation catheter might help achieve more durable lesions and substantially improve procedural outcomes. 6 A recent randomized, multicenter study, however, showed that CF data availability was associated with reduced acute PV reconnections but not improved 1-year success rates, procedure and fluoroscopy times, or complication rates. 7 The failure of CF monitoring to improve clinical outcome of AF ablation might be due to a lack of information on the catheter stability as well as the precise location of ablated lesions, and subsequent heterogeneous ablation intensity. A new ablation annotation system (CARTO3 System, VISITAG Module) uses an algorithm for the automated annotation of RF ablation applications based on objective, predefined parameters. Because it provides crucial information on catheter stability and ablation intensity at each site, it may be helpful in accomplishing durable PVI. The aim of this study was therefore to evaluate the utility of automated ablation lesion annotation by comparing procedure parameters and outcomes between automated annotation-guided and non-guided procedures. Methods Subjects The study was conducted under a retrospective, singlecenter observational design. We included 91 AF patients who underwent initial PVI by an experienced operator between June 2013 and January We performed 51 initial AF ablations from June 2014 to January We Received March 2, 2017; revised manuscript received April 20, 2017; accepted May 4, 2017; released online June 2, 2017 Time for primary review: 19 days Cardiovascular Center, Sakurabashi-Watanabe Hospital, Osaka (N.T., K. Inoue, K.T., Y.T., T.O., M.O., H.I., R.N., Y.K., A.O., K. Iwakura, K.F.); Department of Cardiovascular Medicine, Osaka University Graduate School of Medicine, Suita (Y.S.), Japan Mailing address: Koichi Inoue, MD, PhD, Department of Cardiology, Sakurabashi-Watanabe Hospital, Umeda, Kita-ku, Osaka , Japan. koichi@inoue.name ISSN All rights are reserved to the Japanese Circulation Society. For permissions, please cj@j-circ.or.jp

2 PVI: Guided Novel Annotation 1597 Figure 1. Initial anatomical PVI line in (A) group A and (B) group B. (A) Annotation of ablation lesions during pulmonary vein isolation (PVI) was performed using an automated algorithm with predefined criteria for a catheter stability range of motion 1.5 mm and catheter stability duration >5 s (right anterior oblique [RAO], anteroposterior [AP] and left anterior oblique [LAO] view). White automated annotation tag, force-time integral (FTI) <100 gs; pink automated annotation tag, 100 gs FTI<150 gs; red automated annotation tag, FTI 150 gs. (B) In control group B, PVI was performed using contact force-guided ablation with manual annotation (RAO, AP and LAO view). excluded from the study 2 patients who underwent empirical liner ablation in addition to PVI. The remaining 49 patients underwent AF ablation using automated annotation algorithm-guided PVI (group A; n=49). The comparison group consisted of 42 consecutive patients who underwent CF-guided PVI without automated annotation algorithm from June 2013 to December 2013 (group B; n=42). We did not include patients treated from January 2014 to May 2014 because PVI during this period was performed using different methods and annotation parameters. In total, the treatment groups consisted of 79 men and 12 women (mean age, 60.4±11.3 years). Fifty-eight patients had paroxysmal AF (PaF) and the other 33 patients had non-paroxysmal AF (non-paf). Adequate oral anticoagulation was maintained for at least 1 month before the procedure. Warfarin was interrupted 1 day before the procedure and was restarted in the evening of the day of the procedure. Dabigatran, rivaroxaban and apixaban were omitted only on the morning of the procedure. The absence of thrombus in the LA was confirmed on transesophageal echocardiography the day before PVI. Anti-arrhythmic drugs (AAD) were stopped for at least 5 half-lives before the procedure. Transesophageal echocardiography was performed in all patients after admission. All patients gave informed consent for the ablation procedures and the use of their clinical data in a retrospective study. The study protocol was approved by the institutional ethics committee. LA Multi-Detector Computed Tomography All patients underwent multi-detector computed tomography (MDCT) with a 160-detector row, dynamic volume scanner for 3-D reconstruction of the LA and PV within the week prior to the ablation procedure using a 64-slice MDCT scanner (Brilliance CT 64, Phillips Medical Systems, Cleveland, OH, USA). A bolus of non-ionic iodinated contrast (Iopamirone 370; Bayer Yakuhin, Osaka, Japan) was injected through an antecubital vein at a flow rate of 0.67 ml/min/kg for 15 s, followed by a saline bolus flush. The scan was initiated according to the bolus-tracking method (6 s after the threshold of 120 Hounsfield units in the descending aorta). Cardiac images from the carina to the apex of the heart were acquired during a single breathhold at the end-tidal position. 3-D CT was reconstructed at 50% of the R-R interval and recorded as DICOM data. Cardiac Catheterization A 6-Fr decapolar catheter was placed in the coronary sinus via the median antebrachial vein, while a 7-Fr decapolar catheter was placed in the superior vena cava and right atrium and a 10-Fr SoundStar ultrasound catheter (Biosense Webster, Diamond Bar, CA, USA) was inserted into right atrium via the femoral vein. Anatomic mapping of the LA using the CartoSound module of a CARTO3 system (Biosense Webster) was performed. Two long sheaths (Daig SL0; St Jude Medical, St Paul, MN, USA) were introduced into the LA using a single trans-septal puncture technique via the femoral vein. An initial i.v. bolus of heparin (150 IU/kg) was followed by continuous infusion to maintain an activated clotting time >300 s. PV angiography was performed by injecting a contrast medium through the trans-septal long sheaths into the LA. Conscious sedation was achieved with a combination of bolus thiamylal sodium and continuous dexmedetomidine hydrochloride. Patient respiration was controlled using bi-level positive airway pressure in all cases. Integration of CARTO With CT The ICE (intracardiac echocardiography) images were displayed through the CartoSound module using an echocardiography system (Vivid i, GE). ICE LA plane images were obtained at the end-tidal position and at the end of the T wave. Five to eight contours were sampled between the ostia of the right PV and the left PV, all of which were registered as the LA ICE image. These 2 images were then integrated with the installed surface registration system.

3 1598 TANAKA N et al. Table 1. Baseline Patient Characteristics Variable Group A (n=49) Group B (control) (n=42) Age (years) 60.8± ± Male 43 (87) 36 (85) 0.77 Height (cm) 169.3± ± Weight (kg) 71.9± ± Type of AF Paroxysmal 28 (57) 30 (71) 0.15 Persistent 15 (31) 7 (17) Long-lasting 6 (12) 5 (12) CHADS2 score 0, 1 36 (73) 35 (83) (14) 4 (10) 3 6 (12) 3 (7) Hypertension 36 (73) 18 (43) Diabetes mellitus 8 (16) 4 (10) 0.33 History of HF 3 (6) 3 (7) 0.84 Prior stroke or TIA 3 (6) 1 (2) 0.37 LAD (mm) 39.6± ± LVEF (%) 65.5± ± Data given as mean ± SD or n (%). AF, atrial fibrillation; HF, heart failure; LAD, left atrial dimension; LVEF, left ventricular ejection fraction; TIA, transient ischemic attack. Automated Annotation Algorithm Setting We set the parameters of the automated ablation annotation system (Carto 3 System, VISITAG Module, Biosense Webster) as follows: (1) catheter stability range of motion 1.5 mm; (2) catheter stability duration >5s, and (3) CF 5 g, time 25%. Tag size was 6 mm in diameter. We intended to ablate thickly so that each tag overlapped the other. We set the minimum force-time integral (FTI) as 150 gs, and attempted to meet or exceed this level at each ablation site. AF Ablation Procedures were performed by integrating the 3-D image using an open-irrigated ThermoCoolSmartTouch catheter (Biosense Webster) and a circular mapping catheter (Lasso, Biosense Webster; adjustable circumference, mm; interelectrode pacing, 1 2 mm) in all patients. We performed ipsilateral circumferential PVI in sinus rhythm except in subjects with persistent AF refractory to electrical cardioversion. The present CF was measured based on electromagnetic location technology. RF energy was delivered using a dragging method at W except at the site near the esophagus, where we delivered W RF energy using a Stockert 70 (Biosense Webster) RF generator. The upper temperature limit was set to 43 C and saline irrigation flow was ml/min (Cool Flow Pump; Biosense Webster). In (group A) 49 patients undergoing AF ablation from June 2014 to January 2015 who received circumferential PVI, RF ablation was guided by the ablation annotation system (Carto 3 System, VISITAG Module, Biosense Webster) using an algorithm for the automated annotation of RF ablation based on objective, predefined parameters as noted. The new tag appeared automatically when all these conditions were satisfied. We set the FTI parameter at gs. As FTI increased from 100 gs to 150 gs, the color of the tag gradually changed from white to red. We ablated for at least 20 s at each site, and continued ablation until the tag turned red. Near the esophagus, we aborted RF delivery before the temperature of the esophagus reached 40 C, as monitored with a SensiTherm (St. Jude Medical). Tag size was 6 mm in diameter, and we intended to move the catheter to the next position such that the new tag overlapped the preceding tag (Figure 1A). We continued to ablate each site for >20 s and until the tag turned red even when the local PV potential had disappeared. The 42 control patients (group B) undergoing AF ablation from June 2013 to December 2013 received PVI with CF monitoring but without the use of an automated algorithm (Figure 1B). The ablation strategy and energy settings were similar to that used for group A. We attempted to maintain CF between 10 g and 20 g and moved the RF catheter to the next position every s. We continued to ablate each site for >20 s even when the local PV potential had disappeared. Successful PVI was defined as the loss of PV potentials (entrance block) and failure to capture LA during pacing from all bipoles of the circular multielectrode mapping catheter when positioned at the PV ostium (output, 10 ma; pulse width, 2 ms; exit block). Persistent isolation (entrance and exit block) for each PV was confirmed after a waiting period 20 min. Dormant conduction was evaluated for each PV separately with i.v. adenosine (triphosphate) at a dose of 0.4 mg/kg body weight under back-up pacing from the right ventricle in 74 patients after persistent block was documented. If ATP triggered dormant conduction, additional ablation was delivered at areas in which the earliest activation was transiently observed on the circular mapping catheter. I.v. ATP was repeated until dormant conduction was no longer present. We also attempted to ablate non-pv premature atrial contractions, including the superior vena cava, if they triggered AF or appeared frequently on continuous i.v. injection of isoproterenol. When atrial flutter or atrial tachycardia was induced by atrial rapid pacing, we eliminated it by also performing linear ablation of the

4 PVI: Guided Novel Annotation 1599 Table 2. Procedural Parameters Variable Group A (n=49) Group B (control) (n=42) CTI 18 (35) 9 (21) 0.14 Procedure time (min) 138±35 180±44 < Mean CF (g) 12.6± ±2.9 < RF energy application time (min) 30.5± ± Total fluoroscopy time (min) 32.0± ± Total fluoroscopy dose (mgy) 65 (36 116) 90 (61 154) No. annotated ablation tags 76.6± ± Complications 0 (0) 1 (2) NS Data given as mean ± SD, median (IQR) or n (%). Pericardial effusion not requiring drainage. CF, contact force; CFAE, complex fractionated atrial electrogram; CTI, cavotricuspid isthmus line; RF, radiofrequency. cavotricuspid isthmus, LA roof, and mitral valve isthmus and focal atrium tachycardia ablation. We did not perform empiric linear ablation or defragmentation. Follow-up All patients were hospitalized under continuous rhythm monitoring for 3 days after the ablation procedure. We directed patients to check their pulse rate and rhythm 3 times per day and to visit the outpatient clinic if they experienced a relapse of AF. All patients were scheduled for visits to the outpatient clinic at 1, 2, 3, 6, 9, and 12 months after ablation. Electrocardiogram was obtained at each visit. Holter electrocardiogram was performed at 6 months after the procedure. Additional monitoring was performed on the basis of symptoms. A 3-month blanking period after ablation was used. AAD were discontinued at 3 months after the procedure. Freedom from atrial tachyarrhythmia was defined as the absence of AF, atrial flutter, or atrial tachycardia lasting >30 s off AAD. Statistical Analysis Descriptive statistics are reported as mean ± SD or median (IQR) for continuous variables and as absolute frequencies and percentages for categorical variables. Continuous variables were compared using parametric and non-parametric testing based on data distribution. Categorical variables were compared using the chi-squared or Fisher exact test. Event-free survival was reported as the crude event rate and estimated using the Kaplan-Meier survival function. Pairwise comparisons of survival rates were made using log-rank test. Multivariable Cox proportional hazards analysis was used to adjust for other established risk factors of recurrence. All statistical analysis was performed using MedCalc (ver ; MedCalc Software, Acacialaan, Ostend, Belgium) and JMP (SAS Institute, Cary, NC, USA). Results Patient Characteristics Patient characteristics at baseline are listed in Table 1. Hypertension was more frequent in group A than group B, and CHADS2 (congestive heart failure, hypertension, advanced age, diabetes mellitus, stroke) score was lower in group B. There were no significant differences, however, between the groups in age, prevalence of PaF, left ventricular ejection fraction, or LA diameter. All PV were successfully isolated in all patients. There were no major procedural Figure 2. Percentage of (A) initial successful pulmonary vein isolation (PVI); (B) spontaneous pulmonary vein (PV) reconnection; and (C) dormant PV conduction in group A vs. group B (control). In group A, the annotation of ablation lesions during PVI was performed using an automated algorithm, while in group B, the annotation of ablation was performed manually by the operator. LPV, left PV; RPV, right PV.

5 1600 TANAKA N et al. were 45/49 (91.8%) in group A and 32/42 in group B (76.2%). The 1-year single procedure success rates and off AADs were 45/49 (91.8%) in group A and 29/42 (69.1%) in group B. On Kaplan-Meier analysis, freedom from recurrent atrial tachyarrhythmia was significantly better in group A (log-rank P=0.0058; Figure 3). Predictors of AF Recurrence After CA To analyze the predictors of AF recurrence, both univariate and multivariate analysis were performed (Table 3). On univariate Cox proportional analysis, ablation without the VisiTag module was significantly associated with AF recurrence (HR, 4.13; 95% CI: ; P=0.0065; Table 3A). The association between ablation without VisiTag and AF recurrence was significant even after adjustment on multivariate Cox proportional analysis for non-paf, LA dimension, age, and female sex. On multivariate analysis, without the VisiTag module was the only independent predictor of AF recurrence (Table 3B). Discussion Major Findings The spontaneous PV reconnection rate was significantly lower in the automated annotation ablation group A than in the control group B. The procedure time was significantly shorter and the 1-year single procedure success rate was significantly better in group A compared with the control group, B. There were no major complications during or after PVI in either group. Significantly, the automated RF ablation algorithm was demonstrated to facilitate the PVI procedure without an increase in adverse complications. Figure 3. Single procedure success rate (A) on/off antiarrhythmic drugs and (B) off anti-arrhythmic drugs vs. use of automated annotation algorithm-guided pulmonary vein isolation: Kaplan-Meier analysis of freedom from recurrent atrial tachyarrhythmia at 1 year. Usefulness of an Automated Annotation System An ablation catheter with the ability to continuously monitor real-time CF has been developed. CF monitoring is useful in AF ablation in reducing ablation time and additional touch-up ablation and in improving the outcome of initial CA compared with conventional irrigated catheters. 16,17 We previously reported that high average CF decreased ablation time but did not improve ablation outcome. 18 A recent randomized multi-center controlled trial also indicomplications in either group (Table 2). PVI Successful PVI at the completion of the initial anatomical line was achieved in the majority of ipsilateral pairs of PV (66%; 65/98) in group A, but in only 31 of 84 (37%) in group B patients, and was more frequently achieved in group A than in group B (P=0.0006; Figure 2A). Spontaneous PV reconnection after waiting >20 min and PV dormant conduction evoked by ATP were observed in only 11 of 49 (22%) and in 9 of 46 (19%) in group A, but in as many as 23 of 42 (55%) and in 16 of 28 (57%) in group B, respectively. These were significantly less frequent in group A than in group B (P= and P=0.0009, respectively; Figure 2B,C). Average CF was higher in group A (P<0.0001); and average procedure time, RF energy application time, and fluoroscopy time were significantly shorter in group A (Table 2). Clinical Recurrence of Arrhythmia A total of 90 out of 91 patients completed 1-year follow up. The 1-year single procedure success rates on or off AADs Importance of Durable Lesion Formation AF recurs after ablation in approximately 10 30% of patients with PaF and in even more patients with persistent AF. 1 This recurrence, however, is associated with the resumption of conduction between the previously isolated PV and LA. 3 5 Reversible tissue injury stems from incomplete lesion formation, resulting in temporary electric uncoupling without cell death. Cappato et al identified conduction recurrence across RF lesions for PV isolation in approximately 80% of cases at 4 months after ablation, and this late reconnection might contribute significantly to AF recurrence. 8,9 A recent study proved the superiority of complete PVI over incomplete PVI with respect to AF recurrence. 10 Methods to detect incomplete reversible lesions in clinical practice remain to be fully clarified. The presence of dormant conduction in response to adenosine or ATP that hyperpolarizes atrial cell membranes and triggers transient conduction, might indicate incomplete cell injury. 11 The efficacy of additional ablation at these sites, however, is still controversial

6 PVI: Guided Novel Annotation 1601 Table 3. Significant Predictors of AF Recurrence After Initial CA A Univariate HR 95% CI Ablation without VisiTag module Female Age (years) Non-PaF Hypertension Diabetes Stroke CHADS2 score LAD LVEF B Multivariate HR 95% CI Model 1 Ablation without VisiTag module Female Model 2 Ablation without VisiTag module Age (years) Model 3 Ablation without VisiTag module Non-PaF Model 4 Ablation without VisiTag module LAD CA, catheter ablation; non-paf, non-paroxysmal AF; PaF, paroxysmal AF. Other abbrviations as in Table 1. cated that the availability of CF data to the operator during an ablation procedure for PAF was not associated with a better 1-year success rate. 7 The failure of CF monitoring to improve clinical outcomes of AF ablation might be due to a lack of information on catheter stability during energy delivery, and heterogeneous RF ablation intensity. If so, real-time information on catheter stability and ablation intensity would possibly improve lesion completeness. The VISITAG module is an automated annotation ablation system that visualizes ablation sites precisely, as well as the intensity of ablation at each ablation point. The tag display influences the operator s manipulation of the catheter, and when settings are optimal, this system might help to achieve more durable PV isolation. 19 Optimal Parameter Setting The tags displayed by the VISITAG module depend on the setting of predefined parameters, and optimal parameter setting is crucial to properly visualize the site and intensity of ablation. We set the ablation tag diameter at 6 mm, catheter stability minimum time at 5 s, and maximum range at 1.5 mm. This means that a new tag will appear if the catheter remains within 1.5 mm for >5 s during the ablation. When we tested a stability maximum range <1.5 mm, new tags appeared one after another, despite maintenance of adequate catheter stability, due mainly to patient breathing. In contrast, with a stability maximum range >1.5 mm, new tags tended to appear at a position that did not overlap the preceding tag when RF was delivered via a dragging technique. Because we aim to overlap the ablation tags as much as possible in order to identify conduction gap loca- tions using ablation tag information, a stability maximum range >1.5 mm is too large. We therefore set the stability maximum range at 1.5 mm. In the force over time category, we set the time at 25% and minimum force at 5 g, meaning that a new tag will appear only if the catheter contact maintains 5 g for >25% of the ablation time. We set the FTI category at gs: as that FTI increases from 100 gs to 150 gs during ablation, the color of the tag gradually changes from white to red. We set the minimal FTI at 150 gs at each ablation site. Efficacy of VISITAG Module In this study, use of the VISITAG module was associated with a lower frequency of conduction gaps after the initial anatomical PVI line, lower rate of spontaneous PV reconnection, and of dormant conduction evoked by ATP infusion. The quality of PVI was clearly better in ablations done using this technology with the present setting than in those without it. This indicates that the VISITAG module is successful in providing the operator with precise data on the location of ablation sites and on the intensity of ablation at each site, with consideration of catheter stability. The ablation procedure was significantly shorter in those cases in which it was used, and from our standpoint also easier than the alternate technique. One-year ablation success rate was better in the VISITAG group, possibly due to improvements in the durability of PVI, as evidenced by the markedly low rate of additional ablation procedures beyond PVI in the present subjects.

7 1602 TANAKA N et al. Previous Studies Previous studies of the efficacy of automated annotation algorithm-guided AF ablation are few in number. 20 Anter et al reported that the automated and objective annotation of RF ablation enhances the detection of ineffective energy delivery and reduces the incidence of conduction recovery. 19 That study did not include a CF category but did include an impedance decrease category. In the present study, average CF was higher in the VisiTag group because the force over time criteria used in the present study meant that the automated tag did not appear until adequate CF was maintained. The use of CF category and FTI might be more effective in achieving transmural lesion during PVI. The EFFICAS I study reported that reconnection in previously isolated PV was strongly correlated with FTI, and suggested a minimal FTI target of 400 gs for each new lesion. 21 Although the present minimum FTI was lower than that in the EFFICAS I study, it is reasonable that minimum FTI was different because the settings of automated annotation and distance between ablation tags were different. In the present study, operators needed to ablate densely to make the ablation tags overlap each other, and the minimum FTI was therefore relatively low. Study Limitations This study had some limitations. First, it was a retrospective observational study, hence there must be some potential bias because a historical control was used for comparison. Second, the recurrence rate of AF may have been underestimated because asymptomatic short-duration AF episodes may have been undetected. Third, the results are based on a relatively small sample of patients. Fourth, this is the report of a single experienced operator. Ensuring the efficacy and safety of automated annotation-based ablation will require confirmation in a prospective study with a larger sample size. Conclusions In PVI procedures, an automated ablation lesion annotation system with optimal settings is a safe and effective way to reduce the acute resumption of LA-PV conduction and to improve AF ablation outcomes, possibly due to the better durability of PVI. Disclosures K. Inoue has received honoraria from Johnson and Johnson KK, Medtronic, Bayer, Boehringer Ingelheim, and Bristol Myers Squibb. The other authors declare no conflict of interest. References 1. Lee G, Sanders P, Kalman JM. Catheter ablation of atrial arrhythmias: State of the art. Lancet 2012; 380: Parkash R, Tang AS, Sapp JL, Wells G. Approach to the catheter ablation technique of paroxysmal and persistent atrial fibrillation: A meta-analysis of the randomized controlled trials. J Cardiovasc Electrophysiol 2011; 22: Verma A, Kilicaslan F, Pisano E, Marrouche NF, Fanelli R, Brachmann J, et al. Response of atrial fibrillation to pulmonary vein antrum isolation is directly related to resumption and delay of pulmonary vein conduction. Circulation 2005; 112: Calkins H, Kuck KH, Cappato R, Brugada J, Camm AJ, Chen SA, et al HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: Recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design. Europace 2012; 14: Ouyang F, Antz M, Ernst S, Hachiya H, Mavrakis H, Deger FT, et al. Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins: Lessons from double lasso technique. Circulation 2005; 111: Kimura M, Sasaki S, Owada S, Horiuchi D, Sasaki K, Itoh T, et al. Comparison of lesion formation between contact force-guided and non-guided circumferential pulmonary vein isolation: A prospective, randomized study. Heart Rhythm 2014; 11: Ullah W, McLean A, Tayebjee MH, Gupta D, Ginks MR, Haywood GA, et al. Randomized trial comparing pulmonary vein isolation using the SmartTouch catheter with or without real-time contact force data. Heart Rhythm 2016; 13: Cappato R, Negroni S, Pecora D, Bentivegna S, Lupo PP, Carolei A, et al. Prospective assessment of late conduction recurrence across radiofrequency lesions producing electrical disconnection at the pulmonary vein ostium in patients with atrial fibrillation. Circulation 2003; 108: Gerstenfeld EP, Callans DJ, Dixit S, Zado E, Marchlinski FE. Incidence and location of focal atrial fibrillation triggers in patients undergoing repeat pulmonary vein isolation. J Cardiovasc Electrophysiol 2003; 14: Kuck KH, Hoffmann BA, Ernst S, Wegscheider K, Treszl A, Metzner A, et al. Impact of complete versus incomplete circumferential lines around the pulmonary veins during catheter ablation of paroxysmal atrial fibrillation: Results from the Gap-Atrial Fibrillation-German Atrial Fibrillation Competence Network 1 Trial. Circ Arrhythm Electrophysiol 2016; 9: e Datino T, Macle L, Qi XY, Maguy A, Comtois P, Chartier D, et al. Mechanisms by which adenosine restores conduction in dormant canine pulmonary veins. Circulation 2010; 121: Yamane T, Matsuo S, Date T, Lellouche N, Hioki M, Narui R, et al. Repeated provocation of time- and ATP-induced early pulmonary vein reconnections after pulmonary vein isolation: Eliminating paroxysmal atrial fibrillation in a single procedure. Circ Arrhythm Electrophysiol 2011; 4: McLellan AJ, Kumar S, Smith C, Morton JB, Kalman JM, Kistler PM. The role of adenosine following pulmonary vein isolation in patients undergoing catheter ablation for atrial fibrillation: A systematic review. J Cardiovasc Electrophysiol 2013; 24: Kobori A, Shizuta S, Inoue K, Kaitani K, Morimoto T, Nakazawa Y, et al. Adenosine triphosphate-guided pulmonary vein isolation for atrial fibrillation: The UNmasking Dormant Electrical Reconduction by Adenosine TriPhosphate (UNDER- ATP) trial. Eur Heart J 2015; 36: Macle L, Khairy P, Weerasooriya R, Novak P, Verma A, Willems S, et al. Adenosine-guided pulmonary vein isolation for the treatment of paroxysmal atrial fibrillation: An international, multicentre, randomised superiority trial. Lancet 2015; 386: Jarman JW, Panikker S, DAS M, Wynn GJ, Ullah W, Kontogeorgis A, et al. Relationship between contact force sensing technology and medium-term outcome of atrial fibrillation ablation: A multicenter study of 600 patients. J Cardiovasc Electrophysiol 2015; 26: Reddy VY, Dukkipati SR, Neuzil P, Natale A, Albenque JP, Kautzner J, et al. Randomized, controlled trial of the safety and effectiveness of a contact force-sensing irrigated catheter for ablation of paroxysmal atrial fibrillation: Results of the TactiCath Contact Force Ablation Catheter Study for Atrial Fibrillation (TOCCASTAR) Study. Circulation 2015; 132: Sotomi Y, Inoue K, Kikkawa T, Tanaka K, Toyoshima Y, Oka T, et al. Clinical impact of contact force and its regional variability on efficiency and effectiveness of pulmonary vein isolation for atrial fibrillation. J Cardiol 2016; 68: Anter E, Tschabrunn CM, Contreras-Valdes FM, Buxton AE, Josephson ME. Radiofrequency ablation annotation algorithm reduces the incidence of linear gaps and reconnection after pulmonary vein isolation. Heart Rhythm 2014; 11: Pedrote A, Arana-Rueda E, Arce-León A, Acosta J, Gómez- Pulido F, Martos-Maine JL, et al. Impact of contact force monitoring in acute pulmonary vein isolation using an anatomic approach: A randomized study. Pacing Clin Electrophysiol 2016; 39: Neuzil P, Reddy VY, Kautzner J, Petru J, Wichterle D, Shah D, et al. Electrical reconnection after pulmonary vein isolation is contingent on contact force during initial treatment: Results from the EFFICAS I study. Circ Arrhythm Electrophysiol 2013; 6:

UNmasking Dormant Electrical Reconduction by Adenosine TriPhosphate

UNmasking Dormant Electrical Reconduction by Adenosine TriPhosphate KPAF trial The Kansai Plus Atrial Fibrillation (KPAF) trial is a 2x2 factorial randomized controlled trial, composed of the UNDER-ATP and EAST-AF trials. Efficacy of adenosine triphosphate guided ablation

More information

Atrial fibrillation (AF), the most sustained cardiac arrhythmia

Atrial fibrillation (AF), the most sustained cardiac arrhythmia Difference Between Dormant Conduction Sites Revealed by Adenosine Triphosphate Provocation and Unipolar Pace-Capture Sites Along the Ablation Line After Pulmonary Vein Isolation Rikitake Kogawa, 1 MD,

More information

Atrial Fibrillation Ablation: in Whom and How

Atrial Fibrillation Ablation: in Whom and How Update on Consensus Statement on Management of Atrial Fibrillation: EHRA 2012 Atrial Fibrillation Ablation: in Whom and How Update of HRS/EHRA AF/ECAS Ablation Document 2012 Anne M Gillis MD FHRS Professor

More information

Raphael Rosso MD, Yuval Levi Med. Eng., Sami Viskin MD Tel Aviv Sourasky Medical Center

Raphael Rosso MD, Yuval Levi Med. Eng., Sami Viskin MD Tel Aviv Sourasky Medical Center Radiofrequency Ablation of Atrial Fibrillation: Comparison of Success Rate of Circular Ablation vs Point-by-Point Ablation with Contact Force Assessment in Paroxysmal and Persistent Atrial Fibrillation

More information

Catheter ablation is a well-established treatment for

Catheter ablation is a well-established treatment for 548 TANAKA N et al. Circulation Journal ORIGINAL ARTICLE Circ J 2019; 83: 548 555 doi: 10.1253/circj.CJ-18-1035 Arrhythmia/Electrophysiology Comparison of the Safety and Efficacy of Automated Annotation-Guided

More information

Catheter ablation of atrial fibrillation: Indications and tools for improvement of the success rate of the method. Konstantinos P.

Catheter ablation of atrial fibrillation: Indications and tools for improvement of the success rate of the method. Konstantinos P. Ioannina 2015 Catheter ablation of atrial fibrillation: Indications and tools for improvement of the success rate of the method Konstantinos P. Letsas, MD, FESC SECOND DEPARTMENT OF CARDIOLOGY LABORATORY

More information

Time to recurrence of atrial fibrillation influences outcome following catheter ablation

Time to recurrence of atrial fibrillation influences outcome following catheter ablation Time to recurrence of atrial fibrillation influences outcome following catheter ablation Larraitz Gaztañaga, MD, David S. Frankel, MD, Maria Kohari, MD, Lavanya Kondapalli, MD, Erica S. Zado, PA-C, FHRS,

More information

480 April 2004 PACE, Vol. 27

480 April 2004 PACE, Vol. 27 Incremental Value of Isolating the Right Inferior Pulmonary Vein During Pulmonary Vein Isolation Procedures in Patients With Paroxysmal Atrial Fibrillation HAKAN ORAL, AMAN CHUGH, CHRISTOPH SCHARF, BURR

More information

Catheter Ablation of Atrial Fibrillation Strategy and Outcome Predictors Shih-Ann Chen MD

Catheter Ablation of Atrial Fibrillation Strategy and Outcome Predictors Shih-Ann Chen MD Catheter Ablation of Atrial Fibrillation Strategy and Outcome Predictors Shih-Ann Chen MD Taipei Veterans General Hospital, Taiwan Outline of AF Ablation 1. Strategy for Catheter Ablation of AF 2. Substrate

More information

Integration of CT and fluoroscopy images in the ablative treatment of atrial fibrillation

Integration of CT and fluoroscopy images in the ablative treatment of atrial fibrillation Clinical applications Integration of CT and fluoroscopy images in the ablative treatment of atrial fibrillation C. Kriatselis M. Tang M. Roser J-H. erds-li E. leck Department of Internal Medicine/Cardiology,

More information

Mapping and Ablation in AF: how can we evaluate the lesion formation?

Mapping and Ablation in AF: how can we evaluate the lesion formation? Innovative Cardiac Arrhythmias solutions in only one technology Venice Arrhythmias 17 Oct 2015 Mapping and Ablation in AF: how can we evaluate the lesion formation? Dhiraj Gupta MD DM FRCP Consultant Cardiologist

More information

Long Standing Persistent AF ; CPVI is enough for it

Long Standing Persistent AF ; CPVI is enough for it Long Standing Persistent AF ; CPVI is enough for it Kee-Joon Choi, MD University of Ulsan College of Medicine Asan Medical Center, Seoul, Korea Boston AF Symposium 2012 In a patient undergoing AF ablation

More information

Since pulmonary veins (PVs) have

Since pulmonary veins (PVs) have Case Report Hellenic J Cardiol 2011; 52: 371-376 Left Atrial-Pulmonary Vein Reentrant Tachycardia Following Pulmonary Vein Isolation Dionyssios Leftheriotis, Feifan Ouyang, Karl-Heinz Kuck II. Med. Abteilung,

More information

Catheter Ablation of Atrial Fibrillation in Patients with Prosthetic Mitral Valve

Catheter Ablation of Atrial Fibrillation in Patients with Prosthetic Mitral Valve Catheter Ablation of Atrial Fibrillation in Patients with Prosthetic Mitral Valve Luigi Di Biase, MD, PhD, FHRS Senior Researcher Texas Cardiac Arrhythmia Institute at St. David s Medical Center, Austin,

More information

Catheter Ablation of Long-Standing Persistent Atrial Fibrillation

Catheter Ablation of Long-Standing Persistent Atrial Fibrillation Journal of the American College of Cardiology Vol. 60, No. 19, 2012 2012 by the American College of Cardiology Foundation ISSN 0735-1097/$36.00 Published by Elsevier Inc. http://dx.doi.org/10.1016/j.jacc.2012.04.060

More information

Percutaneous Transvenous Atrial Fibrillation Ablation and Stroke

Percutaneous Transvenous Atrial Fibrillation Ablation and Stroke Percutaneous Transvenous Atrial Fibrillation Ablation and Stroke Vivek Y. Reddy, MD Helmsley Trust Professor of Medicine Director, Cardiac Arrhythmia Service The Mount Sinai Hospital Disclosures Grant

More information

Six-Year Follow-up of Catheter Ablation in Paroxysmal Atrial Fibrillation

Six-Year Follow-up of Catheter Ablation in Paroxysmal Atrial Fibrillation 2722 UCHIYAMA T et al. Circulation Journal ORIGINAL ARTICLE Official Journal of the Japanese Circulation Society http://www.j-circ.or.jp Arrhythmia/Electrophysiology Six-Year Follow-up of Catheter Ablation

More information

Κατάλυση παροξυσμικής κολπικής μαρμαρυγής Ποια τεχνολογία και σε ποιους ασθενείς; Χάρης Κοσσυβάκης Καρδιολογικό Τμήμα Γ.Ν.Α. «Γ.

Κατάλυση παροξυσμικής κολπικής μαρμαρυγής Ποια τεχνολογία και σε ποιους ασθενείς; Χάρης Κοσσυβάκης Καρδιολογικό Τμήμα Γ.Ν.Α. «Γ. Κατάλυση παροξυσμικής κολπικής μαρμαρυγής Ποια τεχνολογία και σε ποιους ασθενείς; Χάρης Κοσσυβάκης Καρδιολογικό Τμήμα Γ.Ν.Α. «Γ. ΓΕΝΝΗΜΑΤΑΣ» Rhythm control antiarrhythmic drugs vs catheter ablation Summary

More information

A Cryo Anatomical Procedure to Everyone? Saverio Iacopino, FACC, FESC

A Cryo Anatomical Procedure to Everyone? Saverio Iacopino, FACC, FESC A Cryo Anatomical Procedure to Everyone? Saverio Iacopino, FACC, FESC AF Clinical/Referral Challenge Asymptomatic 40% 3 Rx Effective 30% Failed Rx Ablation Atrial fibrillation (AF) is the most common Candidate

More information

New Parameter to Predict Recurrence of Paroxysmal Atrial Fibrillation after Pulmonary Vein Isolation by the P-Wave Signal-Averaged Electrocardiogram

New Parameter to Predict Recurrence of Paroxysmal Atrial Fibrillation after Pulmonary Vein Isolation by the P-Wave Signal-Averaged Electrocardiogram Showa Univ J Med Sci 29 2, 141 150, June 2017 Original New Parameter to Predict Recurrence of Paroxysmal Atrial Fibrillation after Pulmonary Vein Isolation by the P-Wave Signal-Averaged Electrocardiogram

More information

Ablation Index : A new standard for Safety and Efficacy. Dr Franck Halimi Hôpital Privé Parly 2 Le Chesnay, France

Ablation Index : A new standard for Safety and Efficacy. Dr Franck Halimi Hôpital Privé Parly 2 Le Chesnay, France Ablation Index : A new standard for Safety and Efficacy Dr Franck Halimi Hôpital Privé Parly 2 Le Chesnay, France Disclosures Dr Franck Halimi... I have the following potential conflicts of interest to

More information

The pulmonary veins have been demonstrated to often

The pulmonary veins have been demonstrated to often Pulmonary Vein Isolation for Paroxysmal and Persistent Atrial Fibrillation Hakan Oral, MD; Bradley P. Knight, MD; Hiroshi Tada, MD; Mehmet Özaydın, MD; Aman Chugh, MD; Sohail Hassan, MD; Christoph Scharf,

More information

Atrial Fibrillation: Catheter Ablation with New Technologies, Improving Quality of Life and Outcomes in Various Disease States

Atrial Fibrillation: Catheter Ablation with New Technologies, Improving Quality of Life and Outcomes in Various Disease States Atrial Fibrillation: Catheter Ablation with New Technologies, Improving Quality of Life and Outcomes in Various Disease States Srinivas R. Dukkipati, MD Co-Director, Cardiac Arrhythmia Service The Mount

More information

Stand alone maze: when and how?

Stand alone maze: when and how? Stand alone maze: when and how? Dong Seop Jeong Department of Thoracic and Cardiovascular Surgery, HVSI Samsung Medical Center Type of atrial fibrillation First diagnose AF Paroxysmal AF: self-terminating

More information

Role of LAA isolation in AF cure

Role of LAA isolation in AF cure MAM 2017, Zurich Role of LAA isolation in AF cure Sakis Themistoclakis, MD Director, Unit of Electrophysiology and Cardiac Pacing Department of Cardiothoracic & Vascular Medicine Ospedale dell Angelo,

More information

New technology to minimize radiation

New technology to minimize radiation Room 103-104 15/April/2016 New technology to minimize radiation Jun Kim University of Ulsan College of Medicine Asan Medical Center Heart Institute Disclosure NONE I have no experience using Carto Univu

More information

AF ABLATION Concepts and Techniques

AF ABLATION Concepts and Techniques AF ABLATION Concepts and Techniques Antony F Chu, M.D. Director of Complex Ablation Arrhythmia Services Section Division of Cardiology at the Rhode Island and Miriam Hospital HIGHLIGHTS The main indications

More information

Characteristics of Rapid Rhythms Recorded Within Pulmonary Veins During Atrial Fibrillation

Characteristics of Rapid Rhythms Recorded Within Pulmonary Veins During Atrial Fibrillation Characteristics of Rapid Rhythms Recorded Within Pulmonary Veins During Atrial Fibrillation HIROSHI TADA, MEHMET ÖZAYDIN, HAKAN ORAL, BRADLEY P. KNIGHT, AMAN CHUGH, CHRISTOPH SCHARF, FRANK PELOSI, Jr.,

More information

Impact of Atrial Fibrillation Termination Site and Termination Mode in Catheter Ablation on Arrhythmia Recurrence

Impact of Atrial Fibrillation Termination Site and Termination Mode in Catheter Ablation on Arrhythmia Recurrence 78 MIYAZAKI S et al. Circulation Journal ORIGINAL ARTICLE Official Journal of the Japanese Circulation Society http://www.j-circ.or.jp Arrhythmia/Electrophysiology Impact of Atrial Fibrillation Termination

More information

Supplementary Online Content

Supplementary Online Content Supplementary Online Content Verma A, Champagne J, Sapp J, et al. Asymptomatic episodes of atrial fibrillation before and after catheter ablation: a prospective, multicenter study. JAMA Intern Med. Published

More information

Interventional solutions for atrial fibrillation in patients with heart failure

Interventional solutions for atrial fibrillation in patients with heart failure Interventional solutions for atrial fibrillation in patients with heart failure Advances in Cardiovascular Arrhythmias Great Innovations in Cardiology Matteo Anselmino, MD PhD Division of Cardiology Department

More information

2017 HRS/EHRA/ECAS/APHRS/SOLAECE Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation

2017 HRS/EHRA/ECAS/APHRS/SOLAECE Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation Summary of Expert Consensus Statement for CLINICIANS 2017 HRS/EHRA/ECAS/APHRS/SOLAECE Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation This is a summary of the Heart

More information

PVI and What Else for Persistent AF Lessons Learned from STAR AF 2 CCCEP 2015 October 31, New York

PVI and What Else for Persistent AF Lessons Learned from STAR AF 2 CCCEP 2015 October 31, New York PVI and What Else for Persistent AF Lessons Learned from STAR AF 2 CCCEP 2015 October 31, New York Atul Verma, MD FRCPC FHRS Director, Arrhythmia Services Southlake Regional Health Centre Faculty of Medicine

More information

INTRODUCTION. Key Words:

INTRODUCTION. Key Words: Original Article Acta Cardiol Sin 2015;31:317 324 doi: 10.6515/ACS20141218A EPS and Arrhythmia The Electrical Characteristics and Clinical Significance of the Effect of Adenosine on Dissociated Activity

More information

What s new in my specialty?

What s new in my specialty? What s new in my specialty? Jon Melman, MD Heart Rhythm Specialists McKay-Dee Hospital some would say some would say my specialty 1 some would say my specialty First pacemaker 1958 some would say my specialty

More information

Mechanism of Immediate Recurrences of Atrial Fibrillation After Restoration of Sinus Rhythm

Mechanism of Immediate Recurrences of Atrial Fibrillation After Restoration of Sinus Rhythm Mechanism of Immediate Recurrences of Atrial Fibrillation After Restoration of Sinus Rhythm AMAN CHUGH, MEHMET OZAYDIN, CHRISTOPH SCHARF, STEVE W.K. LAI, BURR HALL, PETER CHEUNG, FRANK PELOSI, JR, BRADLEY

More information

Comparative Effectiveness of Radiofrequency Catheter Ablation for Atrial Fibrillation Executive Summary

Comparative Effectiveness of Radiofrequency Catheter Ablation for Atrial Fibrillation Executive Summary Number 15 Effective Health Care Comparative Effectiveness of Radiofrequency Catheter Ablation for Atrial Fibrillation Executive Summary Background The Agency for Healthcare Research and Quality commissioned

More information

Clinical Value of Noninducibility by High-Dose Isoproterenol Versus Rapid Atrial Pacing After Catheter Ablation of Paroxysmal Atrial Fibrillation

Clinical Value of Noninducibility by High-Dose Isoproterenol Versus Rapid Atrial Pacing After Catheter Ablation of Paroxysmal Atrial Fibrillation 13 Clinical Value of Noninducibility by High-Dose Isoproterenol Versus Rapid Atrial Pacing After Catheter Ablation of Paroxysmal Atrial Fibrillation THOMAS CRAWFORD, M.D., AMAN CHUGH, M.D., ERIC GOOD,

More information

Linear Ablation Should Not Be a Standard Part of Ablation in Persistent AF. Disclosures. LA Ablation vs. Segmental Ostial Ablation With PVI for PAF

Linear Ablation Should Not Be a Standard Part of Ablation in Persistent AF. Disclosures. LA Ablation vs. Segmental Ostial Ablation With PVI for PAF Linear Ablation Should Not Be a Standard Part of Ablation in Persistent AF The CA Heart Rhythm Symposium September 7, 2012 Gregory K. Feld, MD Professor of Medicine Director, Cardiac EP Program University

More information

Catheter ablation of AF Where do we stand, where do we go?

Catheter ablation of AF Where do we stand, where do we go? Catheter ablation of AF Where do we stand, where do we go? Sébastien Knecht MD, PhD Hôpital cardiologique du Haut L Evêque, Bordeaux Declaration of conflict of interest ABLATION STRATEGIES Duration proc:

More information

Invasive and Medical Treatments for Atrial Fibrillation. Thomas J Dresing, MD Section of Electrophysiology and Pacing Cleveland Clinic

Invasive and Medical Treatments for Atrial Fibrillation. Thomas J Dresing, MD Section of Electrophysiology and Pacing Cleveland Clinic Invasive and Medical Treatments for Thomas J Dresing, MD Section of Electrophysiology and Pacing Cleveland Clinic Disclosures Fellow s advisory panel for St Jude Medical Speaking honoraria from: Boston

More information

In Whom and When Should Atrial Fibrillation Ablation be Considered?

In Whom and When Should Atrial Fibrillation Ablation be Considered? In Whom and When Should Atrial Fibrillation Ablation be Considered? Christian de Chillou, MD, PhD Department of Cardiology University Hospital Nancy, France ESC 2010 Stockholm, August 30. 2010 2 In Whom?

More information

Electrophysiological Characteristics of Atrial Tachycardia After Pulmonary Vein Isolation of Atrial Fibrillation

Electrophysiological Characteristics of Atrial Tachycardia After Pulmonary Vein Isolation of Atrial Fibrillation Circulation Journal Official Journal of the Japanese Circulation Society http://www.j-circ.or.jp Advance Publication by J-STAGE REVIEW Electrophysiological Characteristics of Atrial Tachycardia After Pulmonary

More information

Ruolo della ablazione della fibrillazione atriale nello scompenso cardiaco

Ruolo della ablazione della fibrillazione atriale nello scompenso cardiaco Ruolo della ablazione della fibrillazione atriale nello scompenso cardiaco Matteo Anselmino Division of Cardiology Città della Salute e della Scienza Hospital University of Turin, Italy Disclosure: Honoraria

More information

Combined catheter ablation and left atrial appendage closure as a. treatment of atrial fibrillation

Combined catheter ablation and left atrial appendage closure as a. treatment of atrial fibrillation Combined catheter ablation and left atrial appendage closure as a hybrid procedure for the treatment of atrial fibrillation Giulio Molon, MD FACC, FESC, Fellow ANMCO Card Dept, S.Cuore hospital Negrar

More information

Catheter Ablation of Atrial Fibrillation

Catheter Ablation of Atrial Fibrillation Cardiology Update 2011 Catheter Ablation of Atrial Fibrillation Laurent Haegeli University Hospital Zurich February 16, 2011 Willem Einthoven and Sir Thomas Lewis The first ECG in 1903 Willem Einthoven

More information

AF :RHYTHM CONTROL BY DR-MOHAMMED SALAH ASSISSTANT LECTURER CARDIOLOGY DEPARTMENT

AF :RHYTHM CONTROL BY DR-MOHAMMED SALAH ASSISSTANT LECTURER CARDIOLOGY DEPARTMENT AF :RHYTHM CONTROL BY DR-MOHAMMED SALAH ASSISSTANT LECTURER CARDIOLOGY DEPARTMENT 5-2014 Atrial Fibrillation therapeutic Approach Rhythm Control Thromboembolism Prevention: Recommendations Direct-Current

More information

University of Groningen. Ablation of atrial fibrillation de Maat, Gijs Eduard

University of Groningen. Ablation of atrial fibrillation de Maat, Gijs Eduard University of Groningen Ablation of atrial fibrillation de Maat, Gijs Eduard IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from it. Please check

More information

ESSA HEART AND VASCULAR INSTITUTE APR/MAY/JUNE 2009 CLINICAL LETTER

ESSA HEART AND VASCULAR INSTITUTE APR/MAY/JUNE 2009 CLINICAL LETTER CLINICAL LETTER Exciting things are happening at the ESSA Heart and Vascular Institute and the Pocono Medical Center! We are all proud of the stellar team of professionals who are working very hard to

More information

Is cardioversion old hat? What is new in interventional treatment of AF symptoms?

Is cardioversion old hat? What is new in interventional treatment of AF symptoms? Is cardioversion old hat? What is new in interventional treatment of AF symptoms? Joseph de Bono Consultant Electrophysiologist University Hospitals Birmingham Atrial Fibrillation (AF) Affects 2% of the

More information

Electrical isolation of the pulmonary veins (PVs) to treat

Electrical isolation of the pulmonary veins (PVs) to treat Mechanisms of Organized Left Atrial Tachycardias Occurring After Pulmonary Vein Isolation Edward P. Gerstenfeld, MD; David J. Callans, MD; Sanjay Dixit, MD; Andrea M. Russo, MD; Hemal Nayak, MD; David

More information

AF ablation Penn experience. Optimal approach to the ablation of PAF: Importance of identifying triggers 9/25/2009

AF ablation Penn experience. Optimal approach to the ablation of PAF: Importance of identifying triggers 9/25/2009 Optimal approach to the ablation of PAF: Importance of identifying triggers David J. Callans, MD University of Pennsylvania School of Medicine AF ablation Penn experience Antral (circumferential) PV ablation

More information

Peri-Mitral Atrial Flutter with Partial Conduction Block between Left Atrium and Coronary Sinus

Peri-Mitral Atrial Flutter with Partial Conduction Block between Left Atrium and Coronary Sinus Accepted Manuscript Peri-Mitral Atrial Flutter with Partial Conduction Block between Left Atrium and Coronary Sinus Ryota Isogai, MD, Seiichiro Matsuo, MD, Ryohsuke Narui, MD, Shingo Seki, MD;, Michihiro

More information

Nationwide Survey of Catheter Ablation for Atrial Fibrillation: The Japanese Catheter Ablation Registry of Atrial Fibrillation (J-CARAF)

Nationwide Survey of Catheter Ablation for Atrial Fibrillation: The Japanese Catheter Ablation Registry of Atrial Fibrillation (J-CARAF) Circulation Journal Official Journal of the Japanese Circulation Society http://www.j-circ.or.jp LATE BREAKING COHORT STUDIES (JCS 2014) Nationwide Survey of Catheter Ablation for Atrial Fibrillation:

More information

Original Article Pulmonary vein isolation without left atrial mapping

Original Article Pulmonary vein isolation without left atrial mapping www.ipej.org 142 Original Article Pulmonary vein isolation without left atrial mapping Attila Kardos MD 1, Csaba Foldesi MD 1, Karoly Ladunga MSc, PhD 1, Attila Toth MD 2, Tamas Szili-Torok MD, PhD 1 1

More information

Catheter ablation of atrial macro re-entrant Tachycardia - How to use 3D entrainment mapping -

Catheter ablation of atrial macro re-entrant Tachycardia - How to use 3D entrainment mapping - Catheter ablation of atrial macro re-entrant Tachycardia - How to use 3D entrainment mapping - M. Esato, Y. Chun, G. Hindricks Kyoto Ijinkai Takeda Hosptial, Department of Arrhythmia, Japan Kyoto Koseikai

More information

Catheter Ablation: Atrial fibrillation (AF) is the most common. Another Option for AF FAQ. Who performs ablation for treatment of AF?

Catheter Ablation: Atrial fibrillation (AF) is the most common. Another Option for AF FAQ. Who performs ablation for treatment of AF? : Another Option for AF Atrial fibrillation (AF) is a highly common cardiac arrhythmia and a major risk factor for stroke. In this article, Dr. Khan and Dr. Skanes detail how catheter ablation significantly

More information

Outcomes of AF Ablation

Outcomes of AF Ablation 2017 춘계심혈관통합학술대회 AF Summit: Atrial Fibrillation Apr.21(Fri) 14:40-16:10 Rm.300B 15:00-15:10 Outcomes of AF Ablation Gi-Byoung Nam MD Asan Medical Center, UUCM 2017 Annual Spring Scientific Conference of

More information

20% 10/9/2018. Fluoroless Ablation relinquishing an old habit. Prevalence of Atrial Fibrillation. Atrial Fibrillation is a Progressive Disease

20% 10/9/2018. Fluoroless Ablation relinquishing an old habit. Prevalence of Atrial Fibrillation. Atrial Fibrillation is a Progressive Disease Fluoroless Ablation relinquishing an old habit Robert Percell, MD, FACC Cardiac Electrophysiologist, Bryan Heart Institute Lincoln, NE Prevalence of Atrial Fibrillation 3.1 Million + 1 Million by 2020

More information

Catheter Ablation for Atrial Fibrillation: Patient Selection and Outcomes

Catheter Ablation for Atrial Fibrillation: Patient Selection and Outcomes Catheter Ablation for Atrial Fibrillation: Patient Selection and Outcomes Francis Marchlinski, MD Richard T and Angela Clark President s Distinguished Professor Director Cardiac Electrophysiolgy University

More information

PRIMARY RESULTS OF RF CATHETER ABLATION FOR AF IN VIETNAM HEART INSTITUTE. PHAM QUOC KHANH, MD, PhD. et al Vietnam Heart Institute

PRIMARY RESULTS OF RF CATHETER ABLATION FOR AF IN VIETNAM HEART INSTITUTE. PHAM QUOC KHANH, MD, PhD. et al Vietnam Heart Institute PRIMARY RESULTS OF RF CATHETER ABLATION FOR AF IN VIETNAM HEART INSTITUTE PHAM QUOC KHANH, MD, PhD. et al Vietnam Heart Institute Background - Forms of Atrial Fibrillation - Clinical type of AF: + paroxysmal

More information

Pulmonary Vein Isolation for AF RF or Cryo? Dr. Yuen Ho Chuen Princess Margaret Hospital

Pulmonary Vein Isolation for AF RF or Cryo? Dr. Yuen Ho Chuen Princess Margaret Hospital Pulmonary Vein Isolation for AF RF or Cryo? Dr. Yuen Ho Chuen Princess Margaret Hospital PV as a Source of Ectopic Activity Haissaguerre, et al. NEJM 1998 RF Ablation Gold standard Point by point ablation

More information

Introduction. CLINICAL RESEARCH Ablation for atrial fibrillation

Introduction. CLINICAL RESEARCH Ablation for atrial fibrillation Europace (2016) 18, 71 77 doi:10.1093/europace/euv224 CLINICAL RESEARCH Ablation for atrial fibrillation Electrophysiological findings following pulmonary vein isolation using radiofrequency catheter guided

More information

Επιπλοκές κατάλυσης πνευµονικών φλεβών

Επιπλοκές κατάλυσης πνευµονικών φλεβών Επιπλοκές κατάλυσης πνευµονικών φλεβών Παναγιώτης Ιωαννίδης Διευθυντής Τµήµατος Αρρυθµιών & Επεµβατικής Ηλεκτροφυσιολογίας Βιοκλινικής Αθηνών ΣΕΜΙΝΑΡΙΑ ΟΜΑΔΩΝ ΕΡΓΑΣΙΑΣ Ιωάννινα, 27-2-2015 Solving an equation

More information

Atrial fibrillation, Sick sinus syndrome, Sinus pause, Pulmonary vein isola- tion

Atrial fibrillation, Sick sinus syndrome, Sinus pause, Pulmonary vein isola- tion Case Reports Pulmonary Vein Isolation for Atrial Fibrillation in Patients With Paroxysmal Atrial Fibrillation and Prolonged Sinus Pause Kimie OHKUBO, 1 MD, Ichiro WATANABE, 1 MD, Yasuo OKUMURA, 1 MD, Sonoko

More information

Thetimecourseofexitandentranceblockduring cryoballoon pulmonary vein isolation

Thetimecourseofexitandentranceblockduring cryoballoon pulmonary vein isolation Europace (2014) 16, 500 504 doi:10.1093/europace/eut231 CLINICAL RESEARCH Ablation for atrial fibrillation Thetimecourseofexitandentranceblockduring cryoballoon pulmonary vein isolation Jason Andrade 1,2

More information

Ablation Should Not Be Used as Primary Therapy for Treatment of Patients with Atrial Fibrillation

Ablation Should Not Be Used as Primary Therapy for Treatment of Patients with Atrial Fibrillation Ablation Should Not Be Used as Primary Therapy for Treatment of Patients with Atrial Fibrillation 25 October 2008 Update in Electrocardiography and Arrhythmias Zian H. Tseng, M.D., M.A.S. Assistant Professor

More information

Atrial ectopic beats within the pulmonary veins (PVs) are

Atrial ectopic beats within the pulmonary veins (PVs) are Phased-Array Intracardiac Echocardiography Monitoring During Pulmonary Vein Isolation in Patients With Atrial Fibrillation Impact on Outcome and Complications Nassir F. Marrouche, MD; David O. Martin,

More information

Long-Term Outcomes After Cryoballoon Pulmonary Vein Isolation

Long-Term Outcomes After Cryoballoon Pulmonary Vein Isolation Journal of the American College of Cardiology Vol. 61, No. 16, 2013 2013 by the American College of Cardiology Foundation ISSN 0735-1097/$36.00 Published by Elsevier Inc. http://dx.doi.org/10.1016/j.jacc.2012.09.033

More information

The Emerging Atrial Fibrillation Epidemic: Treat It, Leave It or Burn It. Chandra Kumbar MD FACC FHRS The Heart Group, Evansville IN

The Emerging Atrial Fibrillation Epidemic: Treat It, Leave It or Burn It. Chandra Kumbar MD FACC FHRS The Heart Group, Evansville IN The Emerging Atrial Fibrillation Epidemic: Treat It, Leave It or Burn It Chandra Kumbar MD FACC FHRS The Heart Group, Evansville IN Disclosures Consultant Advisory Board, Medtronic Atrial fibrillation

More information

8/16/2016. Disclosures. Is Uninterrupted OAC Standard of Care for AF Ablation? CHRS 2016, San Francisco. Risk of Stroke Peri-Ablation

8/16/2016. Disclosures. Is Uninterrupted OAC Standard of Care for AF Ablation? CHRS 2016, San Francisco. Risk of Stroke Peri-Ablation Disclosures Is Uninterrupted OAC Standard of Care for AF Ablation? CHRS 2016, San Francisco Atul Verma, MD FRCPC FHRS Director, Heart Rhythm Program Southlake Regional Health Centre Newmarket, Ontario,

More information

Debate-STAR AF 2 study. PVI is not enough

Debate-STAR AF 2 study. PVI is not enough Debate-STAR AF 2 study PVI is not enough Debate about STAR AF 2 trial STAR AF trial Substrate and Trigger Ablation for Reduction of Atrial Fibrillation EHJ 2010 STAR-AF 2 trial One Size Fits All? PVI is

More information

Contemporary Strategies for Catheter Ablation of Atrial Fibrillation

Contemporary Strategies for Catheter Ablation of Atrial Fibrillation Contemporary Strategies for Catheter Ablation of Atrial Fibrillation Suneet Mittal, MD Director, Electrophysiology Medical Director, Snyder Center for Atrial Fibrillation The Arrhythmia Institute at The

More information

Catheter ablation (CA) is being increasingly used for

Catheter ablation (CA) is being increasingly used for Circ J doi: 10.1253/circj.CJ-17-1213 Advance Publication by-j-stage ORIGINAL ARTICLE Arrhythmia/Electrophysiology Efficacy and Safety of Figure-of-Eight Suture for Hemostasis After Radiofrequency Catheter

More information

The major thoracic veins, with their specific electrical

The major thoracic veins, with their specific electrical Atrial Fibrillation Originating From Persistent Left Superior Vena Cava Li-Fern Hsu, MBBS; Pierre Jaïs, MD; David Keane, MD; J. Marcus Wharton, MD; Isabel Deisenhofer, MD; Mélèze Hocini, MD; Dipen C. Shah,

More information

Original. Key words : atrial fibrillation, pulmonary vein isolation, external loop recorder. Introduction

Original. Key words : atrial fibrillation, pulmonary vein isolation, external loop recorder. Introduction Showa Univ J Med Sci 26 2, 109 119, June 2014 Original Recurrence of Atrial Fibrillation within Three Months after Pulmonary Vein Isolation in Patients with Paroxysmal Atrial Fibrillation : Analysis Using

More information

The influence of varying energy settings on efficacy and safety of endoscopic pulmonary vein isolation

The influence of varying energy settings on efficacy and safety of endoscopic pulmonary vein isolation The influence of varying energy settings on efficacy and safety of endoscopic pulmonary vein isolation Andreas Metzner, MD,* Erik Wissner, MD, FHRS,* Bas Schoonderwoerd, MD,* Andre Burchard, MD, Roland

More information

AF Ablation in 2015 Why, Who, What and How? Steve Wilton ACC Rockies, Banff March 10, 2015

AF Ablation in 2015 Why, Who, What and How? Steve Wilton ACC Rockies, Banff March 10, 2015 AF Ablation in 2015 Why, Who, What and How? Steve Wilton ACC Rockies, Banff March 10, 2015 Disclosures Research grant: St. Jude medical Speaking: Boehringer-Ingelheim Consulting: Arca Biopharma Learning

More information

974 ZUCCHELLI G et al. Circ J 2018; 82: ORIGINAL ARTICLE doi: /circj.CJ

974 ZUCCHELLI G et al. Circ J 2018; 82: ORIGINAL ARTICLE doi: /circj.CJ 974 ZUCCHELLI G et al. Circ J 2018; 82: 974 982 ORIGINAL ARTICLE doi: 10.1253/circj.CJ-17-0421 Arrhythmia/Electrophysiology Contiguity Between Ablation Lesions and Strict Catheter Stability Settings Assessed

More information

Pulmonary vein isolation (PVI) is

Pulmonary vein isolation (PVI) is Case Report Hellenic J Cardiol 2012; 53: 163-167 The Use of the Multi-Electrode Duty-Cycled Radiofrequency Ablation Catheter PVAC for the Ablation of a Left Atrial Tachycardia Dionyssios Leftheriotis 1,

More information

Electrical and Mechanical Insights of Human Atrial Fibrillation. Sághy László, MD. Summary of PhD Thesis

Electrical and Mechanical Insights of Human Atrial Fibrillation. Sághy László, MD. Summary of PhD Thesis Electrical and Mechanical Insights of Human Atrial Fibrillation Sághy László, MD Summary of PhD Thesis Second Department of Medicine and Cardiology Center, University of Szeged Szeged 2012 Introduction

More information

How to Distinguish Focal Atrial Tachycardia from Small Circuits and Reentry

How to Distinguish Focal Atrial Tachycardia from Small Circuits and Reentry How to Distinguish Focal Atrial Tachycardia from Small Circuits and Reentry Pierre Jaïs; Bordeaux, France IHU LIRYC ANR-10-IAHU-04 Equipex MUSIC imaging platform ANR-11-EQPX-0030 Eutraf HEALTH-F2-2010-261057

More information

AF Today: W. For the majority of patients with atrial. are the Options? Chris Case

AF Today: W. For the majority of patients with atrial. are the Options? Chris Case AF Today: W hat are the Options? Management strategies for patients with atrial fibrillation should depend on the individual patient. Treatment with medications seems adequate for most patients with atrial

More information

Indicatie voor ablatie bij voorkamerfibrillatie. Andrea Sarkozy Cardiologie Universitair Ziekenhuis Antwerpen

Indicatie voor ablatie bij voorkamerfibrillatie. Andrea Sarkozy Cardiologie Universitair Ziekenhuis Antwerpen Indicatie voor ablatie bij voorkamerfibrillatie Andrea Sarkozy Cardiologie Universitair Ziekenhuis Antwerpen Definition and Classification of AF - Practical aspects Classification of AF Paroxysmal, persistent,

More information

Topographic Distribution of Focal Left Atrial Tachycardias Defined by Electrocardiographic and Electrophysiological Data

Topographic Distribution of Focal Left Atrial Tachycardias Defined by Electrocardiographic and Electrophysiological Data Circ J 2005; 69: 205 210 Topographic Distribution of Focal Left Atrial Tachycardias Defined by Electrocardiographic and Electrophysiological Data Hitoshi Hachiya, MD; Sabine Ernst, MD; Feifan Ouyang, MD;

More information

Effect of Left Atrial Ablation on the Quality of Life in Patients With Atrial Fibrillation

Effect of Left Atrial Ablation on the Quality of Life in Patients With Atrial Fibrillation Circ J 08; 72: 582 587 Effect of Left Atrial Ablation on the Quality of Life in Patients With Atrial Fibrillation Shinsuke Miyazaki, MD; Taishi Kuwahara, MD; Atsushi Takahashi, MD; Atsushi Kobori, MD;

More information

ΚΑΤΑΛΥΣΗ ΚΟΛΠΙΚΗΣ ΜΑΡΜΑΡΥΓΗΣ. ΥΠΕΡ. Michalis Efremidis MD Second Department of Cardiology Evangelismos General Hospital

ΚΑΤΑΛΥΣΗ ΚΟΛΠΙΚΗΣ ΜΑΡΜΑΡΥΓΗΣ. ΥΠΕΡ. Michalis Efremidis MD Second Department of Cardiology Evangelismos General Hospital ΚΑΤΑΛΥΣΗ ΚΟΛΠΙΚΗΣ ΜΑΡΜΑΡΥΓΗΣ. ΥΠΕΡ. Michalis Efremidis MD Second Department of Cardiology Evangelismos General Hospital Rate control versus Rhythm control for Atrial Fibrillation AFFIRM N Engl J Med 2002;347:1825-33

More information

Impact of type of atrial fibrillation and repeat catheter ablation on long-term freedom from atrial fibrillation: Results from a multicenter study

Impact of type of atrial fibrillation and repeat catheter ablation on long-term freedom from atrial fibrillation: Results from a multicenter study Impact of type of atrial fibrillation and repeat catheter ablation on long-term freedom from atrial fibrillation: Results from a multicenter study Mandeep Bhargava, MD,* Luigi Di Biase, MD,* Prasant Mohanty,

More information

Role of Extended External Auto-Triggered Loop Recorder Monitoring for Atrial Fibrillation

Role of Extended External Auto-Triggered Loop Recorder Monitoring for Atrial Fibrillation Circulation Journal Official Journal of the Japanese Circulation Society http://www.j-circ.or.jp ORIGINAL ARTICLE Arrhythmia/Electrophysiology Role of Extended External Auto-Triggered Loop Recorder Monitoring

More information

Evidence for Longitudinal and Transverse Fiber Conduction in Human Pulmonary Veins

Evidence for Longitudinal and Transverse Fiber Conduction in Human Pulmonary Veins Evidence for Longitudinal and Transverse Fiber Conduction in Human Pulmonary Veins Relevance for Catheter Ablation Javier E. Sanchez, MD; Vance J. Plumb, MD; Andrew E. Epstein, MD; G. Neal Kay, MD Background

More information

CARDIOINSIGHT TM NONINVASIVE 3D MAPPING SYSTEM CLINICAL EVIDENCE SUMMARY

CARDIOINSIGHT TM NONINVASIVE 3D MAPPING SYSTEM CLINICAL EVIDENCE SUMMARY CARDIOINSIGHT TM NONINVASIVE 3D MAPPING SYSTEM CLINICAL EVIDENCE SUMMARY April 2017 SUPPORTING EVIDENCE RHYTHM AF VT PUBLICATIONS Driver Domains in Persistent Atrial Fibrillation (Haissaiguerre, et al)

More information

Introduction. Methods

Introduction. Methods Europace (2015) 17, 801 806 doi:10.1093/europace/euu332 CLINICAL RESEARCH Cardiac electrophysiology Electrophysiological studies in patients with paroxysmal supraventricular tachycardias but no electrocardiogram

More information

This overview was prepared in October 2011, and updated in March 2012.

This overview was prepared in October 2011, and updated in March 2012. NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE INTERVENTIONAL PROCEDURES PROGRAMME Interventional procedure overview of percutaneous balloon cryoablation for pulmonary vein isolation in atrial fibrillation

More information

The impact of hypertension on the electromechanical properties and outcome of catheter ablation in atrial fibrillation patients

The impact of hypertension on the electromechanical properties and outcome of catheter ablation in atrial fibrillation patients Original Article The impact of hypertension on the electromechanical properties and outcome of catheter ablation in atrial fibrillation patients Tao Wang 1, Yun-Long Xia 1, Shu-Long Zhang 1, Lian-Jun Gao

More information

Ablation of persistent AF Is it different than paroxysmal?

Ablation of persistent AF Is it different than paroxysmal? Ablation of persistent AF Is it different than paroxysmal? Steven J. Kalbfleisch, MD Medical Director Electrophysiology Laboratory Ohio State University Wexner Medical Center Ross Heart Hospital Columbus,

More information

Time to Cardioversion of Recurrent Atrial Arrhythmias After Catheter Ablation of Atrial Fibrillation and Long-Term Clinical Outcome

Time to Cardioversion of Recurrent Atrial Arrhythmias After Catheter Ablation of Atrial Fibrillation and Long-Term Clinical Outcome Time to Cardioversion of Recurrent Atrial Arrhythmias After Catheter Ablation of Atrial Fibrillation and Long-Term Clinical Outcome TIMIR S. BAMAN, M.D., SANJAYA K. GUPTA, M.D., SREEDHAR R. BILLAKANTY,

More information

ABLATION TECHNIQUES FOR ATRIAL FIBRILLATION

ABLATION TECHNIQUES FOR ATRIAL FIBRILLATION ABLATION TECHNIQUES FOR ATRIAL FIBRILLATION Demosthenes G. Katritsis, MD, PhD(Lon), FRCP Athens Euroclinic Ablation for AF Cox JL, et al. Surgery for atrial fibrillation. Semin Thorac Cardiovasc Surg.

More information

Atrial Fibrillation: Electrophysiological Mechanisms and the Results of Interventional Therapy

Atrial Fibrillation: Electrophysiological Mechanisms and the Results of Interventional Therapy Vol. 8, No. 3, September 2003 185 Atrial Fibrillation: Electrophysiological Mechanisms and the Results of Interventional Therapy A.SH. REVISHVILI Bakoulev Research Centre for Cardiovascular Surgery, Russian

More information

Division of Cardiology, Northwestern University, Feinberg School of Medicine.

Division of Cardiology, Northwestern University, Feinberg School of Medicine. Reconnection Rate and Long-Term Outcome with Adenosine Provocation During Cryoballoon Ablation for Pulmonary Vein Isolation Rachel M Kaplan 1, Sanjay Dandamudi 1, Martha Bohn 1, Nishant Verma 1, Todd T

More information