Implants for primary surgery
|
|
- Louisa Campbell
- 6 years ago
- Views:
Transcription
1 Implants for primary surgery Catalogue - primary implants THOPSTY
2 Hip Knee Shoulder Finger ist of materials MTEI ISO ČSN DIN STM Stainless steel Wrought high nitrogen stainless steel Unalloyed titanium W.Nr. 1.1 F 1 Grade 17 0 W.Nr..70 F 67 Grade 1 Wrought titanium Ti6l alloy W.Nr..716 F 16 TI-6I- E.-I. Co-Cr-Mo casting alloy - F 7 Wrought Co-Cr-Mo alloy - Ultra-high molecular weight polyethylene - F 6 Crosslinked ultra-high molecular weight polyethylene - F 6 Polymethylmethacrylate (PMM) Ceramic BIOOX delta 67
3 Contens HIP ist of implants... - Femoral components Plugs and collar washers...17 cetabular components Heads... - KNEE ist of implants Femoral components... 7 Tibial components Inserts Patellar components... SHOUDE... - DI HED FINGE
4 Hip Knee Shoulder Finger Hemiarthroplasty type PODI (see page 6) type CSB one - piece (see page 7) type CSB modular (see page ) Cemented femoral stems type CSC (see page 9) type PODI (see page ) type BEZNOSK TIO cemented (see page 11) Cementless femoral stems type BEZNOSK TIO cementless (see page ) type BEZNOSK TIO cementless H (see page 1) type BEZNOSK TIO modular (see page 1) typ BEZNOSK TIO modular H (see page ) type SF (see page 16)
5 Cemented cups type 0 (see page 1) type PODI (see page 19) Cementless shells type SF (see pages 0-) Hip joint head replacements Metal (see page ) Cobalt (see page ) Ceramic (see page ) Hemiarthroplasty (see page ) Biarticular (see page )
6 11 Hip Knee Shoulder Finger Cemented hip hemiarthroplasty - type Poldi Material: Stainless steel (ISO -1) Diameter D Note: CCD angle
7 Cemented hip hemiarthroplasty - type CSB Material: Stem - Stainless steel (ISO -1) Centralizer - PMM 10 Diameter D * * * 9 *available as custom-made option only 9 of centralizer 170 Note: CCD angle - 1 7
8 Hip Knee Shoulder Finger Cemented stem - type CSB Material: Stem - Wrought high nitrogen stainless steel (ISO -9) Centralizer - PMM / of centralizer 170 Note: CCD angle - 1
9 Cemented stem - type CSC Material: Stem - Wrought high nitrogen stainless steel (ISO -9) Centralizer - PMM /1 0 7, of centralizer of stem B B 1 0/ Note: CCD angle - 1 9
10 Hip Knee Shoulder Finger Cemented stem - type Poldi Material: Wrought high nitrogen stainless steel (ISO -9) /1 C C 1-N 9, 9 1-S 11 -N 9, -S B, -N 11 -S 1, -B Note: CCD angle - 10
11 Cemented stem - type BEZNOSK TIO Material: Stem - Wrought high nitrogen stainless steel (ISO -9) Centralizer - PMM /1 Cemented stem , , , , 00 11, ,0 00 1, , , , 00 Centralizer PMM Note: CCD angle
12 Hip Knee Shoulder Finger Cementless stem - type BEZNOSK TIO Material: Wrought titanium Ti6l alloy (ISO -) /1 01 1,0 0 1, 1 1 1,0 0 1, 1, , 1,0 6 10, ,0 0 16, Note: CCD angle - 1
13 Cementless stem type BEZNOSK TIO H Material: Wrought titanium Ti6l alloy (ISO -) /1 01 1,0 0 1, 1 1 1,0 0 1, , , 1,0 6 10, ,0 0 16, Note: CCD angle - 1 1
14 Hip Knee Shoulder Finger Cementless modular stem - type BEZNOSK TIO Material: Stem - Wrought titanium Ti6l alloy (ISO -) Neck - Wrought titanium Ti6l alloy (ISO -) 01 1, , , , 06 1, , 0 1, , , , 0 varus/retro valgus/ante varus/ante valgus/retro 1 standard ante/retro varus/valgus varus/ante valgus/retro varus/retro valgus/ante Neck type 1 Neck description Implant reference STNDD 1 / 0 T 1991 NTE/ETO 1 / 199 US/GUS / 0 T 1 / 0 T 199 US/ETO GUS/NTE US/NTE GUS/ETO / () () 1 / () () 199 US/NTE GUS/ETO US/ETO GUS/NTE / () () 1 / () () 199 1
15 Cementless Modular Stem Type Beznoska TIO H Material: Stem - Wrought titanium Ti6l alloy (ISO -) Krček - Kobalt-chrom-molybdenová slitina (ISO -) 01 1, , , , 196 1, , 19 1, , , , 19 varus/retro valgus/ante varus/ante valgus/retro 1 standard ante/retro varus/valgus varus/ante valgus/retro varus/retro valgus/ante Neck type Neck description Implant reference 1 STNDD 1 / 0 T 191 NTE/ETO 1 / 19 US/GUS / 0 T 1 / 0 T 19 US/ETO GUS/NTE US/NTE GUS/ETO / () () 1 / () () 19 US/NTE GUS/ETO US/ETO GUS/NTE / () () 1 / () () 19
16 Hip Knee Shoulder Finger Cementless stem - type SF Material: Wrought titanium Ti6l alloy (ISO -) /1 S standard M S / 1 /S, / 11/S 11, / 11 0 /S, / 0 1/S 1, / 1 0 1/S 1, / 1 0 /S, / 60 16/S 16, / /S 17, / /S 1, / Ø D Ø D 1 M tapered mediolaterally / 1 /M, / 11/M 11, / 11 /M, / 1/M 1, / 1 1/M 1, / 1 /M, / 16/M 16, / 16 17/M 17, / 17 1/M 1, / Note: CCD angle
17 Plug under cemented femoral stem Material: UHMWPE (ISO -) Femoral stem collar washer Material: UHMWPE (ISO -) B S S 6 B 11, 1 1, 11, 1 1, 11, 1 1, 11, 1 1,
18 Hip Knee Shoulder Finger Cemented cup - type 0 Material: Cup - Crosslinked UHMWPE (ISO -) Centralizers - PMM Standard (N) Ø = mm Ø = mm Ø=6 mm Ø Offset () Ø Ø = mm Ø = mm Ø=6 mm ntiluxation () Ø Ø = mm Ø = mm Ø=6 mm
19 Material: UHMWPE (ISO -) Ø M S M 9 9 9,, 7, 9,, Standard Ø Ø M S M ,, 7, 9,, With rim Ø Ø Ø M S M 9 9 Flat Ø Ø M S M 9 9 9,, 7, 9, ntiluxation 9700, Ø 0 00 Ø M 9 6 9,, ntiluxation with rim Ø S M 9 Flat with rim Ø 19 Cemented cup - type Poldi
20 Hip Knee Shoulder Finger Cementless shell - type SF Material: Unalloyed titanium (ISO -) Cementless shell - standard Cementless shell - flat ,,,, 6, 7,,
21 Cementless insert - type SF Insert - type SF - standard Shell diameter - D Ø Shell diameter - D Ø Material: Crosslinked UHMWPE (ISO -) Ø Insert - type SF with offset Shell diameter - D Ø Shell diameter - D Ø Ø Insert - type SF - flat Shell diameter - D Ø Ø
22 Hip Knee Shoulder Finger Screw - type SF Material: Wrought titanium alloy Ti6l (ISO -),, Cortical screw for cementless shell - type SF Cancellous screw for cementless shell - type SF Ø D, Ø D 6,
23 Hip joint head replacements Material: Metal head k - Wrought high nitrogen stainless steel (ISO -9) Cobalt head CoCrMo - Wrought Co-Cr-Mo alloy (ISO -) /1 6 Metal head K Neck length S 660 M 6 60 X 67 XX 6 S M X XX S M X XX /1 Cobalt head CoCrMo 6 Neck length M S 6760 M X 677 XX 67 S M X XX S M X XX
24 Hip Knee Shoulder Finger Hip joint head replacements Material: Ceramic head: BIOOX() delta Hemiarthroplasty head: Stainless steel (ISO -1) Biarticular head: Head cover - Stainless steel (ISO -1) Head inner - Wrought high nitrogen stainless steel (ISO -9) Head liner - UHMWPE (ISO -) Ceramic head /1 6 Neck length S M S M S M /1 Hemiarthroplasty head /1 Biarticular head
25 ist of implants Total knee joint replacement: - type S (with CP) - type SS (without CP) - type S/N (computer assisted) Total knee joint replacement: - type S/P (with rotary tibial plateau)
26 Hip Knee Shoulder Finger dmissible combinations of S components with other knee replacement components made by BEZNOSK td. Patellar component Femoral component type S/N Femoral component type SS PE liner type S/P PE liner type S PE liner type SS Tibial component type S/P Tibial component type S 6
27 Femoral component - type S/N Material: Co-Cr-Mo casting alloy (ISO -) eft () / right () transverse B anteroposterior B Femoral component - type SS Material: Co-Cr-Mo casting alloy (ISO -) eft () / right () transverse B anteroposterior B
28 Hip Knee Shoulder Finger Tibial component - type S Material: Wrought titanium Ti6l alloy (ISO -) B 1 eft () / right () transverse B anteroposterior Tibial component modular - type S Material: Wrought titanium Ti6l alloy (ISO -) B 1 eft () / right () transverse B anteroposterior
29 Tibial component - type S/P Material: Co-Cr-Mo casting alloy (ISO -) B transverse B anteroposterior Stem of tibial component - type S Material: Wrought titanium Ti6l alloy (ISO -) ength mm
30 Hip Knee Shoulder Finger Insert - type S Material: UHMWPE (ISO -) C B eft insert ight insert Thickness C B Thickness C B
31 1 Material: UHMWPE (ISO -) Thickness C 0 B C B Thickness C B eft insert ight insert Insert - type SS
32 B C Thickness C B Tloušťka C B eft insert ight insert / / Material: UHMWPE (ISO -) Insert - type S/P Hip Knee Shoulder Finger
33 Insert - type S/S Material: UHMWPE (ISO -) Thickness C transverse B anteroposterior C Patellar component B Material: UHMWPE (ISO -) Ø16 Note: For femoral coponents S/N, SS and S.
34 Hip Knee Shoulder Finger Cemented shoulder hemiarthroplasty Material: Stainless steel (ISO -1) B ,,, 9, xb
35 Humeral head resurfacing Material: Co-Cr-Mo casting alloy (ISO -) D H D H 1 nižší vyšší 6 1,, 00 0 nižší vyšší, 1, nižší vyšší, 16 1, 0 nižší vyšší 6, 17, 0, 1 nižší vyšší
36 Hip Knee Shoulder Finger adial head Material: Wrought high nitrogen stainless steel (ISO -9) Ø D Ø D Marking Number 9 0/S /M 0/ /S /M / /S /M / /S /M 6/
37 adial head stem Material: Wrought high nitrogen stainless steel (ISO -9) Ø D Ø D Stem ngle Marking Number 7 9 / / 7/ 7/ 9/ 9/
38 Hip Knee Shoulder Finger TMCJ - Cementless stem - type T/II (Ti + H) Material: Wrought titanium Ti6l alloy (ISO -) + H TMCJ - Cementless stem - type T Material: Wrought titanium Ti6l alloy (ISO -)
39 TMCJ - Neck - type T/II Material: Wrought Co-Cr-Mo alloy (ISO -) D D ersion D Straight alg TMCJ - Cementless shell - type T/III Material: Wrought titanium Ti6l alloy (ISO -) + H D1 D
40 Hip Knee Shoulder Finger TMCJ - Insert of cup - type T/III, for head mm Material: Crosslinked UHMWPE (ISO -) D 117 D TMCJ - Cemented cup - type T/II Material: Crosslinked UHMWPE (ISO -) D1 D1 D 10 D 0
41 TMCJ - eplacement of trapezium - type T Material: Wrought Co-Cr-Mo alloy (ISO -) /B C /B - C 1/ - 9 /16-16/ TMCJ - Insert of trapezium - type T Material: Crosslinked UHMWPE (ISO -) C D C/D D 9/ / 11/
42 Notes
43
44 Contact Export: tel.: BEZNOSK, s.r.o. Dělnická 77, 7 01 Kladno, Czech epublic export@beznoska.cz tel.: GSM: fax:
Revision systems. Catalogue - revision implants ARTHROPLASTY
evision systems Catalogue revision implants ATHOPASTY Material for implants Contens ist of materials MATEIA ISO DIN ASTM Stainless steel Wrought high nitrogen stainless steel Unalloyed titanium 321 329
More informationIndividual oncological implants
Individual oncological implants Catalogue - individual oncological implants ONCOLOGICAL Materials for implants List of materials MATERIAL ISO ČSN DIN ASTM Stainless steel 5832-1 17350 výběr 17 443 W.Nr.
More informationHip Joint Stem Type BEZNOSKA TRIO
Hip Joint Stem Type BEZNOSKA TRIO Primary Hip Joint Implants Femoral Components ARTHROPASTY Implant Description Surgical Technique Instrumentation Set Catalogue Implant Description Characteristics of implants:
More informationCementless femoral stem type SF
Cementless femoral stem type SF Cementless Femoral Hip Joint Components ARTHROPLASTY Implant Description Surgical Technique Instrumentation Set Catalogue Preface The cementless stem of a total hip joint
More informationCemented femoral stem - type CSC
Cemented femoral stem - type CSC Cemented Femoral Hip Joint Components ARTHROPLASTY Implant Description Preface The cemented femoral stem type CSC with centralizer was designed using the latest knowledge
More informationPRODUCT SCHEDULE FOR CERTIFICATE CE JRI ORTHOPAEDICS LIMITED
HIP STEM (Class III) Active Stem Active H-AC Stem / 09mm - 16mm Cemented Hemiarthroplasty (formally LOL 127) Cemented Hemiarthroplasty Stem / X-X-Small - Large Cemented Hemiarthroplasty Stem - Long / Small
More informationSurgical Procedure Trauma shoulder hemiarthroplasty
Surgical Procedure Trauma shoulder hemiarthroplasty Traumatic Arthroplasty of Shoulder ARTHRLOPLASTY Introduction Surgical Technique Content Introduction... 2 Sizes... 2 Instruments for implantation of
More informationRevision Modular Stem type RMD
Revision Modular Stem type RMD Cementless Femoral Hip Joint Components Revision Systems Implant Description Surgical Technique Instrumentation Set Catalogue Preface Revision modular stem (RMD) is a solution
More informationHOSPITAL "A" (2007) ORTHOPEDIC JOINT IMPLANT COMPONENT MATRIX
HOSPITAL "A" (2007) ORTHOPEDIC JOINT IMPLANT COMPONENT MATRIX HIP IMPLANTS TOTAL HIPS Ultra High Demand (metal on metal) Femur, ingrowth Femoral head, metal Acetabular shell, ingrowth Acetabular liner,
More informationEC Certification. FULL QUALITY ASSURANCE SYSTEM Directive 93/42/EEC for Medical Devices, Annex II excluding (4)
EC Certification FULL QUALITY ASSURANCE SYSTEM Directive 93/42/EEC for Medical Devices, Annex II excluding (4) We hereby declare that an examination of the under mentioned full quality assurance system
More informationTOTAL HIP REPLACEMENT:
THR Prosthesis Design TOTAL HIP REPLACEMENT: PROSTHESIS DESIGN FEATURES JESS JOHNSTON & MELINDA ZIETH History of Hip Prosthesis Joint Replacement Registry Implant Design Technology & Future History and
More informationDUAL MOBILITY CUP, CEMENTED OR CEMENTLESS
HIP Documentation DUAL MOBILITY CUP, CEMENTED OR CEMENTLESS >>DUAL MOBILITY ACETABULAR CUPS Dual mobility acetabular cup P r Gilles Bousquet invented the concept of dual mobility more than thirty years
More informationOPTIMAL revision/reconstruction cementless femoral stem with a modular neck
OPTIMAL revision/reconstruction cementless femoral stem with a modular neck : important components of the intra medullary part l Cementless femoral stem partial HAP l Double curve in the sagittal plane
More information*smith&nephew POLARCUP Dual Mobility System. Product Information
Product Information *smith&nephew POLARCUP Dual Mobility System Dual Mobility 30 Years of Clinical Experience Concept combining an extended ROM, a low rate of dislocation and unexpectedly limited wear.
More informationHip Implants. Hip Implants. 6 Your partner for implants and trauma products. Euromed Implants GmbH General Catalogue
6 Modular Straight Cemented Stem The modular straight cemented stem hip prosthesis is designed to be used as a primary and revision total hip. The 4 stem sizes allow accurate matching of prosthesis to
More informationANATOMIC Fixed Bearing Total Knee System Posterior Stabilised Version Cemented or Cementless Options
ANATOMIC Fixed Bearing Total Knee System Posterior Stabilised Version Cemented or Cementless Options ANATOMIC l Anatomic femoral component design based on a study of 420 knees digitised using the AMPLIVISION
More informationCement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter
Design Philosophy Cementless Stems of 12/14 Taper Stem Length Neck shaft Angle STEM-N3 STEM-N4 STEM-N5 STEM-N6 STEM-N7 STEM-N8 STEM-N9 123 mm 125 mm 130 mm 135 mm 140 mm 145 mm 150 mm 132 Cement Polished
More informationSection of Modular Hip Prostheses cemented. TMC-3 Modular Hip Prosthesis, cemented. TMC-3 Modular Hüftprothese, zementiert
Section of Modular Hip Prostheses cemented TMC-3 Modular Hip Prosthesis, cemented TMC-3 Modular Hüftprothese, zementiert Prothèse de hanche modulaire TMC-3, cimentée Indication : The TMC-3 Modular hip
More informationFurlong H-A.C. THR System
Important Information Please read prior to use in a clinical setting. The Surgeon should be familiar with the operative technique. Caution Federal (U.S.A) law restricts this device to sale by or on the
More informationMerete BioBall The Innovative Hip Endoprosthesis Head Adapter System
Merete the «BioBall Company» You are better off with BioBall Your Indispensable Assistant in Hip Arthroplasties. Merete BioBall The Innovative Hip Endoprosthesis Head Adapter System 2 BioBall System Merete
More informationAesculap Trilliance Triple Tapered Polished Hip Stem
Aesculap Trilliance Triple Tapered Polished Hip Stem Aesculap Orthopaedics Trilliance Triple Tapered Polished Hip Stem CONTENTS 2 Contents Page Trilliance Philosophy 4 Trilliance Design 6 Trilliance Implants
More informationCONSENSUS ORTHOPEDICS INC.
CONSENSUS ORTHOPEDICS INC. CONSENSUS HIP SYSTEMS Instructions for Use (IFU) IMPORTANT INFORMATION FOR SURGEON: PLEASE READ PRIOR TO IMPLANTING THIS DEVICE IN A CLINICAL SETTING. THE SURGEON SHOULD BE FAMILIAR
More informationEnhancing stability and increasing range of motion. Metasul LDH Large Diameter Head
Enhancing stability and increasing range of motion Metasul LDH Large Diameter Head The Metasul large diameter head technology is the result of in-depth research, development and clinical experience that
More informationSection of total knee replacement. Total Knee Replacement System. Knieendoprothesen System. Système de prothèse totale de genou
Section of total knee replacement Total Knee Replacement System Knieendoprothesen System Système de prothèse totale de genou Introduction: This knee system features great versality with its modular component
More informationLUMiC. Surgical Technique
LUMiC Surgical Technique LUMiC Surgical Technique LUMiC is developed in cooperation with Prof. Dr. A.H.M. Taminiau and Dr. P.D.S. Dijkstra, LUMC Leiden, The Netherlands. Table of contents Surgical Technique...5
More informationDistal Humerus 30mm surgical technique
Distal Humerus 30mm surgical technique Distal Humerus 30mm surgical technique MUTARS was developed in co-operation with Prof. Dr. W. Winkelmann (former director) and Prof. Dr. G. Gosheger (director),
More informationTrinity. Advanced Bearing Acetabular System Surgical technique
Advanced Bearing Acetabular System Surgical technique Contents Operative summary Introduction Pre-operative planning Acetabular preparation Acetabular reaming Reamer guide Acetabular shell trials Acetabular
More informationInnovation in Medical Technology. BIOTECH GroupG
Innovation in Medical Technology BIOTECH GroupG BIOTECH MULTI-NATIONAL GERMAN - BASED Developer, Manufacturer, Distributor HIP-,, KNEE-,, TRAUMA- SPINE-IMPLANTS IMPLANTS BIOTECH Factories and Offices Plants
More informationKRI M-O-M knee reconstruction implant surgical technique Femorotibial M-O-M coupling
knee reconstruction implant surgical technique Femorotibial M-O-M coupling knee reconstruction implant surgical technique Femorotibial M-O-M coupling MUTARS was developed in co-operation with Prof. Dr.
More informationThe Leader in Orthopaedic Innovation
The Leader in Orthopaedic Innovation Wright is a leading international manufacturer and distributor of superior, easy to use, and innovative orthopaedic implants and instrumentation. For over 50 years,
More informationDistal Humerus surgical technique
Distal Humerus surgical technique Distal Humerus surgical technique MUTARS was developed in co-operation with Prof. Dr. W. Winkelmann, and Prof. Dr. G. Gosheger, Clinic and Polyclinic for General Orthopedics
More informationFLH183 04/08. Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom. Tel. +44 (0) Fax: +44 (0)
FLH183 04/08 Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom Tel. +44 (0)1656 655221 Fax: +44 (0)1656 645454 Exceed ABT Operative Technique The Exceed ABT TM acetabular
More informationOptimum implant geometry
Design Rationale Optimum implant geometry Extending the proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available
More informationHip Joint Prostheses
Translated English of Chinese Standard: YY0118-2005 www.chinesestandard.net Sales@ChineseStandard.net PHARMACEUTICAL INDUSTRY STANDARD YY ICS 11.040.40 OF THE PEOPLE S REPUBLIC OF CHINA C 35 YY 0118-2005
More informationLPS SYSTEM POCKET GUIDE
LPS SYSTEM POCKET GUIDE Implants Procedural Uses Instruments & Trials L P S Limb Preservation System L P S Limb Preservation System The purpose of this document is to review the LPS (Limb Preservation
More informationMetaFix Cementless Total Hip Replacement Product overview
MetaFix Cementless Total Hip Replacement Product overview MetaFix Evolution Versatility Simplicity Founded on 20 years experience in cementless technology with a proven, world-leading stem design, MetaFix
More informationCOMMERCIAL LEAFLET. Inventor of dual mobility. in Novae. range
COMMERCIAL LEAFLET Inventor of dual mobility Novae range in 1975 Novae range Novae concept SUNFIT TH The dual mobility concept was invented in 1975 by Professor Gilles BOUSQUET and the engineer André RAMBERT,
More informationTotal Knee surgical technique
Total Knee surgical technique Total Knee surgical technique MUTARS was developed in co-operation with Prof. Dr. W. Winkelmann and Prof. Dr. G. Gosheger, Clinic and Polyclinic for General Orthopedics at
More informationAesculap Plasmafit. Cementless Acetabular Cup System. Aesculap Orthopaedics
Aesculap Plasmafit Cementless Acetabular Cup System Aesculap Orthopaedics Aesculap Plasmafit Cementless Acetabular Cup System 2 Content Plasmafit Concept 4 Plasmafit System 6 Plasmafit Surface 8 Plasmafit
More informationCC TRIO VERSAFITCUP. Surgical Technique. each to their own. Hip Knee Spine Navigation
VERSAFITCUP CC TRIO each to their own Surgical Technique Hip Knee Spine Navigation Versafitcup CC TRIO Surgical Technique Hip Knee Spine Navigation EACH TO THEIR OWN The Versafitcup CC Trio is a range
More informationoperative technique Kent Hip
operative technique Kent Hip The Kent Hip Operative Technique The Kent Hip was developed by Mr Cliff Stossel, FRCS in Maidstone, Kent, UK and first implanted in 1986. It was designed to deal with problems
More informationFeaturing. Technology. Product Rationale
Featuring Technology Product Rationale 2 Optimum implant geometry Extending proven TRI-LOCK heritage The original TRI-LOCK Stem was introduced in 1981. This implant was the first proximally coated tapered-wedge
More informationDiaphyseal implant surgical technique
Diaphyseal implant surgical technique Diaphyseal implant surgical technique MUTARS was developed in co-operation with Prof. Dr. W. Winkelmann (former director) and Prof. Dr. G. Gosheger (director), Clinic
More informationHip Product Brochure
Hip Product Brochure Dynasty Acetabular Cup System Dynasty Porous-Coated System Dynasty Biofoam System 64-68mm 8 Screw Holes Shell 46-68 in 2mm increments 46-76 in 2mm increments Head Options Metal & Ceramic
More informationOperating Instruction. Müller Hip Stem
Müller Hip Stem Ortho Select GmbH Eltastrasse 2 D 78573 Wurmlingen Germany Tel: +49-(0)7461-96632-30 Fax: +49-(0)7461-96632-35 info@ortho-select.de www.ortho-select.de 12009 Introduction and product description
More informationProximal Humerus surgical technique
Proximal Humerus surgical technique Proximal Humerus surgical technique MUTARS was developed in co-operation with Prof. Dr. W. Winkelmann, and Prof. Dr. G. Gosheger, Clinic and Polyclinic for General
More informationDistal Femur M-O-M Surgical technique with RS stem
Distal Femur M-O-M Surgical technique with RS stem Distal Femur M-O-M Surgical technique with RS stem MUTARS was developed in co-operation with Prof. Dr. W. Winkelmann (former director) and Prof. Dr.
More informationLubinus Classic Plus Hip Prosthesis System
Lubinus Classic Plus Hip Prosthesis System Presented by: Waldemar Link GmbH & Co. KG Barkhausenweg 10 22339 Hamburg, Germany P.O. Box 63 05 52 22315 Hamburg, Germany Tel.: +49 40 53995-0 Fax: +49 40 5386929
More informationBone Bangalore
Dr Suresh Annamalai MBBS, MRCS(Edn), FRCS( Tr & Orth)(Edn), FEBOT(European Board), Young Hip and Knee Fellowship(Harrogate, UK) Consultant Arthroplasty and Arthroscopic Surgeon Manipal Hospital, Whitefield,
More informationConsistency in U2 Knee System over Time
U2 TM Knee System Consistency in U2 Knee System over Time Share the same femoral profile of all types allow inter-changibility Uniform AP/ML dimensions in all tibial components enhance intraoperative flexibility
More informationBi-Polar 22.2mm & 28mm System - Operative technique
Disclaimer Biomet UK Ltd, as the manufacturer of this device, does not practice medicine and does not recommend any particular surgical technique for use on a specific patient. The surgeon who performs
More informationProduct Information. *smith&nephew POLARCUP Dual Mobility System
APPLYING SCIENCE TO MOBILITY Combined with VERILAST Technology for unmatched performance Product Information *smith&nephew POLARCUP Dual Mobility System APPLYING SCIENCE TO MOBILITY Combined with VERILAST
More informationOptimum implant geometry
Design Rationale Optimum implant geometry Extending proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available
More informationProduct Portfolio. Consensus Knee Systems. Consensus Hip Systems
1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100, 916-355-7190 info@consensusortho.com consensusortho.com Product Portfolio Consensus Knee Systems Consensus Hip Systems Product Portfolio
More informationProximal Humerus surgical technique
Proximal Humerus surgical technique Proximal Humerus surgical technique MUTARS was developed in co-operation with Prof. Dr. W. Winkelmann, and Prof. Dr. G. Gosheger, Clinic and Polyclinic for General
More informationcopyright information: MUTARS, Aida, ACS, AJS, Bicana BethaLoc, Capica, CarpoFit, Cepthar, CCI, DiaLoc, EcoFit, GenuX, GIS, LOAD SHIFT, LUMiC,
Product Portfolio copyright information: MUTARS, Aida, ACS, AJS, Bicana BethaLoc, Capica, CarpoFit, Cepthar, CCI, DiaLoc, EcoFit, GenuX, GIS, LOAD SHIFT, LUMiC, implavit, implafix, implacross and implatan
More informationTaperFit. Cemented Femoral Stem Product rationale
TaperFit Cemented Femoral Stem Product rationale TaperFit Design History Function TaperFit cemented femoral stems have been in use for over 17 years and are clinically proven to produce excellent results
More informationReCap Product Rationale
ReCap Product Rationale A Complete resurfacing system designe engineering principles, tried and tested m clinically proven fixation methods Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales
More informationProximal Femur surgical technique
Proximal Femur surgical technique Proximal Femur surgical technique MUTARS was developed in co-operation with Prof. Dr. W. Winkelmann (former director) and Prof. Dr. G. Gosheger (director), Clinic and
More informationpact SYSTEM Surgical Technique HEMISPHERICAL CEMENTLESS CUP SYSTEM MULTI-HOLE & RIM-HOLE Hip Knee Spine Navigation
pact SYSTEM HEMISPHERICAL CEMENTLESS CUP SYSTEM MULTI-HOLE & RIM-HOLE Surgical Technique Hip Knee Spine Navigation Mpact Surgical Technique Hip Knee Spine Navigation PREFACE The Mpact Multi-hole and the
More informationInstructions for Use
Instructions for Use Non Cemented Stem without Coating Legend of Symbols Use on Packages Number in the Catalogue; Sterile Product Sterilized by Gamma Radiation; Manufacturing Date; Batch Number; Expiration
More informationScan Bi-Polar 22/28. Operative Technique
Scan Bi-Polar 22/28 Operative Technique Disclaimer This publication and all content, artwork, photographs, names, logos and marks contained in it are protected by copyright, trademarks and other intellectual
More informationExeter. Technical Guide
Exeter Technical Guide Exeter Hip System Anatomic Restoration The Exeter hip system allows interoperative changes in offset, leg length and version, all independent of one another. This flexibility facilitates
More informationOperations included in the National Joint Registry (NJR) Quick links, go to: Hips > Knees > Ankles > Elbows > Shoulders > Trauma >
Operations included in the National Joint Registry (NJR) Quick links, go to: Hips > Knees > Ankles > Elbows > Shoulders > Trauma > Version 5 December 2013 1 Version control Version number Date Amendments
More informationDual Mobility System Evaluation surgical technique
Trinity Dual Mobility System Evaluation surgical technique Contents Operative summary 4 Overview 5 Operative technique 6 1. Acetabular reaming 6 Reamer guide 6 2. Acetabular shell trial 6 3. Acetabular
More informationDual Mobility System Surgical technique
Trinity Dual Mobility System Surgical technique 2 Contents Operative summary 4 Overview 5 Operative technique 6 1. Acetabular reaming 6 Reamer guide 6 2. Acetabular shell trial 7 3. Acetabular shell implantation
More informationHard Implants. Lecture #13
Hard Implants Lecture #13 Refs: 1. Park, J. B. and Bronzino, J. D., eds., Biomaterials: Principles and Applications. CRC Press, Boca Raton, FL, 2003. 2. Park, J. B., Biomaterials Science and Engineering.
More informationManza Cup HA SURGICAL TECHNIQUE.
1 PRE-OPERATIVE PLANNING. Preoperative assessment of the appropriate size and position of the acetabular component will provide intraoperative guidance for acetabular reaming. To determine the acetabluar
More informationRM Philosophy Innovation based on clinical evidence.
RM Philosophy Innovation based on clinical evidence RM Philosophy Innovation based on clinical evidence Design 1973 RM Classic Cup First uncoated RM Classic Cup out of Polyacetal was inserted by E. Morscher
More informationAVANTEON. Operative Technique & Catalogue Information AVANTEON
AVANTEON Operative Technique & Catalogue Information AVANTEON H I P S Y S T E M Pre-operative Planning The overall aim of pre-operative planning is to establish anatomical data from the patient to guide
More informationThe Modular Knee System GenuX MK Revision Knee
The Modular Knee System GenuX MK Revision Knee Surgical Technique GenuX MK Revision Knee Surgical Technique Table of content Preoperative Planning...5 System Overview...6 Compatibility Matrix...7 Surgical
More informationMetaFix. Cementless Total Hip Replacement Surgical technique
Cementless Total Hip Replacement Surgical technique Contents Operative summary Acetabular preparation Pre-operative templating Femoral neck osteotomy Femoral canal preparation Femoral punch Tapered IM
More informationRegenerex Porous Titanium Construct. Knees Hips Extremities Cement and Accessories PMI Trauma Technology
Regenerex Porous Titanium Construct Knees Hips Extremities Cement and Accessories PMI Trauma Technology One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon provide personalized
More informationSurgical procedure. METS SMILES Total Knee Replacement
Surgical procedure METS SMILES Total Knee Replacement Surgical Procedure Contents 1.0 2.0 3.0 4.0 Device information 2 3 1.1 Product overview 1.2 Indications 1.3 Absolute contra-indications 1.4 Relative
More informationHip Resurfacing System
Hip Resurfacing System The Arthrosurface HemiCAP Hip Hemiarthroplasty System restores the articular surface geometry of the femoral head and preserves functional structures using an innovative 3 dimensional
More informationEncina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA
Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA 94065 info@stinsonortho.com www.stinsonortho.com Table of Contents Introduction 3 Features 4 Surgical Technique 5 Preoperative
More informationDual Articular.
Dual Articular 2000 www.biomet.co.uk D e s i g n R a t i o n a l e The Dual Articular Knee has been in use since 1991 and offers a flexible reconstructive solution for total knee surgery; for both revision
More informationCAUTION: Ceramic liners are not approved for use in the United States.
Total Hip Prostheses, Self-Centering Hip Prostheses and Hemi-Hip Prostheses IMPORTANT: This essential product information sheet does not include all of the information necessary for selection and use of
More informationSURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS
SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS INTRODUCTION The Summit Tapered Hip System s comprehensive set of implants and instruments
More informationWhat Are Hip and Knee Replacement Implants Made Of?
What Are Hip and Knee Replacement Implants Made Of? Hip and knee replacement surgery involve replacing the worn-out bone and cartilage lining your hip or knee joint with new implants that are composed
More informationLubinus Classic Plus Hip Prosthesis System
Lubinus Classic Plus Hip Prosthesis System Presented by: WALDEMAR LINK GmbH & Co. KG Barkhausenweg 10 22339 Hamburg, Germany P. O. Box 63 05 52 22315 Hamburg, Germany Tel.: +49 40 53995-0 Fax: +49 40 5386929
More informationCannulated Screw System. Product Overview
Cannulated Screw System Product Overview Acumed Cannulated Screw System The Acumed Cannulated Screw System consists of screws, washers, and instruments and is intended for fixation of fractures, fusions,
More informationDePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN USA Tel: +1 (800) Fax: +1 (574)
References 1. Sanchez-Sotelo J, Haidukewych GJ, Boberg CJ. Hospital Cost of Dislocation After Primary Total Hip Arthroplasty. J Bone Joint Surg. 2006;88A:290-294. 2. Brodner W, Grübl A, Jankovsky R, Meisinger
More informationRef. Number Ti.P.S. + HA. Ref. Number Ti. Plasma Spray
Section of Acetabular Implants uncemented Press fit Cup, uncemented Pressfitpfannen, unzementiert Cotyle press-fit, non-cimentée Indication : In principal for all forms of arthrosis, advance wear and tear
More informationKnee Replacement Implants
Knee Replacement Implants During knee replacement surgery, an orthopaedic surgeon will resurface your damaged knee with artificial components, called implants. There are many different types of implants.
More informationEndo-Model Unicondylar Sled Prosthesis. with MITUS Instrument Set. Implants & Instruments
Endo-Model Unicondylar Sled Prosthesis with MITUS Instrument Set Implants & Presented by: Waldemar Link GmbH & Co. KG Barkhausenweg 10 22339 Hamburg, Germany P.O. Box 63 05 52 22315 Hamburg, Germany Tel.:
More informationHELIOS h i p s y s t e m
HELIOS h i p s y s t e m Design The Helios stem is a highly polished, High Nitrogen Stainless Steel (ISO5832-9) dual tapered cemented stem. The design of the stem is based on the clinically lly successful
More informationSurgical Technique. Cup System
Surgical Technique Cup System INDICATIONS AND USAGE Indications for the use of the CS2 ACETABULAR CUP SYSTEM must be carefully considered with respect to the patient s entire evaluation and alternative
More informationRS Arthrodesis Implant surgical technique
RS Arthrodesis Implant surgical technique RS Arthrodesis implant surgical technique MUTARS was developed in co-operation with Prof. Dr. W. Winkelmann (former director) and Prof. Dr. G. Gosheger (director),
More informationDHS Plate 135º. DHS Platte 135º
Section of hip fixation plate compression system DHS Plate 3º DHS Platte 3º Plaque de DHS 3º Indication : The compression hip plate is primarly indicated for intertrochanteric fractures. However, it can
More informationISO INTERNATIONAL STANDARD. Non-active surgical implants Joint replacement implants Particular requirements
INTERNATIONAL STANDARD ISO 21534 Second edition 2007-10-01 Non-active surgical implants Joint replacement implants Particular requirements Implants chirurgicaux non actifs Implants de remplacement d'articulation
More informationNational Joint Replacement Registry. Lay Summary 2015 Annual Report Hip and Knee Replacement
National Joint Replacement Registry Lay Summary 2015 Annual Report Hip and Knee Replacement SUPPLEMENTARY REPORT 2015 TABLE OF CONTENTS Introduction... 1 A brief history of the Registry origins... 1 The
More informationSurgical Technique. *smith&nephew POLARSTEM Cementless and Cemented Stem System
Surgical Technique *smith&nephew POLARSTEM Cementless and Cemented Stem System 2 POLARSTEM Contents Introduction... 4 Indications... 5 Contraindications... 5 Case Studies... 6 Preoperative Planning...
More informationDieter Marquardt Medizintechnik GmbH 08 Cannulated Screws
Cannulated Screws Product Name: Cannulated Screw Ø 3.5 Screw diameter: 3.5 mm Core diameter: 2.5 mm Head diameter: 5.0 mm Thread: short or full Cannulation: 1.35 mm Inner hexagon: 2.5 mm Screw Length:
More informationOptimizing function Maximizing survivorship Accelerating recovery
Surgical Technique Optimizing Function Maximizing Survivorship Accelerating Recovery The company believes in an approach to patient treatment that places equal importance on: Optimizing function Maximizing
More informationSurgical procedure. METS Modular Proximal Femur
Surgical procedure METS Modular Proximal Femur Surgical Procedure Contents 1.0 2.0 3.0 4.0 5.0 Device information 2 3 1.1 Product overview 1.2 Indications 1.3 Absolute contra-indications 1.4 Relative
More informationTHE NATURAL FIT. Surgical Technique. Hip Knee Spine Navigation
THE NATURAL FIT Surgical Technique Hip Knee Spine Navigation MiniMAX Surgical Technique Hip Knee Spine Navigation INTRODUCTION The MiniMAX TM is a cementless anatomic stem available in 9 right sizes and
More informationThe proven, simple solution. CPT 12/14 Hip System
The proven, simple solution CPT 12/14 Hip System Primary CPT Hip The proven, simple solution 5mm The collarless, polished, doubletaper design concept used in the CPT 12/14 Hip System has proven itself
More information