Electrodes (for TransAeris System)

Similar documents
Model 5392 EPG Temporary Pacer

NeuRx Diaphragm Pacing System Patient/Caregiver Instruction Manual

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500)

Device Preparation (all steps to be performed per standard interventional technique)

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500)

Algovita. MRI Procedure Guidelines. Spinal Cord Stimulation System. 201x

NeuRx Diaphragm Pacing System Patient/Caregiver Information and Instruction Manual For Amyotrophic Lateral Sclerosis

Technique Guide KISSloc Suture System

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System

PATIENT PROGRAMMER 37642

SIX PACK ABS Item No INSTRUCTION MANUAL. Read entire manual before operating this product. Use only as directed.

Read this manual before performing an MRI scan on a patient implanted with an Algovita Spinal Cord Stimulation System.

St. Jude Medical 8-Channel Adapter. Clinician's Manual

AWAY Model # RTLAGF-900 REV

Initial placement 24FR Pull PEG kit REORDER NO:

Initial placement 20FR Guidewire PEG kit REORDER NO:

Peritoneal Drainage System

Instructions for Use Reprocessed LASSO Circular Mapping Diagnostic Electrophysiology (EP) Catheter

Instruction Manual Aerogen, Inc. Part No. AG-AL1010 Rev. C

ASEPT. Pleural Drainage System INSTRUCTIONS FOR USE REF LOT STERILE EO. Manufactured for: 824 Twelfth Avenue Bethlehem, PA

Compatible with the following products TENS. Replacement Pads. User Manual. Last revised: V Last revised: V

Phonak PilotOne II. User Guide

Lead and Extension Insertion Tool. Model Clinician's Manual

CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE

Desara TV and Desara Blue TV

There are different types of ICDs:

ASEPT. Pleural Drainage System INSTRUCTIONS FOR USE. Rx only REF LOT. STERILE EO Sterilized using ethylene oxide

PRO-DENSE Bone Graft Substitute The following languages are included in this packet:

The Biomet EBI Bone Healing System. Patient Manual

Stratis INSTRUCTIONS FOR USE. Needle-free Injection System. 0.5mL volume (+/-5%)

MRI GUIDELINES FOR INSPIRE THERAPY

ECG Check Wireless 1- Lead Cardiac Monitor. Rx Use

Micra MC1VR01. MRI procedural information for Micra Model MC1VR01 MR Conditional single chamber transcatheter pacing device (VVIR)

FlexAbs EMS ABDOMINAL STIMULATOR. FlexBody. EMS Body Stimulator INSTRUCTION MANUAL

ASEPT Pleural Drainage System

Lotus transducer Instructions for use

ECG Monitoring, Defibrillation and Synchronized Cardioversion with Hands-Free Electrodes

AspireSR. Essential information about your new device

Mini Pulse Electronic Stimulator

MRI GUIDELINES FOR INSPIRE THERAPY

MODEL EPG SINGLE CHAMBER TEMPORARY EXTERNAL PACEMAKER

Single Use Curlew TM Multiple Biopsy Forceps

For more information visit or contact hearx:

Integra Flowable Wound Matrix

PRO-DENSE BONE GRAFT SUBSTITUTE

Comfortmax Thermax Hot/Cold Water Circulation System. Instructions for Use

Remote control 2 guide

DISCOVER NEW HORIZONS IN FLUID DRAINAGE. Bringing Safety and Convenience to Fluid Drainage Management

Introduction. Follow standard infection control precautions

Quick Reference Guide

Instructions for Use Reprocessed Arthroscopic Shavers

Quick Reference Guide

Pocket Adaptor Kit FOR SPINAL CORD STIMULATION. Tip Cards

Quick Reference Guide

MRI for Patients with MRI-Conditional Pacing System: Radiographers Role. Lawrance Yip DM, DR, QMH

What you should know about your diagnosis of incontinence

Instruction for Use of 3-stage Dilation Balloon Catheter JS-CE-SM-08-01, A/0

ISO INTERNATIONAL STANDARD. Implants for surgery Active implantable medical devices Part 2: Cardiac pacemakers

ImageReady MRI Head Only Guidelines for Spectra WaveWriter Spinal Cord Stimulator System

Medtronic MiniMed Insulin Infusion Pumps

Implants for surgery Active implantable medical devices. Part 7: Particular requirements for cochlear implant systems

ER75 Electro-Acoustic Ear Simulator. Operating Manual

Contra-Indications, Warnings, Cautions & Precautions

Absorbable Woven Polyglycolic Acid Mesh Tube (Absorbable Nerve Conduit Tube) INSTRUCTIONS FOR USE 2 6

The following languages are included in this packet:

Unitron remote control guide

Endorectal Balloon (ERB) Endorectal Balloon (ERB) Instructions for Use

This document is a preview generated by EVS

with Blom-Singer Gel Cap Insertion System

PilotOne II. User Guide

HCS70004P, HCS70004G HCS70004C, HCS70004BL HCS70004DP, HCS70004 AEROMIST COLORS NEBULIZER COMPRESSOR KIT. Instruction Manual

Portable Equine Nebuliser System. User Manual

Yes, out of sight out of mind.

Advisa MRI and Ensura MRI SureScan pacing systems

Surgical Leads. Directions for Use. CAUTION: Federal law restricts this device to sale, distribution and use by or on the order of a physician.

Dual Chamber Temporary External Pacemaker

MRI Procedure Information. For St. Jude Medical MR Conditional Neurostimulation Systems. Clinician's Manual

The VNS Therapy Magnet

ENDO-FUSE INTRA-OSSEOUS FUSION SYSTEM The following languages are included in this packet:

FREQUENTLY ASKED QUESTIONS. Frequently Asked Questions

OPERATING INSTRUCTIONS

Peripherally Inserted Central Catheter & Midline Placement with ECG Confirmation of Tip Placement

Transcutaneous Electrical Nerve Stimulation (TENS)

Compressor Nebulizer. Model UN-014

DARCO MIS FOREFOOT SCREW

Better Post-Op Pain Control Starts Here

Part 1: General requirements

You have a what, inside you?

Charging base guide. A Sonova brand

DRG THERAPY FOR CHRONIC PAIN ACCURATE CLINICAL STUDY FACT SHEET FOR PATIENTS

AXS Catalyst Distal Access Catheter

ISO INTERNATIONAL STANDARD. Implants for surgery Active implantable medical devices Part 2: Cardiac pacemakers

CP lead resting electrocardiograph

MRI Guidelines for the Axonics Sacral Neuromodulation System

Safety manual for hearing instruments

Pacemaker and ICD Interrogation

Percutaneous Lead Kit. Models 3143, 3146, 3149, 3153, 3156, 3159, 3183, 3186, Clinician's Manual

Transcutaneous Electrical Nerve Stimulation Device GF-3 / GF-3T

Instructions for Use Reprocessed Ethicon ENDOPATH XCEL TM Bladeless Trocar with OPTIVIEW Technology

Transcription:

Surgical Procedures for Implantation of TransLoc Electrodes (for TransAeris System) 1 R L 1 TransAeris System TransLoc Electrode Kit 3 3 TransAeris Patient Kit (FrictionLoc) TransAeris Patient Kit (TransAeris Stimulator) Package Contents The TransLoc electrodes are supplied with the following items: (0) TransLoc Electrodes (1) Surgical Manual Re-Order # 0-1004 1

About This Manual This manual describes the surgical procedures for implantation of TransLoc Electrodes. TransAeris is a percutaneous intramuscular diaphragm stimulator for temporary use in the hospital setting. The system consists of implantable stimulating TransLoc electrode leads, disposable/single-use FrictionLoc connectors (0-100 Patient Kit), and a disposable/single-use portable external stimulator (0-100 Patient Kit). When done prophylactically with another procedure, the implant approach to the diaphragm may be from either the inferior (abdominal) or superior (chest) aspect of the diaphragm surface. The system has four stimulating intramuscular TransLoc electrodes to be implanted into the diaphragm for motor point diaphragm stimulation. Two stimulating TransLoc electrodes shall be placed into each hemi-diaphragm. TransLoc electrodes are tunneled through two percutaneous exit sites on the respective lateral chest region. A single left and right FrictionLoc connector (Patient Kit) will provide an electrical interface from the TransLoc electrodes to a patient cable. The patient cable with left (blue) and right (green) identifiers (Patient Kit) is integrated into the TransAeris stimulator (Patient Kit). TransAeris stimulator has a user interface for clinical control. Intended Use TransAeris is a percutaneous intramuscular diaphragm stimulator intended for patients at risk of or on prolonged positive pressure mechanical ventilation. Contraindications None TransAeris is indicated for use in the prevention and treatment of ventilator-induced diaphragm dysfunction (VIDD).

YWarnings MR MR Use only under the direction of a physician. The TransAeris stimulator is electrically powered and may produce tissue damage or electrical hazard if improperly used. The device has accessible controls for clinical staff and NO patient-accessible controls. Do NOT attempt to open the TransAeris stimulator case or attempt any unintended modifications as this will cause a failure in the TransAeris stimulator functionality. Use of TransAeris could interfere with some medical equipment. Some medical equipment could interfere with the use of TransAeris. Consult the User Manual before having any of the following: Implanted cardiac pacemaker or defibrillator. Use of the TransAeris stimulator may interfere with these devices. Surgery. Use of high-frequency surgical equipment may cause burns where the electrode leads pass through the skin. Such equipment may damage the TransAeris stimulator. Disconnect the TransAeris stimulator when high-frequency surgical equipment is in use. Magnetic Resonance Imaging (MRI) test. The TransLoc electrode is MR unsafe. Do not perform a MRI test while implanted with the TransLoc electrodes or remove the TransLoc electrodes from the patient before a MRI test. Magnetic Resonance Imaging (MRI) test. The TransAeris stimulator, FrictionLoc connector, and surface electrode are MRI Unsafe. Remove these components from the patient before a MRI test. Use of external electrical stimulation such as transcutaneous electrical nerve stimulation (TENS) should not be done in the chest area near the electrode leads. Unwanted diaphragm contraction could occur. Clinicians should avoid accidental contact between connected but unused applied parts (cable or leads) and other conductive parts including those connected to earth ground or any device with the ground symbol. Safety has not been established for the use of the device during pregnancy. It should not be used in patients with epilepsy. CARDIAC INTERFERENCE. Before conditioning, test interference with cardiac rhythm. Monitor electrocardiogram (ECG) while stimulating at maximal settings. If interference is observed, decrease stimulation settings below level of interaction, turn off identified electrodes, or remove identified electrodes. Do NOT come in contract with TransLoc electrodes during emergency defibrillation. It may lead to electric shock to caregivers. ELECTROMAGNETIC INTERFERENCE WARNING: Some electrically powered equipment gives off electromagnetic waves which could interfere with TransAeris systems. When using your TransAeris system around electrical equipment, check the TransAeris stimulator screen to make sure the TransAeris system is working. Do follow the electromagnetic compatibility (EMC) information provided. The TransAeris stimulator needs special precautions regarding EMC. To reduce the possibility of interference on the TransAeris stimulator from other electrical equipment or the TransAeris stimulator effecting other electrical equipment, do not use cables or accessories with the TransAeris stimulator other than those specified. RF COMMUNICATION WARNING: Portable and mobile RF communication equipment may affect medical electrical equipment. Ensure proper function of TransAeris when using around such equipment. 3

YWarnings Continued o ELECTRO-STATIC DISCHARGE (ESD): After the TransLoc electrode has been implanted but not connected to the FrictionLoc connector, use caution when handling the electrode leads. Before touching the electrode leads, touch the patient to equalize the electrostatic potential. FLAMMABILITY WARNING: Do NOT use TransAeris system in an oxygen enriched environment, such as a hyperbaric oxygen chamber, or near a flammable anesthetic mixture with air, oxygen, or nitrous oxide. This could cause a fire or explosion.! Precautions The TransLoc electrodes have been carefully designed and tested to ensure reliability during normal use. To avoid damage to the TransLoc electrodes, observe the following precautions. The TransAeris system is designed for single-patient use. Dispose of the device and all components when finished using on a patient. Do NOT reuse. Reuse may lead to transmission of infection. TransLoc leads, improper connection, or fracture of leads may result in failure of the TransAeris stimulator. Inspect exiting electrode leads for damage before use. Possible Adverse Effects Possible adverse effects from the use of TransAeris system may include: Cardiac interaction Lead breakage Unretrieved device fragment Electrode dislodgement Skin infection Skin sensitivity due to adhesive Pain or discomfort due to stimulation 4

Symbols Explanation of symbols Y M h g H STERILE EO STERILIZE -0 Cl +54 C p L C0086 P MR o The Warning symbol precedes warning information that mitigates a risk that is not obvious to the operator. Indicates that a potentially hazardous situation which, if not avoided, could result in harm to the operator or patient. Powered equipment indicates physiological effects not obvious to the user that can cause harm. The Caution symbol appears next to precautionary information when the intention is solely to inform. Indicates that a potentially hazardous situation which, if not avoided, may result in minor or moderate personal injury or property damage. This word is used to also alert against unsafe practices. The Manufacturer symbol appears next to the manufacturer s name and address. The Reference symbol appears preceding the part number for the device. The part number is a unique numeric identifier for the device. The Lot symbol appears preceding the lot number for a device. Devices manufactured at the same time using identical material and parts will share a common lot number. The Use Until symbol appears on devices that have an indication of the date by which the device should be used. The date is expressed as the year and month, with the month referring to the end of the month. The Sterile symbol and the EO method of sterilization symbol appear on devices that have undergone an ethylene-oxide gas sterilization process and are provided sterile The Do not Re-sterilize symbol appears on devices that are supplied sterile to indicate that the device may not be re-sterilized. The Do not Re-use symbol appears on devices that are suppled sterile to indicate that the device is for single-use and may not be used again. The Temperature Limits symbol appears on packages of devices as an indication of the storage and transit temperature limits. The Keep Dry symbol appears on all packages of devices requiring to protect the packaging from potential damage. The Don t Use If Packing Damaged symbol appears on all packages of devices requiring to dispose of the device if the packaging has suffered damage. The Regulatory Marking of Conformity symbol indicates that the device meets Medical Device Directive 93/4/EEC. This has been certified by notified body number 0086. The European Community Representative symbol indicates the identification of the authorized representative for the distribution of devices into the European community. MR Unsafe. A device that is known to pose hazards in all MR environments. ESD sensitive device. 5

Surgical Instructions INFERIOR IMPLANT During a laparotomy with a midline incision for patients such as Liver Transplant, Esophagectomy, Gastrectomy, or Exploratory Laparotomy from Trauma. Hold a retractor up on the abdominal wall to see the left and right diaphragm. Place two electrodes into the right hemi diaphragm lateral to the central tendon. The blue polypropylene sutures are then cut to remove the curved needles from the distal end of the electrodes. The electrodes are externalized by pushing the percutaneous access needles through the abdominal wall through the right upper quadrant. Adequate electrode length remains near the diaphragm so that there is not any tension on the lead during contraction. On the patient s left diaphragm two electrodes are placed lateral to the edge of the pericardium, where you can see the heart is beating as the phrenic nerve comes in laterally on the left diaphragm. Figure 1 The blue polypropylene sutures are then cut to remove the curved needles from the distal end of the electrodes. The two electrodes are externalized by pushing the percutaneous access needles through the lateral aspect of the left upper abdomen below the costal margin. Adequate electrode length remains near the diaphragm so that there is not any tension on the lead during contraction. SUPERIOR IMPLANT During an open median sternotomy two electrodes are implanted on the right hemi diaphragm and two electrodes on the left hemi diaphragm. They are implanted just lateral to where the phrenic nerve comes into the central tendon. The blue polypropylene sutures are then cut to remove the curved needles from the distal end of the electrodes. Each electrode is externalized so that it exits the chest in as direct a path as possible to the percutaneous exit site to allow for eventual easier removal. This is done by using the percutaneous access needle to bring the lead out through the skin in the desired location. For procedures with temporary cardiac pacing, two electrodes exit on each side above and lateral to the temporary Figure cardiac pacing wires. Adequate electrode length remains near the diaphragm so that there is not any tension on the lead during contraction. 6

Cut 1 3 After the TransLoc electrodes have been implanted into the diaphragm and tunneled through the skin, the external end of the electrodes requires preparation before it can be connected to the FrictionLoc connector. The suture (1) between the tunneling needle () and the conductive pin (3) must be cut. Figure 3 Cut the suture approximately halfway between the tunneling needle and the conductive pin, leaving the silicon protective tube covering the conductive pin. 4 The silicon protective tube (4) will remain on the conductive pin until it is ready to use in the ICU. Figure 4 The external wires are fixated on the skin by looping them and suturing them. Figure 5 7

M P h 300 Artino Street Oberlin, Ohio 44074 U.S.A. www.synapsebiomedical.com Tel: + 1-888-767-3770 extension 137 + 1-440-774-488 extension 137 Fax: + 1-440-774-57 Synapse Biomedical - Europe 7 Rue de la Libération 95880 Enghien Les Bains, France France and other Countries Tel: +33 (0) 1 34 16 49 11 Fax: +33 (0) 1 74 18 08 19 Australian Sponsor Emergo Australia Level 0, Tower II Darling Park 01 Sussex Street Sydney, NSW 000 Australia TransAeris, TransLoc, and FrictionLoc are trademarks or Registered trademarks of Synapse Biomedical, Inc. in the U.S. The TransAeris System and components are covered by one or more U.S. patents. Synapse Biomedical Inc. 017 All Rights Reserved 77-100-EN (REV A) 8 0086