The power of simplicity
|
|
- Abner Powers
- 5 years ago
- Views:
Transcription
1 The power of simplicity
2 The power of simplicity Consider the facts, and take a look at the future: Revision TKA procedures are projected to double between now and Restoration of a normal joint line in a balanced and stable joint is critical to achieving good outcomes in knee revisions. 2 Bone loss necessitates the use of intramedullary fixation in knee revisions resulting in the need to place the femoral and tibial components onto the metaphysis independent of the IM canal. 3 Projected TKA Revision Procedures Revision TKA Surgeons Restoration of proper joint line position in revision total knee arthroplasty is essential in promoting 2 recovery of function. Approximately 60% of patients with failed or poorly functioning implants are metal hypersensitive compared to only 10% of the general population. 4 This data suggests that the changing nature of the revision knee arthroplasty will require a higher level of functional outcomes for patients. The growing number of orthopaedic surgeons who will perform these procedures will require a system versatile enough to handle any contingency while being efficient and reproducible.
3 Versatility Fit the implant to the patient...every time! The LEGION Revision Knee System allows you to: obtain optimal stem fixation while balancing the flexion and extension gaps fit the implant to the patient, not the patient to the implant independently position the femoral and tibial components from the stem Flexion and extension balancing Traditional femoral placement LEGION system femoral placement Canal fixation and bone loss may dictate poor placement of components resulting in the inability to balance revision knees with the ideal sized femoral/tibial components. This results in sub-optimal patella function and joint instability. Stability resulting from reestablishment of the joint line in relationship to the patella, combined with a well-balanced knee in both flexion and extension, can be accomplished with a broad assortment of femoral and tibial screw-on augments and the LEGION system s versatile offset couplers. Traditional Stem Placement LEGION System Stem Placement Cemented Cementless Stem fixation may be lost due to non-centered stem placement resulting in poor cement mantles or partial engagement of pressfit stems. Cemented Cementless Stem location is not compromised in order to achieve optimal femoral/tibial placement. The LEGION system s versatile offset couplers allow optimal placement of both femoral and tibial components while centering stems within the IM canal.
4 Endurance Reduced wear and particle generation Aseptic loosening represents the most common cause of late failure of prosthetic implants. 5 Particulate debris including bone and bone cement causes third-body wear of implants. These particles, combined with wear debris, are accepted as key mechanisms responsible for accelerated wear and osteolysis leading to early failure. OXINIUM Oxidized Zirconium Femorals Abrasion-resistant advanced bearing material: Reduces wear by up to 96% in knees compared to CoCr in lab testing 6,7 8, 9, 10 Clinically proven material: up to 10 year follow-up data Award-winning material: Only ASM award winning material in orthopaedics 11 VERILAST Technology OXINIUM oxidized material combined with highly cross-linked polyethylene is the only TKA-bearing coupling designed to provide outstanding wear performance, even under abrasive conditions. Wear Rate (mm 3 /MC) Pristine Roughened Pristine Roughened Pristine Roughened Pristine Roughened Pristine Roughened 5 MRad 6.5 MRad 7.5 MRad 9 MRad VERILAST Technology A solution for metal hypersensitivity OXINIUM Oxidized Zirconium has undetectable nickel content and has been shown clinically as a viable option for patients with diagnosed metal hypersensitivity 12 Maximum nickel content Not detectable Oxidized Zirconium (<.0035) 0.1% PS High Flexion to Constrained Allows surgeon to decide appropriate level of constraint Choose from PS High Flexion to Constrained Level of constraint is independent of femoral or stem selection needs Titanium 0.5% Cobalt Chrome 0.0% 0.2% 0.4% 0.6% 0.8% 1.0% Maximum percentage of nickel Same A-P resection add constraint and stems PS High Flexion* PS Constrained
5 Ease Designed by surgeons for surgeons Designed to meet the needs of surgeons performing from one to one hundred knee revisions a year, the LEGION system instrumentation reduces surgical time and simplifies intraoperative decision-making. 5 Refer to LEGION Revision Knee System surgical technique for additional information. The technique is essentially the same for both the femur and the tibia, shortening the learning the curve and the procedure. The power of simplicity. 1. The block attaches rigidly to reamer for stability 2. Offset from canal is simply measured using the collets 3. Once the trial goes on, it never has to come off Tibial overview Ream and resect Size, assess offset and counterbore Trial Cut for wedges and punch for fins Femoral overview Ream and resect Size, assess offset and counterbore Prepare for PS Box Trial
6 Special thanks to Dr. Hilde Vandenneucker, UZ Leuven, Belgium References 1 Rapp S. Help wanted in 2030: TJR will soar, severe surgeon shortage possible. Orthopedics Today, May Mahoney OM, Kinsey TL. Modular Femoral Offset Stems Facilitate Joint Line Restoration in Revision Knee Arthroplasty. Clin Orthop Relat Res May; 446: Abraham R, Malkani AL, Lewis J, Beck D. An anatomical study of tibial metaphyseal/diaphyseal mismatch during revision total knee arthroplasty. Journal of Arthroplasty Feb;22(2): Hallab N, Merritt K, Jacobs, JJ. Metal Sensitivity in Patients with Orthopaedic Implants. J Bone Joint Surg Am. 2001;83: Nadaud M, Synder MA, Brown D, McPherron A. New trends and early clinical outcomes with a modern knee revision system. Orthopedics Vol. 30 No. 8., pp Ries MD, Salehi A, Widding K, Hunter G. Polyethylene wear performance of oxidized zirconium and cobaltchromium knee components under abrasive conditions. J Bone Joint Surg Am. 2002;84-A Suppl 2: Spector BM, Ries MD, Bourne RB, Sauer WS, Long M, Hunter G. Wear performance of ultra-high molecular weight polyethylene on oxidized zirconium total knee femoral components. J Bone Joint Surg Am. 2001;83- A Suppl 2 Pt 2: Masonis JL, Kuremsky MA, Thompson C, Odum SM, Mokris JG, Springer BD. Mid-Term Outcomes of Oxidized Zirconium Femoral Components for Total Knee Arthroplasty. Poster. AAOS 2008 San Francisco, CA. 9 Sah AP, Ready JE. Use of oxidized zirconium hemiarthroplasty in hip fractures: clinical results and spectrum analysis. J Arthroplasty Dec;22(8): Laskin RS. An oxidized Zr ceramic surfaced femoral component for total knee arthroplasty. Clin Orthop Relat Res Nov;(416): recipient of ASM International s annual Engineering Materials Achievement Award for, the development of Oxinium Oxidized Zirconium for use as a joint replacement material to improve the performance and increase the service life of total joint replacement systems. 12 Nasser S. Orthopedics. Orthopedic metal immune hypersensitivity Aug;30(8 Suppl): Orthopaedic Reconstruction & Trauma Smith & Nephew, Inc Brooks Road Memphis, TN USA Telephone: Information: Orders and Inquiries: Trademark of Smith & Nephew. Reg. US Pat. & TM Off. All Trademarks acknowledged Smith & Nephew, Inc. All rights reserved /08
LEGION Total Knee System. Exceptional Durability
LEGION Total Knee System Exceptional Durability How many knee systems have been lab-tested to 30 years of simulated wear? Just one: LEGION Primary Knee System with VERILAST Technology The LEGION Primary
More informationThe challenge. Knee replacement patients report lower levels of satisfaction versus hip replacement patients. Return to sports activity post surgery
The challenge Knee replacement patients report lower levels of satisfaction versus hip replacement patients. Return to sports activity post surgery THA 52% Post-op TKA 42% Preop 36% Preop 34% Post-op Total
More informationComprehensive Solutions
Comprehensive Solutions Supporting healthcare professionals Flexibility Today s knee implant patients present increasingly diverse scenarios. The versatility of the JOURNEY II Total allows surgeons to
More informationIntramedullary Tibial Preparation
Surgical Technique Intramedullary Tibial Preparation Primary Total Knee Arthroplasty LEGION Total Knee System Intramedullary tibial preparation Contents Introduction...2 IM tibial highlights...3 Preoperative
More informationWhy precision is powerful
Why precision is powerful A new answer for isolated patellofemoral OA First generation PFJ implants had sharp, constraining trochlear grooves and were prone to complications such as maltracking and catching
More informationDistal Cut First Femoral Preparation
Surgical Technique Distal Cut First Femoral Preparation Primary Total Knee Arthroplasty LEGION Total Knee System Femoral preparation Contents Introduction...3 DCF femoral highlights...4 Preoperative planning...6
More informationI want that next-generation knee
I want that next-generation knee High flex Potentially longer-lasting More normal feeling Gender-optimized Less-invasive procedure Advanced design technology The last ten years have yielded an explosion
More informationDesigned for life. Implant technology with unmatched wear performance
Designed for life Implant technology with unmatched wear performance Designed for life Wear performance combined with a multitude of options so you can find the right combination to restore the joints
More informationSurgical Technique. VISIONAIRE Disposable Instruments for the LEGION Total Knee System
Surgical Technique VISIONAIRE Disposable Instruments for the LEGION Total Knee System VISIONAIRE and LEGION Disposable instrument technique* Note: All disposable instruments are interchangeable with the
More informationExtramedullary Tibial Preparation
Surgical Technique Extramedullary Tibial Preparation Primary Total Knee Arthroplasty LEGION Total Knee System Extramedullary tibial preparation Contents Introduction...2 EM tibial highlights...3 Preoperative
More informationReaching new heights. Comprehensive. Efficient. Simple.
Reaching new heights Comprehensive. Efficient. Simple. Various acetabular cup choices Compatible with the different head and liner options including VERILAST Technology Reach for proven OR efficient Instrumentation
More informationOne system for all revision types
Design Rationale 1 Introduction Revisions today are anything but routine. As more patients have their first total hip at a younger age, it s becoming common for many to have multiple revision surgeries
More informationResurfacing Patellar Preparation
Surgical Technique Resurfacing Patellar Preparation Primary Total Knee Arthroplasty LEGION Total Knee System Resurfacing Patellar preparation Contents Introduction...2 Instrument assembly...3 Resurfacing
More informationAseptic Revision Total Knee Surgical Techniques. Andrew Ehmke, DO Chicago, IL May 5, 2018
Aseptic Revision Total Knee Surgical Techniques Andrew Ehmke, DO Chicago, IL May 5, 2018 I have no disclosures relevant to this talk 3 Phases of Revision 1. Exposure Key to the case!! 2. Component Removal
More informationGENESIS II/ LEGION Total Knee System
GENESIS II/ LEGION Total Knee System The GENESIS II/LEGION knee with the VERILAST technology The knee tested to simulate 30 years of wear performance DISCLAIMER: Always speak to your doctor about the options
More informationBone Bangalore
Dr Suresh Annamalai MBBS, MRCS(Edn), FRCS( Tr & Orth)(Edn), FEBOT(European Board), Young Hip and Knee Fellowship(Harrogate, UK) Consultant Arthroplasty and Arthroscopic Surgeon Manipal Hospital, Whitefield,
More informationR3think your options. For US distribution only.
R3think your options For US distribution only. R3think acetabular surgery It is widely accepted that total hip replacement surgery is one of the most successful procedures done today. Typically more thought
More informationSurgical Technique. VISIONAIRE FastPak Instruments for the LEGION Total Knee System
Surgical Technique VISIONAIRE FastPak Instruments for the LEGION Total Knee System VISIONAIRE FastPak for LEGION Instrument Technique* Nota Bene The technique description herein is made available to the
More informationTHE ATTUNE REVISION FIXED BEARING KNEE SYSTEM
THE ATTUNE REVISION FIXED BEARING KNEE SYSTEM Instrumentation Designed to Enhance Efficiency and Versatility Surgical Process and Key Instrument Overview Introduction TABLE OF CONTENTS ADDRESS VARYING
More informationINTERTAN Nails Geared for Stability
Geared for stability The TRIGEN INTERTAN nail brings advanced TRIGEN nail technology to hip fractures. With a unique integrated, interlocking screw construct, TRIGEN INTERTAN nail provides all the benefits
More informationTHE ATTUNE REVISION ROTATING PLATFORM KNEE SYSTEM
THE ATTUNE REVISION ROTATING PLATFORM KNEE SYSTEM Instrumentation Designed to Enhance Efficiency and Versatility Surgical Process and Key Instrument Overview Introduction TABLE OF CONTENTS ADDRESS VARYING
More informationU2 PSA. Revision Knee. Surgical Protocol
U2 PSA TM Revision Knee Surgical Protocol Table of Contents 1 Component Removal... 1 2 Tibial Preparation... 1 2.1 Tibial Canal Preparation... 1 2.2 Proximal Tibial Resection... 2 2.3 Non Offset Tibial
More informationOptimum implant geometry
Design Rationale Optimum implant geometry Extending proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available
More informationOptimum implant geometry
Design Rationale Optimum implant geometry Extending the proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available
More informationSurgical Technique. Hinge Disassembly and Rebuild Technique
Surgical Technique Hinge Disassembly and Rebuild Technique Revision Knee Arthroplasty Surgical Technique LEGION HK Hinge Knee System Introduction The LEGION HK Hinge Knee System has been designed as an
More information28 Surgical Technique
Surgical Technique 10 12 14 16 18 20 22 24 28 26 Technique described by James L. Guyton, MD Campbell Clinic Memphis, Tennessee James W. Harkess, MD Campbell Clinic Memphis, Tennessee David G. LaVelle,
More informationTHE PERSONALIZED KNEE
THE PERSONALIZED KNEE REDEFINING PERSONALIZATION Total knee replacement has long ranked among the most successful procedures in modern medicine. While you can expect excellent implant survivorship with
More informationLEGION. Total Knee System. Clinical Heritage
LEGION Total Knee System Clinical Heritage Proven performance, continuous innovation Smith & Nephew has a rich history in the medical field dating back over 150 years. The company has produced many products
More informationREFLECTION Constrained Liner Introduction
Surgical Technique REFLECTION Constrained Liner Introduction Surgical treatment of recurrent dislocation should be directed toward correction of any mechanical abnormalities. If dislocation is caused
More informationLEGION Total Knee System. Clinical Heritage
LEGION Total Knee System Clinical Heritage Proven performance, continuous innovation Smith & Nephew has a rich history in the medical field dating back over 150 years. The company has produced many products
More informationTHE P.F.C. SIGMA FEMORAL ADAPTER. Surgical Technique
THE P.F.C. SIGMA FEMORAL ADAPTER Surgical Technique Contents P.F.C. Sigma Femoral Adapter and Revision Knee Surgery Introduction 2 Preoperative Planning 2 Overview 3 Surgical Technique Preparation of the
More informationDesign Rationale. ECHELON Primary Hip System
Design Rationale ECHELON Primary Hip System ECHELON Primary Total Hip System Addressing clinical issues of cementless hip arthroplasty Cementless total hip arthroplasty has provided a proven method of
More informationAdvanced instrumentation for surgical simplicity
Advanced instrumentation for surgical simplicity *smith&nephew GENESIS II MIS Total Knee Instrumentation All the benefits of MIS TKA, without radically changing your surgical approach The GENESIS II minimally
More informationComprehensive, Efficient and Designed for Revision
Comprehensive, Efficient and Designed for Revision The highly variable and often highly compromised anatomical terrain of each revision procedure requires broad intraoperative options if success is to
More informationProduct Information. *smith&nephew POLARCUP Dual Mobility System
APPLYING SCIENCE TO MOBILITY Combined with VERILAST Technology for unmatched performance Product Information *smith&nephew POLARCUP Dual Mobility System APPLYING SCIENCE TO MOBILITY Combined with VERILAST
More informationUnderstanding Hip Implant Options
Understanding Hip Implant Options Cup (Socket) Bearing (Liner) Head Stem (Femur) Modern Hip Implants (Ball) Metal Femoral Head on Marathon Cross-linked Polyethylene Liner Proven materials Polyethylene
More informationSection of total knee replacement. Total Knee Replacement System. Knieendoprothesen System. Système de prothèse totale de genou
Section of total knee replacement Total Knee Replacement System Knieendoprothesen System Système de prothèse totale de genou Introduction: This knee system features great versality with its modular component
More informationKnee Revision. Portfolio
Knee Revision Portfolio I use the DePuy Revision Knee System because of its versatility. With this system I can solve nearly any situation I encounter in the OR. Dr. Thomas Fehring, OrthoCarolina Hip and
More informationADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY
E C H E L O N P R I M A R Y H I P S Y S T E M P R O D U C T R A T I O N A L E ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY Echelon Primary Total Hip System HIGH OFFSET STANDARD OFFSET Cementless
More informationKnee spanning solutions
Knee spanning solutions System features Indications Intended to be used on adults or pediatric patients as required for fracture fixation (open or closed); post-traumatic joint contracture which has resulted
More informationImportant notice: the device(s) can be prescribed and implanted only by a doctor legally authorized to perform this type of surgery.
rev.10 CAUTION Federal law (USA) restricts this device to sale, by or on the order of a physician. ENGLISH - EVOLIS/GMK KNEE PROSTHESIS - INSTRUCTIONS FOR USE Important notice: the device(s) can be prescribed
More informationRevision of a tibial baseplate using a customized oxinium component in a case of suspected metal allergy A case report
Acta Orthop. Belg., 2011, 77, 691-695 CASE REPORT Revision of a tibial baseplate using a customized oxinium component in a case of suspected metal allergy A case report Nick VAN OPStAl, Frank VERhEyDEN
More informationTrusted technology. Trusted performance. Supporting healthcare professionals
Trusted technology. Trusted performance. Supporting healthcare professionals Trusted technology. Trusted performance. The POLAR3 Total Hip Solution, powered by Smith & Nephew s proprietary VERILAST Technology,
More informationInstrumentation Options
Instrumentation Options With the introduction of Microplasty and Premier Instrumentation platforms and advancements such as our patented Slidex Technology, the Vanguard Complete Knee System is the surgeon
More informationAnalysis of an Early Intervention Tibial Component for Medial Osteoarthritis
Analysis of an Early Intervention Tibial Component for Medial Osteoarthritis Miriam Chaudhary, M.Sc. 1, Peter S. Walker, PhD 2. 1 NYU Hospital for Joint Diseases, New York City, NY, USA, 2 NYU-Hospital
More informationSpecifications guide ECHELON. Hip System
Specifications guide ECHELON Hip System Primary and revision porous implants Porous coating ROUGHCOAT porous coating increases the friction between the implant and bone, improving implant stability and
More informationScorpio TS Single Axis Revision Knee System. Scorpio Total Stabilizer Revision Knee System Surgical Protocol
Scorpio TS Single Axis Revision Knee System Scorpio Total Stabilizer Revision Knee System Surgical Protocol Table of Contents Scorpio Total Stabilizer Revision Knee System Surgical Protocol Component
More informationCommon Instruments for Biomet Hip Systems
E F F I C I E N T E F F E C T I V E E Common Instruments for Biomet Hip Systems X A C T I N S T R U M E N TAT I O N Exact Hip Instrumentation was developed by Biomet engineers to address the needs of today
More informationCementing better outcomes
Cementing better outcomes The challenge Orthopaedic surgeons are demanding a simpler and superior bone cement solution for implant placement procedures. Surgeons need a bone cement portfolio with the necessary
More informationBone Preservation Stem
TRI-LOCK Bone Preservation Stem Featuring GRIPTION Coating Surgical Technique Implant Geometry Extending the TRI-LOCK Stem heritage The original TRI-LOCK Stem was introduced in 1981. This implant was
More informationTrabecular Metal Tibial Cone Surgical Technique
Trabecular Metal Tibial Cone Surgical Technique Provides structural support in areas of bone loss Trabecular Metal Cone 1 Zimmer Trabecular Metal Tibial Cone Surgical Technique Table of Contents Overview
More informationThe Leader in Orthopaedic Innovation
The Leader in Orthopaedic Innovation Wright is a leading international manufacturer and distributor of superior, easy to use, and innovative orthopaedic implants and instrumentation. For over 50 years,
More informationDesign Rationale and Surgical Technique. *smith&nephew TANDEM. Bipolar and Unipolar Hip System
Design Rationale and Surgical Technique *smith&nephew TANDEM Bipolar and Unipolar Hip System Maximizing performance from every angle Saving time in the operating room is one of the most valuable solutions
More informationOptimum implant geometry
Surgical Technique Optimum implant geometry Extending proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available
More informationESC. Enhanced Stability Liners. Design Rationale & Surgical Technique
ESC Enhanced Stability Liners Design Rationale & Surgical Technique Choice Without Compromise DePuy Synthes PINNACLE Hip Solutions are designed with a wide range of acetabular cup options, biological and
More informationCPCS. Training Manual. Collarless Polished Cemented Stem
SMITH & NEPHEW ORTHOPAEDICS ~ TRUST. INNOVATION. PERFORMANCE. CPCS Collarless Polished Cemented Stem Training Manual This document is for internal use by Smith & Nephew and sales force only and is not
More informationWhat Are Hip and Knee Replacement Implants Made Of?
What Are Hip and Knee Replacement Implants Made Of? Hip and knee replacement surgery involve replacing the worn-out bone and cartilage lining your hip or knee joint with new implants that are composed
More informationJOINT RULER. Surgical Technique For Knee Joint JRReplacement
JR JOINT RULER Surgical Technique For Knee Joint JRReplacement INTRODUCTION The Joint Ruler * is designed to help reduce the incidence of flexion, extension, and patellofemoral joint problems by allowing
More informationFeaturing. Technology. Product Rationale
Featuring Technology Product Rationale 2 Optimum implant geometry Extending proven TRI-LOCK heritage The original TRI-LOCK Stem was introduced in 1981. This implant was the first proximally coated tapered-wedge
More informationEncina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA
Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA 94065 info@stinsonortho.com www.stinsonortho.com Table of Contents Introduction 3 Features 4 Surgical Technique 5 Preoperative
More informationClinical Evaluation Surgical Technique
Clinical Evaluation Surgical Technique Table of Contents EMPERION Specifications 3 EMPERION Surgical Technique 9 EMPERION Catalog 18 Nota Bene: This technique description herein is made available to the
More informationNewer designs in Knee replacement The good,bad & ugly! Dr VAIBHAV BAGARIA
Newer designs in Knee replacement The good,bad & ugly! Dr VAIBHAV BAGARIA MBBS, MS, FCPS, DIP SICOT. Arthroplasty fellow- USA, Germany, Aus Joint replacement surgeon COLUMBIA ASIA HOSPITAL, GZB. Fresh
More informationEnhanced Stability Constrained Liners. Design Rationale Surgical Technique
Enhanced Stability Constrained Liners Design Rationale Surgical Technique The Pinnacle Acetabular Cup System was designed to maximize the number of options available to the surgeon, and provide those options
More informationREVISION KNEE REPLACEMENT
REVISION KNEE REPLACEMENT Dr Keith Holt Revision Total Knee Replacement is, unfortunately, now becoming more common. Knee replacement has been performed in some numbers for over 30 years, and hence, many
More informationTOTAL HIP REPLACEMENT:
THR Prosthesis Design TOTAL HIP REPLACEMENT: PROSTHESIS DESIGN FEATURES JESS JOHNSTON & MELINDA ZIETH History of Hip Prosthesis Joint Replacement Registry Implant Design Technology & Future History and
More informationTHE KNEE SOCIETY VIRTUAL FELLOWSHIP
THE KNEE SOCIETY VIRTUAL FELLOWSHIP CHAPTER 16 LONG-TERM FAILURE MECHANISMS AND SURVIVORSHIP Long-Term Failure Mechanisms and Survivorship Presented by: Michael A. Mont, MD, Assem A. Sultan, MD, and Michael
More informationG7 ACETABULAR SYSTEM. beautifully. efficient.
G7 ACETABULAR SYSTEM beautifully efficient. HERITAGE MEETS MODERN DESIGN SIMPLICITY, EFFICIENCY AND PERFORMANCE The G7 System is a multi-bearing acetabular platform delivering simplicity, efficiency and
More informationOver 20 Years of Proven Clinical Success. Zimmer Natural-Knee II System
Over 20 Years of Proven Clinical Success Zimmer Natural-Knee II System CSTi Porous Coating Structurally similar to human bone CSTi porous coating combines the excellent biocompatibility of titanium with
More informationLPS SYSTEM POCKET GUIDE
LPS SYSTEM POCKET GUIDE Implants Procedural Uses Instruments & Trials L P S Limb Preservation System L P S Limb Preservation System The purpose of this document is to review the LPS (Limb Preservation
More informationCase report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis?
Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis? Diagnosis: Ceramic head fracture In the 1970 s, Boutin implemented ceramic in modern total hip arthroplasty (THA).
More informationThe TRIGEN SURESHOT system has my back.
Because control means everything to me. The TRIGEN SURESHOT system has my back. Introducing the TRIGEN SURESHOT Distal Targeting System, the revolutionary virtual imaging system that does so much more.
More informationKnee Replacement Implants
Knee Replacement Implants During knee replacement surgery, an orthopaedic surgeon will resurface your damaged knee with artificial components, called implants. There are many different types of implants.
More informationDual Articular.
Dual Articular 2000 www.biomet.co.uk D e s i g n R a t i o n a l e The Dual Articular Knee has been in use since 1991 and offers a flexible reconstructive solution for total knee surgery; for both revision
More informationAnterior Cut First Surgical Technique
Anterior Cut First Surgical Technique GENESIS II Anterior Cut First Surgical Technique Table of Contents Introduction....................................... 2 Preop Planning....................................
More informationExplore the possibilities
Explore the possibilities Q Do you have a single solution for treating complex fractures and deformities? 12 year-old with Blount s Disease 29 year-old with pilon fracture 36 year-old with mal-union A
More informationEXACTECH KNEE. Operative Technique ADDENDUM. Metaphyseal Cones. Surgeon focused. Patient driven. TM
EXACTECH KNEE Operative Technique ADDENDUM Metaphyseal Cones Surgeon focused. Patient driven. TM TABLE OF CONTENTS INTRODUCTION...1 DESCRIPTION...1 DETAILED OPERATIVE TECHNIQUE Initial Preparation and
More information*smith&nephew CONTOUR
Surgical Technique *smith&nephew CONTOUR Acetabular Rings CONTOUR Acetabular Rings Surgical technique completed in conjunction with Joseph Schatzker MD, BSc (Med.), FRCS (C) Allan E. Gross, MD, FRCS (C)
More informationTibial Base Design Factors Affecting Tibial Coverage After Total Knee Arthroplasty: Symmetric Versus Asymmetric Bases
Tibial Base Design Factors Affecting Tibial Coverage After Total Knee Arthroplasty: Symmetric Versus Asymmetric Bases Chadd Clary, PhD I Staff Engineer I DePuy Synthes Joint Reconstruction Daren Deffenbaugh,
More informationPROPHECY INBONE. Preoperative Navigation Guides
PROPHECY INBONE Preoperative Navigation Guides Simple. Fast. Accurate. Simple. Fast. Accurate. Prophecy Envision the Results PROPHECY Preoperative Navigation Guides have ushered in a new era of total ankle
More informationA better knee replacement begins with you
A better knee replacement begins with you Why your scans are so important VISIONAIRE Patient Matched Instrumentation is a patient specific product that requires MRI and an X-Ray to make the product. The
More informationCMA TM Cemented Modular Augmentable. Baseplate. 2 Knee
CMA TM Cemented Modular Augmentable Baseplate 2 Knee More can be addressed The U2 Cemented Modular Augmentable Baseplate is an optimal solution for tibial bone defect in primary total knee replacement.
More informationTotal Knee Original System Primary Surgical Technique
Surgical Procedure Total Knee Original System Primary Surgical Technique Where as a total hip replacement is primarily a bony operation, a total knee replacement is primarily a soft tissue operation. Excellent
More informationStefan Rahm MD University Hospital Balgrist
Knee Prosthesis Models & Materials, Surgical Techniques and Approaches Stefan Rahm MD University Hospital Balgrist INTRODUCTION VARUS VALGUS 46 Y OLD MALE Pain in the medial compartment left more than
More informationSTABILITY & MOTION VS. THE PERSONA KNEE SYSTEM. The Zimmer Persona Knee
STABILITY & MOTION VS. THE PERSONA KNEE SYSTEM The Zimmer Persona Knee The ATTUNE Knee System was designed to deliver stability and motion while the Zimmer Persona Knee System emphasizes the number of
More informationWe would like to thank the following surgeons for their participation as part of the R3 Acetabular System design team:
Design Rationale We would like to thank the following surgeons for their participation as part of the R3 Acetabular System design team: Robert Barrack, MD St. Louis, Missouri Robert Bourne, MD London Health
More informationATTUNE Knee System: Stability in Total Knee Replacement
ATTUNE Knee System: Stability in Total Knee Replacement Chadd Clary, PhD Staff Engineer DePuy Synthes Joint Reconstruction Young and active total knee replacement (TKR) patients demand a knee that feels
More informationSulzer Orthopedics Joint & Fracture Care
Sulzer Orthopedics Joint & Fracture Care Natural-Knee Family Anatomic design for superior clinical results. Natural-Knee Natural-Knee Family: A solution for every knee. Asymmetric design increases coverage
More informationConsistency in U2 Knee System over Time
U2 TM Knee System Consistency in U2 Knee System over Time Share the same femoral profile of all types allow inter-changibility Uniform AP/ML dimensions in all tibial components enhance intraoperative flexibility
More informationCAUTION: Ceramic liners are not approved for use in the United States.
Total Hip Prostheses, Self-Centering Hip Prostheses and Hemi-Hip Prostheses IMPORTANT: This essential product information sheet does not include all of the information necessary for selection and use of
More informationSURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS
SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS INTRODUCTION The Summit Tapered Hip System s comprehensive set of implants and instruments
More informationS h o u l d e r Solutions by Tornier C o n v e r T i b l e S h o u l d e r S y S T e m
S h o u l d e r Solutions by Tornier C o n v e r t i b l e s h o u l d e r s y s t e m C o n v e r t i b l e s h o u l d e r s y s t e m A n a t o m i c Aequalis Ascend Flex - UDZF131 One System. Two Solutions.
More informationCURRICULUM VITAE CHRISTINE STEUBBEN HEIM Ward Drive Chesterland, OH Telephone:
EDUCATION CURRICULUM VITAE CHRISTINE STEUBBEN HEIM 12655 Ward Drive Chesterland, OH 44026 Telephone: +440 729 9274 B.Sc. (Biomedical Engineering) Case Western Reserve University, Cleveland, Ohio (1992)
More informationSingle Axis Revision Knee System
Orthopaedics Scorpio TS Single Axis Revision Knee System Scorpio TS Trial Cutting Guide Surgical Protocol Orthopaedics Scorpio TS Single Axis Revision Knee System Scorpio TS Trial Cutting Guide Surgical
More informationEXPERIENCE GPS FOR TOTAL KNEE ARTHROPLASTY DETERMINE YOUR OWN COURSE.
EXPERIENCE GPS FOR TOTAL KNEE ARTHROPLASTY DETERMINE YOUR OWN COURSE. The year 2010 marked Exactech s silver aiversary and 25 years of mobility. As a company founded by an orthopaedic surgeon and a biomedical
More informationU2 PSA. Revision Knee. Surgical Protocol
U2 PSA TM Revision Knee Surgical Protocol Table of Contents 1 Component Removal... 2 Tibial Preparation... 2.1 Tibial Canal Preparation... 2.2 Proximal Tibial Resection... 2.3 Non Offset Tibial Preparation...
More informationRECLAIM REVISION HIP SYSTEM
RECLAIM REVISION HIP SYSTEM Where Strength and Modularity Connect DESIGN RATIONALE System Overview RECLAIM Modular Revision Hip System WHERE STRENGTH & MODULARITY CONNECT 2 Offset Options Proximal Body
More informationArcos Modular Femoral Revision System
Arcos Modular Femoral Revision System Arcos System Simplify the Complex The Arcos Modular Femoral Revision System meets the demands of complex hip revision surgery by offering surgeons and OR staff the
More informationoperative technique Kent Hip
operative technique Kent Hip The Kent Hip Operative Technique The Kent Hip was developed by Mr Cliff Stossel, FRCS in Maidstone, Kent, UK and first implanted in 1986. It was designed to deal with problems
More informationM-SERIES. Modular Femoral Stem AN ACCURATE MATCH EVERY TIME
M-SERIES Modular Femoral Stem AN ACCURATE MATCH EVERY TIME 54 Extension 114 Flexion High How do you ensure optimal post-operative joint stability? MECHANICAL RANGE OF MOTION Cup Position: 45 degrees abduction,
More information