Distal radius fractures raises considerable interest and

Size: px
Start display at page:

Download "Distal radius fractures raises considerable interest and"

Transcription

1 Original Article Two peg spade plate for distal radius fractures A novel technique Sharad M Hardikar, Sreenivas Prakash, Madan S Hardikar, Rohit Kumar Abstract Background: The management of distal radius fractures raises considerable debate among orthopedic surgeons. The amount of axial shortening of the radius correlates with the functional disability after the fracture. Furthermore, articular incongruity has been correlated with the development of arthritis at the radiocarpal joint. We used two peg volar spade plate to provide a fixed angle subchondral support in comminuted distal radius fractures with early mobilization of the joint. Materials and Methods: Forty patients (26 males and 14 females) from a period between January 2009 and December 2011 were treated with two peg volar spade plate fixation for distal radius fracture after obtaining reduction using a mini external fixator. Patients were evaluated using the demerit point system of Gartland and Werley and Sarmiento modification of Lindstrom criteria at final followup of 24 months. Results: The average age was years (range years). Excellent to good results were seen in 85% (n = 34) and in all patients when rated according to the demerit point system of Gartland and Werley and Sarmiento modification of Lindstrom criteria, respectively. Complications observed were wrist stiffness in 5% (n = 2) and reflex sympathetic dystrophy in 2.5% (n = 1). Conclusions: The two peg volar spade plate provides a stable subchondral support in comminuted intraarticular fractures and maintains reduction in osteoporotic fractures of the distal radius. Early mobilization with this implant helps in restoring wrist motion and to prevent development of wrist stiffness. Key words: Colles fractures, distal radius fractures, external fixators, volar plates MeSH terms: Fracture fixation, bone plates, radius fractures Introduction Distal radius fractures raises considerable interest and debate amongst orthopedic surgeons. It is an injury seen with high frequency, representing approximately one in six cases seen in the emergency department. 1 For years, distal radius fractures were injuries assumed to be colles fracture and warrant no more than a cast. 1 Various treatment modalities have been devised ranging from cast immobilization, percutaneous fixation, external fixation, open reduction and internal fixation to arthroscopic Department of Orthopaedics, Hardikar Hospital, Pune, Maharashtra, India Address for correspondence: Dr. Rohit Kumar, 1160/61, Hardikar Hospital, University Road, Shivaji Nagar, Pune , Maharashtra, India. E mail: rohit @yahoo.co.in Quick Response Code: Access this article online Website: DOI: / internal fixation. The amount of axial shortening of the radius correlates with the functional disability after the fracture. 2 Furthermore, articular incongruity has been correlated with the development of arthritis at the radiocarpal joint. 3 Malunion of the fracture distal radius has been associated with pain, stiffness, weak grip strength and carpal instability. Long term consequences include degenerative arthritis in up to 50% of patient with even minimal displacement of fracture fragments. 4 Conventional T plates and locking plate system rely on distal screws for stability. They can result in loss of reduction that is, axial shortening or dorsal or volar angulations when wrist mobilization is started. This is due to an unstable interface between the plate and screw head referred to as toggling. In order to address this problem of loss of reduction on early mobilization, many new plates have been designed, which provide a fixed angle subchondral support under the scaphoid and lunate fossae which are the areas of maximal axial stress. Hence, we designed a two peg volar spade plate wherein two volar pegs are fused to the plate to provide an angular stable support to the distal articular surface. Also, being broad on their distal aspect, these plates provide more contact Indian Journal of Orthopaedics September 2015 Vol. 49 Issue 5 536

2 support to the comminuted distal radius, corresponding to its anatomical shape. The plate allows two 2.5 mm screws to be inserted on either side of the pegs to provide a total of 10 mm subchondral support. The plates are not side specific, and the same plate can be used on either left or right radii, thus being universal. The plate is comparatively thinner (1.5 mm) than locked plates (3.5 mm) to suit the Indian population. The modification of the design prevented the above complications of locked and other buttress plates. This study evaluated that two peg volar spade plate for the fixation of comminuted osteoporotic and malunited fractures of the distal radius in terms of functional and anatomical outcomes. Materials and Methods Forty five patients were enrolled in the study who fulfilled the inclusion criteria, out of which five patients were lost to followup of 24 months, hence excluded. This retrospective study included 40 patients of distal radius fractures operated with two peg volar spade plate between January 2009 and December Both males and females, aged between 20 and 75 years and fractures with articular/metaphyseal comminution or impaction that is, AO/ASIF classification types A2, A3, C1, C2 and C3, osteoporotic fractures, malunited colles with manus valgus were included. Type B fractures, patient who did not complete the followup criteria or who did not give consent, were excluded. Patients were regularly followed up at 2, 4, 6 and 8 weeks and thereafter 6, 12 and 24 months. Anteroposterior and lateral X rays were taken to determine union and if any residual deformity was present. Patients were evaluated using the demerit point system of Gartland and Werley 5 and Sarmiento modification of Lindstrom criteria. 6 The range of motion used for comparison are standardized. 7 An informed consent was taken from all the patients and approval of Ethics and Scientific Committee of Department of Orthopedics. medial fragments. Hence, a total of 10 mm of subchondral support is achieved with the help of two pegs and two screws [Figure 1]. Operative procedure The patients were operated under supraclavicular brachial plexus block, intra venous regional anesthesia or general anesthesia. First an external fixator was used to mark its placement with skin impression and then applied with one 2.5 mm Schanz pin in the radius about 10 cm proximal to the fracture and another Schanz pin in the base of the second metacarpal laterally with forearm in supination. The external fixator was distracted to achieve radial length and attain preliminary reduction/distraction of the fracture. A volar approach was used with an incision over the tendon of flexor carpi radialis. The fracture site was opened through tendon sheath. The pronator quadratus, was erased from the radius beginning laterally and retracted ulnar wards. Fracture reduction was achieved. Distraction/ compression was adjusted according to the requirement. Metaphyseal comminution in some cases necessitated bone grafting. Cancellous bone graft was harvested from the upper end of the tibia. The jig was placed over the distal radius and two drill holes with 2.7 mm drill bit were Implant description The implant used was the volar spade plate with two volar pegs [A.K Surgicals, Pune, India]. The plate is 1.5 mm thick made of stainless steel 316 L. Length of the plate is 50 mm and it is 28 mm broad distally. There are two square pegs fused to the plate distally in an inert atmosphere of argon. Each peg is 2.5 mm broad, 2.5 mm thick and 16 mm in length. These pegs provide support under the scaphoid and lunate fossae. The pegs do not penetrate the opposite cortex to prevent extensor tendon irritation or rupture. Additional holes are present at either corner of the plate in line with the pegs, 2.5 mm screws can be placed through these holes to hold the lateral and Figure 1: Photograph of two peg volar spade plate with its measurements 537 Indian Journal of Orthopaedics September 2015 Vol. 49 Issue 5

3 made only in the volar cortex to receive the two pegs. These holes should be as distally as possible to provide optimal subchondral support. Jig was then removed, and plate was hammered in and checked under image. Out of the two distal screws, one was directed in the radial styloid and another in the postero medial cortex of the radius. The other proximal screws were placed simultaneously. On confirming adequate stability after fixation of the plate, the fixator was removed. Postoperative protocol 0 2 weeks Movements of the fingers, elbow and shoulder were encouraged in the first 2 weeks. Elevation of the forearm was maintained during the first 2 days to avoid edema. 2 4 weeks In extraarticular fractures, wrist (dorsiflexion and palmarflexion), finger (flexion and extension) and forearm (pronation and supination) mobilization were started. In type C fractures (intraarticular), where the comminution was significant, a below elbow splint was used for 2 3 weeks. Results The average age was years (range years). Twenty six were males and 14 females. They were all closed fracture and were classified according to AO/ASIF system, including type A2 (n = 4), type A3 (n = 10), type C1 (n = 8), type C2 (n = 8) and type C3 (n = 10) [Figure 2A]. Right side was fractures in 18 cases and left side in 22 cases. Postoperative average movements [Table 1] [Figure 2B] and radiological outcome in terms of loss of palmar tilt, radial shortening and loss of radial deviation was measured according to Sarmiento modification of Lindstrom criteria at final followup [Tables 2 and 3]. According to the Gartland and Werley demerit point system excellent results were seen in 25% (n = 10), good results in 60% (n = 24), fair in 15% (n = 6) and poor in none (n = 0). We also found out that type A fractures showed excellent to good results and 15% of fair results were seen in type C fractures [Tables 4 and 5]. Two patients presented with wrist stiffness (5%) with a fair outcome and one with reflex sympathetic dystrophy (2.5%). After 4 weeks Range of motion exercises was continued with gradually progressive use of the wrist being permitted. Followup record was maintained at 2, 4, 6 and 8 weeks and thereafter 6, 12 and 24 months. Discussion In our study, 50% of the cases were of OTA type C that is, complete articular fractures. According to Knirk and Jupiter, 3 these fractures must always be separated from extra articular Statistical analysis The descriptive analysis consisted of frequency and percentage for discrete data and meant for continuous data. In cases where pre and postoperative assessment was not available P value was not calculated but descriptive statistics has been provided for comparison with other studies in the literature. a b Figure 2A: (a) X-ray distal forearm with wrist joint anteroposterior and lateral views showing AO type C3 fracture distal end radius (b) Postoperative x-rays anteroposterior and lateral views showing peg spade plate in situ Figure 2B: Clinical photograph of same patient with complete range of motion of wrist at final followup Indian Journal of Orthopaedics September 2015 Vol. 49 Issue 5 538

4 Table 1: Mean average range of motion at last followup Values Dorsiflexion Palmarflexion Radial deviation Ulnar deviation Pronation Supination Average Normal fractures as their response to treatment and the functional outcomes are always quite distinct. Thielke et al. [8] used fixed angle plates and von Recum et al. [9] used 2.4 and 3.5 mm LCP for fixation of these fractures. Extra articular comminuted fractures (type A2 and A3) are inherently prone to re displacement after closed reduction. Hence, they have been included in the study. Other indications were osteoporosis, comminution where maintenance of radial length was required, fractures with late presentation as well as malunited extra articular fractures. The volar approach has been used for fixation of the distal radius fracture in our series. In a series of study by Herron et al. found that dorsal plate placement can lead to extensor tendon irritation, tenosynovitis or tendon rupture and limitation of wrist movements. 10 Hence plate removals are required more often. 10 Advantage of dorsal plate position is that it gives access to the place of the main lesion since the displacement is usually dorsal. However, volar plate position has the advantages of better soft tissue cover, flat surface for easy plate fixation, better tension band effect, leaving dorsal soft tissue intact and avoiding bone graft leakage. 11 Furthermore, removal of the volar plate is not absolutely essential. 12 This has been documented and supported by the studies done by Drobetz and Kutscha Lissberg. 13 Ligamentotaxis with an external fixator has been used. However, the fixator has to be retained for 6 8 weeks. Hence, there is a risk of developing wrist and finger stiffness. Also, ligamentotaxis is not a reliable method to restore radio palmar tilt. We used external fixator in all the patients for ligamentotaxis and fracture reduction, which was removed immediately after plate fixation for early mobilization. This helps in restoring the radial length whereas the tilt is controlled by the internal fixation. Hence, external fixation is combined with internal fixation. 14 In order to provide angular stability and to avoid loss of reduction or collapse Drobetz and Kutscha Lissberg introduced the locked screw plates into use. 13 These plates have matching threads on the screw head and the hole to provide angular stability. However, the plates developed had three 3.5 mm locking screws in the distal row for fixation. These screws and plates are very bulky for the structurally smaller bones. At the same time, plates with four or five fixed angle tines have been developed. These plates function like a blade plate, lessening the role of metaphyseal screws and provide Table 2: Sarmiento modification of Lindstrom criteria Grades Loss of palmar tilt ( ) Radial shortening (mm) Loss of radial deviation ( ) Excellent 0 <3 5 Good Fair Poor At least 15 At least 12 >14 Table 3: Result based on Sarmiento modification of Lindstrom criteria Grades Loss of palmar tilt ( ) Radial shortening (mm) Loss of radial deviation ( ) Excellent (%) 2 (5) 35 (87.5) 37 (92.5) Good (%) 38 (95) 5 (12.5) 3 (7.5) Fair Poor Values are the number of patients in each criteria with percentage in brackets Table 4: Demerit point system of Gartland and Werley Residual deformity Range 0-3 points Prominent ulnar styloid 1 Residual dorsal tilt 2 Radial deviation of hand 2-3 Subjective evaluation Range 0-6 points Excellent - No pain, disability or limitation of 0 movements Good - Occasional pain, limitation of motion, 2 no disability Fair- Occasional pain, some limitation of 4 motion, weakness in wrist, no disability if careful, activities slightly restricted Poor - Pain, limitation of motion, disability, 6 activities more or less markedly restricted Objective evaluation Range 0-5 points Loss of dorsiflexion 5 Loss of ulnar deviation 3 Loss of supination 2 Loss of palmar flexion 1 Loss of radial deviation 1 Loss of circumduction 1 Pain in DRUJ 1 Grip strength 60% or less than opposite side 1 DRUJ=Distal radioulnar joint rigid fixation allowing early motion. 15 But putting in four or five tined plate was technically more difficult and hence the plates are out of favour. 16 The two peg volar spade plate which we developed is based on the same principle of angular stability. The two pegs are inserted under the sub chondral bone of the distal radius and support the articular fragments. It is technically easier to place two fixed pegs than to place four tines. Additional 539 Indian Journal of Orthopaedics September 2015 Vol. 49 Issue 5

5 Table 5: Results based on demerit point system of Gartland and Werley Patient number/ Grade Points Type A/C (n) Present series Thielke et al. fixed angle von Recum et al. 2.4 mm/3.5 mm LCP Number of patients Excellent /04 25% 35% 62% 43% Good /16 60% 50% 34% 41% Fair /06 15% 15% 4% 16% Poor >21 0/0 0% 0% LCP=Locked compression plates sub chondral support is achieved by placing two screws, one on either side of the pegs one in the radial styloid and another in the postero medial cortex of radius. Thus, we achieved a total of 10 mm of sub chondral support (using 2.5 mm two screws and two pegs). Moreover, the 2.5 mm construct of the plate is structurally homologous to the Indian radius morphology. Drobetz and Kutscha Lissberg 13 used a forearm splint for 2 weeks postoperatively in type C fractures after fixation with a locked screw plate. In type C fractures with osteoporosis or type C3 fractures with pronounced articular involvement and small fragments, they used the immobilization for 4 weeks. Orbay and Fernandez 15 also used a wrist splint for 3 weeks post operatively after fixation with a volar fixed angled plate. In our study, we used a forearm and wrist brace post operatively for 1 week for extra articular fractures and 2 weeks for intraarticular fractures followed by intermittent usage for the same period later to allow physiotherapy. Thielke et al. 8 used a volar fixed angle plate. Wrist motion was restored to 80% of normal. Orbay and Fernandez 15 on reviewing retrospectively their results of treatment with a volar fixed angle plate reported achieving 58 dorsiflexion, 55 volarflexion, 80 pronation and 76 supination. Our results were comparable. Radiologically Thielke et al. 8 reported a loss of 1 volar tilt, 1 ulnar tilt and radial shortening of 1 mm. Orbay and Fernandez 15 achieved a final volar tilt of 6, ulnar tilt 20 and had a final radial shortening of <1 mm. Our radiological results according to Sarmiento modification of Lindstrom criteria were as mentioned in Table 3. Thielke et al. 8 treated 49 displaced articular fractures with the overall outcome on Gartland and Werley scales being 85% excellent to good scores. Similarly, Recum et al. 9 showed 96% and 86% excellent to good in 2.4 mm and 3.5 mm LCP respectively. We had comparable results of 85% in excellent to good category [Table 5]. We also noticed that patients presented with significant osteoporosis at an early age, which is common in Indian population 17 and also a study by Meiners et al. 18 discussed a newer concept of using an angular stable plates with good results in 90% osteoporotic fractures. 18 The limitations of this study include the absence of a control group and also that it is a retrospective study. To conclude the two peg volar spade plate provides a stable sub chondral support and maintenance of corrective length in osteoporotic, metaphyseal comminuted, comminuted intraarticular and malunited fractures of the distal radius. Early mobilization with this implant helps in restoring wrist motion and prevents development of wrist stiffness. References 1. Colles A. On the fracture of the carpal extremity of the radius. Clin Orthop Relat Res 2006;445: Aro HT, Koivunen T. Minor axial shortening of the radius affects outcome of Colles fracture treatment. J Hand Surg Am 1991;16: Knirk JL, Jupiter JB. Intraarticular fractures of the distal end of the radius in young adults. J Bone Joint Surg Am 1986;68: Taleisnik J, Watson HK. Midcarpal instability caused by malunited fractures of the distal radius. J Hand Surg Am 1984;9: Gartland JJ Jr, Werley CW. Evaluation of healed Colles fractures. J Bone Joint Surg Am 1951;33 A: Sarmiento A, Pratt GW, Berry NC, Sinclair WF. Colles fractures. Functional bracing in supination. J Bone Joint Surg Am 1975;57: Hoppenfeld, S. Physical Examination of the Spine and Extremities. Appleton Century Crofts, a publishing division of Prentice Hall, New York, NY; Thielke KH, Wagner T, Bartsch S, Echtermeyer V. Angularly stable radius plate: Progress in treatment of problematic distal radius fracture? Chirurg 2003;74: Von Recum J, Matschke S, Jupiter JB, Ring D, Souer JS, Huber M, et al. Characteristics of two different locking compression plates in the volar fixation of complex articular distal radius fractures. Bone Joint Res 2012;1: Herron M, Faraj A, Craigen MA. Dorsal plating for displaced intraarticular fractures of the distal radius. Injury 2003;34: Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M. Complications following internal fixation of unstable distal radius fracture with a palmar locking plate. J Orthop Trauma 2007;21: Woon CYL, Lee JYL, Ng SW, Teoh LC. Late rupture of flexor pollicis longus tendon after volar distal radius plating: a case report and review of the literature. Injury (Extra) 2007;38: Drobetz H, Kutscha Lissberg E. Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop 2003;27: Anderson JT, Lucas GL, Buhr BR. Complications of treating Indian Journal of Orthopaedics September 2015 Vol. 49 Issue 5 540

6 distal radius fractures with external fixation: A community experience. Iowa Orthop J 2004;24: Orbay JL, Fernandez DL. Volar fixed angle plate fixation for unstable distal radius fractures in the elderly patient. J Hand Surg Am 2004;29: Sobky K, Baldini T, Thomas K, Bach J, Williams A, Wolf JM. Biomechanical comparison of different volar fracture fixation plates for distal radius fractures. Hand (N Y) 2008;3: Acharya S, Srivastava A, Sen IB. Osteoporosis in Indian women aged years. Arch Osteoporos 2010;5: Meiners J, Jürgens C, Mägerlein S, Wallstabe S, Kienast B, Faschingbauer M. Osteoporotic fractures of the distal radius. What is new?. Chirurg 2012;83: How to cite this article: Hardikar SM, Prakash S, Hardikar MS, Kumar R. Two peg spade plate for distal radius fractures A novel technique. Indian J Orthop 2015;49: Source of Support: Nil, Conflict of Interest: None. 541 Indian Journal of Orthopaedics September 2015 Vol. 49 Issue 5

Technique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

Technique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology. Technique Guide 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology. Table of Contents Introduction 2.4 mm Variable Angle LCP

More information

Surgical Management of Distal end Radius Fractures by Various Methods: A Prospective Study

Surgical Management of Distal end Radius Fractures by Various Methods: A Prospective Study Original Article 1, 3 Assoc. Professor 2 Professor & HOD 4, 5 PG Students Department of Orthopedics MGM Hospital Kakatiya Medical College Warangal. Telangana State India. CORRESPONDENCE : Dr.Jhatosh.Venkateshwarlu,

More information

MINIMALLY INVASIVE PLATE OSTEOSYNTHESIS FOR DISTAL RADIUS FRACTURES: SURGICAL TECHNIQUE M. TOBE 1, K. MIZUTANI 1, Y. TSUBUKU 1, Y.

MINIMALLY INVASIVE PLATE OSTEOSYNTHESIS FOR DISTAL RADIUS FRACTURES: SURGICAL TECHNIQUE M. TOBE 1, K. MIZUTANI 1, Y. TSUBUKU 1, Y. Riv Chir Mano - Vol. 43 (3) 2006 MINIMALLY INVASIVE PLATE OSTEOSYNTHESIS FOR DISTAL RADIUS FRACTURES: SURGICAL TECHNIQUE M. TOBE 1, K. MIZUTANI 1, Y. TSUBUKU 1, Y. YANAGIHARA 2 1 Department of 2nd Orthopaedic

More information

COMPARATIVE STUDY OF FUNCTIONAL OUTCOME OF EXTERNAL AND INTERNAL FIXATION IN TREATMENT OF COMMINUTED DISTAL RADIUS FRACTURES

COMPARATIVE STUDY OF FUNCTIONAL OUTCOME OF EXTERNAL AND INTERNAL FIXATION IN TREATMENT OF COMMINUTED DISTAL RADIUS FRACTURES COMPARATIVE STUDY OF FUNCTIONAL OUTCOME OF EXTERNAL AND INTERNAL FIXATION IN TREATMENT OF COMMINUTED DISTAL RADIUS FRACTURES R. Sahaya Jose 1 1Assistant Professor, Department of Orthopaedics, Sree Mookambika

More information

Index. Note: Page numbers of article titles are in boldface type. Hand Clin 21 (2005)

Index. Note: Page numbers of article titles are in boldface type. Hand Clin 21 (2005) Hand Clin 21 (2005) 501 505 Index Note: Page numbers of article titles are in boldface type. A Antibiotics, following distal radius fracture treatment, 295, 296 Arthritis, following malunion of distal

More information

Treatment of unstable distal radius fractures with the volar locking plate

Treatment of unstable distal radius fractures with the volar locking plate Upsala Journal of Medical Sciences. 2011; 116: 280 284 ORIGINAL ARTICLE Treatment of unstable distal radius fractures with the volar locking plate HANAE MINEGISHI 1, OSAMU DOHI 1, SOUKAN AN 2 & HIDETSUGU

More information

JMSCR Vol 05 Issue 06 Page June 2017

JMSCR Vol 05 Issue 06 Page June 2017 www.jmscr.igmpublication.org Impact Factor 5.84 Index Copernicus Value: 83.27 ISSN (e)-2347-176x ISSN (p) 2455-0450 DOI: https://dx.doi.org/10.18535/jmscr/v5i6.32 Functional & Radiological Outcome of the

More information

Management of intra-articular fractures of distal end radius in adults

Management of intra-articular fractures of distal end radius in adults International Journal of Research in Orthopaedics Gawali SR et al. Int J Res Orthop. 2016 Dec;2(4):220-228 http://www.ijoro.org Original Research Article DOI: http://dx.doi.org/10.18203/issn.2455-4510.intjresorthop20163148

More information

A STUDY OF THE FUNCTIONAL OUTCOME OF LOW PROFILE DORSAL PLATING IN DISTAL END RADIUS FRACTURES

A STUDY OF THE FUNCTIONAL OUTCOME OF LOW PROFILE DORSAL PLATING IN DISTAL END RADIUS FRACTURES Original Article Orthopaedics A STUDY OF THE FUNCTIONAL OUTCOME OF LOW PROFILE DORSAL PLATING IN DISTAL END RADIUS FRACTURES Sunil H. Shetty 1, Amit B. Dhond 2, Manavdeep Singh 3, Atul Kharat 4, Abhimanyu

More information

Fractures of the distal end of the radius should be

Fractures of the distal end of the radius should be FRACTURES OF THE DISTAL END OF THE RADIUS TREATED BY INTERNAL FIXATION AND EARLY FUNCTION A PRELIMINARY REPORT OF 20 CASES DANIEL A. RIKLI, PIETRO REGAZZONI From the University Hospital, Basel, Switzerland

More information

Complications of Distal Radius Fractures. How to Treat a Distal Radius Fx 11/13/2017. Michael S. Bednar, M.D. Loyola University Chicago

Complications of Distal Radius Fractures. How to Treat a Distal Radius Fx 11/13/2017. Michael S. Bednar, M.D. Loyola University Chicago Complications of Distal Radius Fractures Michael S. Bednar, M.D. Loyola University Chicago How to Treat a Distal Radius Fx Need to restore motion, begin with uninvolved parts Need to reduce an unreduced

More information

Volar fixed-angle plating for distal radius fractures 刀圭会協立病院 津村敬

Volar fixed-angle plating for distal radius fractures 刀圭会協立病院 津村敬 Volar fixed-angle plating for distal radius fractures 刀圭会協立病院 津村敬 Normal distal radius anatomy Radial styloid process EPL Volar lip Lister s s tubercle Radial styloid process Sigmoid notch palmar view

More information

ORIGINAL ARTICLE TREATMENT DISTAL RADIUS FRACTURE WITH VOLAR BUTTRESS TECHNIQUE- A CLINICAL STUDY

ORIGINAL ARTICLE TREATMENT DISTAL RADIUS FRACTURE WITH VOLAR BUTTRESS TECHNIQUE- A CLINICAL STUDY TREATMENT DISTAL RADIUS FRACTURE WITH VOLAR BUTTRESS TECHNIQUE- A CLINICAL STUDY Neelanagowda V P Patil 1, Lingaraj 2, P S Kaladagi 3, Paramanda Hospeti 4, Nizamuddin 5. 1. Assistant professor, Department

More information

Disclosure. 85% Dorsal. 15% Volar. Distal Radius Fractures- Volar Plating for All. Skeletal Dynamics- Consultant

Disclosure. 85% Dorsal. 15% Volar. Distal Radius Fractures- Volar Plating for All. Skeletal Dynamics- Consultant Distal Radius Fractures- Volar Plating for All Frontiers in Upper Extremity Surgery 2017 Francisco Rubio, M.D. Miami Hand and Upper Extremity Institute Miami, FL Disclosure Skeletal Dynamics- Consultant

More information

ORIGINAL ARTICLE. possible. Accurate assessment of standard radiographs is essential for appropriate 3. management. And includes true posterior- 4

ORIGINAL ARTICLE. possible. Accurate assessment of standard radiographs is essential for appropriate 3. management. And includes true posterior- 4 ORIGINAL ARTICLE Treatment of Colle's Fracture with Wrist Immobilization in Palmar flexed & Dorsiflexed Position Sohail Iqbal Shaikh, Abdul Basit, Javed Iqbal, Saba Sohail Shaikh, Imran Sohail Shaikh 26

More information

Emile N. Brown, MD, and Scott D. Lifchez, MD

Emile N. Brown, MD, and Scott D. Lifchez, MD Flexor Pollicis Longus Tendon Rupture After Volar Plating of a Distal Radius Fracture: Pronator Quadratus Plate Coverage May Not Adequately Protect Tendons Emile N. Brown, MD, and Scott D. Lifchez, MD

More information

Non-comminuted extra-articular fractures of distal radius treated with Percutaneous pinning

Non-comminuted extra-articular fractures of distal radius treated with Percutaneous pinning Original article: Non-comminuted extra-articular fractures of distal radius treated with Percutaneous pinning Manikandan K, Khisankumar PN, Arunprasath.C Department of orthopedics, Kalitheerthalkuppam,

More information

Variable Angle LCP Volar Rim Distal Radius Plate 2.4. For fragment-specific fracture fixation with variable angle locking technology.

Variable Angle LCP Volar Rim Distal Radius Plate 2.4. For fragment-specific fracture fixation with variable angle locking technology. Technique Guide Variable Angle LCP Volar Rim Distal Radius Plate 2.4. For fragment-specific fracture fixation with variable angle locking technology. Image intensifier control Warning This description

More information

The Wrist Fusion Set. Stainless Steel and Titanium TECHNIQUE GUIDE. Instruments and implants approved by the AO Foundation

The Wrist Fusion Set. Stainless Steel and Titanium TECHNIQUE GUIDE. Instruments and implants approved by the AO Foundation The Wrist Fusion Set Stainless Steel and Titanium TECHNIQUE GUIDE Instruments and implants approved by the AO Foundation Three Plate Options Stainless Steel or Titanium* Standard Bend Stainless Steel [242.510]

More information

Operative Treatment of Intra-articular Distal Radius Fractures Using the Small AO External Fixation Device

Operative Treatment of Intra-articular Distal Radius Fractures Using the Small AO External Fixation Device ORIGINAL ARTICLE Operative Treatment of Intra-articular Distal Radius Fractures Using the Small AO External Fixation Device Teng-Le Huang 1,2 *, Ching-Kuei Huang 2,3, Jung-Kuang Yu 2,3, Fang-Yao Chiu 2,3,

More information

journal ORIGINAL RESEARCH

journal ORIGINAL RESEARCH texas orthopaedic journal ORIGINAL RESEARCH Assessment of Volar Tilt Measurements with Variations in X-Ray Beam Centralization Along the Longitudinal Axis of the Radius Russell A. Wagner, MD; Will Junius,

More information

Disclosures. Distal Radius Fractures 5/16/2017. Distal Radius Fractures: Complications & Limitations of the Volar Approach

Disclosures. Distal Radius Fractures 5/16/2017. Distal Radius Fractures: Complications & Limitations of the Volar Approach Distal Radius Fractures: Complications & Limitations of the Volar Approach Frank R. Avilucea, MD Assistant Professor Department of Orthopaedic Surgery University of Cincinnati Medical Center Disclosures

More information

JMSCR Vol 05 Issue 04 Page April 2017

JMSCR Vol 05 Issue 04 Page April 2017 www.jmscr.igmpublication.org Impact Factor 5. Index Copernicus Value: 3.7 ISSN (e)-37-17x ISSN (p) 55-5 DOI: https://dx.doi.org/1.1535/jmscr/v5i.1 Functional Outcome after Surgical Stabilization of Fractures

More information

Clinical Study Dorsally Comminuted Fractures of the Distal End of the Radius: Osteosynthesis with Volar Fixed Angle Locking Plates

Clinical Study Dorsally Comminuted Fractures of the Distal End of the Radius: Osteosynthesis with Volar Fixed Angle Locking Plates ISRN Orthopedics Volume 2013, Article ID 131757, 6 pages http://dx.doi.org/10.1155/2013/131757 Clinical Study Dorsally Comminuted Fractures of the Distal End of the Radius: Osteosynthesis with Volar Fixed

More information

Instrument and Implant for wrist fracture

Instrument and Implant for wrist fracture Instrument and Implant for wrist fracture Jansri Janpanya Product specialist The Bangkok Unitrade Co,.ltd. Objectives Type of LCP for distal radius Fx. The new LCP design for distal radius Fx. Have knowledge

More information

Intra articular distal radius fractures and volar plate fixation: a prospective study

Intra articular distal radius fractures and volar plate fixation: a prospective study International Journal of Research in Orthopaedics Kundu AK et al. Int J Res Orthop. 2017 May;3(3):589-594 http://www.ijoro.org Original Research Article DOI: http://dx.doi.org/10.18203/issn.2455-4510.intjresorthop20171907

More information

Wrist Fusion Instrument and Implant Set.

Wrist Fusion Instrument and Implant Set. Wrist Fusion Instrument and Implant Set. Surgical Technique Discontinued December 2016 DSEM/TRM/0815/0479(2) This publication is not intended for distribution in the USA. Instruments and implants approved

More information

Hand and wrist emergencies

Hand and wrist emergencies Chapter1 Hand and wrist emergencies Carl A. Germann Distal radius and ulnar injuries PEARL: Fractures of the distal radius and ulna are the most common type of fractures in patients younger than 75 years.

More information

VOLAR LOCKING COMPRESSION SYSTEM DISTAL AND RADIUS FRACTURE DISSERTATION

VOLAR LOCKING COMPRESSION SYSTEM DISTAL AND RADIUS FRACTURE DISSERTATION VOLAR LOCKING COMPRESSION SYSTEM DISTAL AND RADIUS FRACTURE DISSERTATION A COMPARATIVE STUDY FOR MANAGEMENT OF DISTAL END RADIUS FRACTURE WITH VOLAR LOCKING COMPRESSION SYSTEM UNIVERSITY OF SEYCHELLES

More information

2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology. Technique Guide 2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology. Table of Contents Introduction 2.4

More information

Complications and functional outcome following fixation of complex, intra-articular fractures of the distal radius with the AO Pi-Plate

Complications and functional outcome following fixation of complex, intra-articular fractures of the distal radius with the AO Pi-Plate Acta Orthop. Belg., 2005, 71, 672-677 ORIGINAL STUDY Complications and functional outcome following fixation of complex, intra-articular fractures of the distal radius with the AO Pi-Plate Vikas KHANDUJA,

More information

WINSTA-R. Distal Radius System

WINSTA-R. Distal Radius System Distal Radius System Table of Contents Introduction WINSTA-R System 2 Indication 2 Surgical Technique Palmar Access for Radius Plate 3 Dorsal Access for Radius Plate 3 Positioning of the Radius Plate

More information

Fractures of the distal radius have occupied a storied history

Fractures of the distal radius have occupied a storied history Distal Radius Fractures: What Cannot Be Fixed With a Volar Plate? The Role of Fragment-Specific Fixation in Modern Fracture Treatment Jonathan Lam, MD, PhD,* and Scott W. Wolfe, MD, The advent of volar

More information

CASE REPORT. Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report

CASE REPORT. Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report Nagoya J. Med. Sci. 79. 551 ~ 557, 2017 doi:10.18999/nagjms.79.4.551 CASE REPORT Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report Takaaki Shinohara 1

More information

University of Groningen. Fracture of the distal radius Oskam, Jacob

University of Groningen. Fracture of the distal radius Oskam, Jacob University of Groningen Fracture of the distal radius Oskam, Jacob IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from it. Please check the document

More information

A prospective study of surgical management of distal radius fracture in adult with plate fixation

A prospective study of surgical management of distal radius fracture in adult with plate fixation 2017; 3(3): 236-240 ISSN: 2395-1958 IJOS 2017; 3(3): 236-240 2017 IJOS www.orthopaper.com Received: 14-05-2017 Accepted: 15-06-2017 Dr. Jagadeesh Babu Somesula MS (Orthopaedics), Assistant RVM Institute

More information

Distal Radius Plate 2.4/2.7 dorsal and volar

Distal Radius Plate 2.4/2.7 dorsal and volar Distal Radius Plate 2.4/2.7 dorsal and volar Surgical Technique This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation. Distal Radius Plate

More information

Characteristics of two different locking compression plates in the volar fixation of complex articular distal radius fractures

Characteristics of two different locking compression plates in the volar fixation of complex articular distal radius fractures Characteristics of two different locking compression plates in the volar fixation of complex articular distal radius fractures The Harvard community has made this article openly available. Please share

More information

Evaluation of volar locking plate fixation for management of intraarticular fractures of distal end of radius

Evaluation of volar locking plate fixation for management of intraarticular fractures of distal end of radius International Journal of Research in Orthopaedics Pathak RS et al. Int J Res Orthop. 2018 Mar;4(2):193-197 http://www.ijoro.org Original Research Article DOI: http://dx.doi.org/10.18203/issn.2455-4510.intjresorthop20180400

More information

A Patient s Guide to Adult Distal Radius (Wrist) Fractures

A Patient s Guide to Adult Distal Radius (Wrist) Fractures A Patient s Guide to Adult Distal Radius (Wrist) Fractures Suite 11-13/14/15 Mount Elizabeth Medical Center 3 Mount Elizabeth Singapore, 228510 Phone: (65) 6738 2628 Fax: (65) 6738 2629 1 DISCLAIMER: The

More information

EVIDENCE BASED MEDICINE. Pennig Dynamic Wrist Fixator

EVIDENCE BASED MEDICINE. Pennig Dynamic Wrist Fixator EVIDENCE BASED MEDICINE Pennig Dynamic Wrist Fixator I 1.PRODUCT OVERVIEW Orthofix approach to Evidence Based Medicine For years, clinical decision-making was based primarily on physician knowledge and

More information

Paresh Patil, Kiran Gaonkar, Adish Patil, Nishant Gaonkar, Ketan Gupta*, Nirav Patel, Himanshu Kulkarni

Paresh Patil, Kiran Gaonkar, Adish Patil, Nishant Gaonkar, Ketan Gupta*, Nirav Patel, Himanshu Kulkarni International Journal of Research in Medical Sciences Patil P et al. Int J Res Med Sci. 2015 Apr;3(4):883-890 www.msjonline.org pissn 2320-6071 eissn 2320-6012 Research Article DOI: 10.5455/2320-6012.ijrms20150412

More information

ORIGINAL ARTICLE FUNCTIONAL OUTCOME OF UNSTABLE DISTAL RADIUS FRACTURES - TREATED BY PERCUTANEOUS K-WIRE FIXATION

ORIGINAL ARTICLE FUNCTIONAL OUTCOME OF UNSTABLE DISTAL RADIUS FRACTURES - TREATED BY PERCUTANEOUS K-WIRE FIXATION FUNCTIONAL OUTCOME OF UNSTABLE DISTAL RADIUS FRACTURES - TREATED BY PERCUTANEOUS K-WIRE FIXATION Chatla Srinivas 1, Kali Vara Prasad Vadlamani 2, G. V. S. Moorthy 3, P. Satish 4, T. Narasimha Rao 5, Vamshi

More information

Failed Extensor Indicis Proprius Tendon Transfer for Extensor Pollicis Longus Tendon Rupture after Distal Radial Fracture

Failed Extensor Indicis Proprius Tendon Transfer for Extensor Pollicis Longus Tendon Rupture after Distal Radial Fracture CASE REPORT pissn 1598-3889 eissn 2234-0998 J Korean Soc Surg Hand 2015;20(1):23-27. http://dx.doi.org/10.12790/jkssh.2015.20.1.23 JOURNAL OF THE KOREAN SOCIETY FOR SURGERY OF THE HAND Failed Extensor

More information

Breakage of a volar locking plate after delayed union of a distal radius fracture

Breakage of a volar locking plate after delayed union of a distal radius fracture cta Orthop. elg., 2007, 73, 785-790 CSE REPORT reakage of a volar locking plate after delayed union of a distal radius fracture Tom DE ERE, Frédéric LECOUVET, Olivier RIER From Cliniques Universitaires

More information

Korean Type Distal Radius Anatomical Volar Plate System: A Preliminary Report

Korean Type Distal Radius Anatomical Volar Plate System: A Preliminary Report Original Article Clinics in Orthopedic Surgery 2014;6:258-266 http://dx.doi.org/10.4055/cios.2014.6.3.258 Korean Type Distal Radius Anatomical Volar Plate System: A Preliminary Report Jeong Hwan Kim, MD,

More information

6/5/2018. DISCLOSURES Hassan R. Mir, MD, MBA, FACS. Evolution of Distal Radius Fracture Treatment [Chung Hand Clinics 2012]

6/5/2018. DISCLOSURES Hassan R. Mir, MD, MBA, FACS. Evolution of Distal Radius Fracture Treatment [Chung Hand Clinics 2012] DISCLOSURES Hassan R. Mir, MD, MBA, FACS Paid Consultant for a Company or Supplier Smith & Nephew Zimmer Biomet Trice Medical Stock or Stock Options Core Orthopaedics OrthoGrid Systems Research Support

More information

Injury, Int. J. Care Injured 42 (2011) Contents lists available at ScienceDirect. Injury. journal homepage:

Injury, Int. J. Care Injured 42 (2011) Contents lists available at ScienceDirect. Injury. journal homepage: Injury, Int. J. Care Injured 42 (2011) 385 392 Contents lists available at ScienceDirect Injury journal homepage: www.elsevier.com/locate/injury Comparison of angle stable plate fixation approaches for

More information

INTERNAL FIXATION OF THE METACARPALS AND PHALANGES P. BURGE

INTERNAL FIXATION OF THE METACARPALS AND PHALANGES P. BURGE Riv Chir Mano - Vol. 43 (3) 2006 INTERNL FIXTION OF THE METCRPLS ND PHLNGES P. URGE Nuffield Orthopaedic Centre, Oxford, UK SUMMRY Techniques and instrumentation for open reduction and internal fixation

More information

Factors Predicting Late Collapse of Distal Radius Fractures

Factors Predicting Late Collapse of Distal Radius Fractures http://dx.doi.org/10.5704/moj.1111.006 Factors Predicting Late Collapse of Distal Radius Fractures, MD Regional Hospital Durres, Orthopaedic Clinic, Durres, Albania ABSTRACT Background: Although fractures

More information

Orthopedics in Motion Tristan Hartzell, MD January 27, 2016

Orthopedics in Motion Tristan Hartzell, MD January 27, 2016 Orthopedics in Motion 2016 Tristan Hartzell, MD January 27, 2016 Humerus fractures Proximal Shaft Distal Objectives 1) Understand the anatomy 2) Epidemiology and mechanisms of injury 3) Types of fractures

More information

Acute Rupture of Flexor Tendons as a Complication of Distal Radius Fracture

Acute Rupture of Flexor Tendons as a Complication of Distal Radius Fracture 60 pissn : 1226-2102, eissn : 2005-8918 Case Report J Korean Orthop Assoc 2015;50: 60-65 http://dx.doi.org/10.4055/jkoa.2015.50.1.60 www.jkoa.org Acute Rupture of Flexor Tendons as a Complication of Distal

More information

Comparison between Distractor Application on Both Radial & Ulnar Side and Radial Side Only for Fracture Distal Radius with Ulnar Styloid Fracture

Comparison between Distractor Application on Both Radial & Ulnar Side and Radial Side Only for Fracture Distal Radius with Ulnar Styloid Fracture Open Journal of Orthopedics, 2013, 3, 227-233 http://dx.doi.org/10.4236/ojo.2013.35043 Published Online September 2013 (http://www.scirp.org/journal/ojo) 227 Comparison between Distractor Application on

More information

UZZAMAN KS 1, AWAL KA 2, ALAM MK 3

UZZAMAN KS 1, AWAL KA 2, ALAM MK 3 CLOSED REDUCTION AND PERCUTANEOUS KIRSCHNER WIRE FIXATION COMBINED WITH PLASTER CAST VERSUS CONVENTIONAL PLASTER CAST IMMOBILIZATION IN THE TREATMENT OF COLLES FRACTURE A PROSPECTIVE RANDOMIZED COMPARATIVE

More information

IS CASTING AN ACCEPTABLE TREATMENT APPROACH FOR A DISTAL RADIUS FRACTURE THAT HAS UNDERGONE A SATISFACTORY CLOSED REDUCTION?

IS CASTING AN ACCEPTABLE TREATMENT APPROACH FOR A DISTAL RADIUS FRACTURE THAT HAS UNDERGONE A SATISFACTORY CLOSED REDUCTION? Original Article FOR A DISTAL RADIUS FRACTURE THAT HAS UNDERGONE A SATISFACTORY CLOSED REDUCTION? Khalid Masood *, Muhammad Jamil **, Farooq Ibrahim Pasha*, Khalid Zulfiqar Quresshi **, Naveed Ishaq Malik

More information

Outcome of Augmented External Fixation of Unstable Distal Radius Fractures

Outcome of Augmented External Fixation of Unstable Distal Radius Fractures Original Article Outcome of Augmented External Fixation of Unstable Distal Radius Fractures Noor Akbar Sial, Muhammad Javaid Iqbal, Muhammad Kaleem Shaukat ABSTRACT Background: Well-reduced unstable distal

More information

QUICK REFERENCE GUIDE. The Pennig Dynamic Wrist Fixator. Part A: Trans-articular application

QUICK REFERENCE GUIDE. The Pennig Dynamic Wrist Fixator. Part A: Trans-articular application 10 The Pennig Dynamic Wrist Fixator Part A: Trans-articular application B1 B2 B3 III IV TRANS-ARTICULAR APPLICATION The fractures that can be treated with this technique include AO type B and C fractures,

More information

Therapeutic Effects of Volar Anatomical Plates Versus Locking Plates for Volar Barton s Fractures

Therapeutic Effects of Volar Anatomical Plates Versus Locking Plates for Volar Barton s Fractures n Feature Article Therapeutic Effects of Volar Anatomical Plates Versus Locking Plates for Volar Barton s Fractures Zhibing Tang, MD; Huilin Yang, MD, PhD; Kangwu Chen, MD; Genlin Wang, MD, PhD; Xiaoyu

More information

Mark VanDer Kaag 1, Ajmal Ikram 2. Hand Unit, Tygerberg Hospital University of Stellenbosch

Mark VanDer Kaag 1, Ajmal Ikram 2. Hand Unit, Tygerberg Hospital University of Stellenbosch A Prospective, Randomized Controlled Study To Determine The Radiological And Functional Outcomes Of IMN Fixation Of Distal Radius Fractures Using A Novel Device The Sonoma Wrx Distal Radius Nail Compared

More information

Indian Journal of Basic and Applied Medical Research; December 2015: Vol.-5, Issue- 1, P

Indian Journal of Basic and Applied Medical Research; December 2015: Vol.-5, Issue- 1, P Original article Study of outcome of various modalities for treatment for distal end radius fracture Ashish Somani 1, Uday Mahajan 2, Sanjay Mulay 3, Nikhil Suri 2 1Associate Professor, 2 Third Year Junior

More information

Technique Guide. Rotation Correction Plates 1.5 and 2.0. Reposition plates for fractures and osteotomies at the metacarpals and phalanges.

Technique Guide. Rotation Correction Plates 1.5 and 2.0. Reposition plates for fractures and osteotomies at the metacarpals and phalanges. Technique Guide Rotation Correction Plates 1.5 and 2.0. Reposition plates for fractures and osteotomies at the metacarpals and phalanges. Table of Contents Introduction Rotation Correction Plates 1.5

More information

Angle Stable Distal Radial Plate System WINSTA-R

Angle Stable Distal Radial Plate System WINSTA-R Angle Stable Distal Radial Plate System WINSTA-R Priv.-Doz.Dr.med. Martin Walz Dr. med. Felix Menzinger Prof.Dr.med. Jürgen Rudigier www.marquardt-medizintechnik.de General The problem posed by metaphyseal

More information

4 mm cannulatedcancellous screws fixation in extra articular distal 1/3 radius fracture - A study

4 mm cannulatedcancellous screws fixation in extra articular distal 1/3 radius fracture - A study Al Am een J Med Sci 2017; 10(1): 49-55 US National Library of Medicine enlisted journal ISSN 0974-1143 ORIGI NAL ARTICLE C O D E N : A A J MB G 4 mm cannulatedcancellous screws fixation in extra articular

More information

Long-term Results of Dorsally Displaced Distal Radius Fractures Treated With the Pi-Plate: Is Hardware Removal Necessary?

Long-term Results of Dorsally Displaced Distal Radius Fractures Treated With the Pi-Plate: Is Hardware Removal Necessary? Long-term Results of Dorsally Displaced Distal Radius Fractures Treated With the Pi-Plate: Is Hardware Removal Necessary? MINOS E. TYLLIANAKIS, MD; ANDREAS M. PANAGOPOULOS, MD, PHD; ALKIS SARIDIS, MD abstract

More information

Index. Springer International Publishing Switzerland 2016 J.N. Lawton (ed.), Distal Radius Fractures, DOI /

Index. Springer International Publishing Switzerland 2016 J.N. Lawton (ed.), Distal Radius Fractures, DOI / Index A AAOS. See American Academy of Orthopaedic Surgeons (AAOS) Abductor pollicis longus (APL) tendon, 34, 73 Acute carpal tunnel syndrome, 93 American Academy of Orthopaedic Surgeons (AAOS), 66, 238

More information

LCP Wrist Fusion Set. Anatomic plates for total wrist fusion.

LCP Wrist Fusion Set. Anatomic plates for total wrist fusion. LCP Wrist Fusion Set. Anatomic plates for total wrist fusion. Technique Guide This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation. Table

More information

University of Groningen. Fracture of the distal radius Oskam, Jacob

University of Groningen. Fracture of the distal radius Oskam, Jacob University of Groningen Fracture of the distal radius Oskam, Jacob IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from it. Please check the document

More information

Comparative Study between Bridging External Fixation vs Volar Plating (Ellis-T Plate) for Comminuted Fracture of the Distal End Radius

Comparative Study between Bridging External Fixation vs Volar Plating (Ellis-T Plate) for Comminuted Fracture of the Distal End Radius SK Venkatesh Gupta, Pradeep Mandapalli Clinical study 10.5005/jp-journals-10017-1051 Comparative Study between Bridging External Fixation vs Volar Plating (Ellis-T Plate) for Comminuted Fracture of the

More information

Augmented external fixation of unstable distal radius fractures :

Augmented external fixation of unstable distal radius fractures : Rankin et al. The Journal HAND. Parkinson RW, Hodgkinson JP, Hargadon EJ. Symptom.. atic non-union of the carpal scaphoid: Matti-Russe bone: grafting versus Herbert screw fixation. Injury 989;0:6-6.. Parren

More information

Wrist Fixation System

Wrist Fixation System Wrist Fixation System Anatomy / Fracture Implant EXTRA & SIMPLE ARTICULAR Volar Radius Volar Fixed Angle Plate Volar Bearing Plate Radial Peg Plate Volar Hook Plate Volar Buttress Pin Volar Shear Plate

More information

Kousuke Iba 1*, Yasuhiro Ozasa 1, Takuro Wada 1, Tomoaki Kamiya 1, Toshihiko Yamashita 1, Mitsuhiro Aoki 2. Abstract

Kousuke Iba 1*, Yasuhiro Ozasa 1, Takuro Wada 1, Tomoaki Kamiya 1, Toshihiko Yamashita 1, Mitsuhiro Aoki 2. Abstract RESEARCH ARTICLE Open Access Efficacy of radial styloid targeting screws in volar plate fixation of intra-articular distal radial fractures: a biomechanical study in a cadaver fracture model Kousuke Iba

More information

Acomparison of percutaneous and pin-and-plaster techniques in distal radius fracture

Acomparison of percutaneous and pin-and-plaster techniques in distal radius fracture Original Research Medical Journal of the Islamic Republic of Iran.Vol. 22, No. 4, February, 2009. pp. 159-163 Acomparison of percutaneous and pin-and-plaster techniques in distal radius fracture Farshid

More information

FUNCTIONAL AND RADIOLOGICAL OUTCOMES AFTER VOLAR LOCKING PLATE FIXATION IN TYPE C DISTAL RADIUS FRACTURES A RETROSPECTIVE STUDY

FUNCTIONAL AND RADIOLOGICAL OUTCOMES AFTER VOLAR LOCKING PLATE FIXATION IN TYPE C DISTAL RADIUS FRACTURES A RETROSPECTIVE STUDY FUNCTIONAL AND RADIOLOGICAL OUTCOMES AFTER VOLAR LOCKING PLATE FIXATION IN TYPE C DISTAL RADIUS FRACTURES A RETROSPECTIVE STUDY Surendra Singh Yadav 1, Vikas Singhal 2 1 - Associate Professor, Department

More information

Common Limb Fractures. Mr Sheraz Malik MB BS MRCS Instructor Mr Paul Ofori-Atta Mb ChB FRCS President Motc Life UK April 2009

Common Limb Fractures. Mr Sheraz Malik MB BS MRCS Instructor Mr Paul Ofori-Atta Mb ChB FRCS President Motc Life UK April 2009 Common Limb Fractures Mr Sheraz Malik MB BS MRCS Instructor Mr Paul Ofori-Atta Mb ChB FRCS President Motc Life UK April 2009 Objectives To be able to describe all characteristics of a fracture Describe

More information

Prospective Randomised Study of Intra-Articular Fractures of the Distal Radius: Comparison Between External Fixation and Plate Fixation

Prospective Randomised Study of Intra-Articular Fractures of the Distal Radius: Comparison Between External Fixation and Plate Fixation 600 Original Article Prospective Randomised Study of Intra-Articular Fractures of the Distal Radius: Comparison Between External Fixation and Plate Fixation Germaine GQ Xu, 1 MBBS, MMed (Surg), MRCS (Edin),

More information

Radiographic Evaluation of Dorsal Screw Penetration After Volar Fixed-Angle Plating of the Distal Radius: A Cadaveric Study

Radiographic Evaluation of Dorsal Screw Penetration After Volar Fixed-Angle Plating of the Distal Radius: A Cadaveric Study HAND (2007) 2:144 150 DOI 10.1007/s11552-007-9038-2 Radiographic Evaluation of Dorsal Screw Penetration After Volar Fixed-Angle Plating of the Distal Radius: A Cadaveric Study Steven D. Maschke & Peter

More information

Outcome of fracture distal radius treated with open reduction internal fixation with volar locking compression plate (A study of 50 cases)

Outcome of fracture distal radius treated with open reduction internal fixation with volar locking compression plate (A study of 50 cases) 2018; 4(1): 1003-1011 ISSN: 2395-1958 IJOS 2018; 4(1): 1003-1011 2018 IJOS www.orthopaper.com Received: 07-11-2017 Accepted: 10-12-2017 Dr. Umesh Nagrale DNB ortho. Senior resident. Department of Orthopaedics,

More information

Acute Wrist Injuries OUCH!

Acute Wrist Injuries OUCH! Acute Wrist Injuries OUCH! Case the athlete FOOSH from sporting event 2 days ago C/O wrist swelling, pain, worse with movement Hmmm Wrist pain Exam of the wrist - basics Appearance Swelling, bruising,

More information

5/9/2017. Distal Radius Fractures: What s New? What s New? Or Maybe New to you. Single Pak Sterile distal radius kits

5/9/2017. Distal Radius Fractures: What s New? What s New? Or Maybe New to you. Single Pak Sterile distal radius kits Distal Radius Fractures: What s New? What s New? Or Maybe New to you. Single Pak Sterile distal radius kits Extension of FCR split to release tendon for retraction Pronator Quadratus elevation with BR

More information

Indian Journal of Orthopaedics Surgery

Indian Journal of Orthopaedics Surgery 4 Indian Journal of Orthopaedics Surgery ISSN 2395-1354(Print) e-issn 2395-1362(Online) CLASSIFYING DISTAL RADIUS FRACTURES AND NEW YARDSTICK TO ORTHOPAEDIC RESIDENTS *Corresponding Author: Younis kamal

More information

University of Groningen. Fracture of the distal radius Oskam, Jacob

University of Groningen. Fracture of the distal radius Oskam, Jacob University of Groningen Fracture of the distal radius Oskam, Jacob IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from it. Please check the document

More information

Surgical technique. LCP Distal Radius System 2.4. Dorsal and volar plates for fractures and osteotomies of the distal radius.

Surgical technique. LCP Distal Radius System 2.4. Dorsal and volar plates for fractures and osteotomies of the distal radius. Surgical technique LCP Distal Radius System 2.4. Dorsal and volar plates for fractures and osteotomies of the distal radius. Contents AO ASIF Principles of Internal Fixation 4 Indications 5 Case Studies

More information

Union rate: Union: Stable 94% All fracture 90% Union after surgery for nonunion with surgery 80% OA in healed scaphoid: 9%

Union rate: Union: Stable 94% All fracture 90% Union after surgery for nonunion with surgery 80% OA in healed scaphoid: 9% Complications Incidence of Non-union 1 cm displacement of fracture caused 55% Non-union It takes 5-20 yrs to develop SNAC. SNAC appears to be more common with waist fracture than a proximal pole. However

More information

The Kienböck disease and scaphoid fractures. Mariusz Bonczar

The Kienböck disease and scaphoid fractures. Mariusz Bonczar The Kienböck disease and scaphoid fractures Mariusz Bonczar The Kienböck disease and scaphoid fractures Mariusz Bonczar Kienböck disease personal experience My special interest for almost 25 years Thesis

More information

Introduction. The wrist contains eight small carpal bones, which as a group act as a flexible spacer between the forearm and hand.

Introduction. The wrist contains eight small carpal bones, which as a group act as a flexible spacer between the forearm and hand. Wrist Introduction The wrist contains eight small carpal bones, which as a group act as a flexible spacer between the forearm and hand. Distal forearm Distal forearm 4 Distal end of the radius A. anterior

More information

The NBX Non-Bridging External Fixator A Non-Bridging External Fixator/Locking Plate capturing a series of.062mm K-wires and 3mm half-pins that are

The NBX Non-Bridging External Fixator A Non-Bridging External Fixator/Locking Plate capturing a series of.062mm K-wires and 3mm half-pins that are The NBX Non-Bridging External Fixator A Non-Bridging External Fixator/Locking Plate capturing a series of.062mm K-wires and 3mm half-pins that are inserted in a multiplanar and multi-directional fashion

More information

Distal Radius Plate Instrument and Implant Set. Discontinued December 2017 DSUS/TRM/0916/1063(1)

Distal Radius Plate Instrument and Implant Set. Discontinued December 2017 DSUS/TRM/0916/1063(1) Distal Radius Plate Instrument and Implant Set Surgical Technique Discontinued December 2017 DSUS/TRM/0916/1063(1) The Distal Radius Plates Indications For fixation of fractures and osteotomies, including

More information

Treatment of Distal Radial Fractures

Treatment of Distal Radial Fractures Treatment of Distal Radial Fractures Philippe Kopylov, Antonio Abramo, Ante Mrkonjic, and Magnus T agil Contents Introduction... 1676 Aetiology and Classification... 1677 History... 1677 Definition...

More information

University of Groningen. Fracture of the distal radius Oskam, Jacob

University of Groningen. Fracture of the distal radius Oskam, Jacob University of Groningen Fracture of the distal radius Oskam, Jacob IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from it. Please check the document

More information

Acute Rupture of Flexor Digitorum Profundus Tendon Associated with Distal Radius Fracture: A Case Report

Acute Rupture of Flexor Digitorum Profundus Tendon Associated with Distal Radius Fracture: A Case Report CASE REPORT pissn 1598-3889 eissn 2234-0998 J Korean Soc Surg Hand 2015;20(4):198-203. http://dx.doi.org/10.12790/jkssh.2015.20.4.198 JOURNAL OF THE KOREAN SOCIETY FOR SURGERY OF THE HAND Acute Rupture

More information

Technique Guide. VA-Locking Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis.

Technique Guide. VA-Locking Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis. Technique Guide VA-Locking Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis. Table of Contents Introduction VA-Locking Intercarpal Fusion System 2 Indications

More information

2.4 mm LCP Distal Radius System

2.4 mm LCP Distal Radius System A Comprehensive Plating System to Address a Variety of Fracture Patterns 2.4 mm LCP Distal Radius System Surgical Technique Table of Contents Introduction 2.4 mm LCP Distal Radius System 2 AO Principles

More information

Integra. Spider and Mini Spider Limited Wrist Fusion System SURGICAL TECHNIQUE

Integra. Spider and Mini Spider Limited Wrist Fusion System SURGICAL TECHNIQUE Integra Spider and Mini Spider Limited Wrist Fusion System SURGICAL TECHNIQUE Table of contents Description... 02 Indications... 02 Contraindications... 02 Surgical Technique... 03 Spider Introduction-Four

More information

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation. LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation. Technique Guide LCP Small Fragment System Table of Contents Introduction

More information

Fractures of distal end of Radius: A study on fracture reduction and stable fixation

Fractures of distal end of Radius: A study on fracture reduction and stable fixation IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-0853, p-issn: 2279-0861.Volume 16, Issue 6 Ver. X (June. 2017), PP 27-31 www.iosrjournals.org Fractures of distal end of Radius: A study

More information

Small External Fixator Wrist Spanning Frame. For the treatment of wrist fractures.

Small External Fixator Wrist Spanning Frame. For the treatment of wrist fractures. Small External Fixator Wrist Spanning Frame. For the treatment of wrist fractures. Technique Guide Part of the Small External Fixation System Small External Fixator Wrist Spanning Frame When to use The

More information

Carpal rows injuries!

Carpal rows injuries! Carpal rows injuries! Michael Papaloïzos! Center for Hand Surgery and Therapy Geneva, Switzerland no conflict of interest to declare Fractures of carpal bones! The fractured scaphoid! Fracture-dislocations

More information

MICRONAIL. Intramedullary Distal Radius System SURGICAL TECHNIQUE

MICRONAIL. Intramedullary Distal Radius System SURGICAL TECHNIQUE MICRONAIL II Intramedullary Distal Radius System SURGICAL TECHNIQUE Contents Introduction 3 4 Chapter 1 5 Chapter 2 6 Appendix A 18 Appendix B 19 Surgeon Design Team Introduction Product Information Surgical

More information

LISS DF and LISS PLT. Less Invasive Stabilization Systems for Distal Femur and Proximal Lateral Tibia.

LISS DF and LISS PLT. Less Invasive Stabilization Systems for Distal Femur and Proximal Lateral Tibia. LISS DF and LISS PLT. Less Invasive Stabilization Systems for Distal Femur and Proximal Lateral Tibia. LISS DF and LISS PLT. Less Invasive Stabilization Systems for Distal Femur and Proximal Lateral Tibia.

More information

Distal Radius and Distal Ulna Plates System Self-Tapping Spherical Locking Screw Self-Tapping Conical Locking Screw Cortex Screw

Distal Radius and Distal Ulna Plates System Self-Tapping Spherical Locking Screw Self-Tapping Conical Locking Screw Cortex Screw DISTAL RADIUS AND ULNA LOCKING PLATE SYSTEM Surgical Technique Distal Radius and Distal Ulna Plates System Self-Tapping Spherical Locking Screw Self-Tapping Conical Locking Screw Cortex Screw Approved

More information