Periprosthetic Fracture of the Femur after Total Hip Arthroplasty

Size: px
Start display at page:

Download "Periprosthetic Fracture of the Femur after Total Hip Arthroplasty"

Transcription

1 Periprosthetic Fracture of the Femur after Total Hip Arthroplasty TREATMENT AND RESULTS TO DATE*! BY DAVID G. LEWALLEN, M.D4, AND DANIEL J. BERRY, M.D4, ROCHESTER, MINNESOTA An Instructional Course Lecture, The American Academy of Orthopaedic Surgeons Postoperative periprosthetic femoral fractures have become increasingly common during the last decade. A wide range of problems, such as comminution and bone loss, are seen in association with these fractures, and the additional challenge of a loose femoral compotion of a long-stem femoral component for stabilization of the fracture; and bone-grafting with use of either autogenous grafts or allografts' l924J5: " ij8 ' 42 ' 45 ' 49-5 ' These fractures must be treated according to their individual characteristics, the status of the implant, associated 25 n 0-1 r \ F FIG. 1 Year BS CA B-01 Graph showing the number of postoperative fractures of the femur after ipsilateral total hip arthroplasty at the Mayo Clinic during a twenty-five-year period beginning in nent is commonly encountered. When a femoral fracture occurs in a patient in whom the femoral component is in place, reconstruction may be reasonably straightforward or it may be nearly impossible. Options for treatment have included the use of traction, casts, and external braces; operative reduction with internal fixation; numerous revision procedures involving inser- *Printed with permission of The American Academy of Orthopaedic Surgeons. This article will appear in Instructional Course Lectures, Volume 47, The American Academy of Orthopaedic Surgeons, Rosemont, Illinois, March tno benefits in any form have been received or will be received from a commercial party related directly or indirectly to the subject of this article. No funds were received in support of this study. ^Department of Orthopedics, Mayo Clinic, 200 First Street S.W., Rochester, Minnesota medical conditions, and the patient's level of physical activity 2 " Knowledge of the results in previously reported series and information regarding the range of treatment options can facilitate optimum decisionmaking with regard to these injuries. Prevalence of Postoperative Periprosthetic Femoral Fractures The number of patients who are seen with a postoperative periprosthetic fracture of the femur has increased steadily at our institution during the last twenty-five years (Fig. 1). Between 1989 and 1993, fracture was the second leading cause of revision hip arthroplasty at the Mayo Clinic, ranking after loosening of the implant and before dislocation and infection VOL. 79-A, NO. 12, DECEMBER

2 1882 D. G. LEWALLEN AND D. J. BERRY O >60 yrs. old <60 yrs. old O c in a i W 0 Bone Dislocation r^ Infection n_ tract. Loose FIG. 2 Other Prosthetic tract. Wear CA X-05 Bar graph showing the diagnoses that led to revision total hip arthroplasty at the Mayo Clinic between 1989 and Fracture was second only to loosening as a cause for revision, surpassing dislocation and infection. (Fig. 2). Reports have suggested an over-all prevalence of between 0.1 and 1.1 per cent, with ten postoperative periprosthetic fractures (0.2 per cent) found in 5400 patients in one of the largest series. However, these estimates apply to patients who had a femoral component that was inserted with cement and include both primary and revision total hip arthroplasties' 1S ' 30: " 4 ',.The time from the arthroplasty to the fracture ranged from six weeks to ten years in these reports. Lowenhielm et al., reporting on a series of 1442 primary hip arthroplasties performed with use of cement, calculated the cumulative postoperative risk of fracture to be 25.3 per 1000 at fifteen years 30. A survey of all records on total hip arthroplasties performed at the Mayo Clinic between 1969 and 1990, conducted with use of a computerized database from the Total Joint Registry, revealed a rate of femoral fracture of 0.6 per cent after 17,579 primary procedures performed with cement and a rate of 0.4 per cent after 2078 such procedures performed without cement during the same time-period. The rates were higher after revision procedures (2.8 per cent after 3265 procedures performed with cement compared with 1.5 per cent after 1132 procedures performed without cement). One factor that has contributed to the increased prevalence of periprosthetic femoral fractures is the greater proportion of the population that is at risk. It has been twenty-eight years since total hip arthroplasty was introduced in the United States; more than 120,000 primary procedures are carried out each year, and this FIG. 3-A FIG. 3-B Fig. 3-A: Radiograph of a hip that had loosening of the implant, osteolysis, and pain seven years after a total hip arthroplasty. The patient was advised to have a revision but refused. Fig. 3-B: Three months later, after a misstep, the patient sustained a periprosthetic fracture through an osteolytic defect. THE JOURNAL OF BONE AND JOINT SURGERY

3 PERIPROSTATIC FRACTURE OF THE FEMUR AFTER TOTAL HIP ARTHROPLASTY 1883 Other factors that have contributed to the greater prevalence of these fractures include an increase in the number of patients having revision hip arthroplasty and an increase in the number having more than one such procedure. Many of these revisions are related to the cumulative effects of particles of debris in the joint, as periprosthetic osteolysis increases the risk of fracture (Figs. 3-A and 3-B) 23 ' Radiograph showing a periprosthetic fracture through an area of cortical perforation and extravasation of cement at the time of a revision total hip arthroplasty. Bone-grafting of any defects and avoidance of extravasation of cement can reduce the risk of fracture across this type of stress-riser. number is growing steadily 38. In contrast to patterns of practice in the 1970s and the early 1980s, the indications for the procedure now include younger patients, heavier patients, and those who have severe bone loss 38. Treatment Prevention of fractures of the femur following total hip arthroplasty is preferable to even the most successful treatment options. Preventive measures that have been recommended for use during the initial arthroplasty include avoiding the creation of cracks, defects, or windows in the bone intraoperatively and, if these stress-risers are present, bypassing them with a stem of sufficient length that they end two to three cortical diameters distal to the defect 14 ' Extravasation of cement out of the bone defects should be avoided as this can facilitate subsequent fracture through the unhealed stress-riser (Fig. 4-A) 14. The use of cerclage wires for the fixation of periprosthetic cracks produced intraoperatively has been recommended to prevent propagation and a complete fracture 81 " Bone-grafting of defects also is recommended to allow resolution of the stressriser effect over time. Regular radiographic follow-up of all patients who have had a total hip arthroplasty is essential for the detection of major osteolytic defects that may lead to a periprosthetic fracture as well as to failure and loosen- FIG. 4-B Treatment in the presence of a well fixed stem consisted of insertion of a plate with screws distally and cerclage bands proximally, with bone-grafting of the fracture line and the defect. The patient eventually had a solid union. VOL. 79-A, NO. 12, DECEMBER 1997

4 1884 D. G. LEWALLEN AND D. J. BERRY stem inserted with cement; a long stem with proximal or extensive porous coating, inserted without cement; a composite consisting of an allograft and a prosthesis; a proximal femoral replacement stem; and a custom implant, stem sleeve, or extension' 2 -" ,33 ' 44 ' 45. Each of these options for revision can be combined with cancellous bone-grafting or with strut allograft in the region of the fracture (Fig. 5) 13. A construct consisting of an allograft and a prosthesis should be reserved for patients who have massive proximal femoral bone loss severe enough to preclude standard reconstruction (Figs. 6-A through 6-D)". In patients who have massive bone loss and a fracture, are more than seventy years of age, and place low demands on the hip, a modular proximal femoral replacement stem may be used (Fig. 7). The appropriate treatment for a patient must be determined on the basis of the availability of the materials needed for a particular method of reconstruction; the familiarity of the surgeon with the operative method; patient-related factors such as age, level of activity, bone quality, and configuration of the fracture; and the results that have been reported for the method under consideration 2 "' 25 ' ' 35 ' ' 54. FIG. 5 Intraoperative photograph showing onlay cortical strut allograft held with cerclage cables spanning a periprosthetic fracture. ing of the implant At our institution, all patients who have had an arthroplasty are followed with anteroposterior, lateral, and oblique radiographs at one, two, five, seven, and ten years postoperatively and every two to three years thereafter. Radiographs should be made more often if lysis develops or if other radiographic changes warrant increased surveillance. Many of the more challenging problems associated with periprosthetic fractures are due as much to inadequate radiographic follow-up as to the type of implant and the materials that were used. Revision is recommended before extensive bone loss and a resultant periprosthetic fracture have occurred, thereby obviating the need for more extensive operative treatment, which is associated with a greater risk of residual functional impairment. Periprosthetic fractures can be avoided only if regular radiographic follow-up is performed as recommended by the 1994 National Institutes of Health Consensus Conference on total hip replacement 38. Options for the treatment of postoperative periprosthetic femoral fractures have included protection of the fracture 12 ; traction ; use of casts and braces 35 ; and internal fixation with use of cerclage wires or cables 235, screws with and without plates 23550, and special plates that have claws, bands, or cerclage wires to allow fixation in the region of the intramedullary stem (Fig. 4-B) 10 ' Another option for treatment is revision of the femoral component, which is frequently necessary if the fracture occurs adjacent to a loose implant. These revisions have been performed with a Results of Treatment Johansson et al., in 1981, reported on a series of twenty-three intraoperative and fourteen postoperative periprosthetic femoral fractures 22. The fractures had FIG. 6-A Radiograph of a hip with loosening, osteolysis, and a periprosthetic fracture that was neglected because of inadequate medical and radiographic follow-up. THE JOURNAL OF BONE AND JOINT SURGERY

5 PERIPROSTATIC FRACTURE OF THE FEMUR AFTER TOTAL HIP ARTHROPLASTY 1885 W / * tit f // ' *' Fig. 6-B: Intraoperative photograph showing replacement of the damaged proximal aspect of the femur with a composite consisting of an allograft and a prosthesis. The procedure involved a step-cut osteotomy and cerclage wiring. The long stem of the femoral component spanned the site of the osteotomy. Fig. 6-C: The proximal femoral remnants and the trochanter were preserved and secured to the allograft to improve function and stability of the hip. been treated with various methods, including traction, internal fixation with cerclage wires and plates, revision with a long-stem implant, and resection arthroplasty. Of the fourteen postoperative fractures, eight were associated with complications. Only five of the arthroplasties that were followed by a postoperative fracture eventually yielded a satisfactory result 22. Bethea et al., in a subsequent report, noted an association between postoperative fracture and previous procedures on the hip or a loose implant 5. Of thirty-one hips that had a fracture four weeks to ten years after the arthroplasty, eighteen (58 per cent) had had at least two previous operations and twenty-three (74 per cent) had had loosening of the implant or osteolysis before the fracture. A number of methods were used for treatment; nonoperative treatment yielded the poorest results, whereas a revision with use of a long-stem prosthesis yielded the best results. Adolphson et al. reported the results of treatment of postoperative fracture in twenty-nine patients, twentyone of whom had been managed with traction and eight of whom had been managed operatively 1. This report is important because it emphasizes the high rate of complications associated with traction. Of the twentyone patients who had been managed with traction, six needed a subsequent operation because of malunion or malalignment, although all had healing of the original fracture. In contrast, three of the eight patients who had been managed operatively had a non-union'. Mont and Maar, in an effort to analyze the results in a larger number of patients, reviewed twenty-six ar- FIG. 6-D Radiograph showing the final construct. VOL. 79-A, NO. 12, DECEMBER 1997

6 1886 D. G. LEWALLEN AND D. J. BERRY FIG. 7 Photograph showing a modular proximal femoral replacement stem, which can be useful for the treatment of massive bone loss and a fracture of the proximal part of the femur. This implant is an alternative to the construct consisting of an allograft and a prosthesis, especially in an older patient. tides that had been published between 1964 and The 487 patients described in those articles were stratified according to the location of the periprosthetic fracture and the type of treatment. These authors did not distinguish between patients according to the status of the fixation before the fracture, according to whether a revision had been done with or without cement, according to whether or not bone-grafting had been done, or according to the type of graft. The fractures were categorized into five types on the basis of location, with supracondylar fractures constituting a sixth type. The rates of satisfactory results varied among the different types of fractures and the different methods of treatment. The result of traction was satisfactory for 57 per cent of the forty-six fractures that were located along the length of the stem, 43 per cent of the fifty-eight that were at the tip of the stem, and 77 per cent of the seventy-seven that were just distal to the tip of the stem. Treatment with cerclage wires alone was less successful when it was used for fractures distal to the tip of the stem than when it was used for more proximal fractures around the stem. The use of plates and screws was satisfactory treatment for seven of fifteen fractures occurring along the length of the stem, twelve (48 per cent) of twenty-five at the tip of the stem, and twentyeight (49 per cent) of fifty-seven distal to the tip of the stem 35. Beals and Tower reported the results of treatment of ninety-three fractures in eighty-six patients who had had an arthroplasty performed by one of thirty different orthopaedic surgeons 2. Nine fractures failed to heal; therefore, the results of 102 interventions were reported. (One fracture needed to be treated three times.) The average time to the fracture was 4.7 years; 38 per cent of the patients had had a previous fracture of a type commonly associated with osteoporosis. The etiology could be determined for eighty-two fractures. Eighty-four per cent were due to a fall; 8 per cent, trauma; and 8 per cent, spontaneous fracture. Before the fracture, the original implant had been a well fixed cemented stem (45 per cent), a loose cemented stem (23 per cent), an ingrowth implant (25 per cent), or an Austin-Moore-type stem (7 per cent). Of the 102 operative interventions elected by the operating surgeon, 34 per cent consisted of implantation of an ingrowth femoral stem; 15 per cent, revision to a stem inserted with cement; and 23 per cent, internal fixation with use of plates, screws, or lag screws. The remaining 28 per cent of the interventions were non-operative. Despite the extremely small number of interventions that were non-operative, complications were common, with traction resulting in a 45 per cent rate of malunion or marked shortening of the femur and an 11 per cent rate of non-union. The use of lag screws alone resulted in a new fracture at the site of the screw or a non-union after a few procedures. Fifteen per cent of the 102 procedures involving plate fixation resulted in a new fracture and another two procedures, in failure of the fixation. A prosthesis was inserted with cement for revision in an additional 15 per cent of the 102 procedures and was associated with a 31 per cent rate of non-union and a 15 per cent rate of refracture. A prosthesis was inserted without cement for revision in 34 per cent of the procedures and was associated with the best results in the series; shortening was noted after 7 per cent of the procedures and a new fracture, after 7 per cent, but the implant subsided after 18 per cent of the procedures. To analyze the results of treatment, Beals and Tower used a system based on the fixation of the stem and the healing status of the fracture. An excellent result was defined as a stable implant and a healed fracture; a good result, as a stable stem with some subsidence and a healed fracture with mild or moderate deformity; and a poor result, as a loose stem, non-union, deep infection, a new fracture, or severe deformity. In this cumulative series, 32 per cent of the interventions led to an excellent result; 16 per cent, a good result; and 52 per cent, a poor result 2. A recent review presented the results of revision total hip arthroplasty for the treatment of ninety-seven postoperative periprosthetic femoral fractures in ninetyfour patients who had been managed from 1971 to 1993 THE JOURNAL OF BONE AND JOINT SURGERY

7 PERIPROSTHETIC FRACTURE OF THE FEMUR AFTER TOTAL HIP ARTHROPLASTY 1887 at our institution. The average duration of follow-up was nearly five years (range, two to fourteen years); within two years, three implants had failed, three patients had died, and one patient had been lost to follow-up. The fractures were categorized with use of the Vancouver classification system", which defines trochanteric fractures as type A, fractures about the stem or the tip of the stem as type B, and fractures well distal to the tip as type C. Type-B fractures are further subdivided into those adjacent to a well fixed stem (type Bl), those adjacent to a loose stem (type B2), and those associated with marked osseous deficiency or destruction around the implant (type B3) n. Approximately 60 per cent of the fractures were type B2, and 25 per cent were type B3. Approximately 85 per cent of the fractures united, and 15 per cent did not. Stable long-term fixation of the stem was achieved in less than 50 per cent of the hips. Although more than 50 per cent of the hips had a loose femoral implant at the latest follow-up evaluation, more than 20 per cent had no pain or only minimum symptoms despite radiographic signs of subsidence or loosening. However, approximately 33 per cent had loosening and severe pain. Long-stem femoral components inserted with cement, proximally porous-coated long-stem components inserted without cement, and extensively porous-coated components inserted without cement all were used during the revision procedures. Insertion of a proximally porous-coated implant without cement was associated with the poorest results. An important observation was the development of a spontaneous fracture, in the absence of a fall or another inciting traumatic event, in more than 50 per cent of the patients who had a type-b3 fracture, in which bone loss and comminution are most severe; several of these patients had had no symptoms before the spontaneous fracture occurred. This finding reinforces the importance of regular radiographic follow-up after hip arthroplasty, in order to look for the massive bone loss characteristic of type-b3 fractures, which may be asymptomatic before catastrophic failure occurs. Recommendations for Treatment Of the available classification systems, we currently prefer the Vancouver system as it helps to guide treatment choices". The treatment of type-a fractures involving the greater or lesser trochanter depends on the underlying cause of the avulsion fracture. If the cause is severe periprosthetic osteolysis, then a revision is indicated to debride the osteolytic defects and to replace the component that is the source of the particles of debris, whereas simple avulsion of fragments of the greater or lesser trochanter in patients who have osteoporosis may be treated non-operatively in the presence of a well fixed stem. Type-Bl fractures, which, by definition, are associated with a well fixed stem, often can be treated with internal fixation. However, in patients who have a so-called first-generation implant and other problems related to the bearing surface or the position of the stem, revision may be preferable if it can be done without excessive bone damage. Type-C fractures (those well distal to a solidly fixed stem) are best treated with internal fixation unless they are minimally displaced and the position can be maintained with non-operative measures that do not require the patient to be recumbent for prolonged periods. All types of fractures associated with a loose femoral component are best treated with a revision, with possible rare exceptions dictated by unusual medical problems or advanced age. For all but the most debilitated patients, revision offers the best chance of achieving not only stable fixation and union of the fracture but also a functional hip and the highest overall level of function for the patient (Fig. 8). Radiographs made after ill advised closed treatment, with traction, of a periprosthetic fracture associated with a loose stem. Malunion and painful loosening mandated an extensive revision procedure despite what was considered to be a successful union by the treating physician after prolonged immobilization. VOL. 79-A, NO. 12, DECEMBER 1997

8 1888 D. G. LEWALLEN AND D. J. BERRY Radiograph made after onlay strut-grafting and use of an extensively porous-coated stem. This procedure resulted in fracturehealing and a stable implant. Several principles should be observed when a revision is performed for the treatment of a periprosthetic fracture. These include preservation of the bone stock whenever possible and achievement of stable fixation of the stem into intact host bone. This often necessitates distal fixation of the stem, which can be accomplished reliably with use of cement, with use of an extensively porous-coated stem, or with use of a stem that has grooves or slots if the diaphyseal bone segment References is relatively intact. When cement is used, care should be taken to prevent it from interdigitating into the fracture fragments as this can inhibit union. We have found that monobloc, proximally porous-coated, distally smooth femoral stems have performed poorly in routine revision situations 432. This disappointing experience has also been borne out in association with fractures. However, it is important to note that none of these situations involved stems with trochanteric bolts or distal slots and grooves, which have been designed for the enhanced stability of proximally coated implants. After a revision, cancellous bone-grafting of all fracture lines is recommended. Strut-grafting with cerclage wires is a reliable method for restoring osseous stability at the fracture site and for promoting union (Fig. 9). The use of a construct consisting of an allograft and a prosthesis or the use of a proximal femoral replacement stem should be reserved for hips with the most severe bone loss that cannot be reconstructed with standard methods. When either of these implants is used, it is helpful to preserve the proximal bone fragments and to wrap them around the component or the allograft, employing cerclage wires or cables in order to preserve the soft-tissue attachments, improve stability of the hip, and promote union. The use of a constrained acetabular insert or a bipolar articulation is reasonable when a proximal femoral replacement stem and a large allograft is used or when the presence of poor abductor and softtissue attachments proximally lead to concerns about stability. In conclusion, periprosthetic femoral fractures can present a major reconstructive challenge, but a wide variety of treatment options are available. Classification of the fracture, with assessment not only of its location but also of the fixation of the stem and the quality of the bone, allows a rational choice of reconstructive options for the management of these patients. 1. Adolphson, P.; Jonsson, U.; and Kalen, R.: Fractures of the ipsilateral femur after total hip arthroplasty. Arch. Orlhop. and Traumatic Surg., 106: , Beals, R. K., and Tower, S. S.: Periprosthetic fractures of the femur. An analysis of 93 fractures. Clin. Orlhop., 327: , Berman, A. T., and Levenberg, R. J.: Femur fractures associated with total hip arthroplasty. Orthopedics, 15: , Berry, D. J.; Harmsen, W. S.; Ilstrup, D.; Lewallen, D. G.; and Cabanela, M. E.: Survivorship of uncemented proximally porous-coated femoral components. Clin. Orthop., 319: , Bcthea, J. S., Ill; DeAndrade, J. R.; Fleming, L. L.; Lindenbaum, S. D.; and Welch, R. B.: Proximal femoral fractures following total hip arthroplasty. Clin. Orthop., 170: , Booth, R. E., Jr.: Management of periprosthetic fractures. Orthopedics, 17: , Charnley, J.: The healing of human fractures in contact with self-curing acrylic cement. Clin. Orthop., 47: , Christensen, C. M.; Seger, B. M.; and Schultz, R. B.: Management of intraoperative femur fractures associated with revision hip arthroplasty. Clin. Orthop., 248: , Cooke, P. H., and Newman, J. H.: Fractures of the femur in relation to cemented hip prostheses. J. Bone and Joint Surg., 70-B(3): , Dave, D. J.; Koka, S. R.; and James, S. E.: Mennen plate fixation for fracture of the femoral shaft with ipsilateral total hip and knee arthroplasties./ Arthroplasty, 10: , Duncan, C. P., and Masri, B. A.: Fractures of the femur after hip replacement. In Instructional Course lectures, The American Academy of Orthopaedic Surgeons. Vol. 44, pp Rosemont, Illinois, The American Academy of Orthopaedic Surgeons, Dysart, S. H.; Savory, C. G.; and Callaghan, J. J.: Nonoperative treatment of a postoperative fracture around an uncemented porouscoated femoral component../. Arthroplasty, 4: , Emerson, R. H., Jr.; Maliniii. T. I.; Cuellar, A. D.; Head, W. C; and Peters, P. C: Cortical strut allografts in the reconstruction of the femur in revision total hip arthroplasty. A basic science and clinical study. Clin. Orthop., 285: 35-44,1992. THE JOURNAL OF BONE AND JOINT SURGERY

9 PERIPROSTATIC FRACTURE OF THE FEMUR AFTER TOTAL HIP ARTHROPLASTY Eschenroeder, H. C, Jr., and Krackow, K. A.: Late onset femora] stress fracture associated with extruded cement following hip arthroplasty. A case report. Clin. Onhop., 236: , Federici, A.; Carbone, M.; and Sanguineti, F.: Intraoperative fractures of the femoral diaphysis in hip arthroprosthesis surgery. Italian J. Onhop. and Traumat., 14: , Fitzgerald, R. H., Jr.; Brindley, G. W.; and Kavanagh, B. F.: The uncemented total hip arthroplasty. Intraoperative femoral fractures. Clin. Onhop., 235:61-66, Fredin, H.: Late fracture of the femur following perforation during hip arthroplasty. A report of 2 cases. Acta Onhop. Scandinavica, 59: , Fredin, H. O.; Lindberg, H.; and Carlsson, A. S.: Femoral fracture following hip arthroplasty. Acta Orthop. Scandinavica, 58: 20-22, Garcia-Cimbrelo, E.; Munuera, L.; and Gil-Garay, E.: Femoral shaft fractures after cemented total hip arthroplasty. Jnternat. Onhop., 16: , Huo, M. H., and Keggi, K. J.: Periprosthetic femoral fracture treatment with an intramedullary extension sleeve../. Onhop. Tech., 2: , Jensen, T. T.; Overgaard, S.; and Mossing, N. B.: Partridge cerclene system for femoral fractures in osteoporotic bones with ipsilateral hemi/total arthroplasty../. Arthroplasty, 5: , Johansson, J. E.; McBroom, R.; Barrington, T. W.; and Hunter, G. A.: Fracture of the ipsilateral femur in patients with total hip replacement. J. Bone and Joint Surg., 63-A: , Dec Kelley, S. S.: Periprosthetic femoral fractures./. Am. Acad. Orthop. Surgeons, 2: , Kolstad, K.: Revision TH R after periprosthetic femoral fractures. An analysis of 23 cases. Acta Orthop. Scandinavica, 65: , Kraay, M. J.; Goldberg, V. M.; and Figgie, H. E., Ill: Use of an antibiotic impregnated polymethyl methacrylate intramedullary spacer for complicated revision total hip arthroplasty. J. Arthroplasty, 7 (Supplement): , Larson, J. E.; Chao, E. Y. S.; and Fitzgerald, R. H.: Bypassing femoral cortical defects with cemented intramedullary stems../. Orthop. Res., 9: , Levenberg, R.; Iorio, R.; Gingrich, K.; and Berlman, A. T.: Femur fractures associated with total hip arthroplasty. Orthopedics, 13:1185, , Lewallen, D. G., and Berry, D. J.: Femoral fractures associated with hip arthroplasty. In Reconstructive Surgery of the Joints, edited by B. F. Morrey. Ed. 2, vol. 2, pp New York, Churchill Livingstone, Lotke, P. A.; Wong, R. Y.; and Ecker, M. L.: Stress fracture as a cause of chronic pain following revision total hip arthroplasty. Report of two cases. Clin. Orthop., 206: , Lowenhielm, G.; Hansson, L. I.; and Karrholm, J.: Fracture of the lower extremity after total hip replacement. Arch. Orthop. and Trauma Surg., 108: , McElfresh, E. C, and Coventry, M. B.: Femoral and pelvic fractures after total hip arthroplasty../. Bone and Joint Surg., 56-A: , April Malkani, A. L.; Lewallen, D. G.; Cabanela, M. E.; and Wallrichs, S. L.: Femoral component revision using an uncemented, proximally coated, long-stem prosthesis. J. A rthroplasty, 11: , Mihalko, W. M.; Beaudoin, A. J.; Cardea, J. A.; and Krause, W. R.: Finite-element modelling of femoral shaft fracture fixation techniques post total hip arthroplasty../. Biomech., 25: , Missakian, M. L., and Rand, J. A.: Fractures of the femoral shaft adjacent to long stem femoral components of total hip arthroplasty: report of seven cases. Orthopedics, 16: , Mont, M. A., and Maar, D. C: Fractures of the ipsilateral femur after hip arthroplasty. A statistical analysis of outcome based on 487 patients../. Arthroplasty, 9: , Montijo, H.; Ebert, F. R.; and Lennox, D. A.: Treatment of proximal femur fractures associated with total hip arthroplasty../. Arthroplasty, 4: , Morrey, B. F., and Kavanagh, B. F.: Complications with revision of the femoral component of total hip arthroplasty. Comparison between cemented and uncemented techniques. J. Arthroplasty, 7: 71-79, National Institutes of Health Consensus Development Panel on Total Hip Replacement: National Institutes of Health Consensus Conference: total hip replacement. J. Am. Med. Assn., 273: , Ogden, W. S., and Rendall, J.: Fractures beneath hip prostheses: a special indication for Parham bands and plating. Orthop. Trans., 2: 70, Pankovich, A. M.; Tarabishy, I.; and Barmada, R.: Fractures below non-cemented femoral implants. Treatment with Ender nailing. J. Bone and Joint Surg., 63-A: , July Partridge, A. J., and Evans, P. E. L.: The treatment of fractures of the shaft of the femur using nylon cerclage../. Bone and Joint Surg., 64-B(2): , Pazzaglia, U., and Byers, P. D.: Fractured femoral shaft through an osteolytic lesion resulting from the reaction to a prosthesis. A case report. / Bone and Joint Surg., 66-B(3): , Radcliffe, S. N., and Smith, D. N.: The Mennen plate in periprosthetic hip fractures. Injury, 27: 27-30, Reich, S. M., and Jaffe, W. L.: Femoral fractures associated with loose cemented total hip arthroplasty. Orthopedics, 17: , Ries, M. D.: Intraoperative modular stem lengthening to treat periprosthetic femur fracture. J. Arthroplasty, 11: , Roffman, M., and Mendes, D. G.: Fractures of the femur after total hip arthroplasty. Orthopedics, 12: , Scher, M. A.: Fractures of the femoral shaft following total hip replacement. In Proceedings of the South African Orthopaedic Association. J. Bone and Joint Surg., 63-B(3): 472, Schwartz, J. T., Jr.; Mayer, J. G.; and Engh, C. A.: Femoral fracture during non-cemented total hip arthroplasty. J. Bone and Joint Surg., 71 -A: , Sept Scott, R. D.; Turner, R. H.; Leitzes, S. M.; and Aufranc, O. E.: Femoral fractures in conjunction with total hip replacement. J. Bone and Joint Surg., 57-A: , June Serocki, J. H.; Chandler, R. W.; and Dorr, L. D.: Treatment of fractures about hip prostheses with compression plating. J. Arthroplasty, 7: ,1992. VOL. 79-A, NO. 12, DECEMBER 1997

10 1890 D. G. LEWALLEN AND D. J. BERRY 51. Stern, R. E.; Harwin, S. F.; and Kulick, R. G.: Management of ipsilateral femoral shaft fractures following hip arthroplasty. Onhop. Rev., 20: , Stuchin, S. A.: Femoral shaft fracture in porous and press-fit total hip arthroplasty. Onhop. Rev., 19: , Taylor, M. M.; Meyers, M. H.; and Harvey, J. P., Jr.: Intraoperative femur fractures during total hip replacement. Clin. Orthop., 137: , Wang, G.-J.; Miller, T. O.; and Stamp, W. G.: Femoral fracture following hip arthroplasty. Brief note on treatment. J. Bone and Joint Surg., 67-A: , July Whittaker, R. P.; Sotos, L. N.; and Ralston, E. L.: Fractures of the femur about femoral endoprostheses../. Trauma, 14: , Zenni, E. J., Jr.; Pomeroy, D. L.; and Caudle, R. J.: Ogden plate and other fixations for fractures complicating femoral endoprostheses. Clin. Orthop., 231:83-90,1988. THE JOURNAL OF BONE AND JOINT SURGERY

PERIPROSTHETIC FRACTURES FOLLOWING TOTAL HIP ARTHOPLASTY

PERIPROSTHETIC FRACTURES FOLLOWING TOTAL HIP ARTHOPLASTY PERIPROSTHETIC FRACTURES FOLLOWING TOTAL HIP ARTHOPLASTY Jon Minter, DO Arthritis and Total Joint Specialists Atlanta, Georgia ArthritisAndTotalJoint.Com Intra Op Incidence of Periprosthetic Hip Fractures

More information

Outcomes of Surgical Treatment of Periprosthetic Femoral Fractures in Cementless Hip Arthroplasty

Outcomes of Surgical Treatment of Periprosthetic Femoral Fractures in Cementless Hip Arthroplasty ORIGINAL ARTICLE Hip Pelvis 27(3): 146-151, 2015 http://dx.doi.org/10.5371/hp.2015.27.3.146 Print ISSN 2287-3260 Online ISSN 2287-3279 Outcomes of Surgical Treatment of Periprosthetic Femoral Fractures

More information

REVISING THE DEFICIENT PROXIMAL FEMUR

REVISING THE DEFICIENT PROXIMAL FEMUR REVISING THE DEFICIENT PROXIMAL FEMUR by David Mattingly, Boston, MA Joseph McCarthy, Boston, MA Benjamin E. Bierbaum, Boston, MA Hugh P. Chandler, Boston, MA Roderick H. Turner, Boston, MA Hugh U. Cameron,

More information

Surgical Management of Repeated Low-Energy Periprosthetic Femur Fractures - A Case Report -

Surgical Management of Repeated Low-Energy Periprosthetic Femur Fractures - A Case Report - 10.5371/jkhs.2011.23.1.66 Case Report Surgical Management of Repeated Low-Energy Periprosthetic Femur Fractures - Case Report - Taek-Rim Yoon, MD, Kyung-Soon Park, MD, Karupiah Thevarajan, MD, Nam-Young

More information

Peri-prosthetic fractures around the hip

Peri-prosthetic fractures around the hip Vineet Sharma MS *, Aaron G Rosenberg MD** *Consultant, Advanced Hip and Knee Clinic, Chandigarh **Chief of Adult Reconstruction, Rush University Medical Center, 1725 West Harrison Street, Suite 1063 Chicago,

More information

Extensively Porous-coated Stems for Femoral Revision: Reliable Choice for Stem Revision in Paprosky Femoral Type III Defects

Extensively Porous-coated Stems for Femoral Revision: Reliable Choice for Stem Revision in Paprosky Femoral Type III Defects Extensively Porous-coated Stems for Femoral Revision: Reliable Choice for Stem Revision in Paprosky Femoral Type III Defects Lien-Hsiang Chung, MD; Po-Kuei Wu, MD; Cheng-Fong Chen, MD; Wei-Ming Chen, MD;

More information

Treatment of Periprosthetic Femoral Fractures Following Hip Arthroplasty

Treatment of Periprosthetic Femoral Fractures Following Hip Arthroplasty ORIGINAL ARTICLE Hip Pelvis 30(2): 78-85, 2018 http://dx.doi.org/10.5371/hp.2018.30.2.78 Print ISSN 2287-3260 Online ISSN 2287-3279 Treatment of Periprosthetic Femoral Fractures Following Hip Arthroplasty

More information

Clinical and Biomechanical Assessment of the Treatment of Type B Periprosthetic Fractures of the Femur. Fares S Haddad University College Hospital

Clinical and Biomechanical Assessment of the Treatment of Type B Periprosthetic Fractures of the Femur. Fares S Haddad University College Hospital Clinical and Biomechanical Assessment of the Treatment of Type B Periprosthetic Fractures of the Femur Fares S Haddad University College Hospital University College London April 2012 This dissertation

More information

PERIPROSTHETIC FEMUR FRACTURES AFTER THA: Treatment with Revision

PERIPROSTHETIC FEMUR FRACTURES AFTER THA: Treatment with Revision PERIPROSTHETIC FEMUR FRACTURES AFTER THA: Treatment with Revision Daniel J. Berry, MD LZ Gund Professor Department of Orthopedic Surgery Mayo Clinic Rochester, MN Presenter Disclosure Information The author

More information

Use Of A Long Femoral Stem In The Treatment Of Proximal Femoral Fractures: A Report Of Four Cases

Use Of A Long Femoral Stem In The Treatment Of Proximal Femoral Fractures: A Report Of Four Cases ISPUB.COM The Internet Journal of Orthopedic Surgery Volume 5 Number 1 Use Of A Long Femoral Stem In The Treatment Of Proximal Femoral Fractures: A Report Of Four Cases C Yu, V Singh Citation C Yu, V Singh..

More information

Revision hip arthroplasty with S-ROM prosthesis: a study of clinical outcomes and implant stability

Revision hip arthroplasty with S-ROM prosthesis: a study of clinical outcomes and implant stability J Orthopaed Traumatol () 7:1 1 DOI 1.17/s1195--15- ORIGINAL M. El-Deen S. Zahid D.T. Miller A. Nargol R. Logishetty Revision hip arthroplasty with S-ROM prosthesis: a study of clinical outcomes and implant

More information

Fracture of an Acetabular Component Inserted without Cement: A Case Report

Fracture of an Acetabular Component Inserted without Cement: A Case Report Syracuse University SURFACE Biomedical and Chemical Engineering College of Engineering and Computer Science 1997 Fracture of an Acetabular Component Inserted without Cement: A Case Report R T. Trousdale

More information

Revision Total Hip Arthroplasty Using an Extensively Porous Coated Femoral Stem

Revision Total Hip Arthroplasty Using an Extensively Porous Coated Femoral Stem Original Article Clinics in Orthopedic Surgery 2009;1:105-109 doi:10.4055/cios.2009.1.2.105 Revision Total Hip Arthroplasty Using an Extensively Porous Coated Femoral Stem Kyoung Ho Moon, MD, Joon Soon

More information

Unified Classification System (UCS) for peri-prosthetic fractures (PPFx)

Unified Classification System (UCS) for peri-prosthetic fractures (PPFx) Unified Classification System (UCS) for peri-prosthetic fractures (PPFx) Waleed A Abdulwahid Consultant surgeon Medical City, Iraq 6th Emirates International Orthopedic Congress Dubai, UAE May 3-5, 2018

More information

EXTENDED TROCHANTERIC OSTEOTOMY SURGICAL TECHNIQUE FPO EXTENSIVELY COATED FIXATION

EXTENDED TROCHANTERIC OSTEOTOMY SURGICAL TECHNIQUE FPO EXTENSIVELY COATED FIXATION EXTENDED TROCHANTERIC OSTEOTOMY SURGICAL TECHNIQUE FPO EXTENSIVELY COATED FIXATION SINCE 1983 PREOPERATIVE PLANNING EXPLANTATION OPTIONS the cement from inside the cement canal until the bone/ cement bond

More information

KEY CHOICES AND TECHNIQUES IN REVISION THA AND TKA Step-by-Step Decisions

KEY CHOICES AND TECHNIQUES IN REVISION THA AND TKA Step-by-Step Decisions KEY CHOICES AND TECHNIQUES IN REVISION THA AND TKA Step-by-Step Decisions Moderator: Panelists: Daniel J Berry, Mayo Clinic John J Callaghan William L Griffin Thomas P Vail Michael P Bolognesi Presenter

More information

Bone Bangalore

Bone Bangalore Dr Suresh Annamalai MBBS, MRCS(Edn), FRCS( Tr & Orth)(Edn), FEBOT(European Board), Young Hip and Knee Fellowship(Harrogate, UK) Consultant Arthroplasty and Arthroscopic Surgeon Manipal Hospital, Whitefield,

More information

Femoral Fractures in Adolescents: A Comparison of Four Methods of Fixation

Femoral Fractures in Adolescents: A Comparison of Four Methods of Fixation Femoral Fractures in Adolescents: A Comparison of Four Methods of Fixation By Leonhard E. Ramseier, MD, Joseph A. Janicki, MD, Shannon Weir, BSc, and Unni G. Narayanan, MBBS, MSc, FRCSC Investigation performed

More information

Level of Evidence: Prognostic Level II. See Instructions to Authors for a complete description of levels of evidence.

Level of Evidence: Prognostic Level II. See Instructions to Authors for a complete description of levels of evidence. 1215 COPYRIGHT 2006 BY THE JOURNAL OF BONE AND JOINT SURGERY, INCORPORATED Three Hundred and Twenty-one Periprosthetic Femoral Fractures BY HANS LINDAHL, MD, GÖRAN GARELLICK, MD, PHD, HANS REGNÉR, MD,

More information

PRIMARY BIPOLAR ARTHROPLASTY IN TREATMENT OF UNSTABLE INTERTROCHANTERIC FRACTURES IN ELDERLY PATIENTS

PRIMARY BIPOLAR ARTHROPLASTY IN TREATMENT OF UNSTABLE INTERTROCHANTERIC FRACTURES IN ELDERLY PATIENTS PRIMARY BIPOLAR ARTHROPLASTY IN TREATMENT OF UNSTABLE INTERTROCHANTERIC FRACTURES IN ELDERLY PATIENTS *Ibrahim M., Shah Sachin and Kothadia Pradeep Department of Orthopaedics, KBNIMS, Gulbarga, Karnataka,

More information

The Treatment of Pelvic Discontinuity During Acetabular Revision

The Treatment of Pelvic Discontinuity During Acetabular Revision The Journal of Arthroplasty Vol. 20 No. 4 Suppl. 2 2005 The Treatment of Pelvic Discontinuity During Acetabular Revision Scott M. Sporer, MD, MS,*y Michael O Rourke, MD,z and Wayne G. Paprosky, MD, FACS*y

More information

CIRCUMFERENTIAL PROXIMAL FEMORAL ALLOGRAFTS IN REVISION SURGERY ON TOTAL HIP ARTHROPLASTY: CASE REPORTS WITH A MINIMUM FOLLOW-UP OF 20 YEARS

CIRCUMFERENTIAL PROXIMAL FEMORAL ALLOGRAFTS IN REVISION SURGERY ON TOTAL HIP ARTHROPLASTY: CASE REPORTS WITH A MINIMUM FOLLOW-UP OF 20 YEARS CASE REPORT CIRCUMFERENTIAL PROXIMAL FEMORAL ALLOGRAFTS IN REVISION SURGERY ON TOTAL HIP ARTHROPLASTY: CASE REPORTS WITH A MINIMUM FOLLOW-UP OF 20 YEARS Bruno Dutra Roos 1, Milton Valdomiro Roos 2, Antero

More information

Treatment of Peri-Implant Fractures of the Femur

Treatment of Peri-Implant Fractures of the Femur Treatment of Peri-Implant Fractures of the Femur Steven I. Rabin Dreyer Medical Clinic Created January 2006 Revised August 2009 Fractures around Implants Pose Unique Fixation Challenges Number of Implants

More information

Closed reduction and internal fixation of fractures of the shaft of the femur by the Titanium Elastic Nailing System in children.

Closed reduction and internal fixation of fractures of the shaft of the femur by the Titanium Elastic Nailing System in children. ISPUB.COM The Internet Journal of Orthopedic Surgery Volume 17 Number 1 Closed reduction and internal fixation of fractures of the shaft of the femur by the Titanium Elastic Nailing System in children.

More information

Charnley Total Hip Arthroplasty with Use of Improved Cementing Techniques A MINIMUM TWENTY-YEAR FOLLOW-UP STUDY

Charnley Total Hip Arthroplasty with Use of Improved Cementing Techniques A MINIMUM TWENTY-YEAR FOLLOW-UP STUDY 1840 COPYRIGHT 2001 BY THE JOURNAL OF BONE AND JOINT SURGERY, INCORPORATED Charnley Total Hip Arthroplasty with Use of Improved Cementing Techniques A MINIMUM TWENTY-YEAR FOLLOW-UP STUDY BY AIMEE S. KLAPACH,

More information

Use of the Extended Trochanteric Osteotomy in Treating Prosthetic Hip Infection

Use of the Extended Trochanteric Osteotomy in Treating Prosthetic Hip Infection The Journal of Arthroplasty Vol. 24 No. 1 2009 Use of the Extended Trochanteric Osteotomy in Treating Prosthetic Hip Infection Brett R. Levine, MD, MS,* Craig J. Della Valle, MD,y Mark Hamming, BA,y Scott

More information

28 Surgical Technique

28 Surgical Technique Surgical Technique 10 12 14 16 18 20 22 24 28 26 Technique described by James L. Guyton, MD Campbell Clinic Memphis, Tennessee James W. Harkess, MD Campbell Clinic Memphis, Tennessee David G. LaVelle,

More information

The complex problem of the interprosthetic femoral fracture in the elderly patient

The complex problem of the interprosthetic femoral fracture in the elderly patient Acta Orthop. Belg., 2010, 76, 636-643 OriGiNal STUDY The complex problem of the interprosthetic femoral fracture in the elderly patient Yusuf MiCHLA, Lynnette SPALDiNG, James P. HOLLAND, David J. DEEHAN

More information

SURGICAL TECHNIQUE. Protrusio Cage A COMPREHENSIVE ACETABULAR REVISION SYSTEM

SURGICAL TECHNIQUE. Protrusio Cage A COMPREHENSIVE ACETABULAR REVISION SYSTEM SURGICAL TECHNIQUE Protrusio Cage A COMPREHENSIVE ACETABULAR REVISION SYSTEM Important: This essential product information does not include all of the information necessary for selection and use of a device.

More information

Knee Revision. Portfolio

Knee Revision. Portfolio Knee Revision Portfolio I use the DePuy Revision Knee System because of its versatility. With this system I can solve nearly any situation I encounter in the OR. Dr. Thomas Fehring, OrthoCarolina Hip and

More information

IMPORTANT MEDICAL INFORMATION Advanced Orthopaedic Solutions INTRAMEDULLARY NAILS Warnings and Precautions (SINGLE USE ONLY)

IMPORTANT MEDICAL INFORMATION Advanced Orthopaedic Solutions INTRAMEDULLARY NAILS Warnings and Precautions (SINGLE USE ONLY) IMPORTANT MEDICAL INFORMATION Advanced Orthopaedic Solutions INTRAMEDULLARY NAILS Warnings and Precautions (SINGLE USE ONLY) IMPORTANT NOTE Intramedullary nails provide an alternative to open reduction

More information

Impaction femoral allografting and cemented revision for periprosthetic femoral fractures

Impaction femoral allografting and cemented revision for periprosthetic femoral fractures Impaction femoral allografting and cemented revision for periprosthetic femoral fractures E. Tsiridis, A. A. Narvani, F. S. Haddad, J. A. Timperley, G. A. Gie From the Royal Devon and Exeter Hospital,

More information

A 42-year-old patient presenting with femoral

A 42-year-old patient presenting with femoral Kanda et al. Journal of Medical Case Reports 2015, 9:17 JOURNAL OF MEDICAL CASE REPORTS CASE REPORT Open Access A 42-year-old patient presenting with femoral head migration after hemiarthroplasty performed

More information

CASE REPORT PERIPROSTHETIC FRACTURE TREATED WITH A SIMPLE TECHNIQUE: A CASE REPORT

CASE REPORT PERIPROSTHETIC FRACTURE TREATED WITH A SIMPLE TECHNIQUE: A CASE REPORT PERIPROSTHETIC FRACTURE TREATED WITH A SIMPLE TECHNIQUE: A CASE REPORT Bejoy E Jayan 1, Varunjikar M D 2, Dnyaneshwar Kale 3, Suraj S Mahadik 4 HOW TO CITE THIS ARTICLE: Bejoy E Jayan, Varunjikar MD, Dnyaneshwar

More information

DifficultTibialNailRemovalusingtheExtendedTrochantericOsteotomyTechniquePriortoTotalKneeArthroplasty

DifficultTibialNailRemovalusingtheExtendedTrochantericOsteotomyTechniquePriortoTotalKneeArthroplasty : H Orthopedic and Musculoskeletal System Volume 14 Issue 3 Version 1.0 Year 2014 Type: Double Blind Peer Reviewed International Research Journal Publisher: Global Journals Inc. (USA) Online ISSN: 2249-4618

More information

Periprosthetic fractures of the femur: our experience

Periprosthetic fractures of the femur: our experience Acta Biomed 2014; Vol. 85, N. 1: 35-43 Mattioli 1885 Original Article Periprosthetic fractures of the femur: our experience Roberto Valentini, Marcellino Martino, Giovanni De Fabrizio, Giovanni Fancellu

More information

Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis?

Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis? Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis? Diagnosis: Ceramic head fracture In the 1970 s, Boutin implemented ceramic in modern total hip arthroplasty (THA).

More information

Failed Subtrochanteric Fracture How I Decide What to Do?

Failed Subtrochanteric Fracture How I Decide What to Do? Failed Subtrochanteric Fracture How I Decide What to Do? Gerald E. Wozasek Thomas M. Tiefenboeck 5 October 2016, Washington Medical University of Vienna, Department of Trauma Surgery ordination @wozasek.at

More information

Optimum implant geometry

Optimum implant geometry Surgical Technique Optimum implant geometry Extending proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available

More information

Repeated Periprosthethic Femoral Fracture in a Below Knee Amputee with Ipsilateral Cementless Total Hip Arthroplasty - A Case Report -

Repeated Periprosthethic Femoral Fracture in a Below Knee Amputee with Ipsilateral Cementless Total Hip Arthroplasty - A Case Report - CASE REPORT Hip Pelvis 24(4): 322-327, 2012 http://dx.doi.org/10.5371/hp.2012.24.4.322 Print ISSN 2287-3260 Online ISSN 2287-3279 Repeated Periprosthethic Femoral Fracture in a Below Knee Amputee with

More information

Continuing the Tradition. VerSys Heritage Hip System

Continuing the Tradition. VerSys Heritage Hip System Continuing the Tradition VerSys Heritage Hip System Heritage Following the Tradition The low-friction hip prosthesis developed by Sir John Charnley has more than a 20-year history of outstanding results.

More information

J of Evolution of Med and Dent Sci/ eissn , pissn / Vol. 4/ Issue 22/ Mar 16, 2015 Page 3785

J of Evolution of Med and Dent Sci/ eissn , pissn / Vol. 4/ Issue 22/ Mar 16, 2015 Page 3785 COMPARATIVE STUDY OF FRACTURE NECK OF FEMUR TREATED WITH UNIPOLAR AND BIPOLAR HEMIARTHROPLASTY V. Nava Krishna Prasad 1, B. Mohammed Ghouse 2, B. Jaya Chandra Reddy 3, L. Abhishek 4 HOW TO CITE THIS ARTICLE:

More information

Medium- to Long-term Results of Strut Allografts Treating Periprosthetic Bone Defects

Medium- to Long-term Results of Strut Allografts Treating Periprosthetic Bone Defects ORIGINAL ARTICLE http://dx.doi.org/10.5371/hp.2018.30.1.23 Print ISSN 2287-3260 Online ISSN 2287-3279 Medium- to Long-term Results of Strut Allografts Treating Periprosthetic Bone Defects Jun Sung Park,

More information

PLR. Proximal Loading Revision Hip System

PLR. Proximal Loading Revision Hip System PLR Proximal Loading Revision Hip System The PLR splined revision stem is designed to recreate the natural stresses in the revised femur, where proximal bone may be compromised. PLR Hip System Design Considerations

More information

Nonunion of the Femur Treated with Conventional Osteosynthesis Combined with Autogenous and Strut Allogeneic Bone Grafts

Nonunion of the Femur Treated with Conventional Osteosynthesis Combined with Autogenous and Strut Allogeneic Bone Grafts Original Article 268 Nonunion of the Femur Treated with Conventional Osteosynthesis Combined with Autogenous and Strut Allogeneic Bone Grafts Lin-Hsiu Weng, MD; Jun-Wen Wang, MD Background: In this study,

More information

Femoral Revision Algorithm. A practical guide for the use of the CORAIL Hip System in femoral revision surgery

Femoral Revision Algorithm. A practical guide for the use of the CORAIL Hip System in femoral revision surgery Femoral Revision Algorithm A practical guide for the use of the CORAIL Hip System in femoral revision surgery Introduction The principles that govern the mode of prosthetic fixation, implant stability

More information

Management Of Acetabular Deficiency In Total Hip Arthroplasty: A Series Of 15 Cases

Management Of Acetabular Deficiency In Total Hip Arthroplasty: A Series Of 15 Cases ISPUB.COM The Internet Journal of Orthopedic Surgery Volume 21 Number 2 Management Of Acetabular Deficiency In Total Hip Arthroplasty: A Series Of 15 Cases G Khanna, R Sharma, D Singh, T A Chandy Citation

More information

Comparison of two modality of fixation in unstable trochantric fractures in elderly patients

Comparison of two modality of fixation in unstable trochantric fractures in elderly patients Original article Comparison of two modality of fixation in unstable trochantric fractures in elderly patients 1Dr. Vipin Garg, 2 Dr. Anjul Agarwal 1MS Orhtopaedics, Assistant professor, Department of orthopaedics,

More information

Recurrent subluxation or dislocation after surgical

Recurrent subluxation or dislocation after surgical )263( COPYRIGHT 2017 BY THE ARCHIVES OF BONE AND JOINT SURGERY CASE REPORT Persistent Medial Subluxation of the Ulna with Radiotrochlear Articulation Amir R. Kachooei, MD; David Ring, MD, PhD Research

More information

Laura M. Fayad, MD. Associate Professor of Radiology, Orthopaedic Surgery & Oncology The Johns Hopkins University

Laura M. Fayad, MD. Associate Professor of Radiology, Orthopaedic Surgery & Oncology The Johns Hopkins University Society of Pediatric Radiology, May 2013 Laura M. Fayad, MD Associate Professor of Radiology, Orthopaedic Surgery & Oncology The Johns Hopkins University Describes surgical techniques that resect and reconstruct

More information

Long-stem revision prosthesis for salvage of failed fixation of extracapsular proximal femoral fractures

Long-stem revision prosthesis for salvage of failed fixation of extracapsular proximal femoral fractures Acta Orthop. Belg., 2009, 75, 340-345 ORIGINAL STUDY Long-stem revision prosthesis for salvage of failed fixation of extracapsular proximal femoral fractures Rory J. SHARVILL, Nicholas A. FERRAN, Huw G.

More information

Extended Trochanteric Osteotomy Followed by Cemented Impaction Allografting in Revision Hip Arthroplasty

Extended Trochanteric Osteotomy Followed by Cemented Impaction Allografting in Revision Hip Arthroplasty The Journal of Arthroplasty Vol. 28 No. 1 2013 Extended Trochanteric Osteotomy Followed by Cemented Impaction Allografting in Revision Hip Arthroplasty John Charity, MD, MRCS,* Eleftherios Tsiridis, MD,

More information

Tri-Lock Bone Preservation Stem

Tri-Lock Bone Preservation Stem Tri-Lock Bone Preservation Stem Clinical Results of the Tri-lock BPS Femoral Stem at One Year Follow-Up William L. Healy, M.D. Lahey Clinic Medical Center Burlington, Massachusetts Introduction Cementless

More information

Clinical Study Distal Femur Allograft Prosthetic Composite Reconstruction for Short Proximal Femur Segments following Tumor Resection

Clinical Study Distal Femur Allograft Prosthetic Composite Reconstruction for Short Proximal Femur Segments following Tumor Resection Advances in Orthopedics Volume 2013, Article ID 397456, 5 pages http://dx.doi.org/10.1155/2013/397456 Clinical Study Distal Femur Allograft Prosthetic Composite Reconstruction for Short Proximal Femur

More information

Pinit Plate Small Bone Fusion System Bone Plate & Screw System

Pinit Plate Small Bone Fusion System Bone Plate & Screw System Pinit Plate Small Bone Fusion System Bone Plate & Screw System Description The Pinit Plate Small Bone Fusion System consists of 2-hole bone plates made available in three length options and two thickness

More information

Metastatic Disease of the Proximal Femur

Metastatic Disease of the Proximal Femur CASE REPORT Metastatic Disease of the Proximal Femur WI Faisham, M.Med{Ortho)*, W Zulmi, M.S{Ortho)*, B M Biswal, MBBS** 'Department of Orthopaedic, "Department of Oncology and Radiotherapy, School of

More information

EARLY CLINICAL RESULTS OF PRIMARY CEMENTLESS TOTAL KNEE ARTHROPLASTY

EARLY CLINICAL RESULTS OF PRIMARY CEMENTLESS TOTAL KNEE ARTHROPLASTY EARLY CLINICAL RESULTS OF PRIMARY CEMENTLESS TOTAL KNEE ARTHROPLASTY Benkovich V. Perry T., Bunin A., Bilenko V., Unit for Joint Arthroplasty, Soroka Medical Center Ben Gurion University of Negev Beer

More information

The shape and size of femoral components in revision total hip arthroplasty among Chinese patients

The shape and size of femoral components in revision total hip arthroplasty among Chinese patients Journal of Orthopaedic Surgery 2003: 11(1): 53 58 The shape and size of femoral components in revision total hip arthroplasty among Chinese patients KY Chiu, TP Ng, WM Tang Department of Orthopaedic Surgery,

More information

Primary hip arthroplasty through a limited posterior trochanteric osteotomy

Primary hip arthroplasty through a limited posterior trochanteric osteotomy Acta Orthop. Belg., 2005, 71, 548-554 ORIGINAL STUDY Primary hip arthroplasty through a limited posterior trochanteric osteotomy Joaquin SANCHEZ-SOTELO, John GIPPLE, Daniel BERRY, Charles ROWLAND, Robert

More information

Custom Total Femur Spacer and Second-Stage Total Femur Arthroplasty as a Novel Approach to Infection and Periprosthetic Fracture

Custom Total Femur Spacer and Second-Stage Total Femur Arthroplasty as a Novel Approach to Infection and Periprosthetic Fracture The Journal of Arthroplasty Vol. 23 No. 5 2008 Case Report Custom Total Femur Spacer and Second-Stage Total Femur Arthroplasty as a Novel Approach to Infection and Periprosthetic Fracture Seth L. Sherman,

More information

Treatment Alternatives for Pediatric Femoral Fractures

Treatment Alternatives for Pediatric Femoral Fractures Treatment Alternatives for Pediatric Femoral Fractures Gregory A. Schmale, MD Seattle Children's Hospital, USA, gregory.schmale@seattlechildrens.org version 2 I have no conflicts of interest to report

More information

Use of Unlocked Intramedullary Nailing in Winquist Type I and II Femoral Isthmus Fracture

Use of Unlocked Intramedullary Nailing in Winquist Type I and II Femoral Isthmus Fracture Use of Unlocked Intramedullary Nailing in Winquist Type I and II Femoral Isthmus Fracture HT Ling, MBBS (UM), WM Ng, MS Ortho (UM), MK Kwan, MS Ortho (UM), LK Fathi Aizuddeen, MBBS (UM), PCM Tay, MBBS

More information

Clinical and radiological results of the stemmed Mc Minn cup in hip revision surgery

Clinical and radiological results of the stemmed Mc Minn cup in hip revision surgery Acta Orthop. Belg., 2010, 76, 58-62 ORIGINAL STUDY Clinical and radiological results of the stemmed Mc Minn cup in hip revision surgery Pax WILLEMSE, Rene M. CASTELEIN, Paul L. P. A. BOM, Aart VERBURG,

More information

Modular Femoral Tapered Revision Stems in Total Hip Arthroplasty

Modular Femoral Tapered Revision Stems in Total Hip Arthroplasty Joint Implant Surgery & Research Foundation Chagrin Falls, Ohio, USA Modular Femoral Tapered Revision Stems in Total Hip Arthroplasty Benjamin M. Frye, MD, Keith R. Berend, MD, Michael J. Morris, MD, Joanne

More information

RESULTS OF TREATMENT OF PERIPROSTHETIC FEMORAL FRACTURES AFTER TOTAL HIP ARTHROPLASTY

RESULTS OF TREATMENT OF PERIPROSTHETIC FEMORAL FRACTURES AFTER TOTAL HIP ARTHROPLASTY Original articles RESULTS OF TREATMENT OF PERIPROSTHETIC FEMORAL FRACTURES AFTER TOTAL HIP ARTHROPLASTY Martin Korbel, Pavel Šponer, Tomáš Kučera, Egon Procházka, Tomáš Proček Charles University in Prague,

More information

Crossed Steinmann Pin Fixation In Supracondylar Femur Fractures In Adults A Case Series

Crossed Steinmann Pin Fixation In Supracondylar Femur Fractures In Adults A Case Series Article ID: WMC005027 ISSN 2046-1690 Crossed Steinmann Pin Fixation In Supracondylar Femur Fractures In Adults A Case Series Peer review status: No Corresponding Author: Dr. Mohit K Jindal, Senior Resident,

More information

INTERTAN Nails Geared for Stability

INTERTAN Nails Geared for Stability Geared for stability The TRIGEN INTERTAN nail brings advanced TRIGEN nail technology to hip fractures. With a unique integrated, interlocking screw construct, TRIGEN INTERTAN nail provides all the benefits

More information

Revision Total Hip Replacement

Revision Total Hip Replacement Revision Total Hip Replacement Dr. (Prof.) Anil Arora MS (Ortho) DNB (Ortho) Dip SIROT (USA) FAPOA (Korea), FIGOF (Germany), FJOA (Japan) Commonwealth Fellow Joint Replacement (Royal National Orthopaedic

More information

Kudo type-5 total elbow arthroplasty in mutilating rheumatoid arthritis

Kudo type-5 total elbow arthroplasty in mutilating rheumatoid arthritis Upper limb Kudo type-5 total elbow arthroplasty in mutilating rheumatoid arthritis A 5- TO 11-YEAR FOLLOW-UP T. Mori, H. Kudo, K. Iwano, T. Juji From the National Hospital Organization Sagamihara Hospital,

More information

RECOVERY. P r o t r u s i o

RECOVERY. P r o t r u s i o RECOVERY P r o t r u s i o TM C a g e RECOVERY P r o t r u s i o TM C a g e Design Features Revision acetabular surgery is a major challenge facing today s total joint revision surgeon. Failed endo/bi-polars,

More information

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY E C H E L O N P R I M A R Y H I P S Y S T E M P R O D U C T R A T I O N A L E ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY Echelon Primary Total Hip System HIGH OFFSET STANDARD OFFSET Cementless

More information

Total hip arthroplasty (THA) is a

Total hip arthroplasty (THA) is a Review Article Principles of Treatment for Periprosthetic Femoral Shaft Fractures Around Well-fixed Total Hip Arthroplasty Jeffrey Pike, MD Darin Davidson, MD, MHSc Donald Garbuz, MD, MHSc, FRCSC Clive

More information

operative technique Kent Hip

operative technique Kent Hip operative technique Kent Hip The Kent Hip Operative Technique The Kent Hip was developed by Mr Cliff Stossel, FRCS in Maidstone, Kent, UK and first implanted in 1986. It was designed to deal with problems

More information

IJCRI 2011;2(5): Manikam et. al. 21

IJCRI 2011;2(5): Manikam et. al. 21 IJCRI 2011;2(5):21-25. Manikam et. al. 21 CASE REPORT OPEN ACCESS Reversed tibial locking plates in management of traumatic ipsilateral periprosthetic fractures of the distal femur and proximal tibia after

More information

Arcos Modular Femoral Revision System

Arcos Modular Femoral Revision System Arcos Modular Femoral Revision System Arcos System Simplify the Complex The Arcos Modular Femoral Revision System meets the demands of complex hip revision surgery by offering surgeons and OR staff the

More information

CASE REPORT. Bone transport utilizing the PRECICE Intramedullary Nail for an infected nonunion in the distal femur

CASE REPORT. Bone transport utilizing the PRECICE Intramedullary Nail for an infected nonunion in the distal femur PRODUCTS CASE REPORT Bone transport utilizing the PRECICE Intramedullary Nail for an infected nonunion in the distal femur Robert D. Fitch, M.D. Duke University Health System 1 1 CONDITION Infected nonunion

More information

Elbow Fractures ORIF VS Arthroplasty

Elbow Fractures ORIF VS Arthroplasty Elbow Fractures ORIF VS Arthroplasty Oke Anakwenze, M.D. Olympus Orthopedics No disclosures Disclosures Distal humerus fractures 0.5-0.7% of all fractures 30% of all elbow fractures Bimodal etiology Young

More information

Case Report Massive Femoral Osteolysis Secondary to Loosening of a Cemented Roughened Long Stem: A Case Report

Case Report Massive Femoral Osteolysis Secondary to Loosening of a Cemented Roughened Long Stem: A Case Report Case Reports in Orthopedics, Article ID 840267, 4 pages http://dx.doi.org/10.1155/2014/840267 Case Report Massive Femoral Osteolysis Secondary to Loosening of a Cemented Roughened Long Stem: A Case Report

More information

PERIPROSTHETIC FRACTURE FOLLOWING TOTAL KNEE ARTHROPLASTY: REVIEW ARTICLE

PERIPROSTHETIC FRACTURE FOLLOWING TOTAL KNEE ARTHROPLASTY: REVIEW ARTICLE PERIPROSTHETIC FRACTURE FOLLOWING TOTAL KNEE ARTHROPLASTY: REVIEW ARTICLE Dr. Mohan Krishna Dhunju*, Prof. Dr. Lu Hou Gen and Prof. Dr. Liu Jun Department of Orthopaedics Surgery Unit-1, Clinical Medical

More information

This publication is not intended for distribution in the USA.

This publication is not intended for distribution in the USA. This publication is not intended for distribution in the USA. Extraction of a CORAIL Stem Surgical Technique Introduction Given the excellent long-term results of the CORAIL stem, 1,2,3 its extraction

More information

Technique Guide Small Bone Fusion System

Technique Guide Small Bone Fusion System Technique Guide Small Bone Fusion System The Pinit Plate Small Bone Fusion System is a super low profile, modular bone plate and screw system designed to stabilize a bunionectomy with a medial to lateral

More information

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique Enhanced Stability Constrained Liners Design Rationale Surgical Technique The Pinnacle Acetabular Cup System was designed to maximize the number of options available to the surgeon, and provide those options

More information

WHAT IS THE BEST BONE FIXATION TYPE? 2/11/2011

WHAT IS THE BEST BONE FIXATION TYPE? 2/11/2011 WHAT IS THE BEST BONE FIXATION TYPE? 2/11/2011 A Comparison of cement vs. bone ingrowth. Thomas P. Gross, M.D. At 2 years of follow-up cemented and uncemented femoral resurfacing is equivalent. Femoral

More information

Restoration Modular. Revision Hip System Surgical Protocol

Restoration Modular. Revision Hip System Surgical Protocol Orthopaedics Restoration Modular Revision Hip System Surgical Protocol Restoration Modular Cone Body/Conical Distal Stem Femoral Components Using the Restoration Modular Instrument System Restoration Modular

More information

Orthopaedic Surgery Hip

Orthopaedic Surgery Hip Transverse Subtrochanteric Shortening Osteotomy in Total Hip Arthroplasty for Severe Hip Developmental Dysplasia Myung-Sik Park Professor, Department of Orthopaedic Surgery, Chonbuk National University

More information

Complications of Total Knee Arthroplasty

Complications of Total Knee Arthroplasty Progress in Clinical Medicine Complications of Total Knee Arthroplasty JMAJ 44(5): 235 240, 2001 Shinichi YOSHIYA*, Masahiro KUROSAKA** and Ryosuke KURODA*** *Director, Department of Orthopaedic Surgery,

More information

Page Proof 1 of 5. Fig. E1-A The INTERTAN nail was short or long.

Page Proof 1 of 5. Fig. E1-A The INTERTAN nail was short or long. Page 1 of 5 Fig. E1-A The INTERTAN nail was short or long. Fig. E1-B The sliding hip screw comes in different lengths, and is used with or without a trochanteric stabilizing plate. Page Proof 1 of 5 Page

More information

Femoral Osteolysis Around the Unrevised Stem During Isolated Acetabular Revision

Femoral Osteolysis Around the Unrevised Stem During Isolated Acetabular Revision Clin Orthop Relat Res (2009) 467:1501 1506 DOI 10.1007/s11999-008-0499-6 ORIGINAL ARTICLE Femoral Osteolysis Around the Unrevised Stem During Isolated Acetabular Revision Byung-Woo Min MD, Kwang-Soon Song

More information

Cotyloplasty in Cementless Total Hip Arthroplasty for an Insufficient Acetabulum

Cotyloplasty in Cementless Total Hip Arthroplasty for an Insufficient Acetabulum Original Article Clinics in Orthopedic Surgery 2010;2:148-153 doi:10.4055/cios.2010.2.3.148 Cotyloplasty in Cementless Total Hip Arthroplasty for an Insufficient Acetabulum Yong Lae Kim, MD, Kwang Woo

More information

Salvage of failed dynamic hip screw fixation of intertrochanteric fractures

Salvage of failed dynamic hip screw fixation of intertrochanteric fractures Injury, Int. J. Care Injured (2005) xxx, xxx xxx 1 www.elsevier.com/locate/injury 2 3 4 5 6 7 8 8 9 10 11 12 13 14 15 Salvage of failed dynamic hip screw fixation of intertrochanteric s G.Z. Said, O. Farouk

More information

Fractures of the tibia shaft treated with locked intramedullary nail Retrospective clinical and radiographic assesment

Fractures of the tibia shaft treated with locked intramedullary nail Retrospective clinical and radiographic assesment ARS Medica Tomitana - 2013; 4(75): 197-201 DOI: 10.2478/arsm-2013-0035 Șerban Al., Botnaru V., Turcu R., Obadă B., Anderlik St. Fractures of the tibia shaft treated with locked intramedullary nail Retrospective

More information

PediNail Pediatric Femoral Nail

PediNail Pediatric Femoral Nail PediNail Pediatric Femoral Nail Surgical Technique Table of Contents Indications...3 Patient Positioning...3 Approach...4 Reaming...5 Nail Placement...6 Proximal Interlocking...7 Distal Interlocking...8

More information

7/23/2018 DESCRIBING THE FRACTURE. Pattern Open vs closed Location BASIC PRINCIPLES OF FRACTURE MANAGEMENT. Anjan R. Shah MD July 21, 2018.

7/23/2018 DESCRIBING THE FRACTURE. Pattern Open vs closed Location BASIC PRINCIPLES OF FRACTURE MANAGEMENT. Anjan R. Shah MD July 21, 2018. BASIC PRINCIPLES OF FRACTURE MANAGEMENT Anjan R. Shah MD July 21, 2018 DESCRIBING THE FRACTURE Pattern Open vs closed Location POLL OPEN HOW WOULD YOU DESCRIBE THIS FRACTURE PATTERN? 1 Spiral 2 Transverse

More information

EMPERION Modular Hip System Surgical Technique

EMPERION Modular Hip System Surgical Technique Surgical Technique Introduction The EMPERION Modular Hip System is a versatile system that can be used for primary and revision hip surgeries. Using modular proximal bodies, this system addresses the proximal

More information

DISCLOSURE FNFX ORIF OR ARTHROPLASTY? 11/21/2016 FEMORAL NECK FRACTURES: ORIF OR ARTHROPLASTY? ROYALTIES DEPUY, BIOMET

DISCLOSURE FNFX ORIF OR ARTHROPLASTY? 11/21/2016 FEMORAL NECK FRACTURES: ORIF OR ARTHROPLASTY? ROYALTIES DEPUY, BIOMET FEMORAL NECK FRACTURES: ORIF OR ARTHROPLASTY? GEORGE HAIDUKEWYCH, MD ORLANDO, FLORIDA DISCLOSURE ROYALTIES DEPUY, BIOMET CONSULTING DEPUY, SYNTHES, BIOMET, RESPONSIVE ORTHOPEDICS STOCK OWNERSHIP ORTHOPEDIATRICS

More information

Treatment of periprosthetic femoral fractures after femoral revision using a long stem

Treatment of periprosthetic femoral fractures after femoral revision using a long stem Kim et al. BMC Musculoskeletal Disorders (2015) 16:113 DOI 10.1186/s12891-015-0565-7 RESEARCH ARTICLE Open Access Treatment of periprosthetic femoral fractures after femoral revision using a long Youngwoo

More information

76 F: Plays tennis, lives independently, told she has weak bone

76 F: Plays tennis, lives independently, told she has weak bone Femoral Neck Fractures In the ELDERLY What to do, when and why Frank Liporace, MD Chairman & VP, Dept of Orthopaedics Chief of Trauma & Adult Reconstruction Jersey City Medical Center / RWJ Barnabas Health

More information

Optimum implant geometry

Optimum implant geometry Design Rationale Optimum implant geometry Extending proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available

More information

Uncemented Total Hip Arthroplasty With Subtrochanteric Derotational Osteotomy for Severe Femoral Anteversion

Uncemented Total Hip Arthroplasty With Subtrochanteric Derotational Osteotomy for Severe Femoral Anteversion The Journal of Arthroplasty Vol. 14 No. 6 1999 Uncemented Total Hip Arthroplasty With Subtrochanteric Derotational Osteotomy for Severe Femoral Anteversion Hamid G. Zadeh, FRCS(Orth), Jia Hua, MD, PhD,

More information