Numerical Simulation of Blood Flow in the System of Human Coronary Arteries with and without Bypass Graft

Similar documents
NUMERICAL STUDY OF PULSATILE BLOOD FLOW IN THE CORONARY SYSTEM WITH THE RCA BYPASS GRAFT

Numerical Simulation of Blood Flow in the System of Human Coronary Arteries with Stenosis

EFFECT OF BRANCHINGS ON BLOOD FLOW IN THE SYSTEM OF HUMAN CORONARY ARTERIES. Benchawan Wiwatanapataphee. Yong Hong Wu. Thanongchai Siriapisith

FOR many decades, cardiovascular disease has been one of

Non-Newtonian pulsatile blood flow in a modeled artery with a stenosis and an aneurysm

Design and Simulation of Blocked Blood Vessel for Early Detection of Heart Diseases

JADAVPUR UNIVERSITY & 2 SCHOOL OF BIOSCIENCE AND ENGINEERING ABHIRUP ROY CHOUDHURY 1, KRITTIKA DASGUPTA 2, ABHIJIT CHANDA 1,2, DEBABRATA NAG 1

A computational fluid dynamics simulation study of coronary blood flow affected by graft placement

Numerical Simulation of Blood Flow through Asymmetric and Symmetric Occlusion in Carotid Artery

CFD Analysis of Pulsatile Flow and Non-Newtonian Behavior of Blood in Arteries

Arteriovenous Graft Modeling and Hemodynamic Interpretation

Blood flow in vessels with artificial or pathological geometrical changes

Blood Flow Simulation toward Actual Application at Hospital

Simulations of pulsatile blood flow in tapered S-shaped inplane and out-of-plane coronary arteries

A Review: Hemodynamics of Cerebral Aneurysm with Mathematical Modeling

Numerical simulations of fluid mechanical interactions between two abdominal aortic branches

Using Computational Fluid Dynamics Model to Predict Changes in Velocity properties in Stented Carotid Artery

Simulations of the blood flow in the arterio-venous fistula for haemodialysis

Contents 1 Computational Haemodynamics An Introduction 2 The Human Cardiovascular System

Assessment of the Effects of Increasing Levels of Physiological Realism in the Computational Fluid Dynamics Analyses of Implanted Coronary Stents

54. Simulation and research on the influence of the shape and the geometrical parameters of a blood vessel bypass graft upon hemodynamics

Wall Shear Stress Distribution in Patient Specific Coronary Artery Bifurcation

Effects of Non-Newtonian Behavior of Blood on Wall Shear Stress in an Elastic Vessel with Simple and Consecutive Stenosis

STUDY OF FLOW PHENOMENA IN AORTIC DISSECTION

Simulation of Blood Flow Coronary Artery with Consecutive Stenosis and Coronary-Coronary Bypass

Mathematical and Computational study of blood flow through diseased artery

Post-conditioning. P a g e 1. To my Thesis Committee,

CPM Specifications Document Aortic Coarctation: Exercise

Blood flow in S-shaped in-plane and out-of-plane coronary arteries

Numerical Study on Vascular Grafts Prototypes

Analysis of the effects of plaque deposits on the blood flow through human artery

Calculation of the Wall Shear Stress in the case of an Internal Carotid Artery with stenoses of different sizes

Refinements in Mathematical Models to Predict Aneurysm Growth and Rupture

Estimation and Comparison of T Graft Versus Conventional Graft for Coronary Arteries

Effects of surface geometry and non-newtonian viscosity on the flow field in arterial stenoses

CPM Specifications Document Aortofemoral Normal:

4D model of hemodynamics in the abdominal aorta

Numerical analysis of blood flow in human abdominal aorta

Asymmetric flows of non-newtonian fluids in symmetric stenosed artery

Hematocrit Level on Blood flow through a Stenosed Artery with Permeable Wall: A Theoretical Study

A Two-layered Model for the Analysis of Arterial Rheology

Research Article Hemodynamic Features in Stenosed Coronary Arteries: CFD Analysis Based on Histological Images

A Review of Study of the Effects of Plaque Deposits on the Blood Flow through Human Artery

Simulation of blood flow through endovascular prosthesis in patients with Abdominal Aortic Aneurysm

Extraction and FSI modeling of Left coronary artery structure from patient s CTA images

Mathematical Modeling of Bingham Plastic Model of Blood Flow Through Stenotic Vessel

PHYSIOLOGICAL PULSATILE WAVEFORM THROUGH AXISYMMETRIC STENOSED ARTERIES: NUMERICAL SIMULATION

3D Modeling of Plaque Progression in the Human Coronary Artery

The effect of the LVAD connecting point on the hemodynamics in the aortic arch BMTE 09.16

ISSUES ON COMPUTATIONAL MODELING FOR COMPUTATION-AIDED DIAGNOSIS 臨床診断支援ツールのための計算力学モデリング

Study of Newtonian and Non-Newtonian Effect of Blood Flow in Portal Vein in Normal and Hypertension Conditions using CFD Technique

Non-Newtonian blood flow in human right coronary arteries: Transient simulations

CFD Study of the Blood Flow in Cerebral Aneurysms Treated with Flow Diverter Stents

CPM Specifications Document Aortofemoral Normal:

BLOOD FLOW THROUGH A COMPOSITE STENOSIS IN CATHETERIZED ARTERIES INTRODUCTION

A Multiphysics Simulation of a Healthy and a Diseased Abdominal Aorta

CFD Challenge: Simulation of Hemodynamics in a Patient-Specific Aortic Coarctation Model

Comparison of Stent Designs using Computational Fluid Dynamics

COMPUTER SIMULATION OF BLOOD FLOW IN ARTERIES AFFECTED BY MULTIPLE ANEURYSM

Mathematical modeling of atherosclerotic plaque formation coupled with a non-newtonian model of blood ow

Exploring Blood Flow Dynamics Underlying Pathogenesis of Splenic Artery Aneurysms

Identification of Atherosclerotic Lesion-Prone Sites through Patient-Specific Simulation of Low-Density Lipoprotein Accumulation

Studying the Flow Dynamics Within Endografts in Abdominal Aortic Aneurysms

FLUID MECHANICAL PERTURBATIONS INDUCED BY STENT IMPLANTATION: A NUMERICAL STUDY

Correlations of coronary plaque wall thickness with wall pressure and wall pressure gradient: A representative case study

Computational medical imaging and hemodynamics framework for functional analysis and assessment of cardiovascular structures

A Computational Fluid Dynamics Study on Bidirectional Glenn Shunt Flow with an Additional Pulsatile Flow Through a modified Blalock-Taussig Shunt

Computational design of Intracranial Stent using 3D visualization system

Computational Fluid Dynamics Analysis of Blood Flow in Human Aorta

Conference Paper Mathematical Modeling of Atherosclerotic Plaque Formation Coupled with a Non-Newtonian Model of Blood Flow

A numerical study on the effect of hematocrit on hemodynamic characteristics in arteriovenous graft

Vascular reconstruction: CFD predictions of bypass graft haemodynamics

Computational Fluid Dynamics Analysis of Blalock-Taussig Shunt

Simulation of structure - fluid interaction in left side of human heart

The Study of Abdominal Aortic Aneurysm Rupture Risk using Fluid-Structure Interaction

Simulation of Physiological Non-Newtonian Blood Flow through 3-D Geometry of Carotid Artery with Stenosis

The Effects of Aortic Stenosis on the Hemodynamic Flow Properties using Computational Fluid Dynamics

Is a Flat Inlet Profile Sufficient for WSS Estimation in the Aortic Arch?

Universidad Pontificia Bolivariana

Closed-loop CFD Model of the Self-Powered Fontan Circulation for the Hypoplastic Left Heart Syndrome

Flow Analysis with Stent Placement in the Cerebral Aneurysm

History of Vascular Modelling. William Harvey discovery of the circulation 1628

The relative effects of arterial curvature and lumen diameter on wall shear stress distributions in human right coronary arteries

Computational Analysis on Commercially Available Stent Designs

NUMERICAL SIMULATION OF EFFECTS OF REYNOLDS NUMBER ON NON-NEWTONIAN BLOOD FLOW WITH SPIRAL COMPONENT THROUGH A REGULAR STENOSED ARTERY

UNIVERSITY OF CINCINNATI

Non-axisymmetric Flow Development in Pulsatile Blood Flow through an Aneurysm

BLOOD FLOW ANALYSIS OF STA-MCA ANASTOMOSIS USING CFD

Modeling Flow Characteristics in Carotid Artery Bifurcation Afflicted with Atherosclerotic Plaques

A Multiphysics Simulation of a Healthy and a Diseased Abdominal Aorta

FSI Analysis of Diseased Coronary using Patient Specific Data

Numerical investigation on the blood flow characteristics considering the axial rotation in stenosed artery

A 1D lumped-parameter/3d CFD approach for pressure drop in the Aortic Coarctation

The study on hemodynamic effect of series type LVAD on aortic blood flow pattern: a primary numerical study

Computational simulation of 4D blood flow dynamics of the thoraco-abdominal aorta: prediction of long-term changes in aneurysm morphology

BLOOD FLOW VISUALISATION THROUGH CAROTID BIFURCATION USING ANSYS CFD

ANALYSIS OF FLUID-STRUCTURE INTERACTION IN ABDOMINAL AORTIC ANEURYSM WITH HIGH AND NORMAL BLOOD PRESSURE

Computational comparison between Newtonian and non-newtonian blood rheologies in stenotic vessels

Flow in re-stenosed artery after angioplasty

EVALUATION OF ABDOMINAL AORTIC ANEURYSM WALL STESS BASED ON FLOW INDUCED LOAD

Transcription:

Numerical Simulation of Blood Flow in the System of Human Coronary Arteries with and without Bypass Graft BURASKORN NUNTADILOK 1, BENCHAWAN WIWATANAPATAPHEE 1 MEECHOKE CHUEDOUNG 1, THANONGCHAI SIRIAPISITH 2 1 Department of Mathematics, Faculty of Science, Mahidol University, Bangkok, Thailand 2 Department of Radiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand Corresponding author: g5136161@student.mahidol.ac.th, scbww@mahidol.ac.th Abstract: In this paper, we aim to present a three-dimensional simulation of a pulsatile blood flow in the system of human coronary arteries. We investigate the behavior of blood flow through a stenosed right coronary arteries (RCA) with and without bypass graft. The computational domains, constructed and based on real domain, consist of the aorta, the left and the right coronary arteries, and a graft vessel. Blood is considered as an incompressible non-newtonian fluid. The governing equations are the continuity equation and the Navier-Stokes equations together with pulsatile boundary conditions. The solution of governing equations is solved by using finite element method. The results show that higher degree of blockage of the RCA gives higher drop of blood pressure at the stenosis region, and bypass surgery can improves the blood pressure. Key Words: blood flow, bypass graft, coronary artery, incompressible non-newtonian fluid, pulsatile, stenosis. 1 Introduction In present time, almost one fourth of human death are caused by ischaemic heart disease (IHD) and stroke and other cerebrovascular disease, especially in the middle-income and high-income countries. IHD, or called coronary artery disease (CAD), is a major cause of human death in the world. In 2008, the World Health Organization (WHO) had reported the list of the top 10 causes of death in the world [1]. There are 7.25 million men who died because of IHD which is 12.8%, the highest percentage of deaths in the world. To deal with this disease, many surgery procedures have been invented. A coronary artery bypass grafting (CABG) is a technique has been widely used for patients with severe coronary artery diseases. However, up to 25% of grafts fail within one year and up to 50% fail within ten years after surgery [3]. It is believed that this failure depends on the abnormal flow of blood. To overcome the problem of blood flow in the stenosed coronary arteries, many researchers have studied the blood flow behavior in either the right coronary artery (RCA) or the left coronary artery (LCA) by using experimental and numerical studies [4, 11, 12]. Due to morality and ethics, the experimental research on real human body is impracticable. Mathematical modeling and numerical simulation are thus used for understanding the phenomena involved in vascular disease. The problem of stenosis was received attention from many researchers. Blood flow was simulated in a single tube with stenotic region [8, 10]. To understand the behavior of blood in a vessel with bypass graft, the blood flow was simulated in a straight tube with graft [2, 6]. Wiwatanapataphee et al.(2006) investigated the behavior of blood flow in a stenosed RCA with a bypass graft [5]. The result shows that blood pressure drops dramatically in stenosis area and high wall shear stress occurs around the stenosis site. However, it has been recognized that the results obtained from unrealistic computational domain may not be use for treatment. The three-dimensional realistic geometry which mimic human blood vessel was constructed and studied [7, 14]. Chuchard et al.(2011), studied blood flow through the system of coronary arteries with diseased left anterior descending [13]. Their computational domain consists of the base of the aorta, the RCA and the LCA. The result shows that the blood flow with high speed and the pressure rapidly drops in the area of stenosis. In this work, we simulate a non-newtonian pulsatile blood flow in the system of human coronary arteries with and without bypass graft. Figure 1 illustrates a computational domain used in this study. It consists of the ascending part of the aorta, the RCA with a bypass graft and the LCA. The effects of stenosis severity and bypass graft on the pressure distribution are investigated. ISBN: 978-1-61804-094-7 43

Figure 1: A Computational domain (left) which are constructed from a real domain (right). In a square box, the stenosis in the RCA is shown. 2 Governing equations and Boundary conditions In this study, blood is assumed as an incompressible non-newtonian fluid. The motion of blood flow is governed by the continuity equation and the Navier- Stokes equations, which can be expressed in vector notation as follows: u = 0, (1) u t + (u )u = 1 ρ σ, (2) where u is the blood velocity vector in the lumen region, ρ is blood density and σ is the total stress tensor which is defined by σ = pi + η( γ)[ u + ( u) T ], (3) where p is the blood pressure. η and γ denote the viscosity of blood and shear rate, respectively. In this work, the relation between η and γ are described by Carreau s shear-thinning model, namely, η = η + (η 0 η ) [ 1 + (λ γ) 2] (n 1)/2, (4) where η, η 0, λ, and n are parameters and the shear rate defined by γ = 2tr( 1 2 ( u + ( u)t )) 2. (5) As a cyclic nature of heart pump, the pulsatile behavior of blood flow is considered. We assume that, in cardiac cycle, there has no difference of time variation. Therefore, the pulsatile pressure and flow rate can be expressed by the functions p(t) = p(t + nt ) and Q(t) = Q(t + nt ) for n = 0, 1, 2, 3,... and T is the cardiac period [5]. Mathematically, the pulsatile pressure p(t) and flow rate Q(t) can be expressed by the truncated Fourier series: p(t) = p + Q(t) = Q + 4 k=1 αncos(kωt) p + β p ksin(kωt), (6) 4 αn Q cos(kωt) + β Q k sin(kωt), (7) k=1 where ω = 2π is the angular frequency with the period T, p and Q are the mean pressure and the mean T flow rate, respectively. The values of p, Q, α Q n, βn Q, αn, p and βn p are as shown in Table 1. In Figure 2, on the inflow surface Γ aorta of aorta, we let the pulsatile velocity condition is u n (t) = Q(t) A, (8) where A is the surface area of inlet boundary. On the outflow surfaces including Γ aorta 1, Γ aorta 2, Γ aorta 3, Γ aorta 4, Γ RCA 1, Γ RCA 2, Γ RCA 3, Γ RCA 4, Γ LCA 1, and Γ LCA 2, we impose the corresponding pulsatile pressure condition, i.e., p(t) = p 0 (t), η( u + ( u) T ) 2. (9) No-slip condition is applied to the outer arterial wall. ISBN: 978-1-61804-094-7 44

Table 1: Values of the parameters α Q n, β Q n, α p n and β p n Vessel n α Q n β Q n α p n β p n Aorta 1 1.7048-7.5836 8.1269-12.4156 Q = 5.7222 2-6.7035-2.1714-6.1510-1.1072 p = 97.2222 3-2.6389 2.6462-1.333-0.3849 A = 6.862712 4 0.7198 0.2687-2.9473 1.1603 LCA 1 0.1007 0.0764-3.3107-2.2932 Q = 0.1589 2-0.0034-0.0092-9.8639 8.0487 p = 65.9722 3 0.0294 0.0337 3.0278 3.8009 4 0.0195-0.0129 2.2476-3.2564 RCA 1 0.0393 0.0241 5.9369 3.6334 Q = 0.0896 2-0.0360 0.0342-11.199 2.1255 p = 65.3333 3-0.0131 0.0026-2.2778-3.7528 4-0.0035-0.0041 2.7333-0.6375 In summary, the blood flow in the system of human coronary arteries is governed by the following boundary value problem. BVP: Find u and p such that equations (1)-(2) and all boundary conditions are satisfied. 3 Numerical Example In this study, we have simulated the three-dimensional blood flow in the stenosed coronary artery with and without bypass graft. The example under investigation is the system of human coronary arteries including the ascending part of the aorta, the RCA in which the stenosis presents at the proximal part, and the LCA. Figure 3 shows two examples of domain meshes where the area of the aorta inlet surface, A, is about 6.86 cm 2. To investigate the effect of the stenosis severity, we study the pressure distribution along the arterial axis of the stenosed RCA during a cardiac cycle for the cardiac period, T, is 0.8 s. Four different degrees of stenosis including 39.13%, 49.95%, 62.69% and 71.85% are chosen. Finite element method based on COMSOL multiphysics was used to solve the problem of blood flow. The results indicate that the stenosis has a significant effect on blood pressure. We can explain this effect by comparing the pressure profile along the RCA axis as shown in Figure 4. It is noted that the blood pressure drops more the higher the stenosis is. Remarkably, pressure drops a lot when the narrowing of the artery is more than 50 percent. To study how the coronary artery bypass grafting can improve the blood flow, the pressure distribution in the system of coronary arteries having 71.85% stenosis at the proximal part of the RCA is considered. Systolic pressure and diastolic pressure obtained from the model without and with bypass graft are shown in Figure 6 and Figure 7, respectively. Under the severe condition of the stenosis, abnormal pattern of pressure occurs. A high pressure drop causes an decrease in blood pressure in the stenosed artery. The model with a bypass graft causes an increase in blood pressure to the normal pressure. Figure 5 provides a comparison between the pressure along the axis of normal RCA and the axis of the 71.85% stenosed RCA with bypass graft. 4 Conclusion Three-dimensional blood flow in the system of human coronary arteries with and without bypass graft is simulated. The effects of stenosis severity and bypass grafting on the blood pressure in the stenosed artery are investigated. The results shows that stenosis and bypass grafting have significant effects on the blood pressure. Higer degree of stenosis severity generates larger drop of the pressure. This causes an decrease of pressure in the stenosed artery. Bypass grafting can improve the blood pressure. Acknowledgements: The research is supported by Faculty of Science and Graduate school, Mahidol University, Thailand. ISBN: 978-1-61804-094-7 45

Figure 2: Inlet and outlet surfaces of the computational models : a model without a bypass graft, a model with a bypass graft. Figure 3: Domain meshes of the computational models: the model without a bypass graft, the model with a bypass graft. References: [1] World Health Organization, The top 10 causes of death, [Online; accessed 2008], www.who.int/mediacentre/factsheets/fs310/en/ [2] C. Bertolotti and V. Deplano, Three-dimensional numerical simulations of flow through a stenosed coronary bypass, Journal of Biomechanics, 33, 2000, pp. 1011 1022. [3] Y. Papaharilaou, D.J. Doorly and S.J. Sherwin, The influence of out-of-plane geometry on pulsatile flow within a distal end-to-side anastomosis, Journal of Biomechanics, 35(9), 2002, pp. 1225 1239. [4] J. Chen and X.Y. Lu, Numerical investigation of the non-newtonian pulstile blood flow in a bifurcation model with a non-planar branch, Journal of Biomechanics, 39, 2006, pp. 818 832. [5] B. Wiwatanapataphee, D. Poltem, Y.H. Wu and Y. Lenbury, Simulation of pulatile flow of blood in stenosed coronary artery bypass with graft, Mathematical Biosciences and Engineering, 3, 2006, pp. 371 383. [6] E. Shaik, K.A. Hoffmann and J.F.Dietiker, Numerical simulation of pulsatile non-newtonian flow in an end-to-side anastomosis model, Simulation Modelling Practice and Theory, 16, 2008, pp. 1123 1135. ISBN: 978-1-61804-094-7 46

Figure 4: Pressure profile along the stenosed RCA having different degree of stenosis including 0% (the normal RCA), 39.13%, 49.95%, 62.69% and 71.85% at two different times: the peak of systole, the peak of diastole. Figure 5: Pressure profile along the RCA axis at the peak of systole (solid line) and the peak of diastole (dashed line), obtained from the model having 71.85% stenosed RCA with a bypass graft and the normal RCA. [7] J.V. Soulis, G.D. Giannoglou, Y.S. Chatzizisis, K.V. Seralidou, G.E. Parcharidis and G.E. Louridas, Non-Newtonian models for molecular viscosity and wall shear stress in a 3D reconstructed human left coronary artery, Medical Engineering & Physics, 30, 2008, pp. 9 19. [8] S.U. Siddiqui, N.K. Verma, S. Mishra and R.S. Gupta, Mathematical modelling of pulsatile flow of Casson s fluid in arterial stenosis, Applied Mathematics and Computation, 210, 2009, pp. 1 10. [9] J. Janela, A. Moura and A. Sequeira, A 3D non- Newtonian fluid-structure interaction model for blood flow in arteries, Journal of Computational and Applied Mathematics, 234, 2010, pp. 2783 2791. [10] S.U. Siddiqui, N.K. Verma and R.S. Gupta, A mathematical model for pulsatile flow of Herschel-Bulkley fluid through stenosed arteries, e-journal of Science and Technology, 5(4), 2010, pp. 49 66. [11] A.D. Anastasiou, A.S. Spyrogianni, K.C. Koskinas, G.D. Giannoglou and S.V. Paras, Experimental investigation of the flow of a blood analogue fluid in a replica of a bifurcated small artery, Medical Engineering & Physics, 2011. [12] R. Manimaran, CFD simulation of non- Newtonian fluid flow in arterial stenoses with surface irregularities, World Academy of Science, Engineering and Technology 73, 2011, pp. 957 962. [13] P. Chuchard, T. Puapansawat, T. Siriapisith, Y.H. Wu and B. Wiwatanapataphee, Numerical simulation of blood flow through the system of coronary arteries with diseased left anterior descending, International Journal of Mathematics and Computers in Simulation, 5(4), 2011, pp. 334-341. [14] B. Wiwatanapataphee, Y.H. Wu, T. Siriapisith, and B. Nuntadilok, Effect of branching on blood flow in the system of human coronary arteries, Mathematical BioSciences and Engineering, 9(1), 2012, pp. 199-214. ISBN: 978-1-61804-094-7 47

Figure 6: Pressure profile obtained from the model having 71.85% stenosed RCA without a bypass graft: Systolic pressure in the model, Pressure profile along the RCA axis at the peak of systole (solid line) and the peak of diastole (dashed line). Figure 7: Pressure profile obtained from the model having 71.85% stenosed RCA with a bypass graft: Systolic pressure in the model, Pressure profile along the RCA axis at the peak of systole (solid line) and the peak of diastole (dashed line). ISBN: 978-1-61804-094-7 48