The Effect of Pupil Dilation on Scanning Laser Polarimetry With Variable Corneal Compensation
|
|
- Amanda Haynes
- 5 years ago
- Views:
Transcription
1 C L I N I C A L S C I E N C E The Effect of Pupil Dilation on Scanning Laser Polarimetry With Variable Corneal Compensation Amjad Horani, MD; Shahar Frenkel, MD, PhD; Eytan Z. Blumenthal, MD BACKGROUND AND OBJECTIVE: The feasibility and reproducibility of scanning laser polarimetry performed through dilated pupils rather than through non-dilated pupils was tested. PATIENTS AND METHODS: One eye each of 36 subjects (12 normal, 12 suspected glaucoma, and 12 glaucoma) was scanned using a single GDx unit with variable corneal compensator (GDx-VCC; Laser Diagnostic Technologies, Inc., San Diego, CA). Two scans prior to and two scans after dilation were performed on each study eye, resetting the cornea compensation prior to each scan. The dilated eye was viewed off-center, such that the whitish focusing patch was projected on the 9-o clock peripheral iris. After adequate anteroposterior focus, the pupil was centered and a scan was acquired. Each of 5 GDx parameters was evaluated comparing the pre-dilation and post-dilation scans. INTRODUCTION The GDx-variable corneal compensator (GDx- VCC; Laser Diagnostic Technologies, Inc., San Diego, From the Department of Ophthalmology, Hebrew University-Hadassah Medical Center, Jerusalem, Israel. Accepted for publication October 30, Dr. Blumenthal has received research support from Laser Diagnostic Technologies, Inc., San Diego, CA. Address reprint requests to Eytan Z. Blumenthal, MD, Department of Ophthalmology, Hadassah University Hospital, P. O. Box 12000, Jerusalem 91120, Israel. RESULTS: No statistically significant difference was found between pre-dilation and post-dilation measurements. There was a high pre-dilation to post-dilation correlation of 98%, 98%, 98%, 93%, and 95% for nerve fiber indicator, TSNIT average, TSNIT standard deviation, superior average, and inferior average, respectively. Less than 5% of the measurement variability was attributed to changes in pupil size (R 2 ranging from to 0.047). Stratifying the data by diagnostic groups yielded similar results. CONCLUSIONS: Pharmacologic mydriasis was not found to influence the retinal nerve fiber layer measurements acquired using the GDx-VCC. Results were comparable to scans achieved in the same eyes prior to dilation. [Ophthalmic Surg Lasers Imaging 2006;37: ] CA) is a scanning laser polarimeter, combining a confocal scanning laser ophthalmoscope with an integrated polarimeter designed to evaluate the peripapillary retinal nerve fiber layer (RNFL) thickness. Polarized light undergoes a phase shift, also called retardation, as it passes through polarizing media such as the cornea, the crystalline lens, and the RNFL. This phase shift was previously shown to correlate with the thickness of the RNFL. 1 A significant proportion of the total retardation signal from within the eye originates from the cornea. 2,3 Hence, standardizing and fully compensating for the corneal component would seem of prime importance. It can be pre- 212 OPHTHALMIC SURGERY, LASERS & IMAGING MAY/JUNE 2006 VOL 37, NO 3
2 sumed that the retardation properties of the cornea might not be homogeneous throughout, but rather change according to the thickness, curvature, and arrangement of lamella at any particular location across the cornea. The GDx-VCC incorporates a two-step approach to compensate for the retardation component derived from the polarizing properties of the anterior structures of the eye (cornea and crystalline lens). The GDx-VCC first compensates for the anterior segment polarization component by scanning the foveal area. It is believed that because the fovea is devoid of axons, and contains a symmetric arrangement of Henle fibers, any nonuniform light shift detected around the fovea must be attributed to anterior segment (cornea and lens) polarization. 4 The second step involves a compensated scan of the peripapillary retina. To correctly and reproducibly account for the corneal component of retardation, one would ideally wish to scan the eye traversing the exact same location of the cornea every time. In this way, the corneal retardation component as measured during the corneal scan would equate the retardation during the consequent peripapillary scan. Therefore, the manufacturer 5 recommends scanning only through non-dilated pupils, to reduce the variability stemming from a varying corneal component secondary to varying alignment. However, a decision to scan a patient is often made when the pupil is already dilated, such as when optic disc or RNFL layer abnormalities are first encountered. It would be advantageous to be able to scan through dilated, as well as non-dilated, pupils, and to be able to compare across the two. Hoh et al. evaluated the effect of pupillary dilation on RNFL thickness as measured by a previous version of the GDx instrument, using a fixed corneal compensation correction. 6 Although no statistically significant difference was found in the RNFL measurements in this study, up to one-fifth of dilated eyes had a change of more than 10% in RNFL thickness. Their recommendation was to perform GDx scans prior to dilation whenever possible to minimize the impact of misalignment errors. It is important to note that the newer GDx-VCC is a different device, employing different hardware and scanning algorithms, and hence the impact of scanning through a dilated pupil might differ between the two devices. In this study, we evaluated the effect of pupillary dilation on measurements obtained with the GDx-VCC device. PATIENTS AND METHODS Patients Thirty-six patients were recruited for this study at the glaucoma clinic of the Hebrew University-Hadassah Medical Center. Twelve had glaucoma, 12 had suspected glaucoma, and 12 had normal eyes. Prior to commencing the study, each subject underwent a full eye examination by an ophthalmologist trained in glaucoma, including a slit-lamp evaluation, intraocular pressure measurement, and dilated fundus examination. Inclusion criteria were a best-corrected visual acuity of 0.5 (20/40) or better and no prior surgery to the study eye. Patients with nondilatable pupils (e.g., those receiving pilocarpine or with marked pseudoexfoliation) were excluded. Eyes with glaucoma were defined as having a standard full-threshold (or SITA) visual field with a glaucoma hemifield test outside normal limits, as well as optic disc contour changes typical of glaucoma, such as excavation, rim thinning, notching, or RNFL wedge-shaped defects. Eyes with suspected glaucoma were defined as having ocular hypertension (intraocular pressure higher than 21 mm Hg) or subjects with discs that appeared suspicious but lacked a visual field defect. Normal eyes were defined as those with intraocular pressure within normal limits, normal-appearing disks, and normal visual fields. Informed consent was obtained from all participants, and the Human Subject Committee approved the methodology. One eye was randomly chosen for each subject. Each volunteer underwent a total of four scans (two prior to and two after pupil dilation) using one GDx-VCC device by a single experienced operator. The corneal compensation routine was repeated for each scan. The operator was instructed to achieve a high-quality scan, as judged by his subjective impression, as well as a machine-produced quality score of at least 8 of 10. Each good quality scan was saved and a printed copy was made. The pupil diameter was measured in room light, after which the initial two pre-dilation scans were taken. The study eye was then dilated using one drop each of tropicamide 0.5% and phenylephrine hydrochloride 10%. Once the pupil was dilated, the pupil diameter was measured again, and each subject underwent two additional post-dilation scans. Scanning a Dilated Eye The difficulty in scanning dilated eyes lies in the fact that the whitish focusing patch that is shined on the iris, EFFECT OF PUPIL DILATION ON THE GDX-VCC Horani et al. 213
3 TABLE 1 Demographic Data Characteristic Glaucoma Suspected Glaucoma Normal Total No. of subjects Mean age (y) 65.4 ± ± ± ± 12.9 Male/female ratio 6/6 6/6 4/8 17/19 just to the left of a non-dilated pupil, now falls within the margin of the dilated pupil, and hence cannot be seen on the device monitor. To overcome this obstacle, which prevents adequate anteroposterior focusing, we employed the following technique. First, the operator off-centered the eye, as seen on the device monitor, to the right (via a leftward joystick movement) such that the patch was forced to appear on the 9-o clock peripheral iris, just to the left of the pupil margin. Once the patch was focused (the endpoint being that the horizontal red line was seen bisecting the focusing patch), the operator then centered the eye (via a rightward joystick movement) and acquired an image. We found this technique to be simple to learn and employ by operators skilled in scanning non-dilated eyes. GDx Parameters From the 16 parameters appearing on the GDx printout (software version: GDx-VCC 5.1.0), we chose the 5 parameters appearing on the first printout page, which are those chosen by the manufacturer to be the most informative and that are best able to discriminate between normal and glaucomatous eyes. Temporal, superior, nasal, inferior, temporal (TSNIT) average is the average RNFL thickness within a concentric ring set at a machine-determined distance of the optic disc, such that values obtained at this ring are used by the software to calculate the different GDx parameters. Superior average is the average of the RNFL thickness values of the points within the ring along the superior 120 section. Inferior average is the average of the RNFL thickness values of the points within the ring along the inferior 120 section. TSNIT standard deviation is the standard deviation of the data points within the measured ring. Nerve fiber indicator (NFI) is a support vector machine-derived parameter indicating the likelihood that the eye is glaucomatous. Each parameter was analyzed separately, such that for each parameter for every subject, the two pre-dilation values were compared to the two post-dilation values. Statistical Analysis Mean pre-dilation and post-dilation measurements were compared using a paired t test and a Pearson correlation, and the stratification by diagnosis was tested using analysis of variance (ANOVA). The effect of the initial pupil diameter and the absolute change in pupil diameter (post-dilation minus pre-dilation) on each of the GDx parameter measurements were each tested separately using regression analysis. Data were analyzed using JMP statistical software version 5.0 (SAS Institute, Cary, NC). RESULTS Demographic data on the study subjects appear in Table 1. The mean time interval between the two sessions (± standard deviation [SD]) was 37 ± 15 minutes. The mean pupil diameter pre-dilation and post-dilation was 3.6 ± 0.8 and 7.6 ± 1.1 mm, respectively, with a mean change of 4.0 ± 0.9 mm (range: 2 to 6 mm). The mean average of each of 5 GDx parameters evaluated is listed in Table 2. Of the 5 GDx-VCC parameters evaluated, none showed a statistically significant difference when comparing the pre-dilation to the post-dilation measurements (Table 3). The two groups showed a high correlation: 98%, 98%, 98%, 93%, and 95% for the NFI, TSNIT average, TSNIT standard deviation, superior average, and inferior average, respectively. The figure demonstrates the pre-dilation to postdilation changes observed for each individual, as well as an averaged value. Stratification of the measurements by diagnosis did not show any statistically significant difference for any of the 5 parameters (Table 4). Regression analysis of the effect of the pupil size on the GDx parameters measurements revealed dependence (P values ranging from.0684 to.1906) for less than 5% 214 OPHTHALMIC SURGERY, LASERS & IMAGING MAY/JUNE 2006 VOL 37, NO 3
4 TABLE 2 Summary of the Means and Standard Deviations of the 5 GDx Parameters GDx Parameter Pre-dilation 1 Pre-dilation 2 Post-dilation 1 Post-dilation 2 NFI Mean SD TSNIT average Mean SD Superior average (µm) Mean SD Inferior average (µm) Mean SD TSNIT standard deviation Mean SD NFI = nerve fiber indicator; SD = standard deviation; TSNIT = temporal, superior, nasal, inferior, temporal. TABLE 3 Pre-dilation and Post-dilation Paired t Test With Correlations GDx Parameter t Ratio P > t Correlation NFI TSNIT average TSNIT standard deviation Superior average Inferior average NFI = nerve fiber indicator; TSNIT = temporal, superior, nasal, inferior, temporal. of the measurements variability (R 2 ranging from to 0.047). Of note, by first acquiring focus over the edge of the dilated pupil and later shifting to the center of the pupil, we were able to acquire high-quality scans with a machine-calculated quality score of 8 and above, similar to the quality scores obtained for non-dilated pupils. DISCUSSION The GDx-VCC is a noninvasive scanning laser polarimeter that allows measurement of the RNFL thickness at the posterior pole. The GDx-VCC focusing apparatus incorporates a light beam that creates a reflection seen as a round white patch on the iris, assisting in focusing the device. However, this white reflection is not seen when the pupil is fully dilated, making focusing impossible. To overcome this, the following maneuver was performed: the operator was instructed to acquire focus over the edge of the dilated pupil at the 9 o clock orientation, and then shift the fixation, by rightward movement of the joystick, across to the center of the pupil. EFFECT OF PUPIL DILATION ON THE GDX-VCC Horani et al. 215
5 TABLE 4 Pre-dilation and Post-dilation ANOVA Segregated by Diagnosis Normal Suspected Glaucoma Glaucoma GDx Parameter* F Ratio P F Ratio P F Ratio P NFI TSNIT average TSNIT standard deviation Superior average Inferior average ANOVA = analysis of variance; NFI = nerve fiber indicator; TSNIT = temporal, superior, nasal, inferior, temporal. *For each of the 5 GDx parameters, each scan pair (6 pairs in total) was compared for statistical significance across all 36 subjects. Hoh et al. 6 evaluated a previous version of the GDx confocal scanning laser polarimeter, with a fixed corneal compensator. They concluded that the GDx could not be recommended for routine use through dilated pupils due to more than 10% change in RNFL thickness after dilation in approximately one-fifth of the subjects tested. The variability found was presumed to be due to increased intertest variability and misalignment errors during image acquisition, raising the chance of scanning through the non-central cornea, resulting in retardation exceeding the range compensated for by the device. The results of our study show that pharmacologic mydriasis did not significantly alter the RNFL measurements acquired using the GDx-VCC, and that misalignment can be avoided if focus (anteroposterior movement of the joystick) is first achieved over the edge of the dilated pupil before shifting to the center of the pupil. We believe that little experience is needed to master the modification in scanning technique needed to scan dilated eyes. Our study results favor a recommendation that scanning patients with dilated pupils using the GDx- VCC produces results comparable to scans achieved in the same eyes prior to dilation. The diagnostic status of the eye (glaucoma, suspected glaucoma, or normal) did not appear to influence these results. REFERENCES Figure. The mean of the two pre-dilation (Pre) and post-dilation (Post) temporal, superior, nasal, inferior, temporal average (TSNIT Avg) measurements of each subject is presented. The thick line represents the grand mean for all subjects. 1. Weinreb RN, Dreher AW, Coleman A, et al. Histopathologic validation of Fourier-ellipsometry measurements of retinal nerve fiber layer thickness. Arch Ophthalmol. 1990;108: Greenfield DS, Knighton RW, Huang XR. Effect of corneal polarization axis on assessment of retinal nerve fiber layer thickness by scanning laser polarimetry. Am J Ophthalmol. 2000;129: Weinreb RN, Bowd C, Greenfield DS, et al. Measurement of the magnitude and axis of corneal polarization with scanning laser polarimetry. Arch Ophthalmol. 2002;120: Zhou Q, Weinreb RN. Individualized compensation of anterior segment birefringence during scanning laser polarimetry. Invest Ophthalmol Vis Sci. 2002;43: Laser Diagnostic Technologies, Inc. GDx-VCC Operation Manual, version 5.1 (pp. 2-4). San Diego, CA: Laser Diagnostic Technologies, Inc. 6. Hoh ST, Greenfield DS, Liebmann JM, et al. Effect of pupillary dilation on retinal nerve fiber layer thickness as measured by scanning laser polarimetry in eyes with and without cataract. J Glaucoma. 1999;8: OPHTHALMIC SURGERY, LASERS & IMAGING MAY/JUNE 2006 VOL 37, NO 3
Correlating Structure With Function in End-Stage Glaucoma
C L I N I C A L S C I E N C E Correlating Structure With Function in End-Stage Glaucoma Eytan Z. Blumenthal, MD; Amjad Horani, MD; Rajesh Sasikumar, MD; Chandrasekhar Garudadri, MD; Addepalli Udaykumar,
More informationSTRUCTURE & FUNCTION An Integrated Approach for the Detection and Follow-up of Glaucoma. Module 3a GDx
STRUCTURE & FUNCTION An Integrated Approach for the Detection and Follow-up of Glaucoma Module 3a GDx Educational Slide Deck Carl Zeiss Meditec, Inc. November 2005 1 Structure & Function Modules Module
More informationParafoveal Scanning Laser Polarimetry for Early Glaucoma Detection
Yamanashi Med. J. 18(1), 15~ 20, 2003 Original Article Parafoveal Scanning Laser Polarimetry for Early Glaucoma Detection Satoshi KOGURE, Yoshiki TODA, Hiroyuki IIJIMA and Shigeo TSUKAHARA Department of
More informationC a t a r a c t G l a u c o m a R e t i n a R e f r a c t i v e. The GDxVCC Early answers and ongoing assessment for glaucoma
C a t a r a c t G l a u c o m a R e t i n a R e f r a c t i v e The GDxVCC Early answers and ongoing assessment for glaucoma The quantifiable approach to quality care Only Humphrey GPA software Early insight
More informationSensitivity and specificity of new GDx parameters Colen TP, Tang NEML, Mulder PGH and Lemij HG Submitted for publication CHAPTER 7
Sensitivity and specificity of new GDx parameters Colen TP, Tang NEML, Mulder PGH and Lemij HG Submitted for publication CHAPTER 7 61 Abstract Purpose The GDx is a scanning laser polarimeter that assesses
More informationOtticaFisiopatologica
Anno quindicesimo dicembre 2010 How to assess the retinal nerve fiber layer thickness Antonio Ferreras Miguel Servet University Hospital, Zaragoza. Aragón Health Sciences Institute University of Zaragoza
More informationAbility of Scanning Laser Polarimetry (GDx) to Discriminate among Early Glaucomatous, Ocular Hypertensive and Normal Eyes in the Korean Population
Korean J Ophthalmol Vol. 18:1-8, 2004 Ability of Scanning Laser Polarimetry (GDx) to Discriminate among Early Glaucomatous, Ocular Hypertensive and Normal Eyes in the Korean Population Sun Young Lee, MD,
More informationStudy of Retinal Nerve Fiber Layer Thickness Within Normal Hemivisual Field in Primary Open-Angle Glaucoma and Normal-Tension Glaucoma
Study of Retinal Nerve Fiber Layer Thickness Within Normal Hemivisual Field in Primary Open-Angle Glaucoma and Normal-Tension Glaucoma Chiharu Matsumoto, Shiroaki Shirato, Mai Haneda, Hiroko Yamashiro
More informationEvaluation of retinal nerve fiber layer thickness parameters in myopic population using scanning laser polarimetry (GDxVCC)
Dada T et al Original article Evaluation of retinal nerve fiber layer thickness parameters in myopic population using scanning laser polarimetry (GDxVCC) Dada T1, Aggarwal A1, Bali SJ2, Sharma A1, Shah
More informationReliability analyses of the GDx nerve-fiber analyzer
VOL. 29 NO. 2 PHILIPPINE JOURNAL OF Ophthalmology APRIL ORIGINAL ARTICLE - JUNE 2004 1, 2, 3 Patricia M. Khu, MD, MS Edgardo U. Dorotheo, MD 1 Lawrence Tinio, MD 2 Cynthia P. Cordero, MS 4 1, 2, 3 Manuel
More informationCLINICAL SCIENCES. Felipe A. Medeiros, MD; Linda M. Zangwill, PhD; Christopher Bowd, PhD; Robert N. Weinreb, MD
CLINICAL SCIENCES Comparison of the GDx VCC Scanning Laser Polarimeter, HRT II Confocal Scanning Laser Ophthalmoscope, and Stratus OCT Optical Coherence Tomograph for the Detection of Glaucoma Felipe A.
More informationDetection of Glaucoma Using Scanning Laser Polarimetry with Enhanced Corneal Compensation
Detection of Glaucoma Using Scanning Laser Polarimetry with Enhanced Corneal Compensation Felipe A. Medeiros, Christopher Bowd, Linda M. Zangwill, Chirag Patel, and Robert N. Weinreb From the Hamilton
More informationTHE BASIC PATHOLOGIC CHANGE IN GLAUCOMA IS
Quantitative Assessment of Atypical Birefringence Images Using Scanning Laser Polarimetry With Variable Corneal Compensation HARMOHINA BAGGA, MD, DAVID S. GREENFIELD, MD, AND WILLIAM J. FEUER, MS PURPOSE:
More informationRelationship between the GDx VCC and Stratus OCT in Primary Open Angle Glaucoma
Relationship between the GDx VCC and Stratus OCT in Primary Open Angle Glaucoma Reza Zarei, MD 1 Mohammad Soleimani, MD 2 Sasan Moghimi, MD 3 Mohammad Yaser Kiarudi, MD 2 Mahmoud Jabbarvand, MD 1 Yadollah
More informationS Morishita, T Tanabe, S Yu, M Hangai, T Ojima, H Aikawa, N Yoshimura. Clinical science
Department of Ophthalmology and Visual Sciences, Kyoto University Graduate School of Medicine, Kyoto, Japan Correspondence to: Dr T Tanabe, Department of Ophthalmology, The Tazuke Kofukai Medical Institute,
More informationDiagnostic Accuracy of Scanning Laser Polarimetry with Enhanced versus Variable Corneal Compensation
Diagnostic Accuracy of Scanning Laser olarimetry with Enhanced versus Variable Corneal T. A. Mai, MD, N. J. Reus, MD, hd, H. G. Lemij, MD, hd urpose: To compare the diagnostic accuracy of scanning laser
More informationClinical decision making based on data from GDx: One year observations
Washington University School of Medicine Digital Commons@Becker Open Access Publications 2002 Clinical decision making based on data from GDx: One year observations James C. Bobrow Washington University
More informationAssessment of retinal ganglion cell loss is critical for the
Scanning Laser Polarimetry with Variable Corneal Compensation: Identification and Correction for Corneal Birefringence in Eyes with Macular Disease Harmohina Bagga, David S. Greenfield, and Robert W. Knighton
More informationThe evaluation of retinal nerve fiber layer in pigment dispersion syndrome and pigmentary glaucoma using scanning laser polarimetry
European Journal of Ophthalmology / Vol. 13 no. 4, 2003 / pp. 377-382 The evaluation of retinal nerve fiber layer in pigment dispersion syndrome and pigmentary glaucoma using scanning laser polarimetry
More informationRetinal Nerve Fiber Layer Measurements in Myopia Using Optical Coherence Tomography
Original Article Philippine Journal of OPHTHALMOLOGY Retinal Nerve Fiber Layer Measurements in Myopia Using Optical Coherence Tomography Dennis L. del Rosario, MD and Mario M. Yatco, MD University of Santo
More informationThe only measure of RNFL Integrity: GDxPRO
The only measure of RNFL Integrity: GDxPRO Look beyond thickness. Underlying structural organization is the key to RNFL At times, stepping onto ice is a risky proposition. Just knowing its thickness might
More informationThe only measure of RNFL Integrity : GDxPRO
The ideal glaucoma assessment tool for your practice The only measure of RNFL Integrity : GDxPRO Proven Clinical Performance Numerous studies have validated the diagnostic accuracy and performance of the
More informationStructural examina.on: Imaging
ManaMa: Glaucoma Structural examina.on: Imaging Luís Abegão Pinto, MD, PhD Department of Ophthalmology CHLC Lisbon Faculty of Medicine, Lisbon University 1 11-10- 2013 Structural changes Qualitative changes
More informationThe Role of the RNFL in the Diagnosis of Glaucoma
Chapter 1. The Role of the RNFL in the Diagnosis of Glaucoma Introduction Glaucoma is an optic neuropathy characterized by a loss of of retinal ganglion cells and their axons, the Retinal Nerve Fiber Layer
More informationScanning laser polarimetry (SLP) provides real-time, objective
The Effect of Atypical Birefringence Patterns on Glaucoma Detection Using Scanning Laser Polarimetry with Variable Corneal Compensation Christopher Bowd, Felipe A. Medeiros, Robert N. Weinreb, and Linda
More informationRetinal nerve fiber layer measured by Heidelberg retina tomograph and nerve fiber analyzer
European Journal of Ophthalmology / Vol. 15 no. 2, 2005 / pp. 246-254 Retinal nerve fiber layer measured by Heidelberg retina tomograph and nerve fiber analyzer M. IESTER 1,2, A. MERMOUD 1 1 Hopital Ophtalmique
More informationThe Relationship between Standard Automated Perimetry and GDx VCC Measurements METHODS
The Relationship between Standard Automated Perimetry and GDx VCC Measurements Nicolaas J. Reus and Hans G. Lemij PURPOSE. To investigate the relationship between retinal light sensitivity measured with
More informationReproducibility of Nerve Fiber Layer Thickness Measurements by Use of Optical Coherence Tomography
Reproducibility of Nerve Fiber Layer Thickness Measurements by Use of Optical Coherence Tomography Eytan Z. Blumenthal, MD, 1 Julia M. Williams, BS, 1 Robert N. Weinreb, MD, 1 Christopher A. Girkin, MD,
More informationMEDICAL POLICY. Proprietary Information of Excellus Health Plan, Inc. A nonprofit independent licensee of the BlueCross BlueShield Association
MEDICAL POLICY SUBJECT: OPHTHALMOLOGIC TECHNIQUES PAGE: 1 OF: 7 If the member's subscriber contract excludes coverage for a specific service it is not covered under that contract. In such cases, medical
More informationDetection of Progressive Retinal Nerve Fiber Layer Loss in Glaucoma Using Scanning Laser Polarimetry with Variable Corneal Compensation
Detection of Progressive Retinal Nerve Fiber Layer Loss in Glaucoma Using Scanning Laser Polarimetry with Variable Corneal Compensation Felipe A. Medeiros, Luciana M. Alencar, Linda M. Zangwill, Christopher
More informationScanning laser polarimetry (SLP) incorporates a confocal
Scanning Laser Polarimetry with Enhanced Corneal Compensation and Optical Coherence Tomography in Normal and Glaucomatous Eyes Mitra Sehi, 1 Stephen Ume, 1 David S. Greenfield, 1 and Advanced Imaging in
More informationRelationship Between Structure
Original Article Relationship Between Structure and Function of the Optic Nerve Head-Glaucoma versus Normal Dr Savita Bhat, Dr Anna Elias, Dr Siddharth Pawar, Dr S.J. Saikumar, Dr Alpesh Rajput, superior,
More informationDiscrimination between normal and glaucomatous eyes with visual field and scanning laser polarimetry measurements
586 Glaucoma Service, Department of Ophthalmology, University of Campinas, Campinas, Brazil R Lauande-Pimentel R A Carvalho H C Oliveira D C Gonçalves L M Silva V P Costa Glaucoma Service, Department of
More informationA comparison of HRT II and GDx imaging for glaucoma detection in a primary care eye clinic setting
(2007) 21, 1050 1055 & 2007 Nature Publishing Group All rights reserved 0950-222X/07 $30.00 www.nature.com/eye CLINICAL STUDY A comparison of HRT II and GDx imaging for glaucoma detection in a primary
More informationRetinal nerve fiber layer thickness in Indian eyes with optical coherence tomography
Original articles in Indian eyes with optical coherence tomography Malik A, Singh M, Arya SK, Sood S, Ichhpujani P Department of Ophthalmology Government Medical College and Hospital, Sector 32, Chandigarh,
More informationRelationship between GDx VCC and Stratus OCT in juvenile glaucoma
(2009) 23, 2182 2186 & 2009 Macmillan Publishers Limited All rights reserved 09-222X/09 $32.00 www.nature.com/eye CLINICAL STUDY Relationship between GDx VCC and Stratus OCT in juvenile glaucoma R Zareii,
More informationSeiji T. Takagi, Yoshiyuki Kita, Asuka Takeyama, and Goji Tomita. 1. Introduction. 2. Subjects and Methods
Ophthalmology Volume 2011, Article ID 914250, 5 pages doi:10.1155/2011/914250 Clinical Study Macular Retinal Ganglion Cell Complex Thickness and Its Relationship to the Optic Nerve Head Topography in Glaucomatous
More informationRelationship between Scanning Laser Polarimetry with Enhanced Corneal Compensation and with Variable Corneal Compensation
Korean Journal of Ophthalmology 22(1):18-25, 2008 DOI : 10.3341/kjo.2008.22.1.18 Relationship between Scanning Laser Polarimetry with Enhanced Corneal Compensation and with Variable Corneal Compensation
More informationScanning Laser Polarimetry and Optical Coherence Tomography for Detection of Retinal Nerve Fiber Layer Defects
접수번호 : 2008-105 Korean Journal of Ophthalmology 2009;23:169-175 ISSN : 1011-8942 DOI : 10.3341/kjo.2009.23.3.169 Scanning Laser Polarimetry and Optical Coherence Tomography for Detection of Retinal Nerve
More informationCorporate Medical Policy
Corporate Medical Policy Glaucoma, Evaluation by Ophthalmologic Techniques File Name: Origination: Last CAP Review: Next CAP Review: Last Review: glaucoma_evaluation_by_ophthalmologic_techniques 3/2001
More informationScanning Laser Polarimetry in Patients with Acute Attack of Primary Angle Closure
Scanning Laser Polarimetry in Patients with Acute Attack of Primary Angle Closure Jimmy S. M. Lai*, Clement C. Y. Tham, Jonathan C. H. Chan*, Nelson K. F. Yip, Wilson W. T. Tang, Patrick S. H. Li*, Jane
More informationTranslating data and measurements from stratus to cirrus OCT in glaucoma patients and healthy subjects
Romanian Journal of Ophthalmology, Volume 60, Issue 3, July-September 2016. pp:158-164 GENERAL ARTICLE Translating data and measurements from stratus to cirrus OCT in glaucoma patients and healthy subjects
More informationRETINAL NERVE FIBER LAYER
CLINICAL SCIENCES The Effect of Scan Diameter on Retinal Nerve Fiber Layer Thickness Measurement Using Stratus Optic Coherence Tomography Giacomo Savini, MD; Piero Barboni, MD; Michele Carbonelli, MD;
More informationGlaucoma: Diagnostic Modalities
Glaucoma: Diagnostic Modalities - Dr. Barun Kumar Nayak, Dr. Sarika Ramugade Glaucoma is a leading cause of blindness in the world, especially in older people. Early detection and treatment by ophthalmologist
More informationMEDICAL POLICY. Proprietary Information of YourCare Healthcare
MEDICAL POLICY PAGE: 1 OF: 7 If the member's subscriber contract excludes coverage for a specific service it is not covered under that contract. In such cases, medical policy criteria are not applied.
More informationEye Movements, Strabismus, Amblyopia, and Neuro-Ophthalmology
Eye Movements, Strabismus, Amblyopia, and Neuro-Ophthaology Scanning Laser Polarimetry, but Not Optical Coherence Tomography Predicts Permanent Visual Field Loss in Acute Nonarteritic Anterior Ischemic
More informationPosition of retinal blood vessels correlates with retinal nerve fibre layer thickness profiles as measured with GDx VCC and ECC
Department of Ophthalmology, Medical University of Vienna, Austria Correspondence to Clemens Vass, Department of Ophthalmology and Optometry, Medical University of Vienna, General Hospital, Währinger Gürtel
More informationFourier Analysis of Scanning Laser Polarimetry Measurements with Variable Corneal Compensation in Glaucoma
Fourier Analysis of Scanning Laser Polarimetry Measurements with Variable Corneal Compensation in Glaucoma Felipe A. Medeiros, Linda M. Zangwill, Christopher Bowd, Antje S. Bernd, and Robert N. Weinreb
More informationRetinal Nerve Fiber Layer Measurement Variability with Spectral Domain Optical Coherence Tomography
pissn: 1011-8942 eissn: 2092-9382 Korean J Ophthalmol 2012;26(1):32-38 http://dx.doi.org/10.3341/kjo.2012.26.1.32 Retinal Nerve Fiber Layer Measurement Variability with Spectral Domain Optical Coherence
More informationCirrus TM HD-OCT. Details defi ne your decisions
Cirrus TM HD-OCT Details defi ne your decisions 2 With high-defi nition OCT Carl Zeiss Meditec takes you beyond standard spectral domain Built on 10 years experience at the vanguard of innovation, Carl
More informationKey words: Glaucoma, Imaging, Ophthalmoscopy, Optic neuropathy, Topography
194 Review Article Evaluating the Optic Nerve and Retinal Nerve Fibre Layer: The Roles of Heidelberg Retina Tomography, Scanning Laser Polarimetry and Optical Coherence Tomography Sek-Tien Hoh, 1 MBBS,
More informationLARGE DISCS WITH LARGE CUPS A DIAGNOSTIC CHALLENGE IN AFRICAN PATIENTS. Darshana Soma
LARGE DISCS WITH LARGE CUPS A DIAGNOSTIC CHALLENGE IN AFRICAN PATIENTS Darshana Soma A research report submitted to the Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, in partial
More informationTo assess the glaucoma diagnostic ability of Fourier Domain Optical Coherence Tomography
American Journal of Engineering Research (AJER) e-issn : 2320-0847 p-issn : 2320-0936 Volume-02, Issue-11, pp-104-110 www.ajer.org Research Paper Open Access To assess the glaucoma diagnostic ability of
More informationSTANDARD AUTOMATED PERIMETRY IS A GENERALLY
Comparison of Long-term Variability for Standard and Short-wavelength Automated Perimetry in Stable Glaucoma Patients EYTAN Z. BLUMENTHAL, MD, PAMELA A. SAMPLE, PHD, LINDA ZANGWILL, PHD, ALEXANDER C. LEE,
More informationAlthough measurements of the optic disc and retinal nerve
Longitudinal Variability of Optic Disc and Retinal Nerve Fiber Layer Measurements Christopher Kai-shun Leung, 1,2 Carol Yim-lui Cheung, 1 Dusheng Lin, 1,3 Chi Pui Pang, 1 Dennis S. C. Lam, 1 and Robert
More informationCollaboration in the care of glaucoma patients and glaucoma suspects. Barry Emara MD FRCS(C) Nico Ristorante November 29, 2012
Collaboration in the care of glaucoma patients and glaucoma suspects Barry Emara MD FRCS(C) Nico Ristorante November 29, 2012 Goals of Collaboration Patient-centred and evidence based approach Timely access
More informationGanglion cell complex scan in the early prediction of glaucoma
Original article in the early prediction of glaucoma Ganekal S Nayana Super Specialty Eye Hospital and Research Center, Davangere, Karnataka, India Abstract Objective: To compare the macular ganglion cell
More information53 year old woman attends your practice for routine exam. She has no past medical history or family history of note.
Case 1 Normal Tension Glaucoma 53 year old woman attends your practice for routine exam. She has no past medical history or family history of note. Table 1. Right Eye Left Eye Visual acuity 6/6 6/6 Ishihara
More informationInternational Journal of Scientific & Engineering Research, Volume 4, Issue 12, December ISSN
International Journal of Scientific & Engineering Research, Volume 4, Issue 12, December-2013 108 Name of Chief and Corresponding Author : Dr Chandrima Paul TITLE : Comparison of glaucoma diagnostic ability
More information* Şükrü Bayraktar, MD, Zerrin Bayraktar, MD, and Ömer Faruk Yilmaz, MD
Journal of Glaucoma 10:163 169 2001 Lippincott Williams & Wilkins, Inc. Influence of Scan Radius Correction for Ocular Magnification and Relationship Between Scan Radius With Retinal Nerve Fiber Layer
More informationMacular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma
Med. J. Cairo Univ., Vol. 83, No. 2, September: 67-72, 2015 www.medicaljournalofcairouniversity.net Macular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma
More informationA vailability of the scanning laser polarimeter now permits
70 CLINICAL SCIENCE Specificity and sensitivity of glaucoma detection in the Japanese population using scanning laser polarimetry Shigeo Funaki, Motohiro Shirakashi, Kiyoshi Yaoeda, Haruki Abe, Shiho Kunimatsu,
More informationAvailable online at Pelagia Research Library. Advances in Applied Science Research, 2013, 4(6):
Available online at www.pelagiaresearchlibrary.com Advances in Applied Science Research, 2013, 4(6):201-206 ISSN: 0976-8610 CODEN (USA): AASRFC Comparison of glaucoma diagnostic ability of retinal nerve
More informationDiagnostic Accuracy of OCT with a Normative Database to Detect Diffuse Retinal Nerve Fiber Layer Atrophy: Diffuse Atrophy Imaging Study METHODS
Glaucoma Diagnostic Accuracy of OCT with a Normative Database to Detect Diffuse Retinal Nerve Fiber Layer Atrophy: Diffuse Atrophy Imaging Study Jin Wook Jeoung, 1,2 Seok Hwan Kim, 1,3 Ki Ho Park, 1,2
More informationComparison of Optic Disc Topography Measured by Retinal Thickness Analyzer with Measurement by Heidelberg Retina Tomograph II
Comparison of Optic Disc Topography Measured by Retinal Analyzer with Measurement by Heidelberg Retina Tomograph II Noriko Itai*, Masaki Tanito*, and Etsuo Chihara* *Senshokai Eye Institute, Uji, Kyoto,
More informationTest-retest variability in visual field testing using frequency doubling technology
European Journal of Ophthalmology / Vol. 17 no. 2, 2007 / pp. 203-207 Test-retest variability in visual field testing using frequency doubling technology A. HORANI, S. FRENKEL, E.Z. BLUMENTHAL Department
More informationComparative evaluation of time domain and spectral domain optical coherence tomography in retinal nerve fiber layer thickness measurements
Original article Comparative evaluation of time domain and spectral domain optical coherence tomography in retinal nerve fiber layer thickness measurements Dewang Angmo, 1 Shibal Bhartiya, 1 Sanjay K Mishra,
More informationNERVE FIBER LAYER THICKNESS IN NORMALS AND GLAUCOMA PATIENTS
Nerve fiber layer thickness in normals and glaucoma patients 403 NERVE FIBER LAYER THICKNESS IN NORMALS AND GLAUCOMA PATIENTS HIROTAKA SUZUMURA, KAYOKO HARASAWA, AKIKO KOBAYASHI and NARIYOSHI ENDO Department
More informationGLAUCOMA SUMMARY BENCHMARKS FOR PREFERRED PRACTICE PATTERN GUIDELINES
SUMMARY BENCHMARKS FOR PREFERRED PRACTICE PATTERN GUIDELINES Introduction These are summary benchmarks for the Academy s Preferred Practice Pattern (PPP) guidelines. The Preferred Practice Pattern series
More informationLinking structure and function in glaucoma
CET CONTINUING Sponsored by 1 CET POINT Linking structure and function in glaucoma 50 Dr Samantha McGinnigle PhD, BSc (Hons), MCOptom, AHEA This article will give an overview of the latest imaging technology
More informationComparative study of new imaging technologies for the diagnosis of glaucoma: Protocol Approved by the Ethics Committee
Comparative study of new imaging technologies for the diagnosis of glaucoma: Protocol Approved by the Ethics Committee HTA 09/22/111. Applicants: Augusto Azuara-Blanco (CI), Jennifer Burr,, Rodolfo Hernández,
More informationCirrus TM HD-OCT. Details define your decisions
Cirrus TM HD-OCT Details define your decisions 2 With high-definition OCT Carl Zeiss Meditec takes you beyond standard spectral domain Built on 10 years experience at the vanguard of innovation, Carl Zeiss
More informationMoving forward with a different perspective
Moving forward with a different perspective The Leader In Vision Diagnostics Offers A New Perspective Marco has served the eyecare community by offering exceptional lane products and automated high tech
More informationEarly Detection Of Glaucoma Clinical Clues. Points To Live By. Glaucoma Risk Factors 10/3/2014
Early Detection Of Glaucoma Clinical Clues Eric E. Schmidt, O.D. Omni Eye Specialists Wilmington, NC schmidtyvision@msn.com Points To Live By 25% of G pxs NEVER have IOP >21mm 50% of G pxs have trough
More informationGlaucoma detection using the GDx nerve fiber analyzer and the retinal thickness analyzer
European Journal of Ophthalmology / Vol. 16 no. 0, 2006 / pp. 21-000 Glaucoma detection using the GDx nerve fiber analyzer and the retinal thickness analyzer E.M. HOFFMANN 1, 2, C. BOWD 2, N. KLEIN 1,
More informationIn some patients with glaucoma, standard (achromatic) automated
Detecting Early Glaucoma by Assessment of Retinal Nerve Fiber Layer Thickness and Visual Function Christopher Bowd, 1 Linda M. Zangwill, 1 Charles C. Berry, 2 Eytan Z. Blumenthal, 1 Cristiana Vasile, 1
More informationAssessing the Relationship between Central Corneal Thickness and Retinal Nerve Fiber Layer Thickness in Healthy Subjects
1 1 1 1 1 1 Assessing the Relationship between Central Corneal Thickness and Retinal Nerve Fiber Layer Thickness in Healthy Subjects Authors: Tarkan Mumcuoglu, 1* Kelly A Townsend, 1* Gadi Wollstein, 1
More informationAnalysis of GDx-VCC Polarimetry Data by Wavelet-Fourier Analysis across Glaucoma Stages
Analysis of GDx-VCC Polarimetry Data by Wavelet-Fourier Analysis across Glaucoma Stages Edward A. Essock, 1,2 Yufeng Zheng, 1 and Pinakin Gunvant 1 PURPOSE. The purpose of this study was to apply shape-based
More informationThickness Changes in the Fovea and Peripapillary Retinal Nerve Fiber Layer Depend on the Degree of Myopia
Thickness Changes in the Fovea and Peripapillary Retinal Nerve Fiber Layer Depend on the Degree of Myopia Sung-Won Choi, MD, Seok-Joon Lee, MD Department of Ophthalmology, Wonju Christian Hospital. Yonsei
More informationG laucoma is a progressive optic neuropathy in which
1135 EXTENDED REPORT The correlation between optic nerve head topographic measurements, peripapillary nerve fibre layer thickness, and visual field indices in glaucoma Y-W Lan, D B Henson, A J Kwartz...
More informationInvestigation of the relationship between central corneal thickness and retinal nerve fiber layer thickness in ocular hypertension
Acta Medica Anatolia Volume 2 Issue 1 2014 Investigation of the relationship between central corneal thickness and retinal nerve fiber layer thickness in ocular hypertension Remzi Mısır 1, Sinan Sarıcaoğlu
More informationA Review Of Risk Factors. Early Detection Of Glaucoma Clinical Clues. A risk factor analysis is critical. Points To Live By
A Review Of Risk Factors Early Detection Of Glaucoma Clinical Clues Eric E. Schmidt, O.D. Omni Eye Specialists Wilmington, NC schmidtyvision@msn.com FINDACAR Family history IOP Nearsightedness Diabetes/Vascular
More informationAssessment of the Retinal Nerve Fiber Layer in Clinical Trials of Glaucoma Neuroprotection
SURVEY OF OPHTHALMOLOGY VOLUME 45 SUPPLEMENT 3 MAY 2001 Assessment of the Retinal Nerve Fiber Layer in Clinical Trials of Glaucoma Neuroprotection Eytan Z. Blumenthal, MD, and Robert N. Weinreb, MD Glaucoma
More informationNoel de Jesus Atienza, MD, MSc and Joseph Anthony Tumbocon, MD
Original Article Philippine Journal of OPHTHALMOLOGY Diagnostic Accuracy of the Optical Coherence Tomography in Assessing Glaucoma Among Filipinos. Part 1: Categorical Outcomes Based on a Normative Database
More informationTargeting Intraocular Pressure in Glaucoma: a Teaching Case Report 1
Targeting Intraocular Pressure in Glaucoma: a Teaching Case Report 1 By: Andrew Kemp, OD, Marcus Gonzales, OD, FAAO, Joe DeLoach, OD, FAAO, and Zanna Kruoch, OD FAAO Background Glaucoma is a range of conditions
More informationMethod for comparing visual field defects to local RNFL and RGC damage seen on frequency domain OCT in patients with glaucoma.
Method for comparing visual field defects to local RNFL and RGC damage seen on frequency domain OCT in patients with glaucoma. Donald C. Hood 1,2,* and Ali S. Raza 1 1 Department of Psychology, Columbia
More informationADVANCED DIAGNOSTIC TECHNIQUES
DIVISION OF VISION SCIENCES SESSION: 2008/2009 DIET: 1ST ADVANCED DIAGNOSTIC TECHNIQUES VISP216 LEVEL:2 MODULE LEADER: DR GUNTER LOFFLER B.Sc/B.Sc. (HONS) OPTOMETRY MAY 2009 DURATION: 2 HOURS CANDIDATES
More informationOptic Disc Evaluation: Is the Optic Disc Glaucomatous and Has it Progressed?
Optic Disc Evaluation: Is the Optic Disc Glaucomatous and Has it Progressed? Jody Piltz-Seymour, M.D. Clinical Professor Perelman School of Medicine University of Pennsylvania Wills Glaucoma Service Valley
More informationAdvances in OCT Murray Fingeret, OD
Disclosures Advances in OCT Murray Fingeret, OD Consultant Alcon, Allergan, Bausch & Lomb, Carl Zeiss Meditec, Diopsys, Heidelberg Engineering, Reichert, Topcon Currently Approved OCT Devices OCT Devices
More informationPRIMUS 200 from ZEISS The essential OCT
PRIMUS 200 from ZEISS The essential OCT Seeing beyond the surface. ZEISS PRIMUS 200 // INNOVATION MADE BY ZEISS Clear Visualization. Advanced Technology. Reliability. Essential elements of your first OCT.
More informationChanges in Peripapillary Retinal Nerve Fiber Layer Thickness after Pattern Scanning Laser Photocoagulation in Patients with Diabetic Retinopathy
pissn: 1011-8942 eissn: 2092-9382 Korean J Ophthalmol 2014;28(3):220-225 http://dx.doi.org/10.3341/kjo.2014.28.3.220 Original Article Changes in Peripapillary Retinal Nerve Fiber Layer Thickness after
More informationRelation of optic disc topography and age to thickness of retinal nerve fibre layer as measured using scanning laser polarimetry, in normal subjects
Br J Ophthalmol 2000;84:473 478 473 Department of Ophthalmology, Celal Bayar University School of Medicine, Manisa, Turkey A B Toprak Department of Ophthalmology, Beyoglu Hospital, Taksim, Istanbul, Turkey
More informationComparison of Retinal Nerve Fiber Layer Thickness between Stratus and Spectralis OCT
pissn: 1011-8942 eissn: 2092-9382 Korean J Ophthalmol 2011;25(3):166-173 DOI: 10.3341/kjo.2011.25.3.166 Original Article Comparison of Retinal Nerve Fiber Layer Thickness between Stratus and Spectralis
More informationGlaucoma Evaluation. OCT Pearls for Glaucoma. OCT: Retinal Nerve Fiber Layer. Financial Disclosures. OCT: Macula. Case Example
OCT Pearls for Glaucoma using OCT of the macula for glaucoma Glaucoma Evaluation Right eye Visual Acuity 20/25 20/25 IOP 13 13 Central corneal 530 530 thickness Anterior exam Normal with PCIOL Normal with
More informationFrom the Massachusetts Eye and Ear Infirmary, Glaucoma Service, Harvard Medical School, Department of Ophthalmology, Boston, Massachusetts.
SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY IN GLAUCOMA: QUALITATIVE AND QUANTITATIVE ANALYSIS OF THE OPTIC NERVE HEAD AND RETINAL NERVE FIBER LAYER (AN AOS THESIS) BY Teresa C. Chen MD ABSTRACT Purpose:
More informationORIGINAL CONTRIBUTION. Retinal Imaging by Laser Polarimetry and Optical Coherence Tomography Evidence of Axonal Degeneration in Multiple Sclerosis
ORIGINAL CONTRIBUTION Retinal Imaging by Laser Polarimetry and Optical Coherence Tomography Evidence of Axonal Degeneration in Multiple Sclerosis Maulik S. Zaveri, MS; Amy Conger, COA; Amber Salter, MS;
More informationReports. Macular Thickness as a Potential Biomarker of Mild Alzheimer s Disease
Reports Macular Thickness as a Potential Biomarker of Mild Alzheimer s Disease Although several postmortem findings in the retina of patients with Alzheimer s disease (AD) are available, 1 new biomarkers
More informationCorrelation Between Frequency Doubling Technology Perimetry and Scanning Laser Polarimetry in Glaucoma Suspects and Glaucomatous Eyes
Korean J Ophthalmol Vol. 18:89-99, 2004 Correlation Between Frequency Doubling Technology Perimetry and Scanning Laser Polarimetry in Glaucoma Suspects and Glaucomatous Eyes Su Hyun Kim, MD, Hunei Hong,
More informationRETINAL SCANNING LASER POLARIMETRY AND
RETINAL SCANNING LASER POLARIMETRY AND METHODS TO COMPENSATE FOR CORNEAL BIREFRINGENCE ZHOU Q. 1,2 ABSTRACT Scanning laser polarimetry (SLP) was developed to provide objective assessment of the retinal
More informationImaging of the optic disc and retinal nerve fiber layer: the effects of age, optic disc area, refractive error, and gender
Bowd et al. Vol. 19, No. 1/January 2002/J. Opt. Soc. Am. A 197 Imaging of the optic disc and retinal nerve fiber layer: the effects of age, optic disc area, refractive error, and gender Christopher Bowd,
More information