COMMERCIAL LEAFLET. Inventor of dual mobility. in Novae. range

Size: px
Start display at page:

Download "COMMERCIAL LEAFLET. Inventor of dual mobility. in Novae. range"

Transcription

1 COMMERCIAL LEAFLET Inventor of dual mobility Novae range in 1975

2 Novae range Novae concept SUNFIT TH The dual mobility concept was invented in 1975 by Professor Gilles BOUSQUET and the engineer André RAMBERT, the founder of SERF. The main focus of their work was to increase joint stability and reduce surface wear. The system consists of a thin metal back cup into which a mobile polyethylene insert is fitted. This retentive insert, the distinctive geometry of which was patented in 1975, articulates around the prosthetic head. The result is a very stable implant that reproduces the natural anatomy and movement of the joint far more accurately than any other hip replacement system. The dual mobility concept, which was considered ground-breaking at the time, has now been widely adopted. NOVAE E TH COPTOS TH STICK Bibliography A bibliography of publications covering more than thirty years of clinical experience is available on request. A cup holder MIS-adapted is available.

3 Internal Geometry of the Metal-back shell + 3 mm High quality internal surface geometry and polish. The 3-mm cylindrical extension plays a key role in prosthesis stability, considerably increasing the dislocation distance. External Geometry of the Metal-back shell front The front of the cup features three 120 areas. A ridged pattern is arranged around three slightly higher (by several tenths of a millimetre) points, intented to be positioned opposite to the illium, pubis and ischium. The series of ridges between these three higher points gradually decreases to create a perfect pressfit. The trough of these structures gives the cup s reference diameter. External Geometry of the Metal-back shell from the equator to the pole area + 3mm Volume, the thickness and height of which varies depending on the size of the cup, is added to the equatorial area by numerous ridges (circular spur-shaped grooves broken up by recesses, the base of which gives the cup s reference diameter). The gradual flattening out of the pole around a wide radius (up to 0.5mm) helps to absorb stresses from the base of the cup at the time of final impaction. External Geometry of the Metal-back shell between the equator and the pole area The intermediary area between the pressfit and the pole consists of grooves which contribute to secondary stability once bone in-growth has filled them. The external surface of NOVAE TH cups is coated with both a titanium spray and a layer of hydroxyapatite. This dual coating strengthens its primary fixation stability and increases longevity. HAP 60µ Ti 150µ Cup

4 Novae References SUNFIT TH Non cemented modular (without insert), press-fit bilayer coating (titanium and hydroxyapatite). NOVAE E TH RM SUNFIT TH 43* RM SUNFIT TH 45 RM SUNFIT TH RM SUNFIT TH RM SUNFIT TH RM SUNFIT TH RM SUNFIT TH RM SUNFIT TH RM SUNFIT TH RM SUNFIT TH RM SUNFIT TH RM SUNFIT TH Non cemented modular (without insert). Stainless steel ti + hap coating. A fixing flange. CIE RM NOVAE E 41 TH* CI E RM NOVAE E 43 TH* RM *CI 43/22,2 E NOVAE E 45 TH RM CI 45/22,2 E RM NOVAE E TH RM CI /22,2 E RM NOVAE E TH RM CI /22,2 E RM NOVAE E TH RM CI /22,2 E RM NOVAE E TH RM CI /22,2 E RM NOVAE E TH RM CI /22,2 E RM NOVAE E TH RM CI /22,2 E RM NOVAE E TH RM CI /22,2 E RM NOVAE E TH RM UHMWPE MOBILE INSERT mm diameter. PE (ISO ) RM CI /22,2 E NOVAE E TH* RM *CI /22,2 E RM NOVAE E TH* RM *CI /22,2 E RM NOVAE E TH* RM *CI /22,2 E RM NOVAE E TH* RM *CI /22,2 E UHMWPE MOBILE INSERT. 28 mm diameter. PE (ISO ) RM COPTOS 45 TH RM COPTOS TH RM COPTOS TH RM COPTOS TH NOVAE STICK 43* RM NOVAE STICK 45 RM NOVAE STICK RM NOVAE STICK RM NOVAE STICK RM NOVAE STICK NOVAE STICK RM NOVAE STICK RM NOVAE STICK RM COPTOS TH RM RM COPTOS TH RM RM COPTOS TH* RM COPTOS TH* RM COPTOS TH * On specific request Cemented modular (without insert) RM RM RM COPTOS TH RM COPTOS TH 2 flanges and a hook RM CI /28 E RM CI /28 E RM CI /28 E RM CI /28 E RM CI /28 E RM CI /28 E RM CI /28 E RM CI /28 E RM *CI /28 E RM *CI /28 E RM *CI /28 E RM *CI /28 E STICK RM COPTOS 43 TH* Non cemented reconstruction (without insert). ti + hap coating *CI 41/22,2 E RM CI E COPTOS TH RM RM COPTOS TH* RM COPTOS TH* Self-tapping cortical screws, 3.5mm hex diameter 5, RM0013 VCI 5 X 20 RM0015 VCI 5 X 25 RM0017 VCI 5 X 30 RM0019 VCI 5 X 35 RM0021 VCI 5 X 40 RM0046 VCI 5 X 45 RM0031 VCI 5 X 50 RM00 VCI 5 X RM0041 VCI 5 X 60 NOVAE STICK RM0048 VCI 5 X NOVAE STICK * RM00 VCI 5 X 70

5 Novae Range Novae SunFit TH Novae Coptos TH Novae Stick Novae Evolution TH Novae K E Novae Arm 22.2 mm insert 28 mm insert 32 mm insert Materials Left Right Made to measure Metalback shells Stainless steel X18M25 ISO Cross Novae K E Stainless steel X18M25 - ISO Spacers PMMA - ISO 5833 Coatings Titanium spray Ti AJTM F 1580 HA ISO Insert UHMWPE ISO Cortical screws diameter 5mm Stainless steel X18M25 ISO

6 ED VERSION ANGLAISE SFRADT A 85 avenue des Bruyères - 1 Décines Cedex - FRANCE Tél Fax serf@serf.fr ISO SERF / Décines - France

DUAL MOBILITY CUP, CEMENTED OR CEMENTLESS

DUAL MOBILITY CUP, CEMENTED OR CEMENTLESS HIP Documentation DUAL MOBILITY CUP, CEMENTED OR CEMENTLESS >>DUAL MOBILITY ACETABULAR CUPS Dual mobility acetabular cup P r Gilles Bousquet invented the concept of dual mobility more than thirty years

More information

*smith&nephew POLARCUP Dual Mobility System. Product Information

*smith&nephew POLARCUP Dual Mobility System. Product Information Product Information *smith&nephew POLARCUP Dual Mobility System Dual Mobility 30 Years of Clinical Experience Concept combining an extended ROM, a low rate of dislocation and unexpectedly limited wear.

More information

Dual Mobility Cups. Kris Govaers, MD, PhD Dendermonde Belgium

Dual Mobility Cups. Kris Govaers, MD, PhD Dendermonde Belgium Dual Mobility Cups Kris Govaers, MD, PhD Dendermonde Belgium Introduction Indications Limitations Conclusions All good things in life come from France Gilles Bousquet 1979 + Rambert (SERF) Inventions Bousquet

More information

Product Information. *smith&nephew POLARCUP Dual Mobility System

Product Information. *smith&nephew POLARCUP Dual Mobility System APPLYING SCIENCE TO MOBILITY Combined with VERILAST Technology for unmatched performance Product Information *smith&nephew POLARCUP Dual Mobility System APPLYING SCIENCE TO MOBILITY Combined with VERILAST

More information

*smith&nephew EP-FIT PLUS Cementless Press-Fit Cup System. Product Information

*smith&nephew EP-FIT PLUS Cementless Press-Fit Cup System. Product Information Product Information *smith&nephew EP-FIT PLUS Cementless Press-Fit Cup System EP-FIT PLUS Press-Fit Acetabular Cup System A new generation in press-fit cup technology Proven anchoring concept in combination

More information

Cemented femoral stem - type CSC

Cemented femoral stem - type CSC Cemented femoral stem - type CSC Cemented Femoral Hip Joint Components ARTHROPLASTY Implant Description Preface The cemented femoral stem type CSC with centralizer was designed using the latest knowledge

More information

RM Philosophy Innovation based on clinical evidence.

RM Philosophy Innovation based on clinical evidence. RM Philosophy Innovation based on clinical evidence RM Philosophy Innovation based on clinical evidence Design 1973 RM Classic Cup First uncoated RM Classic Cup out of Polyacetal was inserted by E. Morscher

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD ISO 7206-12 First edition 2016-10-01 Implants for surgery Partial and total hip joint prostheses Part 12: Deformation test method for acetabular shells Implants chirurgicaux Prothèses

More information

Individual oncological implants

Individual oncological implants Individual oncological implants Catalogue - individual oncological implants ONCOLOGICAL Materials for implants List of materials MATERIAL ISO ČSN DIN ASTM Stainless steel 5832-1 17350 výběr 17 443 W.Nr.

More information

Implants for surgery Partial and total hip joint prostheses. Part 12: Deformation test method for acetabular shells

Implants for surgery Partial and total hip joint prostheses. Part 12: Deformation test method for acetabular shells INTERNATIONAL STANDARD ISO 7206-12 First edition 2016-10-01 Implants for surgery Partial and total hip joint prostheses Part 12: Deformation test method for acetabular shells Implants chirurgicaux Prothèses

More information

Revision systems. Catalogue - revision implants ARTHROPLASTY

Revision systems. Catalogue - revision implants ARTHROPLASTY evision systems Catalogue revision implants ATHOPASTY Material for implants Contens ist of materials MATEIA ISO DIN ASTM Stainless steel Wrought high nitrogen stainless steel Unalloyed titanium 321 329

More information

Optimum implant geometry

Optimum implant geometry Design Rationale Optimum implant geometry Extending proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available

More information

Consistency in U2 Knee System over Time

Consistency in U2 Knee System over Time U2 TM Knee System Consistency in U2 Knee System over Time Share the same femoral profile of all types allow inter-changibility Uniform AP/ML dimensions in all tibial components enhance intraoperative flexibility

More information

Cementless femoral stem type SF

Cementless femoral stem type SF Cementless femoral stem type SF Cementless Femoral Hip Joint Components ARTHROPLASTY Implant Description Surgical Technique Instrumentation Set Catalogue Preface The cementless stem of a total hip joint

More information

Optimizing function Maximizing survivorship Accelerating recovery

Optimizing function Maximizing survivorship Accelerating recovery Surgical Technique Optimizing Function Maximizing Survivorship Accelerating Recovery The company believes in an approach to patient treatment that places equal importance on: Optimizing function Maximizing

More information

Electron Beam Melting EBM

Electron Beam Melting EBM Cup Fixa Cup Fixa The uncemented cup with equatorial primary press-fit fixation is considered to be the best solution for prosthesis surgery of the acetabulum. In addition to exploiting this safe mechanical

More information

CONSENSUS ORTHOPEDICS INC.

CONSENSUS ORTHOPEDICS INC. CONSENSUS ORTHOPEDICS INC. CONSENSUS HIP SYSTEMS Instructions for Use (IFU) IMPORTANT INFORMATION FOR SURGEON: PLEASE READ PRIOR TO IMPLANTING THIS DEVICE IN A CLINICAL SETTING. THE SURGEON SHOULD BE FAMILIAR

More information

Enhancing stability and increasing range of motion. Metasul LDH Large Diameter Head

Enhancing stability and increasing range of motion. Metasul LDH Large Diameter Head Enhancing stability and increasing range of motion Metasul LDH Large Diameter Head The Metasul large diameter head technology is the result of in-depth research, development and clinical experience that

More information

Optimum implant geometry

Optimum implant geometry Design Rationale Optimum implant geometry Extending the proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available

More information

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique Enhanced Stability Constrained Liners Design Rationale Surgical Technique The Pinnacle Acetabular Cup System was designed to maximize the number of options available to the surgeon, and provide those options

More information

ReCap Product Rationale

ReCap Product Rationale ReCap Product Rationale A Complete resurfacing system designe engineering principles, tried and tested m clinically proven fixation methods Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales

More information

Optimum implant geometry

Optimum implant geometry Surgical Technique Optimum implant geometry Extending proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available

More information

Wear 268 (2010) Contents lists available at ScienceDirect. Wear. journal homepage:

Wear 268 (2010) Contents lists available at ScienceDirect. Wear. journal homepage: Wear 268 (2010) 617 621 Contents lists available at ScienceDirect Wear journal homepage: www.elsevier.com/locate/wear Wear comparison between a dual mobility total hip prosthesis and a typical modular

More information

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE CONTENTS Introduction 2 Pre-operative Planning 4 Determining the Centre of Rotation 5 Surgical Technique 6 Acetabular Preparation

More information

Uniglide. Unicompartmental Knee Replacement Product overview

Uniglide. Unicompartmental Knee Replacement Product overview Uniglide Unicompartmental Knee Replacement Product overview Uniglide History Technology Versatility Uniglide is a clinically proven highly congruent, triple radius unicompartmental knee system, offering

More information

Hip Implants. Hip Implants. 6 Your partner for implants and trauma products. Euromed Implants GmbH General Catalogue

Hip Implants. Hip Implants. 6 Your partner for implants and trauma products. Euromed Implants GmbH General Catalogue 6 Modular Straight Cemented Stem The modular straight cemented stem hip prosthesis is designed to be used as a primary and revision total hip. The 4 stem sizes allow accurate matching of prosthesis to

More information

Duraloc CONSTRAINED LINER

Duraloc CONSTRAINED LINER SURGICAL TECHNIQUE Duraloc CONSTRAINED LINER A COMPREHENSIVE ACETABULAR REVISION SYSTEM DURALOC CONSTRAINED LINER Introduction Dislocation is the most common postoperative complication in total hip reconstruction.

More information

TOTAL HIP REPLACEMENT:

TOTAL HIP REPLACEMENT: THR Prosthesis Design TOTAL HIP REPLACEMENT: PROSTHESIS DESIGN FEATURES JESS JOHNSTON & MELINDA ZIETH History of Hip Prosthesis Joint Replacement Registry Implant Design Technology & Future History and

More information

PINNACLE REVISION CUP SYSTEM

PINNACLE REVISION CUP SYSTEM PINNACLE REVISION CUP SYSTEM This publication is not intended for distribution in the USA. DESIGN RATIONALE FLEXIBILITY. PRECISION. CONFIDENCE. DePuy Synthes Joint Reconstruction is proud to offer the

More information

ANATOMIC Fixed Bearing Total Knee System Posterior Stabilised Version Cemented or Cementless Options

ANATOMIC Fixed Bearing Total Knee System Posterior Stabilised Version Cemented or Cementless Options ANATOMIC Fixed Bearing Total Knee System Posterior Stabilised Version Cemented or Cementless Options ANATOMIC l Anatomic femoral component design based on a study of 420 knees digitised using the AMPLIVISION

More information

Allofit /Allofit -S Alloclassic Acetabular Cup System

Allofit /Allofit -S Alloclassic Acetabular Cup System Allofit /Allofit -S Alloclassic Acetabular Cup System Product Information Convincing Primary Stability The Allofit acetabular cup was developed in 1993. The goal was to create a reliable implant that was

More information

Scan Bi-Polar 22/28. Operative Technique

Scan Bi-Polar 22/28. Operative Technique Scan Bi-Polar 22/28 Operative Technique Disclaimer This publication and all content, artwork, photographs, names, logos and marks contained in it are protected by copyright, trademarks and other intellectual

More information

Dual Mobility System Surgical technique

Dual Mobility System Surgical technique Trinity Dual Mobility System Surgical technique 2 Contents Operative summary 4 Overview 5 Operative technique 6 1. Acetabular reaming 6 Reamer guide 6 2. Acetabular shell trial 7 3. Acetabular shell implantation

More information

Section of Modular Hip Prostheses cemented. TMC-3 Modular Hip Prosthesis, cemented. TMC-3 Modular Hüftprothese, zementiert

Section of Modular Hip Prostheses cemented. TMC-3 Modular Hip Prosthesis, cemented. TMC-3 Modular Hüftprothese, zementiert Section of Modular Hip Prostheses cemented TMC-3 Modular Hip Prosthesis, cemented TMC-3 Modular Hüftprothese, zementiert Prothèse de hanche modulaire TMC-3, cimentée Indication : The TMC-3 Modular hip

More information

A Patient s Guide to Artificial Cervical Disc Replacement

A Patient s Guide to Artificial Cervical Disc Replacement A Patient s Guide to Artificial Cervical Disc Replacement Each year, hundreds of thousands of adults are diagnosed with Cervical Disc Degeneration, an upper spine condition that can cause pain and numbness

More information

Principles of acetabular fixation in primary and revision hip arthroplasty Piotr Wojciechowski, Damian Kusz, Anna WAGNER

Principles of acetabular fixation in primary and revision hip arthroplasty Piotr Wojciechowski, Damian Kusz, Anna WAGNER Principles of acetabular fixation in primary and revision hip arthroplasty Piotr Wojciechowski, Damian Kusz, Anna WAGNER Department of Orthopedics and Traumatology Medical University of Silesia Head of

More information

Luminus Flex Total Knee System (Fixed Type) The Innovative Technology for Knee Replacement

Luminus Flex Total Knee System (Fixed Type) The Innovative Technology for Knee Replacement Luminus Flex Total Knee System (Fixed Type) The Innovative Technology for Knee Replacement Intro The Luminus-Flex Total Knee system takes its name from the English word "Luminous" An adjective meaning

More information

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique ESC Enhanced Stability Liners Design Rationale & Surgical Technique Choice Without Compromise DePuy Synthes PINNACLE Hip Solutions are designed with a wide range of acetabular cup options, biological and

More information

Product EFFICIENT MOBILITY. FlexitSystem. Opening Wedge High Tibial Osteotomy Solution

Product EFFICIENT MOBILITY. FlexitSystem. Opening Wedge High Tibial Osteotomy Solution FlexitSystem EFFICIENT MOBILITY Product FlexitSystem Opening Wedge High Tibial Osteotomy Solution For a quick and comfortable FlexitSystem AN EASY AND SMART OPENING WEDGE HIGH TIBIAL OSTEOTOMY SOLUTION

More information

PACH PLATE 2 OR 4 HOLE FIXATION

PACH PLATE 2 OR 4 HOLE FIXATION 2 OR 4 HOLE FIXATION The Science of Fusion PACH_v6.indd 1 6/03/2015 7:10 am PACH Plate Design Rationale The PACH Plate has been designed to be used as an anterior or lateral fixation plate for the thoracolumbar,

More information

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter Design Philosophy Cementless Stems of 12/14 Taper Stem Length Neck shaft Angle STEM-N3 STEM-N4 STEM-N5 STEM-N6 STEM-N7 STEM-N8 STEM-N9 123 mm 125 mm 130 mm 135 mm 140 mm 145 mm 150 mm 132 Cement Polished

More information

The Leader in Orthopaedic Innovation

The Leader in Orthopaedic Innovation The Leader in Orthopaedic Innovation Wright is a leading international manufacturer and distributor of superior, easy to use, and innovative orthopaedic implants and instrumentation. For over 50 years,

More information

Merete BioBall The Innovative Hip Endoprosthesis Head Adapter System

Merete BioBall The Innovative Hip Endoprosthesis Head Adapter System Merete the «BioBall Company» You are better off with BioBall Your Indispensable Assistant in Hip Arthroplasties. Merete BioBall The Innovative Hip Endoprosthesis Head Adapter System 2 BioBall System Merete

More information

PLR. Proximal Loading Revision Hip System

PLR. Proximal Loading Revision Hip System PLR Proximal Loading Revision Hip System The PLR splined revision stem is designed to recreate the natural stresses in the revised femur, where proximal bone may be compromised. PLR Hip System Design Considerations

More information

PROCOTYL E Acetabular Cup System. Modular to Fit Patient s Anatomy. Versatile for Revisions.

PROCOTYL E Acetabular Cup System. Modular to Fit Patient s Anatomy. Versatile for Revisions. PROCOTYL E Acetabular Cup System Modular to Fit Patient s Anatomy. Versatile for Revisions. TM PROCOTYL E Shell is a revision modular shell manufactured from titanium alloy. It is ovoid-shaped, with a

More information

Bone Preservation Stem

Bone Preservation Stem TRI-LOCK Bone Preservation Stem Featuring GRIPTION Coating Surgical Technique Implant Geometry Extending the TRI-LOCK Stem heritage The original TRI-LOCK Stem was introduced in 1981. This implant was

More information

Bi-Polar 22.2mm & 28mm System - Operative technique

Bi-Polar 22.2mm & 28mm System - Operative technique Disclaimer Biomet UK Ltd, as the manufacturer of this device, does not practice medicine and does not recommend any particular surgical technique for use on a specific patient. The surgeon who performs

More information

Reaching new heights. Comprehensive. Efficient. Simple.

Reaching new heights. Comprehensive. Efficient. Simple. Reaching new heights Comprehensive. Efficient. Simple. Various acetabular cup choices Compatible with the different head and liner options including VERILAST Technology Reach for proven OR efficient Instrumentation

More information

Implants for primary surgery

Implants for primary surgery Implants for primary surgery Catalogue - primary implants THOPSTY Hip Knee Shoulder Finger ist of materials MTEI ISO ČSN DIN STM Stainless steel Wrought high nitrogen stainless steel Unalloyed titanium

More information

Aesculap Orthopaedics Excia. Hip Stem

Aesculap Orthopaedics Excia. Hip Stem Aesculap Orthopaedics Excia Hip Stem Excia specifically addresses three aspects of a modern hip stem. The prosthesis design, implantation technique, and implant surface form the foundation for success

More information

RECOVERY. P r o t r u s i o

RECOVERY. P r o t r u s i o RECOVERY P r o t r u s i o TM C a g e RECOVERY P r o t r u s i o TM C a g e Design Features Revision acetabular surgery is a major challenge facing today s total joint revision surgeon. Failed endo/bi-polars,

More information

Dentoalveolar Bone Fixation System. Bone fixation sets for the office.

Dentoalveolar Bone Fixation System. Bone fixation sets for the office. Dentoalveolar Bone Fixation System. Bone fixation sets for the office. Compact Modular Customized Dentoalveolar Bone Fixation System. Bone fixation sets for the office. Who we are Synthes is a global medical

More information

Surgical procedure. METS Coned Hemi-Pelvis

Surgical procedure. METS Coned Hemi-Pelvis Surgical procedure METS Coned Hemi-Pelvis Surgical Procedure Contents 1.0 2.0 3.0 4.0 5.0 Product overview 2 1.1 Indications 1.2 Absolute contra-indications 1.3 Relative contra-indications 1.4 Capabilities

More information

Ref. Number Ti.P.S. + HA. Ref. Number Ti. Plasma Spray

Ref. Number Ti.P.S. + HA. Ref. Number Ti. Plasma Spray Section of Acetabular Implants uncemented Press fit Cup, uncemented Pressfitpfannen, unzementiert Cotyle press-fit, non-cimentée Indication : In principal for all forms of arthrosis, advance wear and tear

More information

Positioning Sleeve Surgical Technique

Positioning Sleeve Surgical Technique Positioning Sleeve Surgical Technique Surgical Technique The Comprehensive Fracture System offers a unique tool to evaluate and re-establish humeral height, which can be critical to restoring proper biomechanics

More information

Dual Mobility System Evaluation surgical technique

Dual Mobility System Evaluation surgical technique Trinity Dual Mobility System Evaluation surgical technique Contents Operative summary 4 Overview 5 Operative technique 6 1. Acetabular reaming 6 Reamer guide 6 2. Acetabular shell trial 6 3. Acetabular

More information

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY E C H E L O N P R I M A R Y H I P S Y S T E M P R O D U C T R A T I O N A L E ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY Echelon Primary Total Hip System HIGH OFFSET STANDARD OFFSET Cementless

More information

JOINT RULER. Surgical Technique For Knee Joint JRReplacement

JOINT RULER. Surgical Technique For Knee Joint JRReplacement JR JOINT RULER Surgical Technique For Knee Joint JRReplacement INTRODUCTION The Joint Ruler * is designed to help reduce the incidence of flexion, extension, and patellofemoral joint problems by allowing

More information

Efficacy Innovation ABG II. Brochure. Surgical Protocol. Cemented Stem

Efficacy Innovation ABG II. Brochure. Surgical Protocol. Cemented Stem Efficacy Innovation ABG II Cemented Stem Brochure Surgical Protocol 2 The ABG Hip System The ABG hip implant range has been progressively extended and enhanced over the past years, harnessing extensive

More information

External Hexagon Hybrid Implants. External Hexagon Hybrid Implants. Versatility.

External Hexagon Hybrid Implants. External Hexagon Hybrid Implants. Versatility. External Hexagon Hybrid Implants Versatility. www.pibranemark.com HEX-S Solid Enhanced Macrogeometry Easy, Safe and Simplified installation (!). Special Conical Drills have the same geometry of Hybrid

More information

PRODUCT SCHEDULE FOR CERTIFICATE CE JRI ORTHOPAEDICS LIMITED

PRODUCT SCHEDULE FOR CERTIFICATE CE JRI ORTHOPAEDICS LIMITED HIP STEM (Class III) Active Stem Active H-AC Stem / 09mm - 16mm Cemented Hemiarthroplasty (formally LOL 127) Cemented Hemiarthroplasty Stem / X-X-Small - Large Cemented Hemiarthroplasty Stem - Long / Small

More information

GENERIC, LOGIC, INTEGRALE TO.H.GB.011/1.0

GENERIC, LOGIC, INTEGRALE TO.H.GB.011/1.0 Surgical technique mechanical instrumentation GENERIC, LOGIC, INTEGRALE TO.H.GB.011/1.0 2 Pre-surgical planning By means of radiological assessment and templates, it is possible to: - determine the position

More information

International Journal of Engineering Research and Development e A Mathematical Model to Calculate Contact Stresses In Artificial Human Hip Joint

International Journal of Engineering Research and Development e A Mathematical Model to Calculate Contact Stresses In Artificial Human Hip Joint International Journal of Engineering Research and Development e-issn: 2278-067X, p-issn: 2278-800X, www.ijerd.com Volume 6, Issue 12 (May 2013), PP. 119-123 A Mathematical Model to Calculate Contact Stresses

More information

MicroSeal Total Hip Acetabular System. Like Nothing Else

MicroSeal Total Hip Acetabular System. Like Nothing Else MicroSeal Total Hip Acetabular System Like Nothing Else Like Nothing Else Unique Patented Sealing and Locking Design The MicroSeal design features: Locking/Sealing mechanisms work together to minimize

More information

PRODUCT CATALOG. Since 1985» Simple. Predictable. Profitable.

PRODUCT CATALOG. Since 1985» Simple. Predictable. Profitable. PRODUCT CATALOG Since 1985» Simple. Predictable. Profitable. 2014 IMPLANTS HEALING PLUG INSERTERS COLLAGEN PRODUCTS 3.0mm Well Integra-CP Part No. DIAMETER LENGTH Price 345-306 4.5mm mm $280.00 345-308

More information

Furlong H-A.C. THR System

Furlong H-A.C. THR System Important Information Please read prior to use in a clinical setting. The Surgeon should be familiar with the operative technique. Caution Federal (U.S.A) law restricts this device to sale by or on the

More information

MetaFix Cementless Total Hip Replacement Product overview

MetaFix Cementless Total Hip Replacement Product overview MetaFix Cementless Total Hip Replacement Product overview MetaFix Evolution Versatility Simplicity Founded on 20 years experience in cementless technology with a proven, world-leading stem design, MetaFix

More information

Aesculap Plasmafit. Cementless Acetabular Cup System. Aesculap Orthopaedics

Aesculap Plasmafit. Cementless Acetabular Cup System. Aesculap Orthopaedics Aesculap Plasmafit Cementless Acetabular Cup System Aesculap Orthopaedics Aesculap Plasmafit Cementless Acetabular Cup System 2 Content Plasmafit Concept 4 Plasmafit System 6 Plasmafit Surface 8 Plasmafit

More information

SURGICAL TECHNIQUE. Protrusio Cage A COMPREHENSIVE ACETABULAR REVISION SYSTEM

SURGICAL TECHNIQUE. Protrusio Cage A COMPREHENSIVE ACETABULAR REVISION SYSTEM SURGICAL TECHNIQUE Protrusio Cage A COMPREHENSIVE ACETABULAR REVISION SYSTEM Important: This essential product information does not include all of the information necessary for selection and use of a device.

More information

Surface evaluation of orthopedic hip implants marketed in Brazil

Surface evaluation of orthopedic hip implants marketed in Brazil Surface evaluation of orthopedic hip implants marketed in Brazil M.M.Souza 1, R.M. Trommer 2, M.M.Maru 2, C.R.M.Roesler 3, W.S.Barros 1, M.S. Dutra 3 1 Dimensional Metrology Laboratory, Inmetro. Brazil;

More information

Section of total knee replacement. Total Knee Replacement System. Knieendoprothesen System. Système de prothèse totale de genou

Section of total knee replacement. Total Knee Replacement System. Knieendoprothesen System. Système de prothèse totale de genou Section of total knee replacement Total Knee Replacement System Knieendoprothesen System Système de prothèse totale de genou Introduction: This knee system features great versality with its modular component

More information

*smith&nephew SBG Anatomical Hip Stem Prosthesis. Product Information

*smith&nephew SBG Anatomical Hip Stem Prosthesis. Product Information Product Information *smith&nephew SBG Anatomical Hip Stem Prosthesis For a Perfect Fit Because Anatomy Matters On account of its anatomical shape the cementless SBG stem, which has been used successfully

More information

ARTICLE IN PRESS. Surface Oxidized Zirconium Total Hip Arthroplasty Head Damage Due to Closed Reduction. Effects on Polyethylene Wear

ARTICLE IN PRESS. Surface Oxidized Zirconium Total Hip Arthroplasty Head Damage Due to Closed Reduction. Effects on Polyethylene Wear The Journal of Arthroplasty Vol. 00 No. 0 2008 Surface Oxidized Zirconium Total Hip Arthroplasty Head Damage Due to Closed Reduction Effects on Polyethylene Wear William L. Jaffe, MD,* Eric J. Strauss,

More information

Bipolar Radial Head System

Bipolar Radial Head System Bipolar Radial Head System Katalyst Surgical Technique DESCRIPTION The Katalyst Telescoping Bipolar Radial Head implant restores the support and bearing surface of the radial head in the face of fracture,

More information

Featuring. Technology. Product Rationale

Featuring. Technology. Product Rationale Featuring Technology Product Rationale 2 Optimum implant geometry Extending proven TRI-LOCK heritage The original TRI-LOCK Stem was introduced in 1981. This implant was the first proximally coated tapered-wedge

More information

Four implants...choice of Connection. Each implant comes with Hex or Conical Connection.

Four implants...choice of Connection. Each implant comes with Hex or Conical Connection. Implant Overview Surface Treatment...Proven Surfaces All SpiralTech implants have a proven RBM (Resorbable Blast Media), SLA (sandblasted large-grit acid etched) or HA (hydroxyapatite) surface Applied

More information

Surgical Technique r5.indd 1 12/8/10 10:36 AM

Surgical Technique r5.indd 1 12/8/10 10:36 AM Surgical Technique The science of simplicity With more than 700,000 implantations and two and a half decades of clinical success, the Corail Total Hip System now has the most extensive experience with

More information

28 Surgical Technique

28 Surgical Technique Surgical Technique 10 12 14 16 18 20 22 24 28 26 Technique described by James L. Guyton, MD Campbell Clinic Memphis, Tennessee James W. Harkess, MD Campbell Clinic Memphis, Tennessee David G. LaVelle,

More information

S i m p l i c I t y, c o m f o r t, a e s t h e t i c s. axiom. The new dimension

S i m p l i c I t y, c o m f o r t, a e s t h e t i c s. axiom. The new dimension S i m p l i c I t y, c o m f o r t, a e s t h e t i c s axiom The new dimension 2 Implants by anthogyr axiom, t h e n e w g e n e r a t i o n i m p l a n t axiom characteristics represent the perfect synthesis

More information

Hype Femoral stems. Surgical technique

Hype Femoral stems. Surgical technique Hype Femoral stems Surgical technique Femoral implant Instrumentation Offset 6 mm Geometry Femoral broaches L 45 The neck length increases with each stem size. 130 (standard and offset stems) 120 (coxa

More information

Avenir Femoral Hip System

Avenir Femoral Hip System Avenir Femoral Hip System Avenir Hip System Intuitive and Reproducible During its decade of experience in the bone compaction stem market, the Avenir Hip System has helped surgeons experience flexible,

More information

Exeter. Technical Guide

Exeter. Technical Guide Exeter Technical Guide Exeter Hip System Anatomic Restoration The Exeter hip system allows interoperative changes in offset, leg length and version, all independent of one another. This flexibility facilitates

More information

Trinity. Advanced Bearing Acetabular System Surgical technique

Trinity. Advanced Bearing Acetabular System Surgical technique Advanced Bearing Acetabular System Surgical technique Contents Operative summary Introduction Pre-operative planning Acetabular preparation Acetabular reaming Reamer guide Acetabular shell trials Acetabular

More information

The proven, simple solution. CPT 12/14 Hip System

The proven, simple solution. CPT 12/14 Hip System The proven, simple solution CPT 12/14 Hip System Primary CPT Hip The proven, simple solution 5mm The collarless, polished, doubletaper design concept used in the CPT 12/14 Hip System has proven itself

More information

METAL HEMI SYSTEM

METAL HEMI SYSTEM METAL HEMI SYSTEM 152206-0 The following languages are included in this packet: English (en) Deutsch (de) Nederlands (nl) Français (fr) Español (es) Italiano (it) Português (pt) 中文 - Chinese (sch) Türkçe

More information

Surgical Technique. *smith&nephew POLARCUP Dual Mobility System

Surgical Technique. *smith&nephew POLARCUP Dual Mobility System Surgical Technique *smith&nephew POLARCUP Dual Mobility System POLARCUP Table of Contents Preface... 3 Indications... 5 Contraindications... 5 Case studies... 6 Pre-operative Planning...7 Surgical Technique...

More information

Aesculap Trilliance Triple Tapered Polished Hip Stem

Aesculap Trilliance Triple Tapered Polished Hip Stem Aesculap Trilliance Triple Tapered Polished Hip Stem Aesculap Orthopaedics Trilliance Triple Tapered Polished Hip Stem CONTENTS 2 Contents Page Trilliance Philosophy 4 Trilliance Design 6 Trilliance Implants

More information

Introduction The oval cup MEDIN is used in clinic praxis since the 1999 year. During the period of two years it has been used for more than 1000 patie

Introduction The oval cup MEDIN is used in clinic praxis since the 1999 year. During the period of two years it has been used for more than 1000 patie Surgical Technique for the Hip Joint Replacement MEDIN OVAL MO MEDIN OVAL MODULAR MOM MUDr. Ivan Landor, CSc. Introduction The oval cup MEDIN is used in clinic praxis since the 1999 year. During the period

More information

Surgical technique. DS Evolution System Modular Cup System Double Mobility

Surgical technique. DS Evolution System Modular Cup System Double Mobility Surgical technique DS Evolution System Modular Cup System Double Mobility Table of Contents Introduction 1. Indications and Contraindications 5 2. Preoperative planning 6 3. Surgical Technique 8 3.1 DS

More information

39 year old, 260 lb. park ranger. TKA in situ: 4 Years. First reported Metal-backed, non-modular PCA knee. 16% incidence. Modular metalbacked

39 year old, 260 lb. park ranger. TKA in situ: 4 Years. First reported Metal-backed, non-modular PCA knee. 16% incidence. Modular metalbacked Designer (Royalty income) - DePuy A Johnson & Johnson Company Consultant on Knee Products for Smith & Nephew Orthopaedics General Research Funding Inova Health System and the U.S. Army Medical Research

More information

INDEX. Pag. 12. Pag. 05. Pag. 06. Pag. 13. Pag. 06. Pag. 14. Pag. 15. Pag. 15. Pag. 15. Pag. 15. Pag. 08. Pag. 16. Pag. 09. Pag.

INDEX. Pag. 12. Pag. 05. Pag. 06. Pag. 13. Pag. 06. Pag. 14. Pag. 15. Pag. 15. Pag. 15. Pag. 15. Pag. 08. Pag. 16. Pag. 09. Pag. PROSTHESIS MANUAL INDEX PRESENTATION Pag. 05 CEMENT-SCREWED PROSTHESIS Pag. 12 INTRODUCTION PROSTHESIS MANUAL WARNINGS Pag. 06 Pag. 06 IMPRESSION TAKING: NECESSARY MATERIAL PROSTHESIS: NECESSARY MATERIAL

More information

OPTIMAL revision/reconstruction cementless femoral stem with a modular neck

OPTIMAL revision/reconstruction cementless femoral stem with a modular neck OPTIMAL revision/reconstruction cementless femoral stem with a modular neck : important components of the intra medullary part l Cementless femoral stem partial HAP l Double curve in the sagittal plane

More information

Technique Guide Hip Resurfacing System

Technique Guide Hip Resurfacing System Technique Guide Hip Resurfacing System Approximately 5%-18% of all hip arthroplasties are completed on patients with a primary diagnosis of osteonecrosis. Patients are generally younger adults age 35 years

More information

StelKast Acetabular. Surgical Protocol and Product Specifications. Including ProForm, Provident, Provident Apical Threaded Hole & Systems

StelKast Acetabular. Surgical Protocol and Product Specifications. Including ProForm, Provident, Provident Apical Threaded Hole & Systems StelKast Acetabular Surgical Protocol and Product Specifications Including ProForm, Provident, Provident Apical Threaded Hole & Systems StelKast Acetabular Surgical Protocol Introduction StelKast offers

More information

MICRODENT EXTERNAL CONNECTION PRODUCTS GUIDE EXTERNAL CONNECTION IMPLANTS IMPLANTOLOGY SYSTEMS. Product presentation. Digital information

MICRODENT EXTERNAL CONNECTION PRODUCTS GUIDE EXTERNAL CONNECTION IMPLANTS IMPLANTOLOGY SYSTEMS. Product presentation. Digital information Product presentation Digital information IMPLANTOLOGY SYSTEMS EXTERNAL CONNECTION PRODUCTS GUIDE www.microdentsystem.com Implant catalogues SYSTEM UNIVERSAL Implantes de conexión externa Other catalogues

More information

Type 1. Type 2. Straumann Bone Level. The L-Series abutments are compatible with» L-SERIES «

Type 1. Type 2. Straumann Bone Level. The L-Series abutments are compatible with» L-SERIES « The L-Series abutments are compatible with L-SERIES «Bone Level DETAILED VIEW Exact view of the direction of the angulation (indexing) of all angled abutments. Type 1 angled over flat Type 2 angled over

More information

FIXATION FIRST WEAR REDUCTION OXIDATIVE STABILITY MECHANICAL INTEGRITY PROVEN TECHNOLOGY

FIXATION FIRST WEAR REDUCTION OXIDATIVE STABILITY MECHANICAL INTEGRITY PROVEN TECHNOLOGY FIXATION FIRST WEAR REDUCTION OXIDATIVE STABILITY MECHANICAL INTEGRITY PROVEN TECHNOLOGY Fixation First FIXATION FIRST 1958 Charnley Hip Over 1,000,000 implanted 1 96.2 percent survivorship at 32 years

More information

Motion in Every Step

Motion in Every Step Motion in Every Step Metatarsal Implant Systems Lesser Metatarsal Restoration LESSER METATARSAL SURFACE RESTORATION without compromise Specifically designed for the lesser metatarsals Proven fixation provides

More information