Cochlear implant patients localization using interaural level differences exceeds that of untrained normal hearing listeners

Similar documents
The use of interaural time and level difference cues by bilateral cochlear implant users

The development of a modified spectral ripple test

Binaural Hearing and Speech Laboratory. In un

Heath G. Jones, Alan Kan, and Ruth Y. Litovsky

Binaural Hearing. Why two ears? Definitions

Effect of mismatched place-of-stimulation on the salience of binaural cues in conditions that simulate bilateral cochlear-implant listening

Sound localization psychophysics

Effects of Interaural Pitch Matching and Auditory Image Centering on Binaural Sensitivity in Cochlear Implant Users

AUDL GS08/GAV1 Signals, systems, acoustics and the ear. Pitch & Binaural listening

Binaural advantages in users of bimodal and bilateral cochlear implant devices

Binaural Hearing. Steve Colburn Boston University

KEY WORDS: hearing preservation, localization, cochlear implants, hearing aids, acoustic hearing

Binaural hearing in children using Gaussian enveloped and transposed tones

Binaural unmasking with multiple adjacent masking electrodes in bilateral cochlear implant users

The REAL Story on Spectral Resolution How Does Spectral Resolution Impact Everyday Hearing?

Localization 103: Training BiCROS/CROS Wearers for Left-Right Localization

Cochlear Implantation Improves Localization Ability in Patients With Unilateral Deafness

3-D Sound and Spatial Audio. What do these terms mean?

Sensitivity to interaural envelope correlation changes in bilateral cochlear-implant users

The role of periodicity in the perception of masked speech with simulated and real cochlear implants

Rethinking Cochlear Implant Mapping for Bilateral Users. Learner Outcomes

Hearing the Universal Language: Music and Cochlear Implants

Cochlear Implants. What is a Cochlear Implant (CI)? Audiological Rehabilitation SPA 4321

Comparing Speech Perception Abilities of Children with Cochlear Implants and Digital Hearing Aids

DO NOT DUPLICATE. Copyrighted Material

21/01/2013. Binaural Phenomena. Aim. To understand binaural hearing Objectives. Understand the cues used to determine the location of a sound source

IN EAR TO OUT THERE: A MAGNITUDE BASED PARAMETERIZATION SCHEME FOR SOUND SOURCE EXTERNALIZATION. Griffin D. Romigh, Brian D. Simpson, Nandini Iyer

Discrimination and identification of azimuth using spectral shape a)

19 th INTERNATIONAL CONGRESS ON ACOUSTICS MADRID, 2-7 SEPTEMBER 2007 THE DUPLEX-THEORY OF LOCALIZATION INVESTIGATED UNDER NATURAL CONDITIONS

2/25/2013. Context Effect on Suprasegmental Cues. Supresegmental Cues. Pitch Contour Identification (PCI) Context Effect with Cochlear Implants

Sensitivity to Interaural Time Differences with Combined Cochlear Implant and Acoustic Stimulation

3-D SOUND IMAGE LOCALIZATION BY INTERAURAL DIFFERENCES AND THE MEDIAN PLANE HRTF. Masayuki Morimoto Motokuni Itoh Kazuhiro Iida

Effect of spectral content and learning on auditory distance perception

Interaural envelope correlation change discrimination in bilateral cochlear implantees: Effects of mismatch, centering, and onset of deafness

Neural correlates of the perception of sound source separation

Effect of age at onset of deafness on binaural sensitivity in electric hearing in humans

HHS Public Access Author manuscript Ear Hear. Author manuscript; available in PMC 2018 March 01.

INTRODUCTION J. Acoust. Soc. Am. 103 (2), February /98/103(2)/1080/5/$ Acoustical Society of America 1080

Trading Directional Accuracy for Realism in a Virtual Auditory Display

Speech conveys not only linguistic content but. Vocal Emotion Recognition by Normal-Hearing Listeners and Cochlear Implant Users

Psychophysics, Fitting, and Signal Processing for Combined Hearing Aid and Cochlear Implant Stimulation

Bilateral Cochlear Implant Guidelines Gavin Morrison St Thomas Hearing Implant Centre London, UK

Who are cochlear implants for?

Essential feature. Who are cochlear implants for? People with little or no hearing. substitute for faulty or missing inner hair

Binaural masking level differences in actual and simulated bilateral cochlear implant listeners

EFFECTS OF TEMPORAL FINE STRUCTURE ON THE LOCALIZATION OF BROADBAND SOUNDS: POTENTIAL IMPLICATIONS FOR THE DESIGN OF SPATIAL AUDIO DISPLAYS

Dynamic-range compression affects the lateral position of sounds

Study of perceptual balance for binaural dichotic presentation

Binaural detection with narrowband and wideband reproducible noise maskers. IV. Models using interaural time, level, and envelope differences

Bilateral Loudness Balancing and Distorted Spatial Perception in Recipients of Bilateral Cochlear Implants

Binaurally-coherent jitter improves neural and perceptual ITD sensitivity in normal and electric hearing

Brian D. Simpson Veridian, 5200 Springfield Pike, Suite 200, Dayton, Ohio 45431

arxiv: v1 [eess.as] 5 Oct 2017

Speech recognition by bilateral cochlear implant users in a cocktail-party setting

The role of low frequency components in median plane localization

Minimum Audible Angles Measured with Simulated Normally-Sized and Oversized Pinnas for Normal-Hearing and Hearing- Impaired Test Subjects

Production of Stop Consonants by Children with Cochlear Implants & Children with Normal Hearing. Danielle Revai University of Wisconsin - Madison

Spatial hearing benefits demonstrated with presentation of acoustic temporal fine structure cues in bilateral cochlear implant listeners a)

Modeling HRTF For Sound Localization in Normal Listeners and Bilateral Cochlear Implant Users

EXECUTIVE SUMMARY Academic in Confidence data removed

Comment by Delgutte and Anna. A. Dreyer (Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA)

1- Cochlear Impedance Telemetry

Essential feature. Who are cochlear implants for? People with little or no hearing. substitute for faulty or missing inner hair

Corporate Medical Policy

Effect of microphone position in hearing instruments on binaural masking level differences

Acoustic and Electric Same Ear Hearing in Patients with a Standard Electrode Array

Effects of Setting Thresholds for the MED- EL Cochlear Implant System in Children

Speaker s Notes: AB is dedicated to helping people with hearing loss hear their best. Partnering with Phonak has allowed AB to offer unique

JARO. Research Article. Abnormal Binaural Spectral Integration in Cochlear Implant Users

Variability in Word Recognition by Adults with Cochlear Implants: The Role of Language Knowledge

What Is the Difference between db HL and db SPL?

The Effect of Reducing the Number of Electrodes on Spatial Hearing Tasks for Bilateral Cochlear Implant Recipients DOI: /jaaa.21.2.

Effects of Presentation Level on Phoneme and Sentence Recognition in Quiet by Cochlear Implant Listeners

Spatial unmasking in aided hearing-impaired listeners and the need for training

Evidence based selection of hearing aids and features

What you re in for. Who are cochlear implants for? The bottom line. Speech processing schemes for

Hearing Research 299 (2013) 29e36. Contents lists available at SciVerse ScienceDirect. Hearing Research

PERIPHERAL AND CENTRAL AUDITORY ASSESSMENT

Localization in the Presence of a Distracter and Reverberation in the Frontal Horizontal Plane. I. Psychoacoustical Data

The Value of Two Ears for Sound Source Localization and Speech Understandi. Complex Listening Environments: Two Cochlear Implants vs.

Psychophysically based site selection coupled with dichotic stimulation improves speech recognition in noise with bilateral cochlear implants

Variation in spectral-shape discrimination weighting functions at different stimulus levels and signal strengths

Publication VI. c 2007 Audio Engineering Society. Reprinted with permission.

how we hear. Better understanding of hearing loss The diagram above illustrates the steps involved.

J. Acoust. Soc. Am. 114 (2), August /2003/114(2)/1009/14/$ Acoustical Society of America

LIMITATIONS ON MONAURAL AND BINAURAL TEMPORAL PROCESSING IN BILATERAL COCHLEAR IMPLANT LISTENERS

1706 J. Acoust. Soc. Am. 113 (3), March /2003/113(3)/1706/12/$ Acoustical Society of America

Effect of source spectrum on sound localization in an everyday reverberant room

Having Two Ears Facilitates the Perceptual Separation of Concurrent Talkers for Bilateral and Single-Sided Deaf Cochlear Implantees

Neural coding of ITD with bilateral cochlear implants: Effects of auditory experience

THE ROLE OF VISUAL SPEECH CUES IN THE AUDITORY PERCEPTION OF SYNTHETIC STIMULI BY CHILDREN USING A COCHLEAR IMPLANT AND CHILDREN WITH NORMAL HEARING

Lindsay De Souza M.Cl.Sc AUD Candidate University of Western Ontario: School of Communication Sciences and Disorders

Hearing II Perceptual Aspects

HearIntelligence by HANSATON. Intelligent hearing means natural hearing.

Juha Merimaa b) Institut für Kommunikationsakustik, Ruhr-Universität Bochum, Germany

Sound Localization in Bilateral Users of MED-EL COMBI 40/40 Cochlear Implants

Prelude Envelope and temporal fine. What's all the fuss? Modulating a wave. Decomposing waveforms. The psychophysics of cochlear

Effects of interaural time differences in fine structure and envelope on lateral discrimination in electric hearing a)

Physiological measures of the precedence effect and spatial release from masking in the cat inferior colliculus.

Transcription:

Cochlear implant patients localization using interaural level differences exceeds that of untrained normal hearing listeners Justin M. Aronoff a) Communication and Neuroscience Division, House Research Institute, 2100 West 3rd Street, Los Angeles, California 90057 jaronoff@hei.org Daniel J. Freed EarLens Corporation, 200 Chesapeake Drive, Redwood City, California 94063 dfreed@earlenscorp.com Laurel M. Fisher Clinical and Translation Science Division, House Research Institute, 2100 West 3rd Street, Los Angeles, California 90057 lfisher@hei.org Ivan Pal Compreval, Inc., 3 Spinnaker Court, Grayslake, Illinois 60030 ivan.compreval@gmail.com Sigfrid D. Soli Communication and Neuroscience Division, House Research Institute, 2100 West 3rd Street, Los Angeles, California 90057 ssoli@hei.org Abstract: Bilateral cochlear implant patients are unable to localize as well as normal hearing listeners. Although poor sensitivity to interaural time differences clearly contributes to this deficit, it is unclear whether deficits in terms of interaural level differences are also a contributing factor. In this study, localization was tested while manipulating interaural time and level cues using head-related transfer functions. The results indicate that bilateral cochlear implant users ability to localize based on interaural level differences is actually greater than that of untrained normal hearing listeners. VC 2012 Acoustical Society of America PACS numbers: 43.66.Pn, 43.66.Qp, 43.66.Ts [JL] Date Received: February 2, 2012 Date Accepted: March 12, 2012 1. Introduction Bilateral cochlear implant (CI) patients are unable to localize sounds as well as normal hearing (NH) listeners (Grantham et al., 2007; Majdak et al., 2011). NH listeners rely on interaural time differences (ITDs) and interaural level differences (ILDs) to localize sounds. However, bilateral CI users have considerable difficulty using ITDs to localize (Aronoff et al., 2010), indicating that their localization abilities are primarily or exclusively based on ILDs. Despite relying primarily on ILDs, studies that have measured ILD sensitivity (in terms of just-noticeable-differences) with acoustically presented stimuli have found that CI users ILD sensitivity is worse than that of NH listeners (Grantham et al., a) Also at: Neurobiology Department, University of Southern California, Los Angeles, CA 90089. Author to whom correspondence should be addressed. EL382 J. Acoust. Soc. Am. 131 (5), May 2012 VC 2012 Acoustical Society of America

2008; Laback et al., 2004). This suggests that CI users may also have a deficit in terms of ILD-based localization. Alternatively, CI users relative inability to localize using ITDs would result in extended localization experience relying primarily on ILDs. This in turn may have yielded better ILD-based localization abilities than is seen with untrained NH listeners. The goal of the current study was to compare NH and CI ILD-based localization abilities. 2. Methods 2.1 Participants Fifteen bilateral CI users were tested using their clinical settings. For the participants using a processor (Cochlear, Centennial, CO), noise canceling programs and auto-sensitivity, which are separately added in the clinical settings, were disabled. Table 1 provides details on the participants. Forty-two normal hearing listeners with pure tone thresholds 25 db hearing level (HL) from 0.25 to 8 khz also participated in this experiment. Localization performance for five of the bilateral CI users was reported in Aronoff et al. (2010). Table 1. Characteristics of the CI participants. ACE ¼ Advanced Combination Encoder; SPEAK ¼ Spectral Peak coding; CIS ¼ Continuous Interleaved Sampling; HDCIS ¼ High Definition Continuous Interleaved Sampling; FSP ¼ Fine Structure Processing. Processor Strategy Length of use (years) Etiology (patient report) Left Right Left Right Left Right Ototoxic Cochlear Cochlear ACE ACE 7 11 Ototoxic Cochlear Cochlear ACE ACE 0.5 0.5 Unknown Cochlear Cochlear ACE SPEAK 1 14 Progressive/ Cochlear Cochlear SPEAK ACE 16 0.5 hereditary Progressive Cochlear Cochlear ACE ACE 4 2 Hereditary/ Cochlear Cochlear ACE ACE 1 1 ototoxic Progressive AB Harmony a AB Harmony b HiRes/ HiRes/ 4 0.5 Fidelity 120 Fidelity 120 Progressive AB Harmony b AB Harmony b HiRes/ HiRes/ 2 5 Fidelity 120 Fidelity 120 Ototoxic AB Harmony b AB C1 b HiRes/ CIS 2 5 Fidelity 120 Unknown Med-El Tempoþ Med-El Tempoþ HDCIS HDCIS 7 7 Mumps/ Med-El Opus 2 Med-El Opus 2 HDCIS HDCIS 1 1 a measles Ménière s Med-El Opus 2 Med-El Opus 2 HDCIS HDCIS 2.5 Progressive Med-El Opus 2 Med-El Opus 2 HDCIS HDCIS 6 6 Ménière s Med-El Tempoþ Med-El Opus 2 CISþ FSP 7 1 Unknown Med-El Tempoþ Med-El Opus 2 CISþ FSP 7 3 a This participant originally was implanted on the right side three years before testing, but device channels started turning on and off unpredictably within three months, and the device was replaced approximately one year before testing. b Participants used the AB Tmic microphone for everyday listening. J. Acoust. Soc. Am. 131 (5), May 2012 Aronoff et al.: Cochlear implant users localization EL383

2.2 Stimuli Participants localization performance was tested using the source azimuth localization test (SALT; Aronoff et al., 2010; Chan et al., 2008), which consists of a broadband impulsive gunshot sound at one of twelve locations. The gunshot sound was chosen because it contains energy across a wide range of frequencies, providing both ITD and ILD cues. For the CI users, the stimuli were presented through the processor s auxiliary input using head-related transfer functions (HRTFs) specific to the type of processor they used in their everyday life. Processor-specific automatic gain control was applied to all signals, either by custom-built software (for Med-El s Tempoþ, Durham, NC) or by the processor itself. The stimuli were presented over headphones for the NH listeners. The HRTFs were previously validated by demonstrating comparable performance for sound field and HRTF-based SALT (Aronoff et al., 2010; Chan et al., 2008). The NH listeners were each tested with two sets of HRTFs such that there were data from 12 NH listeners for each processor-specific HRTF (see Table II in Aronoff et al., 2011 for a list of the sets of HRTFs tested with each participant). As a reference, data from 12 NH listeners were also collected using an acoustic hearing HRTF based on recordings from the microphone in the Zwislocki coupler of a Knowles Electronics Manikin for Acoustic Research (Itasca, IL). Versions of the HRTFs were created that preserved the ITDs, the ILDs, or both from the original HRTFs. For each HRTF, the ITD version preserved the phase response of the original HRTF, with the magnitude response for both ears replaced by the magnitude response derived from the right ear HRTF for a source at 180 (i.e., back center). The ILD version preserved the magnitude response of the original HRTF, with the phase response replaced for both ears by the phase response derived from the right ear HRTF for a source at 180. 2.3 Procedures Testing followed the same procedure as in Chan et al. (2008) and Aronoff et al. (2010). Participants were asked to locate a stimulus presented from one of 12 locations. Locations were chosen that were behind the head because it is more crucial in everyday life to be able to localize sounds behind the head based solely on auditory cues than it is to localize sounds in front of the listener, where there is often a visual cue that can be used to help localization. The locations were spaced 15 apart, ranging from 97.5 to 262.5. All locations were 1 m away from the listener. The locations were numbered from 1 12, with 1 located at 97.5 and 12 located at 262.5. The participant s task was to identify the location from which the stimulus originated by verbally indicating the number corresponding to the perceived location. Participants were provided with a diagram that divided the space behind the head into twelve numbered segments, with a stimulus location centered in each segment. Prior to testing in each condition, participants were familiarized with the stimulus locations by listening to the stimulus presented at each of the 12 locations, once in ascending and once in descending order. The location of each stimulus was indicated to the participant using the diagram described above. During familiarization, a reference stimulus was presented immediately prior to each target stimulus. This reference stimulus was located at 90 when familiarizing in the ascending order and at 270 when familiarizing in the descending order. After familiarization, participants were presented with a practice test that included each location presented in a random order. After completing the practice, the participants proceeded to the test. Neither the practice nor the test contained reference stimuli, and no feedback was provided. For the practice and test (but not for familiarization), roving was applied to prevent participants from localizing based on the overall loudness of the stimulus. The presentation level was roved by scaling the stimulus to the HRTF-specific root mean square (RMS) level for the right ear for a randomly selected location. This resulted in roving amounts ranging from 8.9 db [Advanced Bionics (AB) (Valencia, CA) Tmic HRTF] to 17.2 db ( HRTF, which uses a directional microphone), depending on the HRTF used. For the practice EL384 J. Acoust. Soc. Am. 131 (5), May 2012 Aronoff et al.: Cochlear implant users localization

and test, the target was presented twice at a given location prior to the participant indicating the perceived location of the stimulus. The number of stimuli presented during the test was determined by the participant s localization performance, calculated based on the first block of 24 stimuli (Chan et al., 2008). Participants who, at minimum, were able to distinguish adjacent groups of three locations with an accuracy of at least 75% in the first block were presented with a second block of 24 stimuli. If the required level of accuracy was not achieved in the first block, no additional blocks were tested and the participant s score was calculated based on their performance on the first block. Otherwise, the participant s score was calculated based on their performance combined across the first and second block. The final test score was determined by calculating the RMS localization error, in degrees, based on all responses. 3. Results Robust statistical techniques and measures were adopted to minimize the potential effect of any outliers or non-normality in the data (for more detail, see the Appendix in Aronoff et al., 2011). RMS error for the CI listeners was analyzed using a percentile bootstrap analysis based on 20% trimmed means. Because different CI listeners used different microphones corresponding to different HRTFs, CI performance was compared to an NH weighted 20% trimmed mean, calculated by weighting the NH 20% trimmed mean for each HRTF (presented in Table 2) by the number of CI users in this study using that particular HRTF. Consistent with previous research (Grantham et al., 2007; Majdak et al., 2011), this analysis indicated that the CI users binaural localization was significantly poorer than that of the typical NH listener (p < 0.0001; CI 20% trimmed mean: 27 ; NH weighted trimmed mean: 20 ; all scores indicate RMS error and lower scores indicate better performance; see Fig. 1). Although poor ITD-based localization likely contributed to the CI users binaural deficit, it is not clear if reduced ILD-based localization also played a role. To determine whether the CI users had poor ITD- and ILD-based localization compared to NH listeners, localization performance with the ITD and ILD HRTFs was analyzed using a percentile bootstrap analysis based on 20% trimmed means. As expected, CI users ITD-based localization was significantly poorer than that of the typical NH listener (p < 0.0001; CI 20% trimmed mean: 62 ; NH weighted trimmed mean: 24 ; see Fig. 1). In contrast, the analysis of ILD-based localization indicated that CI users were significantly better than the typical NH listener (p < 0.01; CI 20% trimmed mean: 28 ; NH weighted trimmed mean: 37 ; see Fig. 1). This was the case even if CI performance was compared to that of NH listeners using the acoustic hearing HRTF (p < 0.02; NH 20% trimmed mean: 34 ). These results suggest that bilateral CI users have exceptional localization abilities using ILDs. 4. Discussion The CI users ILD-based localization performance was particularly striking, reflecting performance above that of the NH listeners. This may reflect how the signal is Table 2. Trimmed means of RMS error in degrees for the NH listeners for each HRTF. The standard deviation, calculated using Sn (see the Appendix in Aronoff et al., 2011) is shown in parentheses. HRTF ITD þ ILD ITD ILD Acoustic hearing 24.0 (8.4) 25.8 (10.7) 34.4 (8.3) AB (Tmic) 17.1 (4.8) 22.1 (4.8) 39.6 (7.2) 20.8 (9.5) 24.3 (9.5) 34.0 (9.5) Tempoþ 18.0 (6.0) 21.9 (4.8) 32.3 (10.7) Opus 2 20.9 (6.0) 23.3 (4.8) 38.3 (9.5) Tempoþ/Opus 2 22.1 (6.0) 25.1 (3.6) 43.5 (8.4) J. Acoust. Soc. Am. 131 (5), May 2012 Aronoff et al.: Cochlear implant users localization EL385

Fig. 1. In the top left panel, localization scores in terms of RMS error are provided for CI listeners and NH listeners. Each data point represents the trimmed mean for the CI users and the weighted trimmed mean for the NH listeners. Error bars indicate 95% confidence intervals for the trimmed means based on bootstrap analyses. Lower scores indicate better performance. Response patterns are shown in the top right panel. In the bottom panel, performance for each CI user is presented. Participants are ordered based on performance using the ITD þ ILD HRTFs. To facilitate comparison across different processors, scores are presented as percentiles based on a normal distribution with a mean and standard deviation matching the processor-specific NH data presented in Table 2. Lower scores indicate better performance. Results suggest that CI users binaural localization deficit largely reflects a deficit for using ITD cues, alongside exceptional performance using ILD cues. processed by the cochlear implant, possibly resulting in magnified ILD cues. However, the results from Grantham et al. (2008) and Laback et al. (2004), indicating that CI users have worse ILD sensitivity when using speech processors compared to NH listeners, would suggest that this is not the case. Alternatively, CI users excellent ILD-based localization may reflect differences in the perceptually available information since the HRTFs with only ILDs preserved may sound similar to the ITD þ ILD HRTFs for CI users, given their minimal access to ITDs when using clinical processors. However, one CI user was able to localize relatively well with ITD cues [the bilateral Tempoþ (Med-El, Durham, NC) user had an ITD-based localization RMS error score of 33 ], yet her ILD-based localization (RMS error score of 24 ) was still better than that of the typical NH listener using any of the HRTFs. Another explanation may be that CI users have learned to better use ILD cues as a result of their minimal access to ITD cues, much as patients with high frequency hearing loss make better use of low frequency information (Hornsby et al., 2011). This would suggest that, with proper training, NH listener s ILD-based localization may be comparable to or exceed that of the CI users. Despite excellent localization using ILDs, the results also indicated that the CI users ILD-based localization did not compensate for their inability to use ITD cues. Consistent with previous studies (e.g., Grantham et al., 2007; Majdak et al., 2011), when both ITD and ILD cues were combined, CI users did not perform as well as the typical NH listener. This suggests that CI users difficulty using ITD cues with clinical processors is significantly limiting their ability to localize sounds. As such, improving CI users localization may require improving ITD sensitivity. There are a number of ways that may be accomplished, such as by using low pulse rates (van Hoesel et al., 2009), or reducing interaural mismatches in terms of place of stimulation (Poon et al., 2009). Conversely, given CI users impressive ILD-based localization, it may be possible to improve localization by enhancing ILDs. EL386 J. Acoust. Soc. Am. 131 (5), May 2012 Aronoff et al.: Cochlear implant users localization

5. Conclusions Previous studies have indicated that bilateral CI users ILD sensitivity is worse than that of NH listeners. However, that deficit does not translate into a comparable deficit in ILD-based localization. Instead, the results of this study indicate that CI users ability to localize using ILD cues is better than that of untrained NH listeners. Acknowledgments We thank our participants for their time and effort. We also thank Advanced Bionics, Cochlear Ltd., and Med-El for providing equipment and expertise for this study, and John Wygonski for hardware development. This work was supported by NIH Grant Nos. R44DC005759 (S.D.S.) and T32DC009975 (J.M.A.). References and links Aronoff, J. M., Freed, D. J., Fisher, L., Pal, I., and Soli, S. D. (2011). The effect of different cochlear implant microphones on acoustic hearing individuals binaural benefits for speech perception in noise, Ear Hear. 32(4), 468 484. Aronoff, J. M., Yoon, Y.-S., Freed, D. J., Vermiglio, A. J., Pal, I., and Soli, S. D. (2010). The use of interaural time and level difference cues by bilateral cochlear implant users, J. Acoust. Soc. Am. 127(3), EL87 EL92. Chan, J. C., Freed, D. J., Vermiglio, A. J., and Soli, S. D. (2008). Evaluation of binaural functions in bilateral cochlear implant users, Int. J. Audiol. 47(6), 296 310. Grantham, D. W., Ashmead, D. H., Ricketts, T. A., Labadie, R. F., and Haynes, D. S. (2007). Horizontal-plane localization of noise and speech signals by postlingually deafened adults fitted with bilateral cochlear implants, Ear. Hear. 28(4), 524 541. Grantham, D. W., Ashmead, D. H., Ricketts, T. A., Haynes, D. S., and Labadie, R. F. (2008). Interaural time and level difference thresholds for acoustically presented signals in post-lingually deafened adults fitted with bilateral cochlear implants using CISþ processing, Ear. Hear. 29(1), 33 44. Hornsby, B. W. Y., Johnson, E. E., and Picou, E. (2011). Effects of degree and configuration of hearing loss on the contribution of high- and low-frequency speech information to bilateral speech understanding, Ear. Hear. 32(5), 543 555. Laback, B., Pok, S.-M., Baumgartner, W.-D., Deutsch, W. A., and Schmid, K. (2004). Sensitivity to interaural level and envelope time differences of two bilateral cochlear implant listeners using clinical sound processors, Ear. Hear. 25(5), 488 500. Majdak, P., Goupell, M. J., and Laback, B. (2011). Two-dimensional localization of virtual sound sources in cochlear-implant listeners, Ear. Hear. 32(2), 198 208. Poon, B. B., Eddington, D. K., Noel, V., and Colburn, H. S. (2009). Sensitivity to interaural time difference with bilateral cochlear implants: Development over time and effect of interaural electrode spacing, J. Acoust. Soc. Am. 126(2), 806 815. van Hoesel, R. J., Jones, G. L., and Litovsky, R. Y. (2009). Interaural time-delay sensitivity in bilateral cochlear implant users: Effects of pulse rate, modulation rate, and place of stimulation, J. Assoc. Res. Otolaryngol. 10(4), 557 567. J. Acoust. Soc. Am. 131 (5), May 2012 Aronoff et al.: Cochlear implant users localization EL387