Equivalence of Nasal and Oronasal Masks during Initial CPAP Titration for Obstructive Sleep Apnea Syndrome
|
|
- Evan Stokes
- 5 years ago
- Views:
Transcription
1 NASAL VERSUS ORO-NASAL MASKS DURING CPAP TITRATION FOR OSA DOI: /SLEEP.1134 Equivalence of Nasal and Oronasal s during Initial CPAP Titration for Obstructive Apnea Syndrome Ming Teo, MBBS 2 ; Terence Amis, PhD 1,3 ; Sharon Lee, RN 1,3 ; Karina Falland, BAppSc 2 ; Stephen Lambert, MApplSc 2 ; John Wheatley, PhD Ludwig Engel Centre for Respiratory Research, Westmead Millennium Institute, 2 Department of Respiratory and Medicine, and 3 University of Sydney at Westmead Hospital, Westmead, NSW, Australia Study Objective: Continuous positive airway pressure (CPAP) titration studies are commonly performed using a nasal mask but some patients may prefer a full-face or oronasal mask. There is little evidence regarding the equivalence of different mask interfaces used to initiate treatment. We hypothesized that oronasal breathing when using an oronasal mask increases upper airway collapsibility and that a higher pressure may be required to maintain airway patency. We also assessed patient preferences for the 2 mask interfaces. Design: Prospective, randomized, cross-over design with 2 consecutive CPAP titration nights. Setting: Accredited laboratory in a university hospital. Patients or Participants: Twenty-four treatment-naïve subjects with obstructive sleep apnea syndrome and respiratory disturbance index of greater than 15 events per hour. Interventions: CPAP titration was performed using an auto-titrating machine with randomization to a nasal or oronasal mask, followed by a second titration night using the alternate mask style. Measurements and Results: There was no significant difference in the mean pressures determined between nasal and oronasal masks, although 43% of subjects had nasal-to-oronasal mask-pressure differences of 2 cm O or more. Residual respiratory events, arousals, and measured leak were all greater with the oronasal mask. Seventy-nine percent of subjects preferred the nasal mask. Conclusions: Patients with obstructive sleep apnea syndrome can generally switch between nasal and oronasal masks without changing machine pressure, although there are individual differences that may be clinically significant. Measured leak is greater with the oronasal mask. Most patients with obstructive sleep apnea syndrome prefer a nasal mask as the interface for initiation of CPAP. Clinical Trial Registration: Australian New Zealand Clinical Trials Registry (ANZCTR). ACTRN: ACTRN URL: ZCTR.org.au/ACTRN aspx Keywords: Obstructive sleep apnea, continuous positive airway pressure, nasal, oronasal, mask leak Citation: Teo M; Amis T; Lee S; Falland K; Lambert S; Wheatley J. Equivalence of nasal and oronasal masks during initial CPAP titration for obstructive sleep apnea syndrome. SLEEP 211;34(7): INTRODUCTION The most commonly prescribed therapy for symptomatic obstructive sleep apnea syndrome (OSAS) is continuous positive airway pressure (CPAP). A number of studies have now demonstrated that properly adjusted CPAP therapy is effective at preventing snoring, upper airway obstruction, and oxygen desaturation, as well as reversing symptoms of OSAS. 1 Traditionally, CPAP therapy is initiated at a fixed pressure following a titration procedure that may be undertaken manually overnight in a sleep-laboratory setting or, alternatively, by an automatictitrating CPAP machine in the home or laboratory setting. 2 Two of the main variables that are key to the initiation of effective CPAP therapy are the mask interface chosen and the final determined CPAP that is prescribed. Although there are now well-documented practice parameters developed by the American Academy of Medicine for the initiation of CPAP therapy, 1 there is little evidence available regarding the equivalence of different mask interfaces that Submitted for publication November, 21 Submitted in final revised form January, 211 Accepted for publication February, 211 Address correspondence to: John R. Wheatley, MD, PhD, Westmead Hospital, Department of Respiratory Medicine, PO Box 533, Wentworthville, NSW, Australia; Tel: (61) ; Fax: (61) ; john_wheatley@wmi.usyd.edu.au may be used to initiate treatment. Currently, there are multiple different styles of mask interfaces available for treatment, and it is likely that patient acceptance of and adherence with CPAP therapy may be optimized by choosing the mask interface that provides the most effective and acceptable therapy regimen on an individual-patient basis. Most mask interfaces fall into 2 broad categories, either a nasal-only interface, which provides CPAP exclusively via the nasal route, or an oronasal interface, which delivers CPAP to both the nasal and oral routes. A Cochrane review of CPAP-delivery interfaces for OSAS therapy concluded that the optimal interface for CPAP delivery remained unclear due to the limited number of studies available that compare interface types. 3 In particular, there were few data available to guide the clinician as to whether the pressure required for CPAP delivered by an oronasal mask is equivalent to that required with a nasal-only mask. When an oronasal mask is used as a CPAP interface, the CPAP is applied to the nasal route and can also be applied to the oral route, simply by opening the mouth. It has previously been demonstrated that mouth opening increases upper airway collapsibility. 4,5 Therefore, we hypothesized that, because the upper airway may be more collapsible when breathing via the oronasal route, use of an oronasal mask would require a higher pressure to maintain upper airway patency, as compared with the nasal-only mask. To test this hypothesis, we randomly assigned patients to 2 separate CPAP-titration nights, which were identical apart from using an oronasal mask or a nasal mask, to SLEEP, Vol. 34, No. 7, Nasal and Oro-Nasal s during Initial CPAP for OSA Teo et al
2 Table 1 Characteristics of the 24 study participants Parameter Results Age, y 51.3 ± 13.3 Male sex, no. 18 BMI, kg/m ± 9.4 Neck circumference, cm 41.7 ± 4.8 RDI, events/h 47. ± 15.2 AI, events/h 35.9 ± 15.8 Min O 2 sat, % 79.3 ± 14.2 Data are presented as mean ± SD. BMI, body mass index; RDI, respiratory disturbance index; AI, arousal index; Min O 2 sat, minimum oxygen saturation. clarify whether the CPAP interface type can influence the final determined CPAP. METHODS We studied 24 subjects who were referred to a sleep laboratory in a university hospital for CPAP titration. Patients had OSAS of at least moderate severity (respiratory disturbance index > 15 events/h) on a baseline polysomnogram and had no previous experience with CPAP. Subjects were excluded for previous oronasal operations, history of clinically severe nasal or sinus disease, complex sleep disordered breathing, significant comorbid respiratory or cardiac disease, and orofacial problems precluding the use of a nasal or oronasal mask. Informed consent was obtained, and the protocol was approved by the Sydney West Area Health Service Human Research Ethics Committee. Protocol Baseline data collection included measurement of anthropometric data and the Epworth iness Scale. Nasal resistance was measured using posterior rhinomanometry while the subjects were awake in the seated posture. 6 Each subject underwent 2 consecutive, attended, full-polysomnography, CPAP-titration studies, with randomization (computer-generated first-night mask choice) to either a nasal (Resmed Micro Mirage, Sydney, Australia) or an oronasal (Resmed Quattro Mirage) mask on the first night, with the alternate mask style used on the second night. A chinstrap (Seatec, Sydney, Australia) was always used in conjunction with the nasal mask to reduce the occurrence of mouth leak. Heated humidification was used on both study nights. technicians fitted and adjusted the interface as per the manufacturer s recommendations and provided patient support during the night as required. Subjects were monitored with standard polysomnography, 7 including direct measurement of pressure in the mask, together with the pressure, flow, and leak output signals from the CPAP device, with all signals recorded on a computerized monitoring system (Compumedics Profusion 3, Abbotsford, Australia). CPAP was automatically titrated with the same Autoset S8 II Spirit CPAP device (Resmed) on both nights, and sleep technicians did not manually titrate pressure. On the morning following each CPAP study, the patient s subjective perception of sleep quality, mask comfort and fit, mouth dryness, and overall satisfaction with each mask style was assessed using a 1-point visual analogue scale ( = poorest, 1 = best). At the conclusion of both studies, they were asked to nominate their preferred mask style. Data Analysis Studies were scored according to standard guidelines 8,9 for sleep staging, arousals, and respiratory events. All polysomnograms were scored by 1 sleep technician who was blinded to the interface used, with calculation of the respiratory disturbance index, arousal index, sleep efficiency, total sleep time, wake after sleep onset time, and time spent in each sleep stage. The summary data from the CPAP device were also downloaded to obtain the 95 th percentile pressure level and 95 th percentile leak, as computed by the device. Because both mask interfaces and the CPAP device were compatible Resmed products, the leak data downloaded from the device only reflected the unintentional leak (mask cushion seal leak or mouth leak [nasal mask]) over and above the intentional mask leak (related to individual mask dead-space washout). All scored polysomnograms were also reviewed by a single sleep physician who was blinded to the interface used and the summary data from the CPAP device. Concealment of interface style was maintained by de-identifying each subject s study data prior to scoring and reporting, with only 1 researcher (MT) aware of which study interface was used. The physician-determined pressure (PDP) was the final prescribed CPAP level for each study based on the minimum pressure required to abolish all obstructive events, oxygen desaturations, and snoring, with pressures above this level assessed for improvement in the nasal pressure flow profile, and the PDP that minimized flow limitation prescribed, provided that mask leak was not increased. Group data were expressed as mean values (± SD). Variables were compared between nasal and oronasal mask nights using paired t-test analysis. A P value of <.5 was regarded as statistically significant. RESULTS The study-group characteristics and baseline diagnostic polysomnography data are presented in Table 1. The subjects were generally middle-aged obese men and had severe obstructive sleep apnea syndrome. Two patients had awake nasal resistances that were elevated above the upper limit of the reference range (3.3 cm O L -1 sec -1 ) at 6.5 and 8.9 cm O L -1 sec -1. Eleven subjects used a nasal mask on the first night, whereas the remaining 13 subjects used an oronasal mask on the first night. The PDP when using the nasal mask was 11.4 ± 1.9 cm O, which was not different from that determined when using the oronasal mask (11.8 ± 2.4 cm O; P =.46). The 95 th percentile pressure (determined by the CPAP device) when using the nasal mask was 12.2 ± 2.2 cm O, which also did not differ from that determined when using the oronasal mask (11.9 ± 1.4 cm O; P =.48). When PDP values were compared with device-determined pressures, there was no difference in group mean pressure for the oronasal mask (P =.73). However, for the nasal mask, the device-determined pressure (12.2 ± 2.2 cm O) was significantly higher than the PDP (11.4 ± 1.9 cm O; P =.1), with a mean difference of.8 cm O. For the PDP SLEEP, Vol. 34, No. 7, Nasal and Oro-Nasal s during Initial CPAP for OSA Teo et al
3 Number of Patients PDP (cm O) Figure 1 A frequency histogram for the PDP (physician-determined pressure) for patients when they used the oronasal (ON) mask minus the PDP using the nasal (N) mask ( PDP). Note that 11 of 24 subjects had a PDP of ± 2 cm O, and 1 subject had a difference of +7 cm O. (The dashed line refers to the mean PDP =.4 cm O; dotted lines, ± 2 SD) Table 2 Titration outcomes by mask style Nasal Oronasal P Value RDI, events/h 5.3 ± ± efficiency (%) 82.3 ± ± AI, events/h 13.3 ± ± th percentile leak, L/min 11.2 ± ± 9.9 <.1 Data are presented as mean ± SD. RDI, respiratory disturbance index; AI, arousal index. ferences between the 2 mask styles for the quantities of stages 1 and 2 non-rapid eye movement sleep, rapid eye movement sleep, and supine sleep. Patients rated nasal masks as better fitting (nasal = 7.5 ± 1.9 arbitrary units [au], oronasal = 5.4 ± 2.6 au; P <.1), and more comfortable (nasal = 6.3 ± 2.1 au, oronasal = 4.4 ± 2.6 au; P =.2). Overall satisfaction was also greater with the nasal mask (6.7 ± 2.1 au), compared with the oronasal mask (4.5 ± 2.6 au; P <.1). Perceived sleep quality was not different when using a nasal mask (6.2 ± 2.2 au), compared with an oronasal mask (5.2 ± 2.2 au; P =.13). Figure 3 shows the differences in visual analogue scale scores between the 2 nights. Seven pameasurements, we calculated the difference between the nasal and oronasal mask values for each individual subject (Figure 1). When the distribution of pressure differences was examined, only 1 patient s pressure difference was more than 2 standard deviations from the mean. The majority of patients had pressure differences of less than 2 cm O. However, 11 subjects (or 46%) had differences of 2 cm O or greater. The 2 subjects with elevated awake nasal resistances both had pressure differences of less than 2 cm O. We compared the polysomnography titration outcomes by mask style for the 2 nights (Table 2). The residual respiratory disturbance index and the arousal index were higher when using the oronasal mask. In addition, the 95 th percentile leak doubled with the oronasal mask. There was also a trend toward a lower sleep efficiency when using an oronasal mask; however, this difference did not reach statistical significance. Differences in sleep architecture were measured between the 2 titration nights (Figure 2). When patients used the oronasal mask, there was a significantly reduced amount of total sleep time (oronasal = 319 ± 76 min, nasal = 366 ± 65 min; P =.1) and time spent in slow wave sleep (oronasal = 76 ± 39 min, nasal = 94 ± 36 min; P <.1). There were no significant dif- ON - N (minutes) Figure 2 Durations of sleep variables, based on the results of 2 nights of polysomnography. Data represent the durations on the nights with continuous positive airway pressure titration using an oronasal (ON) mask minus the durations of these same variables from the nights on which a nasal (N) mask was used. TST refers to total sleep time; WASO, wake after sleep onset; SWS, slow wave sleep; REM, rapid eye movement. Open circles refer to the mean difference; bars, ± 1 SD; P <.5. ON - N VAS (arbitrary units) TST WASO Stage One Quality Fit Stage Two SWS REM Supine Figure 3 Scores from the visual analogue scales (VAS) for patients undergoing continuous positive airway pressure titration with an oronasal (ON) mask minus their scores from the night they used a nasal (N) mask. Open circles represent mean differences; bars, ± 1 SD; P <.5. Comfort Oronasal mask better Nasal mask better Satisfaction SLEEP, Vol. 34, No. 7, Nasal and Oro-Nasal s during Initial CPAP for OSA Teo et al
4 tients reported dry mouth when using a nasal mask, compared with 16 subjects when using an oronasal mask. Overall, 19 patients nominated the nasal mask as their preferred interface, 4 patients chose the oronasal mask, and 1 patient was undecided. DISCUSSION In a group of patients with newly diagnosed OSAS commencing CPAP therapy, there was no significant difference in either the PDP or machine-determined pressures for the prescribed therapeutic CPAP levels, as measured via CPAP titration using a nasal versus an oronasal mask. However, CPAP titration with an oronasal mask, as compared with a nasal mask, was characterized by increased mask leak, increased residual respiratory disturbance and arousal indexes, decreased amount of slow wave sleep, and decreased amount of total sleep time on the titration night. From a subjective viewpoint, patients expressed a preference for the nasal mask, particularly in relation to mask fit and mask comfort. This study is the first to directly compare the pressures determined using different mask interfaces on separate CPAP-titration nights in a group of patients who did not have any prior CPAP experience. In contrast, the 5 patients studied by Prosise et al. 1 had previously used nasal CPAP for periods ranging from 6 months to 3 years and did not have a separate CPAP titration performed using an oronasal mask. They concluded that an effective level of CPAP applied with a nasal mask was similarly effective, compared with an oronasal mask, but were unable to conclude that the optimal level of CPAP had been delivered by the oronasal mask. In our group, the level of CPAP titrated differed between the 2 interfaces by 2 cm O or more in 11 subjects, suggesting that there are interindividual differences that may be clinically significant. We did not study nightto-night variability in titrated pressure using the same interface, but there is some evidence from home-based automatic CPAP titration that the determined pressure does not demonstrate significant variance over a 1-week period. 11 Our data suggested that differences in body position or elevated nasal resistances were unlikely to account for any differences in the titrated pressure between the 2 test nights. Interestingly, there are no American Academy of Medicine practice parameter 1 recommendations that provide guidance as to what would be the minimum difference in titrated pressure that is likely to be of clinical significance. Meurice et al. 12 studied the effect of treatment pressure set with 2 different titration methods, either to eliminate flow limitation (mean pressure 1.4 ± 2.6 cm O) or to eliminate apnea, hypopnea, and snoring (mean pressure 8.9 ± 2.6 cm O), with a resultant mean treatment pressure difference of 1.5 cm O. They reported a longer nightly duration of CPAP use in the group treated for flow limitation (7.3 h vs 6. h), which, if maintained over a longer period, could potentially translate into meaningful clinical outcomes. In the present study, there was only 1 patient whose determined pressure difference was more than 2 standard deviations above the mean (7 cm O higher) when using an oronasal mask, compared with a nasal mask. This particular patient also had a much higher 95 th percentile leak when using the oronasal mask (44 L/min) compared with the nasal mask (18L/min). The higher oronasal mask-determined pressure in this patient may therefore reflect titration difficulties encountered by the auto- matic CPAP device in the presence of a large leak. It has also been demonstrated that automatic CPAP devices may have a tendency to pressure overshoot if there are increased arousals and fragmented sleep, 13 which was the case with the oronasal mask. An alternative explanation for the high pressure difference may relate to a bimodal distribution of pressure differences, with a small group of patients always requiring higher pressures with an oronasal mask. The role of the mask style was studied by Mortimore et al. 14 in 2 patients with newly diagnosed OSAS following a 1-night nasal-mask CPAP-titration study. Patients were then randomly assigned to CPAP with a nasal or oronasal mask at the same fixed pressure for 4 weeks each. This study demonstrated that compliance was greater with the nasal mask CPAP, with a corresponding larger reduction in the Epworth iness Scale score, and the authors attributed this finding to improved overall mask comfort. However, the possible impact of suboptimal pressure titration for the oronasal mask, leading to less effective therapy and reduced compliance, was not able to be addressed by this study. There are data to suggest that both mask style and CPAP pressure are important determinants of ongoing CPAP compliance. 12,14 In our study, use of an oronasal mask for CPAP titration was associated with less consolidated sleep, with decreased total sleep time and reduced slow wave sleep. Similarly, Prosise et al. 1 found significantly less stage 2 non-rapid eye movement sleep when using an oronasal mask, as well as a trend toward a decreased total sleep time, increased wakefulness, and increased amount of stage 1 non-rapid eye movement sleep. These differences in sleep architecture seen with use of an oronasal mask during initial titration may not necessarily be the case following a period of acclimatization and treatment at a fixed pressure of CPAP with this interface. However, a study by Drake et al. 15 found that improvement in sleep efficiency from the diagnostic night to the titration night was the best predictor of subsequent CPAP compliance. Thus, it is plausible that a better first-night effect (as occurred with the nasal mask night in our study) will carry over to better patient acceptance and adherence to longterm therapy. There was a clear patient preference for use of a nasal mask following a 1-night trial of each interface in our study. Similarly, Mortimore et al. 14 reported that, in a group of 2 patients commencing CPAP, 19 patients preferred a nasal mask over an oronasal mask, following a 4-week trial of each mask interface. The patients in our study reported increased mouth dryness when using an oronasal mask, as compared with a nasal mask, most likely due to the minimization of mouth leak by use of a chin-strap with the nasal mask, whereas significant mouth breathing may have persisted with an oronasal mask. Overall, our data clearly demonstrated that the leak is doubled by the use of an oronasal mask, suggesting that it is inherently more difficult to achieve a good seal with these interfaces, which may complicate the delivery of therapy in some cases. Strengths of this study include the use of an automatic titrating CPAP device to objectively provide an algorithm-based titration and minimize pressure-titration variability between the 2 nights, such as may have occurred with a manual titration. Adequacy of determined pressure was reviewed in a blinded fashion by an experienced sleep physician, and all CPAP titra- SLEEP, Vol. 34, No. 7, Nasal and Oro-Nasal s during Initial CPAP for OSA Teo et al
5 tions were judged to have provided an adequate level of CPAP using the automatic device. Another strength of the study was the quantitative measure of leak provided by the automatic CPAP machine, which has not been assessed in previous studies comparing interfaces, all of which have relied on subjective assessment of leak. 14,16,17 Limitations of this study include the relatively small sample size, which may have hampered our ability to detect either small differences in mean determined pressure or any bimodal distribution of pressure differences. However, it remains unclear whether a small significant pressure difference of less than 1 cm O, if demonstrated in a much larger sample size, would have any clinically significant meaning. In addition, we have only used 1 brand of automatic-titrating CPAP machine with the correctly sized manufacturer s mask, which may limit the generalizability of results to other mask styles and CPAP machines. Finally, our results may not be applicable to a situation in which a nasal mask is used without a properly fitted chin strap. We were unable to assess the degree of mouth opening or the separate contributions of oral and nasal airflows when patients used an oronasal mask. This would have been of particular interest, as the degree of mouth opening may have altered upper airway anatomy and collapsibility, 4,5 which may have explained some of the variability in determined pressure between nasal and oronasal masks. It has previously been demonstrated that mouth opening increases collapsibility of the upper airway, 4 possibly by posterior-inferior mandibular displacement, resulting in narrowing of the oropharyngeal cross-sectional area. This mandibular displacement may also adversely impact the length-tension relationships of the upper airway dilator muscles, thereby reducing their contractile force. 5 In addition, softpalate apposition with the tongue may be lost with the use of an oronasal mask, further reducing the patency of the oropharynx. Thus, the degree of mouth opening and associated posterior displacement of the tongue base may substantially increase the CPAP required to maintain airway patency, and it is possible that the individual configuration of upper airway anatomy when using the oronasal mask may explain some of the variability in pressure between the different interface styles. In conclusion, for the initial titration of CPAP in patients with OSAS, nasal and oronasal masks are interchangeable in terms of the final determined pressure, although there are individual differences that may be clinically significant. In addition, patients prefer the use of nasal masks, which fit better, are more comfortable, leak less, result in longer and better quality sleep, and are generally cheaper. Thus, our study supports the use of a nasal mask as the initial interface of choice in titrating CPAP for patients with OSAS, and we speculate that this may translate into improved longer-term adherence to CPAP treatment with better clinical outcomes. However, this would require confirmation by future studies comparing outcomes for the use of oronasal versus nasal masks in longer-term CPAP therapy. ACKNOWLEDGMENTS The authors thank Resmed, Sydney, NSW, Australia, for supplying nasal and oronasal masks for this study, as well as the au- tomatic titrating continuous positive airway pressure machine. All work was performed at Westmead Hospital. DISCLOSURE STATEMENT Automatic titrating CPAP machine, nasal and oronasal masks were provided courtesy of ResMed Australia. Dr. Wheatley has participated in clinical trial research projects funded by Actelion, Apnex Medical, Boehringer Ingelheim, and GlaxoSmith- Kline The other authors have indicated no financial conflicts of interest. REFERENCES 1. Kushida CA, Littner MR, Hirshkowitz M, et al. Practice parameters for the use of continuous and bilevel positive airway pressure devices to treat adult patients with sleep-related breathing disorders. 26;29: Littner M, Hirshkowitz M, Davila D, et al. Practice parameters for the use of auto-titrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome. 22;25: Chai CL, Pathinathan A, Smith B. Continuous positive airway pressure delivery interfaces for obstructive sleep apnoea. Cochrane Database Syst Rev 26;4:CD Meurice JC, Marc I, Carrier G, Sériès F. Effects of mouth opening on upper airway collapsibility in normal sleeping subjects. Am J Respir Crit Care Med 1996;153: Kuna ST, Remmers JE. Neural and anatomic factors related to upper airway occlusion during sleep. Med Clin North Am 1985;69: Wheatley JR, Amis TC, Engel LA. Nasal and oral airway pressure-flow relationships. J Appl Physiol 1991;71: Kushida CA, Littner MR, Morgenthaler T, et al. Parameters for the indications for polysomnography and related procedures: an update for ;28: The Report of an American Academy of Medicine Task Force. -related breathing disorders in adults: recommendations for syndrome definition and measurement techniques in clinical research. 1999; 22: Rechtschaffen A, Kales A, eds. A Manual of Standardized Terminology, Techniques, and Scoring System for Stages of Human Subjects. US Department of Health, Education, and Welfare Public Health Service NIH/NIND; Prosise GL, Berry RB. Oral-nasal continuous positive airway pressure as a treatment for obstructive sleep apnea. Chest 1994;16: Sériès F, Plante J, Lacasse Y. Reliability of home CPAP titration with different automatic CPAP devices. Resp Res 28;9: Meurice JC, Paquereau J, Denjean A, Patte F, Sériès F. Influence of correction of flow limitation on continuous positive airway pressure efficiency in sleep apnoea/hypopnoea syndrome. Eur Respir J 1998;11: Marrone O, Insalaco G, Bonsignore MR, Romano S, Salvaggio A, Bonsignore G. structure correlates of continuous positive airway pressure variations during application of an autotitrating continuous positive airway pressure machine in patients with obstructive sleep apnea syndrome. Chest 22;121: Mortimore IL, Whittle AT, Douglas NJ. Comparison of nose and face mask CPAP therapy for sleep apnoea. Thorax 1998;53: Drake CL, Day R, Hudgel D, Stefadu Y, Parks M, Syron ML, Roth T. during titration predicts continuous positive airway pressure compliance. 23;26: Wilson GN, Piper AJ, Norman M, et al. Nasal versus full face mask for non-invasive ventilation in chronic respiratory failure. Eur Respir J 24;23: Criner GJ, Travaline JM, Brennan KJ, Kreimer DT. Efficacy of a new full face mask for non-invasive positive pressure ventilation. Chest 1994;16: SLEEP, Vol. 34, No. 7, Nasal and Oro-Nasal s during Initial CPAP for OSA Teo et al
Positive Airway Pressure and Oral Devices for the Treatment of Obstructive Sleep Apnea
Positive Airway Pressure and Oral Devices for the Treatment of Obstructive Sleep Apnea Policy Number: Original Effective Date: MM.01.009 11/01/2009 Line(s) of Business: Current Effective Date: HMO; PPO
More informationPatients commonly arouse from sleep and experience awake states.
Sensitive to Sleep Patients commonly arouse from sleep and experience awake states. PATIENTS are intolerant of the delivered pressure and can have difficulty returning to sleep. To aid the transition back
More informationPositive Airway Pressure and Oral Devices for the Treatment of Obstructive Sleep Apnea
Positive Airway Pressure and Oral Devices for the Treatment of Obstructive Sleep Apnea Policy Number: Original Effective Date: MM.01.009 11/01/2009 Line(s) of Business: Current Effective Date: HMO; PPO;
More informationManagement of OSA. saurabh maji
Management of OSA saurabh maji INTRODUCTION Obstructive sleep apnea is a major public health problem Prevalence of OSAS in INDIA is 2.4% to 4.96% in men and 1% to 2 % in women In the rest of the world
More informationPEDIATRIC PAP TITRATION PROTOCOL
PURPOSE In order to provide the highest quality care for our patients, our sleep disorders facility adheres to the AASM Standards of Accreditation. The accompanying policy and procedure on pediatric titrations
More informationPositive Airway Pressure and Oral Devices for the Treatment of Obstructive Sleep Apnea
Positive Airway Pressure and Oral Devices for the Treatment of Obstructive Sleep Apnea Policy Number: Original Effective Date: MM.01.009 11/01/2009 Line(s) of Business: Current Effective Date: HMO; PPO;
More informationPrecision Sleep Medicine
Precision Sleep Medicine Picking Winners Improves Outcomes and Avoids Side-Effects North American Dental Sleep Medicine Conference February 17-18, 2017 Clearwater Beach, FL John E. Remmers, MD Conflict
More informationResScan Report Interpretation Guide. FOR CLINICAL USE ONLY V1.0 June, 2011
ResScan Report Interpretation Guide FOR CLINICAL USE ONLY V1.0 June, 2011 ResMed Software Support Hours 5:30 AM to 5:30 PM (Pacific Time) Monday Friday Phone +1 (800) 424-0737, Option 6 Email TechSupportUSA@resmed.com
More informationGoals Session Putting it all Together
Goals Session Putting it all Together Adherence to therapy Case presentations Treatment issues Charles Atwood, MD, FCCP, FAASM University of Pittsburgh Disclosures Advisory - Carecore National; Philips;
More information(To be filled by the treating physician)
CERTIFICATE OF MEDICAL NECESSITY TO BE ISSUED TO CGHS BENEFICIAREIS BEING PRESCRIBED BILEVEL CONTINUOUS POSITIVE AIRWAY PRESSURE (BI-LEVEL CPAP) / BI-LEVEL VENTILATORY SUPPORT SYSTEM Certification Type
More informationHow to choose the right mask under long term nocturnal NIV
How to choose the right mask under long term nocturnal NIV Jean Christian Borel j.borel@agiradom.com 1 AGIRàdom. Associa-on 38- Meylan 2 Univ Grenoble Alpes, HP2, 38000 Grenoble France 3 CRIUCPQ, Université
More informationThe International Palestinian Congress in Sleep Medicine
The International Palestinian Congress in Sleep Medicine Temporomandibular Disorders and Sleep Apnea 26 and 27 October, 2017 Notre Dame Hotel, Jerusalem Using PAP Downloads to Manage Sleep Apnea Patients
More informationContinuous positive airway pressure titration for obstructive sleep apnoea: automatic versus manual titration
< Supplementary tables are published online only. To view these files please visit the journal online (http://throax.bmj. com). 1 University of Western Australia, School of Medicine and Pharmacology, Respiratory
More informationRole of different nocturnal monitorings in the evaluation of CPAP titration by autocpap devices
Respiratory Medicine (2005) 99, 313 320 Role of different nocturnal monitorings in the evaluation of CPAP titration by autocpap devices Oreste Marrone, Giuseppe Insalaco, Adriana Salvaggio, Giovanni Bonsignore
More informationEffect of two types of mandibular advancement splints on snoring and obstructive sleep apnoea
European Journal of Orthodontics 20 (1998) 293 297 1998 European Orthodontic Society Effect of two types of mandibular advancement splints on snoring and obstructive sleep apnoea J. Lamont*, D. R. Baldwin**,
More informationPhilip L. Smith, MD; Christopher P. O Donnell, PhD; Lawrence Allan, BS; and Alan R. Schwartz, MD
A Physiologic Comparison of Nasal and Oral Positive Airway Pressure* Philip L. Smith, MD; Christopher P. O Donnell, PhD; Lawrence Allan, BS; and Alan R. Schwartz, MD Study objectives: The effectiveness
More informationPolysomnography (PSG) (Sleep Studies), Sleep Center
Policy Number: 1036 Policy History Approve Date: 07/09/2015 Effective Date: 07/09/2015 Preauthorization All Plans Benefit plans vary in coverage and some plans may not provide coverage for certain service(s)
More informationSplit Night Protocols for Adult Patients - Updated July 2012
Split Night Protocols for Adult Patients - Updated July 2012 SUMMARY: Sleep technologists are team members who work under the direction of a physician practicing sleep disorders medicine. Sleep technologists
More informationComparative Efficacy of Two Expiratory Pressure Reduction Systems in the Treatment of Obstructive Sleep Apnea
Sleep Diagnosis and Therapy 2009 V4 N1 Wolfe et al Comparative Efficacy of Two Expiratory Pressure Reduction Systems in the Treatment of Obstructive Sleep Apnea Lisa Wolfe, MD, 1 Clifford A. Massie, PhD,
More informationCoding for Sleep Disorders Jennifer Rose V. Molano, MD
Practice Coding for Sleep Disorders Jennifer Rose V. Molano, MD Accurate coding is an important function of neurologic practice. This section of is part of an ongoing series that presents helpful coding
More informationNON-INVASIVE VENTILATION MADE RIDICULOUSLY SIMPLE
NON-INVASIVE VENTILATION MADE RIDICULOUSLY SIMPLE Jennifer Newitt, MD 3 rd year Pulmonary/Critical Care Fellow Mentor: Patrick Strollo Jr, MD Myth or Fact?!? Myth or Fact?!? Treatment for Obstructive
More informationJoel Reiter*, Bashar Zleik, Mihaela Bazalakova, Pankaj Mehta, Robert Joseph Thomas
Joel Reiter*, Bashar Zleik, Mihaela Bazalakova, Pankaj Mehta, Robert Joseph Thomas Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA *ומעבדת השינה הדסה עין כרם, ירושלים חיפפ ירושלים,
More informationPersistence of Upper-Airway Symptoms During CPAP Compromises Adherence at 1 Year
Persistence of Upper-Airway Symptoms During CPAP Compromises Adherence at 1 Year Hanna-Riikka Kreivi MD PhD, Paula Maasilta MD PhD, and Adel Bachour MD PhD BACKGROUND: The most common adverse effects of
More informationCPAP titration by an auto-cpap device based on snoring detection: a clinical trial and economic considerations
Eur Respir J 199; : 759 7 DOI:.113/09031936.9.0759 Printed in UK - all rights reserved Copyright ERS Journals Ltd 199 European Respiratory Journal ISSN 0903-1936 CPAP titration by an auto-cpap device based
More informationRESEARCH PACKET DENTAL SLEEP MEDICINE
RESEARCH PACKET DENTAL SLEEP MEDICINE American Academy of Dental Sleep Medicine Dental Sleep Medicine Research Packet Page 1 Table of Contents Research: Oral Appliance Therapy vs. Continuous Positive Airway
More informationEmerging Nursing Roles in Collaborative Management of Sleep Disordered Breathing and Obstructive Sleep Apnoea
Emerging Nursing Roles in Collaborative Management of Sleep Disordered Breathing and Obstructive Sleep Apnoea Sigma Theta Tau International 28th International Nursing Research Congress 27-31 July 2017
More informationBrian Palmer, D.D.S, Kansas City, Missouri, USA. April, 2001
Brian Palmer, D.D.S, Kansas City, Missouri, USA A1 April, 2001 Disclaimer The information in this presentation is for basic information only and is not to be construed as a diagnosis or treatment for any
More informationPositive Pressure Therapy
Positive Pressure Therapy Positive Pressure Therapy...2 What is Sleep Apnea?....2 Positive Pressure Machines..................................................... 4 Types..................................................................................
More informationDisclosures. Michael Gunnuscio RPSGT, Bob Chase RRT, Umakanth Khatwa MD
Disclosures Michael Gunnuscio and Umakanth Khatwa have no financial relationships to disclose. Robert Chase works full time with North Atlantic Medical. Copyright 2014 Boston Children s Hospital 1 CPAP
More informationA new beginning in therapy for women
A new beginning in therapy for women OSA in women Tailored solutions for Her AutoSet for Her algorithm ResMed.com Women and OSA OSA has traditionally been considered to be a male disease. However, recent
More informationClinical Technologies
Clinical Technologies Stylish on the Outside. Smart on the Inside. UNIQUE CLINICAL TECHNOLOGIES AVAILABLE WITH F&P ICON ThermoSmart Technology for more humidity and comfort Auto-adjusting algorithm for
More informationRespiratory Event Detection by a Positive Airway Pressure Device
RESPIRATORY EVENT DETECTION BY A POSITIVE AIRWAY PRESSURE DEVICE http://dx.doi.org/.5665/sleep.1696 Respiratory Event Detection by a Positive Airway Pressure Device Richard B. Berry, MD 1 ; Clete A. Kushida,
More informationHelping You to Breathe Better, Sleep Easy & Live Well
Helping You to Breathe Better, Sleep Easy & Live Well Your Guide to CPAP Therapy info@cansleep.ca Vancouver Island Lower Mainland Fraser Valley Sleep Apnea & Symptoms Obstructive Sleep Apnea (OSA) occurs
More informationAuto Servo Ventilation Indications, Basics of Algorithm, and Titration
Auto Servo Ventilation Indications, Basics of Algorithm, and Titration 1 ASV Learning Objectives Understand the indications for Auto Servo Ventilation Differentiate obstructive versus central hypopneas
More informationComparison of two in-laboratory titration methods to determine evective pressure levels in patients with obstructive sleep apnoea
Thorax 2000;55:741 745 741 Centre de Recherche, Hôpital Laval, Institut Universitaire de Cardiologie et de Pneumologie de l Université Laval, Sainte-Foy, Québec G1V 4G5, Canada M P Bureau F Sériès Correspondence
More informationQuestions: What tests are available to diagnose sleep disordered breathing? How do you calculate overall AHI vs obstructive AHI?
Pediatric Obstructive Sleep Apnea Case Study : Margaret-Ann Carno PhD, CPNP, D,ABSM for the Sleep Education for Pulmonary Fellows and Practitioners, SRN ATS Committee April 2014. Facilitator s guide Part
More informationWhat is SDB? Obstructive sleep apnea-hypopnea syndrome (OSAHS)
Have a Good Sleep? Estimated 70 million Americans have clinically significant sleep problems Chronic insomnias report decreased quality of life, memory and attention problems, decreased physical health
More informationIndex. sleep.theclinics.com. Note: Page numbers of article titles are in boldface type.
Index Note: Page numbers of article titles are in boldface type. A Acquired central hypoventilation syndrome, NPPV in children with, 475 Acute cardiogenic pulmonary edema, PAP therapy in, 394 395 Adaptive
More informationClinical Trials in OSA
24th ANNUAL ADVANCES IN SLEEP APNEA AND SNORING February 16-17, 2018 Grand Hyatt on Union Square San Francisco, California Clinical Trials in OSA Samuel T. Kuna, MD Department of Medicine Center for Sleep
More informationCritical Review Form Diagnostic Test
Critical Review Form Diagnostic Test Diagnosis and Initial Management of Obstructive Sleep Apnea without Polysomnography A Randomized Validation Study Annals of Internal Medicine 2007; 146: 157-166 Objectives:
More informationBiPAPS/TVAPSCPAPASV???? Lori Davis, B.Sc., R.C.P.T.(P), RPSGT
BiPAPS/TVAPSCPAPASV???? Lori Davis, B.Sc., R.C.P.T.(P), RPSGT Modes Continuous Positive Airway Pressure (CPAP): One set pressure which is the same on inspiration and expiration Auto-PAP (APAP) - Provides
More informationClinical Guidelines for the Manual Titration of Positive Airway Pressure in Patients with Obstructive Sleep Apnea
Special Article Clinical Guidelines for the Manual Titration of Positive Airway Pressure in Patients with Obstructive Sleep Apnea Positive Airway Pressure Titration Task Force of the American Academy of
More informationNasal versus full face mask for noninvasive ventilation in chronic respiratory failure.
Eur Respir J 2004; 23: 605 609 DOI: 10.1183/09031936.04.00051604 Printed in UK all rights reserved Copyright #ERS Journals Ltd 2004 European Respiratory Journal ISSN 0903-1936 Nasal versus full face mask
More informationO bstructive sleep apnoea (OSA) is a common condition
226 SLEEP DISORDERED BREATHING Comparison of three ways to determine and deliver pressure during nasal CPAP therapy for obstructive sleep apnoea S D West, D R Jones, J R Stradling... See end of article
More information(HST) (95806, G0398, G0399)
95800 Sleep study, unattended, simultaneous recording of, heart rate, oxygen saturation, respiratory analysis (e.g. by airflow or peripheral arterial tone), and sleep time 95801 Sleep study, unattended,
More informationPrediction of sleep-disordered breathing by unattended overnight oximetry
J. Sleep Res. (1999) 8, 51 55 Prediction of sleep-disordered breathing by unattended overnight oximetry L. G. OLSON, A. AMBROGETTI ands. G. GYULAY Discipline of Medicine, University of Newcastle and Sleep
More informationOSA and COPD: What happens when the two OVERLAP?
2011 ISRC Seminar 1 COPD OSA OSA and COPD: What happens when the two OVERLAP? Overlap Syndrome 1 OSA and COPD: What happens when the two OVERLAP? ResMed 10 JAN Global leaders in sleep and respiratory medicine
More information11/13/2017. Jeremy Tabak MD, FAASM Medical Director Baptist Hospital Sleep Lab Medical Director Baptist Sleep Lab at Galloway
Jeremy Tabak MD, FAASM Medical Director Baptist Hospital Sleep Lab Medical Director Baptist Sleep Lab at Galloway HypnoLaus study: OSA effect on mortality US Preventive Services Task Force recommendations
More informationTolerance of Positive Airway Pressure following Site-Specific Surgery of Upper Airway
34 The Open Sleep Journal, 2008, 1, 34-39 Open Access Tolerance of Positive Airway Pressure following Site-Specific Surgery of Upper Airway Ho-Sheng Lin *,#,1,2, Roger Toma #,2, Cara Glavin 2, Mark Toma
More informationTOPIC: Continuing Coverage of CPAP Machines and Supplies for the Treatment of Obstructive Sleep Apnea
These documents are not used to determine benefits or reimbursement. Please reference the appropriate certificate or contract for benefit information. BLUE CROSS BLUE SHIELD of MI MEDICAL POLICY Enterprise:
More informationAverage volume-assured pressure support
Focused review Average volume-assured pressure support Abdurahim Aloud MD Abstract Average volume-assured pressure support (AVAPS) is a relatively new mode of noninvasive positive pressure ventilation
More informationEnclosed on Page 5 is an authorization form to release your health information.
Monitor Medical, Inc. "The CPAP Co." Ph: (877) 569-9436 Fax: (888) 773-2854 www.monitormedical.com Dear Medicare Beneficiary: Thank you for selecting Monitor Medical, Inc. to provide you with all of your
More informationInternational Journal of Scientific & Engineering Research Volume 9, Issue 1, January ISSN
International Journal of Scientific & Engineering Research Volume 9, Issue 1, January-2018 342 The difference of sleep quality between 2-channel ambulatory monitor and diagnostic polysomnography Tengchin
More informationChronic NIV in heart failure patients: ASV, NIV and CPAP
Chronic NIV in heart failure patients: ASV, NIV and CPAP João C. Winck, Marta Drummond, Miguel Gonçalves and Tiago Pinto Sleep disordered breathing (SDB), including OSA and central sleep apnoea (CSA),
More informationOral Appliances and their Clinical Applications
Oral Appliances and their Clinical Applications Peter Cistulli MBBS, PhD, MBA, FRACP Professor of Respiratory Medicine & Head of Discipline of Sleep Medicine University of Sydney Director, Centre for Sleep
More informationThe Familial Occurrence of Obstructive Sleep Apnoea Syndrome (OSAS)
Global Journal of Respiratory Care, 2014, 1, 17-21 17 The Familial Occurrence of Obstructive Sleep Apnoea Syndrome (OSAS) Piotr Bielicki, Tadeusz Przybylowski, Ryszarda Chazan * Department of Internal
More informationQUESTIONS FOR DELIBERATION
New England Comparative Effectiveness Public Advisory Council Public Meeting Hartford, Connecticut Diagnosis and Treatment of Obstructive Sleep Apnea in Adults December 6, 2012 UPDATED: November 28, 2012
More informationContinuous Positive Airway Pressure (CPAP)
Patient Information Continuous Positive Airway Pressure (CPAP) Author: Pulmonary physiology, sleep and ventilation Produced and designed by the Communications Team Issue date July 2017 Expiry date July
More informationObstructive sleep apnea (OSA) is characterized by. Quality of Life in Patients with Obstructive Sleep Apnea*
Quality of Life in Patients with Obstructive Sleep Apnea* Effect of Nasal Continuous Positive Airway Pressure A Prospective Study Carolyn D Ambrosio, MD; Teri Bowman, MD; and Vahid Mohsenin, MD Background:
More informationOral Appliances and their Clinical Indications in OSA
Oral Appliances and their Clinical Indications in OSA Disclosures Andrew Chan, MB BS, PhD, FRACP, FCCP Staff Specialist, Department of Respiratory and Sleep Medicine, Royal North Shore Hospital, University
More informationChristopher D. Turnbull 1,2, Daniel J. Bratton 3, Sonya E. Craig 1, Malcolm Kohler 3, John R. Stradling 1,2. Original Article
Original Article In patients with minimally symptomatic OSA can baseline characteristics and early patterns of CPAP usage predict those who are likely to be longer-term users of CPAP Christopher D. Turnbull
More informationIndex. sleep.theclinics.com. Note: Page numbers of article titles are in boldface type.
Note: Page numbers of article titles are in boldface type. A Accidents. See Motor vehicle accidents. Acetazolamide, in OSA therapy, 531 Acetylcholinesterase inhibitors, in OSA therapy, 532 533 Acromegaly,
More informationSedative Use During Continuous Positive Airway Pressure Titration Improves Subsequent Compliance. A Randomized, Double-Blind, Placebo-Controlled Trial
CHEST Sedative Use During Continuous Positive Airway Pressure Titration Improves Subsequent Compliance A Randomized, Double-Blind, Placebo-Controlled Trial Christopher J. Lettieri, MD, FCCP; Jacob F. Collen,
More informationTired of being tired?
Tired of being tired? Narval CC MRD ResMed.com/Narval Sleepiness and snoring are possible symptoms of sleep apnea. Did you know that one in every four adults has some form of sleep disordered-breathing
More informationTreatment of central sleep apnoea in congestive heart failure with nasal ventilation
Thorax 1998;53(Suppl 3):S41 46 S41 Centre for Respiratory Failure and Sleep Disorders and Royal Prince Alfred Hospital, Sydney, NSW, Australia David Read Laboratory, Department of Medicine, University
More informationCLINICIAN INFORMATION
CLINICIAN INFORMATION CLINICIAN INFORMATION RHINOMED Rhinomed is a medical device technology company with a patented nasal technology platform that seeks to radically improve the way you breathe, sleep,
More informationNational Sleep Disorders Research Plan
Research Plan Home Foreword Preface Introduction Executive Summary Contents Contact Us National Sleep Disorders Research Plan Return to Table of Contents SECTION 5 - SLEEP DISORDERS SLEEP-DISORDERED BREATHING
More informationSleep Diordered Breathing (Part 1)
Sleep Diordered Breathing (Part 1) History (for more topics & presentations, visit ) Obstructive sleep apnea - first described by Charles Dickens in 1836 in Papers of the Pickwick Club, Dickens depicted
More informationKey words: adenotonsillectomy; arousal; rapid eye movement sleep; sleep apnea
Sleep Characteristics Following Adenotonsillectomy in Children With Obstructive Sleep Apnea Syndrome* Asher Tal, MD; Amir Bar, MD; Alberto Leiberman, MD; and Ariel Tarasiuk, PhD Objective: To compare the
More informationPractice Parameters for the Use of Portable Monitoring Devices in the Investigation of Suspected Obstructive Sleep Apnea in Adults
PRACTICE PARAMETERS Practice Parameters for the Use of Portable Monitoring Devices in the Investigation of Suspected Obstructive Sleep Apnea in Adults A joint project sponsored by the American Academy
More informationInspire Therapy for Sleep Apnea
Inspire Therapy for Sleep Apnea Patient Guide Giving You the FREEDOM TO SLEEP Like Everyone Else Take Comfort. Inspire therapy can help. Inspire therapy is a breakthrough implantable treatment option for
More informationA 74-year-old man with severe ischemic cardiomyopathy and atrial fibrillation
1 A 74-year-old man with severe ischemic cardiomyopathy and atrial fibrillation The following 3 minute polysomnogram (PSG) tracing was recorded in a 74-year-old man with severe ischemic cardiomyopathy
More informationBTS sleep Course. Module 10 Therapies I: Mechanical Intervention Devices (Prepared by Debby Nicoll and Debbie Smith)
BTS sleep Course Module 10 Therapies I: Mechanical Intervention Devices (Prepared by Debby Nicoll and Debbie Smith) S1: Overview of OSA Definition History Prevalence Pathophysiology Causes Consequences
More informationOBSTRUCTIVE SLEEP APNEA and WORK Treatment Update
OBSTRUCTIVE SLEEP APNEA and WORK Treatment Update David Claman, MD Professor of Medicine Director, UCSF Sleep Disorders Center 415-885-7886 Disclosures: None Chronic Sleep Deprivation (0 v 4 v 6 v 8 hrs)
More informationDr Alireza Yarahmadi and Dr Arvind Perathur Mercy Medical Center - Winter Retreat Des Moines February 2012
Dr Alireza Yarahmadi and Dr Arvind Perathur Mercy Medical Center - Winter Retreat Des Moines February 2012 Why screen of OSA prior to surgery? What factors increase the risk? When due to anticipate problems?
More informationHelping You to Breathe Better, Sleep Easy & Live Well
Helping You to Breathe Better, Sleep Easy & Live Well Your Guide to CPAP Therapy info@cansleep.ca Lower Mainland Vancouver Island Fraser Valley Sleep Apnea & Symptoms Obstructive Sleep Apnea (OSA) occurs
More informationOSA - Obstructive sleep apnoea What you need to know if you think you might have OSA
OSA - Obstructive sleep apnoea What you need to know if you think you might have OSA Obstructive sleep apnoea, or OSA, is a breathing problem that happens when you sleep. It can affect anyone men, women
More informationSleep and the Heart Reversing the Effects of Sleep Apnea to Better Manage Heart Disease
1 Sleep and the Heart Reversing the Effects of Sleep Apnea to Better Manage Heart Disease Rami Khayat, MD Professor of Internal Medicine Director, OSU Sleep Heart Program Medical Director, Department of
More informationComfort and pressure profiles of two autoadjustable positive airway pressure devices: a technical report
Respiratory Medicine (23) 97, 93 98 Comfort and pressure profiles of two autoadjustable positive airway pressure devices: a technical report Katrien B. Hertegonne, Pascal M. Proot, Romain A. Pauwels, Dirk
More informationCase 1. Level of difficulty: 2/5
Case 1 Level of difficulty: 2/5 Summary Settings in the ventilator BULBAR ALS Ventilation 24h/24, Good tolerance PaO2 82; PaCO2 : 42, ph=7,42 (under ventilation) Mode: S/T Main parameters : Pressure Support
More informationSleep Apnea in Women: How Is It Different?
Sleep Apnea in Women: How Is It Different? Grace Pien, MD, MSCE Division of Pulmonary and Critical Care Department of Medicine Johns Hopkins School of Medicine 16 February 2018 Outline Prevalence Clinical
More informationHigh Flow Nasal Cannula in Children During Sleep. Brian McGinley M.D. Associate Professor of Pediatrics University of Utah
High Flow Nasal Cannula in Children During Sleep Brian McGinley M.D. Associate Professor of Pediatrics University of Utah Disclosures Conflicts of Interest: None Will discuss a product that is commercially
More informationOriginal Effective Date: Subject: Expiratory Positive Airway Pressure (EPAP) for Obstructive Sleep Apnea 10/30/13
Subject: Expiratory Positive Airway Pressure (EPAP) for Obstructive Sleep Apnea Guidance Number: MCG-145 Revision Date(s): Original Effective Date: 10/30/13 Medical Coverage Guidance Approval Date: 10/30/13
More informationSleep Disordered Breathing
Sleep Disordered Breathing SDB SDB Is an Umbrella Term for Many Disorders characterized by a lack of drive to breathe Results n repetitive pauses in breathing with no effort Occurs for a minimum of 10
More informationThe pathophysiology of obstructive sleep apnea (OSA) is
Scientific investigations A Pilot Evaluation of a Nasal Expiratory Resistance Device for the Treatment of Obstructive Sleep Apnea Ian M. Colrain, Ph.D. 1,2 ; Stephen Brooks, M.D. 3 ; Jed Black, M.D. 3
More informationComparison of three ways to determine and deliver pressure during nasal CPAP therapy for Obstructive Sleep Apnoea
Thorax Online First, published on October 27, 2005 as 10.1136/thx.2005.046300 Comparison of three ways to determine and deliver pressure during nasal CPAP therapy for Obstructive Sleep Apnoea Sophie D
More informationEquivalence of Autoadjusted and Constant Continuous Positive Airway Pressure in Home Treatment of Sleep Apnea*
Original Research SLEEP MEDICINE Equivalence of Autoadjusted and Constant Continuous Positive Airway Pressure in Home Treatment of Sleep Apnea* Yvonne Nussbaumer, MD; Konrad E. Bloch, MD, FCCP; Therese
More informationMandibular Advancement Device vs CPAP in the Treatment of Obstructive Sleep Apnea: Are they Equally Effective in Short Term Health Outcomes?
NoSnores Mandibular Advancement Device (mouthguard) for Snoring & Sleep Apnea CLINICAL REFERENCES J Clin Sleep Med. 2013 Sep;9(9):971-2. doi: 10.5664/jcsm.3008. Mandibular Advancement Device vs CPAP in
More informationObstructive sleep apnoea How to identify?
Obstructive sleep apnoea How to identify? Walter McNicholas MD Newman Professor in Medicine, St. Vincent s University Hospital, University College Dublin, Ireland. Potential conflict of interest None Obstructive
More informationDuring the therapeutic titration of nasal continuous
Cardiogenic Oscillations on the Airflow Signal During Continuous Positive Airway Pressure as a Marker of Central Apnea* Indu Ayappa, PhD; Robert G. Norman, MS, RRT; and David M. Rapoport, MD, FCCP Therapeutic
More informationDiagnostic Accuracy of the Multivariable Apnea Prediction (MAP) Index as a Screening Tool for Obstructive Sleep Apnea
Original Article Diagnostic Accuracy of the Multivariable Apnea Prediction (MAP) Index as a Screening Tool for Obstructive Sleep Apnea Ahmad Khajeh-Mehrizi 1,2 and Omid Aminian 1 1. Occupational Sleep
More informationDECLARATION OF CONFLICT OF INTEREST
DECLARATION OF CONFLICT OF INTEREST Obstructive sleep apnoea How to identify? Walter McNicholas MD Newman Professor in Medicine, St. Vincent s University Hospital, University College Dublin, Ireland. Potential
More informationVPAP Auto Positive Airway Pressure Device Data Management Guide English
VA Auto ositive Airway ressure Device Data Management Guide English The following table shows where data from the VA Auto flow generator can be viewed. Data displayed in ResScan can be downloaded via:
More informationUPDATES IN SLEEP APNEA:
UPDATES IN SLEEP APNEA: CPAP,CPAP COMPLIANCE, & ALTERNATIVES MICHELLE ZETOONY, DO, FCCP, FACOI BOARD CERTIFIED PULMONARY, CRITICAL CARE, SLEEP & INTERNAL MEDICINE CLEARWATER, FL DISCLOSURE I have no conflicts
More informationA Sleep Laboratory Evaluation of an Automatic Positive Airway Pressure System for Treatment of Obstructive Sleep Apnea
A Sleep Laboratory Evaluation of an Automatic Positive Airway Pressure System for Treatment of Obstructive Sleep Apnea Khosrow Behbehani, 1 Fu-Chung Yen, 1 Edgar A. Lucas, 2 and John R. Burk 2 (1) Joint
More informationMECHANISMS OF UPPER AIRWAY HYPOTONIA DURING REM SLEEP
MECHANISMS OF UPPER AIRWAY HYPOTONIA DURING REM SLEEP http://dx.doi.org/10.5665/sleep.3498 Physiological Mechanisms of Upper Airway Hypotonia during REM Sleep David G. McSharry, MD 1,2 ; Julian P. Saboisky,
More informationObstructive Sleep Apnea Syndrome. Common sleep disorder causes high blood pressure and heart attacks
Obstructive Sleep Apnea Syndrome Common sleep disorder causes high blood pressure and heart attacks Message: Sleep apnea is very common. It is estimated that 158 million people worldwide suffer from sleep
More informationDiabetes & Obstructive Sleep Apnoea risk. Jaynie Pateraki MSc RGN
Diabetes & Obstructive Sleep Apnoea risk Jaynie Pateraki MSc RGN Non-REM - REM - Both - Unrelated - Common disorders of Sleep Sleep Walking Night terrors Periodic leg movements Sleep automatism Nightmares
More informationObstructive sleep apnea (OSA) is the periodic reduction
Obstructive Sleep Apnea and Oxygen Therapy: A Systematic Review of the Literature and Meta-Analysis 1 Department of Anesthesiology, Toronto Western Hospital, University Health Network, University of Toronto,
More information