Pulmonary Nodules: Contrast- Enhanced Volumetric Variation at Different CT Scan Delays

Size: px
Start display at page:

Download "Pulmonary Nodules: Contrast- Enhanced Volumetric Variation at Different CT Scan Delays"

Transcription

1 Cardiopulmonary Imaging Original Research Rampinelli et al. Contrast-Enhanced CT of Pulmonary Nodules Cardiopulmonary Imaging Original Research Cristiano Rampinelli 1 Sara Raimondi 2 Mauro Padrenostro 3 Elvio De Fiori 1 Stefano Meroni 3 Giulia Veronesi 4 Massimo Bellomi 1,3 Rampinelli C, Raimondi S, Padrenostro M, et al. Keywords: contrast material, CT, CT scan delay, pulmonary nodule, volumetric analysis DOI: /AJR Received June 19, 2009; accepted after revision January 5, Department of Radiology, European Institute of Oncology, Via Ripamonti 435, Milan 20141, Italy. Address correspondence to C. Rampinelli (cristiano.rampinelli@ieo.it). 2 Department of Epidemiology and Biostatistics, European Institute of Oncology, Milan, Italy. 3 School of Medicine, University of Milan, Milan, Italy. 4 Department of Thoracic Surgery, European Institute of Oncology, Milan, Italy. AJR 2010; 195: X/10/ American Roentgen Ray Society Pulmonary Nodules: Contrast- Enhanced Volumetric Variation at Different CT Scan Delays OBJECTIVE. The purpose of this study was to assess the effects of IV contrast medium and different CT scan delays on volumetric measurements of pulmonary nodule. MATERIALS AND METHODS. Automated volumes of 35 pulmonary nodules were calculated with two dedicated software packages (designated as software A and software B) for each unenhanced and contrast-enhanced CT scan at 30-, 60-, 120-, 180-, and 300-second delays (injection protocol, 2 ml/s and 2 ml/kg). Nodule attenuation was also determined. Differences between unenhanced and contrast-enhanced volumes were analyzed by Wilcoxon s signed rank test. Contrast-enhanced volume ratio was calculated as the ratio between contrast-enhanced and unenhanced nodule volume. RESULTS. Contrast-enhanced volumes were significantly larger than unenhanced volumes (p < 0.05) for all the timing delays except at 30 seconds for software A, and no significant differences were found among volumes measured with both software programs at different contrastenhanced delays. Median volume ratios between contrast-enhanced and unenhanced volumes were for software A and for software B, and median volume ratios within different contrast-enhanced delays were for software A and for software B. We did not find any significant association between contrast-enhanced volume ratio and nodule diameter, site, shape, unenhanced density, or contrast-enhanced density ratio (p > 0.05). CONCLUSION. We recommend comparing volume of pulmonary nodules obtained from CT examinations only if they are all performed with or without contrast material, whereas nodule volumes obtained by use of enhanced CT performed with different scan delays are comparable. C T follow-up of lung nodules is commonly used to assess potential growth of undetermined lesions and to evaluate therapeutic response of pulmonary metastases. To reduce intra- and interobserver variability of manual measurements [1, 2], some authors [3, 4] recommend automated volume calculation as a reliable tool to evaluate potential nodule variation that, in clinical practice, could drastically influence the diagnosis and eventual therapeutic choices. The accuracy of such a method is therefore crucial. Besides the physiologic and pathologic conditions [5 8] as well as the intrinsic nodule characteristics [6, 9], there are many scanning and reconstruction parameters affecting the calculation of automated volume, such as section thickness, algorithm, and reconstruction interval [10, 11]. The effect of contrast medium administration on volumetric analysis has been less in- vestigated; to our knowledge, only one other study has evaluated lung nodule volume variability before and after contrast medium injection [12], but none has determined the influence of different CT scan delays on volumetric variation. Even though iodinated contrast medium injection is mandatory for several CT examinations, in clinical practice we sometimes compare CT examinations performed with and without contrast medium or CT examinations with different timing delays even if the same CT protocol is being adopted; such conditions could affect the accuracy of automated volume calculation. As an example, lung nodules may be initially detected on CT examinations performed without contrast medium, but followup CT studies might require contrast medium. Moreover, a nodule could be discovered on survey CT of the chest and abdomen using triple-phase scan delays, and the patient might come back a few months later for a dedicated chest CT scan using different scan delays. AJR:195, July

2 Rampinelli et al. Fig year-old woman with right lower lobe pulmonary nodule. Image shows lung nodule volume (cubic millimeters) and density (Hounsfield units) of unenhanced (0 second) and contrast-enhanced CT scans performed at 30, 60, 120, 180, and 300 seconds, calculated with LungCARE software (Siemens Healthcare). In this study, we evaluated the variation of automated volume measurements of lung nodules during dynamic multiphase contrast-enhanced CT, using two different commercially available software packages. Thus, the aim of this study was to assess the effects of IV contrast material and different CT scan delays on automated volume measurement of pulmonary nodules and to determinate whether different software packages provide different contrast-enhanced measurements. Materials and Methods Data Source All data used in this retrospective study were collected from a previous research protocol aimed at diagnosing the nature of undetermined pulmonary nodules and small mass lesions by dynamic contrast enhancement study. In the previous research protocol, which was conducted from December 2004 to October 2006, 78 patients (57 men and 21 women; mean age, 64 years; range, years) with single undetermined solid pulmonary nodule 8 mm detected in a lung cancer screening program underwent dynamic contrast-enhanced chest CT. Our institutional review board approved the research protocol for this study, and written informed consent was provided by all patients. Examinations were performed using a 16-MDCT system (LightSpeed 16, GE Healthcare). Before starting CT, patients were asked to repeat the same breath-hold to reduce significant respiratory excursions. To localize the nodule, a whole-chest low-dose CT scan was performed (140 kvp; 30 ma; tube rotation, 0.8 second; pitch, 1.75; slice thickness, 2.5 mm; standard reconstruction algorithm). The acquisition field of view (FOV) ranged from 320 to 370 mm, depending on the patient s body habitus. Once the nodule was identified, we performed an unenhanced targeted FOV thin-section CT scan (120 kvp; automatic tube current modulation range, ma; pitch, 0.938; slice thickness, mm; standard reconstruction algorithm; FOV, 200 mm) through the nodule, for 50 mm along the z-axis. Nodules were excluded if they had calcification (four nodules), cavities (one nodule), or fat (three nodules) at thin-section CT. Thus, of the 78 enrolled patients, lung nodule enhancement was performed for 70 patients with a single nodule. After the administration of contrast medium, five dynamic thin-section CT scans with the same unenhanced thin-section CT parameters were performed at 30, 60, 120, 180, and 300 seconds. Iodinated nonionic contrast medium (iobitridol, 350 mg I/mL [Xenetix, Guerbet]) was administered IV at a rate of 2 ml/s (dose, 2 ml/kg of body weight) using a power injector (Stellant, Medrad). Present Study Nodule selection and CT images analysis From May 2008 through August 2009, all CT images obtained for the 70 patients for whom lung nodule enhancement was performed were retrospectively analyzed by two radiologists (with 8 and 3 years of experience in CT) using two different commercially available software packages dedicated to volume analysis: software A (ALA Single, GE Healthcare) and software B (Lung- CARE, Siemens Healthcare). Lung nodule volume and attenuation were calculated for each unenhanced and contrast-enhanced scan (Fig. 1). In the first session, all anonymized CT data sets were transferred to a workstation (Advantage 4.2, GE Healthcare). Of 70 pulmonary nodules evaluated, 26 nodules with visible pleural or vessel attachment were excluded from the study. The maximum transverse axial nodule diameter measured with an electronic caliper at unenhanced CT scan, the site (lobe), and the shape (round, irregular, or polygonal) of each nodule were reported by the two radiologists. A third radiologist (15 years of experience in CT) resolved by consensus differences in classification and discrepancy in measurements between the first two radiologists. In the second session, software A was used by a single radiologist, with 8 years of experience in CT, to calculate pulmonary nodule volume (cubic millimeters) of each unenhanced and contrast-enhanced acquisition. After the nodule has been identified and manually marked by the operator with a mouse click, software A performs an automatic segmentation of the nodule by combining watershed segmentation and shape-analysis techniques [13] and elaborates a 3D template model, providing a nodular volume estimate in cubic millimeters. To guarantee a completely operator-independent process, nine nodules marked by the radiologist that could not be automatically and properly (partial segmentation or oversegmentation) segmented by dedicated software package were excluded; the completeness of each nodule segmentation was examined slice by slice on axial images. Thirtyfive subjects (26 men and nine women; mean age, 60 years; range, years) with a single pulmonary nodule or a small mass lesion up to 33 mm were eventually enrolled in this study. In the third session, the anonymized data sets of the 35 pulmonary nodules evaluated with software A were transferred to a second workstation (Leonardo Workstation, Siemens Healthcare), and the same radiologist, who was blind to software A results, made the same evaluations described in the previous paragraph using software B. This software package is optimized for the evaluation of small soft-tissue density nodules of approximately spherical shape. After marking a nodule with a mouse click, a volume of interest is defined. An initial structure of interest is determined by applying a fixed density threshold and by extracting a 3D-connected structure consisting of the nodule and potential adjacent structures (e.g., vessels or parts of the chest wall). Subsequent- 150 AJR:195, July 2010

3 Contrast-Enhanced CT of Pulmonary Nodules ly, a small spherical 3D template originating from the click point is gradually expanded; its cross-correlation with the segmented nodule is computed for each step. The peak value of the cross-correlation curve is determined, and a cutoff value next to the peak value is set empirically. In this manner, an optimal spherical 3D template is generated that represents the nodule best. Finally, nodule segmentation is performed by fusing the optimal 3D template and the structure of interest, followed by spatial reasoning to remove adjacent structures [4]. Nodule attenuation Pulmonary nodules attenuation (in Hounsfield units) was reported for each unenhanced and contrast-enhanced acquisition using both software packages. provides nodule attenuation values calculated from the 3D template, so the Hounsfield unit value is an estimate of the whole nodule. Because our release of software A does not provide an automatic 3D attenuation of the nodule, 2D attenuation values (in Hounsfield units) were obtained placing a region of interest on the CT slice of maximal nodule diameter, covering 60% of the nodule area, as measured at mediastinal window settings (window width, 400 HU; window level, 40 HU) on transverse images. We retrospectively reviewed the clinical histories of the 35 subjects to determine the nodule diagnosis. Nine nodules were histologically proven lung cancer (six adenocarcinomas and three squamous cell carcinomas). The 26 remaining nodules were considered benign according to dimensional stability or regression at further followup CT examinations (mean follow-up, 37 months; range, months). Volume, mm 3 1,450 1,400 1,350 1,300 1,250 1,200 1,150 1, Time, seconds TABLE 1: Volume and Density of Lung Nodules (n = 35) Measured With Unenhanced and Contrast-Enhanced CT and Analyzed With Different Software Packages CT Scan Delay (s) Nodule Volume (mm 3 ), Mean (SD) Statistical Analysis Because the measured volumes and densities were not normally distributed, we used the nonparametric Wilcoxon s signed rank test to compare the measures of pulmonary nodule volume and density before and after contrast medium administration, at each contrast-enhanced scan delay. The same test was used to further evaluate whether there were significant variations in volume measurements among different contrast-enhanced delays. We used the Wilcoxon s two-sample test to evaluate whether increased volume and density after administration of contrast medium differed by nodule diagnosis (benign or malignant nodule). Contrast-enhanced volume ratio was calculated for each CT scan delay as contrast-enhanced nodule volume divided by unenhanced nodule volume. We evaluated the correlation between contrast-enhanced volume ratio with baseline characteristics using the Kruskal-Wallis test for categorical variables (sex, site, and shape) and the Spearman s rank correlation coefficient for continuous variables (age and unenhanced density). To evaluate whether variation between unenhanced and contrast-enhanced volume measures correlated with variation between unenhanced and contrast-enhanced density measures, we calculated the contrast-enhanced density ratio, as described for volume, and correlated it with contrast-enhanced volume ratio by Spearman s rank correlation coefficient. A p value of < 0.05 was considered statistically significant. All the statistical analysis were performed using SAS software, version 8.2 (SAS Institute). Results The 35 nodules were distributed as follows: 31% (n = 11) right upper lobe, 6% (n = Nodule Density (HU), Mean (SD) 0 1,295 (1,764) 1,226 (1,767) (19.89) (18.90) 30 1,369 (1,898) 1,268 (1,828) (19.05) (19.32) 60 1,395 (1,947) 1,278 (1,855) (34.10) (26.62) 120 1,406 (1,926) 1,299 (1,780) (28.31) (24.84) 180 1,370 (1,903) 1,290 (1,803) (24.58) (21.87) 300 1,394 (1,967) 1,299 (1,817) (28.16) (20.66) Note is ALA Single (GE Healthcare), and software B is LungCARE (Siemens Healthcare) A Volume, mm ) middle lobe, 23% (n = 8) right lower lobe, 20% (n = 7) left upper lobe, and 20% (n = 7) left lower lobe. The mean diameter of the 35 nodules, measured at unenhanced thin-section CT, was 13.8 mm (range, 8 33 mm; SD, 5.37 mm); the mean (SD) diameter of benign nodules was 12.7 mm (3.98 mm) versus 16.5 mm (7.42 mm) for malignant nodules. Fiftytwo percent were round, 34% were irregular, and 14% were polygonal. Mean volume and mean density before and after administration of contrast medium are shown in Table 1 and Figure 2. The median increase in nodule volume and density after contrast medium for each CT scan delay is shown in Table 2. The measured volumes and densities at contrast-enhanced imaging were significantly larger than those at unenhanced imaging for all the timing delays for both software packages, except at 30 seconds for software A (Table 2). We did not observe any significant difference among measurements of volume calculated at different contrast-enhanced delays for both software packages (p > 0.05). Median volume ratios between unenhanced and contrast-enhanced imaging ranged from 1.04 to 1.07 for software A and from 1.04 to 1.06 for software B. Median Time, seconds B Fig. 2 Mean pulmonary nodule volume (cubic millimeters) and density (Hounsfield units [HU]) before and after contrast material administration. A, and B, is ALA Single (GE Healthcare), and software B is LungCARE (Siemens Healthcare). AJR:195, July

4 Rampinelli et al. TABLE 2: Increase in Lung Nodule (n = 35) Volume and Density After IV Administration of Contrast Medium, Measured With Different Software Packages Nodule Measurement, CT Scan Delay Volume (mm 3 ) volume ratios within different contrast-enhanced delays ranged from 0.99 to 1.03 for software A and from 0.99 to 1.04 for software B (Table 3). According to nodule diagnosis, the median increase in volume after administration of contrast medium was larger in malignant nodules than benign nodules at 120 and 180 seconds (p = 0.04) for software A and at all time delays but 30 seconds for software B (Table 4). We did not find any significant association between contrast-enhanced volume ratio and sex, site, shape, age, unenhanced diameter, unenhanced density, or contrastenhanced density ratio (p > 0.05). Discussion This study shows that automated volume calculation of lung nodules with contrastenhanced imaging yields results larger than those for unenhanced imaging, with a median increase in contrast-enhanced volume of 4 7% for software A and 4 6% for software B, according to different scan delays. Our results were similar to those from a previous study [12], in which volume ranged by a mean of %, depending on whether a high- or low-spatial-frequency algorithm was used; however, in that study, various contrast medium concentrations, doses, injection rates, and scan delays (range, seconds) were used, which partially influenced the results. Although we used the same CT protocol, contrast material administration, and two different commercially available software packages, the reason for the increased contrast-enhanced volume is still not clear. Because nodules with visible vessel attachment were excluded in this study, surrounding microvessel enhancement could not significantly increase nodule volume. Supposing that the enhancement of the peripheral part of the nodule could enlarge the shape of the nodule, we presume that contrast-enhanced volume is affected by overestimated automated segmentation as a result of increased contrast-enhanced attenuation of the nodule s edge. This could explain why contrast material injection increased nodule volume. However, further investigations would be necessary to clarify TABLE 3: Pulmonary Nodule Volume Ratios at Different CT Scan Delays, According to Different Software Packages Time Comparison (s) Difference Between Contrast-Enhanced Difference Between Contrast-Enhanced and Unenhanced Scan, Median (Range) p a and Unenhanced Scan, Median (Range) 30 s 37 ( 277 to 671) ( 114 to 380) s 35 ( 487 to 1,082) ( 393 to 545) s 31 ( 1,057 to 800) ( 69 to 526) < s 36 ( 1,109 to 689) ( 214 to 579) s 14 ( 481 to 1,123) ( 358 to 539) Density (HU) 30 seconds 3.15 ( to 44.08) ( to 55.00) seconds 8.66 ( to 69.88) ( to ) < seconds ( to 70.32) < ( 5.0 to ) < seconds ( to 69.98) < ( 3.0 to ) < seconds ( to 65.45) < ( 2.00 to ) < Note is ALA Single (GE Healthcare), and software B is LungCARE (Siemens Healthcare). a Wilcoxon s signed rank test. Volume Ratio, Median (Range) 30 vs ( ) 1.04 ( ) 60 vs ( ) 1.04 ( ) 120 vs ( ) 1.06 ( ) 180 vs ( ) 1.06 ( ) 300 vs ( ) 1.04 ( ) 60 vs ( ) 1.00 ( ) 120 vs ( ) 1.02 ( ) 180 vs ( ) 1.04 ( ) 300 vs ( ) 1.03 ( ) 120 vs ( ) 1.03 ( ) 180 vs ( ) 1.02 ( ) 300 vs ( ) 1.02 ( ) 180 vs ( ) 0.99 ( ) 300 vs ( ) 1.00 ( ) 300 vs ( ) 1.00 ( ) Note is ALA Single (GE Healthcare), and software B is LungCARE (Siemens Healthcare). p a 152 AJR:195, July 2010

5 Contrast-Enhanced CT of Pulmonary Nodules TABLE 4: Increase in Nodule Volume and Density After Administration of Contrast Material, by Nodule Nature and According to Different Software Packages Nodule Measurement, CT Scan Delay Benign Nodule this important issue, particularly regarding the correlation between degree of lung nodule attenuation values and volume variation. To our knowledge, no previous studies have investigated the effects of different contrast-enhanced CT scan delays on nodule volumetric measurements. Our results show that automated volume variation was not significantly different within contrast-enhanced CT scan delays, ranging from 1% to 3% for software A and from 1% to 4% for software B; thus, in clinical practice, volume measurements obtained by enhanced CT performed with different scan delays are comparable. In addition, we have evaluated the association between increased contrast-enhanced volume and nodule diagnosis, obtaining a median increase in volume larger in malignant than in benign nodules at 120 and 180 seconds only for software A and at all time delays except 30 seconds for software B. This finding could be explained by the higher degree of contrast enhancement of malignant nodules, but in view of the small number (n = 9) of malignant nodules, we cannot draw any significant conclusions. The standard algorithm (relatively lowspatial-frequency algorithm) was used for image reconstruction in this study. Even though a high-spatial-frequency algorithm has been recommended for volumetric evaluation, the standard algorithm used can be Malignant Benign Nodule p a Nodule Malignant Nodule Volume (mm 3 ) 30 s s s s s Density (HU) 30 s s s s s Note Except for p values, data are median differences between contrast-enhanced and unenhanced scans. is ALA Single (GE Healthcare), and software B is LungCARE (Siemens Healthcare). a Wilcoxon s two-sample test. considered accurate because no substantial differences in the accuracy of volume estimations across seven different reconstruction kernels were reported in a previous in vitro study [14]. This study has some limitations. First, a small number of nodules were examined. Although our results achieved statistical significance, a larger number of nodules would improve information and clarify some aspects of this topic. A second limitation concerns the different methods used to calculate the lung nodule attenuation, which was evaluated in 2D with software A and in 3D with software B; however, with both methods, we did not find any significant correlation between volume variation and degree of contrast-enhanced nodule attenuation. A third limitation concerns the characteristics of the nodules chosen as targets of the study (i.e., solid nodules with no visible pleural or vascular contact). We decided to use this target to allow evaluation of volume variation in an optimal condition. In fact, evaluation of repeatability could have been further influenced by juxtapleural or juxtavascular or nonsolid nodules [15]. Finally, the results reported in this study are strictly tied to the performance of the two software packages used, and the inherent variability of the software could affect the volumetric analysis, particularly for small nodules [16]; however, p a in this study, we did not find any significant association between contrast-enhanced volume variation and nodule diameter. In conclusion, regardless of the two different software packages used, automated volume calculation of pulmonary nodules is significantly larger after contrast material administration, and different contrastenhanced CT scan delays provided similar volumetric measurements. The meaning of contrast-enhanced variation is even more important if it is added to other variables that could affect nodule volume calculation in follow-up CT examinations [5 11]. Thus, in clinical practice, we recommend comparing automated volume of lung nodules obtained from CT examinations only if they are all performed with or without contrast material, whereas nodule volume obtained from enhanced CT examinations performed with different scan delays are comparable. References 1. Revel MP, Bissery A, Bienvenu M, Aycard L, Lefort C, Frija G. Are two-dimensional CT measurements of small noncalcified pulmonary nodules reliable? Radiology 2004; 231: Marten K, Auer F, Schmidt S, Kohl G, Rummeny EJ, Engelke C. Inadequacy of manual measurements compared to automated CT volumetry in assessment of treatment response of pulmonary metastases using RECIST criteria. Eur Radiol 2006; 16: Goodman LR, Gulsun M, Washington L, Nagy PG, Piacsek KL. Inherent variability of CT lung nodule measurements in vivo using semiautomated volumetric measurements. AJR 2006; 186: Wormanns D, Kohl G, Klotz E, et al. Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility. Eur Radiol 2004; 14: Petkovska I, Brown MS, Goldin JG, et al. The effect of lung volume on nodule size on CT. Acad Radiol 2007; 14: Gietema HA, Schaefer-Prokop CM, Mali WP, Groenewegen G, Prokop M. Pulmonary nodules: interscan variability of semiautomated volume measurements with multisection CT influence of inspiration level, nodule size, and segmentation performance. Radiology 2007; 245: Boll DT, Gilkeson RC, Fleiter TR, Blackham KA, Duerk JL, Lewin JS. Volumetric assessment of pulmonary nodules with ECG-gated MDCT. AJR 2004; 183: Goo JM, Kim KG, Gierada DS, Castro M, Bae KT. Volumetric measurements of lung nodules with multi-detector row CT: effect of changes in AJR:195, July

6 Rampinelli et al. lung volume. Korean J Radiol 2006; 7: FOR YOUR INFORMATION 9. Wang Y, van Klaveren RJ, van der Zaag-Loonen HJ, et al. Effect of nodule characteristics on variability of semiautomated volume measurements in pulmonary nodules detected in a lung cancer screening program. Radiology 2008; 248: Honda O, Sumikawa H, Johkoh T, et al. Computer-assisted lung nodule volumetry from multi-detector row CT: influence of image reconstruction parameters. Eur J Radiol 2007; 62: Goo JM, Tongdee T, Tongdee R, Yeo K, Hildebolt CF, Bae KT. Volumetric measurement of synthetic lung nodules with multi-detector row CT: effect of various image reconstruction parameters and segmentation thresholds on measurement accuracy. Radiology 2005; 235: Honda O, Johkoh T, Sumikawa H, et al. Pulmonary nodules: 3D volumetric measurement with multidetector CT effect of intravenous contrast medium. Radiology 2007; 245: Revel MP, Lefort C, Bissery A, et al. Pulmonary nodules: preliminary experience with three-dimensional evaluation. Radiology 2004; 231: Ravenel JG, Leue WM, Nietert PJ, Miller JV, Taylor KK, Silvestri GA. Pulmonary nodule volume: effects of reconstruction parameters on automated measurements a phantom study. Radiology 2008; 247: Ko JP, Marcus R, Bomsztyk E, et al. Effect of blood vessels on measurement of nodule volume in a chest phantom. Radiology 2006; 239: Rampinelli C, De Fiori E, Raimondi S, Veronesi G, Bellomi M. In vivo repeatability of automated volume calculations of small pulmonary nodules with CT. AJR 2009; 192: Unique customized medical search engine service from ARRS! ARRS GoldMiner is a keyword- and concept-driven search engine that provides instant access to radiologic images published in peer-reviewed journals. For more information, visit AJR:195, July 2010

Chapter 6. Hester Gietema Cornelia Schaefer-Prokop Willem Mali Gerard Groenewegen Mathias Prokop. Accepted for publication in Radiology

Chapter 6. Hester Gietema Cornelia Schaefer-Prokop Willem Mali Gerard Groenewegen Mathias Prokop. Accepted for publication in Radiology Chapter 6 Interscan variability of semiautomated volume measurements in intraparenchymal pulmonary nodules using multidetector-row computed tomography: Influence of inspirational level, nodule size and

More information

Pulmonary Nodule Volumetric Measurement Variability as a Function of CT Slice Thickness and Nodule Morphology

Pulmonary Nodule Volumetric Measurement Variability as a Function of CT Slice Thickness and Nodule Morphology CT of Pulmonary Nodules Chest Imaging Original Research Myria Petrou 1 Leslie E. Quint 1 in Nan 2 Laurence H. aker 3 Petrou M, Quint LE, Nan, aker LH Keywords: chest, lung disease, MDCT, oncologic imaging,

More information

Methods and validation of nodule measurement in a lung cancer screening Ying, Wang

Methods and validation of nodule measurement in a lung cancer screening Ying, Wang University of Groningen Methods and validation of nodule measurement in a lung cancer screening Ying, Wang IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish

More information

Chapter 5. Pulmonary nodules detected at lung cancer screening: Interobserver variability of semiautomated volume measurements

Chapter 5. Pulmonary nodules detected at lung cancer screening: Interobserver variability of semiautomated volume measurements Chapter 5 Pulmonary nodules detected at lung cancer screening: Interobserver variability of semiautomated volume measurements Hester Gietema Ying Wang Dongming Xu Rob van Klaveren Harry de Koning Ernst

More information

Small Pulmonary Nodules: Our Preliminary Experience in Volumetric Analysis of Doubling Times

Small Pulmonary Nodules: Our Preliminary Experience in Volumetric Analysis of Doubling Times Small Pulmonary Nodules: Our Preliminary Experience in Volumetric Analysis of Doubling Times Andrea Borghesi, MD Davide Farina, MD Roberto Maroldi, MD Department of Radiology University of Brescia Brescia,

More information

Computer-Aided Volumetry of Pulmonary Nodules Exhibiting Ground-Glass Opacity at MDCT

Computer-Aided Volumetry of Pulmonary Nodules Exhibiting Ground-Glass Opacity at MDCT Cardiopulmonary Imaging Original Research Oda et al. MDCT and Volumetry of Pulmonary Nodules Cardiopulmonary Imaging Original Research Computer-Aided Volumetry of Pulmonary Nodules Exhibiting Ground-Glass

More information

Copyright 2007 Society of Photo Optical Instrumentation Engineers. This paper was published in Proceedings of SPIE, volume 6514, Medical Imaging

Copyright 2007 Society of Photo Optical Instrumentation Engineers. This paper was published in Proceedings of SPIE, volume 6514, Medical Imaging Copyright 2007 Society of Photo Optical Instrumentation Engineers. This paper was published in Proceedings of SPIE, volume 6514, Medical Imaging 2007: Computer Aided Diagnosis and is made available as

More information

Ryutaro Kakinuma 1,2,3, Yukio Muramatsu 1,4, Junta Yamamichi 1,5, Shiho Gomi 1,6, Estanislao Oubel 7, Noriyuki Moriyama 1,8.

Ryutaro Kakinuma 1,2,3, Yukio Muramatsu 1,4, Junta Yamamichi 1,5, Shiho Gomi 1,6, Estanislao Oubel 7, Noriyuki Moriyama 1,8. Original Article Evaluation of the 95% limits of agreement of the volumes of 5-year clinically stable solid nodules for the development of a follow-up system for indeterminate solid nodules in CT lung

More information

REVIEW. A practical approach to radiological evaluation of CT lung cancer screening examinations

REVIEW. A practical approach to radiological evaluation of CT lung cancer screening examinations Cancer Imaging (2013) 13(3), 391 399 DOI: 10.1102/1470-7330.2013.9043 REVIEW A practical approach to radiological evaluation of CT lung cancer screening examinations Xueqian Xie a,b, Marjolein A. Heuvelmans

More information

Lung nodule volumetry: segmentation algorithms within the same software package cannot be used interchangeably

Lung nodule volumetry: segmentation algorithms within the same software package cannot be used interchangeably Eur Radiol (2010) 20: 1878 1885 DOI 10.1007/s00330-010-1749-z COMPUTED TOMOGRAPHY H. Ashraf B. de Hoop S. B. Shaker A. Dirksen K. S. Bach H. Hansen M. Prokop J. H. Pedersen Lung nodule volumetry: segmentation

More information

The utility of automated volumetric growth analysis in a dedicated pulmonary nodule clinic

The utility of automated volumetric growth analysis in a dedicated pulmonary nodule clinic General Thoracic Surgery Korst et al The utility of automated volumetric growth analysis in a dedicated pulmonary nodule clinic Robert J. Korst, MD, a,b Benjamin E. Lee, MD, a,b Glenn A. Krinsky, MD, c

More information

Low-dose CT Lung Cancer Screening Guidelines for Pulmonary Nodules Management Version 2

Low-dose CT Lung Cancer Screening Guidelines for Pulmonary Nodules Management Version 2 Low-dose CT Lung Cancer Screening Guidelines for Pulmonary Nodules Management Version 2 The Committee for Management of CT-screening-detected Pulmonary Nodules 2009-2011 The Japanese Society of CT Screening

More information

Malignant solitary pulmonary nodules: assessment of mass growth rate and doubling time at follow-up CT

Malignant solitary pulmonary nodules: assessment of mass growth rate and doubling time at follow-up CT Original Article Malignant solitary pulmonary nodules: assessment of mass growth rate and doubling time at follow-up CT Jingxu Li*, Tingting Xia*, Xinguan Yang, Xiao Dong, Jiamin Liang, Nanshan Zhong,

More information

With the introduction of multidetector computed tomography (CT) and the ongoing advances in multidetector CT technology, the detection of small pulmon

With the introduction of multidetector computed tomography (CT) and the ongoing advances in multidetector CT technology, the detection of small pulmon Note: This copy is for your personal non-commercial use only. To order presentation-ready copies for distribution to your colleagues or clients, contact us at www.rsna.org/rsnarights. Effect of Nodule

More information

Use of Volumetry for Lung Nodule Management: Theory and Practice 1

Use of Volumetry for Lung Nodule Management: Theory and Practice 1 This copy is for personal use only. To order printed copies, contact reprints@rsna.org Reviews and Commentary n State of the Art Anand Devaraj, BSc, MRCP, FRCR, MD Bram van Ginneken, PhD Arjun Nair, MRCP,

More information

Guidelines for the Management of Pulmonary Nodules Detected by Low-dose CT Lung Cancer Screening

Guidelines for the Management of Pulmonary Nodules Detected by Low-dose CT Lung Cancer Screening Guidelines for the Management of Pulmonary Nodules Detected by Low-dose CT Lung Cancer Screening 1. Introduction In January 2005, the Committee for Preparation of Clinical Practice Guidelines for the Management

More information

Cardiopulmonary Imaging Original Research. T screening has increased the rate of detection of small nodules,

Cardiopulmonary Imaging Original Research. T screening has increased the rate of detection of small nodules, Cardiopulmonary Imaging Original Research Christe et al. CT of Lung Nodules Cardiopulmonary Imaging Original Research CT Screening and Follow-Up of Lung Nodules: Effects of Tube Current Time Setting and

More information

Pulmonary Nodule Size Evaluation with Chest Tomosynthesis 1

Pulmonary Nodule Size Evaluation with Chest Tomosynthesis 1 Note: This copy is for your personal non-commercial use only. To order presentation-ready copies for distribution to your colleagues or clients, contact us at www.rsna.org/rsnarights. Åse A. Johnsson,

More information

Small Irregular Pulmonary Nodules in Low-Dose CT: Observer Detection Sensitivity and Volumetry Accuracy

Small Irregular Pulmonary Nodules in Low-Dose CT: Observer Detection Sensitivity and Volumetry Accuracy Cardiopulmonary Imaging Original Research Xie et al. CT of Phantom Model of Small Irregular Pulmonary Nodules Cardiopulmonary Imaging Original Research FOCUS ON: Xueqian Xie 1,2 Martin J. Willemink 3 Pim

More information

Performance of computer-aided detection of pulmonary nodules in low-dose CT: comparison with double reading by nodule volume

Performance of computer-aided detection of pulmonary nodules in low-dose CT: comparison with double reading by nodule volume Eur Radiol (2012) 22:2076 2084 DOI 10.1007/s00330-012-2437-y CHEST Performance of computer-aided detection of pulmonary nodules in low-dose CT: comparison with double reading by nodule volume Yingru Zhao

More information

Computer-Aided Detection in Screening CT for

Computer-Aided Detection in Screening CT for Yuan et al. Screening CT for Pulmonary Chest Imaging Original Research C M E D E N T U R I C L I M G I N G JR 2006; 186:1280 1287 0361 803X/06/1865 1280 merican Roentgen Ray Society Y O Ren Yuan 1 Patrick

More information

Acknowledgments. A Specific Diagnostic Task: Lung Nodule Detection. A Specific Diagnostic Task: Chest CT Protocols. Chest CT Protocols

Acknowledgments. A Specific Diagnostic Task: Lung Nodule Detection. A Specific Diagnostic Task: Chest CT Protocols. Chest CT Protocols Personalization of Pediatric Imaging in Terms of Needed Indication-Based Quality Per Dose Acknowledgments Duke University Medical Center Ehsan Samei, PhD Donald Frush, MD Xiang Li PhD DABR Cleveland Clinic

More information

Volume versus diameter assessment of small pulmonary nodules in CT lung cancer screening

Volume versus diameter assessment of small pulmonary nodules in CT lung cancer screening Review Article Volume versus diameter assessment of small pulmonary nodules in CT lung cancer screening Daiwei Han, Marjolein A. Heuvelmans, Matthijs Oudkerk University of Groningen, University Medical

More information

Chapter 11. Summary and general discussion

Chapter 11. Summary and general discussion Chapter 11 Summary and general discussion Low Dose Computed Tomography of the Chest: Applications and Limitations INTRODUCTION The introduction of spiral, multidetector-row computed tomography (CT) has

More information

New Horizons in the Imaging of the Lung

New Horizons in the Imaging of the Lung New Horizons in the Imaging of the Lung Postprocessing. How to do it and when do we need it? Peter M.A. van Ooijen, MSc, PhD Principal Investigator, Radiology, UMCG Discipline Leader Medical Imaging Informatics

More information

Copyright 2009 Society of Photo Optical Instrumentation Engineers. This paper was published in Proceedings of SPIE, vol. 7260, Medical Imaging 2009:

Copyright 2009 Society of Photo Optical Instrumentation Engineers. This paper was published in Proceedings of SPIE, vol. 7260, Medical Imaging 2009: Copyright 2009 Society of Photo Optical Instrumentation Engineers. This paper was published in Proceedings of SPIE, vol. 7260, Medical Imaging 2009: Computer Aided Diagnosis and is made available as an

More information

Measurement error of spiral CT Volumetry:

Measurement error of spiral CT Volumetry: Measurement error of spiral CT Volumetry: Influence of Low Dose CT Technique 1 Tae Gyu Lee, M.D. 2, Myung Jin Chung, M.D., Sung Bum Cho, M.D. 2, Jae Min Cho, M.D., Seog Joon Kim, M.D. 2, Sang Hyun Baik,

More information

Copyright 2007 IEEE. Reprinted from 4th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, April 2007.

Copyright 2007 IEEE. Reprinted from 4th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, April 2007. Copyright 27 IEEE. Reprinted from 4th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, April 27. This material is posted here with permission of the IEEE. Such permission of the

More information

By choosing to view this document, you agree to all provisions of the copyright laws protecting it.

By choosing to view this document, you agree to all provisions of the copyright laws protecting it. Copyright 2009 IEEE. Reprinted from 31 st Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2009. EMBC 2009. Sept. 2009. This material is posted here with permission

More information

PULMONARY EMBOLISM ANGIOCT (CTA) ASSESSMENT OF VASCULAR OCCLUSION EXTENT AND LOCALIZATION OF EMBOLI 1. BACKGROUND

PULMONARY EMBOLISM ANGIOCT (CTA) ASSESSMENT OF VASCULAR OCCLUSION EXTENT AND LOCALIZATION OF EMBOLI 1. BACKGROUND JOURNAL OF MEDICAL INFORMATICS & TECHNOLOGIES Vol. 11/2007, ISSN 1642-6037 Damian PTAK * pulmonary embolism, AngioCT, postprocessing techniques, Mastora score PULMONARY EMBOLISM ANGIOCT (CTA) ASSESSMENT

More information

Volume and Mass Doubling Times of Persistent Pulmonary Subsolid Nodules Detected in Patients without Known Malignancy 1

Volume and Mass Doubling Times of Persistent Pulmonary Subsolid Nodules Detected in Patients without Known Malignancy 1 Note: This copy is for your personal non-commercial use only. To order presentation-ready copies for distribution to your colleagues or clients, contact us at www.rsna.org/rsnarights. Original Research

More information

Customizing Contrast Injection for Body MDCT: Algorithmic Approach

Customizing Contrast Injection for Body MDCT: Algorithmic Approach Customizing Contrast Injection for Body MDCT: Algorithmic Approach Lincoln L. Berland, M.D., F.A.C.R. University of Alabama at Birmingham Before Contrast Prep and Hydration Hydration single most important

More information

Clinical Significance of Lung Nodules Reported on Abdominal CT

Clinical Significance of Lung Nodules Reported on Abdominal CT Cardiopulmonary Imaging Original Research Alpert et al. Significance of Lung Nodules on Abdominal CT Cardiopulmonary Imaging Original Research Jeffrey B. Alpert 1 John P. Fantauzzi Kira Melamud Heather

More information

Improvement of Image Quality with ß-Blocker Premedication on ECG-Gated 16-MDCT Coronary Angiography

Improvement of Image Quality with ß-Blocker Premedication on ECG-Gated 16-MDCT Coronary Angiography 16-MDCT Coronary Angiography Shim et al. 16-MDCT Coronary Angiography Sung Shine Shim 1 Yookyung Kim Soo Mee Lim Received December 1, 2003; accepted after revision June 1, 2004. 1 All authors: Department

More information

Prevent Cancer Foundation Quantitative Imaging Workshop XIII

Prevent Cancer Foundation Quantitative Imaging Workshop XIII Status of the Quantitative Imaging Profile Lung Nodule Volume Assessment and Monitoring in Low Dose CT Screening Prevent Cancer Foundation Quantitative Imaging Workshop XIII June 13-14, 2016 David S. Gierada,

More information

Outcomes in the NLST. Health system infrastructure needs to implement screening

Outcomes in the NLST. Health system infrastructure needs to implement screening Outcomes in the NLST Health system infrastructure needs to implement screening Denise R. Aberle, MD Professor of Radiology and Bioengineering David Geffen School of Medicine at UCLA 1 Disclosures I have

More information

Improved image quality of low-dose thoracic CT examinations with a new postprocessing software*

Improved image quality of low-dose thoracic CT examinations with a new postprocessing software* JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 11, NUMBER 3, Summer 2010 Improved image quality of low-dose thoracic CT examinations with a new postprocessing software* Anne Catrine Traegde Martinsen,

More information

Pseudoenhancement of Renal Cysts: Influence of Lesion Size, Lesion Location, Slice Thickness, and Number of MDCT Detectors

Pseudoenhancement of Renal Cysts: Influence of Lesion Size, Lesion Location, Slice Thickness, and Number of MDCT Detectors Genitourinary Imaging Original Research Tappouni et al. MDCT of Renal Cysts Genitourinary Imaging Original Research Rafel Tappouni 1 Jennifer Kissane 2 Nabeel Sarwani 1 Erik B. Lehman 1 Tappouni R, Kissane

More information

University of Groningen. Optimization of nodule management in CT lung cancer screening Heuvelmans, Marjolein

University of Groningen. Optimization of nodule management in CT lung cancer screening Heuvelmans, Marjolein University of Groningen Optimization of nodule management in CT lung cancer screening Heuvelmans, Marjolein IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish

More information

C2 COMPLETION INSTRUCTIONS

C2 COMPLETION INSTRUCTIONS The C2 Form is completed for each screening exam at T0, T1, and T2. The C2 Form is to be completed by each of the following ACRIN-NLST study staff: the research associate (study coordinator), CT technologist,

More information

Lung Cancer Risk Associated With New Solid Nodules in the National Lung Screening Trial

Lung Cancer Risk Associated With New Solid Nodules in the National Lung Screening Trial Cardiopulmonary Imaging Original Research Pinsky et al. Lung Cancer Risk Associated With New Nodules Cardiopulmonary Imaging Original Research Paul F. Pinsky 1 David S. Gierada 2 P. Hrudaya Nath 3 Reginald

More information

University of Groningen. Optimization of nodule management in CT lung cancer screening Heuvelmans, Marjolein

University of Groningen. Optimization of nodule management in CT lung cancer screening Heuvelmans, Marjolein University of Groningen Optimization of nodule management in CT lung cancer screening Heuvelmans, Marjolein IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish

More information

Radiation Dose Reduction: Should You Use a Bismuth Breast Shield?

Radiation Dose Reduction: Should You Use a Bismuth Breast Shield? Radiation Dose Reduction: Should You Use a Bismuth Breast Shield? Lincoln L. Berland, M.D., F.A.C.R. Michael V. Yester, Ph.D. University of Alabama at Birmingham Breast Radiation on CT Use of chest CT

More information

Comparison of CT findings between MDR-TB and XDR-TB

Comparison of CT findings between MDR-TB and XDR-TB Comparison of CT findings between MDR-TB and XDR-TB Poster No.: C-0757 Congress: ECR 2017 Type: Authors: Keywords: DOI: Scientific Exhibit K. Yoon, H. Soohee; Changwon-si/KR Thorax, Lung, Respiratory system,

More information

Scientific Exhibit. Authors: D. Takenaka, Y. Ohno, Y. Onishi, K. Matsumoto, T.

Scientific Exhibit. Authors: D. Takenaka, Y. Ohno, Y. Onishi, K. Matsumoto, T. The feasibility of biphasic contrast-media-injection-protocol for chest imaging on 320-slice volume MDCT: Direct comparison of biphasic and bolus contrast-media injection protocols on 320-slice volume

More information

Feasibility of contrast agent volume reduction on 640-slice CT coronary angiography in patients with low heart rate

Feasibility of contrast agent volume reduction on 640-slice CT coronary angiography in patients with low heart rate Feasibility of contrast agent volume reduction on 640-slice CT coronary angiography in patients with low heart rate Poster No.: B-0742 Congress: ECR 2013 Type: Authors: Keywords: DOI: Scientific Paper

More information

Radiologic assessment of response of tumors to treatment. Copyright 2008 TIMC, Matthew A. Barish M.D. All rights reserved. 1

Radiologic assessment of response of tumors to treatment. Copyright 2008 TIMC, Matthew A. Barish M.D. All rights reserved. 1 Radiologic assessment of response of tumors to treatment Copyright 2008 TIMC, Matthew A. Barish M.D. All rights reserved. 1 Objective response assessment is important to describe the treatment effect of

More information

Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement

Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement 3 rd Annual Imaging & Physiology Summit November 20-21, 21, 2009 Seoul, Korea Wm. Guy Weigold, MD, FACC Cardiovascular

More information

Small solid noncalcified pulmonary nodules detected by screening chest computed tomography

Small solid noncalcified pulmonary nodules detected by screening chest computed tomography Respiratory Medicine (2007) 101, 1880 1884 Small solid noncalcified pulmonary nodules detected by screening chest computed tomography Sang-Man Jin a,b, Seung-Ho Choi c, Chul-Gyu Yoo a,b, Young-Whan Kim

More information

Diffuse high-attenuation within mediastinal lymph nodes on non-enhanced CT scan: Usefulness in the prediction of benignancy

Diffuse high-attenuation within mediastinal lymph nodes on non-enhanced CT scan: Usefulness in the prediction of benignancy Diffuse high-attenuation within mediastinal lymph nodes on non-enhanced CT scan: Usefulness in the prediction of benignancy Poster No.: C-1785 Congress: ECR 2012 Type: Authors: Keywords: DOI: Scientific

More information

IEEE TRANSACTIONS ON MEDICAL IMAGING, VOL. 25, NO. 4, APRIL

IEEE TRANSACTIONS ON MEDICAL IMAGING, VOL. 25, NO. 4, APRIL IEEE TRANSACTIONS ON MEDICAL IMAGING, VOL. 25, NO. 4, APRIL 2006 435 On Measuring the Change in Size of Pulmonary Nodules Anthony P. Reeves*, Senior Member, IEEE, Antoni B. Chan, David F. Yankelevitz,

More information

8/3/2016. Consultant for / research support from: Astellas Bayer Bracco GE Healthcare Guerbet Medrad Siemens Healthcare. Single Energy.

8/3/2016. Consultant for / research support from: Astellas Bayer Bracco GE Healthcare Guerbet Medrad Siemens Healthcare. Single Energy. U. Joseph Schoepf, MD Prof. (h.c.), FAHA, FSCBT-MR, FNASCI, FSCCT Professor of Radiology, Medicine, and Pediatrics Director, Division of Cardiovascular Imaging Consultant for / research support from: Astellas

More information

Identification of Missed Pulmonary Nodules on Low Dose CT Lung Cancer Screening Studies Using an Automatic Detection System

Identification of Missed Pulmonary Nodules on Low Dose CT Lung Cancer Screening Studies Using an Automatic Detection System Identification of Missed Pulmonary Nodules on Low Dose CT Lung Cancer Screening Studies Using an Automatic Detection System Carol L. Novak *a, Li Fan a, Jianzhong Qian a, Guo-Qing Wei a, David P. Naidich

More information

Chest CT with Ultra-High Resolution Collimator for Submillimeter Fat Plane Detection: A Phantom Study

Chest CT with Ultra-High Resolution Collimator for Submillimeter Fat Plane Detection: A Phantom Study Chest CT with Ultra-High Resolution Collimator for Submillimeter Fat Plane Detection: A Phantom Study Poster No.: C-1207 Congress: ECR 2013 Type: Scientific Exhibit Authors: Y. Shimomiya, M. Kondo, M.

More information

Biases affecting tumor uptake measurements in FDG-PET

Biases affecting tumor uptake measurements in FDG-PET Biases affecting tumor uptake measurements in FDG-PET M. Soret, C. Riddell, S. Hapdey, and I. Buvat Abstract-- The influence of tumor diameter, tumor-tobackground activity ratio, attenuation, spatial resolution,

More information

Comparison of RECIST version 1.0 and 1.1 in assessment of tumor response by computed tomography in advanced gastric cancer

Comparison of RECIST version 1.0 and 1.1 in assessment of tumor response by computed tomography in advanced gastric cancer Original Article Comparison of RECIST version 1.0 and 1.1 in assessment of tumor response by computed tomography in advanced gastric cancer Gil-Su Jang 1 *, Min-Jeong Kim 2 *, Hong-Il Ha 2, Jung Han Kim

More information

Computer based delineation and follow-up multisite abdominal tumors in longitudinal CT studies

Computer based delineation and follow-up multisite abdominal tumors in longitudinal CT studies Research plan submitted for approval as a PhD thesis Submitted by: Refael Vivanti Supervisor: Professor Leo Joskowicz School of Engineering and Computer Science, The Hebrew University of Jerusalem Computer

More information

Lung nodules: size still matters

Lung nodules: size still matters SERIES RADIOLOGY Lung nodules: size still matters Anna Rita Larici, Alessandra Farchione, Paola Franchi, Mario Ciliberto, Giuseppe Cicchetti, Lucio Calandriello, Annemilia del Ciello and Lorenzo Bonomo

More information

PULMONARY NODULES AND MASSES : DIAGNOSTIC APPROACH AND NEW MANAGEMENT GUIDELINES. https://tinyurl.com/hmpn2018

PULMONARY NODULES AND MASSES : DIAGNOSTIC APPROACH AND NEW MANAGEMENT GUIDELINES. https://tinyurl.com/hmpn2018 PULMONARY NODULES AND MASSES : DIAGNOSTIC APPROACH AND NEW MANAGEMENT GUIDELINES Heber MacMahon MB, BCh Department of Radiology The University of Chicago https://tinyurl.com/hmpn2018 Disclosures Consultant

More information

SCBT-MR 2016 Lung Cancer Screening in Practice: State of the Art

SCBT-MR 2016 Lung Cancer Screening in Practice: State of the Art SCBT-MR 2016 Lung Cancer Screening in Practice: State of the Art Reginald F. Munden MD, DMD, MBA I have no conflicts of interest to report National Lung Cancer Screening Trial 20% lung cancer mortality

More information

Contrast agents, Abdomen, CT, Contrast agent-intravenous, Cancer /ecr2015/C-1760

Contrast agents, Abdomen, CT, Contrast agent-intravenous, Cancer /ecr2015/C-1760 Can Weight-Adapted IV Contrast Media Protocols Reduce Iodine Dose and Still Produce a Diagnostic Contrast Enhancement Level in Abdomino-Pelvic CT Scans? Poster No.: C-1760 Congress: ECR 2015 Type: Authors:

More information

Ultralow Dose Chest CT with MBIR

Ultralow Dose Chest CT with MBIR Ultralow Dose Chest CT with MBIR Ella A. Kazerooni, M.D. Professor & Director Cardiothoracic Radiology Associate Chair for Clinical Affairs University of Michigan Disclosures Consultant: GE Healthcare

More information

Automated Detection of Polyps from Multi-slice CT Images using 3D Morphologic Matching Algorithm: Phantom Study

Automated Detection of Polyps from Multi-slice CT Images using 3D Morphologic Matching Algorithm: Phantom Study Automated Detection of Polyps from Multi-slice CT Images using 3D Morphologic Matching Algorithm: Phantom Study Yonghum Na, Jin Sung Kim, Bruce R Whiting, K. Ty Bae Electronic Radiology Laboratory, Mallinckrodt

More information

Coronary Calcium Screening Using Low-Dose Lung Cancer Screening: Effectiveness of MDCT with Retrospective Reconstruction

Coronary Calcium Screening Using Low-Dose Lung Cancer Screening: Effectiveness of MDCT with Retrospective Reconstruction Cardiac Imaging Original Research Kim et al. Coronary Calcium Screening Using Lung Cancer Screening Cardiac Imaging Original Research Sung Mok Kim 1 Myung Jin Chung 1 Kyung Soo Lee 1 Yeon Hyun Choe 1 Chin

More information

B. CT protocols for the spine

B. CT protocols for the spine B. CT protocols for the spine Poster No.: A-003 Congress: ECR 2010 Type: Invited Speaker Topic: Neuro Authors: B. Tins; Oswestry/UK Keywords: CT, spine, diagnostic imaging protocol DOI: 10.1594/ecr2010/A-003

More information

Xiaohuan Pan 1,2 *, Xinguan Yang 1,2 *, Jingxu Li 1,2, Xiao Dong 1,2, Jianxing He 2,3, Yubao Guan 1,2. Original Article

Xiaohuan Pan 1,2 *, Xinguan Yang 1,2 *, Jingxu Li 1,2, Xiao Dong 1,2, Jianxing He 2,3, Yubao Guan 1,2. Original Article Original Article Is a 5-mm diameter an appropriate cut-off value for the diagnosis of atypical adenomatous hyperplasia and adenocarcinoma in situ on chest computed tomography and pathological examination?

More information

Analysis of Changes in Attenuation of Proven Renal Cysts on Different Scanning Phases of Triphasic MDCT

Analysis of Changes in Attenuation of Proven Renal Cysts on Different Scanning Phases of Triphasic MDCT Eugene P. Chung 1 Brian R. Herts 1,2 Grant Linnell 1 Andrew C. Novick 2 Nancy Obuchowski 1,3 Deirdre M. Coll 1,4 Mark E. Baker 1 Received June 24, 2003; accepted after revision August 28, 2003. Presented

More information

Cardiac CT - Coronary Calcium Basics Workshop II (Basic)

Cardiac CT - Coronary Calcium Basics Workshop II (Basic) Cardiac CT - Coronary Calcium Basics Workshop II (Basic) J. Jeffrey Carr, MD, MSCE Dept. of Radiology & Public Health Sciences Wake Forest University School of Medicine Winston-Salem, NC USA No significant

More information

Translating Protocols Across Patient Size: Babies to Bariatric

Translating Protocols Across Patient Size: Babies to Bariatric Translating Protocols Across Patient Size: Babies to Bariatric Cynthia H. McCollough, PhD, FACR, FAAPM Professor of Radiologic Physics Director, CT Clinical Innovation Center Department of Radiology Mayo

More information

University of Groningen

University of Groningen University of Groningen Role of baseline nodule density and changes in density and nodule features in the discrimination between benign and malignant solid indeterminate pulmonary nodules Xu, D.M.; van

More information

Recommendations for Measuring Pulmonary Nodules at CT: A Statement from the Fleischner Society 1

Recommendations for Measuring Pulmonary Nodules at CT: A Statement from the Fleischner Society 1 This copy is for personal use only. To order printed copies, contact reprints@rsna.org Alexander A. Bankier, MD, PhD Heber MacMahon, MB, BCh Jin Mo Goo, MD, PhD Geoffrey D. Rubin, MD Cornelia M. Schaefer-Prokop,

More information

Copyright 2008 Society of Photo Optical Instrumentation Engineers. This paper was published in Proceedings of SPIE, vol. 6915, Medical Imaging 2008:

Copyright 2008 Society of Photo Optical Instrumentation Engineers. This paper was published in Proceedings of SPIE, vol. 6915, Medical Imaging 2008: Copyright 2008 Society of Photo Optical Instrumentation Engineers. This paper was published in Proceedings of SPIE, vol. 6915, Medical Imaging 2008: Computer Aided Diagnosis and is made available as an

More information

Gemstone Spectral Imaging quantifies lesion characteristics for a confident diagnosis

Gemstone Spectral Imaging quantifies lesion characteristics for a confident diagnosis GE Healthcare Gemstone Spectral Imaging quantifies lesion characteristics for a confident diagnosis CT clinical case study lesion characterization Desiree Morgan, MD Vice Chair of Clinical Research Professor

More information

With recent advances in diagnostic imaging technologies,

With recent advances in diagnostic imaging technologies, ORIGINAL ARTICLE Management of Ground-Glass Opacity Lesions Detected in Patients with Otherwise Operable Non-small Cell Lung Cancer Hong Kwan Kim, MD,* Yong Soo Choi, MD,* Kwhanmien Kim, MD,* Young Mog

More information

Imaging Decisions Start Here SM

Imaging Decisions Start Here SM Owing to its high resolution and wide anatomic coverage, dynamic first-pass perfusion 320-detector-row CT outperforms PET/CT for distinguishing benign from malignant lung nodules, researchers from Japan

More information

Learning Objectives. 1. Identify which patients meet criteria for annual lung cancer screening

Learning Objectives. 1. Identify which patients meet criteria for annual lung cancer screening Disclosure I, Taylor Rowlett, DO NOT have a financial interest /arrangement or affiliation with one or more organizations that could be perceived as a real or apparent conflict of interest in the context

More information

ESTABLISHING DRLs in PEDIATRIC CT. Keith Strauss, MSc, FAAPM, FACR Cincinnati Children s Hospital University of Cincinnati College of Medicine

ESTABLISHING DRLs in PEDIATRIC CT. Keith Strauss, MSc, FAAPM, FACR Cincinnati Children s Hospital University of Cincinnati College of Medicine ESTABLISHING DRLs in PEDIATRIC CT Keith Strauss, MSc, FAAPM, FACR Cincinnati Children s Hospital University of Cincinnati College of Medicine CT Dose Indices CTDI INTRODUCTION CTDI 100, CTDI w, CTDI vol

More information

High Opacification of Hilar Pulmonary Vessels with a Small Amount of Nonionic Contrast Medium for General Thoracic CT: A Prospective Study

High Opacification of Hilar Pulmonary Vessels with a Small Amount of Nonionic Contrast Medium for General Thoracic CT: A Prospective Study Pierre Loubeyre 1 Isabelle Debard 2 Chantal Nemoz 3 Van André Tran Minh 2 Received April 5, 2001; accepted after revision December 28, 2001. 1 Service de Radiologie, l Hôpital Cantonal Universitaire de

More information

Dual-Energy CT: The Technological Approaches

Dual-Energy CT: The Technological Approaches Dual-Energy CT: The Technological Approaches Dushyant Sahani, M.D Director of CT Associate Professor of Radiology Massachusetts General Hospital Harvard Medical School Email-dsahani@partners.org Disclosure

More information

Purpose. Methods and Materials

Purpose. Methods and Materials Thin-section CT findings in peripheral lung cancer of 3 cm or smaller: are there any characteristic features for predicting tumor histology or do they depend only on tumor size? Poster No.: C-1893 Congress:

More information

Utility of 18 F-FDG PET/CT in metabolic response assessment after CyberKnife radiosurgery for early stage non-small cell lung cancer

Utility of 18 F-FDG PET/CT in metabolic response assessment after CyberKnife radiosurgery for early stage non-small cell lung cancer Utility of F-FDG PET/CT in metabolic response assessment after CyberKnife radiosurgery for early stage non-small cell lung cancer Ngoc Ha Le 1*, Hong Son Mai 1, Van Nguyen Le 2, Quang Bieu Bui 2 1 Department

More information

Pulmonary Embolism. Thoracic radiologist Helena Lauri

Pulmonary Embolism. Thoracic radiologist Helena Lauri Pulmonary Embolism Thoracic radiologist Helena Lauri 8.5.2017 Statistics 1-2 out of 1000 adults annually are diagnosed with deep vein thrombosis (DVT) and/or pulmonary embolism (PE) About half of patients

More information

Low Dose Era in Cardiac CT

Low Dose Era in Cardiac CT Low Dose Era in Cardiac CT DIANA E. LITMANOVICH, MD Department of Radiology Beth Israel Deaconess Medical Center Harvard Medical School Disclosures Neither I nor my immediate family members have a financial

More information

Automatic Patient Centering for MDCT: Effect on Radiation Dose

Automatic Patient Centering for MDCT: Effect on Radiation Dose Patient Centering for MDCT CT Imaging Original Research Jianhai Li 1 Unni K. Udayasankar 1 Thomas L. Toth 2 John Seamans 2 William C. Small 1 Mannudeep K. Kalra 1,3 Li J, Udayasankar UK, Toth TL, Seamans

More information

Fused monochromatic imaging acquired by single source dual energy CT in hepatocellular carcinoma during arterial phase: an initial experience

Fused monochromatic imaging acquired by single source dual energy CT in hepatocellular carcinoma during arterial phase: an initial experience Original Article Fused monochromatic imaging acquired by single source dual energy CT in hepatocellular carcinoma during arterial phase: an initial experience Shun-Yu Gao, Xiao-Peng Zhang, Yong Cui, Ying-Shi

More information

Doubling Time of Thymic Epithelial Tumors Correlates With World Health Organization Histopathologic Classification

Doubling Time of Thymic Epithelial Tumors Correlates With World Health Organization Histopathologic Classification Cardiopulmonary Imaging Original Research Jeong et al. Thymic Epithelial Tumors Cardiopulmonary Imaging Original Research JOURNAL CLUB Dong Young Jeong 1 Kyung Soo Lee 1 Myung Jin Chung 1 Jae Ill Zo 2

More information

Estimating Iodine Concentration from CT Number Enhancement

Estimating Iodine Concentration from CT Number Enhancement Estimating Iodine Concentration from CT Number Enhancement Rosemary Eaton, Andrew Shah, Jane Shekhdar Medical Physics, Mount Vernon Hospital CT Users Group 4 th October 212, Edinburgh Summary Background

More information

Missed Pulmonary Embolism on Abdominal CT

Missed Pulmonary Embolism on Abdominal CT Cardiopulmonary Imaging Original Research Lim et al. Pulmonary Emboli Missed on CT of the Abdomen Cardiopulmonary Imaging Original Research Kun Young Lim 1 Seth J. Kligerman 2 Cheng Ting Lin 2 Charles

More information

Radiological staging of lung cancer. Shukri Loutfi,MD,FRCR Consultant Thoracic Radiologist KAMC-Riyadh

Radiological staging of lung cancer. Shukri Loutfi,MD,FRCR Consultant Thoracic Radiologist KAMC-Riyadh Radiological staging of lung cancer Shukri Loutfi,MD,FRCR Consultant Thoracic Radiologist KAMC-Riyadh Bronchogenic Carcinoma Accounts for 14% of new cancer diagnoses in 2012. Estimated to kill ~150,000

More information

Effect of CT Image Compression on Computer-assisted Lung Nodule Volume Measurement 1

Effect of CT Image Compression on Computer-assisted Lung Nodule Volume Measurement 1 Computer Applications Radiology Jane P. Ko, MD Jeffrey Chang, MD Elan Bomsztyk, BS James S. Babb, PhD David P. Naidich, MD Henry Rusinek, PhD Published online before print 10.1148/radiol.2371041079 Radiology

More information

MEASUREMENT OF EFFECT SOLID TUMOR EXAMPLES

MEASUREMENT OF EFFECT SOLID TUMOR EXAMPLES MEASUREMENT OF EFFECT SOLID TUMOR EXAMPLES Although response is not the primary endpoint of this trial, subjects with measurable disease will be assessed by standard criteria. For the purposes of this

More information

CT angiography techniques. Boot camp

CT angiography techniques. Boot camp CT angiography techniques Boot camp Overview Basic concepts Contrast administration arterial opacification Time scan acquisition during the arterial phase Protocol examples Helical non-gated CTA Pulmonary

More information

NIH Public Access Author Manuscript AJR Am J Roentgenol. Author manuscript; available in PMC 2011 July 6.

NIH Public Access Author Manuscript AJR Am J Roentgenol. Author manuscript; available in PMC 2011 July 6. NIH Public Access Author Manuscript Published in final edited form as: AJR Am J Roentgenol. 2010 September ; 195(3): W221 W228. doi:10.2214/ajr.09.3928. New Response Evaluation Criteria in Solid Tumors

More information

Calcium scoring using 64-slice MDCT, dual source CT and EBT: a comparative phantom study

Calcium scoring using 64-slice MDCT, dual source CT and EBT: a comparative phantom study Int J Cardiovasc Imaging (2008) 24:547 556 DOI 10.1007/s10554-007-9282-0 ORIGINAL PAPER Calcium scoring using 64-slice MDCT, dual source CT and EBT: a comparative phantom study Jaap M. Groen Æ Marcel J.

More information

Pediatric chest HRCT using the idose 4 Hybrid Iterative Reconstruction Algorithm: Which idose level to choose?

Pediatric chest HRCT using the idose 4 Hybrid Iterative Reconstruction Algorithm: Which idose level to choose? Journal of Physics: Conference Series PAPER OPEN ACCESS Pediatric chest HRCT using the idose 4 Hybrid Iterative Reconstruction Algorithm: Which idose level to choose? To cite this article: M Smarda et

More information

Subsolid lung nodules, also termed ground-glass nodules

Subsolid lung nodules, also termed ground-glass nodules ORIGINAL ARTICLE Long-Term Surveillance of Ground-Glass Nodules Evidence from the MILD Trial Silva Mario, MD,* Sverzellati Nicola, MD, PhD,* Manna Carmelinda, MD,* Negrini Giulio, MD,* Marchianò Alfonso,

More information

Growth Pattern Analysis of Murine Lung Neoplasms by Advanced Semi-Automated Quantification of Micro-CT Images

Growth Pattern Analysis of Murine Lung Neoplasms by Advanced Semi-Automated Quantification of Micro-CT Images Growth Pattern Analysis of Murine Lung Neoplasms by Advanced Semi-Automated Quantification of Micro-CT Images Minxing Li 1., Artit Jirapatnakul 2., Alberto Biancardi 2, Mark L. Riccio 3, Robert S. Weiss

More information

Managing Radiation Risk in Pediatric CT Imaging

Managing Radiation Risk in Pediatric CT Imaging Managing Radiation Risk in Pediatric CT Imaging Mahadevappa Mahesh, MS, PhD, FAAPM, FACR, FACMP, FSCCT. Professor of Radiology and Cardiology Johns Hopkins University School of Medicine Chief Physicist

More information

Length Measurements of the Aorta After Endovascular Abdominal Aortic Aneurysm Repair

Length Measurements of the Aorta After Endovascular Abdominal Aortic Aneurysm Repair Eur J Vasc Endovasc Surg 18, 481 486 (1999) Article No. ejvs.1999.0882 Length Measurements of the Aorta After Endovascular Abdominal Aortic Aneurysm Repair J. J. Wever, J. D. Blankensteijn, I. A. M. J.

More information

GUIDELINES FOR PULMONARY NODULE MANAGEMENT : RECENT CHANGES AND UPDATES

GUIDELINES FOR PULMONARY NODULE MANAGEMENT : RECENT CHANGES AND UPDATES Venice 2017 GUIDELINES FOR PULMONARY NODULE MANAGEMENT : RECENT CHANGES AND UPDATES Heber MacMahon MB, BCh Department of Radiology The University of Chicago Disclosures Consultant for Riverain Medical

More information