Calibration at Testo Industrial Services
|
|
- Horatio Montgomery
- 5 years ago
- Views:
Transcription
1 Calibration at Testo Industrial Services Testo Industrial Services More assurance, better service.
2 Content Testo Industrial Services - Your calibration service provider Page 3 Page 6 Page 8 Page 10 Testo Industrial Services Your calibration service provider Electrical calibration laboratory Thermodynamical calibration laboratory Mechanical calibration laboratory Testo Industrial Services is a leading service provider company in the field of calibration, qualification, validation as well as test equipment management with more than 20 years of calibration experience and know-how. Testo Industrial Services started as a calibration department at Testo AG, the parent company, however was founded as an independent subsidiary in Driven by the requirements of our customer and our innovative ideas, we are permanently developing and improving the procedures of our company. We are accredited for more than 190 calibration procedures according to DIN EN /IEC Quality, reliability and low measurement uncertainties are the cornerstones of our work. Page 12 Calibration laboratory for flow rate With an average sales growth of nearly 20 %, Testo Industrial Services is one of the most successful calibration service Testo Industrial Services More assurance, better service. Page 14 Documentation of calibration providers in Germany and Europe. Page 16 Instrument management Page 19 Electrical parameters detailed overview Page 25 Thermodynamical parameters detailed overview Page 29 Page 31 Mechanical parameters detailed overview Scope of Accreditations - Raimund Föhrenbacher Managing Director Jürgen Hinn Managing Director Page 32 References Page 33 Contact addresses 2 3
3 More assurance, better service! Always close at hand Full services customized to meet your requirements Testo Industrial Services is a certified and accredited service provider. We offer a complete portfolio of services. Our aim is to meet your individual wishes and requirements. With a team of qualified, motivated and service-orientated employees, we are pleased to assist you in any issue as your calibration partner. Essential bases of our success are the qualification and personal responsibility of our employees. Our common, successful future were created with the high degree of self-motivation and cooperative teamwork. More than 680 employees are active for you throughout Europe. What characterizes us? We edit every order to your specific and individual requirements! With accredited calibration laboratories national Service-Center Winsen D-K Winsen Hannover Logistic-Center Hannover Service-Center Essen D-K Essen Service-Center Marburg Marburg Service-Center Rhein-Main-Neckar Customer-Center Abstatt Ludwigshafen Abstatt Logistic-Center Ingolstadt Kirchzarten Lenzkirch Ingolstadt Dingolfing München Customer-Center Dingolfing Service-Center München D-K Head Office/Service-Center Kirchzarten D-K Service-Center Lenzkirch D-K Customer-Center München... and International Accréditation N Temperature Accréditation N Accréditation N Hygrometrie 4 5
4 Electrical calibration laboratory Primary laboratory LF laboratory HF laboratory In our electrical primary laboratory, we calibrate high-quality standards in the electrical LF measuring technique. Our reference standards are calibrated directly at the national institutes (PTB, METAS) and are used for the traceability of your reference standards. Our measuring uncertainties are some of the smallest of all laboratories. In our LF laboratory we calibrate all standard measuring equipment with very small measuring uncertainties. For this purpose, we have various measuring stations with Fluke calibrators as references at our disposal. A HV measuring station completes the LF calibrations. In our accredited laboratories as well as on location, we calibrate HF devices up to 50 GHz. Furthermore, Testo Industrial Services has a special EMC measuring station. Automated procedures, experienced and qualified experts ensure a secure and accurate calibration of your devices. Calibration of measuring modules : ü Cleaning of contact surfaces according to the type of calibration device ü Visual inspection ü Inspection of the measuring devices according to TRBS ü Technical inspection of all electrical functions of the measuring devices ü Calibration certificate with set/actual values as well as measuring uncertainties ü Calibration label ü Repair and adjustment according to mutual agreement We calibrate various types of measuring modules and measuring cards of any manufacturer. You find an extract of our scope of service for electrical measurements on page
5 Thermodynamical calibration laboratory Temperature Surface temperature Humidity Select the appropriate calibration points for the operating range of your devices within the measuring range of -196 up to C. All electronic temperature measuring devices, resistance thermometers and thermal elements are calibra- Surface temperature probes, respectively sensors - either with contact or non-contact are calibrated at various measuring stations. The accredited calibration station for surface temperature sets new standards for the calibrati- In the humidity laboratory, the worldwide highest accuracies of 0,2 % can be achieved in our 2-pressure humidity generator. Measuring range from 5-95 %RH ( C). ted either in the salt bath, liquid bath or on of surface temperature probes. in the tube furnace with a natrium heat pipe. Primary laboratory temperature : ü Cleaning ü Visual inspection ü Technical inspection of all electrical functions ü Calibration certificate with set/actual values as well es measuring uncertainties ü Calibration label ü Repair, exchange and adjustment according to mutual agreement In our primary laboratory, we can calibrate devices with the smallest measuring uncertainties. At eight fixed points of the ITS-90, standard resistance thermometer and fixed point cells are calibrated. You find an extract of our scope of service for thermodynamical measurements on page
6 Mechanical calibration laboratory Pressure laboratory Torque measuring station Force measuring station One of the most accurate and reliable We can calibrate all common torque All common force devices and load cells industrial calibration methods is the wrenches, torque screw drivers and (in which the force is determined by pressure calibration with a pressure balan- torque sensors at our torque measuring the elastic deformation of a body) can ce. Therefore Testo Industrial Services use station. be calibrated at our calibration station. pressure balances of different types/model The measuring station has a measuring within the range of -1 up to 1100 bar as The measuring range of the force range up to 50 kn with a measuring reference standards. The entire measuring equipment is from 0,1 up to 1000 Nm uncertainty of 0, 1 %. range of our pressure laboratory is from with a measuring uncertainty of 0,5 %. -1 up to 5000 bar. Acceleration : ü Visual inspection ü Cleaning ü Technical inspection of the device functions ü Calibration certificate with set / actual values as well as measuring uncertainties ü Calibration label ü Repair, exchange and adjustment according to mutual agreement Monoaxial as well as triaxial acceleration sensors can be calibrated at our calibration equipment station in the range from 0, Hz. You find an extract of our scope of service for mechanical measurements on page
7 Flow rate calibrators Test bench laminar flow element Test bench critical nozzles Calibration laboratory for flow meters Four piston calibrators are installed for the calibration of your flow meter devices for liquids. The unique construction of the different calibrators enables measurements from different kind of liquids in a wide range from <0,8 ml/min up to l/min. The test bench enables the calibration of flow meters for air and inert gases. The capillaries inside the individual elements provide a laminar flow of an otherwise turbulent flow rate. The measuring range of the test bench A total of ten pneumatic actuated critical venturis are installed in the test bench for gas flow meters. Thereby the calibration is feasible in a wide range from very small flow rates (5 l/min)* up to very high flow rates Measured by a fluid pressure up to 12 bar and a standard temperature of approximately 20 C. extends about a flow rate from 1 ml/min 1000 l/min (Normal range). ( l/min)*. *Normal range Velocity/ Volume flow : ü Visual inspection ü Cleaning ü Technical inspection of the device functions ü Calibration certificate with set / actual values as well as measuring uncertainties ü Calibration label ü Repair, exchange and adjustment according to mutual agreement The velocity probes (various types) are calibrated in two special developed wind tunnels up to 68 m/s. Furthermore, volume flow devices can be calibrated up to 2000 m3/h. You find an extract of our scope of service for mechanical measurements on page
8 Documentation of calibration certificate or certificate? The result of a calibration and all essential information is documented in a calibration certificate. Basically one differentiates between certificates and certificates (Work certifcates). certificate (work certificate) Since 1987, the QS systems of industrial companies and meanwhile also the systems of service providers, banks, insurance companies, retailers, hospitals etc. are being certified. In addition, there are further branch-specific laws, standards and regulations in the pharmaceutical industry (CFR, GMP), in the food sector (HACCP), in the medical technology ( 13485) and in the automotive sector (VDA, QS9000, TS 16949). For all these regulations and standards, the calibration is absolutely essential. The certificates (work certificates) from Testo Industrial Services are the lowcost alternatives to the calibration certificates. They meet the requirements of: Kalibrier-Zertifikat Calibration certificate * Gegenstand Hiermit bestätigen wir, dass das durchführende Kalibrierlabor ein Managementsystem Temperaturmessgerät 11 Temperaturmessgerät 22 Object nach 9001:2008, sowie /IEC Hersteller 17025:2005 eingeführt hat. Die Urkunden Ahlborn Testo AGGmbH Ahlborn Testo AGGmbH finden Sie auf Die für die Kalibrierung verwen- Manufacturer deten Messeinrichtungen werden regelmäßig Typ Typ 100 Typ 200 kalibriert und sind rückführbar auf die nationalen Normale der Physikalisch Technischen Type description Bundesanstalt (PTB) Deutschlands oder auf Serien Nr andere nationale Normale. Wo keine nationalen Normale existieren, entspricht das Serial no. Messverfahren den derzeit gültigen technischen Regeln und Normen. Die für diesen Inventar Nr Inventory no. Vorgang angefertigte Dokumentation kann eingesehen werden. Alle erforderlichen Prüfmittel Nr. MPM7149 MPM7150 Messdaten sind auf der(n) nachfolgenden Test equipment no. Seite(n) dieses Kalibrier-Zertifikats aufgelistet. Equipment Nr Hereby we confirm that the performing Equipment no. calibration labratory is working with a management system according to 9001:2008 Standort and /IEC 17025:2005. Accreditation STANDORT 2177 STANDORT 2299 Location certificates can be found under The measuring installations used for calibration are regularly Debitor D Auftraggeber calibrated and traceable to the national Customer standards of the German Federal Physical DE Freiburg Technical Institute (PTB) or other national Kunden Nr. standards. Should no national standards exist, the measuring procedure corresponds Customer ID no. with the technical regulations and norms valid Auftrags Nr / at the time of the measurement. The documents established for this procedure are Order no. available for viewing. All the necessary measured data can be found on the following Datum der Kalibrierung page(s) of this calibration certificate. Date of calibration Datum der empfohlenen Rekalibrierung Date of the recommended re-calibration Konformitätsaussage conformity Messwert(e) innerhalb der zulässigen Abweichung¹. Measured value(s) within the allowable deviation¹. Messwert(e) außerhalb der zulässigen Abweichung¹. Measured value(s) outside of the allowable deviation¹. ¹) Die Messunsicherheit wurde nach GUM mit dem Erweiterungsfaktor k=2 berechnet und enthält die Unsicherheit des Verfahrens so wie die Unsicherheit des Prüflings. Die Konformitätsaussage erfolgte nach DIN EN gemäß der Kalibrieranweisung QSA ¹) The measurement uncertainty was calculated according to the regulations of GUM with the coverage factor k=2 and contains the uncertainty of the measuring procedure and the uncertainty of the measuring system. The statement of conformity was made according to DIN EN according to calibration instruction QSA Dieser Kalibrierschein darf nur vollständig weiterverbreitet werden. Auszüge oder Änderungen bedürfen der Genehmigung des ausstellenden Kalibrierlaboratoriums. Kalibrierscheine ohne Unterschrift und Stempel haben keine Gültigkeit. This calibration certificate may not be reproduced other than in full except with the permission of the issuing laboratory. Calibration certificates without signature and seal are not valid. 9001:2015 CFR VDA GMP 9001:2008 TS Stempel seal Fachverantwortlicher supervisor Bearbeiter technician Max Tim Tröndle Mustermann Max Olaf Andler Mustermann Fon Seite testo industrial services GmbH Gewerbestrasse 3, Kirchzarten Fax industrial-services@testo.de Page certifikate 1/2 certificate GmbH (Deutsche Akkreditierungsstelle /German Accreditation Body) is attesting that accredited calibration and test laboratories are calibrating according to EN /IEC The obtained measuring results in these laboratories have the highest level of reliability and are binding in court! Through international agreements and the world-wide valid accreditation DIN EN /IEC 17025, the calibrations are internationally recognized and valid. Muster For all users of measuring devices, which requires a high level of security, accuracy and reliability, the certificate is the perfect solution. Often calibrations are required in the following fields: Factory- and working standards Experts State agencis Test laboratories Max Mustermann Max Mustermann certificate In our information center at you can find sample certificates, accreditation certificates, certification our general terms and conditions etc
9 Instrument management PRIMAS Calibration and test equipment data via internet PRIMAS online allows you to access your calibration and test equipment data via the internet: regardless of location and time! At any time you can retrieve, modify or create data mobile via an internet browser. Each calibration certificate is available to you by default as a PDF file. PRIMAS ü online Screenshoot Overview of equipment Screenshoot Certificate download Screenshoot Search test equipment Features Create, modify and retrieve test equipment data Download of calibration certificates Evaluation of your test equipment including call-off lists and escalation scenarios Excel data-export Individual authorization concept Individual description Individual calibration date Statistics... And further functions Your advantages ü ü ü ü ü ü ü Easy and intuitive operation Access to your equipment data regardless of your location One price for any number of users Free of charge download of your calibration certificates Dynamic evaluation of your testing equipment including call-off lists and escalation scenarios No additional software installation required Highest safety (128-Bit encrypted) 16 17
10 Electrical parameters Scope of services LF (low frequency) Laboratory Analog meter/digital multimeter One range-analog meter, Multi range-analog meter VDC, VAC, ADC, AAC, Ohm VDC, VAC, ADC, AAC, Ohm VDI/VDE/DGQ/DKD guideline 2622 page 3 VDI/VDE/DGQ/DKD guideline 2622 page 3 Digital multimeter 3,5 up to 8,5 digit VDC, VAC, VDI/VDE/DGQ/DKD guideline 2622 page 3 VDC, VAC, ADC, AAC, Ohm, capacity, frequenzy, temperature VDI/VDE/DGQ/DKD guideline 2622 page 3 Oszilloscope 1 up to 4-channeloscilloscope specification of the VDI/VDE/DGQ/DKD guideline 2622 page 4 specification of the VDI/VDE/DGQ/DKD guideline 2622 page 4 Current clamp Current clamp up to 1000 A VDI/VDE/DGQ/DKD guideline 2622 page 15.4 up to 1000 A VDI/VDE/DGQ/DKD guideline 2622 page 15.4 Miscellaneoaus Earth wire test devices, isolations measuring devices specification of the specification of the VDI/VDE/DGQ/DKD guideline 2622 page 9.1 VDI/VDE/DGQ/DKD guideline 2622 Blatt 9.1 High tension test devices kv kv 18 19
11 Electrical parameters Miscellaneous Picoamperemeter, Nanovoltmeter, Electrometer, Picoampere Sourcen Line recorder, XY-recorder Power meter specification of the 1 pa A Comparison measurement with PTB/ calibrated 1 pa A Comparison measurement with PTB/ calibrated all physical. sizes VDI/VDE/DGQ/DKD guideline 2622 page 21 (Special features for certain recorder types on request) all physical. sizes VDI/VDE/DGQ/DKD guideline 2622 page 21 (Special features for certain recorder types on request) specification of the Power supply unit specification of the Primary Laboratory specification of the Comparison measurement with PTB/ calibrated Comparison measurement with PTB/ calibrated Comparison measurement with PTB/ calibrated Comparison measurement with PTB/ calibrated Elektrical Standards/References Standard resistors 100 µw up to 100 TW AC/DC-Standard Fluke 732 Fluke 7001 Fluke 792 Voltage ratio 350 W-D350 calibration device and the indicators Resistance ratio AC- and DC- resistor bridges 100 µw up to 100 TW DC 1 V... 1,018 V 10 V AC 1 mv V (10 Hz up to 1 MHz) DC 1 V... 1,018 V 10 V AC 1 mv V (10 Hz up to 1 MHz) 2/5/10 mv/v at 225/600/4800 Hz and 2,5/5 V 2/5/10 mv/v at 225/600/4800 Hz and 2,5/5 V 0,16 up to 6,27 (16 W up to 127 W) Electrical Standards/References Calibrators Fluke 5700/5720 Fluke 5500/5520 Fluke 5320, etc. Datron: 4800; 4808; 9100; 4707; 4200 (further calibrators - various manufacturers) VDC, VAC, ADC, AAC, Ohm, capacity, frequency, temperature VDC, VAC, ADC, AAC, Ohm, capacity, frequency, temperature Comparison measurement with PTB/ calibrated Comparison measurement with PTB/ calibrated Measuring resistors/shunt Resistors, Shunts 100 µw up to 100 TW VDI/VDE/DGQ/DKD guideline 2622 page 8 up to 100 A VDI/VDE/DGQ/DKD guideline 2622 page 8 Reference Mulitmeter Agilent HP3458 Fluke 8508A (further multimeter various manufacturers) VDC, VAC, ADC, AAC, Ohm, capacity, frequency, temperature VDC, VAC, ADC, AAC, Ohm, capacity, frequency, temperature Comparison measurement with PTB/ calibrated Comparison measurement with PTB/ calibrated Capacitance Measure capacitor 1 pf up to 1 µf 50 Hz up to 1 MHz 1 pf up to 1 µf 50 Hz up to 1 MHz 20 21
12 Electrical parameters Inductivity Inductivity 100 µh up to 10 H at 1 khz 100 µh up to 10 H at100 Hz/1 khz/ 10 khz reference and working reference and working HF (high frequency) laboratory Powersensors/ Powermeter HF-Laboratory Spectrum analyzer up to 50 GHz VDI/VDE/DGQ/DKD guideline 2622 page 11 Calibration Kits up to 50 GHz EMI Test Receiver bis 50 GHz DIN DIN up to 50 GHz VDI/VDE/DGQ/DKD guideline 2622 page 11 ESD-Pistols/ -generators DIN EN Network analyzer up to 50 GHz Comparison measurement up to 50 GHz VDI/VDE/DGQ/DKD guideline 2622 page 16 Coupling Clamps DIN EN Pulse generator up to 50 GHz VDI/VDE/DGQ/DKD guideline 2622 page 14.1 up to 50 GHz VDI/VDE/DGQ/DKD guideline 2622 page 14.1 Coupling networks DIN EN Network simulations calibration VDI/VDE/DGQ/DKD guideline 2622 page 15.1 Burst/Surge EFT/Power Fail DIN EN calibration DIN Absorber clamps DIN EN Damping members/ Attenuator up to 50 GHz up to 50 GHz Frequency Counter up to 50 GHz VDI/VDE/DGQ/DKD guideline 2622 page 7 RF amplifiers up to 50 GHz VDI/VDE/DGQ/DKD guideline 2622 page
13 Electrical parameters Thermodynamical parameters Measuring cards and measuring modules Temperature fixed points IPETRONIK-Module e.g. M-Serie/SIM-Serie Current, voltage, resistance and frequency by signal simulation Current, voltage, resistance and frequency by signal simulation Calibration at different ambient temperature (-40; +23; +85; +120 C) Calibration at different ambient temperature (-40; +23; +85; +120 C) Temperature fixed points cells, Resistance thermometer (SPRT) -189,3442 C -38,8344 C 0,010 C 29,7646 C 156,5985 C 231,928 C 419,527 C 660,323 C Argon melting point Mercury triple point Water triple point Gallium melting point Indium melting point Tin freezing point Zink freezing point Aluminium freezing point IMC-Module e.g.cronos/cansas HBM-Module e.g. MGCPlus/ QuantumX Temperature Air/immersion probe/ thermal element ( ) C DKD-R 5-1/DKD-R 5-3 ( ) C ETAS-Module e.g. ES610/ES620 Temperature data loggers ( ) C DKD-R 5-1/DKD-R 5-3 ( ) C Further modules e.g. CSM, Softing, AFT, Solartron, Caesar Saveris System ( ) C DKD-R 5-1/DKD-R 5-3 ( ) C NI-cards e.g. PXI, PCI, DAQ Fluid thermometers ( ) C Block calibrators ( ) C DKD-R 5-4! Please contact us, if you haven`t found your test equipment or you need an offer for a calibration. On the basis of the variety of measuring instruments it`s not possible to list all variations in this catalog. Please use our contact form on our website: ( ) C 24 25
14 Thermodynamical parameters Temperature/ surface temperature Stop watches Contact surface temperature probe copper: ( ) C aluminium: ( ) C steel: ( ) C Comparison measurement with reference thermal elements on different surfaces All types of watches/ clocks depending on the type depending on the type ( ) C Comparison measurement on a blank aluminium surface Infrared measuring instrument ( ) C Comparison measurement at the black body with emissivity ε=1 Luminosity_lux ( ) C Comparison measurement at the black body with emissivity ε=1 Thermal imager ( ) C Comparison measurement at the black body with emissivity ε=1 Lux-probes lx ( ) C Comparison measurement at the black body with emissivity ε=1 Humidity Electronic hygrometers Humidity data loggers, measuring transmitter, hygrometer without display, psychrometer Calibration range ( ) % rf Comparison measurement in the humidity generator/ climate chamber; Temperature range ( ) C ( ) % rf Comparison measurement in the humidity generator/ climate chamber; Temperature range ( ) C Analytics ph-measuring instruments LF-Meters 1; 3, 5; 15; 100; 700; 1413 µs or 100 ms 2; 4; 7; 9; 10; 11 ph Comparison measurement/ NIST traceable buffer solutions Comparison measurement/ NIST traceable conductivity solution Refractometer 0 and 15% brix According to manufacturer or customer requirements Sound pressure Hygrometers with direct measurement of dew point temperature (mirror dew point meter) ( ) C TP ( ) C TP Comparison measurement in the humidity generator/ climate chamber; Temperature range ( ) C Comparison measurement in the humidity generator/ climate chamber; Temperature range ( ) C Sound pressuremeasuring instruments, calibrators, microphone diameter 1 / / 2 ( mm) 94 db(a) at 31,5/63/125/250/ 500 Hz 1/2/4/8 khz 104 db(a) at 1kHz or 114 db(a) at 1kHz Comparison measurement with PTB/ calibrated reference and working standards Pressure dew point measuring instruments from Testo ( ) C TP Comparison measurement with calibrated reference and working standards 26 27
15 Thermodynamical parameters Mechanical parameters Flow rate devices Pressure Flow rate devices gas/air 1 ml/min up to ml/min 1 ml/min up to ml/min Calibration with air Calibration with air/ Calibration with gases Absolute pressure measuring instruments, differential pressure measuring dievices for pos. and neg. overpressure p e = bar p abs = 0, bar p e = bar p abs = 0, bar DKD-R 6-1 Flow rate liquid calibration 0,8 ml/min up to l/min Standard calibration/ Oil mixed calibrations/ UVC-Calibration 0,8 ml/min up to l/min Standard calibration/ Oil mixed calibrations/ UVC-Calibration Anemometer/ pitot tubes (0, ) m/s Comparison measurement with laser doubler anemometer, Speed of rotation (RPM) (0, ) m/s Comparison measurement in the wind tunnel Mechanical rpm measuring instruments rpm Volume flow measuring instruments ( ) m 3 /h blowing ( ) m 3 /h sucking ( ) m 3 /h blowing ( ) m 3 /h sucking Optical rpm measuring instruments rpm rpm rpm Force Force gauges, Hand force gauges, Dynamometer, force transducers, force measuring socket load cells in pulling and pressure directions 100 N - 20 kn DKD-R 3-3 up to 50 kn Acceleration Vibration sensors, Acceleration measuring instruments, accleration calibrators 0,2 Hz up to 10 khz DKD-R 3-1 0,2 Hz up to 20 khz DIN
16 Mechanical parameters Testo Industrial Services Torque/Rotation angle Scope of Accreditations Torque wrench/ torque screwdriver, torque transducers Nm right and left 0, Nm right and left DKD-R 3-8 DIN EN 6789 Torque sensors, Torque devices 0, Nm right and left Deutsche Akkreditierungsstelle GmbH Torque screw tool, torque sensors, torque screw tool with protactor 0 up to 360 Scope of Accreditation D-K to DIN EN /IEC 17025:2005 Period of validity: to Date of issue: Certificate bearer: testo industrial services GmbH Gewerbestraße Kirchzarten with the calibration laboratory: Scales/weights/weight sets testo industrial services GmbH Gewerbestraße Kirchzarten Scope of Accrediation D-K Spring scales, analytical scales, industrial scales, precision scales Pipettes Pipettes Fix, 1-channel var, 4-channel var, 8-channel var, 12-channel var up to 80 kg Comparison measurement Calibration onsite according to EURAMET up to 200 kg GxP Nominal volume > 10 µl Nominal volume > 10 µl DIN EN 8655 DIN EN 8655 Laboratory chief: Section leaders: Dipl.-Phys. Eugen Sander Falko Harich Christian Kliche Stefan Jurgeit Tim Tröndle Slade Hartwell Accredited calibration laboratory since: Areas of calibration: Electrical measurands Dimensional measurands DC and low frequency measurands Length Voltage *) - Gauge blocks - DC voltage *) - Length-measuring instruments - AC voltage *) - Diameter Current *) - Thread - Direct current *) Mechanical measurands - Alternating current *) - Force - AC/DC-Transfer - Weighing scales *) - Power - Pressure *) - Phase angle - Torque - DC resistance *) - Acceleration - Capacitance Volumetric flow rate measurands - Inductance - Flow speed of gases - Voltage ratio Thermodynamic measurands - High voltage measurands Temperature measurands High frequency measurands - Resistance thermometer *) - Impedance (Reflection coefficient) *) - Thermocouple *) - Power *) - Radiation thermometer - Attenuation *) - Temperature fixed-point cells - Oscilloscope measurands *) - Temperature dry-block calibrators *) - Rise time *) - Temperature indicators and simulators Time and frequency - Climate chambers (temperature) *) - Time interval *) - Temperature transmitter *) - Frequency *) and rotational speed Humidity measurands Page 1 of 58 - Measuring instruments for relative humidity - Climate chambers (humidity) *) *) In-Situ Calibration as well Definition of abbreviations used: see last page Hardness Shore hardness tester Shore A, Shore 00, Shore D Period of validity: to Date of issue: Page 2 of 58! Please contact us, if you haven`t found your test equipment or you need an offer for an calibration. On the basis of the variety of measuring instruments it`s not possible to list all variations in this catalog. Please use our contact form on our website: Convince yourself from our experience. See our accreditations: Direct to our accreditations: 30 31
17 References What can we do for you? You can count on the Team from Testo Industrial Services when assistance is required. We want to get to know you, your company, your specific requirements and tasks. Please contact us for any calibration issue. We would like to show you what Audi AG Onsite and lab calibration of all test equipments; test equipment management by PRIMAS exchange MAHLE Behr GmbH & Co. KG Calibration of electrical and physical test equipment at several locations including test equipment management BMW AG Onsite and lab calibration of test equipment from all kind of measuring parameters Hekatron Technik GmbH Onsite calibration of all measuring parameters; test equipment management by PRIMAS online KST Motorenversuch GmbH & Co. KG Calibration of engine testers maxon motor AG Onsite and lab calibration at different locations in Europe. Test equipment management by PRIMAS online. TÜV Süd Automotive GmbH Lab calibration of all parameters, management of logistics for calibration as well as test equipment management by PRIMAS online Webasto AG Onsite and lab calibration of all parameters and test equipments; test equipment management by PRIMAS exchange Weidmüller Interface GmbH & Co. KG Onsite calibration on various locations in Europe. Including automatical calibration data exchange via VDI/ VDE 2623 Testo Industrial Services can do for you! Testo Industrial Services GmbH Head Office/Service-Center Kirchzarten Gewerbestraße Kirchzarten Fon Fax info@testotis.de Subsidiaries Testo Industrial Services AG Gewerbestrasse 12a CH-8132 Egg Fon Fax Testo Industrial Services GmbH Geblergasse 94 AT-1170 Wien Fon Fax Robert Bosch GmbH Preferred Supplier of the Bosch Group Calibration of portable instruments for electrical parameters, entire test equipment management incl. calibration at different sites Conrad Electronic SE Lab calibration of all measuring parameters Miele & Cie. KG Calibration of electrical test benches onsite Schunk Ingenierkeramik GmbH Lab calibration of dimensional and mechanical measuring parameters; management of the logistics for calibration as well as test equipment management by PRIMAS online Vossloh Locomotives GmbH Lab calibration of all parameters, management of logistics for calibration as well as test equipment management by PRIMAS online Testo Industrial Services empresarial S.A.U. PI La Baileta C/ B, nº 5 ES Cabrils (Barcelona) Fon +34 (93) Fax +34 (93) Testo Industrial Services Sàrl Zone d activités Eurozone 3 rue Jules Verne F Forbach Fon Fax Dunkermotoren GmbH Onsite calibration of mechanical and electrical parameters; test equipment management by PRIMAS online Thales Deutschland GmbH Calibration of various radiocommunication testers GE Healthcare Europe GmbH Lab calibration of electrical, mechanical and thermodynamical measuring equipments as well as management of logistics for calibrations Trumpf Gruppe Onsite and lab calibration at various locations in Germany, including test equipment management by PRIMAS online 32 33
18 Testo Industrial Services GmbH Gewerbestraße Kirchzarten Fon Fax info@testotis.de Direct to
Calibration Flow meters for liquids and gases. Testo Industrial Services More assurance, better service.
Calibration Flow meters for liquids and gases Testo Industrial Services More assurance, better service. www.testotis.com Flow rate calibration Calibration of flow meters Due to the requirements of a constant
More informationCERTIFICATE OF CALIBRATION
CERTIFICATE OF CALIBRATION Aspartate aminotransferase (AST) Standardization laboratory Cert. 04-16 September 5 th, 2016 Measurement procedure: IFCC reference measurement procedure (Clin Chem Lab Med. 2002;40:
More informationTemperature. Pressure. Humidity. Consultation & Training Services. Electrical. Certus Metrology
Temperature Pressure Humidity Electrical Consultation & Training Services Certus Metrology CONTENTS Introduction...2 About the Director...3 Consultation and Training Service...4 Temperature Calibration
More informationWithdrawn at December 31, Guideline DKD-R 6-2. Calibration of Measuring Devices for Vacuum DEUTSCHER KALIBRIERDIENST. Part 1.
DEUTSCHER KALIBRIERDIENST Guideline DKD-R 6-2 Part 1 Calibration of Measuring Devices for Vacuum Fundamentals Edition 03/2002 Page 1 of 6 Published by the Accreditation Body of the Deutscher Kalibrierdienst
More informationA Guide for Choosing the Right Calibration for Torque Transducers
P1.9 A Guide for Choosing the Right Calibration for Torque Transducers Wegener, Georg / Stenner, Lioba Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45 64293 Darmstadt 1. Introduction Torque transducers
More informationTechnical Data Sheet SONOFLOW CO.55 V1.0
Technical Data Sheet SONOFLOW CO.55 V1.0 The sensor series SONOFLOW CO.55 V1.0 designed as clamp-on-sensors detect the flow rate of liquids in plastic tubes of different diameters or materials within a
More informationTEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP
TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED from a CURRENT LOOP P18L TYPE USER S MANUAL Contents 1. Application... 2 2. Basic requirements, operational safety... 2 3. Installation... 2 3.1. Assembly...
More informationSolutions at GE Inspection Technologies
Solutions at GE Inspection Technologies Business Overview Paul A. Meyer Our Company A global leader in technology-driven inspection solutions that deliver productivity, quality, and safety to our customers
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
oratory locations: 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Folgate House Folgate Road North Walsham Norfolk NR28 0AJ Contact: Mr P C A Marks Tel: +44 (0)1692 500555 Fax: +44 (0)1692
More informationTechnical Data Sheet SONOFLOW CO.55/xxx(H) V2.0
The sensor series SONOFLOW CO.55/xxx V2.0 designed as clamp-on-sensors detect the flow rate of liquids in plastic tubes of different diameters or materials within a few milliseconds. For applications on
More informationWe Provide Solutions for Electrical, Electronic,T&M,Process Instrumentation.We Are Authorised Regional Reprentavtive For
+91-8048764407 Optimum Electronic Instruments http://www.optimumelectronicinstruments.com/ We Provide Solutions for Electrical, Electronic,T&M,Process Instrumentation.We Are Authorised Regional Reprentavtive
More informationWith extended functionality the sensors are also applicable for the detection of air bubbles.
Technical Data Sheet The sensor series designed as clamp-on-sensors detect the flow rate of liquids in plastic tubes of different diameters or materials within a few milliseconds. With extended functionality
More informationMicroSwitcher TMS Series 6, 10, 15, 25 Watt
Features Ultraminiature AC/DC Switching Power Supply Modules Fully encapsulated Plastic Package Universal Input 85-264 VAC, 50/60 Hz High Efficiency Low Ripple and Noise Overload Protection EMI meets EN
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 NATIONAL CENTER FOR ANIMAL HEALTH CALIBRATION LABORATORY 1920 Dayton Avenue Ames, Iowa 50010 Dr. Karl Hochstein 515-337-7739 CALIBRATION Valid To: June 30,
More informationLMT-Goniophotometer GO-H 1400 Goniophotometer System for Measurement of Automotive Lamps
LMT-Goniophotometer GO-H 1400 Goniophotometer System for Measurement of Automotive Lamps Description and Technical Specification of the Equipment List of Contents: 0 Introduction...- 3-0.1 Principle...-
More informationCertificate of Accreditation to ISO/IEC 17025:2005
United States Department of Commerce National Institute of Standards and Technology Certificate of Accreditation to ISO/IEC 17025:2005 NVLAP LAB CODE: 200454-0 National Standards of Puerto Rico Rio Piedras,
More informationER75 Electro-Acoustic Ear Simulator. Operating Manual
ER75 Electro-Acoustic Ear Simulator Operating Manual ABOUT THIS MANUAL READ THIS OPERATING MANUAL BEFORE ATTEMPTING TO USE THE INSTRUMENT. Amplivox Ltd. 6 Oasis Park, Eynsham Oxfordshire, OX29 4TP United
More informationOIML R 122 Annex C RECOMMENDATION. Edition 1999 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION
INTERNATIONAL RECOMMENDATION OIML R 122 Annex C Edition 1999 (E) Equipment for speech audiometry Annex C Test report format Appareils pour l audiométrie vocale Annexe C Format du rapport d essai OIML R
More informationThe design and development of a force comparator standard machine to provide national traceability in force measurement to industry.
The design and development of a force comparator standard machine to provide national traceability in force measurement to industry. Speaker/ Author: S. Dlamini Co-author: C. Gouws National Metrology Institute
More informationTEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP
TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED from a CURRENT LOOP P18L TYPE USER S MANUAL 1 2 Contents 1. Application... 2 2. Basic requirements, operational safety... 2 3. Installation... 2 3.1. Assembly...
More informationPhysikalisch-Technische Bundesanstalt
Physikalisch-Technische Bundesanstalt Short Report for CCAUV, September2017 1. Organisation PTB is the National Metrology Institute of Germany and the highest technical authority for the field of metrology
More informationASSEMBLY AUTOMATION FOR PERFECT CANNUL A BONDING
ASSEMBLY AUTOMATION FOR PERFECT CANNUL A BONDING ENGINEERING ASSEMBLY AUTOMATION FEEDING TECHNOLOGY CANNULA BONDING MACHINES The qualification requirements to cannulas have reached a maximum level due
More informationHI Total Acidity Mini Titrator for Water Analysis
HI 84530 Total Acidity Mini Titrator for Water Analysis Piston Driven Pump with Dynamic Dosing The HI 84530 incorporates dynamic dosing to provide precison titrant delivery. Dynamic dosing adjusts the
More informationH Series Pneumatic Screwdrivers and Nutrunners. Products and Solutions for Assembly
H Series Pneumatic Screwdrivers and Nutrunners Products and Solutions for Assembly About We are personally committed to understanding and exceeding our customers requirements. We are committed to continuously
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60601-2-37 2001 AMENDMENT 1 2004-08 Amendment 1 Medical electrical equipment Part 2-37: Particular requirements for the safety of ultrasonic medical diagnostic and monitoring
More informationLexium 05 Servo Drives. Motion control The high concentrate solution for your machines
Lexium 05 Servo Drives Motion control The high concentrate solution for your machines Lexium 05 Servo Drives Leveraging ingenuity and intelligence for ease of use Top grade performance With this new generation
More informationCyBio Felix Your Automated Application Starts Here
Title Label Lab Automation CyBio Felix Your Automated Application Starts Here 2 CyBio FeliX Future-Proof Liquid Handling Automation Transform your manual workflows to automated processes on your benchtop!
More informationPrecise defect detection with sensor data fusion
Precise defect detection with sensor data fusion Composite Europe 2016 Dipl.-Ing. Philipp Nienheysen Laboratory for Machine Tools and Production Engineering (WZL) of RWTH Aachen University, Germany Chair
More informationRLS /E-EV MX SERIES
RLS 300 800/E-EV MX SERIES RLS/E-EV MX series burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier,
More informationPROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Data Sheet 10/63-6.47-EN Rev. C PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
More information4-20 ma Pressure Transducer
4-20 ma Pressure Transducer 56410099 Copyright 2017 Durham Geo Slope Indicator All Rights Reserved. This equipment should be installed, maintained, and operated by technically qualified personnel. Any
More informationRLS /M MX SERIES
The RLS/M MX series of burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above
More informationCerus P-Series General Specifications Section 15172
Cerus P-Series s Section 15172 Variable Frequency Drives PART 1-GENERAL 1.01 SECTION INCLUDES A. Variable Frequency Drive(VFD) 1.02 RELATED SECTIONS A. Section 16195 1.03 REFERENCES A. NEMA250 B. EN 50178
More informationThe Do s and Don ts of Pressure Transducers
The Do s and Don ts of Pressure Transducers ABSTRACT When specifying a pressure transducer for a process measurement, a number of items have to be considered. Some of the more important ones are discussed
More informationISO INTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 15197 First edition 2003-05-01 In vitro diagnostic test systems Requirements for blood-glucose monitoring systems for self-testing in managing diabetes mellitus Systèmes d'essais
More informationFCC Test Report (Part 1) RF Exposure (EMF)
FCC Test Report (Part 1) RF Exposure (EMF) Test Report no.: EMC_BO_002150 (v1.0) Date of Report: 02-FEB-2018 Number of pages: 14 Project support engineer: Frank Wittmann Test period: 16.01.2018-18.01.2018
More informationDescription. Modell-Nr Airless ProfessionalLine. According to ISO 1167 ASTM D 1598 ASTM D Simple and safe operation. Reliable test results
Modell-Nr. 1720 Airless ProfessionalLine According to ISO 1167 ASTM D 1598 ASTM D 1599 Description The internal pressure creep test is a test procedure for determining the strength of thermoplastic pipes.
More informationRLS /M MX SERIES
RLS/M burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above all, more flexible.
More informationHI Titratable Acidity Mini Titrator for Fruit Juice Analysis
HI 84532 Titratable Acidity Mini Titrator for Fruit Juice Analysis Piston Driven Pump with Dynamic Dosing The HI 84532 incorporates dynamic dosing to provide precison titrant delivery. Dynamic dosing adjusts
More informationTest-Report No.:
Date: 25-04-2016 Ear Plugs EN 352-2 Page 1 of 12 I. Device under test Test object: Universal ear plug Noizezz swim Trade name / Model reference: Noizezz sleep Noizezz fly State of construction: Production
More informationHI Titratable Acidity Mini Titrator for Fruit Juice Analysis
HI 84532 Titratable Acidity Mini Titrator for Fruit Juice Analysis Piston Driven Pump with Dynamic Dosing The HI 84532 incorporates dynamic dosing to provide precison titrant delivery. Dynamic dosing adjusts
More informationINSTRUMENTS. Personal alarm dosimeter 120 Survey meters 122 Beta secondary standard 123
INSTRUMENTS This section shows a range of state-of-the-art surface contamination monitors, survey dosimeters and personal alarm dosimeters from approved manufacturers. Personal alarm dosimeter 120 Survey
More informationNEW! KIBION DYNAMIC 13 C BREATH TEST ANALYSER. Rapid and reliable diagnosis of Helicobacter pylori infections
NEW! KIBION DYNAMIC 13 C BREATH TEST ANALYSER Rapid and reliable diagnosis of Helicobacter pylori infections Help prevent chronic Helicobacter pylori infections and the development of gastric cancer More
More informationGUIDANCE NOTE. Application of MEMS Ultrasonic Transducers to Flow Measurement.
GUIDANCE NOTE Application of MEMS Ultrasonic Transducers www.tuvnel.com Application of MEMS Ultrasonic Transducers Introduction This Guidance Note provides a review of the key issues associated with the
More informationRLS/E-EV MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES
The RLS/E-EV MX series of burners covers a firing range from 350 to 2400 kw, and they have been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil
More informationQuality assurance in medical device industry
LASERS & MATERIAL PROCESSING OPTICAL SYSTEMS INDUSTRIAL METROLOGY TRAFFIC SOLUTIONS DEFENSE & CIVIL SYSTEMS Quality assurance in medical device industry Solutions for medical products Jenoptik is increasingly
More informationcryoair freezing technology 1-Chamber System for Body Cryotherapy 85 C
cryoair freezing technology 1-Chamber System for Whole 85 C Body Cryotherapy Whole Body Cryotherapy MECOTEC Psychotherapy Atopic eczema Diseases of the joints and spine Rheumatic diseases Collagen diseases
More informationCompany Products Automation Service References. 1 Copyright SCHNUTZ GmbH
1 History Adding Value Certification Company We support our customers around the world as specialists of leveling machines and coil feeding lines. (Plant 1 Siegen) We are not only seeing ourselves as a
More informationSURETEST Torque Calibration System
SURETEST TM The SURETEST is a laboratory grade instrument which captures torque measurements with a user friendly interface. It features a large LCD graphical display. It may be used with a single transducer
More informationSetting big things into motion.
Setting big things into motion. Ergonomics Meets Control Technology INNOVATIVE Control Unit KST 19 ERGONOMIC UNIVERSAL Ergonomic Meets Control Technology Rotatable KST 19 Control Unit The rotatable KST
More informationDescriptions of NDT Projects Fall 2004 October 31, 2004
Descriptions of NDT Projects Fall 2004 October 31, 2004 Introduction There are two separate NDT labs in Magister: ULTRA for ultrasound and EDDY for eddy current. Both labs are equipped with mechanical
More informationDynamic Calibration of Pressure Transducers
Dynamic Calibration of Pressure Transducers 7 th Workshop on Analysis of Dynamic Measurements Paris, October 15-16, 2012 Edwin van de Bunt, Arthur Bouvy, MARIN Outline of the presentation Introduction
More information10 Years Experience in Industrial Phased Array Testing of Rolled Bars
18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa 10 Years Experience in Industrial Phased Array Testing of Rolled Bars Josef MAIER 1 and Gerhard Ferstl 1, 1 Böhler
More informationPHM-100 PORTABLE HANDHELD TRANSDUCER INDICATOR OPERATORS MANUAL. Transducer Techniques R
PHM-100 PORTABLE HANDHELD TRANSDUCER INDICATOR OPERATORS MANUAL Transducer Techniques R 42480 RIO NEDO, TEMECULA, CA 92590 (909) 719-3965 FAX (909) 719-3900 URL: http://www.ttloadcells.com E-mail: tti@ttloadcells.com
More informationMEGGITT SENSING SYSTEMS Endevco short course guide
MEGGITT SENSING SYSTEMS Endevco short course guide Shock and vibration measurement technology I Shock and vibration measurement technology II Instructors: Jon Wilson, Jon S. Wilson Consulting Michael Phan,
More informationUnderwater Acoustic Measurements in Megahertz Frequency Range.
Underwater Acoustic Measurements in Megahertz Frequency Range. Current State and Prospects of Development in Russia Alexander M. Enyakov,, Many medical applications of underwater acoustic measurements
More informationE SERIES. Contents CALIBRATION PROCEDURE. Version 2.0
CALIBRATION PROCEDURE E SERIES Version 2.0 Contents Introduction Document Scope... 2 Calibration Overview... 3 What Is Calibration?... 3 Why Calibrate?... 3 How Often Should You Calibrate?... 3 What Can
More informationmicroprocessor controlled eddy current brake Load / accuracy Watt, speed independent / according to DIN VDE
Technical data Ergometer for cardiac rehabilitation Brake system microprocessor controlled eddy current brake Load / accuracy 6-999 Watt, speed independent / according to DIN VDE 0750-238 Speed range 30-130
More informationFundamentals of Pressure Transducers
print close Fundamentals of Pressure Transducers (Unpublished) Hydraulics & Pneumatics Alan Hitchcox Tue, 2013 09 17 (All day) Pressure is a key factor in almost every fluid power circuit. Pressure transducers
More informationYY Translated English of Chinese Standard: YY PHARMACEUTICAL INDUSTRY STANDARD
Translated English of Chinese Standard: YY0766-2009 www.chinesestandard.net Sales@ChineseStandard.net PHARMACEUTICAL INDUSTRY STANDARD YY OF THE PEOPLE S REPUBLIC OF CHINA ICS 11.040.70 C 41 YY 0766-2009
More informationDefining Cutting Edge Quality. Laser Cutting Head BIMO-FSC BIMO-FSC
Defining Cutting Edge Quality Laser Cutting Head BIMO-FSC BIMO-FSC Modules 40 Laser light cable receiver Cover slide in front of collimation 9 46,5 0,2 86,5 64,4 2,5 131,2 Collimation module with manual
More informationImaging spot weld inspection using Phased Array technology new features and correlation to destructive testing
Imaging spot weld inspection using Phased Array technology new features and correlation to destructive testing Göran Vogt 1, Jens Mußmann 1, Benita Vogt 1 und Wilfried-Konrad Stiller 2 1 VOGT Ultrasonics
More informationDatasheet BR Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors
Datasheet BR Series /CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors NEW Compared to traditional fuse installation, the /CSA C22.2 No.5-02, UL1077/CSA
More informationWNK5 Series High Precision Pressure Transmitter
WNK5 Series High Precision Pressure Transmitter WNK5 series pressure transmitter is the high performance pressure transmitters provided by nhui WNK Electronic Engineering Co., Ltd. It transforms the physical
More informationRL/B MZ SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL RL 300/B MZ RL 400/B MZ. 600/ kw 1000/ kw
RL/B MZ series burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above all, more
More informationSURETEST Torque Calibration System
SURETEST Torque SURETEST TM The SURETEST is a laboratory grade instrument which captures torque measurements with a user friendly interface. It features a large LCD graphical display. It may be used with
More informationRLS/BP MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES. RLS 300/BP MX 600/ kw RLS 400/BP MX 800/ kw DUAL FUEL.
RLS/BP MX series burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above all,
More informationAMS 200. Goniophotometer for small to medium-sized lamps and modules
AMS 200 Goniophotometer for small to medium-sized lamps and modules 02 \\ Equipment and function Ke features at a glance CIE Tpe A goniometer for small to medium-sized lamps and modules High-precision
More informationLiquid level transmitter Type AKS 41 / 41U REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Liquid level transmitter Type AKS 41 / 41U REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3
More informationHI Total Alkalinity Mini Titrator for Water Analysis
HI 84531 Total Alkalinity Mini Titrator for Water Analysis Piston Driven Pump with Dynamic Dosing The HI 84531 incorporates dynamic dosing to provide precison titrant delivery. Dynamic dosing adjusts the
More informationELECTRONIC PIPETTE. The electronic pipette with guaranteed performance in both standard and repetitive pipetting. PRECISE EASY-TO-USE RELIABLE
ELECTRONIC PIPETTE The electronic pipette with guaranteed performance in both standard and repetitive pipetting. PRECISE EASY-TO-USE RELIABLE DELIVER ON-TARGET PERFORMANCE PIPETMAN M has been designed
More informationORTHOPHOS XG 3 DS. X-ray systems. ORTHOPHOS XG 3 Digital panoramic X-ray for practical diagnostics.
ORTHOPHOS XG 3 DS X-ray systems ORTHOPHOS XG 3 Digital panoramic X-ray for practical diagnostics. ORTHOPHOS XG 3 Standard panoramic X-ray with proven technology. competent successful Many years of competence
More informationDefining Cutting Edge Quality. Laser Cutting Head BIMO-FSC BIMO-FSC
Defining Cutting Edge Quality Laser Cutting Head BIMO-FSC BIMO-FSC Laser Cutting Head BIMO-FSC for Flexible Flat Sheet Cutting The use of fibre lasers for cutting applications is growing steadily. The
More informationIES LM Test Report
IES LM 79 08 Test Report Test results reported for: B 3 DL report: LEAG002 010 Original issue date: 01 May 2012 Prepared for: Testing performed by: The Leader Leader Mfg., Inc 1003 7th Ave. 1540 Leader
More informationLiquid ring vacuum pumps single-stage
Liquid ring vacuum pumps single-stage LOH 20103, LOH 20107 Pressure range: Suction volume flow: 150 to 1013 mbar 7 to 58 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring vacuum pumps are displacement pumps
More informationSelection and Optimization of the Sample Introduction System
Selection and Optimization of the Sample Introduction System Geoff Tyler*, Lisa Goldstone, Odile Hirsch* Jobin Yvon, Inc., 3880 Park Avenue, Edison, NJ 08820 * Jobin Yvon SAS, 16-18, rue du Canal, 91165
More informationWorkshop on Hadron Beam Therapy of Cancer Erice, Sicily April 24-May
IONTRIS Synchrotron based PT Solutions from Siemens AG Workshop on Hadron Beam Therapy of Cancer Erice, Sicily April 24-May 1 2009 Matthias Herforth VP Business Development and Communications Siemens AG
More informationHI Total Alkalinity Mini Titrator for Water Analysis
HI 84531 Total Alkalinity Mini Titrator for Water Analysis Piston Driven Pump with Dynamic Dosing The HI 84531 incorporates dynamic dosing to provide precison titrant delivery. Dynamic dosing adjusts the
More informationPage 1 of 7 Pages Weight ID Number 12345A Certificate Number SECTION 1: NAME AND ADDRESS OF CUSTOMER Date of Calibration 15-MAY-2018
P.O. Box 87 Thorofare, NJ 08086-0087 Phone: 856-686-1600 Fax: 856-686-1601 www.troemner.com e-mail: troemner@troemner.com Page 1 of 7 Pages SECTION 1: SECTION 2: APPROVED SIGNATORY Joseph Moran, Metrology
More informationOrthopaedic. solutions
Orthopaedic solutions Our mission from standard products to customized solutions, to be Your preferred partner in the DESIGN, DEVELOPMENT AND MANUFACTURING OF INNOVATIVE SURGICAL DEVICES Design control
More informationQuick Sealing with a Twist to Connect Actuation Method
- Finger tighten seals up to 689 bar (10,000 psi) for pneumatic and hydraulic testing - Safe and Reliable leak tight connections to male and female threads - Eliminate thread damage, sealant and wrenches
More informationAutomated ultrasonic testing of submerged-arc welded (SAW) pipes using phased-arrays
18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa Automated ultrasonic testing of submerged-arc welded (SAW) pipes using phased-arrays 1 Jörg Ininger, 1 Ulrich Semmler,
More informationPeople have Priority. Endodontics
People have Priority Endodontics Endodontics Company 4 5 Product overview of Entran, Endo Cursor, Endea, Endo NiTi 6 7 Entran 8 9 Endo Cursor 10 11 Endea, Endo NiTi 12 13 W&H Endodontics 3 W&H Dentalwerk
More informationHiFFUT A New Class of Transducer
HiFFUT A New Class of Transducer Project Meeting April 2017 Dr Andrew Feeney Study of the electro-mechanical behaviour of flexural ultrasonic transducers This work will help us to design HiFFUTs for particular
More informationACTIVITY SCANNER NEW. 3D Dental Scanner made in Germany.
ACTIVITY SCANNER 3D Dental Scanner made in Germany NEW ACTIVITY SOFTWARE OPTICAL DENTAL SCANNER ERGONOMIC PRECISION INNOVATION CRANIUM-BASED MEASUREMENT FAST KNOW HOW EASE OF USE OPEN INTERFACE www.smartoptics.de
More informationDräger Alcotest 3820 Alcohol Screening Device
Dräger Alcotest 3820 Alcohol Screening Device The breathalyser Dräger Alcotest 3820 offers responsible drivers a reliable way to test their breath alcohol and gives them the assurance of being legal to
More informationCOST, PROCESS & QUALITY IMPROVEMENT
COST, PROCESS & QUALITY IMPROVEMENT - Finger tighten seals up to 10,000 psi (689 bar) for pneumatic and hydraulic testing - Safe and Reliable leak tight connections to male and female threads - Eliminate
More informationTESTIA For INNOVATIVE Solutions
TESTIA For INNOVATIVE Solutions 6 th Symposium for NDT in Aerospace Opening new ways in ndt using OMA communication system with Smart NDT Tool, UT & ET equipment Enhanced NDT by collaboration between mobile
More informationÜBERCLEAN! Introducing the new STATMATIC PLUS.
ÜBERCLEAN! Introducing the new STATMATIC PLUS. Product Advantages Safe validated cleaning verified by microbiological testing done by an independent laboratory. Economical low purchasing and operating
More informationPreparation Instructions for the CAMLOG /CONELOG Implant System
J8000.0032 Rev.6 EN 06/2015 Preparation Instructions for the CAMLOG /CONELOG Implant System ENGLISH The following descriptions contain detailed instructions on cleaning, disinfection and sterilization
More informationAPPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS
APPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS Jeffrey P. Milligan, Daniel T. Peters, Structural Integrity Associates, Inc., USA Many advances in Non-Destructive Examination
More informationTHS74/75 Industrial Temperature & Humidity Transmitter. Operation Manual
THS74/75 Industrial Temperature & Humidity Transmitter Operation Manual 1. Features 2. Security considerations 3. Installation 4. Connection 5. Display and LED instruction 6. Software setting and calibration
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
17065:2012 to provide product conformity certification Unit 1 Pendle Place Skelmersdale West Lancashire WN8 9PN Contact: Mr Simon Barrowcliff Tel: +44 (0)1695 556666 Fax: +44 (0)1695 557077 E-Mail: Simon.Barrowcliff@element.com
More information+91-8048600703 Radent Engineering http://www.radentndt.com/ RADENT ENGINEERING is one of the leading and fastest growing NDT EQUIPMENT Manufacturer in India offering an extensive range of world class NDT
More informationPROFIBUS Products Overview P PROFIBUS Converter/Repeater P PROFIBUS Gateway P6-3-1
.1. Overview P-1-1.2. PROFIBUS Converter/Repeater P-2-1.3. PROFIBUS Gateway P-3-1.4. PROFIBUS Remote I/O Modules P-4-1.5. PROFIBUS I/O Unit P-5-1 Overview.1. Overview PROFIBUS (Process Field Bus) is a
More informationSWITCHGEAR PBD. fuse bases
SWITCHGEAR PBD fuse bases designed for distribution of electricity and protection of electrical equipment against short-circuits and overloads with industrial fuse links ENERGY SAFELY SWITCHED SWITCHGEAR
More informationSWITCHGEAR PBD. fuse bases
SWITCHGEAR PBD fuse bases designed for distribution of electricity and protection of electrical equipment against short-circuits and overloads with industrial fuse links ENERGY SAFELY SWITCHED SWITCHGEAR
More informationStrain Gage Measurements
Strain Gage Measurements Strain Gage Measurements Strain gauge measurements The electrical resistance strain gauge technique is based on measuring the variation in electrical resistance undergone by a
More informationResearch on Digital Testing System of Evaluating Characteristics for Ultrasonic Transducer
Sensors & Transducers 2014 by IFSA Publishing, S. L. http://www.sensorsportal.com Research on Digital Testing System of Evaluating Characteristics for Ultrasonic Transducer Qin Yin, * Liang Heng, Peng-Fei
More informationMeasures 100 ppm to 100% water content. Precision titrant delivery system. Anti-diffusion burette tip. Built-in stirrer
HI 903 Karl Fischer Volumetric Titrator Measures 100 ppm to 100% water content Precision titrant delivery system 40,000 step, piston dosing pump Accurate to 0.1% Delivers as little as 0.125 µl of titrant
More information