Dosimetric Effects of Using Generalized Equivalent Uniform Dose (geud) in Plan Optimization
|
|
- Beatrice Griffith
- 5 years ago
- Views:
Transcription
1 Dosimetric Effects of Using Generalized Equivalent Uniform Dose (geud) in Plan Optimization Ontida Apinorasethkul, MS, CMD AAMD Indianapolis June 14, 2017
2 Disclaimer This presentation is not sponsored by any vendor nor is it endorsing one treatment planning system over another. The material presented is based on our planning experience. This talk is meant for educational purposes. 2
3 Overview What is geud? α values geud optimization Benefits and drawbacks Plan comparisons against dose volume- (DV) based objectives Prostate Whole pelvis Brain H&N Lung 3
4 What is geud? Generalized Equivalent Uniform Dose The dose that, if given uniformly to the entire organ, is believed to yield the same complication rate as the true dose distribution (QUANTEC) Accommodates the concept of serial and parallel organs Achieve same tumor response, lower normal tissue dose More non-uniform dose distribution Less dependent on the variability of patient s shapes and sizes Less trial and error when planning one case to another 4
5 What is geud? Eclipse 13.5 and newer New photon optimizer (PO) algorithm Supports biological optimization objectives Implement biological planning in daily treatment planning DV = biological response geud = estimates of the biological outcome IMRT and RA optimization Shift to a non-uniform target dose distribution? Organ motion Daily set up uncertainties Brachytherapy SRS/SBRT Simultaneous integrated boost 5
6 Workout analogy Goal: lose 5 pounds in 2 months Cardio only Weight training only Combinations? End result: Weight loss is equivalent to 5 pounds 6
7 geud optimization For tumors, the EUD represents the biologically equivalent dose which, if given uniformly, leads to the same cell kill in the tumor volume as the actual non-uniform IMRT dose-distribution. EUD = TG-166 7
8 α values geud is dependent on α value. Tissue-specific parameter that describes the volume effect of geud Defines where on the DVH the optimization is to be focused on Values range from -40 to +40, but can never be zero -40 to -1 = tumor range 1 = mean objective 1 to 40 = organs at risk range Low α values: parallel organs High α values: serial organs 8
9 α values TG-166 report 9
10 α values Quantec / Burman 1 0
11 geud optimization Target geud α of -40 to -1 Defines an exact Equivalent Uniform dose value Ex: PTV must receive 95% of dose. Similar to lower objective of DVbased optimization Lower geud α of -40 to -1 Defines the minimum Equivalent Uniform dose value Ex: PTV must receive at least 60 Gy. Works well on overlapping structures Varian 1 1
12 geud optimization Upper geud α of 40 to 1 Defines the maximum Equivalent Uniform Dose value Ex: Inner ear may receive no more than 25 Gy. Lower α value in the upper geud will affect majority of the DVH curve Higher α value in the upper geud will affect max dose of the DVH curve Varian 1 2
13 α values Different alpha values Same priority value 1 3
14 Benefits and drawbacks Typically lower normal tissue dose while maintaining tumor coverage geud objectives are generally used for organs at risk Instead of several upper objectives on multiple contours Smaller number of parameters used, larger space of solutions become available Less ambiguity in less number of objectives Limit max dose Lower mean dose Limited number of parameters controlled by user Details of dose distribution can t be fine tuned 1 4
15 geud optimization With our experience.. Using only geud objectives on target volumes could result in a highly non-uniform dose distribution Avoid target dose heterogeneities that would not be accepted in clinical plans Evaluate plans for non-uniform dose 1 5
16 geud optimization With our experience.. Use upper and lower objectives of DV-based optimization for a better control over target dose distribution geud works better on normal tissue optimizations 1 6
17 DV-based optimization objectives 1 7
18 geud based optimization objectives 1 8
19 Plan comparisons 1 9
20 Plan comparisons Research phase Same field parameters Arcs / collimator angles Field gantry DV-based optimization Multiple upper objectives on organs at risk Optimize on crop structures geud-based optimization PTV objectives - same as DV-based optimized plan Optimize on whole organs at risk structure One upper geud objective for each structure* α of 1, 20, or
21 Prostate plan DV-based objectives geud-based objectives 2 1
22 Prostate plan DV geud 2 2
23 Prostate plan DV geud 2 3
24 Prostate plan DV geud 2 4
25 Prostate plan Mean dose (cgy) DV geud Bladder Rectum
26 Prostate plan Mean dose (cgy) DV geud Femoral head_l Femoral head_r
27 Pelvis plan DV-based objectives 2 7
28 Pelvis plan geud-based objectives 2 8
29 Pelvis plan DV geud 2 9
30 Pelvis plan DV geud 3 0
31 Pelvis plan DV geud Dose max 109.5% Dose max 116.2% 3 1
32 Pelvis plan Mean dose (cgy) DV geud Small bowel Large bowel Rectum Bladder
33 Brain plan DV-based objectives 3 3
34 Brain plan geud-based objectives 3 4
35 Brain plan DV geud 3 5
36 Brain plan DV geud 3 6
37 Brain plan DV geud 3 7
38 Brain plan DV geud 3 8
39 Brain plan Organs DV geud Brainstem (max) Temporal lobe_l (mean)
40 H&N plan DV-based objectives 4 0
41 H&N plan geud-based objectives 4 1
42 H&N plan DV geud 4 2
43 H&N plan DV geud 4 3
44 H&N plan DV geud 4 4
45 H&N plan DV geud 4 5
46 H&N plan DV geud 4 6
47 H&N plan Max dose (cgy) DV geud Brainstem Cord Cord+5mm
48 H&N plan Mean dose (cgy) DV geud Oral cavity Larynx Constrictor
49 H&N plan Mean dose (cgy) DV geud Submandibular_L Parotid_L Parotid_R
50 Lung plan DV-based objectives geud-based objectives 5 0
51 Lung plan DV geud 5 1
52 Lung plan DV geud 5 2
53 Lung plan DV geud 5 3
54 Lung plan DV geud 5 4
55 Lung plan DV geud 5 5
56 Lung plan IMRT same fields Max dose (cgy) DV geud Brachial plexus_r Cord Cord+5mm
57 Summary With one iteration of optimization, geud optimized plan generally shows lower dose to organs at risk Fine tuning is still needed Higher global max In general, geud based optimization can help improve normal tissue sparing while maintaining the same or better target volume coverage 5 7
58 Summary Use radiobiological based model tools/algorithms to our benefits with caution Results in non-uniform target dose No one method is perfect More research needed of new function Use of geud on target volumes in the future 5 8
59 Acknowledgements Derek Dolney, PhD Akhil Tiwari, CMD Dimitris Mihailidis, PhD 5 9
60 6 0
Efficient SIB-IMRT planning of head & neck patients with Pinnacle 3 -DMPO
Investigations and research Efficient SIB-IMRT planning of head & neck patients with Pinnacle 3 -DMPO M. Kunze-Busch P. van Kollenburg Department of Radiation Oncology, Radboud University Nijmegen Medical
More informationIMRT Planning Basics AAMD Student Webinar
IMRT Planning Basics AAMD Student Webinar March 12, 2014 Karen Chin Snyder, MS Senior Associate Physicist Department of Radiation Oncology Disclosures The presenter has received speaker honoraria from
More informationRADIOBIOLOIGCALLY BASED TREATMENT PLANNING: THE NEXT FRONTIER. Teddy LaMaster, MS
RADIOBIOLOIGCALLY BASED TREATMENT PLANNING: THE NEXT FRONTIER Teddy LaMaster, MS RADIOBIOLOGY Radiobiology is the interaction between ionizing radiation and living things. Varies for different cells, organs,
More informationHead and Neck Treatment Planning: A Comparative Review of Static Field IMRT RapidArc TomoTherapy HD. Barbara Agrimson, BS RT(T)(R), CMD
Head and Neck Treatment Planning: A Comparative Review of Static Field IMRT RapidArc TomoTherapy HD Barbara Agrimson, BS RT(T)(R), CMD Disclaimer This presentation will mention equipment by trade name.
More informationIMAT: intensity-modulated arc therapy
: intensity-modulated arc therapy M. Iori S. Maria Nuova Hospital, Medical Physics Department Reggio Emilia, Italy 1 Topics of the talk Rotational IMRT techniques: modalities & dedicated inverse-planning
More informationA Dosimetric Comparison of Whole-Lung Treatment Techniques. in the Pediatric Population
A Dosimetric Comparison of Whole-Lung Treatment Techniques in the Pediatric Population Corresponding Author: Christina L. Bosarge, B.S., R.T. (R) (T) Indiana University School of Medicine Department of
More informationRadiation Damage Comparison between Intensity Modulated Radiotherapy (IMRT) and Field-in-field (FIF) Technique In Breast Cancer Treatments
Radiation Damage Comparison between Intensity Modulated Radiotherapy () and Field-in-field (FIF) Technique In Breast Cancer Treatments Huisi Ai 1 and Hualin Zhang 2 1. Department of Radiation Oncology,
More informationSilvia Pella, PhD, DABR Brian Doozan, MS South Florida Radiation Oncology Florida Atlantic University Advanced Radiation Physics Boca Raton, Florida
American Association of Medical Dosimetrists 2015 Silvia Pella, PhD, DABR Brian Doozan, MS South Florida Radiation Oncology Florida Atlantic University Advanced Radiation Physics Boca Raton, Florida Most
More informationFeasibility of the partial-single arc technique in RapidArc planning for prostate cancer treatment
Chinese Journal of Cancer Original Article Feasibility of the partial-single arc technique in RapidArc planning for prostate cancer treatment Suresh Rana 1 and ChihYao Cheng 2 Abstract The volumetric modulated
More informationOutline. Contour quality control. Dosimetric impact of contouring errors and variability in Intensity Modulated Radiation Therapy (IMRT)
Dosimetric impact of contouring errors and variability in Intensity Modulated Radiation Therapy (IMRT) James Kavanaugh, MS DABR Department of Radiation Oncology Division of Medical Physics Outline Importance
More informationA guide to using multi-criteria optimization (MCO) for IMRT planning in RayStation
A guide to using multi-criteria optimization (MCO) for IMRT planning in RayStation By David Craft Massachusetts General Hospital, Department of Radiation Oncology Revised: August 30, 2011 Single Page Summary
More informationA treatment planning study comparing Elekta VMAT and fixed field IMRT using the varian treatment planning system eclipse
Peters et al. Radiation Oncology 2014, 9:153 RESEARCH Open Access A treatment planning study comparing Elekta VMAT and fixed field IMRT using the varian treatment planning system eclipse Samuel Peters
More informationRectal dose and toxicity dosimetric evaluation for various beam arrangements using pencil beam scanning protons with and without rectal spacers
Rectal dose and toxicity dosimetric evaluation for various beam arrangements using pencil beam scanning protons with and without rectal spacers 2015 MAC-AAPM Annual Meeting, Baltimore, MD Heeteak Chung,
More informationThe objective of this lecture is to integrate our knowledge of the differences between 2D and 3D planning and apply the same to various clinical
The objective of this lecture is to integrate our knowledge of the differences between 2D and 3D planning and apply the same to various clinical sites. The final aim will be to be able to make out these
More informationAutomated Plan Quality Check with Scripting. Rajesh Gutti, Ph.D. Clinical Medical Physicist
Automated Plan Quality Check with Scripting Rajesh Gutti, Ph.D. Clinical Medical Physicist Veera.Gutti@BSWHealth.org Outline Introduction - BSW Automation in Treatment planning Eclipse Scripting API Script
More information7/10/2015. Acknowledgments. Institution-specific TG-142? AAPM:Task Group-142. Failure-Mode & Effects Analysis
Acknowledgments Thanks to Saiful Huq for an illuminating conversation about the application of TG-100 Jennifer O Daniel, Ph.D. & Fang-Fang Yin, Ph.D. Duke University Medical Center Annual AAPM Meeting,
More informationMulti-Case Knowledge-Based IMRT Treatment Planning in Head and Neck Cancer. Shelby Mariah Grzetic. Graduate Program in Medical Physics Duke University
Multi-Case Knowledge-Based IMRT Treatment Planning in Head and Neck Cancer by Shelby Mariah Grzetic Graduate Program in Medical Physics Duke University Date: Approved: Joseph Y. Lo, Co-Supervisor Shiva
More informationVaginal Sparing with Volumetric Modulated Arc Therapy (VMAT) for Rectal Cancer. Scott Boulet BSc, RT(T)
Vaginal Sparing with Volumetric Modulated Arc Therapy (VMAT) for Rectal Cancer Scott Boulet BSc, RT(T) Outline Background Objectives Design Results Discussion Conclusion Acknowledgements Questions Background
More informationClinical Impact of Couch Top and Rails on IMRT and Arc Therapy
Texas Medical Center Library DigitalCommons@TMC UT GSBS Dissertations and Theses (Open Access) Graduate School of Biomedical Sciences 8-2011 Clinical Impact of Couch Top and Rails on IMRT and Arc Therapy
More informationRanking radiotherapy treatment plans: physical or biological objectives?
Ranking radiotherapy treatment plans: physical or biological objectives? Martin Ebert Department of Radiation Oncology, Sir Charles Gairdner Hospital, Western Australia, Australia Background. The ranking
More informationTreatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)
Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI) Tagreed AL-ALAWI Medical Physicist King Abdullah Medical City- Jeddah Aim 1. Simplify and standardize
More informationIMRT - the physician s eye-view. Cinzia Iotti Department of Radiation Oncology S.Maria Nuova Hospital Reggio Emilia
IMRT - the physician s eye-view Cinzia Iotti Department of Radiation Oncology S.Maria Nuova Hospital Reggio Emilia The goals of cancer therapy Local control Survival Functional status Quality of life Causes
More informationOriginal Article. Teyyiba Kanwal, Muhammad Khalid, Syed Ijaz Hussain Shah, Khawar Nadeem
Original Article Treatment Planning Evaluation of Sliding Window and Multiple Static Segments Technique in Intensity Modulated Radiotherapy for Different Beam Directions Teyyiba Kanwal, Muhammad Khalid,
More informationKnowledge-Based IMRT Treatment Planning for Prostate Cancer: Experience with 101. Cases from Duke Clinic. Deon Martina Dick
Knowledge-Based IMRT Treatment Planning for Prostate Cancer: Experience with 101 Cases from Duke Clinic by Deon Martina Dick Department of Medical Physics Duke University Date: Approved: Joseph Lo, Chair
More informationX. Allen Li BGRT. Biologically Based Treatment Planning. Biologically based treatment planning
Biologically Based Treatment Planning X. Allen Li AAPM Spring Clinical Meeting, March 20, 2012 Limitations of dose-volume based treatment planning DV metrics are merely surrogate measures of radiation
More informationMeasurement of Dose to Critical Structures Surrounding the Prostate from. Intensity-Modulated Radiation Therapy (IMRT) and Three Dimensional
Measurement of Dose to Critical Structures Surrounding the Prostate from Intensity-Modulated Radiation Therapy (IMRT) and Three Dimensional Conformal Radiation Therapy (3D-CRT); A Comparative Study Erik
More informationBiologically Based Treatment Planning X. Allen Li
Biologically Based Treatment Planning X. Allen Li AAPM Spring Clinical Meeting, March 20, 2012 Limitations of dose-volume based treatment planning DV metrics are merely surrogate measures of radiation
More informationProstate and Lymph Node VMAT Treatment Planning
Prostate and Lymph Node VMAT Treatment Planning Jess France, Alison McVey, Graham McVey, Jaap Vaarkamp 1 Presentation Outline Old planning method multi-phase New planning method single-phase Comparison
More informationRadiobiological Impact of Planning Techniques for Prostate Cancer in Terms of Tumor Control Probability and Normal Tissue Complication Probability
Original Article Radiobiological Impact of Planning Techniques for Prostate Cancer in Terms of Tumor Control Probability and Normal Tissue Complication Probability Rana S, Cheng CY Department of Medical
More informationRole of Belly Board Device in the Age of Intensity Modulated Radiotherapy for Pelvic Irradiation
Role of Belly Board Device in the Age of Intensity Modulated Radiotherapy for Pelvic Irradiation 2017 AAMD 42 nd Annual Meeting Neil C. Estabrook, MD 6 / 14 / 2017 7/5/2017 1 Conflicts of Interest None
More informationIt s All About Margins. Maaike Milder, Ph.D. Accuray Symposium April 21 st 2018
It s All About Margins Maaike Milder, Ph.D. Accuray Symposium April 21 st 2018 Why margins? The smaller the better! Short Introduction Erasmus MC has been using the CyberKnife Robotic Radiosurgery System
More informationOPTIMIZATION OF COLLIMATOR PARAMETERS TO REDUCE RECTAL DOSE IN INTENSITY-MODULATED PROSTATE TREATMENT PLANNING
Medical Dosimetry, Vol. 30, No. 4, pp. 205-212, 2005 Copyright 2005 American Association of Medical Dosimetrists Printed in the USA. All rights reserved 0958-3947/05/$ see front matter doi:10.1016/j.meddos.2005.06.002
More informationNumber of targets 1. Number of OARs 2. Total number of plans 22. Analyzed OAR structures. Feature Min Max Mean Std
VARIAN Model Analytics Model Name: Haris_PRO_Rez_Model_ Description FFF SingleArc Pläne (typ. PRO-Rezidiv) Dose prescriptions Gy (), 7 Gy (), 7 Gy (), Gy (), Gy () Model summary Number of targets Number
More informationEvaluation of Normal Tissue Complication Probability and Risk of Second Primary Cancer in Prostate Radiotherapy
Evaluation of Normal Tissue Complication Probability and Risk of Second Primary Cancer in Prostate Radiotherapy Rungdham Takam Thesis submitted for the degree of Doctor of Philosophy in The School of Chemistry
More informationMany vendors are beginning to allow couch motion during radiation delivery.
Dynamic Couch Motion Many vendors are beginning to allow couch motion during radiation delivery. Varian developer mode allows institutions to perform research using these types of treatments. Tomotherapy
More informationA VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM *
Romanian Reports in Physics, Vol. 66, No. 2, P. 401 410, 2014 A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM * M. D. SUDITU 1,2, D. ADAM 1,2, R. POPA 1,2, V. CIOCALTEI
More informationDosimetric Uncertainties and Normal Tissue Tolerance. Ellen D Yorke Memorial Sloan Kettering Cancer Center New York City
Dosimetric Uncertainties and Normal Tissue Tolerance Ellen D Yorke Memorial Sloan Kettering Cancer Center New York City Traditional accuracy/precision goal is to deliver external beam radiation therapy
More informationNormal tissue dose in pediatric VMAT Piotr Zygmanski
Normal tissue dose in pediatric VMAT Piotr Zygmanski Department of Radiation Oncology Brigham and Women s Hospital Radiation induced effects in children Risk of inducing 2 nd cancers higher than for adults
More informationThe bootstrap method to improve statistical analysis of dosimetric data for radiotherapy outcomes
The bootstrap method to improve statistical analysis of dosimetric data for radiotherapy outcomes Abdulhamid Chaikh1,2, Jean-Pierre Bresciani3,4, Jacques Balosso2,4 1Department of Radiation Oncology and
More informationPlan-Specific Correction Factors for Small- Volume Ion Chamber Dosimetry in Modulated Treatments on a Varian Trilogy
Plan-Specific Correction Factors for Small- Volume Ion Chamber Dosimetry in Modulated Treatments on a Varian Trilogy Vimal K. Desai, M.S. Under the supervision of Dr. Wesley Culberson NCCAAPM 2017 Fall
More informationMVCT Image. Robert Staton, PhD DABR. MD Anderson Cancer Center Orlando. ACMP Annual Meeting 2011
MVCT Image Guidance and QA Robert Staton, PhD DABR MD Anderson Cancer Center Orlando ACMP Annual Meeting 2011 Disclosures MDACCO has received grant funding from TomoTherapy, Inc. Overview TomoTherapy MVCT
More informationWill CyberKnife M6 Multileaf collimator offer advantages over IRIS collimator in prostate SBRT?
Will CyberKnife M6 Multileaf collimator offer advantages over collimator in prostate SBRT? Vindu Kathriarachchi Professional Science Master in Medical Physics Department of Physics, Florida Atlantic University,
More informationHybrid VMAT/IMRT Approach to Traditional Cranio-Spinal Irradiation (CSI): A Case Study on Planning Techniques and Delivery
Hybrid VMAT/IMRT Approach to Traditional Cranio-Spinal Irradiation (CSI): A Case Study on Planning Techniques and Delivery Catherine Cadieux, CMD June 13, 2017 The Ohio State University Comprehensive Cancer
More informationAshley Pyfferoen, MS, CMD. Gundersen Health Systems La Crosse, WI
Ashley Pyfferoen, MS, CMD Gundersen Health Systems La Crosse, WI 3 Radiation Oncologists 3 Physicists 2 Dosimetrists 9 Radiation Therapists o o o o o o o o o Brachial Plexus Anatomy Brachial Plexopathy
More informationJosh Howard CMD Upendra Parvathaneni MBBS, FRANZCR
Anatomic and Dosimetric Correlation in the Treatment of Advanced Larynx Cancer- When is the Brachial Plexus at Risk? Josh Howard CMD Upendra Parvathaneni MBBS, FRANZCR AAMD 39th Annual Meeting - Seattle
More informationLeila E. A. Nichol Royal Surrey County Hospital
2 nd UK and Ireland Dosimetry Check User Meeting Symposium Clatterbridge Cancer Centre, 24 th October 2012 Leila E. A. Nichol Royal Surrey County Hospital Leila.Nichol@nhs.net *My experience with Dosimetry
More informationImplementation of advanced RT Techniques
Implementation of advanced RT Techniques Tibor Major, PhD National Institute of Oncology Budapest, Hungary 2. Kongres radiološke tehnologije, Vukovar, 23-25. September 2016. Current RT equipments at NIO,
More informationEditorial Process: Submission:11/14/2017 Acceptance:07/31/2018
DOI:10.22034/APJCP.2018.19.9.2499 Dosimetric Comparison of SIB IMRT vs SIB VMAT in Gliomas RESEARCH ARTICLE Editorial Process: Submission:11/14/2017 Acceptance:07/31/2018 Dosimetric Comparison and Feasibility
More informationBeyond the DVH: Voxelbased Automated Planning and Quality Assurance
1 Beyond the DVH: Voxelbased Automated Planning and Quality Assurance Presented by Chris McIntosh Research Associate Department of Medical Imaging & Physics Princess Margaret Cancer Centre C. McIntosh
More informationSBRT TREATMENT PLANNING: TIPS + TRICKS. Rachel A. Hackett CMD, RT(T)
SBRT TREATMENT PLANNING: TIPS + TRICKS Rachel A. Hackett CMD, RT(T) OUTLINE Brief radiobiology review 3D CRT Tx Planning VMAT Tx Planning Protocols Other Sites Oligomets Spine Liver Kidney Adrenal Gland
More informationEvaluation of Three-dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy Techniques in High-Grade Gliomas
1 Carol Boyd Comprehensive Case Study July 11, 2013 Evaluation of Three-dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy Techniques in High-Grade Gliomas Abstract: Introduction:
More informationEvaluation of Whole-Field and Split-Field Intensity Modulation Radiation Therapy (IMRT) Techniques in Head and Neck Cancer
1 Charles Poole April Case Study April 30, 2012 Evaluation of Whole-Field and Split-Field Intensity Modulation Radiation Therapy (IMRT) Techniques in Head and Neck Cancer Abstract: Introduction: This study
More informationCan we deliver the dose distribution we plan in HDR-Brachytherapy of Prostate Cancer?
Can we deliver the dose distribution we plan in HDR-Brachytherapy of Prostate Cancer? Dimos Baltas Dept. of Medical Physics & Engineering, Strahlenklinik, Klinikum Offenbach GmbH 63069 Offenbach, Germany
More informationA Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer
A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer Tony Kin Ming Lam Radiation Planner Dr Patricia Lindsay, Radiation Physicist Dr John Kim, Radiation Oncologist Dr Kim Ann Ung,
More informationVOLUMETRIC-MODULATED ARC THERAPY VS. 3D-CONFORMAL RADIOTHERAPY FOR BREAST CANCER
Romanian Reports in Physics, Vol. 67, No. 3, P. 978 986, 2015 VOLUMETRIC-MODULATED ARC THERAPY VS. 3D-CONFORMAL RADIOTHERAPY FOR BREAST CANCER D. ADAM 1, 2, M.D. SUDITU 1, 2, R. POPA 1, 2, V. CIOCALTEI
More informationDosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer
Dosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer Tan Chek Wee 15 06 2016 National University Cancer Institute, Singapore Clinical Care Education Research
More informationJean Pouliot, PhD Professor and Vice Chair, Department of Radiation Oncology, Director of Physics Division
IMRT / Tomo / VMAT / Cyberknife / HDR Brachytherapy: Jean Pouliot, PhD Professor and Vice Chair, Department of Radiation Oncology, Director of Physics Division Should Choices be Based on Dosimetric and
More informationIMRT IN HEAD NECK CANCER
IMRT IN HEAD NECK CANCER THE SEARCH FOR CONFORMALITY CONVENTIONAL RT Simple field arrangements Uniformly radiate both the target and the surrounding normal tissues. Includes the use of rectangular blocks
More informationTreatment of exceptionally large prostate cancer patients with low-energy intensity-modulated photons
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 7, NUMBER 4, FALL 2006 Treatment of exceptionally large prostate cancer patients with low-energy intensity-modulated photons Mei Sun and Lijun Ma a University
More informationA TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM *
Romanian Reports in Physics, Vol. 66, No. 2, P. 394 400, 2014 A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM * D. ADAM 1,2,
More informationOverview of Clinical and Research Activities at Georgetown University Hospital
Overview of Clinical and Research Activities at Georgetown University Hospital Dalong Pang, Ph.D. Department of Radiation Medicine Georgetown University Hospital Clinical Operation Two Varian linear accelerators
More informationA STUDY OF PLANNING DOSE CONSTRAINTS FOR TREATMENT OF NASOPHARYNGEAL CARCINOMA USING A COMMERCIAL INVERSE TREATMENT PLANNING SYSTEM
doi:10.1016/j.ijrobp.2004.02.040 Int. J. Radiation Oncology Biol. Phys., Vol. 59, No. 3, pp. 886 896, 2004 Copyright 2004 Elsevier Inc. Printed in the USA. All rights reserved 0360-3016/04/$ see front
More informationLa Pianificazione e I Volumi di Trattamento
TRATTAMENTI INTEGRATI NEL CARCINOMA DELLA VULVA La Pianificazione e I Volumi di Trattamento PAOLO MUTO Direttore UOC Radioterapia ISTITUTO NAZIONALE TUMORI IRCCS Fondazione Pascale di Napoli Minimize collateral
More informationEvaluation of the Dynamic Arc-Therapy in Comparison to Conformal Radiation Therapy in Radiotherapy Patients
Evaluation of the Dynamic Arc-Therapy in Comparison to Conformal Radiation Therapy in Radiotherapy Patients Aliaa Mahmoud (1,4), Ehab M. Attalla (2,3), M..S. El-Nagdy (4), Gihan Kamel (4) (1) Radiation
More informationSpecifics of treatment planning for active scanning and IMPT
Specifics of treatment planning for active scanning and IMPT SFUD IMPT Tony Lomax, Centre for Proton Radiotherapy, Paul Scherrer Institute, Switzerland Treatment planning for scanning 1. Single Field,
More informationInternational Multispecialty Journal of Health (IMJH) ISSN: [ ] [Vol-3, Issue-9, September- 2017]
Dosimetric evaluation of carcinoma nasopharynx using Volumetric Modulated Arc Therapy (VMAT): An institutional experience from Western India Dr. Upendra Nandwana 1, Dr. Shuchita Pathak 2, Dr. TP Soni 3,
More informationOptimising Radiotherapy Using NTCP Models: 17 Years in Ann Arbor
Individualizing Optimizing Optimising Radiotherapy Using NTCP Models: 17 Years in Ann Arbor Randall K. Ten Haken, Ph.D. University of Michigan Department of Radiation Oncology Ann Arbor, MI Introduction
More informationProstate volumetric-modulated arc therapy: dosimetry and radiobiological model variation between the single-arc and double-arc technique
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 14, NUMBER 3, 2013 Prostate volumetric-modulated arc therapy: dosimetry and radiobiological model variation between the single-arc and double-arc technique
More informationBiological/Clinical Outcome Models in RT Planning
Biological/Clinical Outcome Models in RT Planning Randy Ten Haken Ken Jee University of Michigan Why consider use of models? Are there problems that use of outcomes models could help resolve? Would their
More informationClinical Usage of Knowledge Based Treatment Planning
Clinical Usage of Knowledge Based Treatment Planning Xiaodong Zhang Department of Radiation Physics, UT MDACC Disclosures Research funds from Sister Institution Network Funds from MDACC Varian Medical
More informationMaster s science Thesis. Evaluation of gantry angle optimization for IMRT treatment planning systems using the Pareto front approach.
Master s science Thesis Evaluation of gantry angle optimization for IMRT treatment planning systems using the Pareto front approach Maria Thor Supervisors: Anna Karlsson 1, Claus Behrens 1, Per Engström
More informationATC/NEMA/AAPM DICOM Demonstration. Walter R. Bosch, D.Sc.
ATC/NEMA/AAPM DICOM Demonstration Walter R. Bosch, D.Sc. Two-Phase Strategy for DICOM Demonstration 1. Demonstrate export of ATC-Compliant DICOM RT objects (or as large a subset as possible) 2. Demonstrate
More informationOptimization of RapidArc for Head-and-Neck Radiotherapy. Jessica Emily Salazar. Department of Medical Physics Duke University.
Optimization of RapidArc for Head-and-Neck Radiotherapy by Jessica Emily Salazar Department of Medical Physics Duke University Date: Approved: Shiva Das, Supervisor Ryan McMahon Robert Reiman Thesis submitted
More informationTreatment Planning for Lung. Kristi Hendrickson, PhD, DABR University of Washington Dept. of Radiation Oncology
Treatment Planning for Lung Kristi Hendrickson, PhD, DABR University of Washington Dept. of Radiation Oncology Outline of Presentation Dosimetric planning strategies for SBRT lung Delivery techniques Examples
More informationKenny Guida, DMP, DABR March 21 st, 2015
Kenny Guida, DMP, DABR March 21 st, 2015 Breast Cancer Treatment planning and delivery Hypofractionation Trials Hybrid Planning History Techniques RTOG 1005 Trial Hybrid-VMAT Research project 3D Tangents
More informationFeasibility of 4D IMRT Delivery for Hypofractionated High Dose Partial Prostate Treatments
Feasibility of 4D IMRT Delivery for Hypofractionated High Dose Partial Prostate Treatments R.A. Price Jr., Ph.D., J. Li, Ph.D., A. Pollack, M.D., Ph.D.*, L. Jin, Ph.D., E. Horwitz, M.D., M. Buyyounouski,
More informationA dosimetric comparison of proton and photon therapy in unresectable cancers of the head of pancreas
A dosimetric comparison of proton and photon therapy in unresectable cancers of the head of pancreas Reid F. Thompson University of Pennsylvania, Philadelphia, Pennsylvania 1914 Sonal U. Mayekar Thomas
More informationOutline. Chapter 12 Treatment Planning Combination of Beams. Opposing pairs of beams. Combination of beams. Opposing pairs of beams
Chapter 12 Treatment Planning Combination of Beams Radiation Dosimetry I Text: H.E Johns and J.R. Cunningham, The physics of radiology, 4 th ed. http://www.utoledo.edu/med/depts/radther Outline Combination
More informationRole of adaptive radiation therapy for pediatric patients with diffuse pontine glioma
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 12, NUMBER 2, spring 2011 Role of adaptive radiation therapy for pediatric patients with diffuse pontine glioma Chris Beltran, a Saumya Sharma, and Thomas
More informationFirst, how does radiation work?
Hello, I am Prajnan Das, Faculty Member in the Department of Radiation Oncology at The University of Texas MD Anderson Cancer Center. We are going to talk today about some of the basic principles regarding
More informationTransition to Heterogeneity Corrections. Why have accurate dose algorithms?
Transition to Heterogeneity Corrections Eric E. Klein, M.S., Washington University, St. Louis, MO Craig Stevens, M.D., Ph.D., MD Anderson Cancer Center, Houston, TX Nikos Papinikolou, Ph.D., University
More information3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis
Iran. J. Radiat. Res., 2007; 5 (1): 1-8 3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis A.K. Bhardwaj 1*,T.S.
More informationART for Cervical Cancer: Dosimetry and Technical Aspects
ART for Cervical Cancer: Dosimetry and Technical Aspects D.A. Jaffray, Ph.D. Radiation Therapy Physics Princess Margaret Cancer Centre/Techna/Ontario Cancer Institute Professor Departments of Radiation
More informationIntroduction of RapidArc TM : an example of commissioning and implementing a QA programme for a new technology
Introduction of RapidArc TM : an example of commissioning and implementing a QA programme for a new technology Philip Mayles Clatterbridge Centre for Oncology, Wirral, UK 1 What is RapidArc (or VMAT)?
More informationFiducial-Free Lung Tracking and Treatment with the CyberKnife System: A Non-Invasive Approach
Fiducial-Free Lung Tracking and Treatment with the CyberKnife System: A Non-Invasive Approach Jesse McKay, MS, DABR Erlanger Health System Chattanooga, TN JASTRO 2014, Yokohama Japan Disclosure I have
More informationJOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 15, NUMBER 3, 2014
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 15, NUMBER 3, 2014 Dosimetric study of uniform scanning proton therapy planning for prostate cancer patients with a metal hip prosthesis, and comparison
More informationThis article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and
This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and education use, including for instruction at the authors institution
More informationImpact of MLC properties and IMRT technique in meningioma and head-and-neck treatments
Kantz et al. Radiation Oncology (2015) 10:184 DOI 10.1186/s13014-015-0447-z RESEARCH Impact of MLC properties and IMRT technique in meningioma and head-and-neck treatments Steffi Kantz 1*, Matthias Söhn
More informationPotential benefits of intensity-modulated proton therapy in head and neck cancer van de Water, Tara Arpana
University of Groningen Potential benefits of intensity-modulated proton therapy in head and neck cancer van de Water, Tara Arpana IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's
More informationIndependent Dose Verification for IMRT Using Monte Carlo. C-M M Charlie Ma, Ph.D. Department of Radiation Oncology FCCC, Philadelphia, PA 19111, USA
Independent Dose Verification for IMRT Using Monte Carlo C-M M Charlie Ma, Ph.D. Department of Radiation Oncology FCCC, Philadelphia, PA 19111, USA Outline Why Monte Carlo for IMRT QA? Experimental verification
More informationCan we deliver the dose distribution we plan in HDR-Brachytherapy of Prostate Cancer?
Can we deliver the dose distribution we plan in HDR-Brachytherapy of Prostate Cancer? Dimos Baltas 1,3, Natasa Milickovic 1, Nikolaos Zamboglou 2 1 Dept. of Medical Physics & Engineering, 2 Strahlenklinik,
More informationDeveloping a Quality Index for Dose-Volume Histograms Based on Physician Preference. Alex Tyler Price
Developing a Quality Index for Dose-Volume Histograms Based on Physician Preference by Alex Tyler Price Graduate Program in Medical Physics Duke University Date: Approved: Joseph Y. Lo, Supervisor Shiva
More information8/2/2012. Transitioning from 3D IMRT to 4D IMRT and the Role of Image Guidance. Part II: Thoracic. Peter Balter, Ph.D.
8/2/2012 Transitioning from 3D IMRT to 4D IMRT and the Role of Image Guidance Part II: Thoracic Peter Balter, Ph.D. Disclosure Dr. Balter is Physics PI on a trial comparing Cyberknife based SBRT with surgery,
More informationBeyond The Dvh - Spatial And Biological Radiotherapy Treatment Planning
Wayne State University Wayne State University Dissertations 1-1-2010 Beyond The Dvh - Spatial And Biological Radiotherapy Treatment Planning Bo Zhao Wayne State University Follow this and additional works
More informationResearch Article An IMRT/VMAT Technique for Nonsmall Cell Lung Cancer
Hindawi Publishing Corporation BioMed Research International Volume 2015, Article ID 613060, 7 pages http://dx.doi.org/10.1155/2015/613060 Research Article An IMRT/VMAT Technique for Nonsmall Cell Lung
More informationFrom position verification and correction to adaptive RT Adaptive RT and dose accumulation
From position verification and correction to adaptive RT Adaptive RT and dose accumulation Hans de Boer Move away from Single pre-treatment scan Single treatment plan Treatment corrections by couch shifts
More informationSpatially Fractionated GRID Therapy: A Case Study Abstract: Introduction: Case Description: Conclusion: Key Words Introduction
1 Spatially Fractionated GRID Therapy: A Case Study Authors: Maggie Stauffer, B.S., Ellie Hawk, B.S., R.T.(R), Nishele Lenards, M.S., CMD, R.T.(R)(T), FAAMD, Ashley Hunzeker, M.S., CMD Abstract: Introduction:
More informationDosimetric and Biologic Differences in Flattened and Flattening-Filter-Free Beam Treatment Plans
Dosimetric and Biologic Differences in Flattened and Flattening-Filter-Free Beam Treatment Plans Yue Yan, PhD *, Poonam Yadav, PhD,, Michael Bassetti, MD, PhD, Kaifang Du, PhD, Daniel Saenz, PhD *,, Paul
More informationThe Accuracy of 3-D Inhomogeneity Photon Algorithms in Commercial Treatment Planning Systems using a Heterogeneous Lung Phantom
The Accuracy of 3-D Inhomogeneity Photon Algorithms in Commercial Treatment Planning Systems using a Heterogeneous Lung Phantom Gary Fisher, B.S. David Followill, Ph.D. Geoffrey Ibbott, Ph.D. This investigation
More informationReport of ICRU Committee on Volume and Dose Specification for Prescribing, Reporting and Recording in Conformal and IMRT A Progress Report
Report of ICRU Committee on Volume and Dose Specification for Prescribing, Reporting and Recording in Conformal and IMRT A Progress Report Paul M. DeLuca, Jr. 1, Ph.D., Vincent Gregoire 2, M.D., Ph.D.,
More information