Comparative analyses of paediatric dental measurements using plaster and three-dimensional digital models
|
|
- Beverley Perry
- 6 years ago
- Views:
Transcription
1 Y. Kaihara*, A. Katayama**, K. Ono**, M. Kurose**, K. Toma**, H. Amano***, H. Nikawa**, K. Kozai**** Hiroshima University, Hiroshima, Japan *Department of Paediatric Dentistry, Hiroshima University Hospital **Department of Oral Biology and Engineering, Division of Oral Health Sciences, Graduate School of Biomedical Sciences ***Maxillofacial Functional Development Division of Oral Health Sciences, Graduate School of Biomedical Sciences ****Department of Paediatric Dentistry, Division of Cervico-Gnathostomatology Graduate School of Biomedical Sciences Comparative analyses of paediatric dental measurements using plaster and three-dimensional digital models abstract Aim Recent advances in three-dimensional imaging have led to an increased interest in the application of computer-models in paediatric dentistry. However, in evidence-based paediatric dentistry the accuracy of new methods must be validated before they are introduced to clinical practice. We aimed to compare the accuracy of measurements of digital models obtained using a noncontact 3D measuring system, with direct measurements made on plaster models (gold standard) from children. Materials and methods Twelve pairs of plaster models were obtained from children with deciduous dentition; tooth size, arch width, and arch length were examined. The same parts on each cast were measured twice with at least a 2-week interval between measurements with each method by four examiners. Linear mixed-effects model analyses were performed for comparison of values from the 2 different measurement methods. Results The average difference between the 2 methods in measured values, derived from the final model, was <0.2 mm. Random effect of examiners was always the smallest component of variance, and frequently negligible. Statistics: Intraclass correlation coefficients were typically >90%. Conclusion These results suggest that primary dentition analysis of digital models has a high accuracy level, comparable to that of direct measurement of plaster models by digital calipers. Keywords Accuracy; Non-contact 3D laser scanner; Study model analysis. Introduction Guidance of eruption and development of dentition and occlusion are important paediatric dental interventions. Early diagnosis and successful treatment during childhood contribute not only to the prevention of the development of malocclusions but also to the promotion of the normal development of dental arches and jaw function. In order to predict occlusal development, it is necessary to observe patient dentition and occlusion from the primary dentition period. Study model analysis is an essential component of the assessment of occlusion, diagnosis, treatment planning, and evaluation. Traditionally, the gold standard for obtaining diagnostic measurements involves the use of plaster models. The most important measurements in the evaluation of paediatric patients dental arches are linear measurements of tooth size, arch width, and arch length. However, in recent years, more accurate digital images of study models (digital models) have been obtained as a result of significant advances in the application of non-contact three-dimensional (3D) measuring systems [Abizadeh et al., 2012; Asquith et al., 2007; Bell et al., 2003; Bootvong et al., 2010; Dalstra and Melsen, 2009; Fleming et al., 2011; Leifert et al., 2009; Okunami et al., 2007; Park et al., 2009; Quimby et al., 2004; Redlich et al., 2008; Rosseto et al., 2009; Santoro et al., 2003; Veenema et al., 2009; Watanabe-Kanno et al., 2009; Zilberman et al., 2003]. Digital models have gained attention for their use in virtual model analysis and treatment simulation [Abizadeh et al., 2012; Asquith et al., 2007; Bell et al., 2003; Bootvong et al., 2010; Dalstra and Melsen, 2009; Fleming et al., 2011; Leifert et al., 2009; Okunami et al., 2007; Park et al., 2009; Quimby et al., 2004; Redlich et al., 2008; Rosseto et al., 2009; Santoro et al., 2003; Veenema et al., 2009; Watanabe-Kanno et al., 2009; Zilberman et al., 2003]. Furthermore, digital models have the advantages of being easy to access [Abizadeh et al., 2012; Bell et al., 2003; Leifert et al., 2009; Quimby et al., 2004; Redlich et al., 2008; Santoro et al., 2003], easy to consult [Dalstra and Melsen, 2009; Leifert et al., 2009; Quimby et al., 2004; Redlich et al., 2008; Rosseto et al., 2009; Veenema et al., 2009; Zilberman et European Journal of Paediatric Dentistry vol. 15/
2 Kaihara Y. et al. al., 2003], and have minimal storage space requirements [Abizadeh et al., 2012; Bell et al., 2003; Bootvong et al., 2010; Dalstra and Melsen, 2009; Fleming et al., 2011; Leifert et al., 2009; Quimby et al., 2004; Redlich et al., 2008; Santoro et al., 2003; Zilberman et al., 2003]. In order to ensure that these new measuring methods optimise diagnosis and treatment, it is essential that the accuracy and precision of any new type of 3D measuring system be evaluated prior to being introduced to clinical practice. To this end, it must be demonstrated that a new system estimates measurements on digital models that are comparable to measurements derived by the gold standard method, in this case the direct measurement of plaster models. Without evidence of the equivalence or superiority of the new methods to conventional ones, the quality of diagnosis and measurement-based predictions may be compromised. According to previous reports, the differences between linear measurements obtained using calipers on plaster models and those obtained from digital models were less than 0.5 mm and deemed clinically insignificant [Bell et al., 2003; Bootvong et al., 2010; Dalstra and Melsen, 2009; Leifert et al., 2009; Quimby et al., 2004; Redlich et al., 2008; Santoro et al., 2003; Zilberman et al., 2003]. However, there is currently little information about the accuracy of the 3D measuring system; a situation that must be rectified before it is introduced to clinical use. Moreover, whilst evidence validating digital models as an alternative to plaster models is accumulating, the methodological quality of the studies is variable [Fleming et al., 2011]. In order to aid paediatric dentists in deciding whether or not measurements carried out on digital models can replace those performed using the current gold standard method, an analysis of measurements made by multiple examiners using both methods on paediatric patients is called for. Such a protocol should include statistical assessment of: whether there is any systematic bias in the measurements obtained with the new method; whether there is a difference in the variability between the 2 methods; and the reliability of measurements made by different examiners. Thus, in this study, we aimed to assess the accuracy of diagnostic linear measurements of digital models obtained from the non-contact 3D measuring system in comparison with the results obtained from the gold standard method (direct measurements made on plaster models) in paediatric patients. Materials and methods The study protocol was approved by the Ethic Committee of Epidemiology, Hiroshima University (N. 329). Sample As study samples, we obtained 12 pairs of maxillary and mandibular plaster models from 12 Japanese children (6 boys and 6 girls) with deciduous dentition. The study sample included both subjects with normal occlusion and different types of malocclusion (crowding, maxillary protraction, crossbite). All the teeth in the sample had normal morphology and displayed no fracture, remarkable erosion, caries, or restorations. Measurement points The purpose of the measurements taken in this study was to enable space analysis and prediction of occlusal development. The tooth sizes, arch widths, and arch lengths were examined. Tooth size was measured as the maximum mesio-distal crown width in 2 teeth (maxillary deciduous right central incisor and mandibular deciduous right second molar). A total of 6 arch-length or arch-width measurements were made: the width of the cusp of deciduous canine on both sides and in each arch; the width of the lingual cervical line of the second deciduous molars on both sides and in each arch; and the length of the interlabial surfaces of the central deciduous incisors to the left and right distal surfaces of the second deciduous molar crown in each arch. Measurements All experiments in this study compared the direct measurements of unmarked plaster models with the measurements of digital models obtained from the same subject. Direct measurements were performed using a digital caliper (Digimatic Caliper: CD-15CPX, Mitutoyo, Kawasaki, Japan) with an accuracy of 0.01 mm. The maxillary and mandibular plaster models were individually scanned using a non-contact 3D laser scanner (RexcanDS, Solutionix, Seoul, Korea). The measurement system of the RexcanDS is based on the principle of phase-shifting optical triangulation (Fig. 1). The scanner provides non-contact high-accuracy inspection up to a quoted resolution of mm. The object is scanned with halogen light stripes, and the twin cameras receive the light reflected from the surface of the object. This procedure takes approximately 10 min and the file size of the scanned sample was approximately 30 Mb. The generated 3D model of the dental cast is exported in stereolithography format with the 3D coordinates. RapidForm 2006 software (INUS Technology, Seoul, South Korea) was used to reconstruct the scanned image into a digital model. The tooth sizes, arch width, and arch lengths were measured using a function of the RapidForm 2006 software on a computer display by clicking on the measurement points with a computer mouse. To facilitate ease and accuracy of measurements, the digital images of the model could be rotated or enlarged on the screen as required. A total of 4 examiners participated in the study and were trained in the use of both the digital caliper and the RapidForm 2006 software. In order to avoid that 1 set of measurements influenced the other set of measurements, the samples were not measured with both methods sequentially. Patients were randomly 138 European Journal of Paediatric Dentistry vol. 15/2-2014
3 dental measurements: plaster vs. three-dimensional digital models FIG. 1 A Non-contact 3D laser scanner. B, C Panels showing acquired digital images of the maxilla and the mandible. allocated to 2 of the 4 examiners and the examiner pairs alternated so that all examiners were paired with all of the other examiners over the course of the study. Each examiner used both measurement methods for each patient on 2 occasions separated by at least 2 weeks in order to avoid influence of the first measurements on the second. Thus, for a given dental measurement, there were 4 values from each of the assigned examiners for each patient for each method. In this way, a total of 96 measurements were carried out. Statistical analysis A mixed-effects linear regression model was fit to each dataset. The model contained measurement method (calipers versus digital scanning), examination (first versus second) and their interaction as fixed effects. The model contained random effects for patient, examiner and their interaction. Finally, the model contained 2 residual variance estimates, one for each method in order to allow for heteroscedasticity (i.e. unequal variances) between error variances for both methods. Using a likelihood ratio test, it was possible to test whether the 2 residual standard deviations for the methods were statistically significantly different from each other. The initial model was then reduced by means of likelihood-ratio tests to the final model, which might have removed the random effect for patient byexaminer interaction, the separate residual variances, or both. In addition, if the variance component for the examiner was too numerically small to be estimated reliably by the algorithm, both the examiner and patient by-examiner variance component were removed from the model. Using the final model, the fixed effects term for method-by-examination interaction was tested by means of the likelihood-ratio test. Likelihood-ratio tests were used to determine whether the interaction terms (patient examiner and method examination) were statistically significant at the 5% level. If not, then these terms were removed from the model. Similarly, the difference in residual variances was tested and removed from the model if it was not statistically significant. The intraclass correlation coefficient (ICC) was computed, according to the following formula: ICC = σ 2 patient/(σ 2 examiner + σ 2 patient + σ 2 patient examiner + σ 2 residual). In cases where the patient-by-examiner variance was removed from the model, or where both the examiner variance and the patient by-examiner variance were removed, the corresponding variance terms were taken as zero. When heteroscedastic residual variances were included in the final model, 2 ICC values were computed separately for each of the methods. For each method, a separate Bland Altman plot was produced by averaging measurements from both examinations for each combination of patient and examiner. From these, difference and average values between the 2 methods were computed for the plots. For equivalence, the null hypothesis was that the acceptable difference between the methods exceeds ±0.2 mm. Post hoc power analysis was performed to determine the statistic power in this study. Two Wald tests were performed, one with hypothesis that the difference was <0.2 mm and the second with hypothesis that the difference was >0.2 mm. The statistical analyses and production of graphs were performed using Stata, Release 11.2 (Stata Corp LP, Texas, USA). Results The results include the estimate of the bias (difference in millimeters between the measurements from the 2 methods) obtained from regression model fits, ICC values, and residual standard deviations (if statistically significantly different between methods). Table 1 shows fixed effects parameters of the final models. The method-by-examination interaction terms in each part were not significant and were not included in the final models. The average difference in measured values between the two methods ( fixed bias ), which are derived from the final model, was always less than 0.2 mm. The difference was statistically significant in a single case: the mandibular arch length, but the difference between methods was negligible (0.16 mm) relative to the measurement itself (arch length or width, or tooth size) which was around 30 mm. In real terms, the difference between methods although statistically significant is only about 0.5% of the magnitude of the measurement. Table 2 shows random effects parameters of final models and ICCs. Random effect of examiners was always the smallest component of variance, and frequently negligible. In 3 cases, there was statistically significant heteroscedasticity (i.e., a difference was seen between methods with regards to their residual variances), but the difference was practically insignificant in comparison to the magnitude of the random effect of the patient. Intraclass correlation coefficient was typically European Journal of Paediatric Dentistry vol. 15/
4 Kaihara Y. et al. very similar between methods even in cases of statistically significant heteroscedasticity. These were typically greater than 90% and never below the mid-80% range. Predictions from the model for the fixed effects were used to prepare Bland Altman plots for inspection of each measurement point dependencies in systematic differences between the 2 measurement methods (Fig. 2). Bland Altman plots demonstrate substantial Fixed Effects Parameters Type of tooth measurement Coefficient SE P value 95% CI Lower Upper Maxillary deciduous incisor Method Examination Constant < Mandibular deciduous molar Method Examination Constant < Maxillary intercanine width Method 0, Examination Constant < Mandibular intercanine width Method , ,15 Examination Constant < Maxillary intermolar width Method Examination Constant < Mandibular intermolar width Method < Examination Constant < Maxillary arch length Method Examination < Constant < Mandibular arch length Method Examination Constant < Method-by-examiner interaction terms in each part were not statistically significant, and were eliminated from subsequent analysis. SE = standard error; CI = confidence interval. Random-effects Parameters Type of tooth measurement Estimate SE 95% CI ICC Lower Upper Maxillary deciduous incisor SD (Examiner) SD (Patient) SD (Examiner Patient) Residual SD (Caliper) SD (3D) Mandibular deciduous molar SD (Examiner) SD (Patient) SD (Residual) Maxillary intercanine width SD (Constant) SD (Residual) Mandibular intercanine width SD (Constant) SD (Residual) Maxillary intermolar width SD (Constant) SD (Residual) Mandibular intermolar width SD (Constant) Residual SD (Caliper) SD (3D) Maxillary arch length SD (Examiner) SD (Patient) Residual SD (Caliper) SD (3D) Mandibular arch length SD (Constant) SD (Residual) SE = standard error; CI = confidence interval. tab. 1 Final models of mixedeffects linear regression models. tab. 2 Final models of mixedeffects linear regression models and intraclass correlation coefficients (ICCs) of measurement data. 140 European Journal of Paediatric Dentistry vol. 15/2-2014
5 dental measurements: plaster vs. three-dimensional digital models fig. 2 Bland Altman plots showing systematic differences between the 2 measurement methods. dependence of the difference between the 2 methods on the mean value ( proportional bias ) in many cases. Measurements made with the calipers tended to be higher than those made with the 3D scanner at the lower end of the measured range; the opposite effect was seen at the higher end of the measured range. Nevertheless, throughout the measured range, the differences between the 2 measurement methods were typically very small in comparison to the magnitude of the measurements (arch length or width, or tooth size). The post hoc test analysis revealed that the statistical power (in the case of maximum standard deviation in Table 2) was 99%. We rejected the null hypothesis to accept the alternative hypothesis that the difference between the two methods is less than ±0.2 mm. Discussion This study aimed to investigate the potential usefulness of a new non-contact 3D measuring system for the measurement of paediatric dentition models by comparison with the current gold standard method making measurements of plaster models. We found no clinically significant difference in accuracy between the direct measurement of plaster models with calipers and the measurement of 3D digital models using the computer software. The post hoc power analysis revealed that the sample size in this study was sufficient. These findings suggest that the noncontact 3D measuring system may be suitable for use in the clinical setting. Bell et al. [2003] reported that European Journal of Paediatric Dentistry vol. 15/
6 Kaihara Y. et al. the average difference between liner measurements of dental casts and 3D images was 0.27 mm, while Redlich et al. [2008] reported that the difference in space analyses between the caliper and cross-section plane measurements was very small ( mm). Santoro et al. [2003] demonstrated that tooth width and overbite measurements made on plaster and digital models showed statistically significant differences (range: mm). Quimby et al. [2004] reported similar results in all parameters except overbite and overjet. Asquith et al. [2007] reported differences in mean tooth size, intercanine width, and intermolar width ranging from to 0.19 mm. Finally, although Leifert et al. [2009] found that differences between maxillary arch length calculations were small (<0.5 mm), they concluded that the differences were clinically significant. In contrast, the difference between the means of the 2 measurement methods in this research is similar to or smaller than values reported previously, and appears to show no clinically significant difference. Although 3 measurement points demonstrated statistically significant heteroscedasticity between the residual variances of the 2 methods, the ICCs were greater than 90 and never below the mid-80% range, suggesting good agreement between the methods and achieving high reliability. With regard to differences in variability between the methods, previous reports have described increased [Dalstra and Melsen, 2009] and decreased [Quimby et al., 2004; Zilberman, et al., 2003] variability in the 3D measurements compared to those in plaster models. Despite these contrasting findings, all studies have recognised the usefulness of the 3D scanner [Quimby et al., 2004; Santoro et al., 2003; Zilberman, et al., 2003]. Bootvong et al. [2010] reported that ICCs for tooth, intercanine and intermolar width were greater than 0.70 and concluded that there was substantial to excellent agreement between assessment of tooth dimensions and arch relationships between plaster and virtual models. Our findings are in agreement with these reports, demonstrating the reliability of measurements with different examiners and the potential usefulness of the 3D scanner. Though not clinically relevant, the variation in the data sets may represent challenges in view control or landmark identification performed on a computer screen [Abizadeh et al., 2012; Asquith et al., 2007; Fleming et al., 2011; Leifert et al, 2009; Park et al., 2009; Zilberman et al., 2003]. This may be related to the inter-examiner variability that was observed in this study. Despite the potential for improvement in these aspects, our results show, nonetheless, that the analysis of dentition using a 3D scanner is comparable in terms of accuracy to the gold standard method of directly measuring a plaster models using digital caliper. In addition to the challenge of identifying certain landmarks on the computer screen, this study highlights other areas for further investigation. For example, the reliability of measurements of angle, area, and volume should be examined. It will also be important to verify the performance of the 3D scanning method at sites such as undercuts or curved surfaces, where measurements using 3D scanners are presumed to be less accurate. Clarification of these remaining issues would confirm the reliability and potential usefulness of 3D measurements of dentition models and could lead to the adoption of this simple and convenient method in paediatric clinics and academic research centres. Moreover, our results could help address issues in other similar models such as the superimposing of anatomic structures on 3D-Cone- Beam CT images or facial images, and could also help in treatment simulation/planning situations. The results of this study suggest that the accuracy of analysing the dentition of children using a 3D scanner is comparable to that of the gold standard method that employs plaster models and digital calipers. The 3D scanning system has many advantages over manual measurement methods. It is hoped that these results lead towards a more widespread adoption of this technology in paediatric dentistry. References Abizadeh N, Moles DR, O'Neill J, Noar JH. Digital versus plaster study models: how accurate and reproducible are they? J Orthod 2012;39: Asquith J, Gillgrass T, Mossey P. Three-dimensional imaging of orthodontic models: a pilot study. Eur J Orthod 2007;29: Bell A, Ayoub AF, Siebert P. Assessment of the accuracy of a three-dimensional imaging system for archiving dental study models. J Orthod 2003;30: Bootvong K, Liu Z, McGrath C, Hägg U, Wong RW, Bendeus M, Yeung S. Virtual model analysis as an alternative approach to plaster model analysis: reliability and validity. Eur J Orthod 2010;32: Dalstra M, Melsen B. From alginate impressions to digital virtual models: accuracy and reproducibility. J Orthod 2009;36: Fleming PS, Marinho V, Johal A. Orthodontic measurements on digital study models compared with plaster models: a systematic review. Orthod Craniofac Res 2011;14:1 16. Leifert MF, Leifert MM, Efstratiadis SS, Cangialosi TJ. Comparison of space analysis evaluations with digital models and plaster dental casts. Am J Orthod Dentofacial Orthop 2009;136:16.e1 e4. Okunami TR, Kusnoto B, BeGole E, Evans CA, Sadowsky C, Fadavi S. Assessing the American Board of Orthodontics objective grading system: digital vs plaster dental casts. Am J Orthod Dentofacial Orthop 2007;131: Park K, Jung DW, Kim JY. Three-dimensional space changes after premature loss of a maxillary primary first molar. Int J Paediatr Dent 2009;19: Quimby ML, Vig KW, Rashid RG, Firestone AR. The accuracy and reliability of measurements made on computer-based digital models. Angle Orthod 2004;74: Redlich M, Weinstock T, Abed Y, Schneor R, Holdstein Y, Fischer A. A new system for scanning, measuring and analyzing dental casts based on a 3D holographic sensor. Orthod Craniofac Res 2008;11: Rosseto MC, Palma FM, Ferreira RI, Pinzan A, Vellini-Ferreira F. Comparative study of dental arch width in plaster models, photocopies and digitized images. Braz Oral Res 2009;23: Santoro M, Galkin S, Teredesai M, Nicolay OF, Cangialosi TJ. Comparison of measurements made on digital and plaster models. Am J Orthod Dentofacial Orthop 2003;124: Veenema AC, Katsaros C, Boxum SC, Bronkhorst EM, Kuijpers-Jagtman AM. Index of complexity, outcome and need scored on plaster and digital models. Eur J Orthod 2009;31: Watanabe-Kanno GA, Abrão J, Miasiro Junior H, Hiroshi Sánchez-Ayala A, Lagravère MO. Reproducibility, reliability and validity of measurements obtained from Cecile3 digital models. Braz Oral Res 2009;23: Zilberman O, Huggare JA, Parikakis KA. Evaluation of the validity of tooth size and arch width measurements using conventional and three-dimensional virtual orthodontic models. Angle Orthod 2003;73: European Journal of Paediatric Dentistry vol. 15/2-2014
Virtual model analysis as an alternative approach to plaster model analysis: reliability and validity
European Journal of Orthodontics 32 (2010) 589 595 doi:10.1093/ejo/cjp159 Advance Access Publication 17 February 2010 The Author 2010. Published by Oxford University Press on behalf of the European Orthodontic
More informationTREATMENT PLANNING WITH DIGITAL ORTHODONTIC MODELS Jean-Marc Retrouvey, Liliya Nicholcheva, Nathan Light
TREATMENT PLANNING WITH DIGITAL ORTHODONTIC MODELS Jean-Marc Retrouvey, Liliya Nicholcheva, Nathan Light INTRODUCTION Digital orthodontic models are an accurate and reliable record of the patient s occlusion.
More informationAlveolar Growth in Japanese Infants: A Comparison between Now and 40 Years ago
Bull Tokyo Dent Coll (2017) 58(1): 9 18 Original Article doi:10.2209/tdcpublication.2016-0500 Alveolar Growth in Japanese Infants: A Comparison between Now and 40 Years ago Hiroki Imai 1), Tetsuhide Makiguchi
More informationEvaluation of the accuracy of digital model analysis for the American Board of Orthodontics objective grading system for dental casts
ORIGINAL ARTICLE Evaluation of the accuracy of digital model analysis for the American Board of Orthodontics objective grading system for dental casts Peter A. Costalos, a Keivan Sarraf, b Thomas J. Cangialosi,
More informationComputer technology is expanding to include
TECHNO BYTES Comparison of measurements made on digital and plaster models Margherita Santoro, DDS, MA, a Scott Galkin, DMD, b Monica Teredesai, DMD, c Olivier F. Nicolay, DDS, MS, d and Thomas J. Cangialosi,
More informationRoyal London space analysis: plaster versus digital model assessment.
Royal London space analysis: plaster versus digital model assessment. Grewal, B; Lee, RT; Zou, L; Johal, A The Author 2016. Published by Oxford University Press on behalf of the European Orthodontic Society.
More informationComparison of Measurements made on Plaster and CBCT-Scanned Models
Comparison of Measurements made on Plaster and CBCT-Scanned Models Jared T. Lee 1, Thomas J. Cangialosi 2 1 Private Practice of Orthodontics, Santa Paula, California. 2 Professor and Chair, Department
More informationMDJ Accuracy of measurements made on digital and study Vol.:7 No.:1 2010
MDJ Accuracy of measurements made on digital and study models (A comparative study) Dr. Sawsan Mohammed Murad, B.D.S., M.Sc. Prof. Dr. Ausama A. Al-Mulla, B.D.S., Dr.D.SC.(France). Abstract Background:
More informationSurface analysis of study models generated from OrthoCAD and cone-beam computed tomography imaging
ORIGINAL ARTICLE Surface analysis of study models generated from OrthoCAD and cone-beam computed tomography imaging Kurtis G. Lightheart, a Jeryl D. English, b Chung H. Kau, c Sercan Akyalcin, d Harry
More informationArch dimensional changes following orthodontic treatment with extraction of four first premolars
Received: 14 June. 2015 Accepted: 7 Dec. 2015 Arch dimensional changes following orthodontic treatment with extraction of four first premolars Abstract Asghar Ebadifar DDS, MSc 1, Mohammad Hossien Shafazand
More informationChanges of the Transverse Dental Arch Dimension, Overjet and Overbite after Rapid Maxillary Expansion (RME)
Dental Journal Changes of the Transverse Dental Arch Dimension, Overjet and Overbite after Rapid Maxillary Expansion (RME) Department of Advanced General Dentistry Faculty of Dentistry, Mahidol University.
More informationReliability and validity of intraoral and extraoral scanners
Jacob et al. Progress in Orthodontics (2015) 16:38 DOI 10.1186/s40510-015-0108-7 RESEARCH Open Access Reliability and validity of intraoral and extraoral scanners Helder B. Jacob, Graydon D. Wyatt and
More informationComparison Between Manual and Digital (2D) Measurement of Peer Assessment Rating (PAR) Score Index (Component 1-6)
Comparison Between Manual and Digital (2D) Measurement of Peer Assessment Rating (PAR) Score Index (Component 1-6) Tri Wahyudi 1, Miesje Karmiati Purwanegara 2 *, Nada Ismah 2 1. Orthodontics Residency
More informationAn Evaluation of the Use of Digital Study Models in Orthodontic Diagnosis and Treatment Planning
Original Article An Evaluation of the Use of Digital Study in Orthodontic Diagnosis and Treatment Planning Brian Rheude a ; P. Lionel Sadowsky b ; Andre Ferriera c ; Alex Jacobson d Abstract: The purpose
More informationMean Leeway space in Indian population
Original article: Mean Leeway space in Indian population 1Dr. Suchita Madhukar Tarvade (Daokar), 2 Dr. Gauri Rajkumar Agrawal, 3 Dr. Sadashiv Daokar 1Professor & PG Guide, Dept of Orthodontics, CSMSS Dental
More informationThakur H et al.applicability of various Mixed Dentition analysis among Sriganganagar School children
Original Article APPLICABILITY OF MOYER S AND TANAKA-JOHNSTON MIXED DENTITION ANALYSIS IN SCHOOL CHILDREN OF SRI GANGANAGAR DISTRICT (RAJASTHAN) A PILOT STUDY Thakur H, Jonathan PT Postgraduate student,
More informationOriginal Article. Jae-Hong Kim a,b Ki-Baek Kim a,b Woong-Chul Kim a Ji-Hwan Kim a Hae-Young Kim a,b,c
Original Article THE KOREAN JOURNAL of ORTHODONTICS pissn 2234-7518 eissn 2005-372X http://dx.doi.org/10.4041/kjod.2014.44.2.69 Accuracy and precision of polyurethane dental arch models fabricated using
More informationDetermining Tooth Size Ratio in an Iranian-Azari Population
Determining Tooth Size Ratio in an Iranian-Azari Population Abstract Aim: The aim of this investigation was to determine the tooth size ratio in an Iranian-Azari population. Method and Materials: The Bolton
More informationBiomedical Imaging for Tooth Size Measurements in a Sample of Romanian Subjects
Biomedical Imaging for Tooth Size Measurements in a Sample of Romanian Subjects EMILIA OGODESCU 1, IRINA ZETU 2, KRISZTINA MARTHA 3, ELISABETA BRATU 1, EMANUELA PETRESCU 4, ALEXANDRU OGODESCU 1 1 Department
More informationAccuracy of Ortho Insight 3D Digital Scanner in Mesial-Distal Tooth Measurements
Loma Linda University TheScholarsRepository@LLU: Digital Archive of Research, Scholarship & Creative Works Loma Linda University Electronic Theses, Dissertations & Projects 8-1-2012 Accuracy of Ortho Insight
More informationCoronal height after expansion using a Damon system
DOI: 10.1051/odfen/2017020 J Dentofacial Anom Orthod 2017;20:403 The authors Coronal height after expansion using a Damon system B. Ducroz 1, D. Brézulier 2, V. Bertaud-Gounot 3, O. Sorel 4 1 Qualified
More informationPalatal Depth and Arch Parameter in Class I Open Bite, Deep Bite and Normal Occlusion
26 Iraqi Orthod J 1(2) 2005 Palatal Depth and Arch Parameter in Class I Open Bite, Deep Bite and Normal Occlusion Ahmad A. Abdulmawjood, a Mahmood K. Ahmed, a and Ne am R. Al-Saleem a Abstract: This study
More informationEarly Mixed Dentition Period
REVIEW ARTIC CLE AODMR The Effects of a Prefabricated Functional Appliance in Early Mixed Dentition Period Toshio Iwata 1, Takashi Usui 2, Nobukazu Shirakawa 2, Toshitsugu Kawata 3 1 Doctor of Philosophy
More informationChapter 2. Material and methods
Chapter 2 Material and methods Material and methods Summary This chapter describes the subjects and methods being used in this study. Between 1986 and 1997 9 expeditions were undertaken in remote areas
More informationComparison of intraoral and extraoral scanners on the accuracy of digital model articulation
Virginia Commonwealth University VCU Scholars Compass Theses and Dissertations Graduate School 2017 Comparison of intraoral and extraoral scanners on the accuracy of digital model articulation Jason L.
More informationAre there differences between comparison methods used to evaluate the accuracy and reliability of digital models?
Are there differences between comparison methods used to evaluate the accuracy and reliability of digital models? Leonardo Tavares Camardella 1, Hero Breuning 2, Oswaldo de Vasconcellos Vilella 3 DOI:
More informationASSESSMENT OF MAXILLARY FIRST MOLAR ROTATION IN SKELETAL CLASS II, AND THEIR COMPARISON WITH CLASS I AND CLASS III SUBJECTS
ORIGINAL ARTICLE ASSESSMENT OF MAXILLARY FIRST MOLAR ROTATION IN SKELETAL CLASS II, AND THEIR COMPARISON WITH CLASS I AND CLASS III SUBJECTS ABSTRACT FARHAT AMIN, BDS, MCPS, FCPS Mesial rotation of maxillary
More informationAAO 115th Annual Session San Francisco, CA May 17 (Sunday), 1:15-2:00 pm, 2015
AAO 115th Annual Session San Francisco, CA May 17 (Sunday), 1:15-2:00 pm, 2015 Title: Clinical and iomechanical Considerations of TADs in Challenging Cases: Sagittal Correction beyond Orthodontic oundaries
More informationCephalometric Analysis
Cephalometric Analysis of Maxillary and Mandibular Growth and Dento-Alveolar Change Part III In two previous articles in the PCSO Bulletin s Faculty Files, we discussed the benefits and limitations of
More informationA Methodology for Three-Dimensional Quantification of Anterior Tooth Width
Marquette University e-publications@marquette School of Dentistry Faculty Research and Publications Dentistry, School of 5-1-2011 A Methodology for Three-Dimensional Quantification of Anterior Tooth Width
More informationA THESIS SUBMITTED TO THE FACULTY OF THE GRADUATE SCHOOL OF THE UNIVERSITY OF MINNESOTA BY
THE EFFECTIVENESS OF SURESMILE TECHNOLOGY TO ACHIEVE PREDICTED TREATMENT OUTCOME A THESIS SUBMITTED TO THE FACULTY OF THE GRADUATE SCHOOL OF THE UNIVERSITY OF MINNESOTA BY CHRISTOPHER JOHN VAUBEL IN PARTIAL
More informationResearch methodology University of Turku, Finland
Research methodology Prospective, controlled cohort study started in 1998 Treatment group: 167 children Treatment with eruption guidance appliance only Control group: 104 children No Keski-Nisula K; Keski-Nisula
More informationA Clinical and Cephalometric Study of the Influence of Mandibular Third Molars on Mandibular Anterior Teeth
10.5005/jp-journals-10021-1193 ORIGINAL ARTICLE Tara Ramprakash Kavra, Etika Kabra A Clinical and Cephalometric Study of the Influence of Mandibular Third Molars on Mandibular Anterior Teeth 1 Tara Ramprakash
More informationStable region for maxillary dental cast superimposition in adults, studied with the aid of stable miniscrews
ORIGINAL ARTICLE G Chen S Chen XY Zhang RP Jiang Y Liu FH Shi TM Xu DOI: 10.1111/j.1601-6343.2011.01510.x Stable region for maxillary dental cast superimposition in adults, studied with the aid of stable
More informationApplication of augmented reality for inferior alveolar nerve block anesthesia: A technical note
Technical Note pissn 2383-9309 eissn 2383-9317 J Dent Anesth Pain Med 2017;17(2):129-134 https://doi.org/10.17245/jdapm.2017.17.2.129 Application of augmented reality for inferior alveolar nerve block
More informationA reliable method for evaluating upper molar distalization: Superimposition of three-dimensional digital models
Original Article THE KOREAN JOURNAL of ORTHODONTICS pissn 2234-7518 eissn 2005-372X A reliable method for evaluating upper molar distalization: Superimposition of three-dimensional digital models Ruhi
More informationA validation study of reconstructed rapid prototyping models produced by two technologies
Zurich Open Repository and Archive University of Zurich Main Library Strickhofstrasse 39 CH-8057 Zurich www.zora.uzh.ch Year: 2017 A validation study of reconstructed rapid prototyping models produced
More informationRelapse of maxillary anterior crowding in Class I and Class II malocclusion treated orthodontically without extractions
O r i g i n a l A r t i c l e Relapse of maxillary anterior crowding in Class I and Class II malocclusion treated orthodontically without extractions Willian J. G. Guirro*, Karina Maria Salvatore de Freitas**,
More informationAn Anterior Tooth Size Comparison in Unilateral and Bilateral Congenitally Absent Maxillary Lateral Incisors
An Anterior Tooth Size Comparison in Unilateral and Bilateral Congenitally Absent Maxillary Lateral Incisors Abstract The purpose of this study is to compare the anterior tooth size width in patients with
More informationAttachment G. Orthodontic Criteria Index Form Comprehensive D8080. ABBREVIATIONS CRITERIA for Permanent Dentition YES NO
First Review IL HFS Dental Program Models Second Review Ortho cad Attachment G Orthodontic Criteria Index Form Comprehensive D8080 Ceph Film X-Rays Photos Narrative Patient Name: DOB: ABBREVIATIONS CRITERIA
More informationDevelopment of the Computerized Dental Cast Form Analyzing System -Three Dimensional Diagnosis of Dental Arch Form and the
Original paper Dental Materials Journal 16 (2): 180-190, 1997 Development of the Computerized Dental Cast Form Analyzing System -Three Dimensional Diagnosis of Dental Arch Form and the Investigation of
More informationEvaluation of maxillary and mandibular arch forms in an Italian adolescents sample with normocclusion
R. Ferro*, M. Pasini**, A. Fortini**, A. Arrighi**, E. Carli**, M.R. Giuca** Keywords Adolescent; Arch form; Caucasian; Dental cast; Occlusion. *Dental Unit, Regional Centre for the Study, the Prevention
More informationDoes relative maxillary arch constriction worsen with growth in patients with Cleft lip and palate? Qureshi, Nafeesa; McIntyre, Grant; Mossey, Peter
University of Dundee Does relative maxillary arch constriction worsen with growth in patients with Cleft lip and palate? Qureshi, Nafeesa; McIntyre, Grant; Mossey, Peter Published in: Journal of Cleft
More informationA comparison of crown size dimensions of the permanent teeth in a Nigerian and a British population
European Journal of Orthodontics 18 ( 1996) 623-628 11;) 1996 European Orthodontic Society A comparison of crown size dimensions of the permanent teeth in a and a population Olayinka D. Otuyemi and Joe
More informationRelationship between pretreatment case complexity and orthodontic clinical outcomes determined by the American Board of Orthodontics criteria
Original Article Relationship between pretreatment case complexity and orthodontic clinical outcomes determined by the American Board of Orthodontics criteria Hatice Akinci Cansunar a ; Tancan Uysal b
More informationIntroduction ORIGINAL ARTICLE
Clin Oral Invest (2016) 20:943 950 DOI 10.1007/s00784-015-1595-0 ORIGINAL ARTICLE Rating dental arch relationships and palatal morphology with the EUROCRAN index on three different formats of dental casts
More informationLittle s irregularity index (LII) was developed and
ORIGINAL ARTICLE Little s irregularity index: Photographic assessment vs study model assessment Naif Almasoud a and David Bearn b Manchester and Dundee, United Kingdom Introduction: The aim of this study
More informationMandibular incisor extraction: indications and long-term evaluation
European Journal of Orthodontics 18 (1996) 485-489 O 1996 European Orthodontic Society Mandibular incisor extraction: indications and long-term evaluation Jose-Antonio Canut University of Valencia, Spain
More informationCombined use of digital imaging technologies: ortho-surgical treatment
DOI: 10.1051/odfen/2018059 J Dentofacial Anom Orthod 2018;21:210 The authors Combined use of digital imaging technologies: ortho-surgical treatment L. Petitpas Private practice, 54700 Pont-à-Mousson Are
More informationCollege & Hospital, DPU Vidyapeeth Pimpri, Pune, India. *Corresponding Author:
Original Research Article DOI: 10.18231/2278-3784.2017.0001 Evaluation of changes in maxillary arch dimensions, Posterior Transverse Inter Arch Discrepancy (PTID), upper and lower incisor inclination in
More informationAn Effectiv Rapid Molar Derotation: Keles K
An Effectiv ective e and Precise Method forf Rapid Molar Derotation: Keles K TPA Ahmet Keles, DDS, DMSc 1 /Sedef Impar, DDS 2 Most of the time, Class II molar relationships occur due to the mesiopalatal
More informationKJLO. A Sequential Approach for an Asymmetric Extraction Case in. Lingual Orthodontics. Case Report INTRODUCTION DIAGNOSIS
KJLO Korean Journal of Lingual Orthodontics Case Report A Sequential Approach for an Asymmetric Extraction Case in Lingual Orthodontics Ji-Sung Jang 1, Kee-Joon Lee 2 1 Dream Orthodontic Clinic, Gimhae,
More informationSuccessful orthodontic treatment is based on extensive
ORIGINAL ARTICLE Three-dimensional dental measurements: An alternative to plaster models Hend Mohammed El-Zanaty, a Amr Ragab El-Beialy, b Amr Mohammed Abou El-Ezz, c Khaled Hazem Attia, d Ahmed Ragab
More informationVariation in arch shape and dynamics of shape change from infancy to early childhood
University of Iowa Iowa Research Online Theses and Dissertations Spring 2017 Variation in arch shape and dynamics of shape change from infancy to early childhood Gisela Lilian Borget University of Iowa
More informationApplicability of Pont's Index in Orthodontics
ORIGINAL ARTICLE Applicability of Pont's Index in Orthodontics Meena Kumari Rathi 1 and Mubassar Fida 2 ABSTRACT Objective: To investigate the applicability of Pont's index in estimating the maxillary
More informationADOLESCENT TREATMENT. Thomas J. Cangialosi. Stella S. Efstratiadis. CHAPTER 18 Pages CLASS II DIVISION 1 WHY NOW?
ADOLESCENT By Thomas J. Cangialosi and Stella S. Efstratiadis From Riolo, M. and Avery, J. Eds., Essentials for Orthodontic Practice, EFOP Press of EFOP, LLC. Ann Arbor and Grand Haven, Michigan, U.S.A.,
More informationAnterior teeth root inclination prediction derived from digital models: A comparative study of plaster study casts and CBCT images
Journal section: Orthodontics Publication Types: Research doi:10.4317/jced.55180 http://dx.doi.org/10.4317/jced.55180 Anterior teeth root inclination prediction derived from digital models: A comparative
More informationArchived SECTION 14 - SPECIAL DOCUMENTATION REQUIREMENTS
SECTION 14 - SPECIAL DOCUMENTATION REQUIREMENTS 14.1 CERTIFICATE OF MEDICAL NECESSITY...2 14.2 OPERATIVE REPORT...2 14.2.A PROCEDURES REQUIRING A REPORT...2 14.3 PRIOR AUTHORIZATION REQUEST...2 14.3.A
More informationMEDICAL ASSISTANCE BULLETIN COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF PUBLIC WELFARE
MEDICAL ASSISTANCE BULLETIN COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF PUBLIC WELFARE ISSUE DATE EFFECTIVE DATE NUMBER October 21,1996 October 28,1996 03-96-06 SUBJECT BY Information on New Procedures
More informationMaxillary Expansion and Protraction in Correction of Midface Retrusion in a Complete Unilateral Cleft Lip and Palate Patient
Case Report Maxillary Expansion and Protraction in Correction of Midface Retrusion in a Complete Unilateral Cleft Lip and Palate Patient Masayoshi Kawakami, DDS, PhD a ; Takakazu Yagi, DDS, PhD b ; Kenji
More informationInstability of tooth alignment and occlusal relationships
ORIGINAL ARTICLE Relapse revisited again Kenneth C. Dyer, a James L. Vaden, b and Edward F. Harris c Chattanooga, Cookeville, and Memphis, Tenn Introduction: Long-term changes in the dentitions of orthodontic
More informationMixed dentition analysis for black Americans
PEDIATRIC DENTISTRY/Copyright 1986 by The American Academy of Pediatric Dentistry Volume 8 Number 3 Mixed dentition analysis for black Americans Harvey H. Frankel, DMD Edward M. Benz, DMD Abstract The
More informationNonsurgical Treatment of Adult Open Bite Using Edgewise Appliance Combined with High-Pull Headgear and Class III Elastics
Case Report Nonsurgical Treatment of Adult Open Bite Using Edgewise Appliance Combined with High-Pull Headgear and Class III Elastics Isao Saito, DDS, PhD a ; Masaki Yamaki, DDS, PhD b ; Kooji Hanada,
More informationOriginal Article. International Journal of Scientific Study
Tooth Size in Crowded and Spaced Dentition among Western Uttar Pradesh Population: A Biometric Study Vishwas Bansal 1, Priyanka V. Bansal 2, Sunny Aggarwal, Manu Batra 4, Mudit Gupta 5 1 MDS, Assistant
More informationThe role of plaster models as an essential diagnostic tool in current orthodontic practice.
Original Research The role of plaster models as an essential diagnostic tool in current orthodontic practice. Shah et al * Authors: Adit Shah, Romina Kapadia**, Avinash Nawathe***, Purvesh Shah****, Dharmadev
More informationT O O T H A T L A S C O U R S E G U I D E A S S I S T A N T E D I T I O N
T O O T H A T L A S C O U R S E G U I D E A S S I S T A N T E D I T I O N The information in this guide was prepared by ehuman with contributions from: Cara Miyasaki, RDHEF, MS, Foothill College Kay Murphy,
More informationDental-arch form consists of both size and shape.
ORIGINAL ARTICLE A comparison of dental arch forms between Class II Division 1 and normal occlusion assessed by euclidean distance matrix analysis Qiong Nie a and Jiuxiang Lin b Beijing, China Introduction:
More information#60 Ortho-Tain, Inc TIMING FOR CROWDING CORRECTIONS WITH THE OCCLUS-O-GUIDE AND NITE-GUIDE APPLIANCES
#60 Ortho-Tain, Inc. 1-800-541-6612 TIMING FOR CROWDING CORRECTIONS WITH THE OCCLUS-O-GUIDE AND NITE-GUIDE APPLIANCES Although timing is not as critical for the Occlus-o-Guide appliance as it is with the
More informationAdam J. Freeman, D.D.S., 22 Imperial Avenue Westport, Connecticut
Adam J. Freeman, D.D.S., 22 Imperial Avenue Westport, Connecticut 06880 203 227-3709 Forensic Dental Report January 20, 2009 Introduction The information in this report details the examination and analysis
More informationComparison between Tanaka/Johnston and Boston University prediction approaches in a group of Iraqi pupils
ISSN: 1812 1217 Comparison between Tanaka/ and prediction approaches in a group of Iraqi pupils Khawla M Awni BDS, MSc (Assist Lect) Dept of Pedod, Orthod and Prev Dent College of Dentistry, of Mosul ABATRACT
More informationORTHODONTICS Treatment of malocclusion Assist.Lec.Kasem A.Abeas University of Babylon Faculty of Dentistry 5 th stage
Lec: Treatment of class I malocclusion Class I occlusion can be defined by Angles, classification as the mesiobuccal cusp of the upper 1 st permanent molar occlude with the developmental groove of the
More informationAn investigation of tooth size in Northern Irish people with bimaxillary dental protrusion
European Journal of Orthodontics 18 (1996) 617-621 O 1996 European Orthodontic Society An investigation of tooth size in Northern Irish people with bimaxillary dental protrusion John McCann and Donald
More informationEvaluation of the occlusion and maxillary dental arch dimensions in the mixed dentitions of Yemeni population
From the SelectedWorks of Ahmed A. Madfa Winter January 19, 2015 Evaluation of the occlusion and maxillary dental arch dimensions in the mixed dentitions of Yemeni population Ahmed A. Madfa Available at:
More informationThe Accuracy and Reproducibility of Linear Measurements Made on CBCT-derived Digital Models
Ahmad L Maroua et al ORIGINAL RESEARCH 10.5005/jp-journals-10024-1844 The Accuracy and Reproducibility of Linear Measurements Made on CBCT-derived Digital Models 1 Ahmad L Maroua, 2 Mowaffak Ajaj, 3 Mohammad
More informationAnalysis of Bolton s tooth size discrepancy for a referred UK population
Analysis of Bolton s tooth size discrepancy for a referred UK population A thesis submitted to the University of Birmingham for the degree of Master of Philosophy Submitted by Insigam Muqbil BDS MFDS RCS
More informationDr Robert Drummond. BChD, DipOdont Ortho, MChD(Ortho), FDC(SA) Ortho. Canad Inn Polo Park Winnipeg 2015
Dr Robert Drummond BChD, DipOdont Ortho, MChD(Ortho), FDC(SA) Ortho Canad Inn Polo Park Winnipeg 2015 Severely compromised FPM with poor prognosis Children often present with a developing dentition affected
More informationSPECIAL. The effects of eruption guidance and serial extraction on the developing dentition
SPECIAL The effects of eruption guidance and serial extraction on the developing dentition Robert M. Little, DDS, MSD, PhD Clinical practice is a balance of our collective experience and intuitive clinical
More informationDifferent Non Surgical Treatment Modalities for Class III Malocclusion
IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-0853, p-issn: 2279-0861. Volume 9, Issue 6 (Sep.- Oct. 2013), PP 48-52 Different Non Surgical Treatment Modalities for Class III Malocclusion
More informationUniversity of Bristol - Explore Bristol Research. Peer reviewed version. Link to published version (if available): 10.
Naish, H. J., Dunbar, C., Crouch-Baker, J., Shah, K., Wallis, C., Atack, N. E.,... Ireland, A. J. (2016). Does a true knowledge of dental crowding affect orthodontic treatment decisions? European Journal
More informationMixed-reality simulation for orthognathic surgery
Fushima and Kobayashi Maxillofacial Plastic and Reconstructive Surgery (2016) 38:13 DOI 10.1186/s40902-016-0059-z METHODOLOGY Mixed-reality simulation for orthognathic surgery Kenji Fushima 1* and Masaru
More informationAssessment of Archwidth Changes in Extraction and Non Extraction Patients. College of dental sciences, demotand, Hazaribagh, Jharkhand
ISSN- O: 2458-868X, ISSN P: 2458-8687 International Journal of Medical Science and Innovative Research (IJMSIR) IJMSIR : A Medical Publication Hub Available Online at: www.ijmsir.com Volume 2, Issue 6,
More informationThe validation of the Peer Assessment Rating index for malocclusion severity and treatment difficulty
The validation of the Peer Assessment Rating index for malocclusion severity and treatment difficulty L. DeGuzman, DMD," D. Bahiraei, BS, DMD," K. W. L. Vig, BDS, MS, FDS, D.Orth., b P. S. Vig, BDS, FDS,
More informationBiomedical Research 2017; 28 (8): ISSN X
Biomedical Research 2017; 28 (8): ISSN 0970-938X www.biomedres.info Application of computer aided design and fused deposition modeling technology in the digital manufacture of orthodontic study models.
More informationUnilateral intraoral vertical ramus osteotomy based on preoperative three-dimensional simulation surgery in a patient with facial asymmetry
CASE REPORT http://dx.doi.org/10.5125/jkaoms.2014.40.1.32 pissn 2234-7550 eissn 2234-5930 Unilateral intraoral vertical ramus osteotomy based on preoperative three-dimensional simulation surgery in a patient
More informationAging in the Craniofacial Complex
Original Article Aging in the Craniofacial Complex Longitudinal Dental Arch Changes Through the Sixth Decade Marcus M. Dager a ; James A. McNamara b ; Tiziano Baccetti c ; Lorenzo Franchi c ABSTRACT Objective:
More informationCase Report: Long-Term Outcome of Class II Division 1 Malocclusion Treated with Rapid Palatal Expansion and Cervical Traction
Case Report Case Report: Long-Term Outcome of Class II Division 1 Malocclusion Treated with Rapid Palatal Expansion and Cervical Traction Roberto M. A. Lima, DDS a ; Anna Leticia Lima, DDS b Abstract:
More informationAngle Class II, division 2 malocclusion with severe overbite and pronounced discrepancy*
O C a s e R e p o r t ngle Class II, division 2 malocclusion with severe overbite and pronounced discrepancy* Daniela Kimaid Schroeder** bstract This article reports the treatment of a young patient at
More informationISW for the treatment of adult anterior crossbite with severe crowding combined facial asymmetry case
International Research Journal of Medicine and Biomedical Sciences Vol.3 (2),pp. 15-29, November 2018 Available online at http://www.journalissues.org/irjmbs/ https://doi.org/10.15739/irjmbs.18.004 Copyright
More informationThe fact that mandibular incisor irregularity
CONTINUING EDUCATION Associations between initial, posttreatment, and postretention alignment of maxillary anterior teeth Burleigh T. Surbeck, BS, a Jon Årtun, DDS, DrOdont, b Natalie R. Hawkins, MS, c
More informationHuman Mesiodistal Tooth Width Measurements and Comparison with Dental Cast in a Bangladeshi Population
Human Mesiodistal Tooth Width Measurements and Comparison with Dental 10.5005/jp-journals-10024-1679 Cast in a Bangladeshi Population ORIGINAL RESEARCH Human Mesiodistal Tooth Width Measurements and Comparison
More informationNECESSITY FACTORS AND PREDICTORS OF DENTAL CROWDING TREATMENT
Orthodontics NECESSITY FACTORS AND PREDICTORS OF DENTAL CROWDING TREATMENT Georgeta ZEGAN 1, Cristina Gena DASCĂLU 2, Radu Bogdan MAVRU 3, Daniela ANISTOROAEI 4 1 Assoc. Prof., PhD, Dept. Surgery, Faculty
More informationAngle Class II, division 2 malocclusion with deep overbite
BBO Case Report Angle Class II, division 2 malocclusion with deep overbite Arno Locks 1 Angle Class II, division 2, malocclusion is characterized by a Class II molar relation associated with retroclined
More informationAssessment of the Accuracy of Orthodontic Digital Models
OPEN ACCESS EURASIA Journal of Mathematics Science and Technology Education ISSN: 13058223 (online) 13058215 (print) 2017 13(8):54655473 DOI: 10.12973/eurasia.2017.00844a Assessment of the Accuracy of
More information#45 Ortho-Tain, Inc PREVENTIVE ERUPTION GUIDANCE -- PREVENTIVE OCCLUSAL DEVELOPMENT
#45 Ortho-Tain, Inc. 1-800-541-6612 PREVENTIVE ERUPTION GUIDANCE -- PREVENTIVE OCCLUSAL DEVELOPMENT Analysis and Diagnosis of Occlusion: The ideal child of 5 y ears of age that probably has the best chance
More informationMeasuring Anatomical Landmark Structures to Determine the Width of Maxillary Anterior Teeth
Measuring to Determine the Width of Maxillary Anterior Teeth Annisa Ayu Larasati 1, Farisza Gita 1, Muslita Indrasari 1 * 1. Department of Prosthodontics, Faculty of Dentistry, Universitas Indonesia, Jakarta,
More informationCurrent Products and Practices Applications of 3D imaging in orthodontics: Part II
Journal of Orthodontics, Vol. 31, 2004, 154 162 FEATURES SECTION Current Products and Practices Applications of 3D imaging in orthodontics: Part II M. Y. Hajeer University of Albaath Dental School, Damascus,
More informationOrthodontic-prosthetic implant anchorage in a partially edentulous patient
Journal of Dental Sciences (2011) 6, 176e180 available at www.sciencedirect.com journal homepage: www.e-jds.com Clinical Report Orthodontic-prosthetic implant anchorage in a partially edentulous patient
More informationAlveolar Bone Remodeling and Development after Immediate Orthodontic Root Movement
Journal of Dental Health, Oral Disorders & Therapy Alveolar Bone Remodeling and Development after Immediate Orthodontic Root Abstract Introduction: Adult orthodontics is rapidly expanding primarily due
More informationComparison between the external gonial angle in panoramic radiographs and lateral cephalograms of adult patients with Class I malocclusion
425 Journal of Oral Science, Vol. 51, No. 3, 425-429, 2009 Original Comparison between the external gonial angle in panoramic radiographs and lateral cephalograms of adult patients with Class I malocclusion
More informationBolton Ratio in Different Groups of Malocclusions in Iraqi Population
Tikrit Journal for Dental Sciences 5 (2017) 19-24 Bolton Ratio in Different Groups of Malocclusio in Iraqi Population Jamal K.M (1) Key words Bolton ratio, malocclusio, oreral, tooth size ratio Abstract
More information