ORIGINAL ARTICLE. Corneal Refractive Therapy with Different Lens Materials, Part 1: Corneal, Stromal, and Epithelial Thickness Changes

Size: px
Start display at page:

Download "ORIGINAL ARTICLE. Corneal Refractive Therapy with Different Lens Materials, Part 1: Corneal, Stromal, and Epithelial Thickness Changes"

Transcription

1 /07/ /0 VOL. 84, NO. 4, PP OPTOMETRY AND VISION SCIENCE Copyright 2007 American Academy of Optometry ORIGINAL ARTICLE Corneal Refractive Therapy with Different Lens Materials, Part 1: Corneal, Stromal, and Epithelial Thickness Changes SAMEENA HAQUE, PhD, BSc, MCOptom, DESMOND FONN, DipOptom Moptom, FAAO, TREFFORD SIMPSON, PhD, DipOptom, FAAO, and LYNDON JONES, PhD, FCOptom, FAAO Centre for Contact Lens Research, School of Optometry, University of Waterloo, Waterloo, Ontario, Canada ABSTRACT Purpose. To assess the corneal swelling response to two myopic correction corneal refractive therapy (CRT) lenses of varying Dk/t values, worn for a single night. Change in thickness of the total cornea, stroma, and epithelium was measured across the horizontal meridian using optical coherence tomography (OCT). Methods. In this double-masked, randomized study, twenty subjects wore a CRT design lens in each eye, manufactured from Menicon Z (MenZ; Dk/t 91) and Equalens II (EqII; Dk/t 47) materials. Baseline corneal thickness was measured centrally and at four points either side of the central cornea using OCT, the night before sleeping at the Centre for Contact Lens Research. The next morning, lenses were removed, and thickness measurements were repeated 1, 3, 6, and 12 h after removal. Results. On lens removal, the MenZ eye had central and paracentral corneal swelling (mean SD) of % and %, and the EqII eye had % and %. These values were significantly different from baseline (ReANOVA; p 0.001) and were different between lens materials (p 0.001). The central epithelium thinned by % in the MenZ eye and by % in the EqII eye, with the mid-peripheral epithelium thickening by % in the MenZ eye and % in the EqII eye (all changes different from baseline p 0.001). These epithelial values were not statistically different between materials (p 0.05). Stromal swelling values on lens removal were % centrally and % mid-peripherally (MenZ) and % centrally and % mid-peripherally (EqII) (all p from baseline). Central stromal swelling was different between eyes at lens removal (p 0.001). Stromal thickness in both eyes returned to baseline values within 3 h. Conclusion. The higher-dk/t MenZ material caused significantly less overnight corneal and stromal swelling than the Eqll material, which reinforces the need to prescribe lenses with high Dk/t for overnight wear. Neither central epithelial thinning nor paracentral thickening are significantly affected by Dk/t. (Optom Vis Sci 2007;84: ) Key Words: orthokeratology, corneal refractive therapy, optical coherence tomography, oxygen transmission, epithelium, corneal swelling Corneal refractive therapy (CRT) is a modern form of orthokeratology, in which rigid gas permeable (RGP) contact lenses are worn overnight to reduce refractive error. 1 3 In the treatment of myopia, attempts are made to flatten the central cornea. 2,4 The reduction in myopia is temporary, with regression occurring slowly throughout the day after removal of the CRT lens; however, regression is dependent on how long the lens is worn. 2,5,6 CRT lenses are currently approved for overnight wear, being typically worn during the night and removed every morning. Overnight wear of lenses clearly places an extra physiological burden upon the cornea, which makes oxygen transmissibility all the more critical to minimize corneal swelling. The degree to which oxygen may pass through a contact lens is governed by its oxygen transmissibility [Dk/t units 10 9 (cm ml O 2 )(s ml mm Hg)]. 7 One method of assessing the effect of oxygen transmissibility of a contact

2 344 Corneal Refractive Therapy: Thickness Changes Haque et al. lens is measuring the amount of corneal swelling that occurs after overnight lens wear, in addition to the normal physiological edema that results from eye closure after sleep. Normal physiological overnight corneal swelling is approximately 3 to 4% Two decades ago, Holden and Mertz 8 established the critical minimum oxygen transmissibility for overnight wear of contact lenses at (cm ml O 2 )(s ml mm Hg). However, more recent studies have suggested that they may have underestimated the value needed to avoid lens-induced corneal swelling. 7,10,15 CRT lenses (Paragon Vision Sciences) approved for use in North America are manufactured from the HDS100 material (fluorosilicone acrylate), and have a central Dk/t of only 67. Our previous studies investigating the clinical performance of the Paragon CRT design have shown that the central and paracentral cornea swells by 5 to 7% upon eyeopening, 5,6 supporting the notion that they provide insufficient oxygen. To date, few studies have reported the impact of increased oxygen transmissibility on corneal swelling during overnight orthokeratology lens wear The purpose of this study was to measure corneal, stromal, and epithelial thickness changes after a single night of CRT lens wear for the treatment of myopia. Two different lenses were used, consisting of the same design but manufactured from two different materials, one with a higher Dk/t than the other. Optical coherence tomography (OCT) was used to measure the corneal thickness changes, as previously described. 5,6,19 Instrumentation and Lenses A Humphrey-Zeiss OCT 2 system (Humphrey Systems, Dublin, CA) was used to measure corneal thickness across the horizontal meridian at nine points. A fixation device mounted on the OCT instrument aided in the capture of peripheral images, as described previously. 5 Subjects were asked to fixate each LED on the fixation device, while a video monitor aided in the alignment of the incident beam on the correct corneal location and the image was captured. Each cross-sectional scan of the cornea was 1.13 mm in length and enabled the compilation of a thickness profile of the cornea along the horizontal meridian. Each eye of all subjects was fitted with a CRT lens of the Paragon design (Paragon Vision Sciences, Mesa, AZ) and randomly chosen to wear either a lens manufactured from the Equalens II material (Bausch & Lomb, Rochester, NY) or the Menicon Z material (Menicon, Nagoya, Japan). The Equalens II (EqII) lens material (fluorosilicone acrylate) had a Dk of , and the Menicon Z (MenZ) lens material (fluorosiloxanylstyrene) had a Dk of (Fatt polarographic method without edge correction). Both lenses had a center thickness of 0.18 mm. The lenses were fitted using the manufacturer s guidelines to achieve appropriate apical touch (4 mm), mid-peripheral clearance, adequate edge lift, and proper centration. The lens parameters are listed in Table 2. MATERIALS AND METHODS Subjects Twenty subjects were enrolled (13 females and 7 males; mean age years; ranging from 19 to 35 years). Neophytes and soft lens wearers were recruited, but current RGP lens wearers were excluded. This research was conducted after the tenets of the Declaration of Helsinki. Informed consent was obtained from each individual and ethics clearance was obtained from the Office of Research Ethics at the University of Waterloo, before commencement of the study. Each subject presented without history of ocular disease or surgery. Refractive error of participants was restricted to a spherical range of 1.00 to 6.00, with no more than 1.75-D cylinder. Mean baseline corneal parameters for the cohort are displayed in Table 1. TABLE 1. Baseline ocular parameters for the cohort Baseline ocular parameters (mean SD) Menicon Z Equalens II Refractive error Sphere (D) Cylinder (D) Keratometry Flat K (D) Cyl (D) Central corneal thickness ( m) Central epithelial thickness ( m) Procedures In the evening before sleeping at our facility, baseline measurements for corneal thickness were obtained. The CRT lenses were placed on eye and the participants slept at 10 p.m., to be woken at 7 a.m. the next morning. On waking, the subjects were asked to keep their eyes closed until the lenses were removed one at a time at the OCT instrument and corneal measurements taken. These were repeated 1, 3, 6, and 12 h after lens removal. Data Analysis Raw data files captured by the OCT were processed using custom software as described previously. 5,6,19 Corneal and epithelial thickness changes were expressed as a percentage change, compared to baseline. 5 Statistical analysis of the thickness measurements was performed using Statistica 7.0 (Statsoft Inc, Tulsa, OK). Repeated measures analysis of TABLE 2. CRT lens parameters Menicon Z Equalens II BOZR (mm) (mean SD) Return zone depth ( m) (mean SD) Landing zone angle (degrees) (mean SD) Total diameter (mm) Center thickness (mm) Power (D) Dk/t (10 9 barrers/cm) BOZR, back optic zone radius; Dk/t, oxygen transmissibility.

3 Corneal Refractive Therapy: Thickness Changes Haque et al. 345 FIGURE 1. Change in total corneal thickness after CRT lens wear using two different lens materials. variance (Re-ANOVA), Tukey Honestly Significant Difference (HSD) post hoc testing, and paired t tests were used to analyze the changes in thickness from baseline levels over the study period. The level for statistical significance was set at RESULTS All 20 subjects completed the study. At lens removal, the central and paracentral corneal swelling (mean SD) of the MenZ lens wearing eye was % and %, respectively, (ReANOVA; both p from baseline). Corneal swelling in response to the EqII lens was % and %, respectively (both p from baseline) (Fig. 1). (Paracentral values were taken as the average of the two nasal and two temporal points closest to the center.) These values were significantly different between lens materials (p 0.01). Corneal swelling from both lenses had returned to baseline levels within 3hoflens removal (p 0.05), as shown in Fig. 1. Stromal swelling in the MenZ wearing eye was % centrally and % paracentrally, and in the EqII-wearing eye, the stroma swelled by % centrally and % paracentrally after lens removal (all p from baseline) (Fig. 2). In comparing both lens materials, the central and paracentral stromal swelling caused by the EqII lens was significantly greater than that caused by the MenZ lens (both p 0.05). Stromal swelling from both lenses had returned to baseline levels within 3 h after lens removal (p 0.05), as shown in Fig. 2. On lens removal, the central epithelium had thinned by % in the MenZ wearing eye and similarly by % in the EqII wearing eye (both p 0.001, compared to baseline) (Fig. 3). There was no difference in epithelial thinning between lenses (p 0.05). The paracentral epithelium thickened by % in the MenZ wearing eye and % in the EqII wearing eye (both p from baseline). Paracentral epithelial thickening was not statistically significant between lens materials (p 0.21). After 12 h, the central epithelium had not completely returned to baseline levels, being still % thinner in the MenZ eye (p 0.05 from baseline) and % thinner in the EqII eye (p 0.05 from baseline). The paracentral epithelium in the MenZ eye had recovered to baseline levels after 12 h ( %, p 0.05), but in the EqII eye, it remained significantly thicker than baseline ( %, p 0.05). DISCUSSION This single night study compared two identically designed CRT lenses for the reduction of myopia manufactured from two lens materials of differing oxygen transmissibility (Dk/t). The work of Holden and Mertz 8,9 and Harvitt and Bonanno 7 suggested that an oxygen transmissibility of between 87 and is necessary to prevent overnight hypoxia and subsequent corneal swelling induced by the lens. The degree of stromal and corneal swelling measured in this study supports their suggestions, in that both lenses exhibited greater swelling than has been reported for average overnight corneal swelling of 3 to 4% without lens wear These results show that oxygen transmissibility has a significant effect on corneal swelling after overnight wear of CRT contact lenses. The central and paracentral corneal and stromal swelling induced by the Equalens II lens was higher than that induced by the Menicon Z lens (Figs. 1 and 2). Recently, Lum and Swarbrick 18 also compared two orthokeratology lenses of differing Dk/t (46 vs. 26 units), and concluded that

4 346 Corneal Refractive Therapy: Thickness Changes Haque et al. FIGURE 2. Stromal swelling and recovery after CRT lens wear using two different lens materials. lens Dk/t influenced the clinical outcome after overnight wear. In their study, the lens of higher Dk/t produced less central stromal swelling (2.3% vs. 5.7%, measured with the Holden-Payor optical pachymeter). The amount of swelling measured after 2 weeks of lens wear was reduced, which may be due to an adaptation to the reduced oxygen available. Our group has previously reported a similar observation during 4 weeks of myopic CRT lens wear. 5 FIGURE 3. Change in epithelial thickness after CRT lens wear using two different lens materials.

5 Corneal Refractive Therapy: Thickness Changes Haque et al. 347 CRT or orthokeratology lenses, when designed to reduce myopia will flatten the central area of the cornea resulting in suppression of central corneal swelling during overnight wear. 20 This is as a result of the mechanical pressure from the eyelid and lens on the central part of the cornea during eye closure. However, the pressure effects do not seem to extend much beyond the epithelium. This can be seen by comparing the profile thicknesses of the epithelium, stroma, and cornea in the three figures. The stromal thickness profiles from both lenses show more typical swelling profiles compared with the corneal profiles that show less central than paracentral swelling. This is partly due to the influence of the epithelial changes, which thinned centrally and thickened paracentrally. The change in central epithelial thickness did not differ between lenses, with each producing 10% epithelial thinning after lens removal. This value is slightly higher than that reported in a previous study where subjects also only wore the lenses for one night. 5 However, other investigators have measured as much as 32% central epithelial thinning after one night of lens wear. 21 Many lenses currently available are manufactured from the Boston XO material (Bausch & Lomb, NY) with a Dk of 100 (e.g., Contex OK, DreamLens, BE Retainer) and thus a Dk/t of approximately 67. Tahhan et al. 22 and Soni et al. 23 have compared these different lens designs and found little difference in the effectiveness of the procedure for myopic correction. Identical lens designs are not expected to lead to differences in refractive effects. 22,23 Mid-peripheral epithelial changes were dissimilar between EqII lens wear (18%) and with MenZ lens wear (13%), although this difference did not reach statistical significance. The paracentral area of epithelial thickening corresponds to the return (clearance) zone of the lens between the central bearing area and the landing (peripheral alignment curve) zone, which is 1 mm wide. It is within this clearance zone that the epithelium thickens (Fig. 3). There are a number of possible reasons for the thickening. The most likely is the negative pressure in this tear layer space causing the epithelium to bulge as described by Mountford. 4 Another possibility is the central lens bearing forces, redistributing the epithelial cells from the center outward into the space of the clearance area. The third reason for the localized increase in epithelial thickness is due to hypoxia. However, this is the least likely reason as the majority of in vivo studies have shown that the epithelium does not thicken in response to hypoxia Recovery of corneal and stromal swelling occurred within 3 hours after lens removal, as has been reported in previous studies. 5,6 Results from this study showed that epithelial recovery was more gradual and incomplete, which is also in agreement with previous reports. 5,21,27,28 In conclusion, this study has shown effects of CRT lens wear on corneal and epithelial thickness after a single night of wear, comparing two different Dk lens materials. There were differences in corneal and stromal swelling induced by the two lenses, but no differences in central epithelial thinning or paracentral thickening. The results of this study reinforce the need to prescribe lenses with the highest oxygen transmissibility if they are to be worn overnight. ACKNOWLEDGEMENTS This work was supported by Menicon, Paragon Vision Sciences and an equipment grant from the Canada Foundation for Innovation (CFI). This work was presented as a lecture at the American Academy of Optometry (AAO) annual meeting in San Diego, CA, on Friday, December 8, 2005 (Program number: ). None of the authors of this study have any financial or other interests/ arrangements with the products/companies mentioned in the manuscript. Received July 7, 2006; revision received September 5, REFERENCES 1. Dave T, Ruston D. Current trends in modern orthokeratology. Ophthalmic Physiol Opt 1998;18: Swarbrick HA, Wong G, O Leary DJ. Corneal response to orthokeratology. Optom Vis Sci 1998;75: Mountford J. Orthokeratology. In: Phillips A, Speedwell L, eds. Contact Lenses. Oxford: Butterworth-Heinemann; 1997: Mountford J. An analysis of the changes in corneal shape and refractive error induced by accelerated orthokeratology. Int Contact Lens Clin 1997;24: Haque S, Fonn D, Simpson T, Jones L. Corneal and epithelial thickness changes after 4 weeks of overnight corneal refractive therapy lens wear, measured with optical coherence tomography. Eye Contact Lens 2004;30: Wang J, Fonn D, Simpson TL, Sorbara L, Kort R, Jones L. Topographical thickness of the epithelium and total cornea after overnight wear of reverse-geometry rigid contact lenses for myopia reduction. Invest Ophthalmol Vis Sci 2003;44: Harvitt DM, Bonanno JA. Re-evaluation of the oxygen diffusion model for predicting minimum contact lens Dk/t values needed to avoid corneal anoxia. Optom Vis Sci 1999;76: Holden BA, Mertz GW. Critical oxygen levels to avoid corneal edema for daily and extended wear contact lenses. Invest Ophthalmol Vis Sci 1984;25: Mertz GW. Overnight swelling of the living human cornea. J Am Optom Assoc 1980;51: Fonn D, Bruce AS. A review of the Holden-Mertz criteria for critical oxygen transmission. Eye Contact Lens 2005;31: Bruce AS, Brennan NA. Epithelial, stromal, and endothelial responses to hydrogel extended wear. CLAO J 1993;19: du Toit R, Vega JA, Fonn D, Simpson T. Diurnal variation of corneal sensitivity and thickness. Cornea 2003;22: Graham AD, Fusaro RE, Polse KA, Lin MC, Giasson CJ. Predicting extended wear complications from overnight corneal swelling. Invest Ophthalmol Vis Sci 2001;42: Moezzi AM, Fonn D, Simpson TL, Sorbara L. Contact lens-induced corneal swelling and surface changes measured with the Orbscan II corneal topographer. Optom Vis Sci 2004;81: Fonn D, Sweeney D, Holden BA, Cavanagh D. Corneal oxygen deficiency. Eye Contact Lens 2005;31: Swarbrick HA. Orthokeratology review and update. Clin Exp Optom 2006;89: Swarbrick HA, Jayakumar J, Co W, He D, Siu C, Yau B. Overnight corneal edema can modulate the short-term clinical response to orthokeratology lens wear. Invest Ophthalmol Vis Sci 2005;46:Eabstract Swarbrick HA, Lum E. Lens Dk/t influences the clinical response in overnight orthokeratology. Invest Ophthalmol Vis Sci 2006;47:E-abstract Wang J, Fonn D, Simpson TL. Topographical thickness of the epithelium and total cornea after hydrogel and PMMA contact lens wear with eye closure. Invest Ophthalmol Vis Sci 2003;44: Alharbi A, La Hood D, Swarbrick HA. Overnight orthokeratology lens wear can inhibit the central stromal edema response. Invest Ophthalmol Vis Sci 2005;46: Soni PS, Nguyen TT, Bonanno JA. Overnight orthokeratology: visual and corneal changes. Eye Contact Lens 2003;29:

6 348 Corneal Refractive Therapy: Thickness Changes Haque et al. 22. Tahhan N, Du Toit R, Papas E, Chung H, La Hood D, Holden AB. Comparison of reverse-geometry lens designs for overnight orthokeratology. Optom Vis Sci 2003;80: Soni PS, Nguyen TT. Overnight orthokeratology experience with XO material. Eye Contact Lens 2006;32: O Leary DJ, Wilson G, Henson DB. The effect of anoxia on the human corneal epithelium. Am J Optom Physiol Opt 1981;58: Wang J, Fonn D, Simpson TL, Jones L. The measurement of corneal epithelial thickness in response to hypoxia using optical coherence tomography. Am J Ophthalmol 2002;133: Wilson G, Fatt I. Thickness of the corneal epithelium during anoxia. Am J Optom Physiol Opt 1980;57: Barr JT, Rah MJ, Meyers W, Legerton J. Recovery of refractive error after corneal refractive therapy. Eye Contact Lens 2004;30: Nichols JJ, Marsich MM, Nguyen M, Barr JT, Bullimore MA. Overnight orthokeratology. Optom Vis Sci 2000;77: Desmond Fonn Centre for Contact Lens Research School of Optometry University of Waterloo 200 University Avenue West Waterloo, Ontario N2L 3G1, Canada dfonn@uwaterloo.ca

Corneal Swelling Response to Contact Lenses Worn Under Extended Wear Conditions

Corneal Swelling Response to Contact Lenses Worn Under Extended Wear Conditions Corneal Swelling Response to Contact Lenses Worn Under Extended Wear Conditions Drien A. Holden, George W. Merrz, and John J. McNolly Corneal thickness changes were monitored in ten subjects (1) over a

More information

Essentials of Orthokeratology

Essentials of Orthokeratology Essentials of Orthokeratology Essentials of Orthokeratology Disclosures: Alcon Bausch + Lomb Contamac CooperVision Johnson & Johnson SpecialEyes Valley Contax Matthew J. Lampa, OD, FAAO lampa@pacificu.edu

More information

The Current State of Corneal Reshaping

The Current State of Corneal Reshaping Eye & Contact Lens 31(5): 209 214, 2005 2005 Contact Lens Association of Ophthalmologists, Inc. The Current State of Corneal Reshaping Jeffrey J. Walline, OD, PhD, Brien A. Holden, BAppSc, PhD, Mark A.

More information

FITTING GUIDE & TIPS FOR ACHIEVING SUCCESS

FITTING GUIDE & TIPS FOR ACHIEVING SUCCESS AT M hybrid contact lens for astigmatism FITTING GUIDE & TIPS FOR ACHIEVING SUCCESS AT M hybrid contact lens for astigmatism Contents Overview 2 Patient Candidates 2 Key Features of SynergEyes A 3 SynergEyes

More information

Contact lens extended wear (EW) creates a stressful environment

Contact lens extended wear (EW) creates a stressful environment Impact of Rigid Gas-Permeable Contact Lens Extended Wear on Corneal Epithelial Barrier Function Meng C. Lin, 1 Andrew D. Graham, 1 Robert E. Fusaro, 2 and Kenneth A. Polse 1 From the 1 School of Optometry

More information

Central and Peripheral Changes in Anterior Corneal Topography after Orthokeratology and Laser in situ Keratomileusis

Central and Peripheral Changes in Anterior Corneal Topography after Orthokeratology and Laser in situ Keratomileusis Central and Peripheral Changes in Anterior Corneal Topography after Orthokeratology and Laser in situ Keratomileusis Han-Yin Sun 1, 2, 3, Hsiu-Wan Yang 4, I-Tsung Wu 4, Jung-Kai Tseng 2, 3 1, 5* and Shun-Fa

More information

Myopia Management. Michael J. Lipson OD FAAO FSLS

Myopia Management. Michael J. Lipson OD FAAO FSLS Myopia Management Michael J. Lipson OD FAAO FSLS Disclosure I am a consultant to Bausch and Lomb - Specialty Lens Products Division I am on the advisory board of the GPLI I have received research funding

More information

Uncovering Contact Lens Discoveries. Joe Barr, OD, MS, FAAO. Key findings of Donald Korb, OD and the presenter s and colleague s work that he inspired

Uncovering Contact Lens Discoveries. Joe Barr, OD, MS, FAAO. Key findings of Donald Korb, OD and the presenter s and colleague s work that he inspired Uncovering Contact Lens Discoveries Joe Barr, OD, MS, FAAO Dr. Donald R. Korb Award for Excellence Lecture June 30, 2016 Key findings of Donald Korb, OD and the presenter s and colleague s work that he

More information

Accuracy and Repeatability of a New Portable Ultrasound Pachymeter

Accuracy and Repeatability of a New Portable Ultrasound Pachymeter Accuracy and Repeatability of a New Portable Ultrasound Pachymeter Queirós A 1, González-Méijome JM 1, Fernandes P 1, Jorge J 1, Almeida J B 1, Parafita MA 2 1 Department of Physics (Optometry), School

More information

MYOPIA AFFECTS APproximately

MYOPIA AFFECTS APproximately CLINICAL TRIALS SECTION EDITOR: ROY W. BECK, MD, PhD A Randomized Trial of the Effects of Rigid Contact Lenses on Progression Jeffrey J. Walline, OD, PhD; Lisa A. Jones, PhD; Donald O. Mutti, OD, PhD;

More information

Scleral Lens Essentials

Scleral Lens Essentials Scleral Lens Essentials Disclosures: Alcon Bausch + Lomb Contamac CooperVision Johnson & Johnson SpecialEyes Valley Contax Matthew J. Lampa, OD, FAAO lampa@pacificu.edu Scleral Lenses Which Lens Modality???

More information

Management of Myopia in Adolescent. Non Invasive Kerato- Refractive Procedures. Early Orthokeratology. Sami El Hage, PhD, DSc, OD FAAO,FAAS,FAAOMC

Management of Myopia in Adolescent. Non Invasive Kerato- Refractive Procedures. Early Orthokeratology. Sami El Hage, PhD, DSc, OD FAAO,FAAS,FAAOMC Management of Myopia in Adolescent Sami El Hage, PhD, DSc, OD FAAO,FAAS,FAAOMC Eye Care Associates Houston, Texas 77056 ASCRS 2015 Non Invasive Kerato- Refractive Procedures CKR/Modern Orthokeratology

More information

Jason R. Miller, OD, MBA, FAAO. Innovations in Specialty, Irregular Corneas & KCN with Contact Lenses

Jason R. Miller, OD, MBA, FAAO. Innovations in Specialty, Irregular Corneas & KCN with Contact Lenses Jason R. Miller, OD, MBA, FAAO Innovations in Specialty, Irregular Corneas & KCN with Contact Lenses Developing Optometric Subspecialties CL market overview and trends Specialty Lenses Irregular Corneas

More information

Orthokeratology is defined as the temporary. Pseudomonas aeruginosa Corneal Ulcer Related to Overnight Orthokeratology

Orthokeratology is defined as the temporary. Pseudomonas aeruginosa Corneal Ulcer Related to Overnight Orthokeratology Original Article 182 Pseudomonas aeruginosa Corneal Ulcer Related to Overnight Orthokeratology Ching-Hsi Hsiao, MD; Lung-Kun Yeh, MD; An-Ning Chao, MD; Yeong-Fong Chen, MD; Ken-Kuo Lin, MD Background:

More information

Biometric Risk Factors for Corneal Neovascularization Associated with Hydrogel Soft Contact Lens Wear in Korean Myopic Patients

Biometric Risk Factors for Corneal Neovascularization Associated with Hydrogel Soft Contact Lens Wear in Korean Myopic Patients pissn: 1011-8942 eissn: 2092-9382 Korean J Ophthalmol 2014;28(4):292-297 http://dx.doi.org/10.3341/kjo.2014.28.4.292 Original Article Biometric Risk Factors for Corneal Neovascularization Associated with

More information

Essential Scleral Lens Knowledge

Essential Scleral Lens Knowledge Essential Scleral Lens Knowledge Precilens consultant Bausch and Lomb research Contact Lens Residents Forum Director for Alden Optical Brooke Messer, OD, FAAO, FSLS Cornea and Contact Lens Institute of

More information

Myopia has become a worldwide public health issue. In

Myopia has become a worldwide public health issue. In REVIEW ARTICLE A Review of the Potential Factors Influencing Myopia Progression in Children Using Orthokeratology Xiao Yang, MD, Zhouyue Li, MD, and Junwen Zeng, PhD Abstract: Myopia has become a worldwide

More information

Colleen Riley, O.D., M.S., F.A.A.O., Graeme Young, M.Phil., Ph.D., F.C.Optom., D.C.L.P., F.A.A.O., and Robin Chalmers, O.D., F.A.A.O.

Colleen Riley, O.D., M.S., F.A.A.O., Graeme Young, M.Phil., Ph.D., F.C.Optom., D.C.L.P., F.A.A.O., and Robin Chalmers, O.D., F.A.A.O. Eye & Contact Lens 32(6): 281 286, 2006 2006 Contact Lens Association of Ophthalmologists, Inc. Prevalence of Ocular Surface Symptoms, Signs, and Uncomfortable Hours of Wear in Contact Lens Wearers: The

More information

MiSight 1 day - Live Webinar Q&A

MiSight 1 day - Live Webinar Q&A What age does the child stop needing treatment? Our current published research tracks children up to 15 years of age and the data shows that myopia is still progressing in both MiSight and single vision

More information

Statistical data in the field of orthokeratology and myopia control in the U.S. and in the world

Statistical data in the field of orthokeratology and myopia control in the U.S. and in the world Statistical data in the field of orthokeratology and myopia control in the U.S. and in the world - The challenges that Korean orthokeratology community are facing - Ways to tackle the challenges in most

More information

Central corneal thickness (CCT) measurement is a critical

Central corneal thickness (CCT) measurement is a critical ARTICLE Topographic Paracentral Corneal Thickness With Pentacam and Orbscan: Effect of Acoustic Factor Javier González-Pérez, O.D., M.Sc., Ph.D., Jose M. González-Méijome, O.D., Ph.D., María T. Rodríguez

More information

Does the cornea take part in the accommodation of the myopic eye?

Does the cornea take part in the accommodation of the myopic eye? Does the cornea take part in the accommodation of the myopic eye?.a.arasova, E.P.arutta, E..Iomdina,.V.Khodzhabekyan Moscow Helmholtz Research Institute of Eye Diseases, Russia Introduction. According

More information

Scleral Lenses: How do you know what is best

Scleral Lenses: How do you know what is best Scleral Lenses: How do you know what is best Alan Kwok, OD, FAAO, FSLS Tar Vaz, OD, FAAO Please silence all mobile devices and remove items from chairs so others can sit. Unauthorized recording of this

More information

SynergEyes PS Practitioner Training

SynergEyes PS Practitioner Training SynergEyes PS Practitioner Training Post-Surgical Market For 30 years, visual scientists from around the world have struggled with the challenge of surgically correcting human refractive error. While great

More information

C L I N I C A L A N D E X P E R I M E N T A L OPTOMETRY

C L I N I C A L A N D E X P E R I M E N T A L OPTOMETRY C L I N I C A L A N D E X P E R I M E N T A L OPTOMETRY The characteristics of corneal staining in successful daily and extended disposable contact lens wearers Isabelle Jalbert OD Deborah F Sweeney BOptom

More information

SCLERAL CONTACT LENSES EPSILON SCLERAL

SCLERAL CONTACT LENSES EPSILON SCLERAL SCLERAL CONTACT LENSES EPSILON SCLERAL - Outstands due to multi aspheric variable eccentricity design - Fitted in two steps due to it s novel philosophy and diagnostic set - Reassures limbal stem cells

More information

C L I N I C A L A N D E X P E R I M E N T A L OPTOMETRY ORIGINAL PAPER. A market survey of contact lens practice in Hong Kong

C L I N I C A L A N D E X P E R I M E N T A L OPTOMETRY ORIGINAL PAPER. A market survey of contact lens practice in Hong Kong C L I N I C A L A N D E X P E R I M E N T A L Contact lens practice in Hong Kong Yung, Cho and Yap OPTOMETRY ORIGINAL PAPER A market survey of contact lens practice in Hong Kong Clin Exp Optom 5; 88: 3:

More information

Comparison of tear osmolarity and ocular comfort between daily disposable contact lenses: hilafilcon B hydrogel versus narafilcon A silicone hydrogel

Comparison of tear osmolarity and ocular comfort between daily disposable contact lenses: hilafilcon B hydrogel versus narafilcon A silicone hydrogel Int Ophthalmol (2012) 32:229 233 DOI 10.1007/s10792-012-9556-y ORIGINAL PAPER Comparison of tear osmolarity and ocular comfort between daily disposable contact lenses: hilafilcon B hydrogel versus narafilcon

More information

Measurement of Choroidal Thickness in Normal Eyes Using 3D OCT-1000 Spectral Domain Optical Coherence Tomography

Measurement of Choroidal Thickness in Normal Eyes Using 3D OCT-1000 Spectral Domain Optical Coherence Tomography pissn: 111-8942 eissn: 292-9382 Korean J Ophthalmol 212;26(4):255-259 http://dx.doi.org/1.3341/kjo.212.26.4.255 Original Article Measurement of Choroidal Thickness in Normal Eyes Using 3D OCT-1 Spectral

More information

Doctors of Optometry Course Notes

Doctors of Optometry Course Notes Doctors of Optometry Course Notes OD22 1 CE Contact Lens Management of the Irregular Cornea Monday, February 19, 2018 9:05 am 10:00 am Plaza A 2 nd Fl Presenter: Dr. Maria Walker Dr. Maria K. Walker earned

More information

MEDICAL POLICY SUBJECT: CORNEAL ULTRASOUND PACHYMETRY. POLICY NUMBER: CATEGORY: Technology Assessment

MEDICAL POLICY SUBJECT: CORNEAL ULTRASOUND PACHYMETRY. POLICY NUMBER: CATEGORY: Technology Assessment MEDICAL POLICY SUBJECT: CORNEAL ULTRASOUND,, PAGE: 1 OF: 5 If a product excludes coverage for a service, it is not covered, and medical policy criteria do not apply. If a commercial product, including

More information

Myopia Control An Update

Myopia Control An Update Lyndon Jones PhD, DSc, FCAHS, FCOptom, FAAO Financial Disclosures Myopia Control An Update Lyndon Jones PhD DSc FCAHS FCOptom FAAO Over the past three years, members of CORE have received research funding

More information

Erin Witte, O.D. This paper is submitted in partial fulfillment of the requirements for the post doctorate residency training of

Erin Witte, O.D. This paper is submitted in partial fulfillment of the requirements for the post doctorate residency training of EVALUATION OF THE COMFORT SL SCLERAL CONTACT LENS DESIGN by Erin Witte, O.D. This paper is submitted in partial fulfillment of the requirements for the post doctorate residency training of Cornea and Contact

More information

FEP Medical Policy Manual

FEP Medical Policy Manual FEP Medical Manual 9.03.05 Corneal Topography/Computer-Assisted Corneal Topography/ Photokeratoscopy Last Review: September 2016 Next Review: September 2017 Related Policies 9.03.28 Corneal Collagen Cross-linking

More information

Scleral contact lenses and their therapeutic use Part 1

Scleral contact lenses and their therapeutic use Part 1 CET Scleral contact lenses and their therapeutic use Part 1 How should a scleral lens be defined? A scleral contact lens (ScCL) has its bearing surface on the sclera and is fitted with no or minimal corneal

More information

2/3/2019. Contact Lenses in 2020 and Beyond: What Does the Future for Contacts Look Like? Summary. Wearable Sensor Market

2/3/2019. Contact Lenses in 2020 and Beyond: What Does the Future for Contacts Look Like? Summary. Wearable Sensor Market Lyndon Jones PhD, DSc, FCAHS, FCOptom, FAAO Financial Disclosures Contact Lenses in 2020 and Beyond: What Does the Future for Contacts Look Like? Lyndon Jones PhD DSc FCAHS FCOptom FAAO Professor & University

More information

NIH Public Access Author Manuscript Cornea. Author manuscript; available in PMC 2014 May 29.

NIH Public Access Author Manuscript Cornea. Author manuscript; available in PMC 2014 May 29. NIH Public Access Author Manuscript Published in final edited form as: Cornea. 2013 December ; 32(12): 1544 1548. doi:10.1097/ico.0b013e3182a7f39d. Repeatability of corneal epithelial thickness measurements

More information

Factors Determining Effective Orthokeratology Treatment for Controlling Juvenile Myopia Progression

Factors Determining Effective Orthokeratology Treatment for Controlling Juvenile Myopia Progression Iran J Public Health, Vol. 46, No.9, Sep 2017, pp.1217-1222 Original Article Factors Determining Effective Orthokeratology Treatment for Controlling Juvenile Myopia Progression Qinghui KONG 1, Jiang GUO

More information

SCL & GP Complications and Their Management

SCL & GP Complications and Their Management SCL & GP Complications and Their Management Prepared by: L. Jones PhD FCOptom DipCLP DipOrth FAAO (DipCL) FIACLE & L. Sorbara OD MSc FAAO (Dip C&CL) Presented by: M. Steenbakkers OD FAAO Causes of CL Complications

More information

SCLERAL LENS ASSESSMENT AND FITTING

SCLERAL LENS ASSESSMENT AND FITTING SCLERAL LENS ASSESSMENT AND FITTING Dr. Anita Gulmiri OD, FAAO Assistant Professor of Clinical Optometry New England College of Optometry This presentation has been created for Orbis International trainees

More information

Overnight Wear. key points. Essential Contact Lens Practice

Overnight Wear. key points. Essential Contact Lens Practice Medical Ltd Overnight Wear key points Key Points The risks and benefits of overnight wear should be discussed between the patient and practitioner to help enable an informed choice to be made Although

More information

aberration induced by laser

aberration induced by laser How is spherical aberration induced by laser refractive surgery? Geunyoung Yoon, PhD 1 Ian Cox, PhD 2 Scott MacRae,, MD 1 1 Department of Ophthalmology, Center for Visual Science University of Rochester,

More information

Orthokeratology for Controlling Myopia: Clinical Experiences

Orthokeratology for Controlling Myopia: Clinical Experiences Article Date: 5/1/2010 ORTHO-K AND MYOPIA CONTROL Orthokeratology for Controlling Myopia: Clinical Experiences Two practitioners observe results similar to that in the literature for controlling myopia

More information

ORIGINAL ARTICLE. Impact of Pupil Diameter on Axial Growth in Orthokeratology

ORIGINAL ARTICLE. Impact of Pupil Diameter on Axial Growth in Orthokeratology 1040-5488/12/8911-1636/0 VOL. 89, NO. 11, PP. 1636Y1640 OPTOMETRY AND VISION SCIENCE Copyright * 2012 American Academy of Optometry ORIGINAL ARTICLE Impact of Pupil Diameter on Axial Growth in Orthokeratology

More information

Cornea and Contact Lens Institute of Minnesota. Specialty Contact Lenses and Vision Management

Cornea and Contact Lens Institute of Minnesota. Specialty Contact Lenses and Vision Management Cornea and Contact Lens Institute of Minnesota Specialty Contact Lenses and Vision Management We focus on specialty contact lenses. is a leading national resource for specialized contact lenses and eye

More information

Keratoconus Clinic. Optometric Co-management Opportunities

Keratoconus Clinic. Optometric Co-management Opportunities Keratoconus Clinic Optometric Co-management Opportunities The Bochner Eye Institute established the first Keratoconus Clinic in Canada in 2008. The consultation and advanced imaging are OHIP covered. All

More information

This is the author s version of a work that was submitted/accepted for publication in the following source:

This is the author s version of a work that was submitted/accepted for publication in the following source: This is the author s version of a work that was submitted/accepted for publication in the following source: Alonso-Caneiro, David, Vincent, Stephen J., & Collins, Michael J. (2016) Morphological changes

More information

Scleral Contact Lenses for Technicians

Scleral Contact Lenses for Technicians Course Outline Scleral Contact Lenses for Technicians Aaron McNulty, OD, FAAO Louisville Eye Center Louisville, KY Why use scleral lenses? Introduction to scleral lenses Handling and cleaning sclerals

More information

Clinically Meaningful

Clinically Meaningful Myopia Control Myopia Control -19% -7% 18% 40% 42% 46% 76% Jeffrey J. Walline, OD PhD The Ohio State University College of Optometry Undercorrection GP Bifocal / PAL Pirenzepine Specs OK What is Clinically

More information

A New Method to Analyze the Relative Corneal Refractive Power and Its Association to Myopic Progression Control With Orthokeratology

A New Method to Analyze the Relative Corneal Refractive Power and Its Association to Myopic Progression Control With Orthokeratology Article https://doi.org/10.1167/tvst.7.6.17 A New Method to Analyze the Relative Corneal Refractive Power and Its Association to Myopic Progression Control With Orthokeratology Jinghui Wang 1, Dan Yang

More information

Methodologies for Interventional Myopia Studies

Methodologies for Interventional Myopia Studies 282 Commentary Methodologies for Interventional Myopia Studies Chong-Yew Khoo, 1 FRCOphth, FRACS, FAMS, Richard FS Ng, 2 BSc Abstract Myopia studies are notoriously difficult to carry out. Past studies

More information

Effect of Orthokeratology on myopia progression: twelve-year results of a retrospective cohort study

Effect of Orthokeratology on myopia progression: twelve-year results of a retrospective cohort study Lee et al. BMC Ophthalmology (2017) 17:243 DOI 10.1186/s12886-017-0639-4 RESEARCH ARTICLE Effect of Orthokeratology on myopia progression: twelve-year results of a retrospective cohort study Yueh-Chang

More information

Myopia Control. Disclosures. Prevalence. Cost. Prevalence. Bausch + Lomb: research materials

Myopia Control. Disclosures. Prevalence. Cost. Prevalence. Bausch + Lomb: research materials Disclosures Bausch + Lomb: research materials Myopia Control Jeffrey J. Walline, OD PhD The Ohio State University College of Optometry Myopia Control Prevalence From: nature.com http://www.nature.com/news/the-myopia-boom-1.17120

More information

Saving Eyes Without a Topographer:

Saving Eyes Without a Topographer: Saving Eyes Without a Topographer: Myopia Control in General Practice Alex Petty BOptom, FIAO Saving Eyes Without a Topographer: Myopia Control in General Practice Alex Petty BOptom, FIAO Alex s Background

More information

PHOTOREFRACTIVE KERATECTOMY (PRK) PATIENT INFORMATION BOOKLET

PHOTOREFRACTIVE KERATECTOMY (PRK) PATIENT INFORMATION BOOKLET 616.365.5775 www.keillasik.com PHOTOREFRACTIVE KERATECTOMY (PRK) PATIENT INFORMATION BOOKLET Please read this entire booklet. Discuss its contents with your doctor so that questions are answered to your

More information

Comparison of Central Corneal Thickness Measurements with Pentacam, Orbscan II, and Ultrasound Pachymeter

Comparison of Central Corneal Thickness Measurements with Pentacam, Orbscan II, and Ultrasound Pachymeter Comparison of Central Corneal Thickness Measurements with Pentacam, Orbscan II, and Ultrasound Pachymeter Abbas-Ali Yekta, PhD 1 Hassan Hashemi, MD 2,3 Mehdi KhabazKhoob, MSc 3 Asghar Dostdar, MSc 4 Shiva

More information

MYOPIA CONTROL Protect your child s future vision

MYOPIA CONTROL Protect your child s future vision MYOPIA CONTROL Protect your child s future vision WHAT IS MYOPIA For people who are myopic, near objects are clear while distant objects appear blurry. This is usually because the eye becomes too long

More information

Anterior segment imaging

Anterior segment imaging CET CONTINUING Sponsored by 1 CET POINT Anterior segment imaging Sundeep Vaswani, BSc (Hons), MCOptom 39 The anterior segment of the eye encompasses all structures from the front surface of the cornea

More information

The prevalence of myopia is high in East Asia (Hong Kong,

The prevalence of myopia is high in East Asia (Hong Kong, Cornea Myopia Control Using Toric Orthokeratology (TO-SEE Study) Connie Chen, Sin Wan Cheung, and Pauline Cho The Hong Kong Polytechnic University, School of Optometry, Hung Hom, Kowloon, Hong Kong, China

More information

Contact Lenses for Infants: Indication, Evaluation, and Technique

Contact Lenses for Infants: Indication, Evaluation, and Technique Contact Lenses for Infants: Indication, Evaluation, and Technique Maureen Plaumann, OD, FAAO The Ohio State University Elaine Chen, OD, FAAO, FSLS Southern California College of Optometry Marshall B. Ketchum

More information

Ocular Studies of EMF Exposure at the MMW M. Kojima 1,2,3), Y. Suzuki 4)

Ocular Studies of EMF Exposure at the MMW M. Kojima 1,2,3), Y. Suzuki 4) Ocular Studies of EMF Exposure at the MMW M. Kojima 1,2,3), Y. Suzuki 4) 1. Division of Vision Research for Environmental Health, Medical Research Institute, Kanazawa Medical University 2. Department of

More information

Myopia. As a practice that emphasizes. Slowing. Myopia Control

Myopia. As a practice that emphasizes. Slowing. Myopia Control Slowing Myopia Progression in Children Although you can t cure myopia, there are an increasing number of promising treatment options you can use to curtail it. By David Kading, O.D., and Amber Mayberry

More information

OPTOMETRY CASE REPORT. Circinate corneal scarring

OPTOMETRY CASE REPORT. Circinate corneal scarring OPTOMETRY CASE REPORT Circinate corneal scarring Clin Exp Optom 2004; 87: 1: 28-33 Sandra Codson* BOptom PgDipAdvClinOpt Adrian Bruce+ BScOptom PhD * Victorian College of Optometry, The University of Melbourne

More information

Contact Lenses for Infants: Indication, Evaluation, and Technique

Contact Lenses for Infants: Indication, Evaluation, and Technique Contact Lenses for Infants: Indication, Evaluation, and Technique Elaine Chen, OD, FAAO, FSLS Southern California College of Optometry Marshall B. Ketchum University Maureen Plaumann, OD, FAAO The Ohio

More information

Building a Myopia Control Practice. Andrew D. Pucker, OD, PhD, FAAO Assistant Professor

Building a Myopia Control Practice. Andrew D. Pucker, OD, PhD, FAAO Assistant Professor Building a Myopia Control Practice Andrew D. Pucker, OD, PhD, FAAO Assistant Professor Disclosures My research has been supported by the following organizations over the past three years: National Eye

More information

Limbal and Bulbar Hyperaemia in Normal Eyes

Limbal and Bulbar Hyperaemia in Normal Eyes Ophthal. Physiol. Opt. 2008 28: 13 20 Limbal and Bulbar Hyperaemia in Normal Eyes Heiko Pult 1, Paul J. Murphy 1, Christine Purslow 1, Jeffrey Nyman 2 and Russell L. Woods 3 1 Cardiff University, School

More information

Myopia Control. Disclosures. Myopia Control Summary. End of Lecture, You Will Be Able To. Soft Multifocal Myopia Control

Myopia Control. Disclosures. Myopia Control Summary. End of Lecture, You Will Be Able To. Soft Multifocal Myopia Control Disclosures Bausch + Lomb: research materials Myopia Control Jeffrey J. Walline, OD PhD The Ohio State University College of Optometry End of Lecture, You Will Be Able To Talk to parents about myopia control

More information

(877) Progress Drive Front Royal, VA A Revolution in Scleral Lens Fitting

(877) Progress Drive Front Royal, VA A Revolution in Scleral Lens Fitting www.visionary-optics.com/smap3d (877) 533-1509 1325 Progress Drive Front Royal, VA 22630 A Revolution in Scleral Lens Fitting The future of custom scleral contact lens fitting is here! I have had extraordinary

More information

Bilateral Microphthalmos Associated with Papillomacular Fold, Severe Hyperopia and Steep Cornea

Bilateral Microphthalmos Associated with Papillomacular Fold, Severe Hyperopia and Steep Cornea Bilateral Microphthalmos Associated with Papillomacular Fold, Severe Hyperopia and Steep Cornea Mojtaba Abrishami, MD 1 Alireza Maleki, MD 2 Ali Hamidian-Shoormasti, MD 3 Mostafa Abrishami, MD 4 Abstract

More information

See the future of myopia management

See the future of myopia management See the future of myopia management Contents Myopia: a global epidemic Introducing MiSight 1 day MiSight 1 day: the results (three years) 1 2 3 Myopia: A global epidemic UK: Over the last 50 years, myopia

More information

Corneal molding and riboflavin-uva collagen cross-linking in keratoconus

Corneal molding and riboflavin-uva collagen cross-linking in keratoconus Corneal molding and riboflavin-uva collagen cross-linking in keratoconus Antonio Calossi Department of Optics and Optometry, University of Turin, Italy Studio Optometrico Calossi, Certaldo (Florence),

More information

Epithelial metabolism of the corneal graft is abnormal

Epithelial metabolism of the corneal graft is abnormal British Journal of Ophthalmology, 1987, 71, 593-597 Epithelial metabolism of the corneal graft is abnormal ANTTI VANNAS,' BRIEN A HOLDEN,2 AND DEBORAH F SWEENEY2 From the' University Eye Clinic, Helsinki,

More information

OPTOMETRY ORIGINAL PAPER

OPTOMETRY ORIGINAL PAPER C L I N I C A L A N D E X P E R I M E N T A L OPTOMETRY ORIGINAL PAPER Repeatability and agreement of two A-scan ultrasonic biometers and IOLMaster in non-orthokeratology subjects and post-orthokeratology

More information

Clinical grading of corneal staining of non-contact lens wearers

Clinical grading of corneal staining of non-contact lens wearers www.elsevier.com/locate/ophopt PII: S0275-5408(00)00011-9 Ophthal. Physiol. Opt. Vol. 21, No. 1, pp. 30±35, 2001 q 2000 The College of Optometrists. Published by Elsevier Science Ltd All rights reserved.

More information

Evaluation of corneal thickness and topography in normal eyes using the Orbscan corneal topography system

Evaluation of corneal thickness and topography in normal eyes using the Orbscan corneal topography system 774 Ocular Surface and Tear Center, Bascom Palmer Eye Institute, University of Miami School of Medicine, Miami, USA Z Liu A J Huang S C Pflugfelder Zhongshan Ophthalmic Center, Sun Yat-sen University of

More information

Myopia Control. Financial Disclosures. Prevalence of Myopia 3/31/2019. Importance of Myopia Control. Myopia Control Treatment Options

Myopia Control. Financial Disclosures. Prevalence of Myopia 3/31/2019. Importance of Myopia Control. Myopia Control Treatment Options Financial Disclosures Myopia Control None Katherine Bickle, OD MS FAAO March 31, 2019 Prevalence of Myopia Importance of Myopia Control 42% of the United States population is myopic and 25% of children

More information

Learn Connect Succeed. JCAHPO Regional Meetings 2017

Learn Connect Succeed. JCAHPO Regional Meetings 2017 Learn Connect Succeed JCAHPO Regional Meetings 2017 Faculty Biometry and IOL Calculations ASCRS and ASOA Symposium and Congress Los Angeles, CA Daniel H. Chang, M.D. - Empire Eye and Laser Center Bakersfield,

More information

Role of Central Corneal Thickness in Circadian Intraocular Pressure Fluctuations among Patients with Primary Open Angle Glaucoma

Role of Central Corneal Thickness in Circadian Intraocular Pressure Fluctuations among Patients with Primary Open Angle Glaucoma Role of Central Corneal Thickness in Circadian Intraocular Pressure Fluctuations among Patients with Primary Open Angle Glaucoma Mohannad Albdour MD*, Karanjit Kooner MD, PHD** ABSTRACT Objectives: To

More information

Therapeutical bandage contact lenses for corneal protection

Therapeutical bandage contact lenses for corneal protection Therapeutical bandage contact lenses for corneal protection M i c h a e l B a e r t s c h i M.S.Optom Optom., M.Med.Educ Educ.,., F.A.A.O. Contact for text manuscript demands michael.baertschi baertschi@bluewin.ch

More information

Fitting Keratoconus and Other Complicated Corneas

Fitting Keratoconus and Other Complicated Corneas Fitting Keratoconus and Other Complicated Corneas Christine W Sindt OD FAAO Professor, Clinical Ophthalmology Director, Contact Lens Service University of Iowa Disclosure Consultant: ALCON Vision Care

More information

The Effects of Hydrophilic Contact Lens Wear on the Reduction of Progressive Myopia in Adolescents. by Bob Deck

The Effects of Hydrophilic Contact Lens Wear on the Reduction of Progressive Myopia in Adolescents. by Bob Deck The Effects of Hydrophilic Contact Lens Wear on the Reduction of Progressive Myopia in Adolescents by Bob Deck The purpose of this retrospective study was to evaluate the effects of hydrophilic contact

More information

From Dusk to Dawn: Contact Lenses in the Night Tear Proteome. Part 1: My Story

From Dusk to Dawn: Contact Lenses in the Night Tear Proteome. Part 1: My Story 1 From Dusk to Dawn: Contact Lenses in the Night Tear Proteome Part 1: My Story I saw the letter E, big, black and bold. Now read me line six, the nurse said, pointing to a row of blurry rectangles. I

More information

Low Plus Prescriptions - Summary of Evidence

Low Plus Prescriptions - Summary of Evidence Low Plus Prescriptions - Summary of Evidence By Steve Leslie BOptom, Leonard Press OD & Mark Overton Behavioural optometrists use low plus prescriptions to optimise near vision performance, based on well-established

More information

Hard Contact Lens Wear and the Risk of Acquired Blepharoptosis: A Case-Control Study

Hard Contact Lens Wear and the Risk of Acquired Blepharoptosis: A Case-Control Study Hard Contact Lens Wear and the Risk of Acquired Blepharoptosis: A Case-Control Study Takeshi Kitazawa, MD Department of Plastic and Reconstructive Surgery, Matsunami General Hospital, Gifu, Japan Correspondence:

More information

MANAGEMENT ACROSS THE POND NITESH BAROT

MANAGEMENT ACROSS THE POND NITESH BAROT MANAGEMENT ACROSS THE POND NITESH BAROT AGENDA EXPLAIN CORNEAL THERAPY PATIENTS ENQUIRY ABOUT CORNEAL THERAPY PROCEDURE FOR CORNEAL THERAPY THERAPY CONTRACT/STANDING ORDER BENEFITS WHAT IS CORNEAL THERAPY?

More information

Myopia Control Basics

Myopia Control Basics Basics Brooke Messer, OD, FAAO, FSLS Cornea and Contact Lens Institute of MN drbmesser@gmail.com Disclosures Alden Optical Residency Forum Coordinator B & L research funds CooperVision consultant Precilens

More information

Contact Lenses in 2020 and Beyond: What Does the Future for Contacts Look Like?

Contact Lenses in 2020 and Beyond: What Does the Future for Contacts Look Like? Lyndon Jones PhD, FCOptom, FAAO Financial Disclosures: Contact Lenses in 2020 and Beyond: What Does the Future for Contacts Look Like? Lyndon Jones PhD FCOptom FAAO Professor and University Research Chair

More information

Retinal Nerve Fiber Layer Measurements in Myopia Using Optical Coherence Tomography

Retinal Nerve Fiber Layer Measurements in Myopia Using Optical Coherence Tomography Original Article Philippine Journal of OPHTHALMOLOGY Retinal Nerve Fiber Layer Measurements in Myopia Using Optical Coherence Tomography Dennis L. del Rosario, MD and Mario M. Yatco, MD University of Santo

More information

Abdel Rahman ElSebaey, MD, PhD.

Abdel Rahman ElSebaey, MD, PhD. Surface Ablation Refractive Surgery Abdel Rahman ElSebaey, MD, PhD. Menoufia University History Correction of optical defects of human eye started 1200 AD. Spherical error corrected by spectacle on 13

More information

Analysis of eye movements during myopic laser in situ keratomileusis

Analysis of eye movements during myopic laser in situ keratomileusis 15th International SCHWIND User Meeting, Vancouver 2014 Analysis of eye movements during myopic laser in situ keratomileusis Thomas Kohnen Department of Ophthalmology Goethe-University, Frankfurt, Germany

More information

Strategies for Anterior Segment Disease Management Mile Brujic, OD, FAAO 1409 Kensington Blvd Bowling Green, OH

Strategies for Anterior Segment Disease Management Mile Brujic, OD, FAAO 1409 Kensington Blvd Bowling Green, OH Strategies for Anterior Segment Disease Management Mile Brujic, OD, FAAO 1409 Kensington Blvd Bowling Green, OH 43402 brujic@prodigy.net 419-261-9161 Summary As optometry s scope of practice continues

More information

SCLERAL CONTACT LENSES Fitting, Troubleshooting, and Future Advancements

SCLERAL CONTACT LENSES Fitting, Troubleshooting, and Future Advancements DISCLOSURES SCLERAL CONTACT Fitting, Troubleshooting, and Future Advancements Consultant Bausch + Lomb Allergan Scleral Lens Education Society Fellowship Chair Pam Satjawatcharaphong, OD, FAAO, FSLS Assistant

More information

What are some common conditions that affect the cornea?

What are some common conditions that affect the cornea? What are some common conditions that affect the cornea? Injuries After minor injuries or scratches, the cornea usually heals on its own. Deeper injuries can cause corneal scarring, resulting in a haze

More information

RECENT ADVANCES IN ANTERIOR SEGMENT IMAGING OF THE EYE. by Eszter Szalai, M.D. Supervisor: László Módis, M.D., Ph.D.

RECENT ADVANCES IN ANTERIOR SEGMENT IMAGING OF THE EYE. by Eszter Szalai, M.D. Supervisor: László Módis, M.D., Ph.D. SHORT THESIS FOR THE DEGREE OF DOCTOR OF PHILOSOPHY (Ph.D.) RECENT ADVANCES IN ANTERIOR SEGMENT IMAGING OF THE EYE by Eszter Szalai, M.D. Supervisor: László Módis, M.D., Ph.D. UNIVERSITY OF DEBRECEN DOCTORAL

More information

Corneal Topography / Computer- Assisted Corneal Topography/Photokeratoscopy

Corneal Topography / Computer- Assisted Corneal Topography/Photokeratoscopy Corneal Topography / Computer- Assisted Corneal Topography/Photokeratoscopy Policy Number: 9.03.05 Last Review: 10/2018 Origination: 10/2000 Next Review: 10/2019 Policy Blue Cross and Blue Shield of Kansas

More information

FUCH S DYSTROPHY & CATARACT SURGERY TREATMENT ALGORITHM

FUCH S DYSTROPHY & CATARACT SURGERY TREATMENT ALGORITHM FUCH S DYSTROPHY & CATARACT SURGERY TREATMENT ALGORITHM ΙΟΑΝΝΙS Α. MALLIAS, MD, PHD Director of the Dept. of Ophthalmology, Mediterraneo Hospital, Glyfada, Athens, Greece Clinical Fellow in Cornea and

More information

SCHWIND CAM Perfect Planning wide range of applications

SCHWIND CAM Perfect Planning wide range of applications SCHWIND CAM Perfect Planning wide range of applications ORK-CAM PresbyMAX PTK-CAM 2 SCHWIND CAM the system solution The modular design of the SCHWIND CAM offers customised treatment planning for a uniquely

More information

RETINAL NERVE FIBER LAYER

RETINAL NERVE FIBER LAYER CLINICAL SCIENCES The Effect of Scan Diameter on Retinal Nerve Fiber Layer Thickness Measurement Using Stratus Optic Coherence Tomography Giacomo Savini, MD; Piero Barboni, MD; Michele Carbonelli, MD;

More information

Keratoconus is a noninflammatory, ectatic corneal disorder. Scleral Lenses in the Management of Keratoconus ARTICLE

Keratoconus is a noninflammatory, ectatic corneal disorder. Scleral Lenses in the Management of Keratoconus ARTICLE ARTICLE Scleral Lenses in the Management of Keratoconus Muriel M. Schornack, O.D., and Sanjay V. Patel, M.D. Purpose: To describe the use of Jupiter scleral (Medlens Innovations, Front Royal, VA; and Essilor

More information

Interpretation of corneal tomography

Interpretation of corneal tomography Interpretation of corneal tomography Presented by Chameen Samarawickrama - Westmead Hospital - Liverpool Hospital - University of Sydney - University of New South Wales The University of Sydney Page 1

More information