RESEARCH ABSTRACT INTRODUCTION

Size: px
Start display at page:

Download "RESEARCH ABSTRACT INTRODUCTION"

Transcription

1 Definition of ambulatory blood targets for diagnosis and treatment of hypertension in relation to clinic blood : prospective cohort study Geoffrey A Head, NHMRC principal research fellow and professor of pharmacology, 1 Anastasia S Mihailidou, senior hospital scientist and clinical senior lecturer, 2 Karen A Duggan, associate professor, 3 Lawrence J Beilin, Winthrop professor of medicine, 4 Narelle Berry, postdoctoral research fellow, 5 Mark A Brown, professor of renal medicine, 6 Alex J Bune, associate professor, 7 Diane Cowley, clinical nurse consultant, 8 John P Chalmers, senior director, the George Institute and emeritus professor of medicine, 9 Peter R C Howe, research professor, 5 Jonathan Hodgson, professor, 4 John Ludbrook, professorial fellow, 10 Arduino A Mangoni, associate professor of clinical pharmacology, 11 Barry P McGrath, professor of vascular medicine, 12 Mark R Nelson, professorial fellow, 13 James E Sharman, senior research fellow, 13,14 Michael Stowasser, codirector, 8 for the Ambulatory Blood Pressure Working Group of the High Blood Pressure Research Council of Australia 1 Baker IDI Heart and Diabetes Institute, Melbourne, Victoria 8008, Australia 2 Royal North Shore Hospital and University of Sydney, Sydney, Australia 3 Sydney South West Area Health Service, Sydney 4 School of Medicine and Pharmacology, University of Western Australia, Royal Perth Hospital, Perth, Australia 5 Nutritional Physiology Research Centre, University of South Australia, Adelaide, Australia 6 University of New South Wales, St George Hospital, Sydney 7 University of Sydney, Royal Prince Alfred Hospital, Camperdown, Australia 8 Hypertension Unit, Princess Alexandra Hospital, University of Queensland School of Medicine, Brisbane, Australia 9 George Institute, University of Sydney, Sydney 10 University of Melbourne, Parkville, Australia 11 Department of Clinical Pharmacology, Flinders University, Adelaide 12 Monash University, Centre for Vascular Health, Southern Health, Dandenong, Australia 13 Menzies Research Institute, Hobart, Australia 14 Endocrine Hypertension Research Centre, School of Medicine, University of Queensland, Brisbane, Australia Correspondence to: G A Head geoff.head@baker.edu.au Cite this as: BMJ 2010;340:c1104 ABSTRACT Background Twenty-four hour ambulatory blood thresholds have been defined for the diagnosis of mild hypertension but not for its treatment or for other blood thresholds used in the diagnosis of moderate to severe hypertension. We aimed to derive age and sex related ambulatory blood equivalents to clinic blood thresholds for diagnosis and treatment of hypertension. Methods We collated 24 hour ambulatory blood data, recorded with validated devices, from 11 centres across six Australian states (n=8575). We used least product regression to assess the relation between these measurements and clinic blood measured by trained staff and in a smaller cohort by doctors (n=1693). Results Mean age of participants was 56 years (SD 15) with mean body mass index 28.9 (5.5) and mean clinic systolic/diastolic blood 142/82 mm Hg (19/12); 4626 (54%) were women. Average clinic measurements by trained staff were 6/3 mm Hg higher than daytime ambulatory blood and 10/5 mm Hg higher than 24 hour blood, but 9/7 mm Hg lower than clinic values measured by doctors. Daytime ambulatory equivalents derived from trained staff clinic measurements were 4/3 mm Hg less than the 140/90 mm Hg clinic threshold (lower limit of grade 1 hypertension), 2/2 mm Hg less than the 130/80 mm Hg threshold (target upper limit for patients with associated conditions), and 1/1 mm Hg less than the 125/75 mm Hg threshold. Equivalents were 1/2 mm Hg lower for women and 3/ 1 mm Hg lower in older people compared with the combined group. Conclusions Our study provides daytime ambulatory blood thresholds that are slightly lower than equivalent clinic values. Clinic blood measurements taken by doctors were considerably higher than those taken by trained staff and therefore gave inappropriate estimates of ambulatory thresholds. These results provide a framework for the diagnosis and management of hypertension using ambulatory blood values. INTRODUCTION Hypertension is a major risk factor for cardiovascular morbidity and mortality. Blood measurements taken in the clinic or office provide limited information about the true blood load, and measurements taken elsewhere are often needed to best guide the diagnosis and treatment of hypertension. Ambulatory blood monitoring is useful in the clinical evaluation of patients with hypertension, especially since it can predict long term end organ damage such as left ventricular hypertrophy. 1-3 Furthermore, ambulatory measurement is the only commonly used practical method to determine the absence of nocturnal blood dipping, 4 which is associated with a raised incidence of stroke, 5 target organ damage, 6 and other cardiovascular events. 7 Consensus guidelines for the treatment of hypertension have become increasingly sophisticated and advocate specific goals for individuals at high risk of cardiovascular adverse events, such as those with diabetes, coronary artery disease, or chronic kidney disease. 8 Most guidelines are based on clinic or office evaluations of blood and similar guidelines are needed for ambulatory blood measurements. 9 Guidelines for ambulatory blood differ in the thresholds defined as normal for triggering management decisions. Recently suggested upper limits for systolic/diastolic blood are 135/85 for daytime, 120/75 for night time, and 130/80 for 24 hour measurements These values have been derived BMJ ONLINE FIRST bmj.com page 1 of 8

2 doi: /bmj.c1104 page 2 of 8 from several sources including population studies, large multicentre studies with participants considered normotensive, 12 and meta-analyses that correlate ambulatory blood with cardiovascular outcomes. These approaches do not necessarily relate to measurements in the clinic on which the guidelines for treatment are based and which are often taken by non-physician health professionals. An alternative approach has been to determine the relation between office and ambulatory blood measurements by linear regression and use the derived equation to predict the equivalent for the clinic blood of 140/90 mm Hg, which represents mild hypertension. The PAMELA study was a landmark study in this regard, showing a high degree of correlation (r=0.66) between physician measured clinic blood and ambulatory blood measurements from 1438 participants aged 25 to 65 years from Monza, Italy. 15 They predicted that a clinic blood measure of 140/90 mm Hg was equivalent to a 24 hour ambulatory blood value of 125/80 mmhg and a daytime value of 130/85 mm Hg in men and slightly less in women. A strength of the PAMELA study was that it was conducted in a random sample of people from the general population. It provided a method by which ambulatory blood could be related to outcome data that had been defined in terms of clinic blood. Subsequent studies from Scandinavian and South American 18 populations used similar approaches. However, no published studies have defined the ambulatory blood levels that are equivalent to the various treatment targets used for hypertensive people with comorbidities, or to the blood levels used to classify severity of hypertension. In this multicentre study, we used clinic and ambulatory blood measurements to obtain reference ambulatory blood thresholds for the diagnosis and management of hypertension that accounted for age and sex. We also compared clinic measurements taken by non-medically qualified health professionals with those taken by doctors, to assess whether a white coat effect might have influenced the findings of previous studies that were based on doctor s measurements alone. METHODS We recruited 8529 participants from 11 hypertension clinics, representing all six Australian states, to compare measurements of clinic blood and 24 hour ambulatory blood (see supplementary table S3 for detailed characteristics of participants by state). Most participants had been referred by doctors to the ambulatory blood service for evaluation of their 24 hour blood. The people recruited were therefore typical of those referred for ambulatory assessment, which generally included individuals with suspected white coat hypertension, resistant or difficult to treat hypertension, or hypertension associated with renal disease, and individuals whose referring physician was unsure whether antihypertensive medication was required. Some centres recruited by advertising from the general population and contributed a substantial proportion of healthy participants. Age, sex, ethnicity, body mass index, and hypertensive treatment status were also recorded if available. Cardiovascular measurements Ambulatory blood was recorded for at least a 24 hour period during a typical day using validated devices (SpaceLabs or 90217, 19 SpaceLabs Medical, Redmond, WA, United States; A&D model TM2430, 19 A&D Medical, Kensington, VIC, or Seven Hills, NSW, Australia; Accutracker 20 or Oscar 2, 21 Suntech Medical Instruments, Raleigh, NC, United States). Values were also assessed according to clock times with 07:00 to 23:00 being considered as day and 23:00 to 07:00 as night in two centres or according to patient reported sleep periods in nine centres (see Web Extra supplement for further details). In the majority of instances clinic blood was measured by non-medically qualified professional staff (research nurses and research staff) trained in the measurement of blood. Datasets from four centres included the referring doctor s clinic blood measurement; only those taken within two weeks of the ambulatory blood measurement (n=1593) were used for analysis. Clinic blood was measured after a 10 minute rest using an appropriately sized cuff and a mercury sphygmomanometer in all but three minor contributing centres (total 7.3% of the data), where a digital device (such as Dinamap or Omron) was used. For sphygmomanometer readings systolic and diastolic s were identified as the first and fifth Korotkoff sounds, respectively, which were elicited by deflating the cuff at a rate of 2 mm Hg per second. Depending on clinic protocols, blood was measured after at least 10 minutes in the seated position and also in the semi-recumbent position (45 on the examination couch). Sitting and reclining clinic measurements were available for 1260 participants. The average number of clinic measurements across the 11 centres was 2.8 readings with an average of 2.4 readings used per person if the initial measurement was excluded. We determined ambulatory blood equivalents for the lower limits of grade 3 (severe) hypertension (180/110 mm Hg), grade 2 (moderate) hypertension (160/ mm Hg), grade 1 (mild) hypertension (140/90 mm Hg); for target upper limits for hypertension with associated conditions (130/80 mm Hg) and hypertension with substantial proteinuria (125/75 mm Hg); and for the upper limit of optimal normal (120/80 mm Hg). These levels were chosen to encompass the recommendations by the National Heart Foundation of Australia, 8 the American Heart Association, 22 the European Society of Hypertension, 23 the British Hypertension Society, 24 BMJ ONLINE FIRST bmj.com

3 and the Canadian Hypertension Education Program. 25 Comparison between ambulatory equivalents for PAMELA study and Australian data We compared data from the PAMELA study 15 with our predicted ambulatory blood equivalents for the lower limits of grade one hypertension. We also undertook a comparison with the PAMELA data after exclusion from our dataset of participants treated with antihypertensive agents, restriction to the age range (25-64) used in PAMELA, and adjustment of the percentage of men to women to match that in PAMELA by removing a small proportion of women (3.3%) from the dataset at random but evenly across the age deciles. This resulted in a group of 1027 individuals with mean age, age range, and sex ratio identical to those in the PAMELA group. Statistical analysis Data are presented as mean (SD) of the between participant variation. Differences between groups were compared by Student s t test and were considered significant if P<0.05. We used ordinary least product linear regression equations between clinic and ambulatory blood values to generate ambulatory blood equivalents for target clinic values and to determine fixed and proportional bias using Table 1 Characteristics of patients by method of clinic blood measurement Staff measured blood (n=8529) Doctor measured blood (n=1593) Pfordifferences between groups Age in years 56.4 (15.4) 53.8 (15.9) <0.001 Age range Body mass index 28.9 (5.5) 28.9 (5.5) Female sex (%) 4626 (54%) 886 (56%) Treated hypertensives (%) 5866 (69%) 1138 (71%) White (%) 7026 (82%) 1313 (82%) Asian (%) 1290 (15%) 264 (17%) Office blood (mm Hg) Seated measurements Systolic seated (19.0) 1.2 (23.7) <0.001 Diastolic seated 81.7 (12.1) 88.8 (12.9) <0.001 Reclining measurements Systolic reclining (21.0) (22.8) <0.001 Diastolic reclining 83.8 (12.1) 88.7 (11.9) <0.001 Ambulatory blood (mm Hg) 24 hour systolic (14.6) (14.8) hour diastolic 76.6 (10.2) 77.3 (10.4) Day systolic (14.8) (15.0) Day diastolic 79.2 (10.6) 80.0 (10.9) Night systolic (17.0) (17.4) 0.9 Night diastolic 67.8 (10.3) 68.3 (10.9) Values presented as total, percentage of total, or mean (SD). SYSTAT 12 (Systat Software, Chicago, United States). Plots of residuals were used to determine homogeneity of variance. Further details of the method of analysis are included in the supplementary data. RESULTS Participants characteristics We recruited 8529 individuals from eleven hypertension referral centres; 4626 (54%) were women. The average age was 56 years (SD 16, range 14-98, median 57) and average body mass index was 28.9 kg/m 2 (SD 5.5). A large proportion were receiving medications for hypertension (n=5866, 69%) and most were white (n=7026, 82%). The mean seated clinic systolic/diastolic blood measured by trained staff was 142/ 82 mm Hg (SD 19/12) and mean reclining systolic/ diastolic blood was 142/84 mm Hg (21/12) (table 1). A smaller sample (n=1593) with measurements taken by doctors had similar characteristics to patients who had measurements taken by trained staff but their clinic measurements showed higher blood (P<0.001), seated systolic/diastolic blood (mean 1/89 mm Hg, SD 24/13), and reclining values (152/89 mm Hg, 23/12) (table 1). No differences in day, night, or 24 hour ambulatory systolic blood were noted between the two groups but ambulatory diastolic blood was slightly lower for the trained staff measurement group than the doctor measurement group (significantly so for 24 hour and daytime levels, table 1). Ambulatory equivalents for seated clinic blood measured by non-physician professional staff A least product regression analysis showed a high degree of association between seated clinic blood measured by trained staff and 24 hour, daytime, and night time ambulatory blood. The correlation was highest for daytime ambulatory blood values (r=0.64 for systolic and r=0.73 for diastolic blood ) and 24 hour ambulatory blood (r=0.64 systolic and r=0.73 diastolic; fig 1, supplementary table S1). Night time ambulatory blood values were less well correlated (r=0.49 and r=0.55). Slopes for least product regression in all cases were slightly less than 1 (range ) indicating proportional bias (95% confidence intervals for slope did not include 1) and fixed bias (95% confidence intervals for intercept for daytime and 24 hour regressions did not include zero) (supplementary table S1). In each case least product regression slopes were greater than least squares regression estimates (range ) and the least product regression lines followed closely the major axis of the ellipse of data points, unlike the least squares regression (figure). Residual plots showed uniform variance across predicted y (data not shown). The daytime systolic/diastolic ambulatory blood equivalent to the lower limit of grade 1 or mild hypertension was estimated to be 4/3 mm Hg lower than seated clinic values (table 2); the estimate for grade 2 hypertension was 8/4 mm Hg lower and for BMJ ONLINE FIRST bmj.com page 3 of 8

4 24 hour ambulatory blood (mm Hg) Intercept = 24.4 Slope = 0.77 r = 0.64 OLP LSR Intercept = 7.9 Slope = 0.85 r = Daytime ambulatory blood (mm Hg) Intercept = 25.4 Slope = 0.79 r = Intercept = 7.6 Slope = 0.88 r = Night time ambulatory blood (mm Hg) Intercept = -7.9 Slope = 0.92 r = Intercept = -1.9 Slope = 0.86 r = Clinic sitting systolic blood (mm Hg) Clinic sitting diastolic blood (mm Hg) Pearson correlation between seated clinic systolic and diastolic blood and 24 hour, daytime, and night time ambulatory blood measurements in 5327 participants for whom measurements were available. Dashed lines indicate least squares linear regression (LSR), straight lines indicate ordinary least product (OLP) linear regression. Intercept, slope, and correlation coefficient (r) is shown for each OLP regression grade 3 hypertension was 12/6 mm Hg lower. The equivalent target for ambulatory blood in patients with an associated condition or risk factor was 2/2 mm Hg lower than the seated clinic values and the equivalent for ambulatory blood in healthy people was 1/1 mm Hg lower. Daytime diastolic ambulatory blood equivalents were not affected by age but systolic equivalents were 2-4 mm Hg lower in people aged 65 years or older than in those aged years and 1-2 mm Hg lower than those aged Systolic and diastolic ambulatory blood equivalents were 3/2 mm Hg lower for women than for age matched men (table 3). When reclining estimates were used for clinic blood, Table 2 Systolic/diastolic ambulatory blood (ABP) values predicted from seated clinic blood levels; values in mm Hg Clinic blood threshold ABP predicted from staff measured seated clinic blood (n=5327) ABP predicted from doctor measured seated clinic blood (n=1490) 24 hour Night Day 24 hour Night Day Grade 3 (severe) hypertension >180/ / /93 168/ /95 143/86 155/98 Grade 2 (moderate) >160/ 148/93 139/84 152/96 138/86 128/78 142/90 hypertension Grade 1 (mild) hypertension >140/90 133/84 121/76 136/87 126/78 113/69 129/81 Target blood plus one <130/80 125/76 112/67 128/78 119/70 106/61 123/73 condition Target blood with <125/75 121/71 107/63 124/74 116/66 102/57 120/69 proteinuria Normal blood <120/80 117/76 102/67 120/78 113/70 99/61 117/70 page 4 of 8 BMJ ONLINE FIRST bmj.com

5 ambulatory equivalents were another 3-4 mm Hg lower (daytime -9/-6 for 140/90 mm Hg and -5/-4 for 130/80 mm Hg) (see supplementary table S2). Ambulatory equivalents for seated clinic blood measured by doctor In a separate analysis, we compared 1593 doctor measured clinic blood values with ambulatory blood by least product regression to determine whether ambulatory thresholds differed from those calculated using values measured by trained staff. The regression degree of correlation was somewhat lower in this group than in the larger group, with r values ranging from 0.41 to 0.54 (supplementary figure S1). While slopes and intercepts differed from 1 and zero respectively, indicating similar fixed and proportional bias to the main study, the least product regression lines followed the major axis of the data ellipsoid. The daytime systolic/diastolic ambulatory blood indicating the minimum for grade 1 hypertension was estimated to be 11/9 mm Hg lower than the equivalent clinic value (table 2); for target blood in patients with one condition the equivalent was 7/7 mm Hg lower, and for the upper limit of normal blood the equivalent was 3/10 mm Hg lower. In men and women the ambulatory equivalents for daytime diastolic were not affected by age, but those for systolic were lower in older people than in younger ones (table 3). Comparison between ambulatory equivalents for PAMELA study and Australian data Although the study populations differed in that clinic and ambulatory blood were lower for the PAMELA study than for the Australian data, even after adjustment for age, sex, and treatment status, the daytime ambulatory blood equivalents for doctor measured clinic blood of 140/90 mm Hg in PAMELA were almost identical to those in the present study (within 1 mm Hg; table 4). Limiting the Australian participants to match those of the PAMELA study by age, sex, and treatment status did not alter this value. Furthermore, the daytime ambulatory blood equivalents for trained staff measured clinic blood of 140/90 were 8/5 mm Hg higher than those of the PAMELA study and again were not affected by limiting the participants to match the criteria of the PAMELA study (10/5 mm Hg) (table 4). Comparison between clinic sitting and reclining blood To determine whether reclining clinic measurements could also be substituted for seated equivalents, we examined the relation between these two measurements in a subgroup of 1267 participants. There was a very high correlation between clinic blood measured sitting and reclining (r=0.85 for systolic blood and 0.81 for diastolic blood ). Diastolic blood s were effectively the same in either position since the slope and intercept 95% CIs overlapped with 1 and 0, respectively. Systolic blood s were slightly higher in the reclining than in the sitting position, but only at higher systolic blood values (3 mm Hg higher at 120 mm Hg and 5 mm Hg higher at 160 mm Hg, paired t test, P<0.0001, t=14). DISCUSSION We used least product regression to provide ambulatory blood equivalents for the definition of hypertension and its severity and for common treatment targets based on seated clinic measurements. When measurements were taken by trained staff, the daytime ambulatory blood equivalents for the lower limit of grade 1 hypertension (140/90 mm Hg) were 4/3 mm Hg lower than the clinic values. For the target clinic value in patients with one associated clinical condition (130/80 mm Hg) the daytime ambulatory blood equivalent was 2/2 mm Hg lower, and for patients with significant proteinuria who require a target clinic blood of 125/ 75 mm Hg, the daytime ambulatory equivalent was 1/1 mm Hg lower. Thus our analysis shows that the closer the patient s blood is to normal levels, the closer is the agreement between daytime ambulatory and clinic blood. On the other hand, the higher the blood, the greater the difference between ambulatory and clinic blood. Table 3 Daytime systolic/diastolic ambulatory blood s by age and sex predicted from seated clinic blood levels measured by staff; values in mm Hg Combined (n=5327) Men Women Clinic seated blood 24-hour Night Day (n=468) (n=1057) 65 (n=800) (n=616) (n=1112) 65 (n=1094) Grade 3 hypertension >180/ / /93 168/ / / / / / /102 Grade 2 hypertension >160/ 148/93 139/84 152/96 158/96 154/96 151/96 154/96 151/95 149/93 Grade 1 hypertension >140/90 133/84 121/76 136/87 140/87 138/88 136/87 137/87 135/86 133/85 Targetblood <130/80 125/76 112/67 128/78 131/79 130/79 128/79 129/78 126/77 125/77 plus one condition Targetblood <125/75 121/71 107/63 124/74 127/75 126/75 125/75 124/73 122/73 121/72 with proteinuria Normal blood <120/80 117/76 102/67 120/78 122/79 122/79 121/79 120/78 118/77 118/77 BMJ ONLINE FIRST bmj.com page 5 of 8

6 Table 4 Predicted systolic/diastolic ambulatory blood from PAMELA study and the present study measured by physician or staff, with and without age and treatment restrictions. Blood values in mm Hg. Present study: doctor measured Present study: staff measured PAMELA (n=1438) Combined seated (n=1490) Combined seated (age, sex, treatment adjusted) (n=112) Combined seated (n=5327) Combined seated (age, sex, treatment adjusted) (n=1027) Female sex.8% 833 (55.9%) 58 (.9%) 2888 (54.2%) 522 (.9%) Treated individuals excluded Yes No Yes No Yes Mean age in years (SD) 46.4 (11.9) 53.6 (15.8) 42.1 (10.7) 57.2 (15.9) 46.3 (10.2) Age range Clinic blood 128/82 1/89 146/91 142/82 137/87 Absolute ambulatory blood 24 hour 118/74 132/77 127/80 134/77 132/82 Daytime 123/79 136/80 132/83 137/80 136/85 Night time 108/64 121/68 113/68 122/68 117/71 Predicted ambulatory blood for grade 1 hypertension (clinic blood 140/90) 24 hour 123/77 126/78 123/78 133/84 134/85 Daytime 128/82 129/81 128/82 136/87 138/88 Daytime difference between 1/ 1 1/ 1 8/5 10/5 PAMELA and present study Night time 112/67 113/69 109/66 121/76 119/74 Comparison with other studies Previous studies have mainly concentrated on defining the upper limit of normal for ambulatory blood and have not extended the analysis to predictions for grade 2 (moderate) or grade 3 (severe) hypertension or to lower blood targets adjusted for comorbidities such as diabetes and renal disease. Consensus papers from an ad hoc committee of the American Society of Hypertension 26 and from the National Heart Foundation of Australia 11 have concluded that the daytime ambulatory blood equivalent for the lower limit of grade 1 hypertension (140/90) is 135/85 mm Hg, which is similar to but slightly less than the equivalent values of 136/87 mm Hg determined in the present study. The consensus papers have been mainly based on large, multicentre randomised population studies involving measurements from people considered normotensive 12 and from the PAMELA study of normotensive people from Monza, Italy. 15 The latter study predicted somewhat lower ambulatory blood equivalents than our study (for clinic 140/90 mm Hg, equivalents of 128/82 mm Hg for daytime and 125/ 80 mm Hg for 24 hour). Nevertheless, when we limited our data set to the same age range, excluded treated participants, and adjusted the male to female ratio to be identical to that of the PAMELA cohort, these changes made little difference to the predicted values. The main difference seems to arise from the fact that in the PAMELA study clinic blood was measured by doctors, since the differences between studies was almost eliminated when we used only the blood values measured by doctors. Therefore the most likely reason for our study showing greater equivalence between clinic and daytime ambulatory blood is that we have reduced the white coat effect by using clinic blood s measured by trained staff. Our finding that blood recorded by doctors was higher by 9/7 mm Hg than that recorded by other health professionals is in accord with previous studies that compared nurse and doctor measured blood. 27 A large study by La Batide- Alanore and colleagues showed that nurses recorded 6/8 mm Hg lower blood than doctors. 28 This finding led to the suggestion that routine management of the hypertensive patient should not rely solely on the doctor s assessment of blood. 28 Their finding that the nurse recorded blood was closer to the patient s daytime average ambulatory blood than the recorded by the doctor also closely concurs with the current study. One of the major differences between the population samples from our present study and previous reports is that we included a higher proportion of patients given antihypertensive medication who were referred for assessment of the effectiveness of treatment Little difference was observed in the predicted values when treated participants were excluded, suggesting that treatment does not significantly affect the relation between clinic and ambulatory blood measurements per se. These adjustments also included a slight change in the male to female ratio and age range but this does not indicate that age and sex were not important in the calculations of ambulatory blood equivalents. Estimates were 2-3 mm Hg lower for women than men for systolic and diastolic blood and lower in older participants of both sexes, but only for systolic blood. Thus more accurate ambulatory blood treatment targets may be attained by taking age and sex into consideration. Strengths and limitations of study A strength of the present study is that analyses were based on patients for whom treatment equivalents are page 6 of 8 BMJ ONLINE FIRST bmj.com

7 WHAT IS ALREADY KNOWN ON THIS TOPIC Ambulatory blood predicts cardiovascular outcome better than clinic blood, with known equivalent thresholds for diagnosis of mild hypertension Guidelines for management of hypertension in patients with pre-existing cardiovascular disease or risk factors suggest that target values should be different from those in patients without such factors, but ambulatory equivalents have not been defined Blood measured in the clinic by doctors tends to be higher than that measured by nurses WHAT THIS STUDY ADDS Regression analysis showed that the hypertension thresholds and target values for daytime ambulatory blood were slightly lower than the equivalent clinic values Ambulatory values were 1/2 mm Hg lower for women than for men and 3/1 mm Hg lower in older people ( 65 years) than in younger people Because doctors measurements of clinic blood were higher than those of trained staff, they are inappropriate for estimation of ambulatory blood treatment thresholds most relevant that is, with suspected or treated hypertension from 11 different hypertension clinics across all Australian states. Furthermore we also showed marked differences in the estimates depending on whether the clinic blood was measured by a doctor or a trained staff member. Another strength of the current study was the use of the least product method for regression estimates, which provides a statistically appropriate method for calculating ambulatory blood monitoring equivalence, particularly in cases where there is systematic and proportional bias (making the least squares method inappropriate). 29 This can be clearly appreciated by inspection of the regression lines and data distribution where the least product method, but not the least squares method, followed the major axis of the ellipsoid. A possible limitation of our study is that we have used the larger population (with and without comorbidities) in the regression analysis to predict target values for each, respectively. Thus a further future refinement would be to document and adjust for comorbidities and to determine whether this makes a significant difference in the predictive values. Conclusions and policy implications In conclusion, the present study provides a range of daytime ambulatory blood measurements equivalent to recognised diagnostic thresholds and target clinic blood. These values are only slightly below clinic values measured by trained staff and can be used to guide the management of hypertension. It also provides separate ambulatory blood targets for men and women at different ages. The benefits of this study are that we used blood measurements from both treated and untreated individuals, a population that is representative of clinical practice. Current hypertension guidelines propose operational thresholds for normality. We now suggest that the guidelines can include the thresholds identified in the current study to guide management of hypertension. This research is part of a joint initiative between the High Blood Pressure Research Council of Australia and the National Heart Foundation of Australia, which aims to support appropriate use and interpretation of ambulatory blood monitoring and effective management of blood in the primary care setting. Contributors: GAH was involved in study conception and design, study supervision, statistical analysis, preparation of graphs and tables, data interpretation, and drafting, revision, and finalising of the paper. ASM and KAD were involved in study conception and design, study supervision, data interpretation and drafting, revision, and finalising of the paper. NB, MAB,DC,PRCH,JH,AAM,BPM,MRN,andJESandwereinvolvedinstudy supervision, data interpretation, and revision and finalising of the paper. LJB, AJB, MS, and JPC and were involved in data interpretation and revision and finalising of the paper. JL was the study statistician and was involved in data analysis, drafting and revision of the paper. GAH is the guarantor. All authors had full access to all the data (including statistical reports and tables) in the study and take responsibility for the integrity of the data and the accuracy of the data analysis. We thank Kanella Chatzivlastou, Melinda Carrington, Carla M. Morley, Kim N Do, Karen Hall, Mark J Penny, Lai H Siew, and Agnes Ross for contributions to collection and analysis of data. Funding: Financial sponsorship was supplied to the first author, GAH, for the analysis of the data from the High Blood Pressure Research Council of Australia. All authors are members of the council. Competing interests: All authors have completed the Unified Competing Interest form, which is available on request from the corresponding author. The authors declare that (1) no authors have support from any company for the submitted work; (2) no authors have any relationships with companies that might have an interest in the submitted work in the previous 3 years; (3) their spouses, partners, or children have no financial relationships that may be relevant to the submitted work; and (4) no authors have non-financial interests that may be relevant to the submitted work. Ethical approval: Ethics committee approval was not required because we used anonymised data. Data sharing: no additional data available. 1 Khattar RS, Senior R, Swales JD, Lahiri A. Value of ambulatory intraarterial blood monitoring in the long-term prediction of left ventricular hypertrophy and carotid atherosclerosis in essential hypertension. J Hum Hypertens 1999;13: Williams B. The year in hypertension. JAmCollCardiol 2006;48: Sega R, Facchetti R, Bombelli M, Cesana G, Corrao G, Grassi G, et al. Prognostic value of ambulatory and home blood s compared with office blood in the general population: follow-up results from the Pressioni Arteriose Monitorate e Loro Associazioni (PAMELA) study. Circulation 2005;111: Staessen JA, Bieniaszewski L, O Brien E, Gosse P, Hayashi H, Imai Y, et al. Nocturnal blood fall on ambulatory monitoring in a large international database. The Ad Hoc Working Group. Hypertension 1997;29: Phillips RA, Butkevich A, Sheinart KF, Tuhrim S. Dipping is superior to cusums analysis in assessment of the risk of stroke in a case-control study. Am J Hypertens 2001;14: Verdecchia P, Schillaci G, Borgioni C, Ciucci A, Pede S, Porcellati C. Ambulatory pulse : a potent predictor of total cardiovascular risk in hypertension. Hypertension 1998;32: Zweiker R, Eber B, Schumacher M, Toplak H, Klein W. Non-dipping related to cardiovascular events in essential hypertensive patients. Acta Med Austriaca 1994;21: National Heart Foundation of Australia. Guide to management of hypertension Assessing and managing raised blood in adults SiteCollectionDocuments/ A_Hypert_Guidelines2008_2009Update_FINAL.pdf. 9 White WB. Ambulatory blood- monitoring in clinical practice. NEnglJMed2003;348: O Brien E, Coats A, Owens P, Petrie J, Padfield PL, Littler WA, et al. Use and interpretation of ambulatory blood monitoring: recommendations of the British Hypertension Society. BMJ 2000;320: McGrath BP. Ambulatory blood monitoring. Med J Aust 2002;176: Staessen JA, O Brien ET, Amery AK, Atkins N, Baumgart P, De Cort P, et al. Ambulatory blood in normotensive and hypertensive BMJ ONLINE FIRST bmj.com page 7 of 8

8 subjects: results from an international database. J Hypertens Suppl 1994;12:1-12S. 13 Kikuya M, Hansen TW, Thijs L, Bjorklund-Bodegard K, Kuznetsova T, Ohkubo T, etal. Diagnostic thresholdsforambulatory blood monitoring based on 10-year cardiovascular risk. Circulation 2007;115: Fagard RH, Celis H, Thijs L, Staessen JA, Clement DL, De Buyzere ML, et al. Daytime and nighttime blood as predictors of death and cause-specific cardiovascular events in hypertension. Hypertension 2008;51: Mancia G, Sega R, Bravi C, De Vito G, Valagussa F, Cesana G, et al. Ambulatory blood normality: results from the PAMELA study. JHypertens1995;13: Rasmussen SL, Torp-Pedersen C, Borch-Johnsen K, Ibsen H. Normal values for ambulatory blood and differences between casual blood and ambulatory blood : results from a Danish population survey. JHypertens1998;16: Bjorklund K, Lind L, Lithell H. Twenty-four hour ambulatory blood in a population of elderly men. JInternMed 2000;248: Schettini C, Bianchi M, Nieto F, Sandoya E, Senra H. Ambulatory blood : normality and comparison with other measurements. Hypertension Working Group. Hypertension 1999;34: O Brien E, Waeber B, Parati G, Staessen J, Myers MG. Blood measuring devices: recommendations of the European Society of Hypertension. BMJ 2001;322: Appel LJ, Whelton PK, Seidler AJ, Patel AR, Klag MJ. The accuracy and precision of the Accutracker ambulatory blood monitor. Am JEpidemiol1990;132: Jones SC, Bilous M, Winship S, Finn P, Goodwin J. Validation of the OSCAR 2 oscillometric 24-hour ambulatory blood monitor according to the international protocol for the validation of blood measuring devices. Blood Press Monit 2004;9: Pickering TG, Hall JE, Appel LJ, Falkner BE, Graves J, Hill MN, et al. Recommendations for blood measurement in humans and experimental animals: Part 1. Blood measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. Hypertension 2005;45: Mancia G, De Backer G, Dominiczak A, Cifkova R, Fagard R, Germano G, et al guidelines for the management of arterial hypertension: the task force for the management of arterial hypertension of the European Society of Hypertension (ESH) and of the European Society of Cardiology (ESC). JHypertens 2007;25: Williams B, Poulter NR, Brown MJ, Davis M, McInnes GT, Potter JF, et al. British Hypertension Society guidelines for hypertension management 2004 (BHS-IV): summary. BMJ 2004;328: Padwal RS, Hemmelgarn BR, McAlister FA, McKay DW, Grover S, Wilson T, et al. The 2007 Canadian Hypertension Education Program recommendations for the management of hypertension: part 1 blood measurement, diagnosis and assessment of risk. Can J Cardiol 2007;23: Pickering T. Recommendations for the use of home (self) and ambulatory blood monitoring. American Society of Hypertension Ad Hoc Panel. Am J Hypertens 1996;9: Mancia G, Parati G, Pomidossi G, Grassi G, Casadei R, Zanchetti A. Alerting reaction and rise in blood during measurement by physician and nurse. Hypertension 1987;9: La Batide-Alanore A, Chatellier G, Bobrie G, Fofol I, Plouin PF. Comparison of nurse- and physician-determined clinic blood levels in patients referred to a hypertension clinic: implications for subsequent management. JHypertens 2000;18: Ludbrook J. Comparing methods of measurement. Clin Exp Pharmacol Physiol 1997;24: Accepted: 18 January 2010 page 8 of 8 BMJ ONLINE FIRST bmj.com

Normal Ambulatory Blood Pressure: A Clinical-Practice- Based Analysis of Recent American Heart Association Recommendations

Normal Ambulatory Blood Pressure: A Clinical-Practice- Based Analysis of Recent American Heart Association Recommendations The American Journal of Medicine (2006) 119, 69.e13-69.e18 CLINICAL RESEARCH STUDY Normal Ambulatory Blood Pressure: A Clinical-Practice- Based Analysis of Recent American Heart Association Recommendations

More information

& Wilkins. a Division of Cardiology, Schulich Heart Centre, b Institute for Clinical and

& Wilkins. a Division of Cardiology, Schulich Heart Centre, b Institute for Clinical and Original article 333 Optimum frequency of office blood pressure measurement using an automated sphygmomanometer Martin G. Myers a, Miguel Valdivieso a and Alexander Kiss b,c Objective To determine the

More information

White-Coat and Masked Hypertension

White-Coat and Masked Hypertension White-Coat and Masked Hypertension Long-Term Risk of Sustained Hypertension in White-Coat or Masked Hypertension Giuseppe Mancia, Michele Bombelli, Rita Facchetti, Fabiana Madotto, Fosca Quarti-Trevano,

More information

Slide notes: References:

Slide notes: References: 1 2 3 Cut-off values for the definition of hypertension are systolic blood pressure (SBP) 135 and/or diastolic blood pressure (DBP) 85 mmhg for home blood pressure monitoring (HBPM) and daytime ambulatory

More information

How well do office and exercise blood pressures predict sustained hypertension? A Dundee Step Test Study

How well do office and exercise blood pressures predict sustained hypertension? A Dundee Step Test Study (2000) 14, 429 433 2000 Macmillan Publishers Ltd All rights reserved 0950-9240/00 $15.00 www.nature.com/jhh ORIGINAL ARTICLE How well do office and exercise blood pressures predict sustained hypertension?

More information

Prognostic significance of blood pressure measured in the office, at home and during ambulatory monitoring in older patients in general practice

Prognostic significance of blood pressure measured in the office, at home and during ambulatory monitoring in older patients in general practice (2005) 19, 801 807 & 2005 Nature Publishing Group All rights reserved 0950-9240/05 $30.00 www.nature.com/jhh ORIGINAL ARTICLE Prognostic significance of blood pressure measured in the office, at home and

More information

Use of ambulatory and home blood pressure (BP) measurements

Use of ambulatory and home blood pressure (BP) measurements Long-Term Risk of Mortality Associated With Selective and Combined Elevation in Office, Home, and Ambulatory Blood Pressure Giuseppe Mancia, Rita Facchetti, Michele Bombelli, Guido Grassi, Roberto Sega

More information

Protocol. Automated Ambulatory Blood Pressure Monitoring for the Diagnosis of Hypertension in Patients with Elevated Office Blood Pressure

Protocol. Automated Ambulatory Blood Pressure Monitoring for the Diagnosis of Hypertension in Patients with Elevated Office Blood Pressure Automated Ambulatory Blood Monitoring for the Diagnosis of Hypertension in Patients with Elevated Office Blood (10102) Medical Benefit Effective Date: 07/01/14 Next Review Date: 03/15 Preauthorization

More information

Journal of Hypertension 2004, 22: a Hypertension and Cardiovascular Rehabilitation Unit, Catholic University of

Journal of Hypertension 2004, 22: a Hypertension and Cardiovascular Rehabilitation Unit, Catholic University of Original article 81 Relationship between ambulatory blood pressure and followup clinic blood pressure in elderly patients with systolic hypertension Robert H. Fagard a, Jan A. Staessen a, Lutgarde Thijs

More information

a Hypertension and Cardiovascular Rehabilitation Unit, Faculty of Medicine, Received 2 June 2008 Revised 1 July 2008 Accepted 9 July 2008

a Hypertension and Cardiovascular Rehabilitation Unit, Faculty of Medicine, Received 2 June 2008 Revised 1 July 2008 Accepted 9 July 2008 Original article 325 Prognostic significance of ambulatory blood pressure in hypertensive patients with history of cardiovascular disease Robert H. Fagard a, Lutgarde Thijs a, Jan A. Staessen a, Denis

More information

and bias, which are known to be present in self-home and in professional office BP measurements taken using the auscultatory technique [7].

and bias, which are known to be present in self-home and in professional office BP measurements taken using the auscultatory technique [7]. Devices and technology 37 Validation of the A&D UM-11 professional hybrid device for office blood pressure measurement according to the International Protocol George S. Stergiou, Periklis P. Giovas, Charilaos

More information

Ambulatory blood pressure as a predictor of cardiovascular risk

Ambulatory blood pressure as a predictor of cardiovascular risk Review paper Ambulatory blood pressure as a predictor of cardiovascular risk Ankur Sethi, Rohit R. Arora Department of Cardiology, Rosalind Franklin University, Chicago Medical School, North Chicago, IL,

More information

The accurate measurement of blood pressure

The accurate measurement of blood pressure Position Paper ASH Position Paper: Home and Ambulatory Blood Pressure Monitoring When and How to Use Self (Home) and Ambulatory Blood Pressure Monitoring Thomas G. Pickering, MD, D Phil; 1 William B. White,

More information

ANTIHYPERTENSIVE DRUG THERAPY IN CONSIDERATION OF CIRCADIAN BLOOD PRESSURE VARIATION*

ANTIHYPERTENSIVE DRUG THERAPY IN CONSIDERATION OF CIRCADIAN BLOOD PRESSURE VARIATION* Progress in Clinical Medicine 1 ANTIHYPERTENSIVE DRUG THERAPY IN CONSIDERATION OF CIRCADIAN BLOOD PRESSURE VARIATION* Keishi ABE** Asian Med. J. 44(2): 83 90, 2001 Abstract: J-MUBA was a large-scale clinical

More information

Validation of the SEJOY BP-1307 upper arm blood pressure monitor for home. blood pressure monitoring according to the European Society of Hypertension

Validation of the SEJOY BP-1307 upper arm blood pressure monitor for home. blood pressure monitoring according to the European Society of Hypertension Validation of the SEJOY BP-1307 upper arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010 Short title: Validation

More information

ORIGINAL ARTICLE AMBULATORY BLOOD PRESSURE IN OBESITY. Introduction. Patients and Methods

ORIGINAL ARTICLE AMBULATORY BLOOD PRESSURE IN OBESITY. Introduction. Patients and Methods Vol. 2, Issue 1, pages 31-36 ORIGINAL ARTICLE AMBULATORY BLOOD PRESSURE IN OBESITY By Alejandro de la Sierra, MD Luis M. Ruilope, MD Hypertension Units, Hospital Clinico, Barcelona & Hospital 12 de Octubre,

More information

NIH Public Access Author Manuscript J Hum Hypertens. Author manuscript; available in PMC 2011 May 1.

NIH Public Access Author Manuscript J Hum Hypertens. Author manuscript; available in PMC 2011 May 1. NIH Public Access Author Manuscript Published in final edited form as: J Hum Hypertens. 2010 November ; 24(11): 749 754. doi:10.1038/jhh.2010.8. Long-Term Reproducibility of Ambulatory Blood Pressure is

More information

1 Department of Medical Physics, Royal Infirmary of Edinburgh, 2 Department of. Received 11 June 2004 Accepted 7 September 2004

1 Department of Medical Physics, Royal Infirmary of Edinburgh, 2 Department of. Received 11 June 2004 Accepted 7 September 2004 Devices and technology 1 Do SpaceLabs ambulatory non-invasive blood pressure recorders measure blood pressure consistently over several years use? John N. Amoore 1, David Dewar 2, Kathleen Gough 3 and

More information

Journal of the American College of Cardiology Vol. 46, No. 3, by the American College of Cardiology Foundation ISSN /05/$30.

Journal of the American College of Cardiology Vol. 46, No. 3, by the American College of Cardiology Foundation ISSN /05/$30. Journal of the American College of Cardiology Vol. 46, No. 3, 2005 2005 by the American College of Cardiology Foundation ISSN 0735-1097/05/$30.00 Published by Elsevier Inc. doi:10.1016/j.jacc.2005.03.070

More information

White coat and masked hypertension

White coat and masked hypertension White coat and masked hypertension Conflict of interest Support from Spacelabs, Microlife. Honoraria from Novartis, Elpen, Boeringer-Ingelheim, CANA, Lilly, MSD, Sanofi, Menarini, Ciezi, Astra-Zeneca.

More information

Does masked hypertension exist in healthy volunteers and apparently well-controlled hypertensive patients?

Does masked hypertension exist in healthy volunteers and apparently well-controlled hypertensive patients? O R I G I N A L A R T I C L E Does masked hypertension exist in healthy volunteers and apparently well-controlled hypertensive patients? I. Aksoy, J. Deinum, J.W.M. Lenders, Th. Thien *# Department of

More information

1. Department of Gynecology and Obstetrics, St. Joseph's Hospital Berlin Tempelhof, Germany

1. Department of Gynecology and Obstetrics, St. Joseph's Hospital Berlin Tempelhof, Germany Page 1 of 9 Validation of the TONOPORT VI ambulatory blood pressure monitor, according to the European Society of Hypertension International Protocol revision 2010 Michael Abou-Dakn 1, Cornelius Döhmen

More information

BRIEF COMMUNICATIONS. KEY WORDS: Ambulatory blood pressure monitoring, placebo effect, antihypertensive drug trials.

BRIEF COMMUNICATIONS. KEY WORDS: Ambulatory blood pressure monitoring, placebo effect, antihypertensive drug trials. AJH 1995; 8:311-315 BRIEF COMMUNICATIONS Lack of Placebo Effect on Ambulatory Blood Pressure Giuseppe Mancia, Stefano Omboni, Gianfranco Parati, Antonella Ravogli, Alessandra Villani, and Alberto Zanchetti

More information

Home and ambulatory blood pressure monitoring offers

Home and ambulatory blood pressure monitoring offers Monitoring Office, Home, and Ambulatory Blood Pressures as Predictors of Cardiovascular Risk Teemu J. Niiranen, Juhani Mäki, Pauli Puukka, Hannu Karanko, Antti M. Jula Abstract Ambulatory blood pressure

More information

The problem of uncontrolled hypertension

The problem of uncontrolled hypertension (2002) 16, S3 S8 2002 Nature Publishing Group All rights reserved 0950-9240/02 $25.00 www.nature.com/jhh The problem of uncontrolled hypertension Department of Public Health and Clinical Medicine, Norrlands

More information

Unreliable oscillometric blood pressure measurement: prevalence, repeatability and characteristics of the phenomenon

Unreliable oscillometric blood pressure measurement: prevalence, repeatability and characteristics of the phenomenon (2009) 23, 794 800 & 2009 Macmillan Publishers Limited All rights reserved 0950-9240/09 $32.00 www.nature.com/jhh ORIGINAL ARTICLE Unreliable oscillometric blood pressure measurement: prevalence, repeatability

More information

Nocturnal Hypertension or Nondipping: Which Is Better Associated With the Cardiovascular Risk Profile?

Nocturnal Hypertension or Nondipping: Which Is Better Associated With the Cardiovascular Risk Profile? Original Article Nocturnal Hypertension or Nondipping: Which Is Better Associated With the Cardiovascular Risk Profile? Alejandro de la Sierra, 1 Manuel Gorostidi, 2 José R. Banegas, 3 Julián Segura, 4

More information

Effects of Age on Arterial Stiffness and Blood Pressure Variables in Patients with Newly Diagnosed Untreated Hypertension

Effects of Age on Arterial Stiffness and Blood Pressure Variables in Patients with Newly Diagnosed Untreated Hypertension Original Article Print ISSN 1738-5520 On-line ISSN 1738-5555 Korean Circulation Journal Effects of Age on Arterial Stiffness and Blood Pressure Variables in Patients with Newly Diagnosed Untreated Hypertension

More information

Association of Isolated Systolic, Isolated Diastolic, and Systolic-Diastolic Masked Hypertension With Carotid Artery Intima-Media Thickness

Association of Isolated Systolic, Isolated Diastolic, and Systolic-Diastolic Masked Hypertension With Carotid Artery Intima-Media Thickness ORIGINAL PAPER Association of Isolated Systolic, Isolated Diastolic, and Systolic-Diastolic Masked Hypertension With Carotid Artery Intima-Media Thickness Efstathios Manios, MD; 1 Fotios Michas, MD; 1

More information

Copyright Lippincott Williams & Wilkins. Unauthorized reproduction of this article is prohibited.

Copyright Lippincott Williams & Wilkins. Unauthorized reproduction of this article is prohibited. Devices and technology 261 Validation of the ROSSMAX blood pressure measuring monitor according to the European Society of Hypertension International Protocol for Validation of Blood Pressure Measuring

More information

CLINICAL SCIENCE. Angela M. G. Pierin a, Edna C. Ignez a, Wilson Jacob Filho b, Alfonso Júlio Guedes Barbato b, Décio Mion Jr. b

CLINICAL SCIENCE. Angela M. G. Pierin a, Edna C. Ignez a, Wilson Jacob Filho b, Alfonso Júlio Guedes Barbato b, Décio Mion Jr. b CLINICS 2008;63(1):43-50 CLINICAL SCIENCE BLOOD PRESSURE MEASUREMENTS TAKEN BY PATIENTS ARE SIMILAR TO HOME AND AMBULATORY BLOOD PRESSURE MEASUREMENTS Angela M. G. Pierin a, Edna C. Ignez a, Wilson Jacob

More information

Statins, antihypertensive treatment, and blood pressure control in clinic and over 24 hours: evidence from PHYLLIS randomised double blind trial

Statins, antihypertensive treatment, and blood pressure control in clinic and over 24 hours: evidence from PHYLLIS randomised double blind trial The BMJ is an Open Access journal. We set no word limits on BMJ research articles, but they are abridged for print. The full text of each BMJ research article is freely available on bmj.com research KAREN

More information

Ambulatory Blood Pressure and Cardiovascular Events in Chronic Kidney Disease. Rajiv Agarwal, MD

Ambulatory Blood Pressure and Cardiovascular Events in Chronic Kidney Disease. Rajiv Agarwal, MD Ambulatory Blood Pressure and Cardiovascular Events in Chronic Kidney Disease Rajiv Agarwal, MD Summary: Hypertension is an important risk factor for adverse cardiovascular and renal outcomes, particularly

More information

Ambulatory Blood Pressure and Prognosis

Ambulatory Blood Pressure and Prognosis Ambulatory Blood Pressure and Prognosis Daytime and Nighttime Blood Pressure as Predictors of Death and Cause-Specific Cardiovascular Events in Hypertension Robert H. Fagard, Hilde Celis, Lutgarde Thijs,

More information

Ambulatory blood pressure monitoring (ABPM) is. Accuracy of Ambulatory Blood Pressure Monitors in Routine Clinical Practice.

Ambulatory blood pressure monitoring (ABPM) is. Accuracy of Ambulatory Blood Pressure Monitors in Routine Clinical Practice. AJH 26; 19:81 89 BP Measurement Accuracy of Ambulatory Blood Pressure Monitors in Routine Clinical Practice Tony C. Y. Pang and Mark A. Brown Background: To determine the extent of discrepancies between

More information

Medical Policy An Independent Licensee of the Blue Cross and Blue Shield Association

Medical Policy An Independent Licensee of the Blue Cross and Blue Shield Association Ambulatory Blood Pressure Monitoring Page 1 of 14 Medical Policy An Independent Licensee of the Blue Cross and Blue Shield Association Title: Ambulatory Blood Pressure Monitoring Professional Institutional

More information

Automated Ambulatory Blood Pressure Monitoring for the Diagnosis of Hypertension in Patients with Elevated Office Blood Pressure

Automated Ambulatory Blood Pressure Monitoring for the Diagnosis of Hypertension in Patients with Elevated Office Blood Pressure Automated Ambulatory Blood Pressure Monitoring for the Diagnosis of Hypertension in Patients with Elevated Office Blood Pressure Policy Number: 1.01.02 Last Review: 9/2014 Origination: 1/1989 Next Review:

More information

Drug treatments in hypertension outcome studies

Drug treatments in hypertension outcome studies The Second Australian National Blood Pressure Study Page 1 of 6 Background Outcome of treatment of hypertension Over the past 25 years studies of the drug treatment of mild-moderate hypertension have demonstrated

More information

Hypertension. Diagnostic Thresholds for Ambulatory Blood Pressure Monitoring Based on 10-Year Cardiovascular Risk

Hypertension. Diagnostic Thresholds for Ambulatory Blood Pressure Monitoring Based on 10-Year Cardiovascular Risk Diagnostic Thresholds for Ambulatory Blood Pressure Monitoring Based on 10-Year Cardiovascular Risk Masahiro Kikuya, MD, PhD; Tine W. Hansen, MD, PhD; Lutgarde Thijs, MSc; Kristina Björklund-Bodegård,

More information

DEVICES AND TECHNOLOGY

DEVICES AND TECHNOLOGY DEVICES AND TECHNOLOGY Validation of a new algorithm for the BPM-100 electronic oscillometric office blood pressure monitor James M. Wright ab, Gurdial S. Mattu a, Thomas L. Perry Jr ab, Mark E. Gelfer

More information

Home blood pressure measurement with oscillometric upper-arm devices

Home blood pressure measurement with oscillometric upper-arm devices REVIEW Home blood pressure measurement with oscillometric upper-arm devices R.L. Braam, Th. Thien *# Department of Internal Medicine, University Medical Centre St Radboud, PO Box 9101, 6500 HB Nijmegen,

More information

Copyright Lippincott Williams & Wilkins. Unauthorized reproduction of this article is prohibited.

Copyright Lippincott Williams & Wilkins. Unauthorized reproduction of this article is prohibited. Devices and technology 223 Validation of the A&D UA-705 device for self-measurement of blood pressure according to the British Hypertension Society protocol Paolo Verdecchia, Fabio Angeli, Roberto Gattobigio,

More information

This article will focus on the role of the following in BP management and their prognostic significance:

This article will focus on the role of the following in BP management and their prognostic significance: CARDIOVASCULAR DISORDERS UNIT NO. 2 HOME BLOOD PRESSURE MONITORING, BLOOD PRESSURE VARIABILITY AND MORNING BLOOD PRESSURE SURGE Dr Rohit Khurana, Dr Lucy Priestner ABSTRACT Hypertension is a common chronic

More information

Protocol. Automated Ambulatory Blood Pressure Monitoring for the Diagnosis of Hypertension in Patients With Elevated Office Blood Pressure

Protocol. Automated Ambulatory Blood Pressure Monitoring for the Diagnosis of Hypertension in Patients With Elevated Office Blood Pressure Automated Ambulatory Blood Monitoring for the Diagnosis of Hypertension in Patients With Elevated Office Blood (10102) Medical Benefit Effective Date: 07/01/14 Next Review Date: 03/18 Preauthorization

More information

RESEARCH INTRODUCTION

RESEARCH INTRODUCTION Conventional versus automated measurement of blood pressure in primary care patients with systolic hypertension: randomised parallel design controlled trial Martin G Myers, professor of medicine, 1 Marshall

More information

Time of day for exercise on blood pressure reduction in dipping and nondipping hypertension

Time of day for exercise on blood pressure reduction in dipping and nondipping hypertension (2005) 19, 597 605 & 2005 Nature Publishing Group All rights reserved 0950-9240/05 $30.00 www.nature.com/jhh ORIGINAL ARTICLE on blood pressure reduction in dipping and nondipping hypertension S Park,

More information

Indirect ambulatory blood pressure monitoring devices

Indirect ambulatory blood pressure monitoring devices AJH 1992;5:880-886 Comparison of Ambulatory and Clinic Blood Pressure and Heart Rate in Older Persons With Isolated Systolic Hypertension Gale H. Rutan, Robert H. McDonald, and Lewis H. Kuller We compared

More information

Arm position and blood pressure: a risk factor for hypertension?

Arm position and blood pressure: a risk factor for hypertension? (3) 17, 389 395 & 3 Nature Publishing Group All rights reserved 09-9240/03 $25.00 www.nature.com/jhh ORIGINAL ARTICLE Arm position and blood pressure: a risk factor for hypertension? A Mourad, S Carney,

More information

Methods DEVICES AND TECHNOLOGY

Methods DEVICES AND TECHNOLOGY DEVICES AND TECHNOLOGY Validation of the Omron HEM-907 device for blood pressure measurement Mohamed A. El Assaad, Jirar A. Topouchian, Bernadette M. Darné and Roland G. Asmar Background The aim of this

More information

Ambulatory blood pressure measurement (ABPM) is being used increasingly in clinical practice.

Ambulatory blood pressure measurement (ABPM) is being used increasingly in clinical practice. Hypertension AMBULATORY BLOOD PRESSURE MONITORING IN THE MANAGEMENT OF HYPERTENSION c WHY Correspondence to: Professor Eoin O Brien, Blood Pressure Unit and ADAPT Centre, Beaumont Hospital, Dublin 9, Ireland;

More information

The increasing awareness of hypertension as a serious

The increasing awareness of hypertension as a serious AJH 2002; 15:787 792 Evaluation of the Performance of a Wrist Blood Pressure Measuring Device With a Position Sensor Compared to Ambulatory 24-Hour Blood Pressure Measurements Sakir Uen, Burkard Weisser,

More information

Ambulatory Blood Pressure Monitoring Clinical Practice Recommendations

Ambulatory Blood Pressure Monitoring Clinical Practice Recommendations Acta Medica Marisiensis 2016;62(3):350-355 DOI: 10.1515/amma-2016-0038 UPDATE Ambulatory Blood Pressure Monitoring Clinical Practice Recommendations Mako Katalin *, Ureche Corina, Jeremias Zsuzsanna University

More information

Comparison of arbitrary definitions of circadian time periods with those determined by wrist actigraphy in analysis of ABPM data

Comparison of arbitrary definitions of circadian time periods with those determined by wrist actigraphy in analysis of ABPM data Journal of Human Hypertension (1999) 13, 449 453 1999 Stockton Press. All rights reserved 0950-9240/99 $12.00 http://www.stockton-press.co.uk/jhh ORIGINAL ARTICLE Comparison of arbitrary definitions of

More information

IDENTIFYING MASKED UNCONTROLLED HYPERTENSION IN THE. RUNNING HEAD: Factors associated with masked uncontrolled hypertension.

IDENTIFYING MASKED UNCONTROLLED HYPERTENSION IN THE. RUNNING HEAD: Factors associated with masked uncontrolled hypertension. IDENTIFYING MASKED UNCONTROLLED HYPERTENSION IN THE COMMUNITY PHARMACY SETTING RUNNING HEAD: Factors associated with masked uncontrolled hypertension. Authors, on behalf of the MEPAFAR study workgroup:

More information

Assessing Blood Pressure for Clinical Research: Pearls & Pitfalls

Assessing Blood Pressure for Clinical Research: Pearls & Pitfalls Assessing Blood Pressure for Clinical Research: Pearls & Pitfalls Anthony J. Viera, MD, MPH, FAHA Department of Family Medicine Hypertension Research Program UNC School of Medicine Objectives Review limitations

More information

Todd S. Perlstein, MD FIFTH ANNUAL SYMPOSIUM

Todd S. Perlstein, MD FIFTH ANNUAL SYMPOSIUM Todd S. Perlstein, MD FIFTH ANNUAL SYMPOSIUM Faculty Disclosure I have no financial interest to disclose No off-label use of medications will be discussed FIFTH ANNUAL SYMPOSIUM Recognize changes between

More information

Primary hypertension in adults

Primary hypertension in adults Primary hypertension in adults NICE provided the content for this booklet which is independent of any company or product advertised Hypertension Welcome NICE published an updated guideline on the diagnosis

More information

Copyright Lippincott Williams & Wilkins. Unauthorized reproduction of this article is prohibited.

Copyright Lippincott Williams & Wilkins. Unauthorized reproduction of this article is prohibited. Devices and technology 57 Comparison of wrist-type and arm-type 24-h blood pressure monitoring devices for ambulatory use Takahiro Komori a, Kazuo Eguchi a, Satoshi Hoshide a, Bryan Williams b and Kazuomi

More information

Clinical Implications of Ambulatory and Home Blood Pressure Monitoring

Clinical Implications of Ambulatory and Home Blood Pressure Monitoring REVIEW DOI 10.4070 / kcj.2010.40.9.423 Print ISSN 1738-5520 / On-line ISSN 1738-5555 Copyright 2010 The Korean Society of Cardiology Open Access Clinical Implications of Ambulatory and Home Blood Pressure

More information

THE NEW ARMENIAN MEDICAL JOURNAL DISTRIBUTION, AWARENESS, TREATMENT, AND CONTROL OF ARTERIAL HYPERTENSION IN YEREVAN (ARMENIA)

THE NEW ARMENIAN MEDICAL JOURNAL DISTRIBUTION, AWARENESS, TREATMENT, AND CONTROL OF ARTERIAL HYPERTENSION IN YEREVAN (ARMENIA) THE NEW ARMENIAN MEDICAL JOURNAL Vol.5 (2011), Nо 2, p.29-34 DISTRIBUTION, AWARENESS, TREATMENT, AND CONTROL OF ARTERIAL HYPERTENSION IN YEREVAN (ARMENIA) Zelveian P.H. 1, 2, Podosyan G.A. 2 1 Institute

More information

The Working Group on Blood Pressure Monitoring of

The Working Group on Blood Pressure Monitoring of Brief Review Ambulatory Blood Pressure Measurement What Is the International Consensus? The Working Group on Blood Pressure Monitoring of the European Society of Hypertension (ESH) published recommendations

More information

STATE OF THE ART BP ASSESSMENT

STATE OF THE ART BP ASSESSMENT STATE OF THE ART BP ASSESSMENT PROFESSOR MOLECULAR PHARMACOLOGY CONWAY INSTITUE UNIVERSITY COLLEGE DUBLIN CO-CHAIRMAN BLOOD PRESCSURE MANAGEMENT IN LOW RESOURCE SETTINGS CENTRE FOR INTERNATIONAL HUMANITARIAN

More information

ORIGINAL INVESTIGATION. Blunted Heart Rate Dip During Sleep and All-Cause Mortality. clinical practice and in hypertension

ORIGINAL INVESTIGATION. Blunted Heart Rate Dip During Sleep and All-Cause Mortality. clinical practice and in hypertension ORIGINAL INVESTIGATION Blunted Heart Rate Dip During Sleep and All-Cause Mortality Iddo Z. Ben-Dov, MD; Jeremy D. Kark, MD; Drori Ben-Ishay, MD; Judith Mekler, MSc; Liora Ben-Arie; Michael Bursztyn, MD

More information

Comparison of manual versus automated blood pressure measurement in intensive care unit, coronary care unit, and emergency room.

Comparison of manual versus automated blood pressure measurement in intensive care unit, coronary care unit, and emergency room. Comparison of manual versus automated blood pressure measurement in intensive care unit, coronary care unit, and emergency room Abstract Ahmad Mirdamadi (1), Mostafa Etebari (2) Original Article BACKGROUND:

More information

DR JIRAR TOPOUCHIAN PROF PAROUNAK ZELVEIAN PROF ROLAND ASMAR. September 8 th, Principal Investigator and Study Chair:

DR JIRAR TOPOUCHIAN PROF PAROUNAK ZELVEIAN PROF ROLAND ASMAR. September 8 th, Principal Investigator and Study Chair: Page 1 of 10 Validation of the automatic blood pressure measurements device, the OMRON EVOLV (HEM- 7600 T-E) in Pregnancy according to the Modified European Society of Hypertension International Protocol

More information

MEDICAL POLICY SUBJECT: AUTOMATED AMBULATORY BLOOD PRESSURE MONITORING

MEDICAL POLICY SUBJECT: AUTOMATED AMBULATORY BLOOD PRESSURE MONITORING MEDICAL POLICY SUBJECT: AUTOMATED AMBULATORY 02/19/09 PAGE: 1 OF: 5 If a product excludes coverage for a service, it is not covered, and medical policy criteria do not apply. If a commercial product, including

More information

Received 24 February 2015 Revised 29 April 2015 Accepted 20 May 2015

Received 24 February 2015 Revised 29 April 2015 Accepted 20 May 2015 Original article 1 Clinical practice of ambulatory versus home blood pressure monitoring in hypertensive patients Jorge A. Paolasso, Florencia Crespo, Viviana Arias, Eduardo A. Moreyra, Ariel Volmaro,

More information

Masked Hypertension: A Review

Masked Hypertension: A Review 479 Review Hypertens Res Vol.30 (2007) No.6 p.479-488 Masked Hypertension: A Review Thomas G. PICKERING 1), Kazuo EGUCHI 1),2), and Kazuomi KARIO 2) Masked hypertension is defined as a normal blood pressure

More information

greater than 90% of patients having blood pressure measured consistently according to the protocol.

greater than 90% of patients having blood pressure measured consistently according to the protocol. Clinical methods and pathophysiology 1 Reliability and validity of blood pressure measurement in the Secondary Prevention of Small Subcortical Strokes study Pablo E. Pérgola a, Carole L. White b, John

More information

Levels of Office Blood Pressure and Their Operating Characteristics for Detecting Masked Hypertension Based on Ambulatory Blood Pressure Monitoring

Levels of Office Blood Pressure and Their Operating Characteristics for Detecting Masked Hypertension Based on Ambulatory Blood Pressure Monitoring Original Article Levels of Office Blood Pressure and Their Operating Characteristics for Detecting Masked Hypertension Based on Ambulatory Blood Pressure Monitoring Anthony J. Viera, 1,2 Feng-Chang Lin,

More information

Ambulatory BP Monitoring: Getting the Diagnosis of Hypertension Right. Anthony J. Viera, MD, MPH, FAHA Professor and Chair

Ambulatory BP Monitoring: Getting the Diagnosis of Hypertension Right. Anthony J. Viera, MD, MPH, FAHA Professor and Chair Ambulatory BP Monitoring: Getting the Diagnosis of Hypertension Right Anthony J. Viera, MD, MPH, FAHA Professor and Chair Objectives Review limitations of office BP in making a correct diagnosis of hypertension

More information

Ambulatory blood pressure (ABP) may be normal in

Ambulatory blood pressure (ABP) may be normal in Response to Antihypertensive Therapy in Older Patients With Sustained and Nonsustained Systolic Hypertension Robert H. Fagard, MD; Jan A. Staessen, MD; Lutgarde Thijs, BSc; Jerzy Gasowski, MD; Christopher

More information

Validation of the OMRON 705 IT blood pressure measuring device according to the International Protocol of the European Society of Hypertension

Validation of the OMRON 705 IT blood pressure measuring device according to the International Protocol of the European Society of Hypertension Validation of the OMRON 705 IT blood pressure measuring device according to the International Protocol of the European Society of Hypertension M. EL ASSAAD, J. TOPOUCHIAN, G. LABAKI, R. ASMAR L Institut

More information

ARIC Manuscript Proposal # 947. PC Reviewed: 07/01/03 Status: A Priority: 2 SC Reviewed: 07/18/03 Status: A Priority: 2

ARIC Manuscript Proposal # 947. PC Reviewed: 07/01/03 Status: A Priority: 2 SC Reviewed: 07/18/03 Status: A Priority: 2 ARIC Manuscript Proposal # 947 PC Reviewed: 07/01/03 Status: A Priority: 2 SC Reviewed: 07/18/03 Status: A Priority: 2 1.a. Full Title: The Impact of Treatment and Adequate Control of Blood Pressure for

More information

Ambulatory blood pressure measurement is now indispensable to the good clinical management of hypertension

Ambulatory blood pressure measurement is now indispensable to the good clinical management of hypertension CARDIOVASCULAR JOURNAL OF SOUTH AFRICA Vol 14, No. 3, May/June 2003 113 Editorial Ambulatory blood pressure measurement is now indispensable to the good clinical management of hypertension Ambulatory blood

More information

White coat hypertension, which

White coat hypertension, which H Y P E R T E N S I O N A N D D I A B E T E S D E B A T E S Should White-Coat Hypertension in Diabetes Be Treated? Pro GIUSEPPE MANCIA, MD 1 ROBERTO SEGA, MD 1 MICHELE BOMBELLI, MD 1 White coat hypertension,

More information

Masked Hypertension and Prehypertension: Diagnostic Overlap and Interrelationships With Left Ventricular Mass: The Masked Hypertension Study

Masked Hypertension and Prehypertension: Diagnostic Overlap and Interrelationships With Left Ventricular Mass: The Masked Hypertension Study original contributions nature publishing group Masked Hypertension and Prehypertension: Diagnostic Overlap and Interrelationships With Left Ventricular Mass: The Masked Hypertension Study Daichi Shimbo

More information

BLOOD PRESSURE MEASUREMENT HOME BASED OR OFFICE BP MONITORING WHICH, HOW AND WHEN?

BLOOD PRESSURE MEASUREMENT HOME BASED OR OFFICE BP MONITORING WHICH, HOW AND WHEN? BLOOD PRESSURE MEASUREMENT HOME BASED OR OFFICE BP MONITORING WHICH, HOW AND WHEN? DECLARATION OF INTEREST Medical Director and Chairman, Advisory Board dabl Ltd., Dublin, Ireland. BLOOD PRESSURE MEASUREMENT

More information

HOW CONSISTENT ARE THE BLOOD PRESSURE AND PULSE RATE MEASUREMENTS OF THE ELECTRONIC BP APPARATUS AND THE MANUAL SPHYGMOMANOMETER

HOW CONSISTENT ARE THE BLOOD PRESSURE AND PULSE RATE MEASUREMENTS OF THE ELECTRONIC BP APPARATUS AND THE MANUAL SPHYGMOMANOMETER HOW CONSISTENT ARE THE BLOOD PRESSURE AND PULSE RATE MEASUREMENTS OF THE ELECTRONIC BP APPARATUS AND THE MANUAL SPHYGMOMANOMETER Naser KA. Teaching Hospital Peradeniya, Peradeniya, Sri Lanka Zawahir S

More information

Evaluation of the Extent and Duration of the ABPM Effect in Hypertensive Patients

Evaluation of the Extent and Duration of the ABPM Effect in Hypertensive Patients Journal of the American College of Cardiology Vol. 40, No. 4, 2002 2002 by the American College of Cardiology Foundation ISSN 0735-1097/02/$22.00 Published by Elsevier Science Inc. PII S0735-1097(02)02011-9

More information

Use and Interpretation of Home Blood Pressure Monitoring

Use and Interpretation of Home Blood Pressure Monitoring Use and Interpretation of Home Blood Pressure Monitoring BLOOD PRESSURE in year 2015 PARAMETERS TODAY Gianfranco Parati University of Milano-Bicocca & Ospedale S.Luca, IRCCS, Istituto Auxologico Italiano

More information

a Centre de Médecine Cardiovasculaire, Paris, France, b Lebanese Hospital and Received 7 June 2009 Revised 15 September 2009 Accepted 9 October 2009

a Centre de Médecine Cardiovasculaire, Paris, France, b Lebanese Hospital and Received 7 June 2009 Revised 15 September 2009 Accepted 9 October 2009 42 Original article Validation of three professional devices measuring office blood pressure according to three different methods: the Omron BP, the Omron HBP T and the Pic Indolor Professional Roland

More information

Evaluation of the Accutracker I1 noninvasive ambulatory blood pressure recorder according to the AAMI Standard

Evaluation of the Accutracker I1 noninvasive ambulatory blood pressure recorder according to the AAMI Standard Evaluation of the Accutracker I1 noninvasive ambulatory blood pressure recorder according to the AAMI Standard EOIN O'BRIENt, NEIL ATKINS, JAMES SHERIDAN, COLM KILLEEN, RICHARD COSTELLOE, SHANE LYDON and

More information

Automated Ambulatory Blood Pressure Monitoring for the Diagnosis of Hypertension in Patients with Elevated Office Blood Pressure

Automated Ambulatory Blood Pressure Monitoring for the Diagnosis of Hypertension in Patients with Elevated Office Blood Pressure Automated Ambulatory Blood Pressure Monitoring for the Diagnosis of Hypertension in Patients with Elevated Office Blood Pressure Policy Number: 1.01.02 Last Review: 9/2018 Origination: 1/1989 Next Review:

More information

Importance of Ambulatory Blood Pressure Monitoring in Adolescents

Importance of Ambulatory Blood Pressure Monitoring in Adolescents Importance of Ambulatory Blood Pressure Monitoring in Adolescents Josep Redon, MD, PhD, FAHA Internal Medicine Hospital Clinico Universitario de Valencia University of Valencia CIBERObn Instituto de Salud

More information

CONGESTIVE HEART FAILURE

CONGESTIVE HEART FAILURE ORIGINAL CONTRIBUTION Diurnal Blood Pressure Pattern and Risk of Congestive Heart Failure Erik Ingelsson, MD, PhD Kristina Björklund-Bodegård, MD, PhD Lars Lind, MD, PhD Johan Ärnlöv, MD, PhD Johan Sundström,

More information

Clinical Significance and Treatment Requirements in White Coat and Masked Hypertension

Clinical Significance and Treatment Requirements in White Coat and Masked Hypertension Clinical Significance and Treatment Requirements in White Coat and Masked Hypertension 2 Jean-Michel Mallion 2.1 Introduction The phenomena of white coat hypertension (WCHT) and masked hypertension (MH)

More information

DIFFERENTE RELAZIONE TRA VALORI PRESSORI E MASSA VENTRICOLARE SX NEI DUE SESSI IN PAZIENTI IPERTESI.

DIFFERENTE RELAZIONE TRA VALORI PRESSORI E MASSA VENTRICOLARE SX NEI DUE SESSI IN PAZIENTI IPERTESI. DIFFERENTE RELAZIONE TRA VALORI PRESSORI E MASSA VENTRICOLARE SX NEI DUE SESSI IN PAZIENTI IPERTESI. Franco Cipollini, Carlo Porta, Enrica Arcangeli, Carla Breschi, & Giuseppe Seghieri Azienda USL 3, Ambulatorio

More information

The magnitude and duration of ambulatory blood pressure reduction following acute exercise

The magnitude and duration of ambulatory blood pressure reduction following acute exercise Journal of Human Hypertension (1999) 13, 361 366 1999 Stockton Press. All rights reserved 0950-9240/99 $12.00 http://www.stockton-press.co.uk/jhh ORIGINAL ARTICLE The magnitude and duration of ambulatory

More information

Carlos A. Segre, Rubens K. Ueno, Karim R. J. Warde, Tarso A. D. Accorsi, Márcio H. Miname, Chang K. Chi, Angela M. G. Pierin, Décio Mion Júnior

Carlos A. Segre, Rubens K. Ueno, Karim R. J. Warde, Tarso A. D. Accorsi, Márcio H. Miname, Chang K. Chi, Angela M. G. Pierin, Décio Mion Júnior Original Article White-coat Hypertension and Normotension in the League of Hypertension of the Hospital das Clínicas, FMUSP. Prevalence, Clinical and Demographic Characteristics Carlos A. Segre, Rubens

More information

An Observational Study: Ambulatory Blood Pressure Monitoring after Percutaneous Transluminal Coronary Angioplasty

An Observational Study: Ambulatory Blood Pressure Monitoring after Percutaneous Transluminal Coronary Angioplasty THIEME Original Article 17 An Observational Study: Ambulatory Blood Pressure Monitoring after Percutaneous Transluminal Coronary Angioplasty Gopi Krishna Kenchi 1 Sunisha Gajula 2 Malleshwar Rao Dangati

More information

Prognostic accuracy of day versus night ambulatory blood pressure: a cohort study

Prognostic accuracy of day versus night ambulatory blood pressure: a cohort study Prognostic accuracy of day versus night ambulatory blood pressure: a cohort study José Boggia,* Yan Li,* Lutgarde Thijs, Tine W Hansen, Masahiro Kikuya, Kristina Björklund-Bodegård, Tom Richart, Takayoshi

More information

a Medical Physics Department, Guy s & St Thomas NHS Foundation Trust and b King s College School of Medicine, St Thomas Campus, London, UK

a Medical Physics Department, Guy s & St Thomas NHS Foundation Trust and b King s College School of Medicine, St Thomas Campus, London, UK Devices and technology 27 Validation of the Omron 705IT (HEM-759-E) oscillometric blood pressure monitoring device according to the British Hypertension Society protocol Andrew Coleman a, Paul Freeman

More information

There is convincing evidence in clinical studies

There is convincing evidence in clinical studies AJH 1998;11:1413 1417 Reliability of Reporting Self-Measured Blood Pressure Values by Hypertensive Patients Thomas Mengden, Rosa Maria Hernandez Medina, Belen Beltran, Elena Alvarez, Karin Kraft, and Hans

More information

24-Hour Ambulatory Blood Pressure Monitoring

24-Hour Ambulatory Blood Pressure Monitoring No. 15 Jan 2003 Before CCO decides to undertake a health technology assessment, a pre-assessment of the literature is performed. Pre-assessments are based on a limited literature search; they are not extensive,

More information

Comparison of two oscillometric blood pressure monitors in subjects with atrial fibrillation

Comparison of two oscillometric blood pressure monitors in subjects with atrial fibrillation ORIGINAL RESEARCH Comparison of two oscillometric blood pressure monitors in subjects with atrial fibrillation Tyler S Lamb BSc Amar Thakrar MD, FRCPC Mahua Ghosh MD, PhD Merne P Wilson MSc Thomas W Wilson

More information

Prognostic Value of Different Indices of Blood Pressure Variability in Hypertensive Patients

Prognostic Value of Different Indices of Blood Pressure Variability in Hypertensive Patients articles nature publishing group Prognostic Value of Different Indices of Blood Pressure Variability in Hypertensive Patients Sante D. Pierdomenico 1,2, Marta Di Nicola 3, Anna L. Esposito 3, Rocco Di

More information

Declaration of conflict of interest

Declaration of conflict of interest Declaration of conflict of interest Prevalence and main features of resistant hypertension in Central and Eastern Europe: data from the G. Brambilla 1, G. Seravalle 2, R. Cifkova 3, C. Farsang 4, S. Laurent

More information

DIURNAL VARIATIONS IN BLOOD PRESSURE AND THEIR RELATION WITH CAROTID ARTERY INTIMA-MEDIA THICKENING

DIURNAL VARIATIONS IN BLOOD PRESSURE AND THEIR RELATION WITH CAROTID ARTERY INTIMA-MEDIA THICKENING DIURNAL VARIATIONS IN BLOOD PRESSURE AND THEIR RELATION WITH CAROTID ARTERY INTIMA-MEDIA THICKENING Sh Narooei (1), B Soroor (2), F Zaker (3) Abstract INTRODUCTION: Hypertension is a very common cardiovascular

More information

DECLARATION OF CONFLICT OF INTEREST. None to declare

DECLARATION OF CONFLICT OF INTEREST. None to declare DECLARATION OF CONFLICT OF INTEREST None to declare Sympathetic nerve traffic, insulin resistance and baroreflex control of circulation in patients with resistant hypertension Gino Seravalle Marco Volpe

More information