Digital Micromirror Device Reliability and Failure Mechanisms
|
|
- Charlene Gaines
- 5 years ago
- Views:
Transcription
1 Digital Micromirror Device Reliability and Failure Mechanisms Michael R. Douglass Distinguished Member of the Technical Staff Texas Instruments Plano, Texas TRC: Oct 25-27, 2004
2 DMD Reliability and Failure Mechanisms Topics Introduction FMEA approach -- Identify potential risks Verification and performance demonstration Research Opportunities Summary 12/15/2004 j://stdpres/template.pot Slide 2
3 DMD Mirror Bias and Reset Voltage Mirror Yoke and Hinges Address (Logic) Voltage Address Electrodes and Landing Surface SRAM 12/15/2004 j://stdpres/template.pot Slide 3
4 Two DMD Mirrors - Landed 12/15/2004 j://stdpres/template.pot Slide 4
5 Top down view of tilted mirrors 12/15/2004 j://stdpres/template.pot Slide 5
6 A Few Facts About DMD MEMS Technology Number of mirrors 480,000 to >2,000,000 Mechanical motion Makes discrete contacts or landings Lifetime up to 100,000 hrs Address voltage 3.3-volt CMOS technology Mechanical elements Aluminum Package (Type A) Optical, hermetic, welded lid Process Low temperature, sputter deposition, plasma etch (standard SC processes) 12/15/2004 j://stdpres/template.pot Slide 6
7 DLP Board Digital Light Processing Processor Memory Projection Lens DMD Shaping Lens Optics Color Filter Condensing Lens Light Source Screen 12/15/2004 j://stdpres/template.pot Slide 7
8 DLP Overview Since 1996, over 3 million DLP- based display products have been shipped by over 50 different manufacturers DLP Front Projection now account for more than 1 out of every 3 projectors sold DLP TVs now selling in more than 5800 stores with more than 50 models expected in 2004 DLP Cinema now over 220 screens in 20 countries Capacity again more than doubled in 2004 with addition of Amkor and Anam capabilities 12/15/2004 j://stdpres/template.pot Slide 8
9 DMD Reliability and Failure Mechanisms Failure Modes and Effects Analysis (FMEA) How can a DMD fail? What is the root mechanism? Assess risk to lifetime, failure rate What tests can highlight the mechanism? Can we accelerate the mechanism? 12/15/2004 j://stdpres/template.pot Slide 9
10 DMD Reliability and Failure Mechanisms DMD Superstructure Hinge fatigue (do hinges break?) Hinge memory (limited life?) Nonfunctional (stuck) mirrors Shock and vibration failure Fully Qualified CMOS 12/15/2004 j://stdpres/template.pot Slide 10
11 DMD Reliability Verification FMEA Item #1 -- Hinge Fatigue Purpose Test Conditions Result Equivalent Lifetime Hinge Fatigue 1:1 Duty Cycle Accelerated 65 C > 3.67 Trillion Cycles > 69,000 hours > 250,000 hours* * Business projector application (1-chip, 8-bit) Assuming 1000 hours per year years of useful life Note: No hinge wearout time identified to-date 12/15/2004 j://stdpres/template.pot Slide 11
12 DMD Reliability Verification FMEA Item #3 Non-functional Mirrors Springtip design helps overcome surface adhesion 3249-C /15/2004 j://stdpres/template.pot Slide 12
13 DMD Reliability Verification FMEA Item #4 Shock and Vibration Storage Life Cold/Hot Temperature Cycle Thermal Shock -55/100C, no power -55/125C, air-to-air, fine/gross leak -55/125C, liquid-to-liquid 1000 hours 1000 cycles 200 cycles, 1000 cycles Sequence 1 Sequence g Mechanical Shock, Y only Vibration, 20g, Hz Constant Acceleration, 10Kg, Y1 only Thermal Shock, -55/125C Temperature Cycles, -55/+125C Moisture Resistance 15 cycles 100 cycles 10 days 12/15/2004 j://stdpres/template.pot Slide 13
14 DMD Reliability and Failure Mechanisms DMD Superstructure Hinge fatigue Hinge memory Nonfunctional (stuck) mirrors Shock and vibration failure Fully Qualified CMOS 12/15/2004 j://stdpres/template.pot Slide 14
15 DMD Reliability and Failure Mechanisms Opportunities for MEMS Reliability Research Properties of thin-films Surface effects of micro-/nano-structures Low-cost, reliable packaging techniques 12/15/2004 j://stdpres/template.pot Slide 15
16 Summary of DMD Reliability Hinge Memory Lifetime > 100,000 hours at normal operating conditions Random Defects > 650,000 hour MTBF (<1500 FIT) Hinge Fatigue Lifetime >3.67 Trillion Cycles or >250,000 hours Environmentally robust 12/15/2004 j://stdpres/template.pot Slide 16
INTERFACING TO THE DIGITAL MICROMIRROR DEVICE FOR HOME ENTERTAINMENT APPLICATIONS. Travis W. Migl
Proceedings of IPACK 01: The Pacific Rim/ASME International Electronic Packaging Technical Conference and Exhibition July 8-13, 2001, Kauai, Hawaii, USA IPACK2001-15712 INTERFACING TO THE DIGITAL MICROMIRROR
More informationPCN Number: PCN Date: 05/28/2015 Title: Alternative plating, Type A
PCN Number: 20150512001 PCN Date: 05/28/2015 Title: Alternative plating, Type A DLP-PCN-team@list.ti.com Customer Contact: Dept: DLP QRA Change Type: Assembly Site Design Wafer Bump Site Assembly Process
More informationGR-765-CORE Single Fiber Single-Mode Optical Splices and Splicing Systems Contents. Contents. Telcordia GR-765-Documentation Information
Telcordia GR-765-Documentation Information Generic Requirements Notice of Disclaimer...................... iii.......................................... v List of Figures..........................................
More informationInfrastructure for Rapid Assessment of Reliability
Infrastructure for Rapid Assessment of Reliability Infrastructure and process improvements in the reliability testing of a high density microelectronic packaging technology Hannah Varner Draper Outline
More informationRobust Subthreshold Circuit Design to Manufacturing and Environmental Variability. Masanori Hashimoto a
10.1149/05201.1079ecst The Electrochemical Society Robust Subthreshold Circuit Design to Manufacturing and Environmental Variability Masanori Hashimoto a a Department of Information Systems Engineering,
More informationFailure Mechanisms and Risk on LEDs and LED Systems SMT
Failure Mechanisms and Risk on LEDs and LED Systems SMT 5.5. 07.05.2015 Zwolle Noerdlingen Stuttgart Dresden Bath Why is the life time limited? The LED chip has a proven life time of more than 50.000 hours
More informationGUIDANCE NOTE. Application of MEMS Ultrasonic Transducers to Flow Measurement.
GUIDANCE NOTE Application of MEMS Ultrasonic Transducers www.tuvnel.com Application of MEMS Ultrasonic Transducers Introduction This Guidance Note provides a review of the key issues associated with the
More informationEI2311 BIOMEDICAL INSTRUMENTATION
66 EI2311 BIOMEDICAL INSTRUMENTATION 1. What is meant by cell? UNIT I PHYSIOLOGY AND TRANSDUCERS The basic living unit of the body is cell. The function of organs and other structure of the body is understood
More informationLION. Application Note PRECISION. Linear Position Measurement with Eddy-Current Sensors. LA March, Applicable Equipment: Applications:
LION PRECISION Application Note LA02-0061 March, 2013 Linear Position Measurement with Eddy-Current Sensors Position, Displacement Applicable Equipment: Eddy-Current position measurement systems. Applications:
More informationTransitioning from the CS4362 to the CS4362A or CS4365
Transitioning from the CS to the CSA or CS. Introduction This application note describes how to transition easily to the CS or CSA from an existing design that uses the CS. The CSA was designed to give
More information1. EXECUTIVE SUMMARY 2. PRODUCT SUMMARY
1. EXECUTIVE SUMMARY Success or failure in the medical industry begins with a diagnosis. This fact is well known and revered by clinicians, therapists, and health care providers. However, despite this
More informationUV + PVD: PERFORMANCE AND DESIGN SOLUTIONS FOR THE AUTOMOTIVE INDUSTRY. Eileen M. Weber, Red Spot Paint and Varnish, Co., Inc.
UV + PVD: PERFORMANCE AND DESIGN SOLUTIONS FOR THE AUTOMOTIVE INDUSTRY Eileen M. Weber, Red Spot Paint and Varnish, Co., Inc. What Is PVD? Physical Vapor Deposition PVD is deposition of a metal onto a
More informationAA-M1C1. Audiometer. Space saving is achieved with a width of about 350 mm. Audiogram can be printed by built-in printer
Audiometer AA-MC Ideal for clinical practice in otolaryngology clinic Space saving is achieved with a width of about 350 mm Easy operation with touch panel Audiogram can be printed by built-in printer
More informationLIMITED-LIFE ITEMS ANALYSIS FOR THE GLAST Anti-Coincidence Detector (ACD)
CDR REVISION Page 1 of 10 LIMITED-LIFE S ANALYSIS FOR THE GLAST Anti-Coincidence Detector (ACD) LAT-TD-01123-01 ACD-RPT-000039 Revision - October 21, 2002 Goddard Space Flight Center Greenbelt, Maryland
More informationSupporting Information
Supporting Information S1. Experimental Section Growth of ZnO NW film on carbon fibers. Carbon fibers are used not only as the flexible soft substrate onto which a ZnO thin film is grown at high temperature
More informationMD10826_Körperfettwaage_manual_UK.fm Seite 1 Mittwoch, 26. Juli :10 14
MD10826_Körperfettwaage_manual_UK.fm Seite 1 Mittwoch, 26. Juli 2006 2:10 14 TABLE OF CONTENTS Safety instructions................................. 2 Overview of the appliance...........................
More informationSiS9255. Projected Capacitive. Touch-Screen Micro Processor. Data sheet. Rev. 1.2 August 18, 2015
SiS9255 Projected Capacitive Touch-Screen Micro Processor Data sheet Rev. 1.2 August 18, 2015 This specification is subject to change without notice. Silicon Integrated Systems Corporation assumes no responsibility
More informationSpecialist in motion. Handleiding. User Manual MicroFET 2
Specialist in motion Handleiding User Manual MicroFET 2 Contents 1 Introduction... 2 2 Testing Method... 3 3 Reproducibility... 4 4 MicroFET2 Features... 5 5 Units of measurement... 7 6 Battery... 8 7
More informationRADIATION MONITORING DEVICES R A D I A T I O N P R O T E C T I O N & B I O L O G Y - R H O D E S
RADIATION MONITORING DEVICES 10-526- 1 9 7 R A D I A T I O N P R O T E C T I O N & B I O L O G Y - R H O D E S DETECTION AND MEASUREMENT OF IONIZING RADIATION Dosimeter Dose-measuring device Two classifications:
More informationSpecification for white LED
Specification for white LED Ergon COB 2530 62W maximum power capability High brightness LED Dimension : 23.85 x 23.85 x 2.35 mm Precondition : JEDEC Level 2a Lead-free reflow soldering application RoHS
More informationTranscutaneous Electrical Nerve Stimulation Device GF-3 / GF-3T
Transcutaneous Electrical Nerve Stimulation Device GF-3 / GF-3T Operation Manual Read Before Using GF-3-INS-LAB-RevA08 TABLE OF CONTENTS INTRODUCTION TO TENS INDICATIONS AND CONTRAINDICATIONS WARNINGS
More informationMaximizing Machinery Reliability vibration awareness
Maximizing Machinery Reliability vibration awareness Vibration analysis is often the cornerstone of modern machinery reliability programs. In order for machinery reliability programs to be effective, it
More informationAPPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS
APPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS Jeffrey P. Milligan, Daniel T. Peters, Structural Integrity Associates, Inc., USA Many advances in Non-Destructive Examination
More informationANALOG FRONT-ENDDESIGN FOR ECG SYSTEMS USING DELTA-SIGMAADCS
AN ECG FRONT END PDF ANALOG FRONT-ENDDESIGN FOR ECG SYSTEMS USING DELTA-SIGMAADCS HM301D ECG ANALOG FRONT-END - ST.COM 1 / 5 2 / 5 3 / 5 an ecg front end pdf Electrocardiogram (ECG) system analog front-end(afe)
More informationMeasuring equipment for professionals. Manual. Handleiding MicroFET 2
Measuring equipment for professionals Manual Handleiding MicroFET 2 Contents 1 Introduction... 2 2 Testing Method... 3 3 Reproducibility... 4 4 MicroFET2 Features... 5 5 Units of measurement... 7 6 Batteries...
More informationNew Core Alignment Fusion Splicer FSM-50S
New Core Alignment Fusion Splicer FSM-50S Shigeru Saito, Katsumi Sasaki, Kenji Takahashi, Koji Ohzawa, Taku Otani and Srachate Chumpol For many years, most fiber optic splicing in the core and edges of
More informationMaintenance and Logistics Experience at Loma Linda Proton Treatment Facility
Maintenance and Logistics Experience at Loma Linda Proton Treatment Facility Baldev Patyal, Ph.D., Chief Medical Physicist Department of Radiation Medicine Outline Loma Linda Proton Treatment Facility
More informationGymna ShockMaster 500
Gymna ShockMaster 500 Treat under the best possible conditions Product data sheet User friendly Two output channels for simple and rapid switch between hand pieces Noiseless and vibration-free oil compressor,
More informationECG SENSOR ML84M USER S GUIDE. CENTRE FOR MICROCOMPUTER APPLICATIONS
ECG SENSOR ML84M USER S GUIDE CENTRE FOR MICROCOMPUTER APPLICATIONS http://www.cma-science.nl Short description The ECG sensor measures electrical potentials produced by the heart (Electro- cardiogram).
More informationThe Next Generation of Time Lapse Systems. Miri TL. time lapse incubator for IVF. Designed in Denmark. Made in the E.U.
The Next Generation of Time Lapse Systems. Miri TL time lapse incubator for IVF Designed in Denmark Made in the E.U. Medical Devices 1023 2 Miri TL An affordable time lapse incubation system for IVF The
More informationDirect Reading (Pocket) Dosimeter
Direct Reading (Pocket) Dosimeter What is a Pocket Dosimeter???? Direct Read Pocket Dosimeters are rugged, precision instruments about the size of a pocket fountain pen, which are used to measure accumulative
More informationBio Compatible Microsystem Packaging of VCSELaser for Implantable Devices
Bio Compatible Microsystem Packaging of VCSELaser for Implantable Devices Dr Alexander Steinecker, CSEM, Alpnach (CH) EPoSS Annual Forum, Torino (IT), 25.09.2014 Copyright 2014 CSEM Alexander Steinecker
More informationProceedings Thin Film PZT Acoustic Sensor for Fully Implantable Cochlear Implants
Proceedings Thin Film PZT Acoustic Sensor for Fully Implantable Cochlear Implants Bedirhan İlik 1,2, Aziz Koyuncuoğlu 2, Hasan Uluşan 1, Salar Chamanian 1, Dilek Işık 2, Özlem Şardan-Sukas 2 and Haluk
More informationKINGS COLLEGE OF ENGINEERING DEPARTMENT OF MECHANICAL ENGINEERING QUESTION BANK. Subject Name: ELECTRONICS AND MICRIPROCESSORS UNIT I
KINGS COLLEGE OF ENGINEERING DEPARTMENT OF MECHANICAL ENGINEERING QUESTION BANK Subject Name: ELECTRONICS AND MICRIPROCESSORS UNIT I Year/Sem:II / IV PART-A(2 MARKS) SEMICONDUCTORS AND RECTIFIERS 1. What
More informationContents.
Contents Using The Video Otoscope... 3 The Battery Operated LED Light Source... 4 Connecting the Video Otoscope... 5 Connect the LEMO Cable... 6 Wiring Diagram... 7 Specula Adapter... 8 Trouble Shooting
More informationWHITE PAPER. Efficient Measurement of Large Light Source Near-Field Color and Luminance Distributions for Optical Design and Simulation
Efficient Measurement of Large Light Source Near-Field Color and Luminance Distributions for Optical Design and Simulation Efficient Measurement of Large Light Source Near-Field Color and Luminance Distributions
More informationTG100 Implementation Guide - FTA
FTA In this section, we will talk about Fault Tree Analysis (FTA). What is a fault tree? It is a tool used to trace failure pathways back to the causes and contributing factors. A fault tree analysis starts
More informationCerus P-Series General Specifications Section 15172
Cerus P-Series s Section 15172 Variable Frequency Drives PART 1-GENERAL 1.01 SECTION INCLUDES A. Variable Frequency Drive(VFD) 1.02 RELATED SECTIONS A. Section 16195 1.03 REFERENCES A. NEMA250 B. EN 50178
More informationAn Edge-Device for Accurate Seizure Detection in the IoT
An Edge-Device for Accurate Seizure Detection in the IoT M. A. Sayeed 1, S. P. Mohanty 2, E. Kougianos 3, and H. Zaveri 4 University of North Texas, Denton, TX, USA. 1,2,3 Yale University, New Haven, CT,
More informationPdM-101: Introduction to Vibration and Detection Analysis
PdM-101: Introduction to Vibration and Detection Analysis Abstract Vibration analysis is often the cornerstone of modern machinery reliability programs. In order for machinery reliability programs to be
More informationSMART ACTIVE IMPLANTABLE MEDICAL DEVICES: A VISION FOR THE FUTURE
SMART ACTIVE IMPLANTABLE MEDICAL DEVICES: A VISION FOR THE FUTURE Alain Ripart Senior Scientific Advisor Sorin Group September 27, 2012 Personalized medicine delivered by implanted devices is exploding
More informationWhat is a stepper motor?
What is a stepper motor? 1. A stepper motor (or step motor) is a brushless, synchronous electric motor that can divide a full rotation into a large number of steps. The motor's position can be controlled
More informationANNEX III: MALE CONDOM INSPECTION, SAMPLING AND TESTING SPECIFICATIONS
ANNEX III: MALE CONDOM INSPECTION, SAMPLING AND TESTING SPECIFICATIONS Prior to shipment, each consignment of condoms will be sampled by an independent inspection company appointed by UNFPA at the factory
More informationProduct Specifications and Usage Information P4405, P4410, & P4420 Genesys 30 Dosimeter Holder System
DESCRIPTION The Thermo Genesys 30 Spectrophotometer (G30) is supplied with specially designed dosimeter holders to fit a variety of dosimeters, including the B3 DoseStix and B3 WINdose dosimeters. The
More informationEfficient Measurement of Large Light Source Near-field Color and Luminance Distributions for Optical Design and Simulation
Efficient Measurement of Large Light Source Near-field Color and Luminance Distributions for Optical Design and Simulation Hubert Kostal*, Douglas Kreysar, Ronald Rykowski Radiant Imaging, Inc., 22908
More informationNoninvasive Glucose Monitors to 2022
Noninvasive Glucose Monitors to 2022 Devices, Technologies, Players and Prospects Report Prospectus Greystone Research associates N o n i n v a s i v e G l u c o s e M o n i t o r s t o 2 0 2 2 Greystone
More informationOptical cochlear implant project
Optical cochlear implant project Dr.-Ing. Stefan Mohrdiek MNBS 2014 LAAS, Toulouse 21 & 22 October 2014 This project is supported by the EU Commission, the European Research Funding organization under
More informationSTANDARD OPERATING PROCEDURE: RIGAKU RU 300 XRD POWDER SAMPLES
STANDARD OPERATING PROCEDURE: RIGAKU RU 300 XRD POWDER SAMPLES Purpose of this instrument: The Rigaku RU 300 XRD is used for phase analysis of polycrystalline films, characterizing single crystal, and
More informationScienceDirect. Design and Fabrication of Fully Implantable MEMS Cochlea
Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 100 (2015 ) 1224 1231 5th DAAAM International Symposium on Intelligent Manufacturing and Automation, DAAAM 2014 Design and Fabrication
More informationwww.gnresound.com consumerhelp@gnresound.com ReSound North America 8001 Bloomington Freeway Bloomington, MN 55420 1.800.248.4327 Fax: 1.952.769.8001 ReSound Canada 303 Supertest Road Toronto, Ontario,
More informationRLS for ExoMars Andoni G. Moral (RLS PM) on behalf of the RLS team
RLS for ExoMars 2020 Andoni G. Moral (RLS PM) (moralia@inta.es) on behalf of the RLS team II Congreso Ingeniería Espacial 23/11/2017 1 RLS CONSORTIUM The Team 2 EXOMARS OBJECTIVES TECHNOLOGICAL DEMONSTRATION
More informationProject: Feedback Systems for Alternative Treatment of Obstructive Sleep Apnea
Project: Feedback Systems for Alternative Treatment of Obstructive Sleep Apnea Idea: Create auditory and visual feedback systems to relate the amount of force back to the person exerting the force Potential
More informationAIR COOLED CONDENSERS
AIR COOLED CONDENSERS SELECTION GUIDE Data Aire, Inc. 230 W. BlueRidge Ave. Orange, CA 92865 www.dataaire.com TABLE OF CONTENTS DARC - Standard outdoor condenser general description... 3 DARC LD - Low
More informationPuls 2.0 Radial Pulse Therapy
Radial Pulse Therapy the next generation Radial Pulse Therapy An Effective Alternative For Treating Chronic Soft Tissue Pain Principle of Radial Pulse Therapy enpuls & move The hand piece contains a projectile
More informationANNEX III: CONDOM TESTING SPECIFICATIONS
ANNEX III: CONDOM TESTING SPECIFICATIONS Prior to shipment, each consignment of condoms will be sampled by an independent inspection company appointed by UNFPA at the factory or manufacturer s warehouse,
More informationA hybrid approach for identification of root causes and reliability improvement of a die bonding process a case study
Reliability Engineering and System Safety 64 (1999) 43 48 A hybrid approach for identification of root causes and reliability improvement of a die bonding process a case study Han-Xiong Li a, *, Ming J.
More informationramé-hart Model 90 Goniometer / Tensiometer
World Leader in Surface Science Instruments Since 1961 www.ramehart.com ramé-hart shown with optional Fiber Optic Illuminator Upgrade ramé-hart ramé-hart is available in two variations: The Contact Angle
More informationCETR Adhesion Testing on Glass/Al Surface for Corning Inc.
CETR Adhesion Testing on Glass/Al Surface for Corning Inc. I. Introduction 1.1 Objective The goal of the study was to differentiate stiction from various glass composites and surface treatments using the
More informationDisclosures. Outline. Learning Objectives. Introduction. Introduction. Stereotactic Breast Biopsy vs Mammography: Image Quality and Dose.
Disclosures Stereotactic Biopsy vs Mammography: and Dose None Vikas Patel, PhD, DABR Upstate Medical Physics 2014 Annual Meeting The American Association of Physicists in Medicine Austin, TX Learning Objectives
More informationElectric Desk Adjustable
Electric Desk Adjustable Instructions / Manual / Maintenance SAFETY NOTICE Failure to comply with this instruction manual may result in injury or damage of the product. Please keep the product far away
More informationContents. Helpline No. UK/ North Ireland Rep. Ireland Web Support Model Number: 12005
Contents 1 02 03 04 06 07 11 12 13 15 17 18 19 19 Contents Welcome Safety Instructions Box Contents Notes on Measurements Getting Started Measuring Weight Saving Personal Data Measuring Body Fat, Water
More informationRDHA710FR10A1NK. Neutron and Total Ionizing Dose Test Report. October 2009
Neutron and Total Ionizing Dose Test Report International Rectifier currently does not have a DSCC approved Radiation Hardness Assurance Program for MIL-PRF-38534. 205 Crawford St, Leominster, Ma 01453
More informationTABLE OF CONTENTS 1.1. WARRANTY DAMAGED SHIPMENTS SERVICE INTRODUCTION UNPACKING AND INSTALLATION
TABLE OF CONTENTS EDITION 5 Section 1 - WARRANTY & SERVICE 1.1. WARRANTY 2 1.2. DAMAGED SHIPMENTS 2 1.3. SERVICE 2 Section 2 - INTRODUCTION 2.1. INTRODUCTION 3 Section 3 - GENERAL 3.1. UNPACKING AND INSTALLATION
More informationUSER MANUAL, VOL.2.0 T I S S U E P U L L E R T P
USER MANUAL, VOL.2.0 T I S S U E P U L L E R - 5 6 0 T P TISSUE PULLER - 560TP USER MANUAL 2 TISSUE PULLER MODEL 560TP TRADEMARKS Danish Myo Technology A/S reserves the right to alter specifications as
More informationActive Thermography Imaging - an Innovative Approach for NDT Inspection
Active Thermography Imaging - an Innovative Approach for NDT Inspection Opgal: Leader in Thermal Imaging Non Destructive Tests Aviation Defense Industrial Security & Safety Mobile 30 Years of Infrared
More informationCompressor Nebulizer. Guidebook
NSTRU Compressor Nebulizer Guidebook MODEL: MQ6002 READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USE Compressor Nebulizer MODEL NO: MQ6002 INSTRUCTIONS INDEX 1. Introduction ----------------------------------------------------------------
More informationAdjust the chair height so that your feet rest comfortably on the floor, footrest or foot ring.
Laboratory ergonomics Some tasks performed in research laboratories can lead to joint and muscle strains if done for prolonged periods. The following tips can help you to work effectively and reduce fatigue
More informationIntroduction to Nondestructive Testing
Introduction to Nondestructive Testing Outline Introduction to NDT Overview of Six Most Common NDT Methods Selected Applications Definition of NDT The use of noninvasive techniques to determine the integrity
More informationAVR Based Gesture Vocalizer Using Speech Synthesizer IC
AVR Based Gesture Vocalizer Using Speech Synthesizer IC Mr.M.V.N.R.P.kumar 1, Mr.Ashutosh Kumar 2, Ms. S.B.Arawandekar 3, Mr.A. A. Bhosale 4, Mr. R. L. Bhosale 5 Dept. Of E&TC, L.N.B.C.I.E.T. Raigaon,
More informationHemodynamic Analysis System
Hemodynamic Analysis System Advisor: Professor Mitch Tyler Client: Professor Naomi Chesler Team members: Sarah Czaplewski, Megan Jones, Sara Schmitz, and William Zuleger Overview Pulmonary Hypertension
More informationSUPPLEMENTARY INFORMATION
Supporting Online Material High resolution electroluminescent imaging of pressure distribution using a piezoelectric nanowire-led array Caofeng Pan 1,2, Lin Dong 1,2, Guang Zhu 1, Simiao Niu 1, Ruomeng
More informationBody Fat Scales. instruction manual. with body analysis functionality. Model Number BF801-BK SL/BL
Body Fat Scales with body analysis functionality Model Number BF801-BK SL/BL instruction manual After Sales Support 07/04/2011 Contents Page 1 Introduction 3 2 General Information and Safety Instructions
More informationAlgorithms for Design-Automation - Mastering Nanoelectronic Systems Logic Diagnosis with improved resolution
Algorithms for Design-Automation - Mastering Nanoelectronic Systems Presenter: Alejandro Cook Slide 2 Overview Logic diagnosis DIAGNOSIX: A diagnosis methodology Discussion Summary Logic Diagnosis Slide
More informationECG MACHINE KEC- Series
KIZLON ECG MACHINE KEC- Series 404 Crescent Royale, Off New Link Road Andheri West, Mumbai 40053, Phones: 022-6708747 Email: info@kizlon.com Website: www.kizlon.com ECG Machine KEC-A100 This ECG machine
More informationS201-Z2. Miniature Circuit Breaker - S200-1P - Z - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions.
ABB Miniature Circuit Breaker - S200-1P - Z - 2 ampere General Information Extended Product Type Product ID S201-Z2 2CDS251001R0278 EAN 40167795054 Catalog Description Long Description Miniature Circuit
More informationFlexiSafe MLCC Termination Device Performance
FlexiSafe MLCC Termination Device Performance AVX Ltd. Jonathan Lennox Bally Castle Road Coleraine, Northern Ireland BT52 2DA AVX Ron Demcko 3900 Electronics Drive Raleigh, N.C. 27064 The MLCC advantages
More informationCompany Presentation 2016
Company Presentation 2016 Who We Are Alpha-Bio Tec. is a leading global provider of innovative dental implants, advanced prosthetics & surgical solutions Dedicated to making implantology simple, the company
More informationLED light engines LED linear / area. Module ELA G1 SNC Modules ELA ESSENCE
Module ELA G1 SNC Modules ELA ESSENCE Product description Edgelit panel for direct recessed mount and surface or suspended mount with accessories Two luminous flux range variants 2,8 or 3,8 lm For suspended
More informationWe are providing Level I, II Training and Certification as per Recommended practice SNT TC 1A 2006 in the following NDT Methods.
INTRODUCTION: Metal lab is built on strong Material Testing & Non - Destructive Testing, NDT Training & certification Courses expertise, founded in 2004 by group of professionals to serve the industry.
More informationWhite Paper. High performance resistors are key to meeting the demanding requirements of portable medical electronics designs. Issued in June 2014
White Paper High performance resistors are key to meeting the demanding requirements of portable medical electronics designs Issued in June 2014 The contents of this White Paper are protected by copyright
More informationWhat We Do To Reduce Work-related Musculoskeletal Disorders and Injuries at Occupational Ergonomics and Biomechanics (OEB) Laboratory
What We Do To Reduce Work-related Musculoskeletal Disorders and Injuries at Occupational Ergonomics and Biomechanics (OEB) Laboratory Jay Kim, PhD, MS Assistant Professor Environmental & Occupational Health
More informationPdM-202: Vibration Analysis Level II Plus TM
PdM-202: Vibration Analysis Level II Plus TM Abstract A primary goal of modern condition-based maintenance programs is to maximize machinery reliability. The success of these efforts is often monitored
More informationE2 Programming Start Up Guide for the M400 drive.
E2 Programming Start Up Guide for the M400 drive. 6 Necessary Applications Condenser M400 Drive VFD Status VFD Control Reset VFD Health VFD PCT HZ Added Application to Reduce Energy and Increase Life Cycle
More informationRESINOMER Dual- Bisco. Instructions for Use. Cured Amalgam Bonding/Luting System
Bisco RESINOMER Dual- Cured Amalgam Bonding/Luting System 0459 Instructions for Use IN-029R9 Rev. 10/17 BISCO, Inc. 1100 W. Irving Park Road Schaumburg, IL 60193 U.S.A. 1-847-534-6000 1-800-247-3368 Caution:
More informationThe Phalanx. Featuring Evolv DNA250 Technology. ***Keep Out of reach of children. This device is for persons 18yrs of age or older ***
The Phalanx Featuring Evolv DNA250 Technology ***Keep Out of reach of children. This device is for persons 18yrs of age or older *** Congratulations on your purchase of the Phalanx DNA250 temperature protected
More informationCAD/CAM TECHNOLOGY. DC7 Milling System
CAD/CAM TECHNOLOGY DC7 Milling System STRONG - PRODUCTIVE - MODERN The DC7 is a CAD/CAM machining centre for dental laboratories with industrial aspirations and desiring more efficient production. Wrapped
More informationSt. Jude Medical 8-Channel Adapter. Clinician's Manual
St. Jude Medical 8-Channel Adapter Clinician's Manual CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician. For U.S. California Only: Proposition 65, a State of California
More informationCompressor Nebulizer. Guidebook
NSTRU Compressor Nebulizer Guidebook MODEL: CN02WS (MQ6003) READ ALL INSTRUCTION BEFORE USE Airial TM Compressor Nebulizer INSTRUCTIONS INDEX 1. Introduction ----------------------------------------------------------------
More informationVerilog-AMS-PAM: Verilog-AMS integrated with Parasitic-Aware Metamodels for Ultra-Fast and Layout-Accurate Mixed- Signal Design Exploration
Verilog-AMS-PAM: Verilog-AMS integrated with Parasitic-Aware Metamodels for Ultra-Fast and Layout-Accurate Mixed- Signal Design Exploration G. Zheng 1, S. P. Mohanty 2, E. Kougianos 3, and O. Garitselov
More informationEffective Treatment for Obstructive Sleep Apnoea
Effective Treatment for Obstructive Sleep Apnoea The Series of Positive Airway Pressure devices from DeVilbiss Healthcare is designed to meet the varied needs of people suffering from Obstructive Sleep
More informationMiniature Circuit Breaker - S200-1P - B - 2 ampere. acc. to IEC / 400 V AC acc. to IEC V AC
ABB Miniature Circuit Breaker - S200-1P - B - 2 ampere General Information Extended Product Type S201-B2 Product ID 2CDS251001R0025 EAN 4016779612944 Catalog Description Miniature Circuit Breaker - S200-1P
More informationShockwave Therapy. Also referred to as Extracorporeal Shockwave Therapy
Shockwave Therapy Also referred to as Extracorporeal Shockwave Therapy TensCare Shockwave Therapy Unit Introduction ESWT Extracorporeal Shockwave Therapy is a non-invasive therapy that uses acoustic waves
More informationHX8801 Data Sheet TFT-LCD AV CONTROLLER
Data Sheet August, 2002 1F, No.12, Nanke 8 th Road, Tainan Science-Based Industrial Park, Tainan County, Taiwan 741, R.O.C. TEL: 886-6-505-0880 FAX: 886-6-505-0891 DOC No:HX8801-17 August 2002, 1. General
More informationA hybrid concept as a new approach for the micro-production of magnetic actuators
1 A hybrid concept as a new approach for the micro-production of magnetic actuators Rissing, L. H. H.; Creutzburg, T.; Steffens, M.; Reuter, G.; Lenarz, T. ABSTRACT Actuators that are widely used in industrial
More informationRail CRC Project R3-105
What is a squat? Squats are surface (or near-surface) initiated rolling contact fatigue (RCF) defects. They have also been called dark spots. Typically a crack starts to grow in the direction of travel
More informationCANADA SENSORS TECHNOLOGY INC.
CANADA SENSORS TECHNOLOGY INC. Manufacturer of Advanced Technology Pressure & Level Transmitters PRESSURE TRANSMITTER PROCESS 1 HART Enabled Intrinsically Safe Model Canada Sensors intelligent transmitters
More informationS201-C2. Miniature Circuit Breaker - S200-1P - C - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions.
ABB Miniature Circuit Breaker - S200-1P - C - 2 ampere General Information Extended Product Type Product ID 2CDS251001R0024 EAN 40167795225 Catalog Description Long Description Miniature Circuit Breaker
More informationfor Heart-Health Scanning
Magnetocardiography for Heart-Health Scanning CardioMag Imaging, Inc. 1 Basic Principles of Magnetocardiography (MCG) The cardiac electric activity that produces a voltage difference on the body surface
More informationProVari Owner s Manual
ProVari Owner s Manual Thank you for purchasing a ProVari Electronic Cigarette! Please read this manual before using your e cigarette. www.provape.com 1 An electronic cigarette, otherwise known as a personal
More informationImaging spot weld inspection using Phased Array technology new features and correlation to destructive testing
Imaging spot weld inspection using Phased Array technology new features and correlation to destructive testing Göran Vogt 1, Jens Mußmann 1, Benita Vogt 1 und Wilfried-Konrad Stiller 2 1 VOGT Ultrasonics
More information