ABSTRACT /jp-journals Anuj Satija et al ORIGINAL RESEARCH

Size: px
Start display at page:

Download "ABSTRACT /jp-journals Anuj Satija et al ORIGINAL RESEARCH"

Transcription

1 ORIGINAL RESEARCH /jp-journals Evaluation of Salivary and Serum Concentration of Nickel and Chromium Ions in Orthodontic Patients and Their Possible Influence on Hepatic Enzymes: An in vivo Study 1 Anuj Satija, 2 Maninder Singh Sidhu, 3 Seema Grover, 4 Vikas Malik, 5 Puneet Yadav, 6 Rohan Diwakar ABSTRACT Objectives: The aims of present study were to evaluate nickel and chromium ions concentrations in salivary and serum samples from patients treated with fixed orthodontic appliances and their possible influences on hepatic enzymes. Materials and methods: Saliva and blood samples were collected from 36 patients ranging in age from 12 to 24 years. Three samples of saliva and two samples of blood were obtained. First saliva and blood samples were collected before inserting fixed appliances. Second salivary samples were collected at 1 week, third salivary sample and second blood sample after 4 weeks of appliance insertion. Serum was prepared by centrifuging blood samples at 3000 rpm for 10 minutes. Spectrophotometric determinations were carried out using electrothermal atomic absorption spectrophotometry. Results and conclusion: In serum, significant increase in Ni and Cr ion concentration occurred in samples collected after 4 weeks. In saliva samples, nickel and chromium reached their highest lavels in first week. Mean liver function enzymes SGOT and SGPT were also significantly increased in 4 weeks. Fixed orthodontic appliances release measurable amount of nickel and chromium when placed in mouth, but this increase does not reach toxic levels for nickel and chromium in saliva and serum to cause harmful effects in human beings. Keywords: Nickel, Chromium, Fixed orthodontics, Hepatic enzymes. How to cite this article: Satija A, Sidhu MS, Grover S, Malik V, Yadav P, Diwakar R. Evaluation of Salivary and Serum Concentration of Nickel and Chromium Ions in Orthodontic Patients and Their Possible Influence on Hepatic Enzymes: An in vivo Study. J Ind Orthod Soc 2014;48(4): Source of support: Nil Conflict of interest: None Received on: 11/7/14 Accepted after revision: 6/8/14 1,5,6 Senior Lecturer, 2 Professor and Head, 3 Professor, 4 Reader 1-6 Department of Orthodontics, SGT Dental College and Hospital, Gurgaon, Haryana, India Corresponding Author: Maninder Singh Sidhu, Professor and Head, Department of Orthodontics, SGT Dental College and Hospital, Gurgaon, Haryana, India, Phone: drmssidhu@hotmail.com INTRODUCTION During the last decade, there has been an increased interest among orthodontic professionals regarding side effects associated with use of biomaterials, especially metallic materials, such as gold, stainless steel, cobalt-chromium, nickel-titanium and beta-titanium. 1 Nickel-titanium alloys were introduced for use as orthodontic wires in 1970s 2 which contain 47 to 50% Ni and thus are the richest source of nickel among all alloys. 3 Oral environment is particularly ideal for the biodegradation of metals because of its ionic, thermal, microbiologic and enzymatic properties. 4 In oral environment, biodegradation of metals usually occurs by electrothermal breakdown. 5 The association of different metals in oral environment, where saliva is the connecting medium may produce electrogalvanic currents that produce discharge of ions and metallic components. Corrosion of alloys in the oral environment may decrease the strength of metallic appliances. 6 Discoloration on the underlying tooth surface during orthodontic treatment has also been regarded as one of the consequences of crevice corrosion of the bracket bases. 7 Nickel and chromium have dermatological, toxological and possibly mutagenic effects. 3 It is estimated that 4.5 to 28.5% of population have hypersensitivity to nickel with higher prevalence in females. 8 Chromium allergy is estimated at 10% in male subjects and 3% in female subjects. 9 Nickel hypersensitivity symptoms include rash, allergy, lung disorder, ear infection and tinnitus. Nickel is most common cause of metal induced allergic contact dermatitis in man and second in frequency is chromium. 9 In addition to the allergic issue, carcinogenic, mutagenic and cytotoxic effects have been assigned to nickel and to a lesser extent chromium. The most significant method for measurement of nickel release before and after onset of orthodontic treatment is salivary analysis, since it is the first diluents of the human body and allows long period of analyses. Also most of the redox reactions occur in liver and nickel is a redox active metal and is able to impair cellular defence mechanisms against peroxidation reactions. This is the first in vivo study relating salivary and serum levels of nickel and chromium to hepatic enzymes. It has been reported in literature increased serum level of nickel 518

2 JIOS Evaluation of Salivary and Serum Concentration of Nickel and Chromium Ions in Orthodontic Patients have been found to affect lungs, kidney, liver and heart. 10 Concentrations of serum nickel have been found to decrease in hepatic cirrhosis as a consequence of hypoalbuminemia. 11 Hence, present study was conducted to measure nickel and chromium ion concentrations in serum and saliva before and after insertion of orthodontic appliance and also to evaluate changes in salivary nickel and chromium ions concentration during orthodontic treatment and their possible influences the hepatic enzyme levels. The null hypothesis was that changes in salivary and serum nickel and chromium will not affect hepatic enzymes levels. MATERIALS AND METHODS This study was conducted at the Department of Orthodontics, SGT Dental College and Hospital, Gurgaon (India). The sample size consisted of 36 subjects (21 females and 15 males), who were to commence their fixed orthodontic treatment and had no history of having received any prior orthodontic appliance. The mean age of the sample was 17.5 years (14-24 years). An informed consent was obtained from all patients who participated in the study, and ethical clearance was obtained. The main criteria for subject inclusion were not that subjects should not be suffering from any systemic disease and should not have habits of smoking, red wine intake, excess of tea, coffee or betelnut, tobacco chewing and no amalgam restorations in oral cavity. Preadjusted edgewise appliance (ORMCO 0.022" MBT prescription) was used in all cases. All patients received 0.016" NiTi wire as an initial wire for alignment and leveling, which was tied into the bracket slot with stainless steel ligatures. None of the patients had palatal or lingual appliances welded to the bands or extraoral orthodontic appliances. Three samples of saliva were collected from each orthodontic patient. First sample before insertion of the fixed appliance which served as a baseline/reference level for salivary nickel and chromium content, second after 1 week, and third after 4 weeks of insertion of appliance. For the collection of saliva, patients initially rinsed the mouth thoroughly with a mouthful of deionized and distilled water. The patients, after an initial swallow were instructed to collect approximately 10 ml of saliva with mouth closed and released into the plastic test tube. In this way, approximately 10 ml of saliva was collected into an acid-washed (concentrated HNO 3 ) plastic test tube. After collection, the samples were stored in ice box at 20 C in dry ice until they were processed. Two samples of blood were collected from each orthodontic patient that is before insertion of fixed appliance which served as a baseline/reference level for serum nickel and chromium content and 4 weeks after insertion of the appliance. Blood was obtained from antecubital fossa of arm and centrifuged at 3000 rpm for 10 minutes in order to prepare serum. Preparation and Analysis of the Samples of Saliva and Blood For processing, 0.5 ml of saliva/serum was transferred to smaller plastic test tubes (Cryo Tubes, Polylabs, New Delhi) using a micro-pipette (Biochemical Ltd, Takson, India) which were pretested for not releasing nickel. For digestion of organic matter in saliva/serum, 0.15 ml of concentrated HNO 3 was added to each sample. The tubes were then closed and kept at 80 o C for 8 hours in hot air oven. The saliva samples were centrifuged at 3000 rpm for 2 minutes to settle particulate matter. The serum samples were centrifuged at 3000 rpm for 10 minutes to settle particulate matter (Fig. 1). The chemical analyses for nickel and chromium were done by electrothermal atomic absorption spectrometry (model AAS5 EA, Analytik Jena Ltd, Germany), at the Vimta Labs Ltd, Life Sciences Facility, Hyderabad, India (Fig. 2). Atomic absorption spectrometry (AAS) is an analytical technique that measures the concentrations of elements. The technique makes use of wavelengths of light specifically absorbed by an element. They correspond to energies needed to promote electrons from one energy level to higher energy level. The analytic lines used were nm for chromium and nm for nickel. Calibration Curve for Nickel and Chromium (Fig. 3) A calibration curve was used to determine the unknown concentration of an element (Ni, Cr) in a solution. A sample of known concentration of 20, 40, 60, 80, 100 ppm (obtained Fig. 1: Centrifuge machine The Journal of Indian Orthodontic Society, October-December 2014;48(4):

3 Fig. 2: Electrothermal atomic absorption spectrometry (model AAS5 EA, Analytik Jena Ltd, Germany), at the Vimta Labs Ltd, Life Sciences Facility, Hyderabad Fig. 3: The working of atomic absorption spectrometer Fig. 4: Xenon lamp as a continuous radiation source by diluting 1000 ppm standard solution from MERCK India) were subjected to and absorbance (Abs) values were plotted vs concentration levels. The calibration curve showed the concentration against the amount of radiation absorbed. If a linear calibration curve was obtained, the slope of calibration could be obtained by using following equation: A = mc (Beer-Lambert law) Absorbance = slope concentration Methodology and Determination of Concentration of Ni and Cr in Saliva and Serum Samples Twenty microliter of sample was injected directly into graphite tube (Analytik Jena Ltd, Germany) from an automated micropipette (Biochemical Ltd, India). The tube was heated electrically by passing a current of 5.0 milliamperes (mamp) through it in a pre-programed series of steps which included 15 seconds at 120 C to evaporate Graph 1: A normal calibration graph or calibration curve of nickel and chromium the solvent, 6 seconds at 950 o C to drive off any volatile organic material and change the sample to ash, and with a fast heating rate to 2100 o C for 5 seconds to vaporize and atomize the elements (Graph 1). Finally, tube was heated to higher temperature of 2300 o C to make it clean and keep it ready for next sample. Then a beam of electromagnetic radiation from a hollow cathode lamp (specific for Ni nm and Cr nm) (Fig. 4) was passed through the vaporized sample. Some of the radiation was absorbed by the metal atoms in the sample. The standard amount absorbed by metal atoms was compared with the calibration curve and this enables calculation of metal (Ni and Cr) concentration in unknown sample by using Beer-Lambert law: Concentration = (mg/l) Absorbance (recorded from AAS) Slope (calculated from calibration curve) 520

4 JIOS Evaluation of Salivary and Serum Concentration of Nickel and Chromium Ions in Orthodontic Patients Table 1: Salivary and serum Ni and Cr concentrations (ppb) in individual subjects at different time periods Salivary Ni Salivary Cr Serum Ni Serum Cr Pre 1 week 4 weeks Pre 1 week 4 weeks Pre 4 weeks Pre 4 weeks Mean Std. deviation Table 2: Paired t-test for salivary nickel and chromium (ppb) concentration N = 36 Mean Std. deviation t-value p-value Salivary Ni Pair 1 Pre <0.001* 1 week Pair 2 Pre <0.001* 4 weeks Pair 3 1 week <0.001* 4 weeks Salivary Cr Pair 1 Pre <0.001* 1 week Pair 2 Pre <0.001* 4 weeks Pair 3 1 week <0.001* 4 weeks *p < 0.001: Highly significant Table 3: Paired t-test for serum nickel and chromium (ppb) concentrations N = 36 Mean Std. deviation t-value p-value Serum nickel Pre <0.001* 4 weeks Serum chromium Pre <0.001* 4 weeks *p < 0.001: Highly significant SGOT pre(u/l) Table 4: Liver function enzyme levels (U/L) in individual subjects after 4 weeks SGOT 4 weeks (U/L) SGPT pre (U/L) SGPT 4 weeks (U/L) Alkaline phosphatase pre (U/L) Alkaline phosphatase 4 weeks (U/L) Mean Std. deviation RESULTS In this study, 36 subjects, mean age of 17.5 years, who were to commence their fixed orthodontic treatment and had no history of having received any prior orthodontic appliance, fixed or removable were selected. The sample distribution was divided into two groups. Table 1 shows that mean salivary nickel and chromium concentrations were increased in all patients after 1 week compared to baseline and 4 weeks levels. Hence, leaching of nickel and chromium ions from orthodontic wire, brackets and bands were maximum at 1 week when compared to baseline and 4 weeks levels. Also serum levels of nickel and chromium concentrations were increased in 4 weeks interval. Table 2 shows paired t-test for salivary nickel and chromium concentrations. Here, p-value in all three combination was <0.001, hence there was highly significant increase in observation taken at pretreatment and at 1 week, also deviation from pretreatment to 4 week was highly significant but this increase was not as high as at 1 week. The normal range for serum nickel have been reported to be between and ppb. The normal range for serum chromium are reported to be between and ppb. The Journal of Indian Orthodontic Society, October-December 2014;48(4):

5 Table 5: Paired t-test for SGOT, SGPT and alkaline phosphatase concentration N = 36 Mean Std. deviation t-value p-value SGOT Pre <0.001* 4 weeks SGPT Pre <0.001* Alkaline phosphatase *p < 0.001: Highly significant 4 weeks Pre <0.001* 4 weeks Table 3 shows paired t-test for serum nickel and chromium concentrations. The mean value for serum nickel ions for baseline level was ppb and for serum nickel 4 weeks levels was ppb. The mean value for serum chromium ions for baseline level was ppb and at 4 weeks levels was ppb. The p-value for baseline and 4 weeks was <0.001 which shows statistical significance difference. The normal range of SGOT concentrations varies from 18 to 45 U/L and normal range of SGPT concentrations varies from 28 to 49 U/L. Table 4 shows that SGOT and SGPT levels were increased in all patients at 4 weeks interval compared to baseline group, but they remain within normal range. The p-value for both at baseline and 4 weeks was <0.001 which was statistical significant. The normal range of alkaline phosphatase varies from 208 to 278 U/L. Alkaline phosphatase levels at 4 weeks were increased in all patients compared to baseline group, but they remained within normal range. The p-value at baseline and 4 weeks was <0.001 which was statistically significant. Table 5 shows paired t-test for SGOT, SGPT and alkaline phosphatase concentrations. Here p-value was <0.001, hence there was highly significant increase in observation taken at pretreatment to 4 weeks interval. DISCUSSION A wide variety of appliances and auxiliaries used in orthodontics contain nickel and chromium containing alloys, and thus they have become an integral part of almost every routine orthodontic intervention. 3 The potential health effects from exposure to these compounds have been scrutinized for more than 100 years, and sensitizing patients to these metals have been a concern. 12 Nickel has threshold concentration of approximately 30 ppm which may be sufficient to elicit a cytotoxic response. 13 Nickel has been found to induce DNA alterations mainly through base damage and DNA strand scission (single strand breaks), which are site specific. The mechanism of action of mutations caused by nickel is due to inhibition of several enzymes known to restore DNA breaks promoting microsatellite mutations and increasing total genomic methylation, thereby contributing to genetic instability. 14 Nickel toxicity has been reported in literature very well to the extent of death in few cases and postmortem report showed nickel level as µg/g wet weight 7.5 in blood, 47 in urine, 27 in liver, 60 in bile respectively. 15 In present study, saliva samples were obtained from orthodontic patients in order to analyze the release in the dynamic oral cavity environment. The main advantage of current in vivo study as compared to the in vitro studies was that the concentrations of salivary nickel and chromium were recorded in the natural oral environment of the patient, where the actual side effects of increased metal concentrations were going to take place. The present study when compared with study by Gjerdet et al 16, who conducted a study on nickel and iron in saliva of patients with fixed orthodontic appliances found no significant differences in absolute masses of nickel or iron in samples taken in saliva before, and 3 weeks after insertion of fixed appliances. But for samples taken immediately after 1 week, there was a significant increase in both concentrations and masses of nickel and iron. In the present study, there was a significant difference found between the pretreatment samples and the samples taken 1 and 4 weeks. Kerosuo et al 17 reported nickel release of 16.7 µg from a simulated fixed appliance and 7.5 µg from headgear during 7 days under static conditions. Grimsdottir et al 18 conducted an in vitro study and analyzed the release of nickel from different types of metal appliances immersed in physiologic saline and found that amount of metal release was highest from facebows followed by molar bands, brackets and archwires (NiTi). Petoumenou et al 19 concluded that samples taken immediately after placement of bands, brackets and NiTi archwires showed slight but significant increases in nickel concentration of 78 and 56 μg per liter respectively, compared with pretreatment value of 34 μg per liter. Nickel 522

6 JIOS Evaluation of Salivary and Serum Concentration of Nickel and Chromium Ions in Orthodontic Patients leaching occurred after placement of bands, brackets and NiTi archwires, associated with an increase of nickel ion concentration in patient s saliva and this effect decreased within 10 weeks. The range of serum nickel concentrations increased mainly from to ppb 4 weeks after insertion of fixed appliances (Table 3). There was a significant difference (p < 0.001) found between the no appliance samples and the samples taken 4 weeks after bonding and banding tested by the students t-test. The range of serum chromium concentration increased mainly from to ppb 4 weeks after insertion of fixed appliances (Table 3). There was a significant difference (p < 0.001) found between the pretreatment samples and the samples taken 4 weeks after bonding and banding tested by the students t-test. Nickel can be taken into the body by eating food, drinking water, or breathing air. Average dietary intake of nickel in adult persons is 165 µg/day but may reach 900 µg/day in diets rich in cocoa, oatmeal, nuts and soya products. 20,21 Only 1 to 5% of ingested nickel is absorbed in the body, remainder is excreted in the feces. About 5% of the amount ingested is absorbed into bloodstream through intestines, while 20 to 35% of inhaled nicked is absorbed through lungs. Total 68% of nickel reaching in blood is rapidly metabolized in liver and rest is excreted in urine, while 2% remains in kidneys with very short biological half-life of 0.2 days (about 5 hours). 22 The remaining 30% is evenly distributed to all remaining tissues of body, including the kidneys, liver and clears with a biological half-life of more than 3 years (1,200 days). Measurements of nickel concentrations in plasma from retired nickel refinery workers demonstrated that nickel was retained for several years after termination of nickel exposures. 23 Literature supports direct correlation of nickel concentrations in plasma and urine Also concentrations of serum nickel are decreased in hepatic cirrhosis, as a consequence of marked hypoalbuminia. Hepatic toxicity, manifested by microvesicular steatosis, transient diminution of hepatic glutathione concentration, increased activity of serum alkaline phosphatase, develops in nickel chloride treated rats. Also it has been reported inliterature that release of nickel in the first 6 months was higher than at rest of time periods. This could be attributed to maximum appliance degradation in the initial period of treatment. At the same time, nickel is more cathodic in nature which may be the cause of initial release of nickel and chromium. This is in correlation with the present study findings. As the deformation deactivates, though the oral environment remains same, the return of the material more towards normal stage causes gradual decrease in the release of nickel. 27 Urine and serum are the body fluids with widest utility as specimens for nickel analysis in biological monitoring programs. Hence, serum was used in the present study to find out possible systemic effects on liver by observing changes in SGOT, SGPT and alkaline phosphatase levels. Hence, we aimed to find out correlation between salivary and serum levels and further serum sample was used to find out changes in SGOT, SGPT and alkaline phosphatase levels to rule out any hepatic changes. The results of the present study also showed that there was a statistical difference in SGOT, SGPT and alkaline phosphatase concentrations before and 4 weeks after insertion of different fixed orthodontic appliances, but they remain within normal level. Natarajan 28 evaluated genotoxic effects of fixed appliances on oral mucosal cells and the relationship to nickel and chromium concentrations which was an in vivo study. The author concluded that nickel and chromium alloys of orthodontic appliances emit metal ions in sufficient quantities to induce localized genotoxic effects, but these changes revert on removal of appliances. Hafez 29 described cytotoxicity, genotoxicity, and metal release in patients with fixed orthodontic appliances, which was a longitudinal in vivo study. The author concluded that fixed orthodontic appliances decreased cellular viability, induced DNA damage, and increased the nickel and chromium contents of the buccal mucosa cells. Compared to control group, these changes were not evident at 6 months, possibly indicating tolerance for or repair of the cells and the DNA. There are very few studies in the literature showing systemic influences of Ni and Ti in orthodontic patients. Hence, future research should be carried for a longer period of time to study the effects of corrosion processes and mechanical phenomena, such as wear and fatigue on release of nickel and chromium in oral cavity. A larger sample size should also be used to eliminate the variability of results. CONCLUSION Following conclusions were drawn from the results of present study: The results indicate that orthodontic appliances corrode in oral environment and release nickel and chromium. Although, there is initial rise in salivary and serum nickel and chromium levels in 1 week but significantly tapered to permissible blood level in 4 weeks. Hence, this should The Journal of Indian Orthodontic Society, October-December 2014;48(4):

7 be taken care of in patients having allergy to nickel and chromium. Also, there was significant rise in hepatic enzymes level from baseline to 4 weeks but it was within normal range. REFERENCES 1. Eliades T, Zinelis S, Eliades G, Athanasiou AE. Nickel content of as received, retrieved, and recycled stainless steel brackets. Am J Orthod Dentofac Orthop 2002 Aug;122(2): Kocadereli I, Atac A, Kale S, Ozer D. Salivary nickel and chromium in patients with fixed orthodontic appliances. Angle Orthod 2000 Dec;70(6): Eliades T, Athanasiou AE. In vivo ageing of orthodontic alloys: implications for corrosion potential, nickel release, and biocompatibility. Angle Orthod 2002 Jun;72(3): Barrett RD, Bishara SE, Quinn JK. Biodegradation of orthodontic appliances, part I : biodegradation of nickel and chromium in vitro. Am J Orthod Dentofac Orthop 1993 Jan;103(1): Agaoglu G, Arun T, Izgu B, Yarat A. Nickel and chromium levels in the saliva and serum of patients with fixed orthodontic appliances. Angle Orthod 2001 Oct;71(5): Kerosuo H, Moe G, Hensten-Petterson. Salivary nickel and chromium in subjects with different types of fixed orthodontic appliances. Am J Orthod Dentofac Orthop 1997 Jun;111(6): Maijer R, Smith DC. Corrosion of orthodontic bracket bases. Am J Orthod 1982 Jan;81(1): Hwang C, Shin J, Cha J. Metal release from simulated fixed orthodontic appliances. Am J Orthod Dentofac Orthop 2001 Oct;120(4): Park HY, Shearer TR. In vitro release of nickel and chromium from simulated orthodontic appliances. Am J Orthod 1983 Aug; 84(2): Mcneely MD, Sunderman FW Jr, Nechay MW, Levine H. Abnormal concentrations of nickel in serum in cases of myocardial infarction, stroke, burns, hepatic cirrhosis and uremis. Clin Chem 1971 Nov;17(11): Sunderman FW Jr, Crisostomo C, Reid MC, Hopfer SM, Nomoto S. Rapid analysis of nickel in serum and whole blood by electrothermal atomic absorption spectrophotometry. Ann Clin Lab Sci 1984 May-Jun;14(3): Barrett RD, Bishara SE, Selim MI. Biodegradation of orthodontic appliances, part II changes in blood level of nickel. Am J Orthod Dentofac Orthop 1993 Feb;103(2): Rahilly G, Price N. Nickel allergy and orthodontics. J Orthod 2003 Jun;30(2): Eliades T, Trapalis C, Eliades G, Katsavrias E. Salivary metal levels of orthodontic patients: a novel methodological and analytical approach. Eur J Orthod 2003 Feb;25(1): Szathmary SC, Daldrup T. Determination of nickel by GC, GC-MS, and AAS in biological materials in a case of lethal poisoning. Fresenius Z Anal Chem 1982;313: Gjerdet NR, Erichsen ES, Remlo HE, Evjen G. Nickel and iron in saliva of patients with fixed orthodontic appliances. Acta Odontol Scand 1991 Apr;49(2): Kerosuo H, Moe G, Kleven E. In vitro release of nickel and chromium from different types of simulated orthodontic appliances. Angle Orthod 1995;65(2): Grimsdottir MR, Gjerdet NR, Hensten-Pettersen A. Composition and in vitro corrosion of orthodontic appliances. Am J Orthod Dentofac Orthop 1992 Jun;101(6): Petoumenou E, Arndt M, Keilig L, Hoederath H, Reimann S, Eliades T, Jager A, Bourauel C. Nickel concentration in the saliva of patients with nickel-titanium orthodontic appliances. Am J Orthod Dentofac Orthop 2009 Jan;135(1): Myron DR, Zimmerman TJ, Shuler TR, Klevay LM, Lee DE, Nielsen FH. Intake of nickel and vanadium of humans. A survey of selected diets. Am J Clin Nutr 1978 Mar;31(3): Grandjean P. Human exposure to nickel. In: Sunderman FW Jr, edition in chief, Nickel in the human environment, Lyon IARC; p Sunderman FW, Aitio A, Morgan L. Biological monitoring of nickel. Toxicol Ind Health 1986 Jul;2(1): Torjussen W, Andersen I. Nickel concentrations in nasal mucosa, plasma, and urine in active and retired nickel workers. Ann Clin Lab Sci 1979 Jul-Aug;9(4): Norseth T, Gundersen N. Urinary extraction of nickel as an index of nickel exposure. Ann Clin Lab Sci 1978;8: Zwennis WCM, Franssen AG. Exposure to insoluble nickel compounds in a plant for nickel catalysts. Relation between concentrations of nickel in urine and plasma. Abstr Second Intern Conf Clin Chem Clin Toxicol Metals Montreal 1983; Raithel HJ, Kress W, Schaller KH, Weltle D, Valentin H. Toxicological and occupational medical investigations concerning nickel-exposure in different industrial areas in the FRG. In: Brown SS, Sunderman FW Jr, editors. Progress in Nickel toxicology, Oxford, Blackwell, p Rai R, Shetty V, Ahluwalia R, George S. Quantitative assessment of serum nickel and chromium levels in orthodontic patients: an in vivo study. J Ind Orthod Soc 2011;45(4): Natarajan M, Padmanabhan S, Chitharanjan A, Narasimhand M. Evaluation of the genotoxic effects of fixed appliances on oral mucosal cells and the relationship to nickel and chromium concentrations: an in vivo study. Am J Orthod Dentofac Orthop 2011 Sep;140(3): Hafez HS, Selim EMN, Faten Hussein KE, Tawfik WA, Al-Ashkar EA, Mostafae YA. Cytotoxicity, genotoxicity, and metal release in patients with fixed orthodontic appliances: a longitudinal in vivo study. Am J Orthod Dentofac Orthop 2011 Sep;140(3):

An Accurate Methodology to detect Leaching of Nickel and Chromium Ions in the Initial Phase of Orthodontic Treatment: An in vivo Study

An Accurate Methodology to detect Leaching of Nickel and Chromium Ions in the Initial Phase of Orthodontic Treatment: An in vivo Study JCDP ORIGINAL RESEARCH Leaching 10.5005/jp-journals-10024-1828 of Nickel and Chromium Ions An Accurate Methodology to detect Leaching of Nickel and Chromium Ions in the Initial Phase of Orthodontic Treatment:

More information

Nickel and Chromium Ions Release from Stainless Steel Bracket Immersed in Fluoridated Mouthwash

Nickel and Chromium Ions Release from Stainless Steel Bracket Immersed in Fluoridated Mouthwash from Stainless Steel Bracket Immersed in Fluoridated Mouthwash Ida Bagus Narmada 1 *, Ria Anbar Baya 2, Thalca Hamid 3 1. Departement of Orthodontics, Faculty of Dental Medicine, Universitas Airlangga,

More information

Study Of Release Of Nickel And Chromium Ions From Different Brands Of Stainless Steel Brackets -An Invitro Study.

Study Of Release Of Nickel And Chromium Ions From Different Brands Of Stainless Steel Brackets -An Invitro Study. IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-83, p-issn: 2279-861.Volume 13, Issue 7 Ver. I (July. 21), PP 63-67 Study Of Release Of ckel And Chromium Ions From Different Brands

More information

Nickel and Cobalt Hypersensitive Reaction Before and After Orthodontic Therapy in Children

Nickel and Cobalt Hypersensitive Reaction Before and After Orthodontic Therapy in Children Nickel and Cobalt Hypersensitive Reaction Before and After Orthodontic Therapy in Children Abstract Nickel and cobalt are major components of alloys used in orthodontics. The objectives of this cross-sectional

More information

Comparative analysis of load/deflection ratios of conventional and heat-activated rectangular NiTi wires

Comparative analysis of load/deflection ratios of conventional and heat-activated rectangular NiTi wires Comparative analysis of load/deflection ratios of conventional and heat-activated rectangular NiTi wires Fabio Schemann-Miguel 1, Flávio Cotrim-Ferreira 2, Alessandra Motta Streva 3, Alexander Viégas de

More information

SELF LIGATING BRACKETS. 1. Commercial name: EasyClip EasyClip+ Lotus Self-ligating single buccal tubes

SELF LIGATING BRACKETS. 1. Commercial name: EasyClip EasyClip+ Lotus Self-ligating single buccal tubes PAGE 1 of 6 1. Commercial name: EasyClip EasyClip+ Lotus Self-ligating single buccal tubes 2. Manufacturer: Aditek do Brasil Ltda. Address: Cesário Mota, 14 ZIP: 14140-000 - Cravinhos SP - Brazil Phone:

More information

Research Article Absorption of Nickel, Chromium, and Iron by the Root Surface of Primary Molars Covered with Stainless Steel Crowns

Research Article Absorption of Nickel, Chromium, and Iron by the Root Surface of Primary Molars Covered with Stainless Steel Crowns Dentistry Volume 2010, Article ID 326124, 4 pages doi:10.1155/2010/326124 Research Article Absorption of Nickel, Chromium, and Iron by the Root Surface of Primary Molars Covered with Stainless Steel Crowns

More information

Instructions for use

Instructions for use 文件编号 AS-SM-04 版本号 A/2 Orthodontic Archwire 生效日期 2009-2-11 修订日期 2012-2-28 Instructions for use Manufacturer: Suite 1503, Lidu(NO1)Mansion, Lane #500 South Zhongshan Road Section 1,Shanghai200023,China whose

More information

ORTHODONTIC WIRES. 1. Commercial name: Contour NiTi Memoflex NiTi Cuper NiTi Stainless Steel TMA Archwire Sequence Springs

ORTHODONTIC WIRES. 1. Commercial name: Contour NiTi Memoflex NiTi Cuper NiTi Stainless Steel TMA Archwire Sequence Springs PAGE 1 of 6 1. Commercial name: Contour NiTi Memoflex NiTi Cuper NiTi Stainless Steel TMA Archwire Sequence Springs 2. Manufacturer: Aditek do Brasil Ltda. Address: Cesário Mota, 14 ZIP: 14140-000 - Cravinhos

More information

Simply Great Wire! Great prices.

Simply Great Wire! Great prices. 2017 CATALOG Simply Great Wire! Great prices. CONTENTS 2-4 NiTi Wires 5 Stainless Steel Wires 6-7 Archforms 8 Beta Titanium Molybdenum Wires 9 Wire Auxiliaries WWW.HIGHLANDMETALS.COM NiTi Wires SuperElastic

More information

wiirre e a a n n d d w wiirre e ffo orrms ms

wiirre e a a n n d d w wiirre e ffo orrms ms wire and wire forms wire and wire forms wire and wire forms Leone orthodontic wires are available in a range of alloys and different grades of elasticity and hardness to meet any therapeutic requirements.

More information

for Pedagogues and School Staff for Pedagogues and School Staff Joel Klein Chancellor

for Pedagogues and School Staff for Pedagogues and School Staff Joel Klein Chancellor for Pedagogues and School Staff for Pedagogues and School Staff Joel Klein Chancellor Toxicology Definition Toxicology is the study of the harmful effects of chemicals on biological systems 33 34 How do

More information

Toxicology. Toxicity. Human Health Concerns. Health Effects of Hazardous Materials

Toxicology. Toxicity. Human Health Concerns. Health Effects of Hazardous Materials Human Health Concerns Health Effects of Hazardous Materials Toxicology Study of the nature, effects, and detection of poisons in organisms Humans are obvious focal point Other species and ecosystem function

More information

Lead and Cadmium Levels in Some Commercially Available Local and Imported Peach Juice Samples in Alkoms City

Lead and Cadmium Levels in Some Commercially Available Local and Imported Peach Juice Samples in Alkoms City Human Journals Research Article September 2018 Vol.:13, Issue:2 All rights are reserved by Zaid M. Najah et al. Lead and Cadmium Levels in Some Commercially Available Local and Imported Peach Juice Samples

More information

Gentle-Jumper- Non-compliance Class II corrector

Gentle-Jumper- Non-compliance Class II corrector 15 CASE REPORT Gentle-Jumper- Non-compliance Class II corrector Amit Prakash 1,O.P.Mehta 2, Kshitij Gupta 3 Swapnil Pandey 4 Deep Kumar Suryawanshi 4 1 Senior lecturer Bhopal - INDIA 2 Professor Bhopal

More information

GAC Archwire Collection

GAC Archwire Collection GAC Archwire Collection All the Metal That Matters Copper to Nickel and All Points In-Between Your choice in archwires is a critical decision in your quest for excellence. GAC has been recognized as a

More information

HYCON DEVICE: A PRECISE AND CONTROLLED METHOD OF SPACE CLOSURE A CASE REPORT

HYCON DEVICE: A PRECISE AND CONTROLLED METHOD OF SPACE CLOSURE A CASE REPORT HYCON DEVICE: A PRECISE AND CONTROLLED METHOD OF SPACE CLOSURE A CASE REPORT Authors: Dr Arun Kumar G a Master of Dental Surgery(Orthodontics) Associate Professor, Department of Orthodontics & Dentofacial

More information

Galvanic Corrosion among Different Combination of Orthodontic Archwires and Stainless Steel Brackets

Galvanic Corrosion among Different Combination of Orthodontic Archwires and Stainless Steel Brackets Original Research Galvanic Corrosion among Different Combination of Orthodontic Archwires and Stainless Steel Brackets Farzin Heravi 1, Nima Mokhber 2, Elnaz Shayan 3 1 Dental Materials Research Center,

More information

INDICATIONS. Fixed Appliances are indicated when precise tooth movements are required

INDICATIONS. Fixed Appliances are indicated when precise tooth movements are required DEFINITION Fixed Appliances are devices or equipments that are attached to the teeth, cannot be removed by the patient and are capable of causing tooth movement. INDICATIONS Fixed Appliances are indicated

More information

Danville Family Dentist Dental Practice of Shailaja Singh DDS

Danville Family Dentist Dental Practice of Shailaja Singh DDS Danville Family Dentist Dental Practice of Shailaja Singh DDS The Facts About Dental Materials DENTAL BOARD OF CALIFORNIA 1432 Howe Avenue Sacramento, California 95825 www.dbc.ca.gov Dental Materials Fact

More information

Quality. Elegance. Innovation.

Quality. Elegance. Innovation. Quality. Elegance. Innovation. Triumph Orthodontic Instruments Quality and engineering come together for superior performance The Triumph Orthodontic Instrument line provides the orthodontic professional

More information

R J M E Romanian Journal of Morphology & Embryology

R J M E Romanian Journal of Morphology & Embryology Rom J Morphol Embryol 2015, 56(3):1119 1125 ORIGINAL PAPER R J M E Romanian Journal of Morphology & Embryology http://www.rjme.ro/ Assessment of orthodontic biomaterials cytotoxicity: an in vitro study

More information

CONVENTIONAL METAL BRACKETS AND AUXILIARY. 1. Commercial name: BioMax One Piece Vector Bionic Vector+ Tubos Ball Hook Stop Cleat Eyelet

CONVENTIONAL METAL BRACKETS AND AUXILIARY. 1. Commercial name: BioMax One Piece Vector Bionic Vector+ Tubos Ball Hook Stop Cleat Eyelet PAGE 1 of 5 1. Commercial name: BioMax One Piece Vector Bionic Vector+ Tubos Ball Hook Stop Cleat Eyelet 2. Manufacturer: Aditek do Brasil Ltda. Address: Cesário Mota, 14 ZIP: 14140-000 - Cravinhos SP

More information

INFLUENCE OF ARTIFICIAL SALIVA ON NiTi ORTHODONTIC WIRES: A STUDY ON THE SURFACE CHARACTERIZATION

INFLUENCE OF ARTIFICIAL SALIVA ON NiTi ORTHODONTIC WIRES: A STUDY ON THE SURFACE CHARACTERIZATION Materials Science, Vol. 47, No. 6, May, 2012 (Ukrainian Original Vol. 47, No. 6, November December, 2011) INFLUENCE OF ARTIFICIAL SALIVA ON NiTi ORTHODONTIC WIRES: A STUDY ON THE SURFACE CHARACTERIZATION

More information

The Facts About Fillings

The Facts About Fillings The Facts About Fillings DENTAL BOARD OF CALIFORNIA 1432 Howe Avenue Sacramento, California 95825 www.dbc.ca.gov Dental Materials Fact Sheet What About the Safety of Filling Materials? Patient health and

More information

Fillings: The Choices You Have

Fillings: The Choices You Have Fillings: The Choices You Have John Elias Baldacci, Governor Printed under appropriation #: 014-10A-2565-022 In accordance with Federal laws, the Maine Department of Human Services does not discriminate

More information

Galvanic Corrosion Behavior of Orthodontic Archwire Alloys Coupled to Bracket Alloys

Galvanic Corrosion Behavior of Orthodontic Archwire Alloys Coupled to Bracket Alloys Original Article Galvanic Corrosion Behavior of Orthodontic Archwire Alloys Coupled to Bracket Alloys Masahiro Iijima a ; Kazuhiko Endo b ; Toshihiro Yuasa c ; Hiroki Ohno d ; Kazuo Hayashi e ; Mitsugi

More information

ABSTRACT INTRODUCTION /jp-journals

ABSTRACT INTRODUCTION /jp-journals ORIGINAL RESEARCH 10.5005/jp-journals-10024-2102 An in vitro Evaluation of Friction Characteristics of Conventional Stainless Steel and Self-ligating Stainless Steel Brackets with different Dimensions

More information

Frictional Resistance in Various Ceramic Brackets using Archwires of different Alloys, Sizes and Cross sections: A Comparative Study

Frictional Resistance in Various Ceramic Brackets using Archwires of different Alloys, Sizes and Cross sections: A Comparative Study Research Article Frictional Resistance in Various Ceramic Brackets using Archwires of different Alloys, Sizes and Cross sections: Dr Yash Raj Bahadur. 1 Dr Deepak Kumar Agarwal, 2 Dr Ankur Gupta, 3 Dr

More information

The Facts About Fillings

The Facts About Fillings Dental Board of California 2005 Evergreen Street, Suite 1550 Sacramento CA 95815 www.dbc.ca.gov Dental Materials Fact Sheet What About the Safety of Filling Materials? Patient health and the safety of

More information

The Facts About Fillings

The Facts About Fillings Page 1 of 8 The Facts About Fillings DENTAL BOARD OF CALIFORNIA 1428 Howe Avenue Sacramento, California 95825 www.dbc.ca.gov Page 2 of 8 Dental Materials Fact Sheet What About the Safety of Filling Materials?

More information

A Severe Reaction to Ni-Containing Orthodontic Appliances

A Severe Reaction to Ni-Containing Orthodontic Appliances Case Report A Severe Reaction to Ni-Containing Orthodontic Appliances Olga Elpis Kolokitha a ; Evangelia Chatzistavrou b ABSTRACT Exposure to nickel-containing orthodontic appliances may cause intra- or

More information

Is nickel titanium superior to multistranded stainless steel wire in aligning crowded lower anteriors? A comparative in-vivo study.

Is nickel titanium superior to multistranded stainless steel wire in aligning crowded lower anteriors? A comparative in-vivo study. IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-0853, p-issn: 2279-0861. Volume 9, Issue 3 (Jul.- Aug. 2013), PP 47-51 Is nickel titanium superior to multistranded stainless steel

More information

FinTest IgG4 Screen 20 ELISA KIT

FinTest IgG4 Screen 20 ELISA KIT FinTest IgG4 Screen 20 ELISA KIT Cat. No.:DEIA6196 Pkg.Size:96T Intended use Enzyme immunoassay (microtiter strips) for the detection and the quantitative determination of IgG4 antibodies against 20 Food

More information

Chromium. Public Health Statement for CAS# September 2000

Chromium. Public Health Statement for CAS# September 2000 Public Health Statement for Chromium CAS# 7440-47-3 September 2000 This Public Health Statement is the summary chapter from the Toxicological Profile for Chromium. It is one in a series of Public Health

More information

The Loading And Unloading Properties Of Various Arch Wires As A Function Of Cross Sectional Dimension And Inter Bracket Span Width System

The Loading And Unloading Properties Of Various Arch Wires As A Function Of Cross Sectional Dimension And Inter Bracket Span Width System The Loading And Unloading roperties Of Various Arch Wires As A Function Of Cross Sectional Dimension And Inter Bracket Span Width System Authors: Thomas Mathew MDS Orthodontics, Lecturer, Faculty of Dentistry,

More information

Dual Force Cuspid Retractor

Dual Force Cuspid Retractor CLINICAL INNOVATION 1 Matrishva B Vyas, 2 Neeraj Alladwar ABSTRACT The most time consuming stage of bicuspid extraction-based treatment is cuspid retraction. Cuspid retraction with both types of conventional

More information

Comparative study of analytical method development of fluconazole in tablets and capsule by ultraviolet spectrophotometric method

Comparative study of analytical method development of fluconazole in tablets and capsule by ultraviolet spectrophotometric method Research Article Comparative study of analytical method development of fluconazole in tablets and capsule by ultraviolet spectrophotometric method Shital S. Patil*, Ubhale Ravindra, Yeole Tejal, Tayade

More information

RESEARCH ARTICLE /jp-journals

RESEARCH ARTICLE /jp-journals 10.5005/jp-journals-10021-1131 RESEARCH ARTICLE Parikshit Rajkumar Rao et al Evaluation and Comparison of Biomechanical Properties of Snail Loop with that of Opus Loop and Teardrop Loop for en masse Retraction

More information

ORTHODONTIC INSTRUMENTS

ORTHODONTIC INSTRUMENTS Swiss Quality and Reliability ORTHODONTIC INSTRUMENTS SWISS DENTAL SPECIALTIES Swiss Dental Specialties GmbH CH-6440 Brunnen Switzerland Phone +41 (0)41 810 42 42 Fax +41 (0)41 810 43 43 info@swissdentalspecialties.ch

More information

Acknowledgments Introduction p. 1 Objectives p. 1 Goals p. 2 History of Dental Materials p. 3 The Oral Environment p. 4 Characteristics of the Ideal

Acknowledgments Introduction p. 1 Objectives p. 1 Goals p. 2 History of Dental Materials p. 3 The Oral Environment p. 4 Characteristics of the Ideal Preface p. v Acknowledgments p. vii Introduction p. 1 Objectives p. 1 Goals p. 2 History of Dental Materials p. 3 The Oral Environment p. 4 Characteristics of the Ideal Dental Material p. 5 Quality Assurance

More information

A Comparison of Frictional Resistance between Active and Passive Self-ligating Brackets with Conventional Bracket Systems

A Comparison of Frictional Resistance between Active and Passive Self-ligating Brackets with Conventional Bracket Systems 10.5005/jp-journals-10015-1102 H ORIGINAL Jyothikiran et RESEARCH al A Comparison of Frictional Resistance between Active and Passive Self-ligating Brackets with Conventional Bracket Systems 1 H Jyothikiran,

More information

Correction of Crowding using Conservative Treatment Approach

Correction of Crowding using Conservative Treatment Approach Case Report Correction of Crowding using Conservative Treatment Approach Dr Tapan Shah, 1 Dr Tarulatha Shyagali, 2 Dr Kalyani Trivedi 3 1 Senior Lecturer, 2 Professor, Department of Orthodontics, Darshan

More information

Victory Series Active Self-Ligating Brackets. Reliable. and. Effective

Victory Series Active Self-Ligating Brackets. Reliable. and. Effective Victory Series Active Self-Ligating Brackets Reliable and Effective Victory Series Active Self-Ligating Brackets Reliability Victory Series SL Brackets are widely accepted as an industry benchmark for

More information

The Dental Board of California - Dental Materials Fact Sheet Adopted by the Board on October 17, 2001

The Dental Board of California - Dental Materials Fact Sheet Adopted by the Board on October 17, 2001 The Dental Board of California - Dental Materials Fact Sheet Adopted by the Board on October 17, 2001 As required by Chapter 801, Statutes of 1992, the Dental Board of California has prepared this fact

More information

Research Article Derivative Spectrophotometric Method for Estimation of Metformin Hydrochloride in Bulk Drug and Dosage Form

Research Article Derivative Spectrophotometric Method for Estimation of Metformin Hydrochloride in Bulk Drug and Dosage Form Research Article Derivative Spectrophotometric Method for Estimation of Metformin Hydrochloride in Bulk Drug and Dosage Form Gowekar NM, Lawande YS*, Jadhav DP, Hase RS and Savita N. Gowekar Department

More information

Material Safety Data Sheet

Material Safety Data Sheet Material Safety Data Sheet Section I. Product Identification and Uses Product Name 76333 Economy Silicone Mould Release CI# Synonyms DSL Chemical Name CAS # Chemical Formula Chemical mixture. Code 1515-03-003

More information

Experience with Contemporary Tip-Edge plus Technique A Case Report.

Experience with Contemporary Tip-Edge plus Technique A Case Report. IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-0853, p-issn: 2279-0861. Volume 13, Issue 3 Ver. I. (Mar. 2014), PP 12-17 Experience with Contemporary Tip-Edge plus Technique A Case

More information

MATERIAL SAFETY DATA SHEET Nickel Titanium SECTION 1 IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING

MATERIAL SAFETY DATA SHEET Nickel Titanium SECTION 1 IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING SECTION 1 IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING Product Name: Manufacturer: Address NiTi,, Black-Ti Wire Ultimate Wireforms, Inc. 200 Central Street Bristol, CT 06010

More information

ISSN (Print), ISSN (online) 1 Okeke O.R. and 2 Okeke M.U.

ISSN (Print), ISSN (online) 1 Okeke O.R. and 2 Okeke M.U. ESTIMATION OF THE DIETARY INTAKES OF HEAVY METALS BY CHILDREN, ADOLESCENTS, ADULTS AND SENIORS CONSUMING CHICKEN MEATS WITHIN AWKA AND ENUGU METROPOLIS AND ITS ENVIRONS. 1 Okeke O.R. and 2 Okeke M.U. 1

More information

Perception of pain and discomfort from three different types of orthodontic separators

Perception of pain and discomfort from three different types of orthodontic separators 2018; 4(9): 172-178 ISSN Print: 2394-7500 ISSN Online: 2394-5869 Impact Factor: 5.2 IJAR 2018; 4(9): 172-178 www.allresearchjournal.com Received: 05-07-2018 Accepted: 07-08-2018 Dr. Sangeeta Yadav Department

More information

5. BIOCHEMICAL COMPOSITION AND FOOD VALUE OF RIBBON FISH L. SAVALA

5. BIOCHEMICAL COMPOSITION AND FOOD VALUE OF RIBBON FISH L. SAVALA 5. BIOCHEMICAL COMPOSITION AND FOOD VALUE OF RIBBON FISH L. SAVALA During present study, sixty specimens of fresh L. savala ranging from 200 to 600 mm of total length were collected from Baithkol, Majali

More information

Mollenhauer Aligning Auxiliary for Bodily Alignment of Blocked-out Lateral Incisors in Preadjusted Edgewise Appliance Therapy

Mollenhauer Aligning Auxiliary for Bodily Alignment of Blocked-out Lateral Incisors in Preadjusted Edgewise Appliance Therapy Original Research 10.5005/jp-journals-10021-1237 Mollenhauer Aligning Auxiliary for Bodily Alignment of Blocked-out Lateral Incisors in Preadjusted Edgewise Appliance Therapy 1 Sreekrishnan B Nair, 2 AT

More information

Evaluation of Serum Copper and Zinc Levels in Betel Quid Associated Oral Submucous Fibrosis and Oral Squamous Cell Carcinoma Patients

Evaluation of Serum Copper and Zinc Levels in Betel Quid Associated Oral Submucous Fibrosis and Oral Squamous Cell Carcinoma Patients Original Article Evaluation of Serum Copper and Zinc Levels in Betel Quid Associated Oral Submucous Fibrosis and Oral Squamous Cell Carcinoma Patients Su Mon Than*, Sein Shwe**, Zaw Moe Thein**, Swe Swe

More information

INSTRUCTIONS FOR USE AND CARE

INSTRUCTIONS FOR USE AND CARE DIAMONDS INSTRUCTIONS FOR USE AND CARE DIAMONDS, MULTI-USE, FRICTION GRIP Quala Diamonds are a rotary cutting device made of stainless steel and coated with diamond particles on the working end. It is

More information

Admixtures for concrete, mortar and grout Test methods Part 12: Determination of the alkali content of admixtures

Admixtures for concrete, mortar and grout Test methods Part 12: Determination of the alkali content of admixtures KENYA STANDARD KS 2177: 2017 Kenya Standard KS 2769-12:2018 Admixtures for concrete, mortar and grout Test methods Part 12: Determination of the alkali content of admixtures KEBS 2018 First Edition 2018

More information

Treatment of Class II, Division 2 Malocclusion with Miniscrew Supported En-Masse Retraction: Is Deepbite Really an Obstacle for Extraction Treatment?

Treatment of Class II, Division 2 Malocclusion with Miniscrew Supported En-Masse Retraction: Is Deepbite Really an Obstacle for Extraction Treatment? TURKISH JOURNAL of DOI: 10.5152/TurkJOrthod.2017.17034 CASE REPORT Treatment of Class II, Division 2 Malocclusion with Miniscrew Supported En-Masse Retraction: Is Deepbite Really an Obstacle for Extraction

More information

A randomized clinical trial to compare three methods of orthodontic space closure

A randomized clinical trial to compare three methods of orthodontic space closure Journal of Orthodontics, Vol. 29, 2002, 31 36 SCIENTIFIC SECTION A randomized clinical trial to compare three methods of orthodontic space closure V. Dixon, M. J. F. Read, K. D. O Brien, H. V. Worthington

More information

essentialstm cutting your consumable costs brackets tubes wires springs instruments T:

essentialstm cutting your consumable costs brackets tubes wires springs instruments T: 2017 essentialstm cutting your consumable costs brackets tubes wires springs instruments T: W: www.tocdental.com www.tocdental.com 1 Value Stainless Steel Brackets Manufactured from advanced 17-4 stainless

More information

IJRPC 2011, 1(4) Rohan et al. ISSN: INTERNATIONAL JOURNAL OF RESEARCH IN PHARMACY AND CHEMISTRY

IJRPC 2011, 1(4) Rohan et al. ISSN: INTERNATIONAL JOURNAL OF RESEARCH IN PHARMACY AND CHEMISTRY INTERNATIONAL JOURNAL OF RESEARCH IN PHARMACY AND CHEMISTRY Available online at www.ijrpc.com Research Article ABSORPTION CORRECTION METHOD AND SIMULTANEOUS EQUATION METHOD FOR THE SIMULTANEOUS ESTIMATION

More information

Sliding mechanics in an extraction case treated with 3M Clarity ADVANCED Ceramic Brackets and the 3M MBT Appliance System.

Sliding mechanics in an extraction case treated with 3M Clarity ADVANCED Ceramic Brackets and the 3M MBT Appliance System. SM 3M Health Care Academy Sliding mechanics in an extraction case treated with 3M Clarity ADVANCED Ceramic Brackets and the 3M MBT Appliance System. Dr. Gianluigi Fiorillo Dr. Gianluigi Fiorillo received

More information

Anchorage system. tomas / Sets Page 270 tomas / Pins Page 271 Instruments and accessories Page 273 Patient consultation material Page 282

Anchorage system. tomas / Sets Page 270 tomas / Pins Page 271 Instruments and accessories Page 273 Patient consultation material Page 282 tomas / Sets Page 270 tomas / Pins Page 271 Instruments and accessories Page 273 Patient consultation material Page 282 266 . innovative comprehensive efficient. Dentaurum Online Shop shop.dentaurum.com

More information

Cotinine (Mouse/Rat) ELISA Kit

Cotinine (Mouse/Rat) ELISA Kit Cotinine (Mouse/Rat) ELISA Kit Catalog Number KA2264 96 assays Version: 03 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Intended Use... 3 Background... 3 Principle

More information

The Rondeau System. Brackets, Bands, Buccal Tubes and Archwires. Orthodontic supplies recommended by Dr. Brock Rondeau

The Rondeau System. Brackets, Bands, Buccal Tubes and Archwires. Orthodontic supplies recommended by Dr. Brock Rondeau The Rondeau System Brackets, Bands, Buccal Tubes and Archwires Orthodontic supplies recommended by Dr. Brock Rondeau Achieve Consistently Accurate Placement The Di-MIM Mini-Twin Bracket s rhomboid shape

More information

New York Science Journal 2015;8(5) The Environmental Effects of Amalgam Tooth Fillings

New York Science Journal 2015;8(5)   The Environmental Effects of Amalgam Tooth Fillings The Environmental Effects of Amalgam Tooth Fillings Abdulsalam. I. Rafida 1, Abdulhmid.M. Alkout 1 and Abdultif. M. Alroba 2 1 Tripoli University Faculty of medical Technology, Tripoli, Libya 2 Department

More information

Aspartame Material Safety Data Sheet

Aspartame Material Safety Data Sheet Newseed Chemical Co., Limited Material Safety Data Sheet MSDS SECTION 1- PRODUCT AND MANUFACTURER IDENTIFICATION Product Name: Manufacturer: Manufacturer s Address: China manufacturer Telephone: Fax: SECTION

More information

An estimated 25-30% of all orthodontic patients can benefit from maxillary

An estimated 25-30% of all orthodontic patients can benefit from maxillary 2017 JCO, Inc. May not be distributed without permission. www.jco-online.com A New Appliance for Efficient Molar Distalization VAIBHAV GANDHI, BDS, MDS FALGUNI MEHTA, BDS, MDS HARSHIK PAREKH, BDS, MDS

More information

SAFETY DATA SHEET. Great Lakes Orthodontics 200 Cooper Ave Tonawanda, NY CHEMTREC:

SAFETY DATA SHEET. Great Lakes Orthodontics 200 Cooper Ave Tonawanda, NY CHEMTREC: SAFETY DATA SHEET SECTION 1. INDENTIFICATION Great Lakes Orthodontics 200 Cooper Ave Tonawanda, NY 14150 716-871-1161 800-828-7626 CHEMTREC: 800-424-9300 Product Name: Silver Solder Product Number: 240-001,

More information

GREAT LAKES BRACKETS. Treat with Quality. Treat with Confidence.

GREAT LAKES BRACKETS. Treat with Quality. Treat with Confidence. GREAT LAKES BRACKETS Treat with Quality. Treat with Confidence. BRACKET SYSTEMS DESIGNED BY ORTHODONTISTS, FOR ORTHODONTISTS, GREAT LAKES BRACKETS DELIVER. EVERY SINGLE BRACKET IS HAND INSPECTED AND ENGINEERED

More information

Efficient Bonding Protocol for the Insignia Custom Bracket System

Efficient Bonding Protocol for the Insignia Custom Bracket System Efficient Bonding Protocol for the Insignia Custom Bracket System Abstract The Insignia appliance is reverse-engineered from a digital set-up of the prescribed dental alignment. Each bracket configuration,

More information

Instruments Summary. Orthodontic Products - Catalog 03

Instruments Summary. Orthodontic Products - Catalog 03 03 Instruments Instruments Summary Hu-Friedy Instruments 167 Distal end cutters 168 Cutters 168 Utility pliers 169 Lingual pliers 170 Forming pliers 171 Instruments 172 Holders 173 Mosquito and Mathieu

More information

A New Fixed Interarch Device for Class II Correction

A New Fixed Interarch Device for Class II Correction A New Fixed Interarch Device for Class II Correction WILLIAM VOGT, DDS Fixed devices are increasingly being used for molar distalization in Class II treatment because they eliminate the need for special

More information

SAFETY DATA SHEET In accordance with REACH Regulation EC No.1907/2006

SAFETY DATA SHEET In accordance with REACH Regulation EC No.1907/2006 Page 1 ( 8 ) (13/05/2015) Section 1. Identification of the substance or the mixture and of the supplier 1.1 Product Identifier Product identifier: Other identifiers: (Contains:ALPHA-ISOMETHYL IONONE, METHYL

More information

The Dental Board of California Dental Materials Fact Sheet Adopted by the Board on October 17, 2001

The Dental Board of California Dental Materials Fact Sheet Adopted by the Board on October 17, 2001 The following document is the Dental Board of California s Dental Materials Fact Sheet. The Department of Consumer Affairs has no position with respect to the language of the Dental Materials Fact Sheet;

More information

Tahereh Hosseinzadeh Nik 1, Tabassom Hooshmand 2*, Habibeh Farazdaghi 3, Arash Mehrabi 1 and Elham S Emadian Razavi 1

Tahereh Hosseinzadeh Nik 1, Tabassom Hooshmand 2*, Habibeh Farazdaghi 3, Arash Mehrabi 1 and Elham S Emadian Razavi 1 Hosseinzadeh Nik et al. Progress in Orthodontics 2013, 14:48 RESEARCH Open Access Effect of chlorhexidine-containing prophylactic agent on the surface characterization and frictional resistance between

More information

SAFETY DATA SHEET Waffle Belgian Flavor

SAFETY DATA SHEET Waffle Belgian Flavor Section. Identification of the substance or the mixture and of the supplier Product Code: Product Name: Trade Name: Company Name: Web site address: 34583 Vapor Vapes, Inc 80 Catalina St, Seaside, CA 93955

More information

An Innovative Treatment Approach with Atypical Orthodontic Extraction Pattern in Bimaxillary Protrusion Case

An Innovative Treatment Approach with Atypical Orthodontic Extraction Pattern in Bimaxillary Protrusion Case 10.5005/jp-journals-10021-1127 CASE REPORT An Innovative Treatment Approach with Atypical Orthodontic Extraction Pattern in Bimaxillary Protrusion Case 1 Anil Miglani, 2 Reena R Kumar, 3 Ashish Chopra,

More information

Problem Based Practical Activities Problem 10: Patient prognosis

Problem Based Practical Activities Problem 10: Patient prognosis Learn Chemistry Problem Based Practical Activities Developed by Dr Catherine Smith, RSC School Teacher Fellow at the University of Leicester 2011-2012 This resource was produced as part of the National

More information

S A F E T Y D A T A S H E E T

S A F E T Y D A T A S H E E T S A F E T Y D A T A S H E E T C l a s s i c 1 0 0 G e l F l u x DATE REVISED: July 27, 2016 Product Name: Classic 100 Gel Flux Manufacturer: Stellar Technical Products 707 E. Gardena Blvd., Gardena, CA

More information

Smoking and Nicotine Replacement Therapy (NRT) Lec:5

Smoking and Nicotine Replacement Therapy (NRT) Lec:5 Smoking and Nicotine Replacement Therapy (NRT) Lec:5 Tobacco use remains the single largest preventable cause of mortality. Cigarette smoke is a complex mixture of an estimated 4800 compounds. Approximately

More information

Valeri Petrov 1, Ivana Ilievska 2, Laura Andreeva 1, Valdek Mikli 3, Andrzej Zaleski 4, Angelina Stoyanova-Ivanova 2

Valeri Petrov 1, Ivana Ilievska 2, Laura Andreeva 1, Valdek Mikli 3, Andrzej Zaleski 4, Angelina Stoyanova-Ivanova 2 DOI: 10.18044/Medinform.201741.559 Studying the Effects of Autoclaving Process on Orthodontic Archwires Valeri Petrov 1, Ivana Ilievska 2, Laura Andreeva 1, Valdek Mikli 3, Andrzej Zaleski 4, Angelina

More information

Aesthetic Brackets and Accessories

Aesthetic Brackets and Accessories Aesthetic Brackets and Accessories Our Strength is our Service Ortho-Care s version of the MBT prescription shown in this chapter is not claimed to be a duplication, and does not in any way imply endorsement

More information

SAFETY DATA SHEET. In accordance with 29 CFR Section 1. Identification of the substance or the mixture and of the supplier

SAFETY DATA SHEET. In accordance with 29 CFR Section 1. Identification of the substance or the mixture and of the supplier Page ( 8 Issue date: /30/206 (/30/206 Section. Identification of the substance or the mixture and of the supplier. Product Identifier Product identifier: Other identifiers: None.2 Relevant identified uses

More information

The Tip-Edge appliance and

The Tip-Edge appliance and Figure 1: Internal surfaces of the edgewise archwire slot are modified to create the Tip-Edge archwire slot. Tipping surfaces (T) limit crown tipping during retraction. Uprighting surfaces (U) control

More information

An In-vitro Comparison of Force Loss of Orthodontic Non-Latex Elastics

An In-vitro Comparison of Force Loss of Orthodontic Non-Latex Elastics Original Article An In-vitro Comparison of Force Loss of Orthodontic Non-Latex Elastics Shiva Alavi 1, Atusa Rahnama Tabatabaie 2, Fatemeh Hajizadeh 3, Alireza Haerian Ardekani 4 1 Associate Professor,

More information

The Efficacy of Low-level Laser Therapy on Pain caused by Placement of the First Orthodontic Archwire: A Clinical Study

The Efficacy of Low-level Laser Therapy on Pain caused by Placement of the First Orthodontic Archwire: A Clinical Study Javeriya Nahin et al ORIGINAL RESEARCH 10.5005/jp-journals-10024-2282 The Efficacy of Low-level Laser Therapy on Pain caused by Placement of the First Orthodontic Archwire: A Clinical Study 1 Javeriya

More information

IDQ Operating, Inc. 44 Old Ridgebury Road Suite 300 Danbury, CT Tel Product And Company Identification

IDQ Operating, Inc. 44 Old Ridgebury Road Suite 300 Danbury, CT Tel Product And Company Identification 1. Product And Company Identification Product Name: Responsible Party: IDQ GPL-5 Information Phone Number: +1 203-205-2900 Emergency Phone Number: For Medical Emergencies, call 1-866-949-6465 / +1 303-389-1332

More information

Dental Materials Journal 2015; 34(3): Keisuke TOCHIGI, Souichiro ODA and Kazuhito ARAI INTRODUCTION

Dental Materials Journal 2015; 34(3): Keisuke TOCHIGI, Souichiro ODA and Kazuhito ARAI INTRODUCTION Dental Materials Journal 2015; 34(3): 388 393 Influences of archwire size and ligation method on the force magnitude delivered by nickel-titanium alloy archwires in a simulation of mandibular right lateral

More information

ORTHOdontics SLIDING MECHANICS

ORTHOdontics SLIDING MECHANICS ORTHOdontics PGI/II SLIDING MECHANICS FOCUS ON TARGETED SPACE GAINING AND ITS APPLICATIONS, INCLUDING WITH RAPID PALATAL EXPANDIONS. ALSO INCLUDES RETENTION AND CLINICAL PEARLS FACULTY: Joseph Ghafari,

More information

Effect of Sodium Fluoride Mouthwash on the Frictional Resistance of Orthodontic Wires

Effect of Sodium Fluoride Mouthwash on the Frictional Resistance of Orthodontic Wires Original Article Effect of Sodium Fluoride Mouthwash on the Frictional Resistance of Orthodontic Wires Allahyar Geramy 1, Tabassom Hooshmand 2, Tahura Etezadi 3 1 Professor, Dental Research Center, Dentistry

More information

dental fillings facts About the brochure:

dental fillings facts About the brochure: dental fillings facts About the brochure: Your dentist is dedicated to protecting and improving oral health while providing safe dental treatment. This fact sheet provides information you need to discuss

More information

Supplementary materials for manuscript entitled Development and Analytical

Supplementary materials for manuscript entitled Development and Analytical Supplementary materials for manuscript entitled Development and Analytical Validation of An Enzyme-Linked Immunosorbent assay (ELISA) for the detection of Copper in Human Hair and Serum Samples Manuscripte

More information

Test Name Results Units Bio. Ref. Interval

Test Name Results Units Bio. Ref. Interval 135091357 Age 32 Years Gender Female 7/9/2017 120000AM 7/9/2017 71849M 8/9/2017 31537M Ref By Final METAL SCREEN 3, URINE - ARSENIC,CADMIUM,CHROMIUM,COBALT, COER, LEAD, MANGANESE, MERCURY, NICKEL, SELENIUM,

More information

H312: Harmful in contact with skin. H319: Causes serious eye irritation. H351: Suspected of causing cancer.

H312: Harmful in contact with skin. H319: Causes serious eye irritation. H351: Suspected of causing cancer. Safety Data Sheet Date Issued: 5/18/2017 SECTION 1: IDENTIFICATION OF THE PREPARATION AND THE COMPANY PRODUCT NAME: Urinal Screen W/ Para Block (Cherry) RECOMMENDED USE: Deodorizer RESTRICTIONS ON USE:

More information

An Effectiv Rapid Molar Derotation: Keles K

An Effectiv Rapid Molar Derotation: Keles K An Effectiv ective e and Precise Method forf Rapid Molar Derotation: Keles K TPA Ahmet Keles, DDS, DMSc 1 /Sedef Impar, DDS 2 Most of the time, Class II molar relationships occur due to the mesiopalatal

More information

Pulpdent Corporation Revision Date: May 7, 2014

Pulpdent Corporation Revision Date: May 7, 2014 1.0 Commercial Product Name and Supplier 1.1 Commercial product name / designation 1.2 1.2.2 Application / Use SIC 1.2.3 Use Category 1.3 Manufacturer Pulpdent Corporation 80 Oakland Street, P.O. Box 780

More information

Torque efficiency of different archwires in and inch conventional brackets

Torque efficiency of different archwires in and inch conventional brackets Original Article Torque efficiency of different archwires in 0.018- and 0.022-inch conventional brackets Iosif Sifakakis a ; Nikolaos Pandis b ; Margarita Makou c ; Theodore Eliades d ; Christos Katsaros

More information

Glass Packaging Issues with PET. Key Features Inert and chemically inactive Pure and safe

Glass Packaging Issues with PET. Key Features Inert and chemically inactive Pure and safe An ISO 9001:2008 Company Made from nontoxic raw materials - sand, soda ash, limestone, and up to 70 percent recycled glass or cullet - glass is the only packaging material accepted worldwide as generally

More information

Changes in Lip, Cheek, and Tongue Pressures After Rapid Maxillary Expansion Using a Diaphragm Pressure Transducer

Changes in Lip, Cheek, and Tongue Pressures After Rapid Maxillary Expansion Using a Diaphragm Pressure Transducer Original Article Changes in Lip, Cheek, and Tongue Pressures After Rapid Maxillary Expansion Using a Diaphragm Pressure Transducer Nazan Küçükkeleş, DDS, PhD a ; Cenk Ceylanoğlu, DDS b Abstract: The purpose

More information

EN Instructions for Use GC Orthodontics Line

EN Instructions for Use GC Orthodontics Line EN GC Orthodontics Line For use only by a dental professional in the recommended indications. 1. Intended Use GC Orthodontics Line is a system for orthodontic corrections. The system consists of brackets,

More information