A computational fluid dynamics simulation study of coronary blood flow affected by graft placement

Size: px
Start display at page:

Download "A computational fluid dynamics simulation study of coronary blood flow affected by graft placement"

Transcription

1 Interactive CardioVascular and Thoracic Surgery 19 (2014) doi: /icvts/ivu034 Advance Access publication 22 April 2014 ORIGINAL ARTICLE ADULTCARDIAC A computational fluid dynamics simulation study of coronary blood flow affected by graft placement Jason V. Lassaline a and Byung C. Moon b, * a b Ryerson University, Toronto, Canada Southlake Regional Health Centre, Newmarket, Canada * Corresponding author. Division of Cardiac Surgery, Southlake Regional Health Centre, 625 Davis Drive, Newmarket, ON, Canada L3Y 2R2. Tel: ; fax: ; bmoon.cardiac@gmail.com (B.C. Moon). Received 1 October 2013; received in revised form 19 January 2014; accepted 29 January 2014 Abstract OBJECTIVES: To determine the effect of graft placement and orientation on flow rates through a partially obstructed coronary artery. METHODS: A numerical, parametric study of blood flow in the human coronary artery was conducted using computational fluid dynamics simulation. A cylindrical approximation of the coronary artery with varying degrees of stenosis, with and without a bypass graft, was modelled to determine trends in volumetric flow rates. Steady and transient simulations were conducted for geometric variations of percentage of blockage, length and shape of stenosis, graft position relative to the coronary blockage and graft orientation. Accurate simulations were performed using a non-newtonian fluid model and pressure-driven viscous flow. RESULTS: Simulations demonstrate, as expected, that total outlet flow rates of grafted arteries are consistently improved for upstream stenosis varying between 0 and 90% blockage. Grafts angled towards the artery provided increased total outflow. However, flow rates in the coronary artery upstream of the graft are substantially reduced in comparison with the non-grafted configuration due to competing flows. For some configurations (reduced blockage, graft placed close to long grafts), flow rates in the graft are below that of the flow rate through the stenosis. In general, a graft angled more towards the artery increased flow rates upstream of the graft. CONCLUSIONS: Placement and orientation of a graft may adversely affect upstream flow, with the degree of effect dependent on geometric factors of downstream position and graft angle. Keywords: Coronary stenosis Computational fluid dynamics Anastomosis INTRODUCTION Recent fluid dynamic research on vascular anastomosis has focused on determining the relationship between haemodynamics and graft failures. Haemodynamic forces, in particular fluid shear stress at the vessel wall, have been shown to affect vessel remodelling and patency [1 4]. Studying blood flow patterns for grafted vessels may lead to an understanding of the relationship between patency and geometry. However, modelling blood flow at anastomotic junctions is difficult, due to the wide variety of vessel geometries and complex pulsatile flow. The aim of this study was to explore the effect of competing, mixing flows on flow rates for a partially obstructed coronary artery (CA) with different graft configurations. As this is a preliminary study, an approximation of the fluid geometry was created using a parametric model for ease of simulation. By varying geometry parameters, blood flow through various grafted arteries can be evaluated using computational fluid dynamics (CFD). The numerical studies presented in this work were completed with consideration of numerical accuracy and physical fidelity. Presented at the 27th Annual Meeting of the European Association for Cardio- Thoracic Surgery, Vienna, Austria, 5 9 October MATERIALS AND METHODS Geometry Flow through a partially obstructed CA was simulated using CFD with a simplified geometric model (see Fig. 1). The stenosis was modelled as a single, centred and abrupt change in vessel diameter. An optional graft was modelled as a cylindrical volume attached at a downstream location at a given angle α with respect to the artery axis. A parametric geometric model allowed for the variation of: artery internal diameter, length of the stenosis, stenosis internal diameter, distance to graft distal to stenosis exit, graft internal diameter and graft angle. As the graft vessel diameter may not necessarily match that of the artery, the crosssection of the graft cylinder was taken to be an ellipse with a minor-axis diameter matching the artery diameter. The area of this ellipse was set to be equivalent to that of a circle of diameter equal to the graft vessel internal diameter. Thus, the parametric geometry can accommodate grafts of diameter different from the artery diameter. Although this simplified geometry may appear to be a rough approximation of physical anatomy, a parametric definition is a useful tool for demonstrating relationships between flow parameters (e.g. flow rates) and geometry parameters. The Author Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

2 J.V. Lassaline and B.C. Moon / Interactive CardioVascular and Thoracic Surgery 17 Figure 1: The parametric model of fluid geometry for a simplified coronary artery including an abrupt stenosis and a bypass graft. Shown here are the parameters affecting the length of the stenosis, the point of the graft and the angle of the graft. Parameters not shown include upstream and downstream lengths, taper ratio and artery and graft diameters. Numerical simulation Simulation of blood flow through the modelled geometry was completed for a range of geometry parameters using a numerical simulation of pressure-driven flow for both steady and unsteady boundary conditions. Blood was approximated as an incompressible, non-newtonian fluid with a density of g/ml. To model the shear-thinning behaviour of blood, the Carreau Yasuda model was used to determine viscosity, with model parameters η 0 = Pa s, η = Pa s, λ = 8.2 s, a = 0.64 and n = [5, 6]. Although blood is a complex multiphase mixture, past research has shown the above model of fluid properties to be accurate for this flow regime [7]. All simulations used a second-order finite-volume spatial discretization with pressure boundary conditions set at the inlets and outlets of the geometry, and a no-slip condition at solid boundaries. Turbulence was simulated using the shear stress transport k-ω eddy-viscosity model, with inlet values of turbulent kinetic energy k = 0.24 m 2 s 2 and specific dissipation Ω = 1.78 s 1. For the given problem, this turbulence model provides an economic balance between computational accuracy and simulation costs. For steady-state simulations, pressure at the inlets was set to 120 mmhg with a pressure of 80 mmhg at the outlet. Steady-state simulations were iterated to at least five orders of convergence using the semi-implicit method for pressure linked equations scheme. For unsteady simulations, inlet pressure was set to vary from 80 to 120 mmhg according to a pulsatile waveform (see Fig. 2) approximating aortic pressure over a heartbeat cycle while the outlet back pressure was held at 80 mmhg [8]. Unsteady simulations were time-marched with second-order accuracy using the merged pressure-implicit split-operator scheme. Simulations were postprocessed to determine the mass flow rate at the inlets and outlets of the geometry. For steady-state simulations, the mass flow rate was determined from the converged solution. Unsteady flow simulations were initialized from a steady-state solution, with mass flow rates calculated as the time average over a simulation of four consecutive heartbeat cycles (e.g. see Fig. 3). Numerical studies Numerical simulations were completed using a geometry representing a 2-mm inner-diameter CA with various degrees of blockage. Blockage b was defined by the percentage of artery cross-sectional area occluded by the stenosis. Geometry parameters shown in Figure 2: Inlet pressure boundary condition modelled as a pressure pulse under normal conditions and 70 bpm. Figure 3: Flow rate history for a 2-mm internal diameter coronary artery (CA) with 50% blockage by area, with and without a 2-mm internal diameter graft. Total outflow (dashed line) is the sum of the CA inflow (short dash) and the graft inflow (dotted). In this example, the stenosis is 10-mm long and the graft is centred at 20-mm downstream from the end of the stenosis. Table 1 were combined for all combinations to produce multiple configurations. A total of 720 simulations were completed over a range of percentage of blockages with and without a 2-mm-diameter graft, for both steady and unsteady flow. The geometry was further varied by the length of the stenosis L S (5, 10 and 20-mm), the distance from the stenosis to the graft L SG (5, 10 and 20-mm) and the angle of the graft α (0, 67 and 45 ). A second study was completed to examine the influence of graft angle α on flow rates within the artery and graft. A total of 240 ORIGINAL ARTICLE

3 18 J.V. Lassaline and B.C. Moon / Interactive CardioVascular and Thoracic Surgery Table 1: Geometric parameters used in combination for each numerical study Parameter Values Distance to the graft L SG 5, 10, 20-mm Graft angle α 0, 67 and 45 Distance to the graft L SG 20-mm Graft angle α 90, 80,, 30 Distance to the graft L SG 5, 10, 15,, 30, 40, 50, 100-mm Graft angle α 45 simulations were completed over a range of percentage of blockage with a 2-mm-diameter graft located 20-mm downstream from stenoses of varied length. Figure 4: Steady-state flow rate versus percentage of blockage for a steady simulation of a 2-mm-diameter coronary artery (CA) with a 2-mm-diameter graft centred 20.0-mm downstream from a 10-mm long stenosis. Grafted artery outflow (long dash) is improved in comparison with the non-grafted artery (solid). Artery inlet flow rate (short dash) plus graft flow rate (dotted) sum to the total outflow. A third study was performed to examine the sensitivity of flow rates to the graft axial location. A total of 540 simulations were completed over a range of percentage of blockages with a 2-mm-diameter graft attached at a 45 angle. RESULTS Steady and unsteady simulations demonstrate similar flow rate sensitivities to percentage of blockage, both for the grafted and the non-grafted artery. For example, steady-state results shown in Fig. 4 demonstrate that the total outflow of the grafted artery is significantly improved in comparison with the non-grafted artery over the entire range of blockage. Note that the outflow of the grafted artery is equal to the sum of the inflow of the upstream artery and graft as required for the conservation of mass. However, the total outflow of the grafted artery is not simply double the value of the non-grafted artery due to viscous losses. These losses occur primarily due to the mixing of competing flows at the graft junction. It should be noted that the flow rate of the artery upstream of the graft junction is consistently reduced in comparison with that of the non-grafted artery. This effect is more pronounced as the percentage of blockage is increased. This is a natural consequence of the mixing of pressure-driven flows with a constrained outlet area. Similar results were found for all other simulated configurations. The imbalance of flow rates within the graft and within the upstream portion of the artery are a function of the length of the stenosis and the position of the graft. For grafts where the distance Figure 5: Time-averaged flow rate versus percentage of blockage for an unsteady simulation (four heart beats) of a 2-mm-diameter coronary artery (CA) with a 2-mm-diameter graft centred 20.0-mm downstream from a 10-mm long stenosis. between the junction and the stenosis is similar to the length of the stenosis itself, the flow rates in each vessel are closer in magnitude. For some simulations, the flow rate within the graft was less than that of the partially occluded artery; however, this only occurred at low percentage of blockage. Flow rates within the graft increase with increased artery blockage; however, at low degrees of blockage, graft flow rates are consistently less than that of the original non-grafted artery.

4 J.V. Lassaline and B.C. Moon / Interactive CardioVascular and Thoracic Surgery 19 Figure 6: Steady-state flow rates versus graft angle α for a 2-mm-diameter artery with a 2-mm-diameter graft attached at a distance of 20-mm downstream from a 10-mm long stenosis. Curves are labelled with respect to the percentage of blockage. Time-averaged unsteady results (see Fig. 5) show similar flow rate sensitivity to percentage of blockage. Unsteady results, driven by a physically realistic transient boundary condition, provide a more accurate simulation of actual flow rates, unlike steady-state results that do not match circulatory behaviour. Given that steady-state simulations require significantly less computational resources, this is a distinct advantage in exploring flow rate sensitivity to variations in geometry. As may be expected, simulations show that flow rates in grafted arteries are improved by reducing the angle between the artery and graft (see Fig. 6), regardless of the percentage of blockage. For a high degree of blockage (e.g. 90%), total outflow of the grafted artery remains high, decreasing with angle α. A similar result holds for the flow rate within the grafted artery; however, flow rates upstream of the graft junction remain relatively constant (significantly lower values compared with those of the non-grafted state) at high degrees of blockage. Simulations demonstrate that, while it is desirable to place a graft as close to the stenosis as possible, the net improvement in artery outflow is small. As can be seen in Fig. 7, grafted artery outflow remains nearly constant regardless of the distance from the stenosis to the graft junction at a higher percentage of blockage. Similar flow rate sensitivity to graft placement can be seen for the graft itself and the artery upstream of the junction. For graft placement close to the stenosis, there is an interaction between a jet flow exiting the stenosis and the incoming graft flow, producing Figure 7: Steady-state flow rates versus graft position L SG downstream from a 10-mm long stenosis within a 2-mm-diameter artery with a 2-mm-diameter graft attached at a 45 angle. Curves are labelled with respect to the percentage of blockage. strong vortices. For graft placement further away from the stenosis, this interaction is reduced as the jet expands downstream. DISCUSSION In this study, we have shown the effect of graft position and orientation on flow rates within a CA using an idealized geometric model. Steady-state simulations provide sufficient detail regarding the nature of the flow within these vessels at a substantial reduced computational cost in comparison with unsteady simulations. Flow rates within a partially obstructed artery upstream of the graft junction are significantly impeded by the addition of a graft, although the total outflow of the grafted vessel is improved. The balance of flow rates between the graft and grafted vessel are primarily dependent on the level of obstruction. In general, graft placement and orientation that minimizes strong vortices and mixing produces the highest outflow rates. Funding Computations were performed on the GPC supercomputer at the SciNet HPC Consortium. SciNet is funded by: the Canada Foundation for Innovation under the auspices of Compute Canada; the Government of Ontario; Ontario Research Fund - Research Excellence and the University of Toronto. Conflict of interest: none declared. REFERENCES [1] Ku DN, Giddens DP, Zarins CK, Glagov S. Pulsatile flow and atherosclerosis in the human carotid bifurcation. Positive correlation between plaque location and low oscillating shear stress. J Am Heart Assoc 1985;5: ORIGINAL ARTICLE

5 20 J.V. Lassaline and B.C. Moon / Interactive CardioVascular and Thoracic Surgery [2] Bertolotti C, Deplano V. Three-dimensional numerical simulations of flow through a stenosed coronary bypass. J Biomech 2000;33: [3] Sherwin SJ, Doorly DJ. Flow dynamics within model distal arterial bypass grafts. Adv Fluid Mech 2003;34: [4] Loth F, Fischer PF, Bassiouny HS. Blood flow in end-to-side anastomoses. Annu Rev Fluid Mech 2008;40: [5] Abraham F, Behr M, Heinkenschloss M. Shape optimization in steady blood flow: a numerical study of non-newtonian effects. Comput Methods Biomech Biomed Engin 2005;8: [6] Boyd J, Buick JM, Green S. Analysis of the Casson and Carreau-Yasuda non-newtonian blood models in steady and oscillatory flows using the lattice Boltzmann method. Phys Fluids 2007;19: [7] Cho Y, Kensey K. Effects of the non-newtonian viscosity of blood on flows in a diseased arterial vessel. Part 1: steady flows. Biorheology 1991;28: [8] Conlon M, Russell D, Mussivand T. Development of a mathematical model of the human circulatory system. Ann Biomed Eng 2006;34: APPENDIX: CONFERENCE DISCUSSION Dr K. Vural (Ankara, Turkey): Your presentation was very enlightening. Have you ever studied haemodynamics in sequential grafts? If so, what would be the clinical implications for daily use? Dr Moon: I don t really have the answer at the moment. Thank you for the question, because that s exactly what we are studying right now, and I m hoping that we should be able to have some results within the next couple of months. But we are actually in the process of doing all the simulations at this stage.

Numerical Simulation of Blood Flow through Asymmetric and Symmetric Occlusion in Carotid Artery

Numerical Simulation of Blood Flow through Asymmetric and Symmetric Occlusion in Carotid Artery Proceedings of the 3 rd International Conference on Fluid Flow, Heat and Mass Transfer (FFHMT 16) Ottawa, Canada May 2 3, 2016 Paper No. 170 Numerical Simulation of Blood Flow through Asymmetric and Symmetric

More information

CFD Analysis of Pulsatile Flow and Non-Newtonian Behavior of Blood in Arteries

CFD Analysis of Pulsatile Flow and Non-Newtonian Behavior of Blood in Arteries Copyright 2015 Tech Science Press MCB, vol.12, no.1, pp.37-47, 2015 CFD Analysis of Pulsatile Flow and Non-Newtonian Behavior of Blood in Arteries P. Jhunjhunwala,, P.M. Padole, and S.B. Thombre, Abstract:

More information

Contents 1 Computational Haemodynamics An Introduction 2 The Human Cardiovascular System

Contents 1 Computational Haemodynamics An Introduction 2 The Human Cardiovascular System Contents 1 Computational Haemodynamics An Introduction... 1 1.1 What is Computational Haemodynamics (CHD)... 1 1.2 Advantages of CHD... 3 1.3 Applications in the Cardiovascular System... 4 1.3.1 CHD as

More information

Numerical Simulation of Blood Flow in the System of Human Coronary Arteries with and without Bypass Graft

Numerical Simulation of Blood Flow in the System of Human Coronary Arteries with and without Bypass Graft Numerical Simulation of Blood Flow in the System of Human Coronary Arteries with and without Bypass Graft BURASKORN NUNTADILOK 1, BENCHAWAN WIWATANAPATAPHEE 1 MEECHOKE CHUEDOUNG 1, THANONGCHAI SIRIAPISITH

More information

JADAVPUR UNIVERSITY & 2 SCHOOL OF BIOSCIENCE AND ENGINEERING ABHIRUP ROY CHOUDHURY 1, KRITTIKA DASGUPTA 2, ABHIJIT CHANDA 1,2, DEBABRATA NAG 1

JADAVPUR UNIVERSITY & 2 SCHOOL OF BIOSCIENCE AND ENGINEERING ABHIRUP ROY CHOUDHURY 1, KRITTIKA DASGUPTA 2, ABHIJIT CHANDA 1,2, DEBABRATA NAG 1 Presented at the COMSOL Conference 2010 India ABHIRUP ROY CHOUDHURY 1, KRITTIKA DASGUPTA 2, ABHIJIT CHANDA 1,2, DEBABRATA NAG 1 1 DEPARTMENT OF MECHANICAL ENGINEERING & 2 SCHOOL OF BIOSCIENCE AND ENGINEERING

More information

Non-Newtonian pulsatile blood flow in a modeled artery with a stenosis and an aneurysm

Non-Newtonian pulsatile blood flow in a modeled artery with a stenosis and an aneurysm Non-Newtonian pulsatile blood flow in a modeled artery with a stenosis and an aneurysm I. Husain, C. Langdon and J. Schwark Department of Mathematics Luther College University of Regina Regina, Saskatchewan

More information

Numerical simulations of fluid mechanical interactions between two abdominal aortic branches

Numerical simulations of fluid mechanical interactions between two abdominal aortic branches Korea-Australia Rheology Journal Vol. 16, No. 2, June 2004 pp. 75-83 Numerical simulations of fluid mechanical interactions between two abdominal aortic branches Taedong Kim, Taewon Seo* 1,2 and Abdul.I.

More information

NUMERICAL STUDY OF PULSATILE BLOOD FLOW IN THE CORONARY SYSTEM WITH THE RCA BYPASS GRAFT

NUMERICAL STUDY OF PULSATILE BLOOD FLOW IN THE CORONARY SYSTEM WITH THE RCA BYPASS GRAFT Journal of Pure and Applied Mathematics: Advances and Applications Volume 9, Number 2, 2013, Pages 81-106 NUMERICAL STUDY OF PULSATILE BLOOD FLOW IN THE CORONARY SYSTEM WITH THE RCA BYPASS GRAFT BURASKORN

More information

Using Computational Fluid Dynamics Model to Predict Changes in Velocity properties in Stented Carotid Artery

Using Computational Fluid Dynamics Model to Predict Changes in Velocity properties in Stented Carotid Artery Excerpt from the Proceedings of the COMSOL Conference 2010 Paris (COMSOL Conference) Using Computational Fluid Dynamics Model to Predict Changes in Velocity properties in Stented Carotid Artery Vaidehi

More information

Arteriovenous Graft Modeling and Hemodynamic Interpretation

Arteriovenous Graft Modeling and Hemodynamic Interpretation Open Journal of Fluid Dynamics, 2012, 2, 324-330 http://dx.doi.org/10.4236/ojfd.2012.24a040 Published Online December 2012 (http://www.scirp.org/journal/ojfd) Arteriovenous Graft Modeling and Hemodynamic

More information

Refinements in Mathematical Models to Predict Aneurysm Growth and Rupture

Refinements in Mathematical Models to Predict Aneurysm Growth and Rupture Refinements in Mathematical Models to Predict Aneurysm Growth and Rupture RAMON BERGUER, a,b JOSEPH L. BULL, a,b AND KHALIL KHANAFER a a Vascular Mechanics Laboratory, Department of Biomedical Engineering,

More information

Effects of Non-Newtonian Behavior of Blood on Wall Shear Stress in an Elastic Vessel with Simple and Consecutive Stenosis

Effects of Non-Newtonian Behavior of Blood on Wall Shear Stress in an Elastic Vessel with Simple and Consecutive Stenosis Biomedical & Pharmacology Journal Vol. 8(1), 123-131 (2015) Effects of Non-Newtonian Behavior of Blood on Wall Shear Stress in an Elastic Vessel with Simple and Consecutive Stenosis M. JAHANGIRI 1 *, M.

More information

54. Simulation and research on the influence of the shape and the geometrical parameters of a blood vessel bypass graft upon hemodynamics

54. Simulation and research on the influence of the shape and the geometrical parameters of a blood vessel bypass graft upon hemodynamics 54. Simulation and research on the influence of the shape and the geometrical parameters of a blood vessel bypass graft upon hemodynamics Andžela Šešok 1, Donatas Lukšys 2 Vilnius Gediminas Technical University,

More information

Computational analysis of effects of external carotid artery flow and occlusion on adverse carotid bifurcation hemodynamics

Computational analysis of effects of external carotid artery flow and occlusion on adverse carotid bifurcation hemodynamics Computational analysis of effects of external carotid artery flow and occlusion on adverse carotid bifurcation hemodynamics Sinjae Hyun, PhD, a Clement Kleinstreuer, PhD, b and Joseph P. Archie, Jr, PhD,

More information

Simulations of the blood flow in the arterio-venous fistula for haemodialysis

Simulations of the blood flow in the arterio-venous fistula for haemodialysis Acta of Bioengineering and Biomechanics Vol. 16, No. 1, 2014 Original paper DOI: 10.5277/abb140109 Simulations of the blood flow in the arterio-venous fistula for haemodialysis DANIEL JODKO*, DAMIAN OBIDOWSKI,

More information

NUMERICAL SIMULATION OF EFFECTS OF REYNOLDS NUMBER ON NON-NEWTONIAN BLOOD FLOW WITH SPIRAL COMPONENT THROUGH A REGULAR STENOSED ARTERY

NUMERICAL SIMULATION OF EFFECTS OF REYNOLDS NUMBER ON NON-NEWTONIAN BLOOD FLOW WITH SPIRAL COMPONENT THROUGH A REGULAR STENOSED ARTERY Proceedings of the International Conference on Mechanical Engineering and Renewable Energy 2017 (ICMERE2017) 18 20 December, 2017, Chittagong, Bangladesh ICMERE2017-PI-325 NUMERICAL SIMULATION OF EFFECTS

More information

Blood flow in vessels with artificial or pathological geometrical changes

Blood flow in vessels with artificial or pathological geometrical changes Blood flow in vessels with artificial or pathological geometrical changes P. Tibaut 1, B. Wiesler 1, M. Mayer 2 & R. Wegenkittel 3 1 AVL LIST GmbH, Graz, Austria 2 VRVIs, Vienna, Austria 3 Tiani Medgraph

More information

COMPUTER SIMULATION OF BLOOD FLOW IN ARTERIES AFFECTED BY MULTIPLE ANEURYSM

COMPUTER SIMULATION OF BLOOD FLOW IN ARTERIES AFFECTED BY MULTIPLE ANEURYSM COMPUTER SIMULATION OF BLOOD FLOW IN ARTERIES AFFECTED BY MULTIPLE ANEURYSM H. GIRIJA BAI 1 and K.B. NAIDU 2 Department of Mathematics, Sathyabama University, Chennai-600 119, Tamil Nadu, India 1 girijanameprakash@gmail.com

More information

FOR many decades, cardiovascular disease has been one of

FOR many decades, cardiovascular disease has been one of Vol:1, No:2, 27 Effect of Non-Newtonian Behaviour of Blood on Pulsatile Flows in Stenotic Arteries Somkid Amornsamankul, Benchawan Wiwatanapataphee, Yong Hong Wu, Yongwimon Lenbury International Science

More information

PHYSIOLOGICAL PULSATILE WAVEFORM THROUGH AXISYMMETRIC STENOSED ARTERIES: NUMERICAL SIMULATION

PHYSIOLOGICAL PULSATILE WAVEFORM THROUGH AXISYMMETRIC STENOSED ARTERIES: NUMERICAL SIMULATION PHYSIOLOGICAL PULSATILE WAVEFORM THROUGH AXISYMMETRIC STENOSED ARTERIES: NUMERICAL SIMULATION Jayme Pinto Ortiz University of São Paulo - Avenida Prof. Luciano Gualberto, travessa3 nº 380 - CEP - 05508-900

More information

Analysis of the effects of plaque deposits on the blood flow through human artery

Analysis of the effects of plaque deposits on the blood flow through human artery ISSN 2395-1621 Analysis of the effects of plaque deposits on the blood flow through human artery #1 Sajid S. Mulani, #2 Pankaj I. Jagad 1 sajidsmulani21@gmail.com 2 pjjagad.scoe@sinhgad.edu #12 Department

More information

Simulation of Blood Flow Coronary Artery with Consecutive Stenosis and Coronary-Coronary Bypass

Simulation of Blood Flow Coronary Artery with Consecutive Stenosis and Coronary-Coronary Bypass BioImpacts, 2011, 1(2), 99-104 http://bi.tbzmed.ac.ir/ Simulation of Blood Flow Coronary Artery with Consecutive Stenosis and Coronary-Coronary Bypass Seyed Esmail Razavi *, Ramin Zanbouri, Omid Arjmandi-Tash

More information

A Two-layered Model for the Analysis of Arterial Rheology

A Two-layered Model for the Analysis of Arterial Rheology IJCSIT International Journal of Computer Science and Information Technology, Vol., o., June, pp. 37- A Two-layered Model for the Analysis of Arterial Rheology Sapna Singh Department of Mathematics, Harcourt

More information

Hematocrit Level on Blood flow through a Stenosed Artery with Permeable Wall: A Theoretical Study

Hematocrit Level on Blood flow through a Stenosed Artery with Permeable Wall: A Theoretical Study Available at http://pvamu.edu/aam Appl. Appl. Math. ISSN: 1932-9466 Vol. 12, Issue 1 (June 2017), pp. 291-304 Applications and Applied Mathematics: An International Journal (AAM) Hematocrit Level on Blood

More information

Asymmetric flows of non-newtonian fluids in symmetric stenosed artery

Asymmetric flows of non-newtonian fluids in symmetric stenosed artery Korea-Australia Rheology Journal Vol. 16, No. 2, June 2004 pp. 101-108 Asymmetric flows of non-newtonian fluids in symmetric stenosed artery Hun Jung*, Jong Wook Choi 1 and Chan Guk Park 2 Graduate School,

More information

Computational Fluid Dynamics Analysis of Blalock-Taussig Shunt

Computational Fluid Dynamics Analysis of Blalock-Taussig Shunt Washington University in St. Louis Washington University Open Scholarship Mechanical Engineering and Materials Science Independent Study Mechanical Engineering & Materials Science 12-23-2017 Computational

More information

Simulations of pulsatile blood flow in tapered S-shaped inplane and out-of-plane coronary arteries

Simulations of pulsatile blood flow in tapered S-shaped inplane and out-of-plane coronary arteries Simulations of pulsatile blood flow in tapered S-shaped inplane and out-of-plane coronary arteries Author Johnston, Barbara, Johnston, Peter Published 2009 Conference Title 18th IMACS World Congress MODSIM09

More information

EFFECT OF BRANCHINGS ON BLOOD FLOW IN THE SYSTEM OF HUMAN CORONARY ARTERIES. Benchawan Wiwatanapataphee. Yong Hong Wu. Thanongchai Siriapisith

EFFECT OF BRANCHINGS ON BLOOD FLOW IN THE SYSTEM OF HUMAN CORONARY ARTERIES. Benchawan Wiwatanapataphee. Yong Hong Wu. Thanongchai Siriapisith MATHEMATICAL BIOSCIENCES doi:10.3934/mbe.2012.9.199 AND ENGINEERING Volume 9, Number 1, January 2012 pp. 199 214 EFFECT OF BRANCHINGS ON BLOOD FLOW IN THE SYSTEM OF HUMAN CORONARY ARTERIES Benchawan Wiwatanapataphee

More information

On the Existence of an Optimum End-to-side Junctional Geometry in Peripheral Bypass Surgery A Computer Generated Study

On the Existence of an Optimum End-to-side Junctional Geometry in Peripheral Bypass Surgery A Computer Generated Study Eur J Vasc Endovasc Surg 26, 649 656 (2003) doi: 10.1016/j.ejvs.2003.08.004, available online at http://www.sciencedirect.com on On the Existence of an Optimum End-to-side Junctional Geometry in Peripheral

More information

CPM Specifications Document Aortofemoral Normal:

CPM Specifications Document Aortofemoral Normal: CPM Specifications Document Aortofemoral Normal: OSMSC 0110_0000 May 27, 2013 Version 1 Open Source Medical Software Corporation 2013 Open Source Medical Software Corporation. All Rights Reserved. 1. Clinical

More information

Deposited on: 21 January 2009

Deposited on: 21 January 2009 Paul, M.C. and Molla, M.M. and Roditi, G. (2009) Large-Eddy simulation of pulsatile blood flow. Medical Engineering and Physics, 31 (1). pp. 153-159. ISSN 1350-4533 http://eprints.gla.ac.uk/4891/ Deposited

More information

Analysis of the GPATD : Geometrical Influence on Blood Clot Extraction using CFD Simulation

Analysis of the GPATD : Geometrical Influence on Blood Clot Extraction using CFD Simulation 2014 UKSim-AMSS 16th International Conference on Computer Modelling and Simulation Analysis of the GPATD : Geometrical Influence on Blood Clot Extraction using CFD Simulation Gregorio Romero, M.Luisa Martínez

More information

CPM Specifications Document Aortofemoral Normal:

CPM Specifications Document Aortofemoral Normal: CPM Specifications Document Aortofemoral Normal: OSMSC 0003_0000 0006_0000 May 24, 2013 Version 1 Open Source Medical Software Corporation 2013 Open Source Medical Software Corporation. All Rights Reserved.

More information

CPM Specifications Document Aortic Coarctation: Exercise

CPM Specifications Document Aortic Coarctation: Exercise CPM Specifications Document Aortic Coarctation: Exercise OSMSC 0091_2000 0102_2000 0107_0000 0111_0000 May 29, 2013 Version 1 Open Source Medical Software Corporation 2013 Open Source Medical Software

More information

Vascular reconstruction: CFD predictions of bypass graft haemodynamics

Vascular reconstruction: CFD predictions of bypass graft haemodynamics Vascular reconstruction: CFD predictions of bypass graft haemodynamics J.S. Cole 1, J.K. Watterson 1 & M.J.G. O Reilly 2 1 School of Mechanical and Aerospace Engineering, The Queen s University of Belfast,

More information

There has been extensive speculation in the literature about

There has been extensive speculation in the literature about TECHNICAL NOTE A. Mantha C. Karmonik G. Benndorf C. Strother R. Metcalfe Hemodynamics in a Cerebral Artery before and after the Formation of an Aneurysm SUMMARY: Using data obtained from 3D digital subtraction

More information

Blood flow in S-shaped in-plane and out-of-plane coronary arteries

Blood flow in S-shaped in-plane and out-of-plane coronary arteries Blood flow in S-shaped in-plane and out-of-plane coronary arteries Author Johnston, Peter, Johnston, Barbara Published 2008 Journal Title The A N Z I A M Journal DOI https://doi.org/10.21914/anziamj.v49i0.330

More information

Blood Flow Simulation toward Actual Application at Hospital

Blood Flow Simulation toward Actual Application at Hospital THE 5 TH ASIAN COMPUTAITIONAL FLUID DYNAMICS BUSAN, KOREA, OCTOBER 27 ~ OCTOBER 30, 2003 Blood Flow Simulation toward Actual Application at Hospital Abstract R. Himeno 1 1. Advanced Center for Computing

More information

Post-conditioning. P a g e 1. To my Thesis Committee,

Post-conditioning. P a g e 1. To my Thesis Committee, P a g e 1 To my Thesis Committee, This document seeks to clarify my research project. After describing what post-conditioning (PC) is, I will explain differences between my research and the recent peristaltic

More information

Physiological flow analysis in significant human coronary artery stenoses

Physiological flow analysis in significant human coronary artery stenoses Biorheology 40 (2003) 451 476 451 IOS Press Physiological flow analysis in significant human coronary artery stenoses Rupak K. Banerjee a,, Lloyd H. Back b, Martin R. Back c and Young I. Cho d a Department

More information

CARDIOVASCULAR disease is a leading cause of morbidity

CARDIOVASCULAR disease is a leading cause of morbidity Changes in velocity profiles in a two dimensional carotid artery geometry in response to changes in velocity waveforms and a simulated stenosis growth: A lattice Boltzmann Simulation J Boyd, and J M Buick

More information

A Review of Study of the Effects of Plaque Deposits on the Blood Flow through Human Artery

A Review of Study of the Effects of Plaque Deposits on the Blood Flow through Human Artery A Review of Study of the Effects of Plaque Deposits on the Blood Flow through Human Artery 1 Sajid S. Mulani, 2 P. I. Jagad 1,2 Department of Mechanical Engineering, SCoE, Pune 411041, India Email: 1 sajidsmulani21@gmail.com,

More information

Mathematical Modeling of Bingham Plastic Model of Blood Flow Through Stenotic Vessel

Mathematical Modeling of Bingham Plastic Model of Blood Flow Through Stenotic Vessel RESEARCH ARTICLE OPEN ACCESS Mathematical Modeling of Bingham Plastic Model of Blood Flow Through Stenotic Vessel S.R. Verma Department of Mathematics, D.A-V. (P.G.) College, Kanpur-208001, India Abstract

More information

Non-axisymmetric Flow Development in Pulsatile Blood Flow through an Aneurysm

Non-axisymmetric Flow Development in Pulsatile Blood Flow through an Aneurysm 16 th Australasian Fluid Mechanics Conference Crown Plaza, Gold Coast, Australia 2-7 December 2007 Non-axisymmetric Flow Development in Pulsatile Blood Flow through an Aneurysm R.A. Jamison 1,2, G.J. Sheard

More information

Assessment of the Effects of Increasing Levels of Physiological Realism in the Computational Fluid Dynamics Analyses of Implanted Coronary Stents

Assessment of the Effects of Increasing Levels of Physiological Realism in the Computational Fluid Dynamics Analyses of Implanted Coronary Stents Dublin Institute of Technology ARROW@DIT Conference Papers School of Mechanical and Design Engineering 2008-09-01 Assessment of the Effects of Increasing Levels of Physiological Realism in the Computational

More information

¼ density (kg/m 3 ) ij ¼ Reynolds stress tensor (kg/m-s 2 ) ! ¼ specific dissipation rate ("=k)

¼ density (kg/m 3 ) ij ¼ Reynolds stress tensor (kg/m-s 2 ) ! ¼ specific dissipation rate (=k) The current issue and full text archive of this journal is available at www.emeraldinsight.com/0961-5539.htm Numerical simulation of pulsatile turbulent flow in tapering stenosed arteries Bin Xiao and

More information

Study of Newtonian and Non-Newtonian Effect of Blood Flow in Portal Vein in Normal and Hypertension Conditions using CFD Technique

Study of Newtonian and Non-Newtonian Effect of Blood Flow in Portal Vein in Normal and Hypertension Conditions using CFD Technique International Journal of Engineering Research and Technology. ISSN 0974-3154 Volume 6, Number 3 (2013), pp. 399-406 International Research Publication House http://www.irphouse.com Study of Newtonian and

More information

EasyChair Preprint. Computational Fluid Dynamics Simulations of Flow in the Renal Arteries after Stent Graft Implantation

EasyChair Preprint. Computational Fluid Dynamics Simulations of Flow in the Renal Arteries after Stent Graft Implantation EasyChair Preprint 259 Computational Fluid Dynamics Simulations of Flow in the Renal Arteries after Stent Graft Implantation Tianyi Xia, Matthew Doyle, Thomas Forbes and Cristina H. Amon EasyChair preprints

More information

FLUID MECHANICAL PERTURBATIONS INDUCED BY STENT IMPLANTATION: A NUMERICAL STUDY

FLUID MECHANICAL PERTURBATIONS INDUCED BY STENT IMPLANTATION: A NUMERICAL STUDY LABORATORY OF BIOLOGICAL STRUCTURE MECHANICS www.labsmech.polimi.it FLUID MECHANICAL PERTURBATIONS INDUCED BY STENT IMPLANTATION: A NUMERICAL STUDY Rossella Balossino, Francesca Gervaso, Francesco Migliavacca,

More information

BLOOD SIMULATION AND VIRTUAL BYPASS SURGERY

BLOOD SIMULATION AND VIRTUAL BYPASS SURGERY Integrity, Reliability and Failure of Mechanical Systems PAPER REF: 3947 (Invited Paper) BLOOD SIMULATION AND VIRTUAL BYPASS SURGERY Catarina F. Castro 1,2(*), Carlos C. António 1,2, Luisa C. Sousa 1,2

More information

Research Article Hemodynamic Features in Stenosed Coronary Arteries: CFD Analysis Based on Histological Images

Research Article Hemodynamic Features in Stenosed Coronary Arteries: CFD Analysis Based on Histological Images Applied Mathematics Volume, Article ID 77, pages http://dx.doi.org/.//77 Research Article Hemodynamic Features in Stenosed Coronary Arteries: CFD Analysis Based on Histological Images Mahsa Dabagh,, Wakako

More information

Flow in re-stenosed artery after angioplasty

Flow in re-stenosed artery after angioplasty Data Management and Security 209 Flow in re-stenosed artery after angioplasty S. I. Bernad 1, A. Totorean 2, E. S. Bernad 3 & R. Susan-Resiga 2 1 Romanian Academy, Timisoara Branch, Romania 2 Politehnica

More information

Numerical investigation on the blood flow characteristics considering the axial rotation in stenosed artery

Numerical investigation on the blood flow characteristics considering the axial rotation in stenosed artery Korea-Australia Rheology Journal Vol. 21, No. 2, June 2009 pp. 119-126 Numerical investigation on the blood flow characteristics considering the axial rotation in stenosed artery Kun Hyuk Sung, Kyoung

More information

Mathematical and Computational study of blood flow through diseased artery

Mathematical and Computational study of blood flow through diseased artery Mathematical and Computational study of blood flow through diseased artery Abstract This paper presents the study of blood flow through a tapered stenosed artery. The fluid (blood) medium is assumed to

More information

Calculation of the Wall Shear Stress in the case of an Internal Carotid Artery with stenoses of different sizes

Calculation of the Wall Shear Stress in the case of an Internal Carotid Artery with stenoses of different sizes Calculation of the Wall Shear Stress in the case of an Internal Carotid Artery with stenoses of different sizes Titus PETRILA 1, Balazs ALBERT,2 Corresponding author 1 Vasile Goldis Western University,

More information

STUDY OF FLOW PHENOMENA IN AORTIC DISSECTION

STUDY OF FLOW PHENOMENA IN AORTIC DISSECTION STUDY OF FLOW PHENOMENA IN AORTIC DISSECTION Maurizio Bordone *, Eugenio Oñate *, Paula Rudenick, Bart Bijnens and Eduardo Soudah * * International Centre for Numerical Methods in Engineering (CIMNE) Campus

More information

Design and Simulation of Blocked Blood Vessel for Early Detection of Heart Diseases

Design and Simulation of Blocked Blood Vessel for Early Detection of Heart Diseases Proceedings of the 215 2nd International Symposium on Physics and Technology of Sensors, 8-1th March, 215, Pune, India Design and Simulation of Blocked Blood Vessel for Early Detection of Heart Diseases

More information

Numerical Simulation of Blood Flow in the System of Human Coronary Arteries with Stenosis

Numerical Simulation of Blood Flow in the System of Human Coronary Arteries with Stenosis Numerical Simulation of Blood Flow in the System of Human Coronary Arteries with Stenosis PEARANAT CHUCHARD 1, BENCHAWAN WIWATANAPATAPHEE 1, THITIKOM PUAPANSAWAT 1, THANONGCHAI SIRIAPISITH 2 1 Department

More information

Finite Element Modeling of Three-Dimensional Pulsatile Flow in the Abdominal Aorta: Relevance to Atherosclerosis

Finite Element Modeling of Three-Dimensional Pulsatile Flow in the Abdominal Aorta: Relevance to Atherosclerosis Annals of Biomedical Engineering, Vol. 26, pp. 975 987, 1998 0090-6964/98 $10.50.00 Printed in the USA. All rights reserved. Copyright 1998 Biomedical Engineering Society Finite Element Modeling of Three-Dimensional

More information

Non-Newtonian blood flow in human right coronary arteries: Transient simulations

Non-Newtonian blood flow in human right coronary arteries: Transient simulations Non-Newtonian blood flow in human right coronary arteries: Transient simulations Author Johnston, Barbara, Johnston, Peter, Corney, Stuart, Kilpatrick, David Published 2006 Journal Title Journal of Biomechanics

More information

CFD Challenge: Simulation of Hemodynamics in a Patient-Specific Aortic Coarctation Model

CFD Challenge: Simulation of Hemodynamics in a Patient-Specific Aortic Coarctation Model CFD Challenge: Simulation of Hemodynamics in a Patient-Specific Aortic Coarctation Model Background Coarctation of the aorta (CoA) accounts for 8%-11% of congenital heart defects, affecting tens of thousands

More information

DYNAMIC BLOOD FLOW IN A LEFT VENTRICLE

DYNAMIC BLOOD FLOW IN A LEFT VENTRICLE DYNAMIC BLOOD FLOW IN A LEFT VENTRICLE Hidehito IWASE 1, Hao LIU 2, Shinichi FUJIMOTO 3, Ryutaro HIMENO 4 1 Computer Information Center and Advanced Engineering Center, RIKEN 2-1, Hirosawa, Wako-shi, Saitam

More information

A Review: Hemodynamics of Cerebral Aneurysm with Mathematical Modeling

A Review: Hemodynamics of Cerebral Aneurysm with Mathematical Modeling International Mathematical Forum, Vol. 7, 2012, no. 54, 2687-2693 A Review: Hemodynamics of Cerebral Aneurysm with Mathematical Modeling Duangkamol Poltem Department of Mathematics, Faculty of Science

More information

Simulation of blood flow through endovascular prosthesis in patients with Abdominal Aortic Aneurysm

Simulation of blood flow through endovascular prosthesis in patients with Abdominal Aortic Aneurysm Simulation of blood flow through endovascular prosthesis in patients with Abdominal Aortic Aneurysm Andrzej Polańczyk, MSc Ireneusz Zbiciński, PhD, DSc Abstract The aim of this study was to estimate whether

More information

Steady State Computer Model of Human Vascular for Analyzing Effects of Stenosis

Steady State Computer Model of Human Vascular for Analyzing Effects of Stenosis Steady State Computer Model of Human Vascular for Analyzing Effects of Stenosis University of Illinois at Chicago Professor Andreas Linninger Michael Naskrent December 2, 2013 Table of Contents Abstract...

More information

UNIVERSITY OF CINCINNATI

UNIVERSITY OF CINCINNATI UNIVERSITY OF CINCINNATI Date: 5-Nov-2010 I, Justin Niehaus, hereby submit this original work as part of the requirements for the degree of: Master of Science in Aerospace Engineering It is entitled: Use

More information

Experimental Flow Studies on Carotid Artery Models with and without Stents

Experimental Flow Studies on Carotid Artery Models with and without Stents Experimental Flow Studies on Carotid Artery Models with and without Stents Liepsch, D 1, Schmid, Th. 1, Klügel, G. 1, Sakurai, A. 3, Berger, H. 2, Greil, O. 2 1 FB 05, Fachhochschule München, Lothstr.

More information

Quantifying turbulent wall shear stress in a subject specific human aorta using large eddy simulation

Quantifying turbulent wall shear stress in a subject specific human aorta using large eddy simulation Quantifying turbulent wall shear stress in a subject specific human aorta using large eddy simulation Jonas Lantz, Roland Gårdhagen and Matts Karlsson Linköping University Post Print N.B.: When citing

More information

Estimation and Comparison of T Graft Versus Conventional Graft for Coronary Arteries

Estimation and Comparison of T Graft Versus Conventional Graft for Coronary Arteries World Applied Sciences Journal 27 (10): 1336-1344, 2013 ISSN 1818-4952 IDOSI Publications, 2013 DOI: 10.5829/idosi.wasj.2013.27.10.2908 Estimation and Comparison of T Graft Versus Conventional Graft for

More information

Computational Fluid Dynamics Analysis of Blood Flow in Human Aorta

Computational Fluid Dynamics Analysis of Blood Flow in Human Aorta Computational Fluid Dynamics Analysis of Blood Flow in Human Aorta Yogesh V. Borse 1, Prof. S.A. Giri 2 M. Tech Scholar, Dept of Mechanical Engg, Ramdeobaba College of Engineering and Management, Nagpur,

More information

Effects of surface geometry and non-newtonian viscosity on the flow field in arterial stenoses

Effects of surface geometry and non-newtonian viscosity on the flow field in arterial stenoses Journal of Mechanical Science and Technology 23 (2009) 2424~2433 Journal of Mechanical Science and Technology www.springerlink.com/content/1738-494x DOI 10.1007/s12206-009-0627-6 Effects of surface geometry

More information

ISSUES ON COMPUTATIONAL MODELING FOR COMPUTATION-AIDED DIAGNOSIS 臨床診断支援ツールのための計算力学モデリング

ISSUES ON COMPUTATIONAL MODELING FOR COMPUTATION-AIDED DIAGNOSIS 臨床診断支援ツールのための計算力学モデリング ISSUES ON COMPUTATIONAL MODELING FOR COMPUTATION-AIDED DIAGNOSIS 臨床診断支援ツールのための計算力学モデリング Hao LIU Advanced Computer and Information Division, RIKEN 2-1, Hirosawa, Wako-shi, Saitama 351-0198 JAPAN e-mail:

More information

CFD Study of the Blood Flow in Cerebral Aneurysms Treated with Flow Diverter Stents

CFD Study of the Blood Flow in Cerebral Aneurysms Treated with Flow Diverter Stents CFD Study of the Blood Flow in Cerebral Aneurysms Treated with Flow Diverter Stents Augusto F. Sanches and Eva Gutheil Interdisciplinary Center for Scientific Computing, Heidelberg University Flow diverters

More information

A Computational Fluid Dynamics Study on Bidirectional Glenn Shunt Flow with an Additional Pulsatile Flow Through a modified Blalock-Taussig Shunt

A Computational Fluid Dynamics Study on Bidirectional Glenn Shunt Flow with an Additional Pulsatile Flow Through a modified Blalock-Taussig Shunt University of New Orleans ScholarWorks@UNO University of New Orleans Theses and Dissertations Dissertations and Theses Spring 5-19-2017 A Computational Fluid Dynamics Study on Bidirectional Glenn Shunt

More information

Closed-loop CFD Model of the Self-Powered Fontan Circulation for the Hypoplastic Left Heart Syndrome

Closed-loop CFD Model of the Self-Powered Fontan Circulation for the Hypoplastic Left Heart Syndrome McNair Scholars Research Journal Volume 3 Article 4 016 Closed-loop CFD Model of the Self-Powered Fontan Circulation for the Hypoplastic Left Heart Syndrome Nathalie E. Quintero Embry-Riddle Aeronautical

More information

A Mathematical Model for Flow and Diffusion through Stenotic Capillary-Tissue Exchange System

A Mathematical Model for Flow and Diffusion through Stenotic Capillary-Tissue Exchange System 1 A Mathematical Model for Flow and Diffusion through Stenotic Capillary-Tissue Exchange System Shailesh Mishra *, S.U.Siddiqui Department of Mathematics Harcourt Butler Technological Institute Kanpur-282,

More information

Computational design of Intracranial Stent using 3D visualization system

Computational design of Intracranial Stent using 3D visualization system Computational design of Intracranial Stent using 3D visualization system Institute of Fluid Science, Tohoku University Makoto OHTA Graduate school of Engineering Hitomi Anzai Graduate school of Biomedical

More information

Particle Hemodynamics Analysis after Coronary Angioplasty

Particle Hemodynamics Analysis after Coronary Angioplasty , June 30 - July 2, 2010, London, U.K. Particle Hemodynamics Analysis after Coronary Angioplasty S.I. Bernad, A.F. Totorean, V.F. Vinatu, R.F. Susan-Resiga Abstract The resistance to flow through a stenosis

More information

A numerical study on the effect of hematocrit on hemodynamic characteristics in arteriovenous graft

A numerical study on the effect of hematocrit on hemodynamic characteristics in arteriovenous graft Korea-Australia Rheology Journal, Vol.26, No.3, pp.327-334 (August 2014) DOI: 10.1007/s13367-014-0037-x www.springer.com/13367 A numerical study on the effect of hematocrit on hemodynamic characteristics

More information

Translating In-vitro and Computational Multi-scale Models for the Vascular Surgeon

Translating In-vitro and Computational Multi-scale Models for the Vascular Surgeon Translating In-vitro and Computational Multi-scale Models for the Vascular Surgeon Benjamin A. Eslahpazir MS, BSME 1, Kyle W. Beggs 2, Zoe M. Lauters 2 Alain J. Kassab PhD 2 William M. DeCampli MD, PhD

More information

Journal of Biomechanics

Journal of Biomechanics Journal of Biomechanics ] (]]]]) ]]] ]]] Contents lists available at SciVerse ScienceDirect Journal of Biomechanics journal homepage: www.elsevier.com/locate/jbiomech www.jbiomech.com Flow resistance analysis

More information

Medical device design using Computational Fluid Dynamics (CFD)

Medical device design using Computational Fluid Dynamics (CFD) Medical device design using Computational Fluid Dynamics (CFD) Session: Winter 2016 IMPORTANT NOTE: This project has 8 deliverables, for each one timely work is expected. 1. General Design Specifications

More information

Effect of exercise on hemodynamic conditions in the abdominal aorta

Effect of exercise on hemodynamic conditions in the abdominal aorta BASIC RESEARCH PAPERS Effect of exercise on hemodynamic conditions in the abdominal aorta Charles A. Taylor, PhD, Thomas J.R. Hughes, PhD, and Christopher K. Zarins, MD, Stanford, Calif Purpose: The beneficial

More information

4D model of hemodynamics in the abdominal aorta

4D model of hemodynamics in the abdominal aorta Bio-Medical Materials and Engineering 26 (2015) S257 S264 DOI 10.3233/BME-151312 IOS Press S257 4D model of hemodynamics in the abdominal aorta Ireneusz Zbicinski a,*, Natalia Veshkina a and Ludomir Stefa

More information

An Evaluation of Proposed and Current Cardiovascular Stent Design Approaches to Aortoiliac Occlusive Disease

An Evaluation of Proposed and Current Cardiovascular Stent Design Approaches to Aortoiliac Occlusive Disease Washington University in St. Louis Washington University Open Scholarship Engineering and Applied Science Theses & Dissertations Engineering and Applied Science Spring 5-18-2018 An Evaluation of Proposed

More information

History of Vascular Modelling. William Harvey discovery of the circulation 1628

History of Vascular Modelling. William Harvey discovery of the circulation 1628 History of Vascular Modelling William Harvey discovery of the circulation 1628 William Harvey (1578-1657) Since all things, both argument and ocular demonstration, show that the blood passes through the

More information

BLOOD FLOW THROUGH A COMPOSITE STENOSIS IN CATHETERIZED ARTERIES INTRODUCTION

BLOOD FLOW THROUGH A COMPOSITE STENOSIS IN CATHETERIZED ARTERIES INTRODUCTION 55 BLOOD FLOW THROUGH A COMPOSITE STENOSIS IN CATHETERIZED ARTERIES V P Srivastava, Rochana Vishnoi, Shailesh Mishra, Poonam Sinha * Department of Mathematics, Krishna Girls Engineering College, Kanpur-917,

More information

Numerical Study on Vascular Grafts Prototypes

Numerical Study on Vascular Grafts Prototypes 51, Issue 2 (2018) 99-107 Journal of Advanced Research in Fluid Mechanics and Thermal Sciences Journal homepage: www.akademiabaru.com/arfmts.html ISSN: 2289-7879 Numerical Study on Vascular Grafts Prototypes

More information

Modeling Flow Characteristics in Carotid Artery Bifurcation Afflicted with Atherosclerotic Plaques

Modeling Flow Characteristics in Carotid Artery Bifurcation Afflicted with Atherosclerotic Plaques Modeling Flow Characteristics in Carotid Artery Bifurcation Afflicted with Atherosclerotic Plaques BEE 4530 Spring 2013 Group 8 Alexandra Braun Stellie Justin Ford Marina Shumakovich Alden Sonnenfeldt

More information

The relative effects of arterial curvature and lumen diameter on wall shear stress distributions in human right coronary arteries

The relative effects of arterial curvature and lumen diameter on wall shear stress distributions in human right coronary arteries The relative effects of arterial curvature and lumen diameter on wall shear stress distributions in human right coronary arteries Author Johnston, Barbara, Johnston, Peter Published 2007 Journal Title

More information

Computational fluid dynamics study of the end-side and sequential coronary artery bypass anastomoses in a native coronary occlusion model

Computational fluid dynamics study of the end-side and sequential coronary artery bypass anastomoses in a native coronary occlusion model Interactive CardioVascular and Thoracic Surgery 26 (2018) 583 589 doi:10.1093/icvts/ivx376 Advance Access publication 27 November 2017 ORIGINAL ARTICLE Cite this article as: Matsuura K, Jin WW, Liu H,

More information

Medical Engineering & Physics

Medical Engineering & Physics Medical Engineering & Physics 33 (2011) 315 324 Contents lists available at ScienceDirect Medical Engineering & Physics journal homepage: www.elsevier.com/locate/medengphy 3D pulsatile flow in a curved

More information

A New System to Analyze Pulsatile Flow Characteristics in Elastic Tubes for Hemodynamic Applications

A New System to Analyze Pulsatile Flow Characteristics in Elastic Tubes for Hemodynamic Applications American Journal of Applied Sciences 5 (12): 1730-1736, 2008 ISSN 1546-9239 2008 Science Publications A New System to Analyze Pulsatile Flow Characteristics in Elastic Tubes for Hemodynamic Applications

More information

Computational medical imaging and hemodynamics framework for functional analysis and assessment of cardiovascular structures

Computational medical imaging and hemodynamics framework for functional analysis and assessment of cardiovascular structures DOI 10.1186/s12938-017-0326-y BioMedical Engineering OnLine REVIEW Open Access Computational medical imaging and hemodynamics framework for functional analysis and assessment of cardiovascular structures

More information

Comparison of Stent Designs using Computational Fluid Dynamics

Comparison of Stent Designs using Computational Fluid Dynamics Dublin Institute of Technology ARROW@DIT Conference Papers School of Mechanical and Design Engineering 2007-03-28 Comparison of Stent Designs using Computational Fluid Dynamics Jonathan Murphy Dublin Institute

More information

Dynamic Role of the Cardiac Jelly

Dynamic Role of the Cardiac Jelly 61 Chapter 6 Dynamic Role of the Cardiac Jelly Before looping, when the embryonic heart is still a straight tube, the cardiac jelly occupies the bulk of the heart tube walls. Despite its preeminence in

More information

BLOOD FLOW ANALYSIS OF STA-MCA ANASTOMOSIS USING CFD

BLOOD FLOW ANALYSIS OF STA-MCA ANASTOMOSIS USING CFD VI International Conference on Computational Bioengineering ICCB 2015 M. Cerrolaza and S.Oller (Eds) BLOOD FLOW ANALYSIS OF - ANASTOMOSIS USING CFD SHO TAKAYAMA *1, MITSUYOSHI WATANABE 2, HIROYUKI TAKAO

More information

Studying the Flow Dynamics Within Endografts in Abdominal Aortic Aneurysms

Studying the Flow Dynamics Within Endografts in Abdominal Aortic Aneurysms Chapter 8 Studying the Flow Dynamics Within Endografts in Abdominal Aortic Aneurysms Efstratios Georgakarakos, Antonios Xenakis, George S. Georgiadis, Konstantinos C. Kapoulas, Evagelos Nikolopoulos and

More information

Previous talks. Clinical applications for spiral flow imaging. Clinical applications. Clinical applications. Coronary flow: Motivation

Previous talks. Clinical applications for spiral flow imaging. Clinical applications. Clinical applications. Coronary flow: Motivation for spiral flow imaging Joao L. A. Carvalho Previous talks Non-Cartesian reconstruction (2005) Spiral FVE (Spring 2006) Aortic flow Carotid flow Accelerated spiral FVE (Fall 2006) 2007? Department of Electrical

More information

A STUDY ON VASCULAR RECONSTRUCTION BY FLOW VISUALIZATION*

A STUDY ON VASCULAR RECONSTRUCTION BY FLOW VISUALIZATION* Nagoya J. med. Sci. 36: 91-100, 197-1 A STUDY ON VASCULAR RECONSTRUCTION BY FLOW VISUALIZATION* MASARU ESAKI 1st Departmetlt of Surgery, Nagoya University School of Medicine (Director: Prof. Yotaro lyomasa)

More information