Welch Allyn Connex Vital Signs Monitor 6000 Power Supply Replacement

Similar documents
Geschrieben von: Andrew Optimus Goldberg

Mac mini (PowerPC) Storage Interface Board Replacement

MacBook Pro 15" Unibody Mid 2010 Subwoofer & Right Speaker Replacement

HP Mini 210 Fan Replacement

Sony Ericsson W810I Vibration Cell

Geschrieben von: Mark

Asus Transformer T100 Motherboard

Retina MacBook 2015 Dual Microphone Assembly Replacement

MacBook Pro 15" Core 2 Duo Models A1226 and A1260 ExpressCard Cage Replacement

Xbox 360 S Hard Drive Bracket Replacement

Geschrieben von: Gaetan

Nexus 7 I/O Assembly Cable Replacement

Geschrieben von: Valentina Cerruty

Alcatel One Touch Pop 7 Display Assembly Replacement

MacBook Core 2 Duo Fan Replacement

Canon Powershot A70 Button Flex Assembly Replacement

Geschrieben von: Yadira Jones

Disassembling Sony Ericsson w600i LCD Section

Sony Cyber-shot DSC-HX20V Lens Assembly Replacement

Geschrieben von: Phillip Takahashi

Asus Zenfone 2 Display Assembly

Microsoft Bluetooth Notebook Mouse 5000 Central wheel button switch Fix

How to Repair a MagSafe Connector

Quasar Microwave Capacitor Replacement

N4i Installation Manual. (picture of N4i screen)

A-dec 372L or 572L Dental Light on an A-dec Performer Dental Chair INSTALLATION GUIDE

SlideDriver 50VF. Modbus Controlled VFD Replacement Kit (MX4210, MX4211) REQUIRED TOOLS PARTS WORK SAFELY!

Vital Signs Monitor Series (VSM) Outline Train the Trainer

CIRCULATORY MASSAGER OPERA TING INSTRUCTION HM01-08QI

limbsandthings.com Advanced Female Catheterisation Trainer User Guide For more skills training products visit Limbs & Things Ltd.

Bio Mechanical Hoof Tester Operator s Manual

limbsandthings.com Advanced Catheterisation Trainer User Guide For more skills training products visit Limbs & Things Ltd.

CROSS TRAINING MAGNETIC TREADMILL

Experiment HM-11: Electromyograms (EMG) for Paired Arm Wrestling

1.0 SAFETY WARNINGS 2.0 CONTENTS OF KIT AND RE-ORDER CODES 3.0 SYSTEM SETUP 4.0 PARTS IDENTIFICATION - PHOTOGRAPHIC 5.0 GUIDE TO FITTING 5.

Congratulations on purchasing your new Total Gym

CATHETERIZATION TRAINER ON A STAND

Bowflex Home Gym- PR1000

Parts identification:

Education for self administration of intravenous therapy HOME IV THERAPY. 30 minute - Baxter Pump Tobramycin

OWNER S MANUAL. BODYCRAFT 7699 Green Meadows Dr., Lewis Center, Ohio Tel:

THE TOTALLY WICKED TORNADO NC CONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED TORNADO NC ELECTRONIC CIGARETTE KIT

How to Set Up and Infuse Your TPN

OTAGO LIPOSURG. Compact, powerful system for infiltration and liposuction

User Guide and Operating Manual

How to Rebuild and Replace the Coils in a Mutation X V4 Atomizer

RaySafe i3 INSTALLATION & SERVICE MANUAL

Fitting Guide BEHIND-THE-EAR HEARING INSTRUMENTS. Pico RITE Hearing System

INSTRUCTION MANUAL LEG PRESS (NEW MODEL) OPTION OF K2 GYM

DSI Series Installation

Linear Array Transducer

User Manual & Repair Manual

BLINDED MODE USERS GUIDE SUPPLEMENT

TJF-160F/VF Cleaning and Disinfection Checklist

Optimal. Equipment for the glass professional. T-MAX EVO

Core (machines) Medicine Ball Back Extension

SMV-1 Assembly Manual

INSTRUCTIONS FOR PREPARING AND GIVING AN INJECTION OF ENBREL POWDER

USER S MANUAL QUESTIONS? CAUTION. Visit our website at Model No. PFEVEL33020 Serial No. Serial Number Decal

LET OUR IMAGE ENHANCE YOUR IMAGE. Operating Instructions MedRx Video Portable OtoScope System

Fitting Guide BEHIND-THE-EAR HEARING INSTRUMENTS. Pico RITE Hearing System

SDS 4.0 Tips and Tricks

XTR5 Elliptical Cross Trainer

ROWER 305 OWNER S MANUAL

Advanced Catheterisation Trainer User Guide

SDS 4.0 Reference Guide

weight.detach/bench ITEM NO: 76310

Instructions for Use Enbrel (en-brel) (etanercept) for injection, for subcutaneous use Multiple-dose Vial

Standard VPX Cable Accessories

How to Use ENBREL : Vial Adapter Method

ALPROLIX Coagulation Factor IX (Recombinant), Fc Fusion Protein INSTRUCTIONS FOR USE Do not Do not YOUR KIT CONTAINS:

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plate Aiming Instruments. Part of the 3.5 mm LCP Percutaneous Instrument System.

Experiment HH-3: Exercise, the Electrocardiogram, and Peripheral Circulation

Instructions for Use. For use with. 10 mg vial

insafe System - Directions for Use

The Bowflex Conquest Home Gym Assembly Instructions

Multipower. User Guide E S S E N T I A L S T R E N G T H

1. Abs Triangle of Control Muscle: Upper abdominals Resistance: Body weight Body Connection: Legs

RJA RJA. Welded cabinet with demountable side panels and back panel, IP 20, loading capacity 600 kg

Allergy Reliever. User Manual. AR 1 Series

Nucleus CP810 Sound Processor User Guide

Exercise Library. Exercise Image Description. Air Squats. Assisted Dips. Assisted Pull- Ups

BAYER: KOGENATE FS WITH BIOSET (Recombinant FVIII)

USER MANUAL Rev. 1.15

HumaPen SAVVIO INSULIN DELIVERY DEVICE INSTRUCTIONS FOR USE

Bands. Model : No For Customer Service, please contact:

Round 4: Lower Body Exercises: BOSU Jump Over Squats: Begin with one foot on the BOSU ball and one on the ground. Perform a squat until legs are at 90

Anorectal Transducer User Guide. Type 2050 and Type 2052

BD Eclipse Needle for Luer Lock Syringes - How to Use the BD Eclipse Needle for Luer Lock Syringes 3. Injection 1. Attachment

The following guidelines are applicable to office workers who sit at a desk and/or work on computers.

Owner s Manual. For maximum effectiveness and safety, please read this owner s manual and view the video before using your Total Gym Elite.

CAUTION...2 INSTRUCTION...5 IF-4000 INTERFERENTIAL STIMUATOR CONTROLS AND FUCTIONS...7 HOW TO USE YOUR IF-4000 STIMULATOR...14 ELECTRODES CARE...

3Replacement Transducer Cables

MX SELECT OWNER S MANUAL. Revolutionising Strength Training REGISTER YOUR PRODUCT AT MXSelect. MX_Select.

Baxter, ADVATE Antihemophilic Factor (Recombinant)

CP lead resting electrocardiograph

Instructions for Use. Welcome!

Introduction. Welcome to VibraWav and The New Approach to Therapeutic Exercise

English. Fealite Nasal Pillows System. User Manual

Physical Therapy for Reverse Total Shoulder Replacement

Transcription:

Welch Allyn Connex Vital Signs Monitor 6000 Power Supply Replacement Replace the power supply in a 6000 series Welch Allyn Connex Vital Signs Monitor. Geschrieben von: Sam Lionheart ifixit CC BY-NC-SA de.ifixit.com Seite 1 von 17

EINLEITUNG Use this guide to replace the power supply in your 6000 series Connex vital signs monitor. PLEASE NOTE: This repair guide was developed by the ifixit team based on Welch Allyn's own service manual. Neither ifixit nor this repair guide is endorsed by or affiliated with Welch Allyn. WERKZEUGE: Flathead Screwdriver (1) Phillips #2 Screwdriver (1) Coin (1) Spudger (1) 8" Needle Nose Plier (1) T10 Torx Screwdriver (1) ifixit CC BY-NC-SA de.ifixit.com Seite 2 von 17

Schritt 1 Stand Unplug the AC power connection cable. Schritt 2 Place your thumb and forefinger on the blood pressure (NIBP) hose connector. Squeeze the side tabs until the connector releases. Always grasp the hose by the connector. Do not pull on the hose itself. Pull the connector away from the connector port. ifixit CC BY-NC-SA de.ifixit.com Seite 3 von 17

Schritt 3 Place your thumb and forefinger on the Pulse oximetry (SpO2 or combined SpO2/SpHb) cable connector. Squeeze the side tabs until the connector releases. Always grasp the cable by the connector. Do not pull on the cable itself. Pull the connector away from the connector port. Schritt 4 Grasp the temperature probe and pull it up to remove it from the monitor. ifixit CC BY-NC-SA de.ifixit.com Seite 4 von 17

Schritt 5 Remove the cover of the temperature module by pressing the tab and sliding the cover to the right. Schritt 6 Depress the spring tab on the temperature probe cable connector and withdraw it from the probe port. ifixit CC BY-NC-SA de.ifixit.com Seite 5 von 17

Schritt 7 Remove the flathead screw on the USB networking door. Loosen the captive Phillips #2 screw securing the monitor to the stand. Schritt 8 Holding the monitor securely, open the USB networking door. You may have to lift the monitor slightly to allow the door to swing out from the stand mount. ifixit CC BY-NC-SA de.ifixit.com Seite 6 von 17

Schritt 9 Detach any accessory USB cables from USB ports on the monitor. Schritt 10 Slide the monitor off of the stand tray. ifixit CC BY-NC-SA de.ifixit.com Seite 7 von 17

Schritt 11 Battery Place the monitor upside down on a clean surface. Insert a coin into the slot and push to open. Choose a coin that fits comfortably into the slot. Remove the battery cover. Schritt 12 Use the plastic label to remove the battery from its recess. ifixit CC BY-NC-SA de.ifixit.com Seite 8 von 17

Schritt 13 Rear Housing Open the communications door to access the lower left-hand rear housing screw. Remove the four Phillips #2 screws (labeled 14 in the service manual) from the rear housing. ifixit CC BY-NC-SA de.ifixit.com Seite 9 von 17

Schritt 14 With the handle/alert bar facing you, begin to lift the rear housing from the left side, holding the right side securely. Do not attempt to separate the rear housing from the monitor, it is still attached with several cables. Schritt 15 Support the rear housing while you disconnect the cables in the following steps. ifixit CC BY-NC-SA de.ifixit.com Seite 10 von 17

Schritt 16 Disconnect the fan cable (labeled connector A in the service manual) from its socket in the power supply. Schritt 17 Unplug the small USB connector from its socket (labeled J4 in the service manual). ifixit CC BY-NC-SA de.ifixit.com Seite 11 von 17

Schritt 18 Disconnect the communications power cable from its socket (labeled J50 in the service manual). Only pull on the connector itself and not the socket. This connection is very tight, work the connector slowly and gently. Schritt 19 Unplug the large USB connector from its socket (labeled J8 in the service manual). ifixit CC BY-NC-SA de.ifixit.com Seite 12 von 17

Schritt 20 Press the tab on the ethernet cable and unplug it from its socket (labeled J9 in the service manual). Schritt 21 The following connector requires two hands to disconnect. Flip the rear case over, and lay it on its back to gain access to the power supply cable. ifixit CC BY-NC-SA de.ifixit.com Seite 13 von 17

Schritt 22 The power supply cable is secured by an interlocking connector that must be held open to unplug the connector. Insert the flat end of a spudger down into the power supply cover between the socket clip and the power supply connector. Schritt 23 Grasp the power supply cable firmly and lift both it and the spudger from the channel in the power supply housing to unplug the connector. ifixit CC BY-NC-SA de.ifixit.com Seite 14 von 17

Schritt 24 Power Supply Remove the four T10 Torx screws from the power supply cover. Schritt 25 Remove the power supply cover. ifixit CC BY-NC-SA de.ifixit.com Seite 15 von 17

Schritt 26 Unplug the AC power harness connectors from the IEC connector with a pair of pliers. During reassembly connect green to ground, blue to line (L), and brown to neutral (N). Schritt 27 Disconnect the ground connector from the ground plate. During reassembly plug the ground cable from the IEC connector onto the ground plate in the position closest to the IEC connector. Ensure that the green ground wires are routed over the blue and brown wires. ifixit CC BY-NC-SA de.ifixit.com Seite 16 von 17

Schritt 28 Use the flat end of a spudger to lift the power supply up off the posts in the rear housing. Lift and remove the power supply from the rear housing. Be very careful not to touch the capacitor leads or any exposed solder joints on the back of the power supply. Only handle the board by the edges. During reassembly ensure that the rubber grommet on the AC power harness is in the slot in the power-supply cover. Ensure that the green ground wires are secured under the power-supply cover. To reassemble your device, follow these instructions in reverse order. Dieses Dokument wurde zuletzt angelegt am 2018-03-14 04:29:41 PM. ifixit CC BY-NC-SA de.ifixit.com Seite 17 von 17