IRIS Polymeric SPE & Accessories
|
|
- Gervais Byrd
- 5 years ago
- Views:
Transcription
1 IRIS Polymeric SPE & Accessories Chrom Philosophy In April, a group of independent distributors met to discuss the dynamic shift in the chromatography consumables market. The group concluded that mergers and acquisitions in the chromatography consumables industry have limited the offerings available to the laboratory scientist. These users of chromatography consumables and buyers of companies from small to large are faced with limited offerings, meaning less choice and less competitive pricing. Aiming to provide more options and let local independent distributors operate on a more level playing field, the idea of a buying group was born. This buying group would enable these local distributors, who are specialized experts in chromatography, to compete with world-class quality products, yet maintaining a strong relationship with the customer. The realization of this idea is Chrom. Global companies, who purchase for many worldwide locations can benefit from our distributors by receiving group pricing and maintain the same quality with uniform pricing for all their locations. IRIS Polymeric SPE & Accessories Sorbent Properties Sorbent Selection Sorbent Mass Selection IRIS MCX IRIS WCX IRIS PLUS IRIS IRIS WAX Distributed for Chrom by: IRIS MAX Applications Sample Extraction Products General Method Guide For global contracts please contact global@chrom.com
2 IRIS Polymeric SPE Sorbents IRIS sorbents are available in six different phase chemistries offering maximum flexibility for method development. IRIS General Method Guidelines Sorbent Analyte Properties Matrix/Sample Retention Elution MIXED-MDE CATI-EXCAGE Low pka Phase IRIS PLUS % Divinylbenzene RP phase Pore size: Å Surface area: ~7 m /g IRIS Polyamide phase - LB* type sorbent Pore size: Å Surface area: ~5 m /g * Localized hydrophilic/lipophilic base IRIS MCX IRIS WCX Charged/Ionized compounds Cation-exchange (basic) analytes on-polar to moderately Aqueous diluted with buffer Example: Biological fluids igher % of aqueous solvent (water) Lower % of organic solvent Lower ionic strength polar hydrophobic eutral with buffer p < pka of analyte p > pka of sorbent MIXED-MDE AI-EXCAGE Lower % of aqueous solvent (water) igher % of organic solvent igher ionic strength p > pka of analyte p < pka of sorbent IRIS WCX rganic acid on DVB phase Pore size: Å Ion-Exchange capacity: ~1 meq/g pka ~5 Available in 5-35 µm Available in various cartridge sizes and 9-well plate formats IRIS WAX Secondary amine on DVB phase Pore size: Å Ion-Exchange capacity: ~1 meq/g pka ~7 IRIS MAX IRIS WAX Charged/Ionized compounds Anion-exchange (acidic) analytes on-polar to moderately polar hydrophobic eutral Aqueous diluted with buffer Example: Biological fluids with buffer REVERSED-PASE igher % of aqueous solvent (water) Lower % of organic solvent Lower ionic strength p > pka of analyte p < pka of sorbent Lower % of aqueous solvent (water) igher % of organic solvent igher ionic strength p < pka of analyte p > pka of sorbent igh pka Phase IRIS MCX Sulfonated hydrophilic on DVB phase Pore size: Å Ion-Exchange capacity: ~1 meq/g pka <1 IRIS MAX Quaternary amine phase on DVB phase Pore size: Å Ion-Exchange capacity: ~.1 meg/g pka >1 IRIS PLUS IRIS on-polar to moderately polar hydrophobic eutral Example: Pharmaceuticals, pesticides, herbicides, Alkaloids Aqueous diluted with buffer Example: Biological fluids, water RMAL-PASE igher % of aqueous solvent (water) Lower % of organic solvent p adjusted buffer to place analyte in neutral form (if applicable) Lower % of aqueous solvent (water) igher % of organic solvent p adjusted buffer to place analyte in charged form (if applicable) Advantages of Polymeric Solid Phase Extraction IRIS Moderate to highly polar eutral Example: Pesticides on-polar to moderately polar organic Example: Biological fluids, oil, fats igher % of organic solvent Lower % of aqueous solvent (water) p adjusted buffer to place analyte in neutral form (if applicable) Lower % of organic solvent igher % of water p adjusted buffer to place analyte in neutral form (if applicable) 1. Excellent recovery - highly retentive nature of polymeric phases. igh surface area that results in higher analyte capacity compared to silica based SPE 3. Reduced resin volumes for improved detection limits and reduced drying time. Inert to a wide array of solvents and p ranges 5. Absence of leachables. Absence of residual silanol groups 7. Resistant to dewetting This table provides general method guidelines. Each IRIS polymeric SPE box contains detailed instructions for each specific phase.
3 IRIS Sorbent Selection Guidelines Analyte Properties Strong Base? YES IRIS MCX page # IRIS WCX page # *Acid, eutral, or *Base? Retention of eutrals? STRG BALACED IRIS PLUS page # IRIS page # * If analytes contain both acids and bases, select the dominant interaction. Strong Acid? YES IRIS WAX page #1 IRIS MAX page # Sample Type and Sorbent Mass Guidelines Industry Typical Example Typical Sample Volume Recommended Sorbent Mass Recommended Reservoir Environmental Food & Agriculture Clinical & Bioanalysis Drinking water, Surface water, Waste water, Soil Food homogenate from Fish, Fruit, Meat, Poultry, Wheat Blood, Plasma, Urine diluted.1 L to 1 L mg ml 1 ml to 3 ml mg 3 ml. ml to 3 ml 3 mg 1 ml IRIS Sorbent Mass Minimum Recommended Elution Volume Typical Elution Volume 5 mg 5 ml ml to 5 ml mg ml 3 ml to ml mg µl 1. ml to 3 ml 3 mg 3 µl. ml to ml mg µl.3 ml to 1 ml * Elution volumes depend on the chemical nature of the analyte, its relative concentration in the matrix, the chemistry of the solution solvent and the sorbent bed mass. Please be advised that the tables above provide general guidelines. Please contact our technical support team for specific method development support or guidelines for specific applications. 1
4 iris plus iris plus PLUS PLUS % Divinylbenzene (DVB) phase Pore Size: Å Surface area: ~7 m /g Available in 5-35 µm particle size Available in various cartridge sizes and 9-well plate formats The IRIS PLUS is a % DVB phase. This unique polymer phase is our most retentive reversed-phase sorbent. It is a great replacement for your current C1 or PS-DVB SPE sorbents. Features & Benefits igher Recoveries due to the highly retentive nature of the DVB packing material Lower Background Signals proprietary cleaning process for ultrapure resins decreasing background signals Durability stability at p extremes of - Improved Detection Limits and Reduced Drying Time using reduced resin volumes Eliminate Matrix Effects cleaner sample extracts reduce or eliminate matrix ion suppression IRIS PLUS most hydrophobic reversed-phase available Excellent for environmental samples IRIS PLUS SPE Cartridges IRIS PLUS APPLICATI IR3 IRIS PLUS mg/1ml 5-35µm IR31 IRIS PLUS 3mg/1mL 5-35µm IR3 IRIS PLUS 3mg/3mL 5-35µm Recovery Rates: IRIS PLUS - mg/ml IR35 µg/ml in Polycyclic aromatic hydrocarbons - PA IR3 IRIS PLUS mg/3ml 5-35µm IR3 IRIS PLUS mg/3ml 5-35µm IR35 IRIS PLUS mg/ml 5-35µm 3 Chrysene Benzo(a) Anthracene Benzo(b)Fluoranthene Benzo(j)Fluoranthene Benzo(k)Fluoranthene IR3 IRIS PLUS 5mg/mL 5-35µm 3.%.5% IRIS PLUS SPE 9-well Plates IR931 IRIS PLUS 9-well mg/1ml 5-35µm 1 IR933 IRIS PLUS 9-well 3mg/1mL 5-35µm 1 Benzo(a)pyrene Benzo(e)pyrene.5% Indeno(1,,3-cd)pyrene Benzo(g,h,i)perylene Dibenz(a,h)anthracene 9.7% Group 1 Group Group 3 Group IR935 IRIS PLUS 9-well mg/1ml 5-35µm 1 IR937 IRIS PLUS 9-well 3mg/mL 5-35µm 1 IR93 IRIS PLUS 9-well mg/ml 5-35µm 1 Figure 1: GCMS Chromatogram 3
5 iris n iris n R1 R R3 Polyamide phase - LB type sorbent Pore size: Å Surface area: ~5 m /g Available in 5-35 µm particle size Available in various cartridge sizes and 9-well plate formats Features & Benefits Localized ydrophilic/lipophilic Base (LB type sorbent) using a combination of polar and non-polar interactions to provide optimal analyte/resin contact Polyamide Stationary Phase excellent water wettability using reversed-phase mode up to % aqueous solvent or normal-phase mode using up to % organic solvents This novel polyamide polymer phase provides a highly hydrophilic/lipophilic balance making it the SPE material with the widest applicability. The outstanding reversed-phase characteristics of this material are only one part of this material s success. This phase chemistry offers multiple interaction mechanisms and can be used for both reversedphase and normal-phase applications. IRIS SPE Cartridges IR IRIS mg/1ml 5-35µm IR1 IRIS 3mg/1mL 5-35µm IR IRIS 3mg/3mL 5-35µm IR IRIS mg/3ml 5-35µm IR IRIS mg/3ml 5-35µm IR5 IRIS mg/ml 5-35µm 3 IR IRIS 5mg/mL 5-35µm 3 IRIS APPLICATI IRIS - 3mg/1mL IR1 µg/ml in Recovery Rates: Estriol ydrocortisone Betamethasone Run 1 9.5% Run 1.% Run 1.3% Run.1% Run.% Run.% Run 3 9.3% Run 3 3.% Run 3.% Estriol Estriol, ydrocortisone, Betamethasone ydrocortisone IRIS SPE 9-well Plates 1 IR91 IRIS 9-well mg/1ml 5-35µm 1 IR93 IRIS 9-well 3mg/1mL 5-35µm 1 IR95 IRIS 9-well mg/1ml 5-35µm 1 IR97 IRIS 9-well 3mg/mL 5-35µm 1 IR9 IRIS 9-well mg/ml 5-35µm 1 Estriol ydrocortisone Beamethasone Betamethasone F 5
6 iris mcx iris mcx MCX MCX Sulfonated DVB phase Pore size: Å Ion-Exchange capacity: ~1 meq/g pka <1 Available in 5-35 µm particle size Available in various cartridge sizes and 9-well plate formats Features & Benefits Sulfonated DVB Phase allows for cation-exchange and reversed-phase separations % DVB no swelling, increased retention, excellent flow properties and p stability Excellent Wettability even after drying, due to hydrophilic/hydrophobic balance IRIS MCX is a water-wettable sulfonated divinylbenzene mixed-mode phase for both cation-exchange and reversedphase applications. IRIS MCX allows for easy method development, through its dual retention qualities, for a wide range of basic and neutral compounds. IRIS MCX shows excellent retention for essentially all of the common basic drugs of abuse and similar amine containing compounds. The phase is stable over the complete p range (-) and can be used with nearly any solvent, allowing the use of a wide range of solvents. IRIS MCX SPE Cartridges IR5 IRIS MCX mg/1ml 5-35µm IR51 IRIS MCX 3mg/1mL 5-35µm IR5 IRIS MCX 3mg/3mL 5-35µm IR5 IRIS MCX mg/3ml 5-35µm IR5 IRIS MCX, mg/3ml 5-35µm IR55 IRIS MCX mg/ml 5-35µm 3 IRIS MCX APPLICATI IRIS MCX - 3 mg/1ml IR51 5 µg/ml in.1% Formic Acid Recovery Rates: orephedrine Ephedrine ydrochloride ydrochloride Run 1 9.% Run 1 9.7% Run 91.% Run 9.7% Run 3 93.% Run 3 9.% orephedrine & Ephedrine ydrochloride ote 1: After wash step cartridge was dried for 1 minute using vac. The collected elute solution was placed in a ml volumetric and brought to the mark with (.1% formic acid). orephedrine ydrochloride IR5 IRIS MCX 5mg/mL 5-35µm 3 IRIS MCX SPE 9-well Plates 3 IR951 IRIS MCX 9-well mg/1ml 5-35µm 1 IR953 IRIS MCX 9-well 3mg/1mL 5-35µm orephedrine ydrochloride Ephedrine ydrochloride Ephedrine ydrochloride IR955 IRIS MCX 9-well mg/1ml 5-35µm 1 IR957 IRIS MCX 9-well 3mg/mL 5-35µm 1 3 IR95 IRIS MCX 9-well mg/ml 5-35µm 1-1 7
7 iris wcx iris wcx WCX WCX rganic acid on DVB phase Pore size: Å Ion-Exchange capacity: ~1 meq/g pka ~5 Available in 5-35 µm particle size Available in various cartridge sizes and 9-well plate formats Features & Benefits rganic Acid Phase allows for tunable selectivity for strong bases % DVB no swelling, increased retention, excellent flow properties and p stability Retain and Release easy separation of strong bases Uniquely Selective fast and efficient sample preparation and purification for strong bases IRIS WCX is a weak cation-exchange divinylbenzene polymer phase. IRIS WCX eliminates the guesswork commonly found in lengthy method development associated with strong bases such as quaternary amines. This phase utilizes the chemical functionality of a carboxylic acid. When the phase is negatively charged, it retains strong bases such as quaternary amines and releases them when neutral. IRIS WCX has repeatedly proven consistency and reliability, reducing the need for time consuming and costly retesting. IRIS WCX APPLICATI IRIS WCX SPE Cartridges IRIS WCX - 3 mg/1ml IR13 5 µg/ml in Sulfonamides IR1 IRIS WCX mg/1ml 5-35µm IR13 IRIS WCX 3mg/1mL 5-35µm IR3 IRIS WCX 3mg/3mL 5-35µm IR1 IRIS WCX mg/3ml 5-35µm Recovery Rates: Sulfadiazine Sulfathiazole Sulfamerazine Sulfamethazine Run 1 9.% Run 1 95.% Run % Run % Run.% Run 9.1% Run.5% Run 99.% Run 3 9.% Run 3 93.% Run 3 95.% Run 3 9.5% IR19 IRIS WCX mg/ml 5-35µm 3 IR IRIS WCX 5mg/mL 5-35µm 3 Sulfadiazine Sulfamerazine IR1 IRIS WCX 1gram/mL 5-35µm IRIS WCX SPE 9-well Plates 1 1 Sulfathiazole Sulfadiazine Sulfamerazine IR97 IRIS WCX 9-well mg/1ml 5-35µm 1 IR97 IRIS WCX 9-well 3mg/1mL 5-35µm 1 IR971 IRIS WCX 9-well mg/1ml 5-35µm 1 IR97 IRIS WCX 9-well 3mg/mL 5-35µm 1 Sulfathiazole 1 Sulfamethazine Sulfamethazine IR97 IRIS WCX 9-well mg/ml 5-35µm S 9
8 iris max iris max MAX MAX Quaternary amine on DVB phase Pore size: Å Ion-Exchange capacity: ~.1 meq/g pka >1 Available in 5-35 µm particle size Available in various cartridge sizes and 9-well plate formats IRIS MAX is a water-wettable quaternary amine divinylbenzene polymer phase designed for both anion-exchange and reversed-phase extraction. As a result of its bifunctionality, IRIS MAX produces outstanding retention for charged and neutral compounds. It is excellent for compounds containing an organic acid or similar ionizable functional groups. The phase is stable over the complete p range (-) and can be used with nearly any solvent permitting the use of a wide range of solvents. Features & Benefits Quaternary Amine Phase allows for anion-exchange and reversed-phase separations % DVB no swelling, increased retention, excellent flow properties and p stability Excellent Wettability even after drying, due to hydrophilic/hydrophobic balance IRIS MAX APPLICATI IRIS MAX SPE Cartridges IRIS MAX - 3 mg/1ml IR1 µg/ml in DL-Tyrosine IR IRIS MAX mg/1ml 5-35µm IR1 IRIS MAX 3mg/1mL 5-35µm IR IRIS MAX 3mg/3mL 5-35µm IR IRIS MAX mg/3ml 5-35µm Recovery Rates: Run 1 9.9% Run 9.% Run % IR IRIS MAX, mg/3ml 5-35µm IR5 IRIS MAX mg/ml 5-35µm 3 IR IRIS MAX 5mg/mL 5-35µm 3 1 IRIS MAX SPE 9-well Plates DL-Tyrosine IR91 IRIS MAX 9-well mg/1ml 5-35µm 1 IR93 IRIS MAX 9-well 3mg/1mL 5-35µm 1 IR95 IRIS MAX 9-well mg/1ml 5-35µm 1 IR97 IRIS MAX 9-well 3mg/mL 5-35µm 1 IR9 IRIS MAX 9-well mg/ml 5-35µm
9 iris wax iris wax WAX WAX Secondary amine on DVB phase Pore size: Å Ion-Exchange capacity: ~1 meq/g pka ~7 Available in 5-35 µm particle size Available in various cartridge sizes and 9-well plate formats Features & Benefits Secondary Amine Phase allows for tunable selectivity for strong acids % DVB no swelling, increased retention, excellent flow properties and p stability Excellent Retention bifunctional with reversed-phase and anion-exchange behavior Uniquely Selective fast and efficient sample preparation and purification for strong acids IRIS WAX is a mixed-mode weak anion-exchange divinylbenzene polymer phase, designed to retain and release strong acids such as sulfates. Depending on the requirements of the application, this phase can be used in the neutral or positively charged state. IRIS WAX displays both anion-exchange and reversed-phase behavior, which promotes excellent retention over a wide range of hydrophilicity for both acidic, when phase is positively charged, and neutral compounds. IRIS WAX SPE Cartridges IR11 IRIS WAX mg/1ml 5-35µm IR1 IRIS WAX 3mg/1mL 5-35µm IR9751 IRIS WAX 3mg/3mL 5-35µm IRIS WAX APPLICATI IRIS WAX - 3 mg/1ml IR1 µg/ml in Recovery Rates: itro-l-tryosine Iodo-L-Tyrosine -Acetyl-L-Tyrosine Run 1 9.7% Run 1 9.% Run % Run 9.% Run 9.% Run.% Run 3 9.% Run 3 95.% Run 3 3.% itro-l-tyrosine, Iodo-L-Tyrosine, -Acetyl-L-Tyrosine IR IRIS WAX mg/3ml 5-35µm IR1 IRIS WAX mg/ml 5-35µm 3 itro-l-tyrosine Iodo-L-Tyrosine IR19 IRIS WAX 5mg/mL 5-35µm 3 IRIS WAX SPE 9-well Plates 19 itro-l-tyrosine I IR975 IRIS WAX 9-well mg/1ml 5-35µm 1 IR975 IRIS WAX 9-well 3mg/1mL 5-35µm 1 IR9751 IRIS WAX 9-well mg/1ml 5-35µm 1 9 Iodo-L-Tyrosine -Acetyl-L-Tyrosine -Acetyl-L-Tyrosine IR975 IRIS WAX 9-well 3mg/mL 5-35µm 1 IR975 IRIS WAX 9-well mg/ml 5-35µm
10 Applications - Environmental Applications - Environmental IRIS PLUS - mg/ml IR35 µg/ml in Polycyclic aromatic hydrocarbons - PA IRIS WCX - 3 mg/1ml IR13 µg/ml in Diquat Dibromide Recovery Rates: Chrysene Benzo(a) Anthracene Benzo(b)Fluoranthene Benzo(j)Fluoranthene Benzo(k)Fluoranthene Recovery Rates: Run 1 9.% Run 9.7% Run 3 5.%.% Benzo(a)pyrene Benzo(e)pyrene.5%.5% Indeno(1,,3-cd)pyrene Benzo(g,h,i)perylene Dibenz(a,h)anthracene 9.7% Group 1 Group Group 3 Group ote: The peak area values for Diquat were found to change over time. There was a relatively quick change to lower area values that then somewhat leveled off. The area values used for quantitation were for injections of the standards and the SPE solutions in this semi-stable time frame. This observed change in peak area over time is consistent with references that state the need to deactivate glassware prior to Diquat solution contact. In this analysis the SPE Diquat solution comes in contact with three different glass vessels. Diquat is not retained by the chromatographic column, eluting in the void volume. owever, the strong absorbance at 3nm allows for quantitation without interference Diquat Dibromide 5 Figure 1: GCMS Chromatogram Figure 1: GCMS Chromatogram Br + Br IRIS - 3 mg/1ml IR1 1, 1, 5, µg/ml in Carbaryl, Atrazine, Methiocarb, Alachlor IRIS MCX - 3 mg/1ml IR51 µg/ml in,3 Dihydroxynaphthalene Recovery Rates: Carbaryl Atrazine Methiocarb Alachlor Run 1.% Run 1 9.% Run 1 1.% Run 1 9.% Run.1% Run 1.1% Run 1.% Run 1.1% Run % Run 3.% Run 3 99.% Run 3.% Recovery Rates: Run 1 9.5% Run 3.% Run 3 1.% Carbaryl Methiocarb Atrazine CI C C 3 C C 3 C Carbaryl Methiocarb Atrazine Alachlor Alachlor CI C 3 3 C S C ,3 Dihydroxynaphthalene
11 Applications - Food & Agriculture Applications - Food & Agriculture IRIS MCX - mg/ml IR55 1 mg/ml in Melamine IRIS MCX - 3 mg/1ml IR51 5 µg/ml in Carbendazim, Thiabendazole Recovery Rates: Melamine 97% Internal Standard Recovery Rates: Carbendazim Thiabendazole Run 1 1.7% Run % Run.% Run.1% Run 3.% Run 3 9.% Carbendazim Melamine 3 9 Thiabendazole Thiabendazole 19 Carbendazim 9 IRIS - 3 mg/1ml IR1 5 µg/ml in Recovery Rates: Thiamphenicol Florfenicol Chloramphenicol Run 1 9.% Run % Run % Run 99.7% Run 1.1% Run.3% Run 3 99.% Run 3.% Run 3 99.% Thiamphenicol, Florfenicol, Chloramphenicol ote 1: Elution from the IRIS SPE cartridge was performed with 7% C3C. While % C3C appeared to fully elute the compounds, the chromatographic peak shape was significantly better when the SPE elution solvent was less than % C3C. 7% was used because it was already prepared, lower C3C may lead to more improvement in chromatographic peak shape. -1 IRIS WCX - 3 mg/1ml IR13 5 µg/ml in 1 Recovery Rates: Sulfadiazine Sulfathiazole Sulfamerazine Sulfamethazine Run 1 9.% Run 1 95.% Run % Run % Run.% Run 9.1% Run.5% Run 99.% Run 3 9.% Run 3 93.% Run 3 95.% Run 3 9.5% Sulfadiazine Sulfamerazine Sulfonamides Florfenicol 35 Sulfathiazole Thiamphenicol S CI CI Thiamphenicol Florfenicol Chloramphenicol Chloramphenicol C C Sulfathiazole Sulfadiazine Sulfamerazine Sulfamethazine 13 Sulfamethazine S 1 17
12 Applications - Clinical & Bioanalysis Applications - Clinical & Bioanalysis IRIS MCX mg/ml IR55 5 µg/ml in piates Codeine IRIS - 3 mg/1ml IR1 µg/ml in Prednisone, Methylprednisolone, Dexamethasone Recovery Rates: ydrocodone 95% Dihydrocodeine 91% Methylmorphine (Codeine) 9% xycodone % ydromorphone 93% Morphine 7% xymorphone 9% ydrocodone ydrocodone ISTD Dihydrocodeine xycodone ydromorphone -acetylmophine xymorphone Morphine Morphine ISTD Recovery Rates: Prednisone Methylprednisolone Dexamethasone Run 1.7% Run % Run 1.% Run 99.5% Run 9.3% Run 9.% Run 3 99.% Run % Run % ote: Elution of the hormones from the IRIS SPE cartridge was performed with % C 3 C. It was found that lower recoveries were obtained when using % C 3 C. Methylprednisolone C 3 C 3 C C C3 Methylmorphine (Codeine) 3C ydrocodone C3 Prednisone 1 Prednisone Methylprednisolone 13 Dexamethasone Dexamethasone 3 C C 3 F 3 C C 3 Dihydrocodeine Morphine IRIS - 3 mg/1ml IR1 5 µg/ml in Recovery Rates: Risperidone % Quitiapine Fumerate 3% Domperidone 3% xymorphone -acetylmorphine Antipsychotic Drugs IRIS - 3 mg/1ml IR1 Warfarin ( µg/ml), Carbamazapine (1 µg/ml), Diphenhydramine (5 µg/ml) in Recovery Rates: Warfarin Carbamazapine Diphenhydramine Run 1 93.% Run % Run 1.% Run 95.% Run 9.% Run.1% Run 3 9.% Run 3 99.% Run 3.1% Warfarin, Carbamazapine, Diphenhydramine Carbamazapine Warfarin 9 Risperidone Warfarin Carbamazapine Diphenhydramine Diphenhydramine C 3 C 3 Domperidone Quetiapine Fumarate
13 IRIS SPE Sample Extraction Products cartridges (syringe barrel & frits) Virgin polypropylene solid phase extraction cartridges with frits Available in format ranging from 1 ml to ml 9-well plates (deep well plate format) igh throughput SBS format plates compatible with most automated systems Available with mg, 3 mg and mg bed mass online columns & guard cartridges Design for online solid phase extraction using a switching valve Wide choice of column configuration nline guard columns are available in x.1 mm & x. mm packed with 5 µm of any of the six phase chemistries (please inquire) innosep vacuum manifolds InnoSep Vacuum manifolds for SPE sample preparation, filtration, and elution are available in 1, 1, and port configurations. These manifolds permit consistent extraction and filtration results. Multiple sample processing with these manifolds simplifies procedures and saves time. The manifolds consist of a clear glass chamber and lid to which a vacuum is applied to draw a sample through an SPE column, cartridge, or disk. Adjustable racks placed in the glass vacuum chamber will accommodate a variety of sample collection vessels, including test tubes, autosampler vials, volumetric flasks, and Erlenmeyer flasks. Eluents are deposited directly into the collection vessel of choice via polypropylene, optional stainless steel, or Teflon needles.
Supra-Clean and Supra-Poly Solid Phase Extraction (SPE) Solutions
Supra-Clean and Supra-Poly Solid Phase Extraction (SPE) Solutions Imagine how much faster, easier and more efficient your sample preparation would be if your Solid Phase Extraction (SPE) solutions were
More informationSPE Cartridges. All Finneran Products Are Certified. Conditioning Sample application Wash Elution
All Finneran Products Are Certified Finneran Solid Phase Extraction (SPE) cartridges provide a fast and efficient sample clean-up and concentration prior to analysis through GC, HPLC, and/or other instrument
More informationUltra Columns. also available. ordering note
: 3μm or 5μm particles; 100Å pore size Our broadest selection of stationary phases, including unique phases. High density bondings, for maximum retention. High-purity, Type B silica gives excellent peak
More informationSimplifying Solid-Phase Extraction [ OASIS SOLID-PHASE EXTRACTION PRODUCTS ]
Simplifying Solid-Phase Extraction [ OASIS SOLID-PHASE EXTRACTION PRODUCTS ] Through the combination of innovative sorbent technology and hardware design, Oasis Products have become the first choice in
More informationTaking the Complexity out of SPE Method Development
Taking the Complexity out of SPE Method Development Includes guidelines for the following: P SPE Format Selection P SPE Sorbent Selection P SPE Methods P SPE Volume Guidelines P Common Laboratory Conversions
More informationUltra Columns HPLC COLUMNS
Acetaminophen, Narcotic Analgesics.............519 Aldehydes, Ketones...........................500 Beclomethasone.............................523 Corticosteroids..............................529 Explosives..................................501
More informationStrata -X Polymeric SPE
Strata - Polymeric SPE Strata- Benefits of Strata- SPE vs. Traditional SPE Increase Detection Sensitivity by removing matrix contaminants Increase Column Lifetime by removing matrix contaminants Quality
More informationSample Preparation Techniques for Biological Matrices: Finding the right balance to achieve optimal results
Sample Preparation Techniques for Biological Matrices: Finding the right balance to achieve optimal results Presenter: Diana Wang Applications Engineer SPP-Support@agilent.com 1 Today s Agenda - Why sample
More informationSeQuant ZIC -HILIC For all who expect more...
SeQuant ZIC -ILIC For all who expect more... The better choice for PLC and LC/MS of all types of polar and hydrophilic compounds EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany Poor
More informationAgilent Technologies Prep LC Columns
Agilent Technologies Prep LC Columns Agilent Technologies Prep LC Columns Agilent Technologies has always taken seriously its responsibility to ensure your success. That s why all our instruments and supplies
More informationThe challenging extraction of non-polar contaminants out of a non-polar vegetable oil sample
The challenging extraction of non-polar contaminants out of a non-polar vegetable oil sample Presented by Michael Ye ExTech, 2014 sigma-aldrich.com/analytical 1 Agenda 1. Background; why and how analyze
More informationApplication Note. Abstract. Authors. Pharmaceutical
Analysis of xycodone and Its Metabolites-oroxycodone, xymorphone, and oroxymorphone in Plasma by LC/MS with an Agilent ZRBAX StableBond SB-C18 LC Column Application ote Pharmaceutical Authors Linda L.
More informationSeQuant ZIC -HILIC For all who expect more...
SeQuant ZIC -ILIC For all who expect more... The better choice for PLC and LC/MS of all types of polar and hydrophilic compounds EMD Millipore is a division of Merck KGaA, Darmstadt, Germany Poor retention
More informationThe Raptor HILIC-Si Column
The Raptor HILIC-Si Column With Raptor LC columns, Restek chemists became the first to combine the speed of superficially porous particles (also known as SPP or core-shell particles) with the resolution
More informationFast quantitative Forensic Analysis of THC and its Metabolites in Biological Samples using Captiva EMR- Lipid and LC/MSMS
Fast quantitative Forensic Analysis of THC and its Metabolites in Biological Samples using Captiva EMR- Lipid and LC/MSMS Christophe Deckers, M.Sc. Sample prep Application Scientist Types of ``Interferences``
More informationSystematic Evaluation of Solid Phase Extraction (SPE) Chemistries for the Determination of Acidic, Neutral, and Basic Drugs
Systematic Evaluation of Solid Phase Extraction (SPE) Chemistries for the Determination of Acidic, Neutral, and Basic Drugs Laura Marlatt, An Trinh, and David S. Bell Supelco, 595 North Harrison Road,
More informationSepax Technologies, Inc.
Sepax Technologies, Inc. Sepax Technologies, Inc. develops and manufactures products in the area of chemical and biological separations, biosurfaces and proteomics. Sepax product portfolio includes ) liquid
More informationFiltration Approaches to Sample Preparation and Cleanup. Golnar Javadi Application Engineer Sample Preparation Products
Filtration Approaches to Sample Preparation and Cleanup Golnar Javadi Application Engineer Sample Preparation Products Spp-support@agilent.com 1 Today s Agenda How does filtration work a brief overview
More informationHigh Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS)
High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS) Michael Rummel, Matthew Trass, Michael Campognone, and Sky Countryman Phenomenex, Inc., 411 Madrid Avenue, Torrance,
More informationSample Preparation. Sample Preparation. We are focused on quality and reproducibility. ~ Pat Curtis, Principal Process Chemist, Wexford, Ireland
Sample Preparation Sample Preparation We are focused on quality and reproducibility. ~ Pat Curtis, Principal Process Chemist, Wexford, Ireland Contents Goals of Sample Preparation... 5 Selecting the Correct
More informationSPE and QuEChERS Method Development. Tina Chambers Christophe Deckers lent.com
SPE and QuEChERS Method Development Tina Chambers Christophe Deckers lent.com 1 Today s Agenda 1. QuEChERS Workflow overview and original methods 2. Method development for alternative matrices 3. SPE for
More informationLC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D
LC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D Introduction Components of pharmaceutical products and food products often include high
More informationKeep it Clean with Strata -X
Simplified Solid Phase Extraction Solutions Neutral Compounds Acidic Compounds Basic Compounds Strong Acids (pk a < 2 Weak Acids (pk a 2-4 Neutral Compounds Weak Bases (pk a 8-10 Strong Bases (pk a > 10
More informationCatalogue. Resins and Columns For High Performance Liquid Chromatography
Catalogue Resins and Columns For High Performance Liquid Chromatography Updated August 11, 2008 Contents Benson Polymeric provides premium polymeric column packing materials and prepacked columns for use
More informationPerformance of an ultra low elution volume 96-well plate
Performance of an ultra low elution volume 96-well plate Claude R. Mallet, Ziling Lu, Jeff R. Mazzeo, Uwe D. Neue Waters Corporation PittCon 2003 March 10-14 2003 Orlando, Florida Today s Challenges Faced
More informationRemoval of Triton X-100 from Plasma Samples Using Mixed-Mode Solid Phase Extraction (SPE)
Removal of Triton X- from Plasma Samples Using Mixed-Mode Solid Phase Extraction (SPE) Jonathan P. Danaceau, Erin Chambers, and Kenneth J. Fountain Waters Corporation, 34 Maple Street, Milford, MA USA
More informationMultilayer SPE Tubes for Pesticide Analysis
Page 1 of 6 Return to Web Version Solid Phase Extraction Multilayer SPE Tubes for Pesticide Analysis The multi-residue surveillance of pesticides in agricultural products (fruits, vegetables, meat, shellfish,
More informationChromatogram Search Tool Search by compound name, synonym, CAS # or keyword Pinnacle II Columns
: 3μm or 5μm particles; 110Å pore size Silica at, for total control of quality and reproducibility. Excellent replacement for the original Hypersil material. Physical and chromatographic properties similar
More information[ APPLICATION NOTE ] Oasis PRiME HLB Cartridge for Cleanup of Infant Formula Extracts Prior to UPLC-MS/MS Multiresidue Veterinary Drugs Analysis
Prior to UPLC-MS/MS Multiresidue Veterinary Drugs Analysis Michael S Young and Kim Van Tran Waters Corporation, Milford, MA, USA APPLICATION BENEFITS Efficient, timesaving multiclass/ multiresidue methodology
More informationGlycanPac AXH-1 Columns
Thermo Scientific GlycanPac AXH-1 Columns Product Manual P/N: 065479-01 January 2013 Part of Thermo Fisher Scientific Product Manual for GlycanPac AXH-1 Columns GlycanPac AXH-1, 1.9 µm, Analytical, 2.1
More informationLC Columns with Liquid Separation Cell Technology
Obelisc LC Columns with Liquid Separation Cell Technology Obelisc HPLC Columns - Liquid Separation Cell Technology Introduction Obelisc HPLC columns are the latest, innovative columns from SIELC Technologies,
More informationAnalytical and Preparative SFC Columns
Analytical and Preparative SFC Columns Best Performance for Supercritical Fluid Chromatography Sepax SFC-Cyano... Sepax SFC-Amino... Sepax SFC-Pyridine... Sepax SFC-SCX... 5 Sepax SFC-Diol... 6 Sepax SFC-Silica...
More informationDetermination of Tetracyclines in Chicken by Solid-Phase Extraction and High-Performance Liquid Chromatography
Determination of Tetracyclines in Chicken by Solid-Phase Extraction and High-Performance Liquid Chromatography Application ote Food Safety Authors Chen-Hao Zhai and Yun Zou Agilent Technologies Co. Ltd.
More informationSample Concentration and Analysis of Human Hormones in Drinking Water
Sample Concentration and Analysis of Human Hormones in Drinking Water Carl Fisher Applications Chemist Ion Chromatography/Sample Preparation Thermo Fisher Scientific March 1, 215 1 The world leader in
More informationLC-MS/MS analysis of Chlorates in Milk and Whey Powder using the Agilent 6470 QQQ
LC-MS/MS analysis of Chlorates in Milk and Whey Powder using the Agilent 6470 QQQ Anthony Sullivan, LC/MS Product Specialist Melanie Mülek and Christoph Müller LC-MS Applications Specialists Hewlett-Packard-Str.
More informationPhenomenex roq QuEChERS Kits. Overview. Spinach Facts
Optimisation of LC/MS Analysis of Pesticide Residues in Food Products When Using QuEChERS Technique Phenomenex roq QuEChERS Kits Aman Sharma Phenomenex ANZ amans@phenomenex.com 1 2 Background Overview
More informationLC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined
ProteCol LC Columns - Exceed the limit A premium inert range of LC columns delivering optimal peak shape. ProteCol -G Glass lined ProteCol -P PEEK lined B C A D E F A Column end cap B PEEK frit housing
More informationProtein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates
Application Note Clinical Research Protein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates Authors Limian Zhao and Megan Juck Agilent Technologies, Inc. Abstract
More informationThermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific
Thermo Scientific GlycanPac AXR-1 Column Product Manual P/N: April, 2014 Part of Thermo Fisher Scientific Product Manual for GlycanPac AXR-1 Columns GlycanPac AXR-1, 1.9 µm, Analytical, 2.1 x 150 mm (P/N
More informationAlternative Method of Hybrid SPE Sample Preparation for High Recovery LC-MS Analysis of Pharmaceutical Compounds in Plasma
Alternative Method of Hybrid SPE Sample Preparation for High Recovery LC-MS Analysis of Pharmaceutical Compounds in Plasma Authors: Xiaoning Lu, and Michael Ye Presenter: Carmen T. Santasania Supelco/Sigma/Aldrich
More informationUsing Hydrophilic Interaction Chromatography (HILIC) for the Retention of Highly Polar Analytes
Using Hydrophilic Interaction Chromatography (HILIC) for the Retention of Highly Polar Analytes Eric S. Grumbach,, Diane M. Diehl and Jeffrey R. Mazzeo 2003 Waters Corp. Outline Introduction HILIC Definition
More informationSimultaneous Quantitative Analysis of Total Catecholamines and Metanephrines in Urine Using CLEAN UP CCX2 and LC-MS/MS
Simultaneous Quantitative Analysis of Total Catecholamines and Metanephrines in Urine Using CLEAN UP CCX2 and LC-MS/MS UCT Part Numbers CUCCX256 Clean Up CCX2 (C8 + Carboxylic Acid) 500mg / 6mL SPE Cartridge
More informationAnalysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column
Application Note Pharmaceutical and Food Testing Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column Author Lu Yufei Agilent Technologies, Inc. Abstract A liquid chromatographic
More informationTitle Revision n date
A. THIN LAYER CHROMATOGRAPHIC TECHNIQUE (TLC) 1. SCOPE The method describes the identification of hydrocortisone acetate, dexamethasone, betamethasone, betamethasone 17-valerate and triamcinolone acetonide
More informationHICHROM. Chromatography Columns and Supplies NEW PRODUCTS. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies NEW PRODUCTS Catalogue 9 1 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)118 930 3660 Fax: +44 (0)118 932 3484 Email: sales@hichrom.co.uk
More informationComprehensive Study of SLE as a Sample. Preparation Tool for Bioanalysis
Comprehensive Study of SLE as a Sample Preparation Tool for Bioanalysis Wan Wang, Warren Chen, Jerry Wang Bonna-Agela Technologies 179 Southern Street, West TEDA, Tianjin, China Abstract A simple, fast,
More informationHyperSep Dispersive SPE Products
HyperSep Dispersive SPE Products QuEChERS Products Convenient and effective approach for determining pesticide residues in fruit, vegetables and other foods QuEChERS Dispersive SPE Product Selection The
More informationRapid and Robust Detection of THC and Its Metabolites in Blood
Rapid and Robust Detection of THC and Its Metabolites in Blood Application Note Forensics/Doping Control Author Stephan Baumann Agilent Technologies, Inc. Santa Clara CA 95051 USA Abstract A robust method
More informationEU Priority PAH Analysis in Pumpkin Seed Oil Using Bond Elut EMR Lipid Cleanup by GC/MS/MS
Application Note Food Testing & Agriculture EU Priority PAH Analysis in Pumpkin Seed Oil Using Bond Elut EMR Lipid Cleanup by GC/MS/MS Authors Thorsten Bernsmann Chemisches und Veterinäruntersuchungsamt
More informationCHROMABOND HLB. Introduction. Advantages of CHROMABOND HLB. Technical data
MACHEREY-NAGEL Chromatography nhydrophilic-lipophilic balanced phase nenhanced retention for polar compounds nconsistent recoveries Introduction The enrichment of hydrophilic analytes from polar matrices
More informationDetermination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry
Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry Application Note Food Safety Authors Chenhao Zhai Agilent
More informationThe Ephedra Story: An Automated SPE Procedure and Analysis for the Determination of Ephedra and Ephedra-like Compounds in Dietary Supplements
The Ephedra Story: An Automated SPE Procedure and Analysis for the Determination of Ephedra and Ephedra-like Compounds in Dietary Supplements Application Note 215 Joan Stevens, PhD, Kirby Reed (Gilson,
More informationA New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis
A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis X. Liu, C. Pohl, Dionex Corporation, Sunnyvale, CA, USA ABSTRACT Although reversed-phase (RP) silica columns (e.g., C18 and
More informationSeparation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column
Diamond Analytics Technical Note: T131-1 Separation of Vitamin D and Vitamin D Metabolites on FLARE C1 MM (Mixed Mode) HPLC Column Introduction In this technical note, the versatility of the diamond-based
More informationDetermination of Pharmaceutical Residues in Bovine Milk via LC MS/MS Following Solid Phase Extraction
Determination of Pharmaceutical Residues in Bovine Milk via LC MS/MS Following Solid Phase Extraction Application Note FB0113 Keywords SPE (Solid Phase Extraction), Bovine Milk, JECFA (Joint FAO/WHO Expert
More informationSimultaneous Quantitative Analysis of Total Catecholamines and Metanephrines in Urine Using 500 MG CLEAN UP CCX2 and LC-MS/MS
Simultaneous Quantitative Analysis of Total Catecholamines and Metanephrines in Urine Using 500 MG CLEAN UP CCX2 and LC-MS/MS UCT Part Numbers: CUCCX256 - Clean-Up CCX2 (C8 + Carboxylic Acid) 500mg/6mL
More informationYMC HILIC Columns for Polar Analytes
YMC HILIC Columns for Polar Analytes Polar Analytes Advantages In general, reliable applications in HPLC require a minimum retention factor (k ) of 2. In the widely used reversed phase methods polar compounds
More informationDetermination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.
Page 1 of 10 Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection EPL-BAS Method No. 205G881B Method Summary: Residues of 6-CPA are
More informationA Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS
A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS By Shun-Hsin Liang and Frances Carroll Abstract Vitamin K₁ and K₂ analysis is typically complex and time-consuming because these
More informationEfficient Quantitative Analysis of THC and Metabolites in Human Plasma Using Agilent Captiva EMR Lipid and LC-MS/MS
Application Note Forensic Analysis Efficient Quantitative Analysis of THC and Metabolites in Human Plasma Using Agilent Captiva EMR Lipid and LC-MS/MS Authors Joan Stevens and Limian Zhao Agilent Technologies,
More informationRaptor HILIC-Si: Simplify the Switch to HILIC
Stationary Phase: Silica Selectivity Accelerated Raptor HILIC-Si: Simplify the Switch to HILIC Retain polar compounds without ion-pairing reagents. 2.7 µm Raptor core-shell particles provide the speed
More informationPurification - Flash Chromatography
SuperFlash Compound Purification Columns Optimal Design Cost effective, high performance disposable flash column specifically designed for flash chromatography. Excellent Separations Designed to deliver
More informationGlycanPac AXR-1 Columns
CHRMATGRAPHY GlycanPac AXR- Columns For High Resolution Glycan Analysis Product Specifications The Thermo Scientific GlycanPac AXR- columns are highperformance, silica-based HPLC columns for simultaneous
More informationColumns for HPLC. Columns for HPLC. Basic principles of preparative HPLC
Basic principles of preparative HPLC The efficiency of HPLC for separation of one or several components from a complex mixture makes HPLC an important technique for preparative purifications. The difference
More informationAgilent Captiva Sample Preparation Filtration Portfolio GAUGE THE DIFFERENCE FILTRATION CAN MAKE
Agilent Captiva Sample Preparation Filtration Portfolio GAUGE THE DIFFERECE FILTRATIO CA MAKE Longer column life Less system downtime Greater sample cleanliness Optimal instrument performance Your time
More informationThe Development of LC/MS Methods for Determination of MDMA (Ecstasy) and Metabolites in Biological Samples
WA20714 The Development of LC/MS Methods for Determination of MDMA (Ecstasy) and Metabolites in Biological Samples Michael S. Young and Kevin M. Jenkins Waters Corporation, 34 Maple Street, Milford, MA
More informationApplication Note. Author. Abstract. Introduction. Food Safety
Determination of β2-agonists in Pork with SPE eanup and LC-MS/MS Detection Using Agilent BondElut PCX Solid-Phase Extraction Cartridges, Agilent Poroshell 120 column and Liquid Chromatography-Tandem Mass
More informationAuthors. Abstract. Forensic Toxicology. Irina Dioumaeva, John M. Hughes Agilent Technologies, Inc.
SAMHSA-Compliant LC/MS/MS Analysis of 11-nor-9-carboxy-D 9 - Tetrahydrocannabinol in Urine with Agilent Bond Elut Plexa PCX and Agilent Poroshell 120 Application Note Forensic Toxicology Authors Irina
More informationIAM Chromatography. Introduction
IAM Chromatography IAM Drug Discovery Columns Introduction References: 1. Regis 1998-99 Chromatography Catalog A simple, rapid method to predict drug transport across biological barriers has been a long
More informationRaptor HILIC-Si: Simplify the Switch to HILIC
Stationary Phase: Silica Selectivity Accelerated Raptor HILIC-Si: Simplify the Switch to HILIC Retain polar compounds without ion-pairing reagents. 2.7 µm Raptor core-shell particles provide the speed
More informationExtraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis
Application Note AN782 Extraction of Multiple Mycotoxins from Grain Using ISOLUTE Myco Page 1 Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis This application
More informationQuEchERS Solid Phase Extraction
QuEchERS-------------------------------------------------------1 Solid Phase Extraction------------------------------------------9 Silica Based SPE -----------------------------------------------13 Non-Silica
More informationAnalysis of HMF by HPLC
COST Action 927 Training School Building Skills on the Analysis of Thermal Process Contaminants in Foods 22-26 October 2007, Ankara Analysis of HMF by HPLC Vural Gökmen O O OH Background O COOH O R 2 Carbonyl
More informationMass Directed Flash Chromatography by Biotage. Biotage Dalton Mass Detectors
Mass Directed Flash Chromatography by Biotage Biotage Dalton Mass Detectors Why Do Companies Around the World Choose the Biotage Approach to Flash Purification? As a pioneer of automated Flash purification,
More informationHPLC Analysis of Sugars
HPLC Analysis of Sugars Pre-Lab Exercise: 1) Read about HPLC, sugars and the experiment and its background. 2) Prepare a flowchart as appropriate for the lab exercise. 3) Note the various sugar concentrations
More informationMass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System
Application Note Food Testing and Agriculture Mass-Based Purification of Natural Product Impurities Using an Agilent 126 Infinity II Preparative LC/MSD System Authors Florian Rieck and Jörg Hippler Agilent
More informationEASI-EXTRACT FOLIC ACID Product Code: P81 / P81B
EASI-EXTRACT FOLIC ACID Product Code: P81 / P81B Immunoaffinity columns for use in conjunction with HPLC or LC-MS/MS. For in vitro use only. P81/V16/13.04.15 www.r-biopharm.com Contents Page Test Principle...3
More informationUltimate Core Performance to Maximize Your Investment
Thermo Scientific Accucore HPL olumns Phase Overview Ultimate ore Performance to Maximize Your Investment Phase Overview Founded on state-of-the-art ore Enhanced Technology and utilizing vast experience
More informationProbing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection INTRODUCTION
Probing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection Michael Jones Waters Corporation, Wilmslow, UK APPLICATION BENEFITS The ACQUITY Arc System is
More informationCorticosteroids. Optimizations. Jens Hinge Andersen. National Food Institute Danish Technical University
Corticosteroids Optimizations Jens Hinge Andersen National Food Institute Danish Technical University jhia@food.dtu.dk Optimizations - corticosteroids : Minimizing ion-suppression from bovine urin Liver:
More informationLiquid Chromatography Syringes
Liquid Chromatography Syringes Hamilton manufactures a complete range of high performance liquid chromatography (HPLC) syringes and thin layer chromatography (TLC) syringes. HPLC Syringes HPLC syringes
More informationAnalytical Method for 2, 4, 5-T (Targeted to Agricultural, Animal and Fishery Products)
Analytical Method for 2, 4, 5-T (Targeted to Agricultural, Animal and Fishery Products) The target compound to be determined is 2, 4, 5-T. 1. Instrument Liquid Chromatograph-tandem mass spectrometer (LC-MS/MS)
More informationTransfer and Speed-up of Methods to Fused-Core Particle Columns EPA Method 1694
Transfer and Speed-up of Methods to Fused-Core Particle Columns EPA Method 1694 Ed Mauney, Hillel K. Brandes, William H. Campbell, Wayne K. Way, Richard A. Henry, David S. Bell, and Carmen T. Santasania
More informationErgovaline. [Methods listed in the Feed Analysis Standards] 1 Liquid chromatography Note 1, 2 [Feed Analysis Standards, Chapter 5, Section 2
Ergovaline C 29 35 5 5 MW: 533.619 CAS o.: 2873-38-3 [Summary of ergovaline] Ergovaline is a kind of ergot alkaloids produced by endophytes eotyphodium coenophialum and eotyphodium lolli, symbionts of
More informationShuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W
Simple, Fast and Accurate Quantitation of Human Plasma Vitamins and Their Metabolites by Protein Precipitation Combined with Columns Using HPLC-UV, HPLC-FLD or LC/MS/MS Shuguang Li, Jason Anspach, Sky
More informationRapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit
Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit Application Note General Chromatography, Food Industry Authors John W. Henderson Jr., Judy Berry, Anne Mack, William Long Agilent
More informationIncreasing Extraction Efficiency of Wet Samples Using a Novel New Polymer During Accelerated Solvent Extraction
Increasing Extraction Efficiency of Wet Samples Using a Novel New Polymer During Accelerated Solvent Extraction SM Rahmat Ullah, Kannan Srinivasan, Chris Pohl, Pranathi Perati and Alexander Zhang Thermo
More informationUltra High Performance Liquid Chromatograph. Nexera X2 C196-E079
Ultra High Performance Liquid Chromatograph Nexera X2 C196-E79 Maximizing the Potential of UHPLC/HPLC Analyses Intelligence Intelligent data solutions, including a new i -PDeA peak calculation method for
More informationMycotoxin Analysis in Peanut Butter Using Captiva EMR Lipid Cleanup and LC/MS/MS
Application Note Food Testing & Agriculture Mycotoxin Analysis in Peanut Butter Using Captiva EMR Lipid Cleanup and LC/MS/MS Author Derick Lucas Agilent Technologies, Inc. Abstract Several countries regulate
More informationIC-MS Environmental Applications - Water Testing. Application Notebook
IC-MS Environmental Applications - Water Testing Application Notebook Table of Contents Environmental Sample Using IC-MS 3 Environmental Applications: Water Testing Acrylamide in Water 4 Trace Urea in
More informationOvercoming the Challenges of Sample Preparation and LC/MS/MS Method Development for Clinical Applications
Overcoming the Challenges of Sample Preparation and LC/MS/MS Method Development for Clinical Applications Speaker: Sky Countryman, Manager of PhenoLogix and Applied Technologies, Phenomenex Webinar Host:
More informationCalibration Standards
Calibration Standards/ Calibration Standards TSKgel standards polystyrene TSKgel standards poly(ethylene oxide) PStQuick polystyrene calibration standards TSKgel guard column products Fittings Pre-injector
More informationACE C18-AR Use the Power!
combines the retention and separation characteristics of a C18 phase with the extra selectivity of an integral phenyl functional group. The combination provides extra resolving power for a wide variety
More informationEASIMIP TM PATULIN Product Code: P250 / P250B
EASIMIP TM PATULIN Product Code: P250 / P250B Molecularly imprinted polymer columns for use in conjunction with HPLC. For in vitro use only. P250B/V5/03.09.18 www.r-biopharm.com Contents Page Test Principle...
More informationQuantitative Analysis of Opiates in Urine Using RRHT LC/MS/MS. Application. Authors. Introduction. Abstract. Forensics
Quantitative Analysis of piates in Urine Using RRHT LC/MS/MS Application Forensics Authors Sheher Mohsin Agilent Technologies, Inc. 10 N. Martingale Rd., Suite 550 Schaumburg, IL 60173 USA Yanan Yang Agilent
More informationSPME-LC Fibers for a Variety of Applications
SPME-LC Fibers for a Variety of Applications Robert Shirey 1, Craig Aurand 1, Dajana Vuckovic 2, Katherine Stenerson 1, Yong Chen 1, Leonard Sidisky 1, and Janusz Pawliszyn 2 1 Supelco, Div. of Sigma-Aldrich,
More informationPerformance Characteristics of the Agilent 1290 Infinity II Multicolumn Thermostat
Performance Characteristics of the Agilent 9 Infinity II Multicolumn Thermostat Technical Overview Author Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany Abstract This Technical Overview
More informationThe Nitrofurantoin Capsules Revision Bulletin supersedes the currently official monograph.
Nitrofurantoin Capsules Type of Posting Revision Bulletin Posting Date 28 Dec 2018 Official Date 01 Jan 2019 Expert Committee Chemical Medicines Monographs 1 Reason for Revision Compliance In accordance
More information