HEMOSTASIS Quality Time saving Economy Practicability Quality assurance Precision
|
|
- Henry Sparks
- 6 years ago
- Views:
Transcription
1 Quality Time saving Economy Practicability Quality assurance Precision exclusive distributor of for France, Netherlands, Belgium and Luxembourg List of frozen reagents
2 In 1992, Precision BioLogic began developing an integrated line of high-quality frozen controls, calibrators and reagents from the brand. Today, Cryopep and Precision Biologic continue to grow their product offering to help meet the coagulation testing needs of labs and research organizations around the globe. THE RESULT: increased productivity in your lab. EUROPEAN DISTRIBUTION CRYOPEP SPEED / EFFICIENCY OF TRANSPORT GUARANTEED QUALITY Products in compliance with the 98/79/CE standard (except RUO mention) ISO 9001:2008 Quality Management System ISO 13485:2003 Medical Devices - Quality Management System FDA standard for USA OUR CUSTOMERS : Pharmaceutical industries National and international hospitals Medical laboratories Research laboratories RELIABILITY Our products are packed in insulated boxes in dry ice, guarantying their integrity during transport. Product Packaging and Delivery All Precision BioLogic products come in compact, color-coded packaging for easy location in your freezers. To ensure product integrity during shipment, we carefully pack and monitor orders until they arrive safely at your site. Orders may be placed via phone, fax or . 83, rue Yves Montand Montpellier - France Tel. : +33(0) Fax : +33(0) contact@cryopep.com
3 2015 Controls and Specialty Plasmas Pooled Normal Plasma Normal plasma pool that can also be used as normal controls for coagulation testing. May also be used as an alternative to in-house collected normal plasma pools. Guaranteed negative for circulating anticoagulants research and for the V Leiden, it is also suitable for dilutions of patient plasma and normal plasma. CCN-10 CCN-15 CCN x 1.5 ml 81 x 4.0 ml Normal Donor Set Set of 25 individual normal plasmas from healthy donors man and woman. Research use only. CCNS-10 HEMOSTASIS Abnormal 1 Reference Control Plasma controlling the accuracy of quantitative hemostasis assays in the borderline pathological range for 23 parameters. ARP1-05 ARP1-10 Abnormal 2 Reference Control Plasma for controlling the accuracy of quantitative hemostasis assays in the pathological range around 10% for 21 parameters. ARP2-10 Lupus Positive Control Positive control for lupus anticoagulant assays. CCLP-05 CCLP-10 Normal Reference Plasma Plasma for the calibration of quantitative hemostasis assay (23 parameters). CCNRP-05 CCNRP-10 Weak Lupus Positive Control Weak positive control plasma and close to threshold values tested for use as a positive weak control for lupus anticoagulant assays. CCWLP-05 CCWLP-10 Reference Control Normal Plasma for controlling the accuracy of quantitative hemostasis assays in the normal range (23 parameters). RCN-05 RCN-10 Low Fibrinogen Control Abnormal control for use in quantitative fibrinogen assays around 0,9 g/l. CCLF-10 CCLF25-10 Legend Frozen product Liquid product Store below -70 C Store between -40 C and -80 C Store between 2 C and 8 C
4 Reagents HEMOSTASIS CorPac TM 30 distinct normal and abnormal plasmas. Research use only. CCCP x 1.5 ml Factor II Deficient Plasma Deficient substrate for clot-based factor II assays. FDP02-10 FDP02-15 Abnormal 1 Control Abnormal control for prothrombin time (PT) and activated partial thromboplastin time (APTT) assays. CCA1-10 Factor V Deficient Plasma Deficient substrate for clot-based factor V assays. FDP05-10 FDP05-15 Abnormal 2 Control Abnormal control for prothrombin time (PT) and activated partial thromboplastin time (APTT) assays. CCA2-10 Factor VII Deficient Plasma Deficient substrate for clot-based factor VII assays. FDP07-10 FDP07-15 Heparin Control Abnormal control plasma with a sodium heparin salt for activated partial thromboplastin time (APTT) or Anti Xa. CCH-10 APCR Positive Control Heterozygous controls for the validation of the assay of the resistance to clot-based activated protein C. APCR-05 Factor VIII Deficient Plasma Deficient substrate for clot-based factor VIII assays. FDP08-10 FDP08-15 Factor IX Deficient Plasma Deficient substrate for clot-based factor IX assays. FDP09-10 FDP09-15 Expires 2 years after manufacturing date Research Use Only Expires 3 years after manufacturing date Factor X Deficient Plasma Deficient substrate for clot-based factor X assays. FDP10-10 FDP10-15
5 Factor XI Deficient Plasma Deficient substrate for clot-based factor XI assays. FDP11-10 FDP11-15 Factor XII Deficient Plasma Deficient substrate for clot-based factor XII assays. FDP12-10 FDP12-15 Prekallikrein Deficient Plasma Deficient substrate for clot-based prekallikrein assay. FDPK-10 Platelet Lysate Platelet Lysate for use in the Platelet Neutralization Procedure (PNP), a confirmatory test for lupus anticoagulant (LA). PNP x 1.0 ml Diagnostic kits Clot C TM Clot-based assay for the quantitative determination of protein C activity in citrated human plasma. CCC-15 CCC-30 (PC Deficient) (PC Deficient) Clot S TM Clot-based assay for the quantitative determination of protein S activity in citrated human plasma. CCS-15 CCS-30 (PS Deficient) (PS Deficient) C & S Diluent A buffer solution intended for use as a diluent for reagents and patient samples in coagulation tests. CSD 6 x 15 ml LA Check TM Dilute Russell s Viper Venom Time (drvvt) screening reagent. CHK-10 LA Sure TM Dilute Russell s Viper Venom Time (drvvt) confirmation reagent. SUR-10
Mohammadreza Tabatabaei IBTO COAG LAB
Tests for the Evaluation of Lupus Anticoagulants t Mohammadreza Tabatabaei MSc Hematology blood bank MSc Hematology blood bank IBTO COAG LAB Lupus Anticoagulants General Background Lupus anticoagulants
More informationInternal Quality Control in the Haemostasis laboratory. Dr Steve Kitchen Sheffield Haemophilia and Thrombosis centre & UK NEQAS Blood Coagulation
Internal Quality Control in the Haemostasis laboratory Dr Steve Kitchen Sheffield Haemophilia and Thrombosis centre & UK NEQAS Blood Coagulation Why do we need Quality control? Philadelphia Enquirer Aug
More informationA Percent Correction Formula for Evaluation of Mixing Studies
Coagulation and Transfusion Medicine / A PERCENT CORRECTION FORMULA FOR EVALUATION OF MIXING STUDIES A Percent Correction Formula for Evaluation of Mixing Studies Sheng-hsiung Chang, MD, Veronica Tillema,
More informationCoagulation an Overview Dr.Abdolreza Abdolr Afrasiabi Thal assem a & Heamophili hilia G ene i tic R esearc C en er Shiraz Medical Medic University
In The Name God Coagulation an Overview Dr.Abdolreza Afrasiabi Thalassemia & Heamophilia Genetic Research hcenter Shiraz Medical University Bleeding Clotting Hemostasis Review of platelet function Platelets
More informationInstruments smart solutions & service IGZ Instruments AG Räffelstrasse 32 CH 8045 Zürich
ADP (Adenosine-5 -Diphosphate) 101312 3 x 0.5mL ADP is a lyophilized preparation of adenosine-5 -diphosphate. The working concentration of the reconstituted reagent is 2 x 10-4 M. ADP is for use in routine
More informationInsights on the Quality of Coagulation Testing
Insights on the Quality of Coagulation Testing Piet Meijer ECAT Foundation The Netherlands No conflicts of interest HAEMOSTATIC BALANCE BLEEDING HAEMOSTATIC BALANCE THROMBOSIS HAEMOSTATIC BALANCE Thrombosis
More informationThe study has been approved by Ethics Commission. Informed consent has been given by all participants.
Evaluation of new 9NC Coagulation Tubes Background: Venous blood with sodium citrate is the most commonly obtained examination sample for coagulation determinations. The additive functions as an anticoagulant
More informationIntroduction to coagulation and laboratory tests
Introduction to coagulation and laboratory tests Marc Jacquemin Special Haemostasis Laboratory Center for Molecular and Vascular Biology University of Leuven Coagulation in a blood vessel: fibrin stabilises
More informationOptimal Utilization of Thrombophilia Testing
Optimal Utilization of Thrombophilia Testing Rajiv K. Pruthi, MBBS Special Coagulation Laboratory & Comprehensive Hemophilia Center Division of Hematology/Internal Medicine Dept of Laboratory Medicine
More informationThe LaboratoryMatters
Laboratory Medicine Newsletter for clinicians, pathologists & clinical laboratory technologists. A Initiative. HEMOSTASIS AND THE LABORATORY This issue highlights: Primary Hemostasis Screening Tests Case
More informationComparison of Samples Obtained From 3.2% Sodium Citrate Glass and Two 3.2% Sodium Citrate Plastic Blood Collection Tubes Used in Coagulation Testing
Coagulation and Transfusion Medicine / GLASS VS PLASTIC IN HEMOSTASIS TESTING Comparison of Samples Obtained From 3.2% Sodium Citrate Glass and Two 3.2% Sodium Citrate Plastic Blood Collection Tubes Used
More informationDetermination of APTT factor sensitivity the misguiding guideline
International Journal of Laboratory Hematology ORIGINAL ARTICLE The Official journal of the International Society for Laboratory Hematology INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY Determination
More informationPrimary Exam Physiology lecture 5. Haemostasis
Primary Exam Physiology lecture 5 Haemostasis Haemostasis Body s response for the prevention and cessation of bleeding. Broadly consists of: Primary Haemostasis - vascular spasm and platlet plug formation
More informationCoagulation, Haemostasis and interpretation of Coagulation tests
Coagulation, Haemostasis and interpretation of Coagulation tests Learning Outcomes Indicate the normal ranges for routine clotting screen and explain what each measurement means Recognise how to detect
More informationACTICLOT dpt REF 824. IVD C i 2 l. Dilute Prothrombin Time Test for the Determination of Lupus Anticoagulants (LA) (CPT Code No.
Sekisui Diagnostics, LLC 500 West Avenue, Stamford, CT 06902 M Tel. (203) 602-7777 Fax (203) 602-2221 INTENDED USE The ACTICLOT dpt is intended for the qualitative determination of Lupus Anticoagulants
More informationReferrals for abnormal coagulation profiles are common
A Practical Approach to Pediatric Patients Referred With an Abnormal Coagulation Profile Monica Acosta, MD; Rachel Edwards, BS; E. Ian Jaffe, MD; Donald L. Yee, MD; Donald H. Mahoney, MD; Jun Teruya, MD,
More informationPICT ANTICOAGULANT MONITORING 1. PEFAKIT PICT. Clotting Assay. PEFAKIT PiCT. PEFAKIT PICT Calibrators UFH. PEFAKIT PICT Controls UFH
1 2 3 4 PEFAKIT PiCT PEFAKIT PICT Calibrators UFH PEFAKIT PICT Controls UFH PEFAKIT PICT Calibrators LMWH Clotting Assay PICT 1. PEFAKIT PICT Package size 8-505-01 kit 80 3 vials of PiCT Activator (2mL)
More informationL iter diagnostico di laboratorio nelle coagulopatie congenite emorragiche
L iter diagnostico di laboratorio nelle coagulopatie congenite emorragiche Armando Tripodi Angelo Bianchi Bonomi Hemophilia and Thrombosis Center Dept. of Clinical Sciences and Community Health University
More informationFactor VIII Inhibitor Testing: Nijmegen Modifications, Experience and Recommendations
Factor VIII Inhibitor Testing: Nijmegen Modifications, Experience and Recommendations Bert Verbruggen Radboud University Nijmegen Medical Centre The Netherlands 2-12-2008 DISCLOSURE None 2-12-2008 2 ECAT
More informationConsultative Coagulation How to Effectively Answer Common Questions About Hemostasis Testing Session #5000
Consultative Coagulation How to Effectively Answer Common Questions About Hemostasis Testing Session #5000 Dorothy M. (Adcock) Funk, M.D. Karen A. Moser, M.D. Esoterix Coagulation September 20, 2013 Disclosures
More informationEvaluation Report. Eurolyser PT (INR) test kit (ST0180) on CUBE and smart analysers
Evaluation Report Eurolyser PT test kit (ST0180) on CUBE and smart analysers Locations Location 1: Eurolyser Diagnostica GmbH Operator: Simone Wieser Date: 30.06.2015 Specimens The specimens used for analysis
More informationBehzad Poopak, DCLS PhD
Behzad Poopak, DCLS PhD Test Report Name Age Critical Low HEMATOLOGY Activated Partial Thromboplastin Time, Plasma Critical High - 150 sec Units Fibrinogen 60 - mg/dl INR (International Normalizing
More informationEARLY ONLINE RELEASE
EARLY ONLINE RELEASE Note: This article was posted on the Archives Web site as an Early Online Release. Early Online Release articles have been peer reviewed, copyedited, and reviewed by the authors. Additional
More informationTECHNICAL SERIES. Lupus Anticoagulants: Basic Concepts and Laboratory Diagnosiss. ...Setting trends TULIP DIAGNOSTICS (P) LTD.
For the use of Registered Medical Practioners and Laboratories only TECHNICAL SERIES Lupus Anticoagulants: Basic Concepts and Laboratory Diagnosiss TULIP DIAGNOSTICS (P) LTD. Gitanjali, Tulip Block, Dr.
More informationLupus Anticoagulants (LA), Antiphospholipid (APL) Antibodies & APL Syndrome: Review & Update. Antiphospholipid. Antiphospholipid
, Antiphospholipid (APL) Antibodies & APL Syndrome: Review & Update William L. Nichols, MD Mayo Clinic College of Medicine Rochester, Minnesota USA Disclosures & Objectives (Nichols) Disclosures Relevant
More informationPlease note that the uses described in the following page(s) have not been approved or cleared by FDA, with respect to the described assay or test.
Please note that the uses described in the following page(s) have not been approved or cleared by FDA, with respect to the described assay or test. In the US, the product is intended For Research Use Only.
More informationElectrical Markets. 3M TM Heat Shrink Tubing Promotion for Construction & Industrial. Heat Shrink Tubing USA. Made in the
Electrical Markets 3M TM Heat Shrink Tubing Promotion for Construction & Industrial Heat Shrink Tubing USA Made in the With convenient, clearly-marked Made in USA packaging, 3M Heat Shrink Tubing will
More informationADMINISTRATIVE CLINICAL Page 1 of 6
ADMINISTRATIVE CLINICAL Page 1 of 6 Anticoagulant Guidelines #2: REVERSAL OF OR MANAGEMENT OF BLEEDING WITH ANTICOAGULANTS Origination Date: Revision Date: Reviewed Date: 09/12 09/12, 01/13, 11/13, 11/15
More informationMouse C-Peptide ELISA Kit
Mouse C-Peptide ELISA Kit Cat.No: DEIA4507 Lot. No. (See product label) Size 96T Intended Use The Mouse C-Peptide ELISA kit is for the quantitative determination of c-peptide in mouse serum, plasma, and
More informationDiagnosis of hypercoagulability is by. Molecular markers
Agenda limitations of clinical laboratories to evaluate hypercoagulability and the underlying cause for thrombosis what is the INR the lupus anticoagulant and the antiphospholipid antibody syndrome hassouna
More informationOral Factor Xa Inhibitors and Clinical Laboratory Monitoring
Oral Factor Xa Inhibitors and Clinical Laboratory Monitoring MELISSA L. WHITE ABSTRACT Oral anticoagulation therapy is currently undergoing great changes with the development and use of several new medications.
More informationHEMOCHRON. Whole Blood Coagulation Systems
HEMOCHRON Whole Blood Coagulation Systems Citrated Activated Partial Thromboplastin Time (APTT) Cuvette Correlation Protocol for HEMOCHRON Microcoagulation Instruments MSIG:131 10/06 Dear Medical Professional:
More informationTesting strategies for diagnosing lupus anticoagulant: decision analysis Segal J B, Lehmann H P, Petri M, Mueller L, Kickler T S
Testing strategies for diagnosing lupus anticoagulant: decision analysis Segal J B, Lehmann H P, Petri M, Mueller L, Kickler T S Record Status This is a critical abstract of an economic evaluation that
More informationLaboratory monitoring of oral anticoagulants. A/Prof. Lee Lai Heng Haematology Singapore General Hospital
Laboratory monitoring of oral anticoagulants A/Prof. Lee Lai Heng Haematology Singapore General Hospital Relevant Disclosures Educational and Travel Grants Bayer, Leo, Bristol Meyer Squib Advisory Boards
More informationHematology & Coagulation Practicum Objectives CLS - 647
Hematology & Coagulation Practicum Objectives CLS - 647 The following objectives are to be completed by the student for successful completion of this clinical rotation. The objectives within the psychomotor
More informationACQUIRED COAGULATION ABNORMALITIES
ACQUIRED COAGULATION ABNORMALITIES ACQUIRED COAGULATION ABNORMALITIES - causes 1. Liver disease 2. Vitamin K deficiency 3. Increased consumption of the clotting factors (disseminated intravascular coagulation
More informationStability of prothrombin time and activated partial thromboplastin time tests under different storage conditions
Clinica Chimica Acta 300 (2000) 13 21 www.elsevier.com/ locate/ clinchim Stability of prothrombin time and activated partial thromboplastin time tests under different storage conditions L.V. Rao *, A.O.
More informationCollection of Blood Specimens by Venipuncture for Plasma-Based Coagulation Assays Necessity of a Discard Tube
Coagulation and Transfusion Medicine / Discard Tube Unnecessary for Coagulation Assays Collection of Blood Specimens by Venipuncture for Plasma-Based Coagulation Assays Necessity of a Discard Tube Maarten
More informationBLEEDING DISORDERS Simple complement:
BLEEDING DISORDERS Simple complement: 1. Select the statement that describe the thrombocytopenia definition: A. Marked decrease of the Von Willebrandt factor B. Absence of antihemophilic factor A C. Disorder
More informationQuickVet Diagnostic System
QuickVet Diagnostic System Package insert for QuickVet PT/aPTT Coag Combo Test Version: January 4, 2017 Introduction The QuickVet PT/aPTT Coag Combo test cartridge is a quantitative coagulation test intended
More informationCYTOMEGALOVIRUS (CMV) IgM ELISA Kit Protocol
CYTOMEGALOVIRUS (CMV) IgM ELISA Kit Protocol (Cat. No.:EK-310-91) 330 Beach Road, Burlingame CA Tel: 650-558-8898 Fax: 650-558-1686 E-Mail: info@phoenixpeptide.com www.phoenixpeptide.com INTENDED USE The
More informationUse Tomorrow s Technology Today
Use Tomorrow s Technology Today Company Profile (MES) is a leading edge company specializing in rapid, automated semen analysis for both the human and the veterinary markets. The Company s comprehensive
More informationlaboratory monitoring of Direct Oral Anticoagulant: who, when and how Dr. Malake Naboulsi Hôpital Albert Haykel Laboratoire d hématologie.
laboratory monitoring of Direct Oral Anticoagulant: who, when and how Dr. Malake Naboulsi Hôpital Albert Haykel Laboratoire d hématologie. Disclosures Malake Naboulsi declare to meeting attendees that
More informationPart IV Antithrombotics, Anticoagulants and Fibrinolytics
Part IV Antithrombotics, Anticoagulants and Fibrinolytics "The meaning of good and bad, of better and worse, is simply helping or hurting" Emerson Chapter 16: Blood Coagulation and Fibrinolytic System
More informationIgG Antibodies To Toxoplasma Gondii ELISA Kit Protocol
IgG Antibodies To Toxoplasma Gondii ELISA Kit Protocol (Cat. No.:EK-310-85) 330 Beach Road, Burlingame CA Tel: 650-558-8898 Fax: 650-558-1686 E-Mail: info@phoenixpeptide.com www.phoenixpeptide.com INTENDED
More informationNew Age Anticoagulants: Bleeding Considerations
Ontario Regional Blood Coordinating Network March 23, 2012 New Age Anticoagulants: Bleeding Considerations Bill Geerts, MD, FRCPC Thromboembolism Specialist, Sunnybrook HSC Professor of Medicine, University
More informationRat Hemoglobin A1c (HbA1c) Kit Instructions
V.3 Crystal Chem Rat Hemoglobin A1c (HbA1c) Kit Instructions For the quantitative determination of hemoglobin A1c (HbA1c) in rat whole blood Catalog #80300 96 Assays For research use only. Not for use
More informationHEMATOLOGY AND COAGULATION ANALYTIC PROTOCOLS
1 of 6 Policy #: 800 (PLH-800-13) Initiated Date: 12/4/2002 Reviewed Date: 8/1/2016 Subject: HEMATOLOGY AND COAGULATION ANALYTIC PROTOCOLS Approved by: Laboratory Director, Jerry Barker (electronic signature)
More informationMouse Leptin ELISA Kit Instructions
V.6/Mar/2008 CRYSTAL CHEM INC. Mouse Leptin ELISA Kit Instructions For the quantitative determination of leptin in mouse serum or plasma and fluid Catalog #: 90030 96 Assays For Research Use Only. Not
More informationProthrombin Complex Concentrate- Octaplex. Octaplex
Prothrombin Complex Concentrate- Concentrated Factors Prothrombin Complex Concentrate (PCC) 3- factor (factor II, IX, X) 4-factor (factors II, VII, IX, X) Activated 4-factor (factors II, VIIa, IX, X) Coagulation
More informationHEMOCLOT THROMBIN INHIBITORS # CK002K Clotting assay for the quantitative measurement of hirudin and other direct thrombin inhibitors in plasma
HEMOCLOT THROMBIN INHIBITORS # CK002K Clotting assay for the quantitative measurement of hirudin and other direct thrombin inhibitors in plasma For in vitro use only For research use only Last revision
More informationTUD Sdn Bhd ( V)
Instruction for Use of TUD Evacuated Blood Collection Tubes Direction for Use of TUD Evacuated Blood Collection Tube Product name: TUD Evacuated blood collection tube I. Application: It is used for collection,
More informationSolutions for Calibration and Maintenance
SOLUTIONS Solutions for Calibration and Maintenance New Series of Solutions To meet the requirements of various applications, new categories of solutions have been created: HI 50xx series, technical solutions:
More informationIl laboratorio: verso una migliore definizione dei test
Il laboratorio: verso una migliore definizione dei test Armando Tripodi Angelo Bianchi Bonomi Hemophilia and Thrombosis Center Dept. of Clinical Sciences and Community Health University of Milano Laboratory
More informationComparison of Three Methods for Measuring Factor VIII Levels in Plasma
Coagulation and Transfusion Medicine / THREE FACTOR VIII ASSAYS Comparison of Three Methods for Measuring Factor VIII Levels in Plasma Wayne L. Chandler, MD, Chris Ferrell, MT(ASCP), Joo Lee, MT(ASCP),
More informationPa. Immunization Education Program
Pa. Immunization Education Program 2016 Maintaining the Cold Chain The cold chain is a temperature-controlled environment used to maintain and distribute vaccine in optimal condition. Provider responsibility
More informationAppendix 3 PCC Warfarin Reversal
Appendix 3 PCC Warfarin Reversal Reversal of Warfarin and Analogues 1. Principle of Procedure Guidelines for the Reversal of Oral-anticoagulation in the Event of Life Threatening Haemorrhage Prothrombin
More informationHerpes Simplex Virus 2 IgG HSV 2 IgG
DIAGNOSTIC AUTOMATION, INC. 21250 Califa Street, Suite 102 and 116, Woodland Hills, CA 91367 Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com
More informationM B Garvey. University of Toronto
Do I really need that test??? M B Garvey Professor Emeritus University of Toronto St Michael s Hospital No relevant conflicts of interest 1 HEMOSTASIS IS LIKE LOVE Everybody talks about it, nobody understands
More informationThe effect of the direct oral anticoagulants (DOACs) on haemostasis tests.
The effect of the direct oral anticoagulants (DOACs) on haemostasis tests. Emmanuel J Favaloro, Haematology, ICPMR, Pathology West, Sydney Centres for Thrombosis and Haemostasis, Westmead Hospital (with
More informationTissue type Plasminogen Activator Human Chromogenic Activity Assay Kit
ab108905 Tissue type Plasminogen Activator Human Chromogenic Activity Assay Kit Instructions for Use For the quantitative measurement of Human Tissue type Plasminogen Activator activity in cell culture
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK University Hospitals NHS Foundation Trust Haematology and Transfusion Department Mindelsohn Way Edgbaston Contact: Tel: +44 (0) 121 371 5963
More informationGeneral approach to the investigation of haemostasis. Jan Gert Nel Dept. of Haematology University of Pretoria 2013
General approach to the investigation of haemostasis Jan Gert Nel Dept. of Haematology University of Pretoria 2013 Clinical reasons to investigate haemostasis Investigating a clinically suspected bleeding
More informationProthrombin (Human) ELISA Kit
Prothrombin (Human) ELISA Kit Catalog Number KA0496 96 assays Version: 04 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Background... 3 Principle of the Assay... 3 General
More informationHemostasis Test Validation, Performance and Reference Intervals
Hemostasis Test Validation, Performance and Reference Intervals Richard A. Marlar, Ph.D. Pathology and Laboratory Medicine Oklahoma City VA Medical Center University of Oklahoma Health Sciences Center
More informationMorinaga Mouse C-peptide ELISA Kit
Morinaga Mouse C-peptide ELISA Kit For the quantitative determination of C-peptide in mouse serum, plasma, and fluid 96wells For Laboratory Use Only, not for use in diagnostic procedure Please read full
More informationWHITE PAPERS PRESENTATION VIDEO DOCUMENTATION EXPERIMENT WO NDCLOT. The WoundClot Principals for Effective Bleeding Control PRESENTATION
WHITE PAPERS PRESENTATION VIDEO DOCUMENTATION EXPERIMENT ARTICLES OUR STUDY BLEEDING CONTROL 5 POINT MODEL WO NDCLOT The WoundClot Principals for Effective Bleeding Control PRESENTATION Harnessing SCIENCE
More informationLOGO. Department of Clinical Pathology, Faculty of Medicine Siriraj Hospital, Mahidol University & Thai Society of Clinical Pathology
LOGO Improvement of Coagulation Lab Practice in Thailand via Thailand NEQAS for Blood Coagulation : 4-year Experience Nisarat Opartkiattikul MD,PhD Panutsaya Tientadakul, MD. Department of Clinical Pathology,
More informationINTACT HUMAN PROINSULIN ELISA KIT 96-Well Plate (Cat. # EZHIPI-17K )
INTACT HUMAN PROINSULIN ELISA KIT 96-Well Plate (Cat. # EZHIPI-17K ) I. Intended Use 2 II. Principles Of Procedure 2 III. Reagents Supplied 2 IV. Storage and Stability 4 V. Reagent Precautions 4 VI. Materials
More informationAac Reagent Set ELISA for the detection of Acidovorax avenae subsp. citrulli Catalog number: SRA 14800
List of contents Lot number Aac Reagent Set Item 96 wells 500 wells 1000 wells 5000 wells Capture antibody 0.150 ml 0.275 ml 0.525 ml 2.525 ml Alkaline phosphatase enzyme conjugate 0.150 ml 0.275 ml 0.525
More information4/23/2009. September 15, 2008
The Current Treatment of Deep Venous Thrombosis: Are We Doing Enough? George H. Meier, MD Professor and Chief Division of Vascular Surgery University of Cincinnati College of Medicine Cincinnati, Ohio
More informationLupus Anticoagulant Testing Performance and Practices by North American Clinical Laboratories
Coagulation and Transfusion Medicine / Lupus Anticoagulant Testing Lupus Anticoagulant Testing Performance and Practices by North American Clinical Laboratories Francine R. Dembitzer, MD, 1 Marlies R.
More informationRayBio Human Phospho-DDR1 (Tyr792) ELISA Kit
RayBio Human Phospho-DDR1 (Tyr792) ELISA Kit Catalog #: PEL-DDR1-Y792 User Manual Last revised March 22, 2018 Caution: Extraordinarily useful information enclosed ISO 13485 Certified 3607 Parkway Lane,
More informationMonitoring the Health of Transplanted Organs DONOR GENOTYPING MANUAL
Monitoring the Health of Transplanted Organs DONOR GENOTYPING MANUAL 10101 Innovation Drive. Suite 600. Wauwatosa, WI 53226 1-888-214-3151 MKT-008 v3.0 MKT-008 v3.0 TABLE OF CONTENTS I Intended Use...
More informationRayBio Human Phospho-DDR1 (Tyr792) and Total DDR1 ELISA Kit
RayBio Human Phospho-DDR1 (Tyr792) and Total DDR1 ELISA Kit Catalog #: PEL-DDR1-Y792-T User Manual Last revised March 22, 2018 Caution: Extraordinarily useful information enclosed ISO 13485 Certified 3607
More informationActivation of Factor IX by the reaction product of tissue factor and
Proc. Natl. Acad. Sci. USA Vol. 74, No. 12, pp. 5260-5264, December 1977 Biochemistry Activation of Factor IX by the reaction product of tissue factor and Factor VII: Additional pathway for initiating
More informationThe Taipan snake venom time: a new test for lupus anticoagulant
J Clin Pathol 1994;47:497-51 The Taipan snake venom time: a new test for lupus anticoagulant 497 Department of Haematology, University College London Medical School, London WClE 6HX M Rooney T McNally
More informationCover Page. The handle holds various files of this Leiden University dissertation
Cover Page The handle http://hdl.handle.net/1887/37409 holds various files of this Leiden University dissertation Author: Engbers, Marissa Title: Conventional and age-specific risk factors for venous thrombosis
More informationHow Good is your INR? The Use of Certified Plasmas in PT/INR Testing. INR System. How Good is your INR? Outline
How Good is your INR? The Use of Certified Plasmas in PT/INR Testing Dot Adcock, MD Esoterix Coagulation Mayo/NASCOLA Coagulation Testing Quality Conference April 25, 2007 How Good is your INR? The Use
More informationBlood coagulation and fibrinolysis. Blood clotting (HAP unit 5 th )
Blood coagulation and fibrinolysis Blood clotting (HAP unit 5 th ) Vessel injury Antithrombogenic (Favors fluid blood) Thrombogenic (Favors clotting) 3 Major systems involved Vessel wall Endothelium ECM
More informationSee external label 96 tests HSV 2 IgA. Cat #
DIAGNOSTIC AUTOMATION, INC. 23961 Craftsman Road, Suite D/E/F, Calabasas, CA 91302 Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com See external
More informationJohn Davidson Consultant in Intensive Care Medicine Freeman Hospital, Newcastle upon Tyne
John Davidson Consultant in Intensive Care Medicine Freeman Hospital, Newcastle upon Tyne Overview of coagulation Testing coagulation Coagulopathy in ICU Incidence Causes Evaluation Management Coagulation
More informationRayBio Human Phospho-DDR2 (Tyr740) and Total DDR2 ELISA Kit
RayBio Human Phospho-DDR2 (Tyr740) and Total DDR2 ELISA Kit Catalog #: PEL-DDR2-Y740-T User Manual Last revised March 22, 2018 Caution: Extraordinarily useful information enclosed ISO 13485 Certified 3607
More informationRayBio Human Phosphotyrosine BTK ELISA Kit
RayBio Human Phosphotyrosine BTK ELISA Kit Catalog #: PEL-BTK-Y User Manual Last revised August 10, 2016 Caution: Extraordinarily useful information enclosed ISO 13485 Certified 3607 Parkway Lane, Suite
More informationToxoplasma gondii IgM ELISA Kit
Toxoplasma gondii IgM ELISA Kit Catalog Number KA0226 96 assays Version: 02 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Intended Use... 3 Background... 3 Principle
More informationFIGURE 1. Coagulation cascade. a = activated factor; Ca = calcium; PL = phospholipid. Adapted from Biochemistry, 2 with permission from American Chemi
CONCISE REVIEW FOR CLINICIANS PROLONGED PT AND APTT How to Interpret and Pursue an Abnormal Prothrombin Time, Activated Partial Thromboplastin Time, and Bleeding Time in Adults ARIF H. KAMAL, MD; AYALEW
More informationMASSIVE TRANSFUSION DR.K.HITESH KUMAR FINAL YEAR PG DEPT. OF TRANSFUSION MEDICINE
MASSIVE TRANSFUSION DR.K.HITESH KUMAR FINAL YEAR PG DEPT. OF TRANSFUSION MEDICINE CONTENTS Definition Indications Transfusion trigger Massive transfusion protocol Complications DEFINITION Massive transfusion:
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
Laboratory locations: 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Blood Sciences Pathology Building Hull Royal Infirmary Anlaby Road Hull HU3 2JZ Contact: Dr Andrew Botham Tel: +44 (0)1482
More informationTRANSFUSION GUIDELINES FOR CARDIOTHORACIC UNIT 2006
TRANSFUSION GUIDELINES FOR CARDIOTHORACIC UNIT 2006 CTU blood product transfusion guidelines 2006 1 Summary of guidelines RED CELLS (10-15ml/kg) This applies to ward patients / icu patients who are stable.
More informationH.Pylori IgG
DIAGNOSTIC AUTOMATION, INC. 21250 Califa Street, Suite 102 and116, Woodland Hills, CA 91367 Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com
More information27027 Tourney Road Valencia, CA 91355 800 421 7110 www.specialtylabs.com Test Updates September 25, 2009 Dear Colleague: Specialty Laboratories is pleased to announce a new assay, PT and PTT-LA Mixing
More informationH.Pylori IgG Cat # 1503Z
DIAGNOSTIC AUTOMATION, INC. 23961 Craftsman Road, Suite D/E/F, Calabasas, CA 91302 Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com See external
More informationEvaluation of the Precision and Accuracy of the INRatio 2 Prothrombin Time (PT) Monitoring System
Evaluation of the Precision and Accuracy of the INRatio 2 Prothrombin Time (PT) Monitoring System Grace DeSantis, PhD Lisa Croner, PhD Michealle Havenhill, BA Shari Kipp, BSc (Honours) MBA Inverness Medical,
More informationExendin-4 (Exenatide) ELISA Kit
Exendin-4 (Exenatide) ELISA Kit Catalog: DEIABL227 For the quantitative determination of Exendin-4 in serum or plasma using competitive ELISA method For Research Use Only. Protocol Provided for Informational
More informationA Patient with a Prolonged Activated Partial Thromboplastin Time and a Deep Intracerebral Haemorrhage
This is an Open Access article licensed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 3.0 License (www.karger.com/oa-license), applicable to the online version of the article
More informationSAMPLE PROCEDURE , 07/11
SAMPLE PROCEDURE This Sample Procedure is not intended as a substitute for your facility s Procedure Manual or reagent labeling, but rather as a model for your use in customizing for your laboratory s
More informationRayBio Human, Mouse and Rat Phospho-NF-kB P65 (Ser536) and Total NF-kB P65 ELISA Kit
RayBio Human, Mouse and Rat Phospho-NF-kB P65 (Ser536) and Total NF-kB P65 ELISA Kit Catalog #: PEL-NFKBP65-S536-T User Manual Last revised October 10, 2017 Caution: Extraordinarily useful information
More informationph Technical Calibration Solutions solutions Technical Solutions (±0.01 ph) for Each Point of the ph Scale Easy to Use Single Dose Sachets
HI5000 Series Technical Calibration Technical (±0.01 ) for Each Point of the Scale To obtain precise and valid measurements, the meter and electrode must be calibrated at a minimum of two different points,
More informationNew Anticoagulants: Laboratory Monitoring?? Dr Steve Kitchen Sheffield Haemostasis and Thrombosis centre UK
New Anticoagulants: Laboratory Monitoring?? Dr Steve Kitchen Sheffield Haemostasis and Thrombosis centre UK Ideal Anticoagulant (Hirsh et al 2004) High efficacy to safety ratio Predictable dose response
More information