DIABETES TECHNOLOGY: WHERE ARE WE NOW AND WHERE ARE WE GOING? Presented by: Tom Brobson
|
|
- Bryan Gilmore
- 6 years ago
- Views:
Transcription
1 DIABETES TECHNOLOGY: WHERE ARE WE NOW AND WHERE ARE WE GOING? Presented by: Tom Brobson March 3 rd, 2018
2 Who is this guy? Accelerating Progress 1
3 Oh that guy! Accelerating Progress 2
4 STATE OF T1D CARE Technology of the Past 3
5 GLUCOSE MONITORING 4
6 Blood Glucose Meter Accuracy 17 meters: MARD=5.6%-20.8% 9 with MARD >10% Ekhlaspour et al, JDST 2017
7 Continuous Glucose Monitors CGM system consists of a sensor, transmitter, and receiver (mobile phone) Measures glucose concentration in interstitial fluid
8 CGM Metrics Overall Control Mean Glucose Time in range (70 180mg/dL) Hyperglycemia Hypoglycemia Glycemic Variability
9 First Real-time CGM GlucoWatch G2 Biographer FDA approved for adults in 2001 and children 7-17 yrs old in 2002
10 Real-time CGMs circa 2008 Dexcom: SEVEN Sensor (FDA approved for adults in 2006) Medtronic: Guardian REAL-Time Sensor (FDA approved for adults/children in 2005) Abbott: FreeStyle Navigator (FDA approved for adults in 2008)
11
12 Current CGM Sensors Dexcom G5 Abbott Libre Flash Glucose Monitor Medtronic Enlite 3 and ipro2 (blinded only) Coming soon in U.S. Sensionics Eversense (available in Europe) Dexcom G6
13 Dexcom G5
14 Abbott FreeStyle Libre 14-day sensor Factory calibrated swipe
15
16 CGM Accuracy Over Time Abbott Libre (12.3%) Medtronic Enlite 3 (10.5%) Faccinetti A. Sensors 2016
17 Accuracy of CGM Sensors MARD Within 20 mg/dl or 20% Dexcom G5 9.0% 93% Medtronic Enlite % 88% Abbott Libre 12.3%* 84% Eversense 8.8% 93% Dexcom G6 8.1% 96% MARD= Mean Absolute Relative Difference *9.7% after first 12 hrs on day 1 through 10 days
18 Coming Soon: Dexcom G6 Sensor 10 Day Duration Sensor Acetaminophen Blocking Factory Calibrated 30% Thinner Wearable Simple, Push Button Sensor Applicator
19 The Eversense System Sensor Smart Transmitter Mobile App Sensor lasts up to 180 days Removable and rechargeable On-body vibe alerts Gentle-on-skin adhesive No extra device to carry ios and Android platform Alarm settings & reports 18
20 Several Other Players Glysens Profusa Biorasis Capillary Biomedical GluSense
21 JDRF RESEARCH Better Outcomes in T1D Pregnancies The CONCEPTT study shows that use of continuous glucose monitoring (CGM) during pregnancy improves health outcomes for both mothers and babies Women with T1D who used a CGM experienced better glucose control, spending an extra 100 minutes per day with blood sugars in a healthy range Their babies were more likely to be born with a healthy birthweight and less likely to have hypoglycemia post-partum or to require intensive care Funded by JDRF, this study is the largest clinical trial conducted to date with pregnant women with T1D -- it included 325 women from 31 hospitals in seven countries over 5+ years We hope the results will encourage the use of CGM in women with T1D, particularly during pregnancy We also hope this multi-national clinical trial will lead to improved access to technologies and evolving standards of clinical care worldwide EASD conference, September 2017 Lancet 390, (2017)
22 Real World Result! 21
23 Artificial Pancreas Enable more effective and improved glucose control with significantly less burden 22
24 Smart Pens HumaPen Memoir pen (Eli Lilly) Timesulin pen cap Echo pen (Novo Nordisk) InPen Esysta smart pen Decision Support Tools Apps to help with insulin dosing calculations, optimization of pump setting For both health care providers and patients
25 ARTIFICIAL PANCREAS A Decade of Progress in AP Systems Veo-worldwide 640G Australia, Denmark UK USA soon 24
26 Medtronic 670G Hybrid Closed-Loop World 1 st Hybrid Closed Loop AP System Indications for 14+ years old Pediatric study underway Contra-indication: <7 year old, or <8 units of insulin/day Hybrid closed loop = automated basal rates Still need to bolus for meals Take care with Intense exercise, corrections for Stress Response etc Uses new Guardian CGM (AKA Enlite 3), 7 days use, 2 cals/day BS Target is fixed at 120 or 150mg/dl Does not include any Share type ability Pricing comparable to 630G ($7-8,000) 25
27 PATHWAYS TO ARTIFICIAL PANCREAS SYSTEMS AP Systems are coming Commercialization MDT: Hybrid CL: 2017 Bigfoot Biomedical: Hybrid CL Type Zero: Hybrid CL Beta Bionics: Dual-hormone Inreda: Dual-hormone Tandem Insulet SAG Roche The Plan for a World without T1D 26
28 Trials this year! Accelerating Progress 27
29 Currently Available Pumps Mostly sensor augmented pumps Tandem Roche Medtronic Insulet OmniPod (Patch Pump)
30 THE FUTURE OF JDRF ARTIFICIAL PANCREAS Three Goals for AP Systems 29
31 ARTIFICIAL PANCREAS Enhancing Glucose Control Additional inputs Faster insulins & other drugs Advanced algorithms 30
32 ARTIFICIAL PANCREAS Reducing Burden Advanced infusion sets Extended wear Integrated CGM Increased automation Miniaturization 31
33 ARTIFICIAL PANCREAS Expanding Access and Adoption Targeted subpopulations Barriers to adoption Open-protocol AP systems 32
34 Accelerating Progress 33
35 Accelerating Progress 34
36 BUILDING OUT LANDSCAPE FOR 2ND & 3RD GENERATION AP SYSTEMS Reduce Burden: Smaller Form Factor, Longer Wear RECENTLY FUNDED Making 1 st Gen AP work Better Longer Wear Infusion Sets 2 nd Gen Smaller Systems Concentrated insulin, miniature pumps, single port CGM/Infusion set 3 rd Gen Near Full Automation Fully Implantable systems may be a way to achieve near full automation & convenience Novel pumps/catheters, catheter failure
37 BUILDING OUT LANDSCAPE FOR 2ND & 3RD GENERATION AP SYSTEMS Reduce Burden: Smaller Form Factor, Longer Wear RECENTLY FUNDED Additional Signals for Gen 2-3 AP Identify other signals to inform AP algorithms Detection of onset, type, and duration of exercise, stress, sleep Reduce burden and improve outcomes User Centric AP systems Encourage Industry to Innovate and develop smaller, more convenient AP systems e.g. Integrated CGM/Patch pump e.g. Flexible, thin, bandage-like pump e.g. Integrated sensing and infusion e.g. Less invasive sensing (sinlge-port)
38 ARTIFICIAL PANCREAS Paving the Way for Open-Protocol AP Systems JDRF launched a new initiative that will support the development of open-protocol systems enabling artificial pancreas (AP) technology Funding via RFA Working with key stakeholders to establish clear regulatory and legal frameworks Initiative aims to advance AP technology and user friendliness and ensure its accessibility to a wider group of people with diabetes Encouraging interoperability among diabetes devices Harnessing the innovative spirit of the user-driven, do-it-yourself (DIY) community Will enable users of AP devices to achieve better glucose outcomes with an improved experience, in a way that works best for them 37
39 THANK YOU! QUESTIONS? 38
JDRF RESEARCH UPDATE. Daniel Finan, Ph.D. Research Director
JDRF RESEARCH UPDATE Daniel Finan, Ph.D. Research Director March 10, 2018 PRESENTER Daniel Finan Biomedical engineer B.S. Chemical Engineering University of Colorado, 2003 Ph.D. Chemical Engineering UC
More informationWhen Will CGM Replace SMBG? Roy W. Beck, MD, PhD. JAEB Center for Health Research Tampa, Florida
When Will CGM Replace SMBG? Roy W. Beck, MD, PhD JAEB Center for Health Research Tampa, Florida Financial Disclosures Dr. Beck does not have any personal conflicts of interest His employer, the JAEB Center
More informationCowen Investor Conference March confidently live life with ease
Cowen Investor Conference March 2018 confidently live life with ease Forward-Looking Statements This presentation contains certain forward-looking statements that involve risks and uncertainties that could
More informationDiabetes Technology Update. Sarah Konigsberg, MD Diabetes & Endocrine Assoc. April 7, 2018
Diabetes Technology Update Sarah Konigsberg, MD Diabetes & Endocrine Assoc. April 7, 2018 Disclosures None No future technologies are FDA approved Continuous Glucose Monitors Continuous Glucose Monitors
More informationThe Realities of Technology in Type 1 Diabetes
The Realities of Technology in Type 1 Diabetes May 6, 2017 Rosanna Fiallo-scharer, MD Margaret Frederick, RN Disclosures I have no conflicts of interest to disclose I will discuss some unapproved treatments
More informationUpdate on Diabetes Technology
Update on Diabetes Technology Andrew Ahmann, MD Professor of Medicine Director, Harold Schnitzer Diabetes Health Center OHSU Objectives: Recognize the growing role of technology in assisting patients and
More informationOBJECTIVES THE PAST INNOVATIVE TECHNOLOGY & DIABETES DIABETES MIS MANAGEMENT IMPROVEMENTS IN DIABETES MANAGEMENT
OBJECTIVES INNOVATIVE TECHNOLOGY & DIABETES TRISHA PORRETTI, RN, BSN, CDE PWD FOR 25 YEARS Identify important safety features and differences of 3 Continuous Glucose Monitoring (CGM) systems Identify important
More informationCGM and Closing The Loop
CGM and Closing The Loop Dualities Research: Helmsely Charitable Trust, ADA, JDRF, NIDDK Consulting: Abbott Diabetes Care, Roche, Intarcia, Valeritas, Adocia, Big Foot Like With Pumps, We ve Come A Long
More informationNEW TECHNOLOGIES FOR MANAGING DIABETES ANGELA THOMPSON DNP, FNP-C, BC-ADM, CDE, FAANP
NEW TECHNOLOGIES FOR MANAGING DIABETES ANGELA THOMPSON DNP, FNP-C, BC-ADM, CDE, FAANP No commercial support or sponsorship was received for this project I have nothing to disclose OBJECTIVES Identify at
More informationInsulin Pumps and Continuous Glucose Sensors- Embracing Technology. Susan Cavalier, BS, RN, CDE Manager, Diabetes Educator Sanford Diabetes Education
Insulin Pumps and Continuous Glucose Sensors- Embracing Technology Susan Cavalier, BS, RN, CDE Manager, Diabetes Educator Sanford Diabetes Education Diabetes Management Tools in 1974 Insulin pump history
More informationFuture Direction of Artificial Pancreas. Roy W. Beck, MD, PhD. JAEB Center for Health Research Tampa, Florida
Future Direction of Artificial Pancreas Roy W. Beck, MD, PhD JAEB Center for Health Research Tampa, Florida Financial Disclosures Dr. Beck does not have any personal conflicts of interest His employer,
More informationDIABETES & ENDOCRINE DIABETES TECHNOLOGY: HOW TO STAY CURRENT WITH ONGOING TECHNOLOGY ADVANCEMENT
DIABETES TECHNOLOGY: HOW TO STAY CURRENT WITH ONGOING TECHNOLOGY ADVANCEMENT Min-Jye Chen, MD Endocrinology Diabetes Management of the School-Aged Child Provided by Texas Children s Hospital Provider #18-267764-A
More informationAdvances in Technology in the Treatment of Diabetes Mellitus 2017 How far have we come-how far are we going? Is there a final frontier?
Advances in Technology in the Treatment of Diabetes Mellitus 2017 How far have we come-how far are we going? Is there a final frontier? Alan B Schorr DO FAAIM FACE www.sugardoc.com abs@sugardoc.com Disclosures
More informationJanuary 2017 Investor Presentation. confidently live life with ease
January 2017 Investor Presentation confidently live life with ease Forward-Looking Statements This presentation contains certain forward-looking statements that involve risks and uncertainties that could
More informationSubject Index. Breastfeeding, self-monitoring of blood glucose 56
Subject Index Animas Vibe 86, 130 Artificial pancreas clinical studies inpatient studies 175 180 outpatient studies outcome assessment 182, 183 technology 180, 181 telemedicine 182 components glucose sensor
More informationControl of Glycemic Variability for Reducing Hypoglycemia Jae Hyeon Kim
Control of Glycemic Variability for Reducing Hypoglycemia Jae Hyeon Kim Division of Endocrinology and Metabolism, Samsung Medical Center, Sungkyunkwan University School of Medicine Conflict of interest
More informationPeople with type 1 diabetes and Do It Yourself (DIY) technology solutions ABOUT THIS POSITION STATEMENT
Position Statement People with type 1 diabetes and Do It Yourself (DIY) technology solutions ABOUT THIS POSITION STATEMENT Diabetes Australia believes that people with diabetes should have choice and access
More informationAbbott FreeStyle Libre Pro System
Professional CGM Abbott FreeStyle Libre Pro Reader Kit includes: Reader, USB cable, interactive tutorial on USB, and power adapter, user s manual, Quick Start Guide, Quick Reference Guide Kit includes:
More informationToday s Goals 10/6/2017. New Frontiers in Diabetes Technology. Disclosures
New Frontiers in Diabetes Technology Marie E. McDonnell, MD Director, Brigham and Women's Diabetes Program Division of Endocrinology, Diabetes and Hypertension Brigham and Women s Hospital Today s Goals
More informationAdvances Towards the Bionic Pancreas.
Advances Towards the Bionic Pancreas. Ron Brazg MD, FACE Rainier Clinical Research Center Renton, WA DISCLOSURES Rainier Clinical Research Center is an independent research facility not directly affiliated
More informationNEWS BRIEFING Advances in Technology. moderated by: Irl Hirsch, MD University of Washington Medical Center
NEWS BRIEFING Advances in Technology moderated by: Irl Hirsch, MD University of Washington Medical Center 1 EMBARGO POLICY All recordings are for personal use only and not for rebroadcast online or in
More informationCanaccord Growth Conference August confidently live life with ease
Canaccord Growth Conference August 2018 confidently live life with ease Forward-Looking Statements This presentation contains forward-looking statements that are not purely historical regarding Senseonics
More informationUpdates in Diabetes Technology
Updates in Diabetes Technology Jessica Kirk, MSN, RN, CPN, CDE Nurse Manager, Endo ECHO No disclosures Disclosures 1 Objectives Distinguish patients appropriate for continuous glucose monitoring and insulin
More informationDiabetes II Insulin pumps; Continuous glucose monitoring system (CGMS) Ernest Asamoah, MD FACE FACP FRCP (Lond)
Diabetes II Insulin pumps; Continuous glucose monitoring system (CGMS) Ernest Asamoah, MD FACE FACP FRCP (Lond) 9501366-011 20110401 Objectives Understand the need for insulin pumps and CGMS in managing
More informationObjectives. The Problem. We ve come a LONG way, Innovations in Diabetes Care and Management. Barbara Walz, RN, BSN, CDE April 26, 2018
Objectives Innovations in Diabetes Care and Management Barbara Walz, RN, BSN, CDE April 26, 2018 1. Briefly discuss the history of diabetes management over the past 100 years 2. Describe the impact of
More informationTechnology in Diabetes Management Irl B. Hirsch, MD University of Washington
Technology in Diabetes Management 2016 Irl B. Hirsch, MD University of Washington Dualities Research: Helmsley Charitable Trust, JDRF, ADA, NIDDK, CDC Consulting: Abbott, Roche, Intarcia Raise Your Hand
More informationFlash Glucose Monitoring & Implantable Sensors
Flash Glucose Monitoring & Implantable Sensors Timothy Bailey, MD, FACE, CPI President & CEO, AMCR Institute Clinical Associate Professor, UCSD School of Medicine Disclosures Research Support: Abbott,
More informationDiabetes Technology in Irl B. Hirsch, MD University of Washington School of Medicine Seattle, WA
Diabetes Technology in 2018 Irl B. Hirsch, MD University of Washington School of Medicine Seattle, WA Dualities Research: Medtronic Diabetes Consulting: Abbott Diabetes Care, BD, Bigfoot, Roche Let s First
More informationDexcom Current and Future Technology Innovations. Jorge Valdes Chief Technical Officer
Dexcom Current and Future Technology Innovations 2015 Jorge Valdes Chief Technical Officer G5 App Sensor (Same as G4) Indicated for adults and children down to Age 2 years Tiny insertion needle (26Ga)
More informationDiabetes and Technology. Saturday, September 9, 2017 Aimee G sell, APRN, ANP-C, CDE
Diabetes and Technology Saturday, September 9, 2017 Aimee G sell, APRN, ANP-C, CDE Disclosure Speaker s Bureau: Janssan Pharmaceuticals Current Technology V-Go by Valeritas Continuous Sensors (personal
More informationNon-Invasive Glucose Monitoring. Kevin Walls April 12, :30 PM-7:30 PM.
Non-Invasive Glucose Monitoring Kevin Walls April 12, 2018 6:30 PM-7:30 PM. Technology is evolving Technology is evolving at such a rapid rate it s hard to keep up. Imagine living a healthier life without
More informationAbbott FreeStyle Libre Pro System
, the Professional CGM Abbott FreeStyle Libre Pro Reader Kit includes: Reader, USB cable, interactive tutorial on USB, and power adapter, user s manual, Quick Start Guide, Quick Reference Guide Kit includes:
More informationconfidently live life with ease Management Presentation
confidently live life with ease Management Presentation 1 Forward-Looking Statements This presentation contains certain forward-looking statements that involve risks and uncertainties that could cause
More informationMEDICAL POLICY Continuous Glucose Monitoring Systems and Insulin Pumps
POLICY: PG0177 ORIGINAL EFFECTIVE: 12/01/08 LAST REVIEW: 07/10/18 MEDICAL POLICY Continuous Glucose Monitoring Systems and Insulin Pumps GUIDELINES This policy does not certify benefits or authorization
More informationMEDICAL POLICY Continuous Glucose Monitoring Systems and Insulin Pumps
POLICY: PG0177 ORIGINAL EFFECTIVE: 12/01/08 LAST REVIEW: 05/24/18 MEDICAL POLICY Continuous Glucose Monitoring Systems and Insulin Pumps GUIDELINES This policy does not certify benefits or authorization
More informationContinuous Glucose Monitors for Diabetes Management
Continuous Glucose Monitors for Diabetes Management Ryan Huang, DO PGY II, Sonia Garcia-Jayne, DO PGY II Mandeep Gill, DO PGY I, Justin Leeka, DO, PGY I, Catherine Nguyen OMS IV Family Medicine Residency,
More information1. Continuous Glucose Monitoring
1. Continuous Glucose Monitoring 1. Physiology of interstitial fluid glucose 2. Comparison of CGM and self-monitored blood glucose (SMBG) data 3. Insulin dosing indication in BGM vs. CGM & the FDA 4. Protection
More informationMEDICAL POLICY Continuous Glucose Monitoring Systems and Insulin Pumps
POLICY: PG0177 ORIGINAL EFFECTIVE: 12/01/08 LAST REVIEW: 02/13/18 MEDICAL POLICY Continuous Glucose Monitoring Systems and Insulin Pumps GUIDELINES This policy does not certify benefits or authorization
More informationAnnual Stockholder Meeting May 30, confidently live life with ease
Annual Stockholder Meeting May 30, 2018 confidently live life with ease Forward-Looking Statements This presentation contains certain forward-looking statements that involve risks and uncertainties that
More informationThe next five years in diabetes technology: closed-loop systems
The next five years in diabetes technology: closed-loop systems J. H. (Hans) DeVries Academic Medical Center at the University of Amsterd, the Netherlands Keystone, CO, 19 July 2013 Disclosure AP@home,
More informationCONTINUOUS OR INTERMITTENT GLUCOSE MONITORING IN INTERSTITIAL FLUID
FLUID Non-Discrimination Statement and Multi-Language Interpreter Services information are located at the end of this document. Coverage for services, procedures, medical devices and drugs are dependent
More informationThe Growing Future of Diabetes: Insulin Pump Therapy in Type 1 and 2 Diabetes
The Growing Future of Diabetes: Insulin Pump Therapy in Type 1 and 2 Diabetes Sarah Dombrowski, PharmD, BCACP Pennsylvania Pharmacists Association 10/20/18 1 Objectives At the completion of this activity,
More information1 Dexcom G4 Platinum User Guide May 2012
1 Dexcom G4 Platinum User Guide May 2012 Page 1. Dexcom G4 PLATINUM Continuous Glucose Monitoring System. CE marked for use in 1Dexcom G4 User Guide, May 2012. LBL-011277 Rev04. color display. Dexcom G4
More informationAdvances in Diabetes Care Technologies
1979 Advances in Diabetes Care Technologies 2015 Introduction Roughly 20% - 30% of patients with T1DM and fewer than 1% of insulin-treated patients with T2DM use an insulin pump In 2007, the US FDA estimated
More informationFederal Initiatives in Smart Communities and the Internet of Things
Federal Initiatives in Smart Communities and the Internet of Things Vinay M. Pai (Acting) Division Director Division of Health Information Technology National Institute of Biomedical Imaging and Bioengineering
More informationJDRF Perspective on Closed Loop
JDRF Perspective on Closed Loop Aaron J. Kowalski, Ph.D. Assistant Vice President Treatment Therapies Juvenile Diabetes Research Foundation International 1 Presenter Disclosure Aaron Kowalski Disclosed
More informationPredicts and helps prevent lows with. zero fingersticks NOW FEATURING BASAL-IQ TECHNOLOGY
Predicts and helps prevent lows with * zero fingersticks NOW FEATURING BASAL-IQ TECHNOLOGY Basal-IQ Technology is not a substitute for active self-management of your diabetes. Please see back cover for
More informationCAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS Annual Meeting HILTON HEAD ISLAND FRIDAY PRESENTATION
CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting HILTON HEAD ISLAND FRIDAY PRESENTATION September 9-11, 2016 ~ Sonesta Resort ~ Hilton Head Island, SC This continuing
More informationGlucometers Gastrostomy Tubes Nasogastric Tubes Insulin pumps Continuous Glucose monitoring system Closed Loop Smart phones/tablets
Devices Glucometers Gastrostomy Tubes Nasogastric Tubes Insulin pumps Continuous Glucose monitoring system Closed Loop Smart phones/tablets Accuracy Glucometers The ISO (International Organization for
More informationACCELERATING PROGRESS. Aaron J. Kowalski Ph.D. JDRF Chief Mission Officer
ACCELERATING PROGRESS Aaron J. Kowalski Ph.D. JDRF Chief Mission Officer March 11, 2017 OUR VISION A W RLD WITHOUT TYPE 1 DIABETES Accelerating Progress 2 OUR PURPOSE JDRF was Founded by Families Driven
More informationAdvances in Diabetes Care Technologies
1979 Advances in Diabetes Care Technologies 2015 Introduction Insulin pump use: ~ 20% - 30% of patients with T1DM < 1% of insulin-treated patients with T2DM 2007 FDA estimates ~375,000 insulin pumps for
More information- Non-invasive - Mobile; collect data continuously at anywhere and any time - Used outside clinical setting
Background Advances in medical technologies are increasing remote patient monitoring programs. These technologies enable healthcare professionals to monitor the health status of patients outside clinical
More informationUvA-DARE (Digital Academic Repository) The artificial pancreas Kropff, J. Link to publication
UvA-DARE (Digital Academic Repository) The artificial pancreas Kropff, J. Link to publication Citation for published version (APA): Kropff, J. (2017). The artificial pancreas: From logic to life General
More informationAdvances in Diabetes Care Technologies
Advances in Diabetes Care Technologies 1979 2015 Introduction Roughly 20% to 30% of patients with T1DM and fewer than 1% of insulin-treated patients with T2DM use an insulin pump In 2007, the U.S. FDA
More information10:20 AM March 5, B 100% 235 u. 124 mg/dl 3 HRS INSULIN ON BOARD:
DEXCOM G5 MOBILE CGM COMPATIBLE B 100% 235 u INSULIN ON BOARD: OPTIONS 10:20 AM March 5, 2017 400 350 300 250 200 150 100 50 1.1 u 1:09 hrs BOLUS 124 mg/dl 3 HRS The pump that gets updated, not outdated.
More informationThe Dual Hormonal Artificial Pancreas in Diabetes Management. Medical Innovation Day Challenge
The Dual Hormonal Artificial Pancreas in Diabetes Management Medical Innovation Day Challenge 1 Background for the challenge A paradigm shift in treating diabetes Zealand Pharma is a Danish biotech company
More informationDoes Technology helps adolescents with type 1 diabetes in fasting Ramadan?
Does Technology helps adolescents with type 1 diabetes in fasting Ramadan? Abdulmoein Al-Agha, FRCPCH Professor of Paediatric Endocrinology, King Abdulaziz University Hospital, http://aagha.kau.edu.sa
More informationMore Than 1 Year of Hybrid Closed Loop in Pediatrics. Gregory P. Forlenza, MD Assistant Professor Barbara Davis Center
More Than 1 Year of Hybrid Closed Loop in Pediatrics Gregory P. Forlenza, MD Assistant Professor Barbara Davis Center Disclosure Dr. Forlenza has served as a consultant for Abbott Diabetes Care and conducts
More informationTechnology in Diabetes Care: Emerging Level
Technology in Diabetes Care: Emerging Level Charlotte Parsons ARNP, CDE Christine Fisher, RD, CD, CDE, CPT WADE April 26, 2019 Disclosures to Participants Notice of Requirements for Successful Completion:
More informationAdvances in Diabetes Technology Part II: Analysis of Diabetes Self Management Devices and Support Tools
Advances in Diabetes Technology Part II: Analysis of Diabetes Self Management Devices and Support Tools Jennifer Trujillo, PharmD, FCCP, BCPS, CDE, BC ADM Associate Professor University of Colorado School
More informationThe BEST Glycemic Control Tool. Yanhaijin
The BEST Glycemic Control Tool Yanhaijin 11-02-2014 DIABETES IS A GLOBAL EPIDEMIC -382 million people w/w have diabetes. (2012/IDF) -592 million people w/w will have diabetes. (2030/IDF) -29.1 million
More informationCOMPANY OVERVIEW. April 26, 2018
COMPANY OVERVIEW April 26, 2018 SAFE HARBOR & NON-GAAP FINANCIAL MEASURES Forward Looking Statements Certain statements in this presentation constitute forward-looking statements, including, without limitation,
More informationCompany Overview February 26, 2019
Company Overview February 26, 2019 SAFE HARBOR Cautionary Note Regarding Forward-Looking Statements Certain statements in this presentation constitute forward-looking statements, including, without limitation,
More informationContinuous Glucose Monitoring
Continuous Glucose Monitoring Information about fully-subsidised continuous glucose monitoring for children and young people with type 1 diabetes Continuous glucose monitoring (CGM) can help in managing
More informationDIABETES TECHNOLOGY: ENDLESS CHOICES FOR HEALTHY MANAGEMENT
DIABETES TECHNOLOGY: ENDLESS CHOICES FOR HEALTHY MANAGEMENT MAKING THE MOST OF MODERN DIABETES TREATMENTS & TECHNOLOGIES JENNIFER C. SMITH RD, LD, CDE DIRECTOR OF LIFESTYLE AND NUTRITION INTEGRATED DIABETES
More informationTABLE OF CONTENTS. HLC102A - Continuous Glucose Monitoring (CGM): Technologies and Global Markets
TABLE OF CONTENTS CHAPTER 1 INTRODUCTION 1 STUDY GOALS AND OBJECTIVES 1 REASONS FOR DOING THIS STUDY 1 CONTRIBUTIONS TO THE STUDY AND INTENDED AUDIENCE 1 SCOPE AND FORMAT 1 METHODOLOGY AND INFORMATION
More informationCorporate Medical Policy
Corporate Medical Policy Continuous Monitoring of Glucose in the Interstitial Fluid File Name: Origination: Last CAP Review: Next CAP Review: Last Review: continuous_monitoring_of_glucose_in_the_interstitial_fluid
More informationDr Sander Zwart MD, FACP, ECNU Arizona-AACE 2016 Annual Meeting
Dr Sander Zwart MD, FACP, ECNU Arizona-AACE 2016 Annual Meeting Disclaimers None Except products and software discussed are all proprietary, so if I mention a brand product it is because there is no other
More informationC o n n e c t e d I n s u l i n D e l i v e r y S y s t e m
Technology Innovation Alert C o n n e c t e d I n s u l i n D e l i v e r y S y s t e m 6 July 12 July, 2018 1 4 0 0 Start ups Companies Universities Individuals Interesting Innovation Compliance with
More informationEmerging Automated Insulin Delivery Systems
Emerging Automated Insulin Delivery Systems Richard M. Bergenstal, MD International Diabetes Center Park Nicollet & HealthPartners Minneapolis, MN Presenter Name 1 Dualities: Richard M. Bergenstal, MD
More informationThe artificial pancreas: the next step in connectivity and digital treatment of type 1 diabetes
The artificial pancreas: the next step in connectivity and digital treatment of type 1 diabetes Roman Hovorka PhD FMedSci University of Cambridge, UK Duality of interest declaration Advisory Panel: Research
More informationContinuous Glucose Monitoring (CGM)
Continuous Glucose Monitoring (CGM) Background Info A1c Average glucose levels over previous 2-3 months Currently remains gold standard for determining control Indicator of risk for development of complications
More informationCONTINUOUS GLUCOSE MONITORING SOLUTIONS Provided by Roche Diabetes Care
CONTINUOUS GLUCOSE MONITORING SOLUTIONS Provided by Roche Diabetes Care More confidence for your patients 03 GIVING YOU THE CHOICE CGM solutions provided by Roche Diabetes Care Welcome to a world of new
More informationCOMPANY OVERVIEW. July 30, 2018
COMPANY OVERVIEW July 30, 2018 SAFE HARBOR & NON-GAAP FINANCIAL MEASURES Forward Looking Statements Certain statements in this presentation constitute forward-looking statements, including, without limitation,
More informationHybrid Closed Loop Status & Practical Challenges in Implementation
Hybrid Closed Loop Status & Practical Challenges in Implementation Bruce Buckingham, MD Buckingham@Stanford.edu Professor of Pediatric Endocrinology Stanford School of Medicine Conflict of Interests Company
More informationThis is a licensed product of Ken Research and should not be copied
1 TABLE OF CONTENTS 1. The US Diabetes Care Devices Market Introduction 1.1. What is Diabetes and it s Types? 2. The US Diabetes Care Devices Market Size, 2007-2013 3. The US Diabetes Care Devices Market
More informationADA 2018 JUN 25, 2018 ORLANDO, FLORIDA
ADA 2018 JUN 25, 2018 ORLANDO, FLORIDA FORWARD LOOKING STATEMENTS This presentation contains forward-looking statements. They are based on current assumptions and expectations that involve uncertainties
More informationAnimas Vibe System World-class insulin pumping meets world-class CGM*
Animas Vibe System World-class insulin pumping meets world-class CGM* Fully integrated with Dexcom G4 PLATINUM CGM* *Continuous glucose monitoring. My Animas pump has really put me in the driver s seat
More informationQuick Reference Guide. Sensor Smart Transmitter Mobile App
Quick Reference Guide Sensor Smart Transmitter Mobile App Refer to the Eversense CGM User Guide for more detailed information. For a Spanish version of the User Guide and Quick Reference Guide, please
More informationINVESTOR DAY JUN 5, 2018 NEW YORK CITY
INVESTOR DAY JUN 5, 2018 NEW YORK CITY HOOMAN HAKAMI EVP AND GROUP PRESIDENT DIABETES GROUP FORWARD LOOKING STATEMENTS This presentation contains forward-looking statements. They are based on current assumptions
More informationQUESTION 4. WHAT CLINICAL DATA ARE CURRENTLY AVAILABLE TO SUPPORT EXPANDED CGM COVERAGE BY PAYERS AS PERTAINS TO QUESTIONS 1 AND 3?
500 1 QUESTION 4. WHAT CLINICAL DATA ARE CURRENTLY AVAILABLE TO SUPPORT EXPANDED CGM COVERAGE BY PAYERS AS PERTAINS TO QUESTIONS 1 AND 3? WHAT ADDITIONAL DATA ARE NEEDED? AACE/ACE CGM Consensus Conference:
More informationApproved by: Integrated Health Quality Management Subcommittee Effective Date: Department of Origin: Integrated Healthcare Services.
Reference #: MC/L008 Page: 1 of 8 PRODUCT APPLICATION: PreferredOne Community Health Plan (PCHP) PreferredOne Administrative Services, Inc. (PAS) ERISA PreferredOne Administrative Services, Inc. (PAS)
More informationDiabetes Update 2017: Advancement in glucose monitoring & insulin Delivery
Diabetes Update 2017: Advancement in glucose monitoring & insulin Delivery Abdulmoein Eid Al-Agha, MBBS, DCH, CABP, FRCPCH Professor of Pediatric Endocrinology, King Abdulaziz University Hospital Highlights
More informationDiabetes through my eyes. Rick Mauseth, M.D. W.A.D.E. April 2013
Diabetes through my eyes Rick Mauseth, M.D. W.A.D.E. April 2013 Ant hills Total Available Glucose utilized Two drops of urine in test tube Add 10 drops of water Added tablet Foamed and got hot Compared
More informationClinical News and Innovation in Type 1 Diabetes and Technology. Parth Narendran University Hospitals Birmingham
Clinical News and Innovation in Type 1 Diabetes and Technology Parth Narendran University Hospitals Birmingham Adjunctive therapy to insulin Accurate diagnosis of T1D Early intensive treatment Technology
More informationMonitoring of Blood Glucose Level
University of Zagreb Faculty of Electrical Engineering and Computing Biomedical instrumentation Monitoring of Blood Glucose Level Biomedical instrumentation 1/17 Outline Introduction Principles of Blood
More informationComparative table of insulin pumps
Comparative table of insulin pumps Pumps reviewed: insight (Roche Veo 640G Mylife OmniPod Mylife S () The first stop for professional medicines advice www.sps.nhs.uk Authored May 2018 Insight OmniPod S
More informationMaking the Most of Continuous Glucose Monitoring
Making the Most of Continuous Glucose Monitoring Gary Scheiner MS, CDE Owner & Clinical Director Integrated Diabetes Services LLC Wynnewood, PA AADE 2014 Diabetes Educator of the Year gary@integrateddiabetes.com
More informationAlternative Devices for Taking Insulin
Alternative Devices for Taking Insulin Many people with diabetes must take insulin to manage their disease. Most people who take insulin use a needle and syringe to inject insulin just under the skin.
More informationBetter Diagnostics for Life
NASDAQ: NMRD Better Diagnostics for Life Interim Clinical Presentation sugarbeat 12 th September 2018 A Prospective Single Centre Evaluation of the Accuracy and safety of the sugarbeat Non-invasive Continuous
More informationArtificial Pancreas Device System (APDS)
Medical Policy Manual Durable Medical Equipment, Policy No. 77 Artificial Pancreas Device System (APDS) Next Review: October 2019 Last Review: October 2018 Effective: November 1, 2018 IMPORTANT REMINDER
More informationUsing and Interpreting Diabetes Data. Irl B. Hirsch, MD University of Washington
Using and Interpreting Diabetes Data Irl B. Hirsch, MD University of Washington Dualities Research: Helmsely Charitable Trust, ADA, JDRF, NIDDK Consulting: Abbott Diabetes Care, Roche, Intarcia, Valeritas,
More informationPump and Sensor Data Interpretation. Irl B. Hirsch, MD University of Washington School of Medicine
Pump and Sensor Data Interpretation Irl B. Hirsch, MD University of Washington School of Medicine Dualities Research: Medtronic Diabetes Consulting: Abbott Diabetes Care, BD, Bigfoot, Roche Raise Your
More informationFAQs for HCP segment New Instructions for Dexcom G5 Mobile Continuous Glucose Monitoring (CGM) System Non-Adjunctive Indication
FAQs for HCP segment New Instructions for Dexcom G5 Mobile Continuous Glucose Monitoring (CGM) System Non-Adjunctive Indication Q1. The Dexcom G5 Mobile System is the first CGM System to receive FDA approval
More informationNDSS Helpline
Continuous GLUCOSE MONITORING A guide to using CGM for children and young people with type 1 diabetes NDSS Helpline 1300 136 588 ndss.com.au The National Diabetes Services Scheme is an initiative of the
More informationNewsletter May, Recent advances in. Life Sciences
Newsletter May, 2018 Recent advances in Life Sciences VOLUME 1/ISSUE 2 WWW.MAXVAL.COM IN THIS ISSUE: 01 Base Editors in CRISPR This article presents a base editing approach to expand the scope and efficiency
More informationDiabetes Management: Current High Tech Innovations
Diabetes Management: Current High Tech Innovations How Far We ve Come in the Last 40 Years William V. Tamborlane, MD Department of Pediatrics Yale School of Medicine Disclosures I am a consultant for:
More informationBetter Diagnostics for Life
NASDAQ: NMRD Better Diagnostics for Life Corporate Presentation November 2018 Forward-Looking Statement This presentation includes forward-looking statements that are subject to many risks and uncertainties.
More informationWHEN YOUR PANCREAS IS NOT A HAPPY CAMPER A PRESENTATION ON DIABETES MANAGEMENT IN THE CAMP SETTING AMANDA COSCHI, BSCN, RN, CDE
WHEN YOUR PANCREAS IS NOT A HAPPY CAMPER A PRESENTATION ON DIABETES MANAGEMENT IN THE CAMP SETTING AMANDA COSCHI, BSCN, RN, CDE MAY 5, 2018 OBJECTIVES Strong understanding of diabetes and its management
More information