Assessment of radiolucent lines around the Oxford unicompartmental knee replacement

Size: px
Start display at page:

Download "Assessment of radiolucent lines around the Oxford unicompartmental knee replacement"

Transcription

1 KNEE Assessment of radiolucent lines around the Oxford unicompartmental knee replacement SENSITIVITY AND SPECIFICITY FOR LOOSENING S. Kalra, T. O. Smith, B. Berko, N. P. Walton From Norfolk and Norwich University Hospital Trust, Norwich, England The Oxford unicompartmental knee replacement gives good results in patients with symptomatic osteoarthritis of the medial compartment. Previous studies have suggested that the presence of radiolucent lines (RLLs) does not reflect a poor outcome in such patients. However, the reliability and validity of this assessment have not been determined. Our aim was to assess the intra- and interobserver reliability and the sensitivity and specificity of the assessment of RLLs around both tibial and femoral components using standard radiographs. Two reviewers assessed the radiographs of 45 patients who had loosening of the tibial or femoral component confirmed at revision surgery and compared them with those of a series of 45 asymptomatic patients matched for age and gender. The results suggested that, using standard radiographs, tibial RLLs were 63.6% sensitive and 94.4% specific and femoral RLLs 63.9% sensitive and 72.7% specific for loosening. Overall intra- and interobserver reliability was highly variable, but zonal analysis showed that lucency at the tip of the femoral peg was significantly associated with loosening of the femoral component. Fluoroscopically guided radiographs may improve the zonal reliability of the assessment of RLLs, but further independent and comparative studies are required. In the meantime, the innocence of the physiological RLLs detected by standard radiographs should be viewed with caution. S. Kalra, MA, MBChB, FRCS(Tr&Orth), Specialist Registrar B. Berko, MBChB, Research Fellow N. P. Walton, FRCS(Tr&Orth), Consultant Orthopaedic Surgeon Norfolk and Norwich University Hospital, Colney Lane, Norwich NR4 7UY, UK. T. O. Smith, MSc, BSc(Hons), MCSP, University Lecturer Faculty of Medicine and Health Sciences University of East Anglia, Norwich NR4 7TJ, UK. Correspondence should be sent to Mr S. Kalra; sanjaykalra20@gmail.com 2011 British Editorial Society of Bone and Joint Surgery doi: / x.93b $2.00 J Bone Joint Surg [Br] 2011;93-B: Received 14 October 2010; Accepted after revision 4 February 2011 The Oxford medial phase-3 unicompartmental knee replacement (UKR; Biomet, Swindon, United Kingdom) comprises a keeled tibial tray with a flat upper surface and a pegged spherical femoral component. It uses an unconstrained mobile bearing which is congruent with the femoral component throughout the range of movement. Both tibial and femoral components are cemented. The implant has been advocated for use in painful isolated anteromedial osteoarthritis 1 with an intact anterior cruciate ligament and correctable varus deformity (< 15 ). 2 The Oxford group have recently reported good results at a mean of 5.6 years for 1000 UKRs. 3 Peri-prosthetic radiolucent lines (RLLs) after joint replacement surgery are usually considered to be indicative or predictive of loosening of the component. The presence of RLLs associated with the Oxford medial UKR is well documented, but their aetiology and significance are poorly understood. In 1984, Tibrewal, Grant and Goodfellow 4 reported an incidence of tibial radiolucency of 96% in 80 phase-1 UKRs at one year. In 2006, Pandit et al 5 described an incidence of 70% in 688 phase-3 UKRs at five years. Despite these radiological abnormalities, other series have shown a good survival and clinical outcome at ten and 20 years Goodfellow et al 2 subdivided tibial RLLs into two subtypes: physiological and pathological. Physiological RLLs were classified as those < 2 mm thick, well defined, with an accompanying parallel radiodense line. By contrast, pathological RLLs were > 2 mm thick, poorly defined, and not accompanied by radiodensity. Gulati et al 12 reported an incidence of 62% of physiological RLLs around the tibial component and concluded that the presence of these lines was neither related to symptoms nor indicative or predictive of loosening. We are unaware of any previous studies which have investigated RLLs around the femoral component. The incidence, distribution and significance of these remain unknown. Recently, a much lower incidence of RLLs has been reported with the cementless Oxford medial UKR, 13 which is thought to represent VOL. 93-B, No. 6, JUNE

2 778 S. KALRA, T. O. SMITH, B. BERKO, N. P. WALTON bone incorporation within the prosthesis. While several hypotheses have been proposed to explain the RLLs observed with the cemented prosthesis, 4 the favoured theory is formation of a layer of fibrocartilage as a result of the compressive loading which occurs under the tibial plateau. 14 The importance of fluoroscopically guided radiographs in the assessment of the tibial component has been emphasised in numerous studies, 4,12,15 but their accuracy and validity, both alone and in comparison with standard radiographs, has never been formally investigated. No independent group has yet investigated the radiological assessment of the Oxford UKR. Consequently, it is unclear whether the use of fluoroscopically guided radiographs is common practice and their general adoption for the assessment of tibial RLLs in UKR is debatable. Fluoroscopically guided radiographs are not recommended for assessment of the femoral component. Our aim therefore was to evaluate two issues related to the radiological assessment of UKR. We wished firstly to determine how common is the use of fluoroscopically guided radiographs in joint replacement centres for assessing UKR and secondly, to evaluate the reliability, sensitivity and specificity of tibial and femoral RLLs using standard radiographs. Table I. Reasons for revision surgery in the 92 revisions of 949 Oxford phase-3 procedures. Only those 45 with loosening of a component were included into our revision series Reason Femoral loosening 35 Tibial loosening 10 Bearing dislocation 14 Unexplained pain 10 Progression of lateral disease 10 Fracture 8 Infection 5 Total 92 Number of cases Patients and Methods National survey. We carried out a telephone survey of all acute hospital trusts in the NHS which have an orthopaedic department, in order to determine how often they use fluoroscopically guided radiographs. The NHS website was accessed to identify all 110 eligible hospitals. Each hospital s Superintendent Radiographer (or equivalent) was contacted through the hospital switchboard and was asked about local protocols for the post-operative radiological assessment of patients with UKR. In addition, they were directly questioned about the use of fluoroscopically guided radiographs in this group of patients. Radiological assessment. Our study was carried out in a University Teaching Hospital with a prospective database which included over 1200 operations performed over the last 12 years using the Oxford UKRs, mostly by a single surgeon. Since 2000, 949 phase-3 UKRs had been logged. For each, the database included the clinical outcome score, range of movement and complications. The incidence of revision surgery was also recorded including the intra-operative findings in each case. In total, 92 patients (9.7%) required revision surgery. Table I summarises the reasons for revision. In our study, our revision series included only those 45 cases in which loosening of either the tibial or femoral component had been confirmed intra-operatively. We identified 90 patients who had an Oxford phase-3 UKR performed between January 1, 2000 and December 1, Of these, 45 had required revision because of suspected loosening which had subsequently been confirmed at revision and in whom details of the loose component were recorded (Table I). As Table II shows, these patients were approximately matched by age, gender and knee with 45 patients who had a UKR performed with an uncomplicated follow-up and who did not require revision. The clinical details of both groups are presented in Table II. There were 43 men and 47 women with a mean age of 69.5 years (51 to 91) at the time of radiological examination. In the revision series, ten patients had revision for loosening of the tibial component and 35 for loosening of the femoral component as determined intraoperatively. The radiographs of the revision group were the last taken before revision, at a mean follow-up of 26.8 months (3 to 90). Those of the non-revision group were approximately matched for period of follow-up (26.2 months (1 to 71)). All radiographs were reviewed by two assessors (SK, BB) who were blinded as to whether the patient had or had not undergone revision for loosening after the radiographs were taken. By this means it was possible to assess the sensitivity and specificity of each RLL measurement without assessor bias affecting the results. Both assessors had read the previous literature regarding RLL subtypes and the assessment of tibial RLLs. 12 Both the tibial and femoral components were assessed for each patient by each assessor. One assessor (SK) then repeated his review of both the tibial and femoral implants after a period of three months. All the radiographs were reviewed on the institute s Picture Archiving and Communication System and digitally measured. Tibial RLLs were assessed using the same zonal method described previously by Gulati et al 12 (Fig. 1a). On anteroposterior (AP) view, the tibial component was divided into six zones. Each zone was assessed for the presence of RLLs and the subtype recorded. For femoral RLLs, we developed a system of dividing the lateral cross-table view of the femoral component into six zones (Fig. 1b). Each zone was assessed for the presence of RLLs and the subtype recorded. THE JOURNAL OF BONE AND JOINT SURGERY

3 ASSESSMENT OF RADIOLUCENT LINES AROUND THE OXFORD UNICOMPARTMENTAL KNEE REPLACEMENT 779 Fig. 1a Fig. 1b The zonal assessment for radiolucent lines. Figure 1a anteroposterior radiograph showing the six zones of the tibial component originally described by Gulati et al. 12 Figure 1b lateral cross-table radiograph showing the six zones of the femoral component. Table II. Details of the 90 patients included in our series Revision (n = 45) Non-revision (n = 45) Total (n = 90) Male (%) 23 (51.1) 20 (44.4) 43 (47.8) Female (%) 22 (48.9) 25 (55.6) 47 (52.2) Mean age (range) at radiography in years 69.6 (52 to 91) 69.3 (51 to 84) 69.5 (51 to 91) Side (%) Left 18 (40.0) 18 (40.0) 36 (40.0) Right 27 (60.0) 27 (60.0) 54 (60.0) Frequency of intra-operative tibial loosening (%) 10 (22.2) 10 (11.1) Frequency of intra-operative femoral loosening (%) 35 (77.8) 35 (38.9) The non-revision series had a mean Oxford knee score 16 of 30 (19 to 47) and a mean SF score of 38 (18 to 60) at the time of the radiological examination. Statistical analysis. The clinical details including gender, side of implant, age at radiological examination, and frequency of tibial or femoral loosening were assessed using descriptive statistics consisting of mean, range values and frequences reported as percentages. An assessment of the difference in the frequency of occurrence of physiological and pathological RLLs was compared between the revision and non-revision series at each RLL zone using Fisher s exact test, and for all zones using the chi-squared test. This was carried out for both tibial and femoral implants in both the revision and nonrevision series. A p-value < 0.05 was considered to be statistically significant The sensitivity and specificity of the femoral and tibial RLL assessments were also made as described by Bland. 18 Interobserver reliability was assessed by comparing the femoral and tibial RLL assessments between the two assessors and intra-observer reliability by the assessments of one assessor on two separate occasions. These were calculated using a weighted kappa analysis, 19 and interpreted using the agreement recommendations of Landis and Koch. 20 Results National survey. Of the 110 eligible hospitals, 109 were contacted. The Nuffield Orthopaedic Centre, Oxford, was not contacted since it had previously reported the fact that it used fluoroscopically guided radiographs. 12 The senior radiographer from each of the remaining 109 stated that the hospital used standard weight-bearing AP and crosstable lateral radiographs in the follow-up of UKR. None reported the use of fluoroscopic guidance. Radiological assessment Comparison of tibial radiolucency. There was a greater frequency of pathological tibial lucency in the non-revision compared with the revision group (Table III). However, this was not statistically significant either overall (p =0.37) or when individual zones were compared (between p = 0.62 and p = 0.79 for the six zones, Fisher s exact test). There was a higher incidence of tibial physiological lucency in the revision compared with the non-revision VOL. 93-B, No. 6, JUNE 2011

4 780 S. KALRA, T. O. SMITH, B. BERKO, N. P. WALTON Table III. Radiological assessment of pathological tibial lucency Total Table IV. Radiological assessment of physiological tibial lucency Total Table V. Radiological assessment of pathological femoral lucency Total Table VI. Radiological assessment of physiological femoral lucency Total group (Table IV). However, there was no significant difference in the frequency of physiological lucency between the revision and non-revision groups either overall (p = 0.52) or in individual zones (p = 0.54 to p = 0.98, Fisher s exact test). Comparison of femoral radiolucency. There was a greater frequency of pathological lucency in the revision compared with the non-revision group for each femoral zone (Table V). Statistical analysis showed that this trend was not significant between the revision and non-revision series either overall (p = 0.69) or for individual zones (p = 0.10 to p = 0.65, Fisher s exact test). Table VI shows that while there was a greater number of physiological femoral RLLs in the revised compared with non-revised patients, this difference was not significantly different for zones 1, 2, 4, 5 and 6 (p = 0.08 to p = 0.90, Fisher s exact test). However, there was a statistically significant difference between the groups in detecting RLLs in femoral zone 3 (p = 0.03, Fisher s exact test) as well as an overall difference between the revision and non-revision groups (p = 0.01, chi-squared test). Diagnostic accuracy. The sensitivity and specificity of the tibial RLLs for detecting loosening of the component were 63.6% and 94.4%, respectively. The femoral RLLs were 63.9% sensitive and 72.7% specific. The results of the interobserver reliability indicated that the assessment of tibial pathological loosening ranged from fair to substantial agreement between the two reviewers. However, the interobserver reliability was, at best, moderate for femoral pathological RLLs indicating that this method of assessing RLLs may vary between assessors. Similarly, the assessment of intra-observer reliability indicated poor to good agreement between radiological assessments for both tibial and femoral components suggesting a lack of consistency between the first and second time that they were studied by the same assessor. Discussion Our findings indicate that while the sensitivity and specificity of RLLs using standard radiographs appear to be acceptable, their intra- and interobserver reliability is poor. Although the Oxford group have suggested that RLLs should be assessed using fluoroscopically guided radiographs, 12 the national survey conducted in our study has indicated that this is not routine practice in the United Kingdom. Instead, standard non-fluoroscopically guided radiographs are generally obtained. Our findings agreed with those of previous studies reporting a high incidence of RLLs around the tibial component of the Oxford UKR. 4,5,12 We have also shown a high incidence of RLLs around the femoral component. The aetiology of these is unknown and their reported lack of significance in predicting or indicating loosening of the components remains unexplained. 4,12 We acknowledge that our small sample size may have been insufficient to detect a statistically significant radiological difference between those components which were found to be loose at revision and those which were not, except in femoral zone 3 (at the tip of the peg of the femoral component). However, physiological RLLs were present in greater numbers in the revision group, thereby bringing their lack of significance into question, as suggested by Gulati et al. 12 Conversely, pathological RLLs were also present in large numbers in the non-revision THE JOURNAL OF BONE AND JOINT SURGERY

5 ASSESSMENT OF RADIOLUCENT LINES AROUND THE OXFORD UNICOMPARTMENTAL KNEE REPLACEMENT 781 group, although the difference in incidence was not statistically significant (p = 0.05). The difference shown in femoral zone 3 may be a representation of the pistoning phenomenon which has been described in a knee with a loose femoral component during flexion and extension of the knee. 21 Lucency in this area may represent a genuinely loose component according to our results. Therefore we recommend that particular attention should be paid to femoral zone 3 when reviewing radiographs. Our results suggest that it is difficult to distinguish between physiological and pathological RLLs around both tibial and femoral components using standard radiographs. With respect to the tibial component, this may be because their characteristic features are obscured by a non-parallel x-ray beam, thereby causing RLLs to be missed unless fluoroscopic control is used, as suggested by the Oxford group. 12 By contrast, the geometry of the femoral component may prevent the acquisition of a good view of the interface even if the x-ray beam is parallel. The Oxford group have reported an inter- and intra-observer correlation of more than 0.98 for physiological tibial RLLs when using fluoroscopically guided radiographs. 12 It therefore follows that fluoroscopically guided radiographs may improve the agreement between assessors and therefore make it easier to distinguish between pathological and physiological RLLs, increasing the reliability of diagnosis and the monitoring of progression of loosening. When standard radiographs are used, which is standard procedure in most hospitals, a RLL around the femoral peg is likely to represent loosening of the femoral component. Further studies are required to evaluate the role of fluoroscopically guided radiographs in distinguishing between physiological and pathological RLLs, as are comparative studies to show a clear improvement in the assessment of UKR between fluoroscopically guided and standard radiographs. Listen live Listen to the abstract of this article at Supplementary material A table detailing the intra- and interobserver reliability of the assessment of radiological pathological loosening of each zone of the femoral and tibial components is available with the electronic version of this article on our website at The authors would like to thank Mr M. Glasgow, as the surgeon who performed most of the operations. No benefits in any form have been received or will be received from a commercial party related directly or indirectly to the subject of this article. References 1. White SH, Ludkowski PF, Goodfellow JW. Anteromedial osteoarthritis of the knee. J Bone Joint Surg [Br] 1991;73-B: Goodfellow JW, O Connor JJ, Dodd CA, Murray DW. Unicompartmental arthroplasty with the Oxford knee. Oxford: Oxford University Press, 2006: Pandit H, Jenkins C, Gill HS, et al. Minimally invasive Oxford phase 3 unicompartmental knee replacement: results of 1000 cases. J Bone Joint Surg [Br] 2011;93- B: Tibrewal SB, Grant KA, Goodfellow JW. The radiolucent line beneath the tibial components of the Oxford meniscal knee. J Bone Joint Surg [Br] 1984;66-B: Pandit H, Jenkins C, Barker K, Dodd CA, Murray DW. The Oxford medial unicompartmental knee replacement using a minimally-invasive approach. J Bone Joint Surg [Br] 2006;88-B: Murray DW, Goodfellow JW, O Connor JJ. The Oxford medial unicompartmental arthroplasty: a ten-year survival study. J Bone Joint Surg [Br] 1998;80-B: Svärd UC, Price AJ. Oxford medial unicompartmental knee arthroplasty: a survival analysis of an independent series. J Bone Joint Surg [Br] 2001;83-B: Price AJ, Short A, Kellett C, et al. Ten-year in vivo wear measurement of a fully congruent mobile bearing unicompartmental knee arthroplasty. J Bone Joint Surg [Br] 2005;87-B: Emerson RH Jr, Higgins LL. Unicompartmental knee arthroplasty with the Oxford prosthesis in patients with medial compartment arthritis. J Bone Joint Surg [Am] 2008;90-A: Price AJ, Dodd CA, Svärd UG, Murray DW. Oxford medial unicompartmental knee arthroplasty in patients younger and older than 60 years of age. J Bone Joint Surg [Br] 2005;87-B: Price AJ, Waite JC, Svard U. Long-term clinical results of the medial Oxford unicompartmental knee arthroplasty. Clin Orthop 2005;435: Gulati A, Chau R, Pandit HG, et al. The incidence of physiological radiolucency following Oxford unicompartmental knee replacement and its relationship to outcome. J Bone Joint Surg [Br] 2009;91-B: Pandit H, Jenkins C, Beard DJ, et al. Cementless Oxford unicompartmental knee replacement shows reduced radiolucency at one year. J Bone Joint Surg [Br] 2009;91- B: Simpson DJ, Price AJ, Gulati A, Murray DW, Gill HS. Elevated proximal tibial strains following unicompartmental knee replacement: a possible cause of pain. Med Eng Phys 2009;31: Mukherjee K, Pandit H, Dodd CA, Ostlere S, Murray DW. The Oxford unicompartmental knee arthroplasty: a radiological perspective. Clin Radiol 2008;63: Dawson J, Fitzpatrick R, Murray D, Carr A. Questionnaire on the perceptions of patients about total knee replacement. J Bone Joint Surg [Br] 1988;80-B: Ware J Jr, Kosinski M, Keller SD. A 12-item short-form health survey: construction of scales and preliminary tests of reliability and validity. Med Care 1996;34: Bland M. An introduction to medical statistics. Third ed. London: Oxford University Press, 2006: Altman DG. Practical statistics for medical research. London: Chapman & Hall, 1991: Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics 1977;33: Monk AP, Keys GW, Murray DW. Loosening of the femoral component after unicompartmental knee replacement. J Bone Joint Surg [Br] 2009;91-B: VOL. 93-B, No. 6, JUNE 2011

Cementless Oxford unicompartmental knee replacement shows reduced radiolucency at one year

Cementless Oxford unicompartmental knee replacement shows reduced radiolucency at one year Cementless Oxford unicompartmental knee replacement shows reduced radiolucency at one year H. Pandit, C. Jenkins, D. J. Beard, J. Gallagher, A. J. Price, C. A. F. Dodd, J. W. Goodfellow, D. W. Murray From

More information

Pre-operative clinical and radiological

Pre-operative clinical and radiological Pre-operative clinical and radiological assessment of the patellofemoral joint in unicompartmental knee replacement and its influence on outcome D. J. Beard, H. Pandit, S. Ostlere, C. Jenkins, C. A. F.

More information

Alignment of the femoral component in a mobile-bearing unicompartmental knee arthroplasty Kort, N. P.; van Raay, J. J. A. M.; Thomassen, B. J. W.

Alignment of the femoral component in a mobile-bearing unicompartmental knee arthroplasty Kort, N. P.; van Raay, J. J. A. M.; Thomassen, B. J. W. University of Groningen Alignment of the femoral component in a mobile-bearing unicompartmental knee arthroplasty Kort, N. P.; van Raay, J. J. A. M.; Thomassen, B. J. W. Published in: Knee DOI: 10.1016/j.knee.2007.04.007

More information

With over 40 years clinical experience, the Oxford Partial Knee is the most widely used, 1 clinically proven 2 partial knee system in the world.

With over 40 years clinical experience, the Oxford Partial Knee is the most widely used, 1 clinically proven 2 partial knee system in the world. Oxford Partial Knee A Definitive Implant With over 40 years clinical experience, the Oxford Partial Knee is the most widely used, 1 clinically proven 2 partial knee system in the world. Compared with total

More information

The Knee. The Twin Peg Oxford partial knee replacement: The first 100 cases. Stephen H. White a,, Sharon Roberts a, Peter W.

The Knee. The Twin Peg Oxford partial knee replacement: The first 100 cases. Stephen H. White a,, Sharon Roberts a, Peter W. The Knee 19 (2012) 36 40 Contents lists available at ScienceDirect The Knee The Twin Peg Oxford partial knee replacement: The first 100 cases Stephen H. White a,, Sharon Roberts a, Peter W. Jones b a Department

More information

The effect of leg alignment on the outcome of unicompartmental knee replacement

The effect of leg alignment on the outcome of unicompartmental knee replacement The effect of leg alignment on the outcome of unicompartmental knee replacement A. Gulati, H. Pandit, C. Jenkins, R. Chau, C. A. F. Dodd, D. W. Murray From Nuffield Orthopaedic Centre, Oxford, England

More information

Ten-year in vivo wear measurement of a fully congruent mobile bearing unicompartmental knee arthroplasty

Ten-year in vivo wear measurement of a fully congruent mobile bearing unicompartmental knee arthroplasty Ten-year in vivo wear measurement of a fully congruent mobile bearing unicompartmental knee arthroplasty A. J. Price, A. Short, C. Kellett, D. Beard, H. Gill, H. Pandit, C. A. F. Dodd, D. W. Murray From

More information

Oxford. Partial Knee

Oxford. Partial Knee Oxford Partial Knee Oxford Partial Knee A Definitive Implant The Oxford Partial Knee is the most widely used 38 and clinically proven 22 partial knee replacement (PKR) system in the world, offering industry

More information

The Oxford phase III unicompartmental knee replacement in patients less than 60 years of age Kort, Nanne P.; van Raay, Jos J. A. M.; van Horn, Jim J.

The Oxford phase III unicompartmental knee replacement in patients less than 60 years of age Kort, Nanne P.; van Raay, Jos J. A. M.; van Horn, Jim J. University of Groningen The Oxford phase III unicompartmental knee replacement in patients less than 60 years of age Kort, Nanne P.; van Raay, Jos J. A. M.; van Horn, Jim J. Published in: Knee surgery

More information

Gender Solutions Patello-Femoral Joint System

Gender Solutions Patello-Femoral Joint System Zimmer Biomet is the leading company in partial knee arthroplasty (PKA) 1 with over 40 years experience, offering a comprehensive range of anatomic and innovative solutions. Research shows that surgeons

More information

)301( COPYRIGHT 2018 BY THE ARCHIVES OF BONE AND JOINT SURGERY

)301( COPYRIGHT 2018 BY THE ARCHIVES OF BONE AND JOINT SURGERY )301( COPYRIGHT 2018 BY THE ARCHIVES OF BONE AND JOINT SURGERY RESEARCH ARTICLE Early Results of Oxford Mobile Bearing Medial Unicompartmental Knee Replacement (UKR) with the Microplasty Instrumentation:

More information

Minimally invasive unicompartmental knee arthroplasty in treatment of osteonecrosis versus osteoarthritis : a matched-pair comparison

Minimally invasive unicompartmental knee arthroplasty in treatment of osteonecrosis versus osteoarthritis : a matched-pair comparison Acta Orthop. Belg., 2015, 81, 333-339 ORIGINAL STUDY Minimally invasive unicompartmental knee arthroplasty in treatment of osteonecrosis versus osteoarthritis : a matched-pair comparison Qidong Zhang,

More information

The influence of degeneration of the lateral patellofemoral joint on outcome of medial unicompartmental knee replacement

The influence of degeneration of the lateral patellofemoral joint on outcome of medial unicompartmental knee replacement 2015 4 ORTHOPAEDIC BIOMECHANICS MATERIALS AND CLINICAL STUDY.29. doi: 10.3969/j.issn. 1672-5972.2015.02.008 swgk2015-03-0050 * 1 1 2 1 * 1 1 [ ] Oxford 2009 8 2013 12 126 (104 ) Ahlback Weidow 5 1 Hospital

More information

SEVERE VARUS AND VALGUS DEFORMITIES TREATED BY TOTAL KNEE ARTHROPLASTY

SEVERE VARUS AND VALGUS DEFORMITIES TREATED BY TOTAL KNEE ARTHROPLASTY SEVERE VARUS AND VALGUS DEFORMITIES TREATED BY TOTAL KNEE ARTHROPLASTY Th. KARACHALIOS, P. P. SARANGI, J. H. NEWMAN From Winford Orthopaedic Hospital, Bristol, England We report a prospective case-controlled

More information

Case Report Meniscal Bearing Dislocation of Unicompartmental Knee Arthroplasty with Faint Symptom

Case Report Meniscal Bearing Dislocation of Unicompartmental Knee Arthroplasty with Faint Symptom Case Reports in Orthopedics Volume 2015, Article ID 217842, 5 pages http://dx.doi.org/10.1155/2015/217842 Case Report Meniscal Bearing Dislocation of Unicompartmental Knee Arthroplasty with Faint Symptom

More information

Polyethylene wear of mobile-bearing unicompartmental knee replacement at 20 years

Polyethylene wear of mobile-bearing unicompartmental knee replacement at 20 years KNEE Polyethylene wear of mobile-bearing unicompartmental knee replacement at 20 years B. J. L. Kendrick, D. J. Simpson, B. L. Kaptein, E. R. Valstar, H. S. Gill, D. W. Murray, A. J. Price From the Nuffield

More information

Functional Outcome of Uni-Knee Arthroplasty in Asians with six-year Follow-up

Functional Outcome of Uni-Knee Arthroplasty in Asians with six-year Follow-up Functional Outcome of Uni-Knee Arthroplasty in Asians with six-year Follow-up Ching-Jen Wang, M.D. Department of Orthopedic Surgery Kaohsiung Chang Gung Memorial Hospital Chang Gung University College

More information

Implant Overhang after Unicompartmental Knee Arthroplasty: Oxford Prosthesis versus Miller-Galante II Prosthesis

Implant Overhang after Unicompartmental Knee Arthroplasty: Oxford Prosthesis versus Miller-Galante II Prosthesis Original Article Knee Surg Relat Res 2014;26(2):82-87 http://dx.doi.org/10.5792/ksrr.2014.26.2.82 pissn 2234-0726 eissn 2234-2451 Knee Surgery & Related Research Implant Overhang after Unicompartmental

More information

Revision surgery for failed unicompartmental knee replacement : Technical aspects and clinical outcome

Revision surgery for failed unicompartmental knee replacement : Technical aspects and clinical outcome Acta Orthop. Belg., 2013, 79, 312-317 ORIGINAL STUDY Revision surgery for failed unicompartmental knee replacement : Technical aspects and clinical outcome Curtis A. Robb, Gulraj S. Matharu, Khalid Baloch,

More information

1. White SH, Nazarian NA, McEwen Smith AM, Balfour TW. Periampullary adenoma causing pancreatitis. Br Med J 1981; 283:527.

1. White SH, Nazarian NA, McEwen Smith AM, Balfour TW. Periampullary adenoma causing pancreatitis. Br Med J 1981; 283:527. Mr Steve White, Consultant Orthopaedic Surgeon Peer-reviewed original papers: 1. White SH, Nazarian NA, McEwen Smith AM, Balfour TW. Periampullary adenoma causing pancreatitis. Br Med J 1981; 283:527.

More information

Bilateral total knee arthroplasty: One mobile-bearing and one fixed-bearing

Bilateral total knee arthroplasty: One mobile-bearing and one fixed-bearing Journal of Orthopaedic Surgery 2001, 9(1): 45 50 Bilateral total knee arthroplasty: One mobile-bearing and one fixed-bearing KY Chiu, TP Ng, WM Tang and P Lam Department of Orthopaedic Surgery, The University

More information

Ten- to 15-year results of the Oxford Phase III mobile unicompartmental knee arthroplasty

Ten- to 15-year results of the Oxford Phase III mobile unicompartmental knee arthroplasty L. A. Lisowski, L. I. Meijer, M. P. J. van den Bekerom, P. Pilot, A. E. Lisowski From BovenIJ Hospital, Statenjachtstraat 1, 1034 CS Amsterdam, The Netherlands L. A. Lisowski, MD, PhD, Orthopaedic Surgeon,

More information

Unicompartmental or total knee replacement

Unicompartmental or total knee replacement Unicompartmental or total knee replacement THE 15-YEAR RESULTS OF A PROSPECTIVE RANDOMISED CONTROLLED TRIAL J. Newman, R. V. Pydisetty, C. Ackroyd From Avon Orthopaedic Centre, Bristol, England Between

More information

Mid-Term Results of Oxford Medial Unicompartmental Knee Arthroplasty

Mid-Term Results of Oxford Medial Unicompartmental Knee Arthroplasty Original Article Clinics in Orthopedic Surgery 2011;3:178-183 http://dx.doi.org/10.4055/cios.2011.3.3.178 Mid-Term Results of Oxford Medial Unicompartmental Knee Arthroplasty Won-Sik Choy, MD, Kap Jung

More information

Medium-term outcome of cementless, mobile-bearing, unicompartmental knee arthroplasty

Medium-term outcome of cementless, mobile-bearing, unicompartmental knee arthroplasty Original Article Page 1 of 12 Medium-term outcome of cementless, mobile-bearing, unicompartmental knee arthroplasty Radosław Stempin 1, Kacper Stempin 2, Wiesław Kaczmarek 3 1 Department of Orthopedic

More information

The young patient and the medial unicompartmental knee replacement

The young patient and the medial unicompartmental knee replacement Acta Orthop. Belg., 2015, 81, 283-288 ORIGINAL STUDY The young patient and the medial unicompartmental knee replacement Omar Faour Martín, Jose Antonio Valverde García, Miguel Ángel Martín Ferrero, Aurelio

More information

Fixed or Mobile bearing in Unicompartmental Knee Arthroplasty

Fixed or Mobile bearing in Unicompartmental Knee Arthroplasty Fixed or Mobile bearing in Unicompartmental Knee Arthroplasty Jean-Noel Argenson, Matthieu Ollivier, Xavier Flecher, Sebastien Parratte Institute for Locomotion Sainte Marguerite Hospital, Marseille, France

More information

Oxford Phase 3 unicompartmental knee arthroplasty: medium-term results of a minimally invasive surgical procedure

Oxford Phase 3 unicompartmental knee arthroplasty: medium-term results of a minimally invasive surgical procedure Knee Surg Sports Traumatol Arthrosc (2011) 19:277 284 DOI 10.1007/s00167-010-1213-2 KNEE Oxford Phase 3 unicompartmental knee arthroplasty: medium-term results of a minimally invasive surgical procedure

More information

Oxford phase 3 unicompartmental knee replacement in Korean patients

Oxford phase 3 unicompartmental knee replacement in Korean patients KNEE Oxford phase 3 unicompartmental knee replacement in Korean patients H-C. Lim, J-H. Bae, S-H. Song, S-J. Kim From Guro Hospital, Korea University Medical Center, Seoul, Korea Medium-term survivorship

More information

Unicondylar Knee Vs Total Knee Replacement: Is Less Better In the Middle Aged Athlete

Unicondylar Knee Vs Total Knee Replacement: Is Less Better In the Middle Aged Athlete Unicondylar Knee Vs Total Knee Replacement: Is Less Better In the Middle Aged Athlete Chair: Maurilio Marcacci, MD Alois Franz "Basic principles and considerations of the Unis" Joao M. Barretto "Sport

More information

The UniSpacer : correcting varus malalignment in medial gonarthrosis

The UniSpacer : correcting varus malalignment in medial gonarthrosis DOI 10.1007/s00264-009-0908-9 ORIGINAL PAPER The UniSpacer : correcting varus malalignment in medial gonarthrosis Michael Clarius & Justus F. Becker & Holger Schmitt & Joern B. Seeger Received: 20 October

More information

The Survivorship and Clinical Results of Minimally Invasive Unicompartmental Knee Arthroplasty at 10-Year Follow-up

The Survivorship and Clinical Results of Minimally Invasive Unicompartmental Knee Arthroplasty at 10-Year Follow-up Original Article Clinics in Orthopedic Surgery 2015;7:199-206 http://dx.doi.org/10.4055/cios.2015.7.2.199 The Survivorship and Clinical Results of Minimally Invasive Unicompartmental Knee Arthroplasty

More information

Simplifying the Most Clinically Proven 1 Partial Knee in the World. Oxford Partial Knee with Microplasty Instrumentation

Simplifying the Most Clinically Proven 1 Partial Knee in the World. Oxford Partial Knee with Microplasty Instrumentation Simplifying the Most Clinically Proven 1 Partial Knee in the World Oxford Partial Knee with Microplasty Instrumentation 1 Microplasty Instrumentation Innovative, Accurate, Reproducible Microplasty Instrumentation

More information

Early failure of total hip replacements implanted at distant hospitals to reduce waiting lists

Early failure of total hip replacements implanted at distant hospitals to reduce waiting lists : 31 35 doi 10.1308/1478708051450 Audit Early failure of total hip replacements implanted at distant hospitals to reduce waiting lists Jac Ciampolini, Matthew JW Hubble Princess Elizabeth Orthopaedic Centre,

More information

Medial unicompartmental knee replacement in the under-50s

Medial unicompartmental knee replacement in the under-50s Medial unicompartmental knee replacement in the under-50s S. Parratte, J.-N.A.Argenson, O. Pearce, V. Pauly, P. Auquier, J.-M. Aubaniac From Aix-Marseille University, Marseille, France We retrospectively

More information

Oxford Partial Knee Manual of the Surgical Technique

Oxford Partial Knee Manual of the Surgical Technique Oxford Partial Knee Manual of the Surgical Technique Disclaimer The Surgical Technique herein is presented to demonstrate the technique developed and utilised by Prof. D.W. Murray, Mr. J. Goodfellow, Prof.

More information

Stefan Rahm MD University Hospital Balgrist

Stefan Rahm MD University Hospital Balgrist Knee Prosthesis Models & Materials, Surgical Techniques and Approaches Stefan Rahm MD University Hospital Balgrist INTRODUCTION VARUS VALGUS 46 Y OLD MALE Pain in the medial compartment left more than

More information

EARLY CLINICAL RESULTS OF PRIMARY CEMENTLESS TOTAL KNEE ARTHROPLASTY

EARLY CLINICAL RESULTS OF PRIMARY CEMENTLESS TOTAL KNEE ARTHROPLASTY EARLY CLINICAL RESULTS OF PRIMARY CEMENTLESS TOTAL KNEE ARTHROPLASTY Benkovich V. Perry T., Bunin A., Bilenko V., Unit for Joint Arthroplasty, Soroka Medical Center Ben Gurion University of Negev Beer

More information

Stephen R Smith Northeast Nebraska Orthopaedics PC. Ligament Preserving Techniques in Total Knee Arthroplasty

Stephen R Smith Northeast Nebraska Orthopaedics PC. Ligament Preserving Techniques in Total Knee Arthroplasty Stephen R Smith Northeast Nebraska Orthopaedics PC Ligament Preserving Techniques in Total Knee Arthroplasty 10-15% have Fair to poor Results? Why? The complication rate is 2.567% If It happens To You

More information

Management of Periprosthetic Fracture in Unicompartmental Knee Arthroplasty Patients: A Case Series

Management of Periprosthetic Fracture in Unicompartmental Knee Arthroplasty Patients: A Case Series Management of Periprosthetic Fracture in Unicompartmental Knee Arthroplasty Patients: A Case Series Yew Lok Woo, MBBS, Pak Lin Chin, MBBS, FRCS, Ngai Nung Lo, MBBS, FRCS, Shi-Lu Chia, PhD, Darren Keng

More information

Complications of Medial Unicompartmental Knee Arthroplasty

Complications of Medial Unicompartmental Knee Arthroplasty Original Article Clinics in Orthopedic Surgery 2014;6:365-372 http://dx.doi.org/10.4055/cios.2014.6.4.365 Complications of Medial Unicompartmental Knee Arthroplasty Jong Hun Ji, MD, Sang Eun Park, MD,

More information

Radiological Decision Aid to determine suitability for medial unicompartmental knee arthroplasty

Radiological Decision Aid to determine suitability for medial unicompartmental knee arthroplasty KNEE Radiological Decision Aid to determine suitability for medial unicompartmental knee arthroplasty DEVELOPMENT AND PRELIMINARY VALIDATION T. W. Hamilton, H. G. Pandit, A. V. Lombardi, J. B. Adams, C.

More information

PARTIALS?1 SHOULD BE AT LEAST 20% DID YOU KNOW OF KNEE REPLACEMENTS

PARTIALS?1 SHOULD BE AT LEAST 20% DID YOU KNOW OF KNEE REPLACEMENTS PARTIAL KNEE DID YOU KNOW AT LEAST 20% OF KNEE REPLACEMENTS SHOULD BE PARTIALS?1 Research shows that surgeons utilizing Partial Knee Arthroplasty (PKA) for at least 20% of their annual knee arthroplasties

More information

Conversion of unicompartmental knee arthroplasty to total knee arthroplasty : The challenges and need for augments

Conversion of unicompartmental knee arthroplasty to total knee arthroplasty : The challenges and need for augments Acta Orthop. Belg., 2013, 79, 699-705 ORIGINAL STUDY Conversion of unicompartmental knee arthroplasty to total knee arthroplasty : The challenges and need for augments Zeeshan Khan, Syed Z. Nawaz, Steven

More information

Simplifying the Most Clinically Proven Partial Knee in the World. Oxford Partial Knee with Microplasty Instrumentation

Simplifying the Most Clinically Proven Partial Knee in the World. Oxford Partial Knee with Microplasty Instrumentation Simplifying the Most Clinically Proven Partial Knee in the World Oxford Partial Knee with Microplasty Instrumentation 1 Microplasty Instrumentation Innovative, Accurate, Reproducible Microplasty instrumentation

More information

BIOMECHANICAL MECHANISMS FOR DAMAGE: RETRIEVAL ANALYSIS AND COMPUTATIONAL WEAR PREDICTIONS IN TOTAL KNEE REPLACEMENTS

BIOMECHANICAL MECHANISMS FOR DAMAGE: RETRIEVAL ANALYSIS AND COMPUTATIONAL WEAR PREDICTIONS IN TOTAL KNEE REPLACEMENTS Journal of Mechanics in Medicine and Biology Vol. 5, No. 3 (2005) 469 475 c World Scientific Publishing Company BIOMECHANICAL MECHANISMS FOR DAMAGE: RETRIEVAL ANALYSIS AND COMPUTATIONAL WEAR PREDICTIONS

More information

AFTER TOTAL KNEE REPLACEMENT

AFTER TOTAL KNEE REPLACEMENT CORONAL ALIGNMENT AFTER TOTAL KNEE REPLACEMENT ROBERT S. JEFFERY, RICHARD W. MORRIS, ROBIN A. DENHAM From Queen Alexandra Hospital, Portsmouth Maquet s line passes from the centre of the femoral head to

More information

Periarticular knee osteotomy

Periarticular knee osteotomy Periarticular knee osteotomy Turnberg Building Orthopaedics 0161 206 4803 All Rights Reserved 2018. Document for issue as handout. Knee joint The knee consists of two joints which allow flexion (bending)

More information

Thomas William Hamilton

Thomas William Hamilton Assessment of the Arthritic Knee: Patient Selection for Oxford Unicompartmental Knee Arthroplasty A dissertation submitted to the University of Oxford in partial fulfillment of the requirements for the

More information

Uniglide. Unicompartmental Knee Replacement Mk III surgical technique. The mobile bearing is not commercially available in the USA

Uniglide. Unicompartmental Knee Replacement Mk III surgical technique. The mobile bearing is not commercially available in the USA Uniglide Unicompartmental Knee Replacement Mk III surgical technique The mobile bearing is not commercially available in the USA Uniglide Contents Introduction 4 Compatibility chart 7 Operative summary

More information

No radiographic difference between patient-specific guiding and conventional Oxford UKA surgery

No radiographic difference between patient-specific guiding and conventional Oxford UKA surgery DOI 10.1007/s00167-014-2849-0 KNEE No radiographic difference between patient-specific guiding and conventional Oxford UKA surgery Bart Kerens Martijn G. M. Schotanus Bert Boonen Nanne P. Kort Received:

More information

why bicompartmental? A REVOLUTIONARY ALTERNATIVE TO TOTAL KNEE REPLACEMENTS

why bicompartmental? A REVOLUTIONARY ALTERNATIVE TO TOTAL KNEE REPLACEMENTS why bicompartmental? A REVOLUTIONARY ALTERNATIVE TO TOTAL KNEE REPLACEMENTS TKR is not always the answer Today, many patients with medial or lateral disease and patellofemoral involvement receive a Total

More information

Revolution. Unicompartmental Knee System

Revolution. Unicompartmental Knee System Revolution Unicompartmental Knee System While Total Knee Arthroplasty (TKA) is one of the most predictable procedures in orthopedic surgery, many patients undergoing TKA are in fact excellent candidates

More information

CLINICAL PRESENTATION AND RADIOLOGY QUIZ QUESTION

CLINICAL PRESENTATION AND RADIOLOGY QUIZ QUESTION Donald L. Renfrew, MD Radiology Associates of the Fox Valley, 333 N. Commercial Street, Suite 100, Neenah, WI 54956 11/24/2012 Radiology Quiz of the Week # 100 Page 1 CLINICAL PRESENTATION AND RADIOLOGY

More information

Clinical Study Cemented versus Uncemented Oxford Unicompartmental Knee Arthroplasty: Is There a Difference?

Clinical Study Cemented versus Uncemented Oxford Unicompartmental Knee Arthroplasty: Is There a Difference? Advances in Orthopedics Volume 2013, Article ID 245915, 6 pages http://dx.doi.org/10.1155/2013/245915 Clinical Study Cemented versus Uncemented Oxford Unicompartmental Knee Arthroplasty: Is There a Difference?

More information

Anterior knee pain following total knee replacement caused by isolated Paget's disease of patella

Anterior knee pain following total knee replacement caused by isolated Paget's disease of patella ISPUB.COM The Internet Journal of Orthopedic Surgery Volume 9 Number 2 Anterior knee pain following total knee replacement caused by isolated Paget's disease of patella R Gupta, S Canty, W Ryan Citation

More information

Map 48: Rate of metal-on-metal hip resurfacing procedures undertaken per population by PCT

Map 48: Rate of metal-on-metal hip resurfacing procedures undertaken per population by PCT 162 NHS ATLAS OF VARIATION PROBLEMS OF THE MUSCULO-SKELETAL SYSTEM Map 48: Rate of metal-on-metal hip resurfacing procedures undertaken per population by PCT Directly standardised rate 2009/10 Domain 2:

More information

H.P. Teng, Y.J. Chou, L.C. Lin, and C.Y. Wong Under general or spinal anesthesia, the knee was flexed gently. In the cases of limited ROM, gentle and

H.P. Teng, Y.J. Chou, L.C. Lin, and C.Y. Wong Under general or spinal anesthesia, the knee was flexed gently. In the cases of limited ROM, gentle and THE BENEFIT OF ARTHROSCOPY FOR SYMPTOMATIC TOTAL KNEE ARTHROPLASTY Hsiu-Peng Teng, Yi-Jiun Chou, Li-Chun Lin, and Chi-Yin Wong Department of Orthopedic Surgery, Kaohsiung Veterans General Hospital, Kaohsiung,

More information

A study of functional outcome after Primary Total Knee Arthroplasty in elderly patients

A study of functional outcome after Primary Total Knee Arthroplasty in elderly patients Original Research Article A study of functional outcome after Primary Total Knee Arthroplasty in elderly patients Ragesh Chandran 1*, Sanath K Shetty 2, Ashwin Shetty 3, Bijith Balan 1, Lawrence J Mathias

More information

CLINICAL AND OPERATIVE APPROACH FOR TOTAL KNEE REPLACEMENT DR.VINMAIE ORTHOPAEDICS PG 2 ND YEAR

CLINICAL AND OPERATIVE APPROACH FOR TOTAL KNEE REPLACEMENT DR.VINMAIE ORTHOPAEDICS PG 2 ND YEAR CLINICAL AND OPERATIVE APPROACH FOR TOTAL KNEE REPLACEMENT DR.VINMAIE ORTHOPAEDICS PG 2 ND YEAR Evolution of TKR In 1860, Verneuil proposed interposition arthroplasty, involving the insertion of soft tissue

More information

Mr Aslam Mohammed FRCS, FRCS (Orth) Consultant Orthopaedic Surgeon Specialising in Lower Limb Arthroplasty and Sports Injury

Mr Aslam Mohammed FRCS, FRCS (Orth) Consultant Orthopaedic Surgeon Specialising in Lower Limb Arthroplasty and Sports Injury Mr Aslam Mohammed FRCS, FRCS (Orth) Consultant Orthopaedic Surgeon Specialising in Lower Limb Arthroplasty and Sports Injury I qualified from the Welsh National School of Medicine in Cardiff in 1984. I

More information

Original Report. The Reverse Segond Fracture: Association with a Tear of the Posterior Cruciate Ligament and Medial Meniscus

Original Report. The Reverse Segond Fracture: Association with a Tear of the Posterior Cruciate Ligament and Medial Meniscus Eva M. Escobedo 1 William J. Mills 2 John. Hunter 1 Received July 10, 2001; accepted after revision October 1, 2001. 1 Department of Radiology, University of Washington Harborview Medical enter, 325 Ninth

More information

The St. Leger total knee replacement: a false economy Westwood M J, White S P, Bannister G C

The St. Leger total knee replacement: a false economy Westwood M J, White S P, Bannister G C The St. Leger total knee replacement: a false economy Westwood M J, White S P, Bannister G C Record Status This is a critical abstract of an economic evaluation that meets the criteria for inclusion on

More information

For Commercial products, please refer to the following policy: Preauthorization via Web-Based Tool for Procedures

For Commercial products, please refer to the following policy: Preauthorization via Web-Based Tool for Procedures Medical Coverage Policy Total Joint Arthroplasty Hip and Knee EFFECTIVE DATE: 08/01/2017 POLICY LAST UPDATED: 06/06/2017 OVERVIEW Joint replacement surgery, also known as arthroplasty, has proved to be

More information

Fracture risk in unicameral bone cyst. Is magnetic resonance imaging a better predictor than plain radiography?

Fracture risk in unicameral bone cyst. Is magnetic resonance imaging a better predictor than plain radiography? Acta Orthop. Belg., 2011, 77, 230-238 ORIGINAL STUDY Fracture risk in unicameral bone cyst. Is magnetic resonance imaging a better predictor than plain radiography? Nathalie PiREAU, Antoine DE GHELDERE,

More information

R/F. Can T-smart Tomosynthesis Improve Diagnostic Accuracy on THA Component Stability? 1. Abstract

R/F. Can T-smart Tomosynthesis Improve Diagnostic Accuracy on THA Component Stability? 1. Abstract R/F Can T-smart Tomosynthesis Improve Diagnostic Accuracy on THA Component Stability? Professor and Chair Dept. of Adult Reconstructive Surgery Beijing Jishuitan Hospital, the 4th Clinical College of PKU

More information

Knee arthroplasty: What radiologists should know.

Knee arthroplasty: What radiologists should know. Knee arthroplasty: What radiologists should know. Poster No.: C-2174 Congress: ECR 2014 Type: Educational Exhibit Authors: J. Araújo 1, J. Pires 2, J. Oliveira 3, C. Macedo 1, S. Magalhães 1, I. Ferreira

More information

TOTAL KNEE ARTHROPLASTY (TKA)

TOTAL KNEE ARTHROPLASTY (TKA) TOTAL KNEE ARTHROPLASTY (TKA) 1 Anatomy, Biomechanics, and Design 2 Femur Medial and lateral condyles Convex, asymmetric Medial larger than lateral 3 Tibia Tibial plateau Medial tibial condyle: concave

More information

DePuy Attune CR and Attune PS

DePuy Attune CR and Attune PS Implant Summary Report for: DePuy Comprising PRIMARY knees implanted up to: 06 February 2017 NJR Database extract: 07 April 2017 Produced on: Licensed for use until: 19 April 2017 19 April 2018 Contents

More information

Outcome of Girdlestone s resection arthroplasty following complications of proximal femoral fractures

Outcome of Girdlestone s resection arthroplasty following complications of proximal femoral fractures Acta Orthop. Belg., 2006, 72, 555-559 ORIGINAL STUDY Outcome of Girdlestone s resection arthroplasty following complications of proximal femoral fractures Himanshu SHARMA, Rahul KAKAR From the Royal Alexandra

More information

CONTRIBUTING SURGEON. Barry Waldman, MD Director, Center for Joint Preservation and Replacement Sinai Hospital of Baltimore Baltimore, MD

CONTRIBUTING SURGEON. Barry Waldman, MD Director, Center for Joint Preservation and Replacement Sinai Hospital of Baltimore Baltimore, MD CONTRIBUTING SURGEON Barry Waldman, MD Director, Center for Joint Preservation and Replacement Sinai Hospital of Baltimore Baltimore, MD System Overview The EPIK Uni is designed to ease the use of the

More information

Field testing the Unified Classification System for periprosthetic fractures of the femur, tibia and patella in association with knee replacement

Field testing the Unified Classification System for periprosthetic fractures of the femur, tibia and patella in association with knee replacement J. M. Van der Merwe, F. S. Haddad, C. P. Duncan From University of British Columbia, Vancouver, British Columbia, Canada J. M. Van der Merwe, MBChB, FRCSC, Clinical Assistant Professor University of Saskatchewan,

More information

Bicruciate-Retaining or Medial Pivot Total Knee Prosthesis Pritchett 225 Fig. 3. The MP total knee prosthesis. Fig. 1. An anteroposterior radiograph o

Bicruciate-Retaining or Medial Pivot Total Knee Prosthesis Pritchett 225 Fig. 3. The MP total knee prosthesis. Fig. 1. An anteroposterior radiograph o The Journal of Arthroplasty Vol. 26 No. 2 2011 Patients Prefer A Bicruciate-Retaining or the Medial Pivot Total Knee Prosthesis James W. Pritchett, MD, FACS Abstract: Four-hundred forty patients underwent

More information

Produced on: Licenced for use until: Corail Stem (Standard Offset Collared)

Produced on: Licenced for use until: Corail Stem (Standard Offset Collared) Implant Bespoke Report for: DePuy Comprising PRIMARY hips implanted up to: 09 October 2017 NJR Database extract: 08 December 2017 Produced on: Licenced for use until: 29 December 2017 29 April 2018 Contents

More information

Reprint requests: Dr MA Hassaballa Avon Orthopaedic Centre, Southmead Hospital Westbury-on-Trym Bristol BS10 5NB, UK

Reprint requests: Dr MA Hassaballa Avon Orthopaedic Centre, Southmead Hospital Westbury-on-Trym Bristol BS10 5NB, UK CLINICAL ARTICLE SA ORTHOPAEDIC JOURNAL Spring 2012 Vol 11 No 3 / Page 79 C L I N I C A L A RT I C L E The effect of joint line restoration on kneeling ability after primary total knee replacement MA Hassaballa

More information

Knee Replacement Implants

Knee Replacement Implants Knee Replacement Implants During knee replacement surgery, an orthopaedic surgeon will resurface your damaged knee with artificial components, called implants. There are many different types of implants.

More information

Keywords Osteoarthritis; Knee; Pathology; Biopsy

Keywords Osteoarthritis; Knee; Pathology; Biopsy Carlos Antônio Garrido 1, Tania Clarete Fonseca Vieira Sales Sampaio 2, Frederico de Souza Ferreira 3 Objectives: To compare the modified Ahlbäck radiological classification with macroscopic analysis of

More information

THE KNEE SOCIETY VIRTUAL FELLOWSHIP

THE KNEE SOCIETY VIRTUAL FELLOWSHIP THE KNEE SOCIETY VIRTUAL FELLOWSHIP CHAPTER IX PARTIAL KNEE: MEDIAL, LATERAL AND PFR Revision of Failed Unicompartmental to Total Knee Arthroplasty Presented by: Keith R. Berend, MD COPYRIGHT 2016 THE

More information

Midterm results of cemented Press Fit Condylar Sigma total knee arthroplasty system

Midterm results of cemented Press Fit Condylar Sigma total knee arthroplasty system Journal of Orthopaedic Surgery 2005:13(3):280-284 Midterm results of cemented Press Fit Condylar Sigma total knee arthroplasty system S Asif, DSK Choon Department of Orthopaedic Surgery, University of

More information

Tissue-sparing surgery with the bi-unicompartmental knee prosthesis: retrospective study with minimum follow-up of 36 months

Tissue-sparing surgery with the bi-unicompartmental knee prosthesis: retrospective study with minimum follow-up of 36 months J Orthopaed Traumatol (2006) 7:108 112 DOI 10.1007/s10195-005- - TSS SECTION N. Confalonieri A. Manzotti Tissue-sparing surgery with the bi-unicompartmental knee prosthesis: retrospective study with minimum

More information

What to expect from your NAVIO Robotics-assisted Partial Knee Replacement

What to expect from your NAVIO Robotics-assisted Partial Knee Replacement What to expect from your NAVIO Robotics-assisted Partial Knee Replacement Patient guide The NAVIO Surgical System can help your surgeon get you back in action with accurate and precise partial knee replacement.

More information

Analysis of an Early Intervention Tibial Component for Medial Osteoarthritis

Analysis of an Early Intervention Tibial Component for Medial Osteoarthritis Analysis of an Early Intervention Tibial Component for Medial Osteoarthritis Miriam Chaudhary, M.Sc. 1, Peter S. Walker, PhD 2. 1 NYU Hospital for Joint Diseases, New York City, NY, USA, 2 NYU-Hospital

More information

Raising Transparency of Pricing for Total Hip and Total Knee Replacements: A National Pilot on Value for Money for the NHS in Orthopaedic Procurement

Raising Transparency of Pricing for Total Hip and Total Knee Replacements: A National Pilot on Value for Money for the NHS in Orthopaedic Procurement 11 th June 2015 Dear Colleague Raising Transparency of Pricing for Total Hip and Total Knee Replacements: A National Pilot on Value for Money for the NHS in Orthopaedic Procurement I write on behalf of

More information

Smith & Nephew. R3 Cementless Cup

Smith & Nephew. R3 Cementless Cup Implant Smith & Nephew Comprising PRIMARY hips implanted up to: 09 September 2018 NJR Database extract: 08 November 2018 Produced on: Licenced for use until: 18 November 2018 18 March 2019 Contents Recorded

More information

An older systematic review looked at the evidence behind the best approach to evaluate acute knee pain in primary care (Ann Int Med.2003;139:575).

An older systematic review looked at the evidence behind the best approach to evaluate acute knee pain in primary care (Ann Int Med.2003;139:575). There is so much we don't know in medicine that could make a difference, and often we focus on the big things, and the little things get forgotten. To highlight some smaller but important issues, we've

More information

National Joint Replacement Registry. Lay Summary 2015 Annual Report Hip and Knee Replacement

National Joint Replacement Registry. Lay Summary 2015 Annual Report Hip and Knee Replacement National Joint Replacement Registry Lay Summary 2015 Annual Report Hip and Knee Replacement SUPPLEMENTARY REPORT 2015 TABLE OF CONTENTS Introduction... 1 A brief history of the Registry origins... 1 The

More information

The Unispacer TM unicompartmental knee implant: Its outcomes in medial compartment knee osteoarthritis

The Unispacer TM unicompartmental knee implant: Its outcomes in medial compartment knee osteoarthritis Orthopaedics & Traumatology: Surgery & Research (2011) 97, 410 417 ORIGINAL ARTICLE The Unispacer TM unicompartmental knee implant: Its outcomes in medial compartment knee osteoarthritis C. Catier, M.

More information

Limb alignment in computer-assisted minimally-invasive unicompartmental knee replacement

Limb alignment in computer-assisted minimally-invasive unicompartmental knee replacement Limb alignment in computer-assisted minimally-invasive unicompartmental knee replacement G. Keene, D. Simpson, Y. Kalairajah From Sportsmed-SA Orthopaedic Clinic, Adelaide, South Australia Twenty patients

More information

MEDICAL POLICY SUBJECT: COMPUTER ASSISTED NAVIGATION FOR KNEE AND HIP ARTHROPLASTY

MEDICAL POLICY SUBJECT: COMPUTER ASSISTED NAVIGATION FOR KNEE AND HIP ARTHROPLASTY MEDICAL POLICY PAGE: 1 OF: 5 If the member's subscriber contract excludes coverage for a specific service it is not covered under that contract. In such cases, medical policy criteria are not applied.

More information

Shaoqi Tian 1*, Bin Wang 2, Yuanhe Wang 1, Chengzhi Ha 1, Lun Liu 1 and Kang Sun 1*

Shaoqi Tian 1*, Bin Wang 2, Yuanhe Wang 1, Chengzhi Ha 1, Lun Liu 1 and Kang Sun 1* Tian et al. BMC Musculoskeletal Disorders (2016) 17:327 DOI 10.1186/s12891-016-1186-5 RESEARCH ARTICLE Open Access Combined unicompartmental knee arthroplasty and anterior cruciate ligament reconstruction

More information

Unicompartmental Knee Replacement

Unicompartmental Knee Replacement Unicompartmental Knee Replacement Results and Techniques Alexander P. Sah, MD California Orthopaedic Association Meeting Laguna Niguel, CA May 20th, 2011 Overview Why partial knee replacement? - versus

More information

Statistical Validation of the Grand Rapids Arch Collapse Classification

Statistical Validation of the Grand Rapids Arch Collapse Classification Statistical Validation of the Grand Rapids Arch Collapse Classification David Burkard, BS Michelle Padley, CRTM John Anderson, MD Donald Bohay, MD John Maskill, MD Daniel Patton, MD Orthopaedic Associates

More information

Dr. Ashish Shah MD Dr. John Kirchner MD Dr. Sameer Naranje MD

Dr. Ashish Shah MD Dr. John Kirchner MD Dr. Sameer Naranje MD Dr. Ashish Shah MD Dr. John Kirchner MD Dr. Sameer Naranje MD Assistant Professor, UAB Orthopaedic Surgery, Foot & Ankle Section, 1313 13th Street South, Birmingham, AL 35205 Clinical Instructor Fellow,

More information

Revision of the humeral component for aseptic loosening in arthroplasty of the shoulder

Revision of the humeral component for aseptic loosening in arthroplasty of the shoulder Revision of the humeral component for aseptic loosening in arthroplasty of the shoulder A. Cil, C. J. H. Veillette, J. Sanchez-Sotelo, J. W. Sperling, C. Schleck, R. H. Cofield From the Mayo Clinic, Rochester,

More information

MEDICAL POLICY SUBJECT: COMPUTER ASSISTED NAVIGATION FOR KNEE AND HIP ARTHROPLASTY

MEDICAL POLICY SUBJECT: COMPUTER ASSISTED NAVIGATION FOR KNEE AND HIP ARTHROPLASTY MEDICAL POLICY SUBJECT: COMPUTER ASSISTED PAGE: 1 OF: 5 If a product excludes coverage for a service, it is not covered, and medical policy criteria do not apply. If a commercial product, including an

More information

National Joint Replacement Registry. Outcomes of Classes No Longer Used Hip and Knee Arthroplasty SUPPLEMENTARY

National Joint Replacement Registry. Outcomes of Classes No Longer Used Hip and Knee Arthroplasty SUPPLEMENTARY National Joint Replacement Registry Outcomes of Classes No Longer Used Hip and Knee Arthroplasty SUPPLEMENTARY Report 2017 AOAnjrr 2016 supplementary report AOAnjrr 2016 supplementary report Contents SUMMARY...

More information

Retrospective Study of Patellar Tracking in an Anatomical, Motion Guided Total Knee Design. Adam I. Harris, M.D. & Michelle Ammerman

Retrospective Study of Patellar Tracking in an Anatomical, Motion Guided Total Knee Design. Adam I. Harris, M.D. & Michelle Ammerman Retrospective Study of Patellar Tracking in an Anatomical, Motion Guided Total Knee Design Adam I. Harris, M.D. & Michelle Ammerman History: The Total Condylar knee represented a significant advance in

More information

Knee Revision. Portfolio

Knee Revision. Portfolio Knee Revision Portfolio I use the DePuy Revision Knee System because of its versatility. With this system I can solve nearly any situation I encounter in the OR. Dr. Thomas Fehring, OrthoCarolina Hip and

More information

Pulsed lavage reduces the incidence of radiolucent lines under the tibial tray of Oxford unicompartmental knee arthroplasty

Pulsed lavage reduces the incidence of radiolucent lines under the tibial tray of Oxford unicompartmental knee arthroplasty DOI 10.1007/s00264-009-0736-y ORIGINAL PAPER Pulsed lavage reduces the incidence of radiolucent lines under the tibial tray of Oxford unicompartmental knee arthroplasty Pulsed lavage versus syringe lavage

More information