Evaluation of Volume and Total Nucleated Cell Count as Cord Blood Selection Parameters A Receiver Operating Characteristic Curve Modeling Approach

Similar documents
Placental and Umbilical Cord Blood as a Source of Stem Cells

Aldehyde Dehydrogenase Activity as a Marker of Quality in Cryopreserved Cord Blood

Study for the improvement of umbilical cord blood sampling using a new trial apparatus

BMTCN REVIEW COURSE PRE-TRANSPLANT CARE

Cord Blood Stem Cell Banking and Transplantation

Correlation of umbilical cord blood volume with CD34+ cells concentration

Medical Policy. MP Placental and Umbilical Cord Blood as a Source of Stem Cells

The number of nucleated cells reflects the hematopoietic content of umbilical cord blood for transplantation

One-Unit versus Two-Unit Cord-Blood Transplantation for Hematologic Cancers

Analysis of the Viability of Umbilical Cord blood Stem Cells. Sachdeva N

CHAPTER 3 LABORATORY PROCEDURES

Haplo vs Cord vs URD Debate

Cord Blood Bankers are. Angie Yost, MT(ASCP) CM 2016 ASCLS-MO CLMA Spring Meeting

Applications of Cord Blood Stem Cells

Umbilical Cord Blood Transplantation

A Review of Procedures Involved in Human Umbilical Cord Blood Banking and Transplantation

Clinical Use of Umbilical Cord Blood Hematopoietic Stem Cells

HSCT MANAGEMENT WHITE PAPER. Managing stem cell apheresis effectively

Research Article Mean Platelet Volume Reflect Hematopoietic Potency and Correlated Blood Group O in Cord Blood from Healthy Newborn

What the Transfusion Scientist should know about Stem Cells. Dr Claire Wiggins BBTS September 2017

OneMatch Stem Cell and Marrow Network. Training Guide

REVIEW ARTICLE. Umbilical Cord Blood Transplantation: Where Do We Stand? ASBMT BB&MT. Raymond C. Wadlow, David L. Porter

Hematopoiesis i starts from. HPC differentiates t to sequentially more mature. HPC circulate in very low

Analysis of Hematopoietic Cell Transplants Using Plasma-Depleted Cord Blood Products That Are Not Red Blood Cell Reduced

Peripheral blood stem cells Number of viable CD34 + cells reinfused predicts engraftment in autologous hematopoietic stem cell transplantation

NIH Public Access Author Manuscript Lancet Oncol. Author manuscript; available in PMC 2011 August 29.

SECOND ANNUAL INTERNATIONAL UMBILICAL CORD BLOOD SYMPOSIUM

Graft source and Stem cell collection SULADA PUKIAT, MD

Cord Blood Banking. The Birth of a New Field

The National Marrow Donor Program. Graft Sources for Hematopoietic Cell Transplantation. Simon Bostic, URD Transplant Recipient

Madrid Cord Blood Bank, b Department of Hematology, c Department of Immunology, Hospital Universitario 12 de Octubre, Madrid, Spain

Protocol Number: 10-CBA National Clinical Trial (NCT) Identified Number: NCT

Dr.PSRK.Sastry MD, ECMO

Original article. Department of Pediatrics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, 2

A Meta-Analysis of Unrelated Donor Umbilical Cord Blood Transplantation versus Unrelated Donor Bone Marrow Transplantation in Acute Leukemia Patients

& 2007 Nature Publishing Group All rights reserved /07 $

Quality rather than quantity: the cord blood bank dilemma

Teja Falk Radke, 1 David Barbosa, 1 Richard Charles Duggleby, 2,3 Riccardo Saccardi, 4,5 Sergio Querol, 2,6 and Gesine Kögler 1. 1.

Umbilical cord blood transplantation for acute myeloid leukemia Anjali S. Advani a and Mary J. Laughlin b

Haploidentical Transplantation: The Answer to our Donor Problems? Mary M. Horowitz, MD, MS CIBMTR, Medical College of Wisconsin January 2017

EBMT Complications and Quality of Life Working Party Educational Course

Status of umbilical cord blood transplantation in the year 2001

The Texas Medical Center

journal of medicine The new england Outcomes after Transplantation of Cord Blood or Bone Marrow from Unrelated Donors in Adults with Leukemia abstract

Customer Information Literature List Platelets

Both AABB and the Foundation for the Accreditation

Telephone: ; Fax: ; E mail:

Paola Di Ciaccio Vanja Nikolac

The role of HLA in Allogeneic Hematopoietic Stem Cell Transplantation and Platelet Refractoriness.

Federica Galaverna, 1 Daria Pagliara, 1 Deepa Manwani, 2 Rajni Agarwal-Hashmi, 3 Melissa Aldinger, 4 Franco Locatelli 1

Applications for the MACSQuant Analyzer *

UMBILICAL CORD BLOOD STEM CELLS EXPANDED IN THE PRESENCE OF NICOTINAMIDE (NICORD) PROVIDE LONG TERM MULITI-LINEAGE ENGRAFTMENT

HHS Public Access Author manuscript Bone Marrow Transplant. Author manuscript; available in PMC 2015 July 01.

Objectives. Cord Blood is RelaOvely Recent Technology BMT Pharmacists Conference: Debate - Haploidentical vs. Umbilical Cord Blood Transplant

Blood and Marrow Transplant (BMT) for Sickle Cell Disease

HEMATOPOIETIC ENGRAFTMENT IN ADULT RECIPIENTS OF UMBILICAL-CORD BLOOD FROM UNRELATED DONORS

Hematopoietic Engraftment in Recipients of Unrelated Donor Umbilical Cord Blood Is Affected by the CD34 and CD8 Cell Doses

Potency & Release Testing for unrelated donor cord blood units

About OMICS Group Conferences

KEY WORDS: Hematopoietic stem cell mobilization, Granulocyte colony-stimulating factor, Healthy donor, Apheresis

Stem Cell Transplantation for Severe Aplastic Anemia

Evaluation of Early Post-transplant Leukocyte Recovery Using the Undiluted Erythrocyte Lysing Technique

What s a Transplant? What s not?

Carlos Bachier, Josh Potter, Grant Potter, Rominna Sugay, Paul Shaughnessy, Kawah Chan, Veronica Jude, Renee Madden, Charles F.

Cord Blood Transplant. E. Gluckman Eurocord ESH-EBMT training course Vienna 2014

Clinical Policy: Donor Lymphocyte Infusion

Use of alternative donors in HSCT (Europe)

Unrelated Donor StemCell Transplantation: The Role of the National Marrow Donor Program

THIRD ANNUAL INTERNATIONAL UMBILICAL CORD BLOOD TRANSPLANTATION SYMPOSIUM

CELLULAR THERAPY QUIZ. Correct answers and rationale

D7.1 Report summarising results of survey of EU countries to identify volumes and trends in relation to the import and export of stem cells

D7.1 Report summarising results of survey of EU countries to identify volumes and trends in relation to the import and export of stem cells

XM-ONE XM-ONE XM-ONE. References XMO_V4.0_100205_CE.EU

Stem cell transplantation for haemoglobinopathies. Dr P J Darbyshire Birmingham Childrens Hospital

Cord blood transplantation and stem cell regenerative potential

Autologous peripheral blood stem cells (PBSC)

Transplantation - Challenges for the future. Dr Gordon Cook S t James s Institute of Oncology, Leeds Teaching Hospitals Trust

National Marrow Donor Program HLA-Matching Guidelines for Unrelated Marrow Transplants

Biol Blood Marrow Transplant 19 (2013) 156e160

Department of Pharmacy, Georgia Health Sciences University, Augusta, GA, USA 3

GVHD. URD unrelated donor

Autologous hematopoietic stem cell (HSC)

CryoStor CS2, CS5 and CS10 FREEZE MEDIA

Getting Beyond the Flags: Quantitative assessment of immature granulocyte (IG) populations may improve the assessment of sepsis and inflammation.

Sickle Cell Diseasechronic. curable disease? Objectives. Why would a family ask about cure for SCD?

HLA Match Likelihoods for Hematopoietic Stem-Cell Grafts in the U.S. Registry

It has been widely accepted that cryopreservation

Human Umbilical Cord Blood CD34 + /133+ Progenitor Cell Care Manual

J.A. García Vela a,, I. Delgado a, R. Bornstein b, B. Alvarez a, M.C.Auray b, I. Martin a, F.Oña a and F. Gilsanz b

ISCT Workshop #7 Perspectives in Cell Selection Immunomagnetic Selection

The Journal of International Medical Research 2011; 39:

Hematopoietic Stem Cell Transplant in Sickle Cell Disease- An update

Review Article. Umbilical cord blood transplantation: the first 25 years and beyond. Introduction. Scientific basis of cord blood transplantation

XIV. HLA AND TRANSPLANTATION MEDICINE

Introduction 6/7/2013. Umbilical Cord Blood Transplantation: Research and Clinical Applications

Sterility Testing of Peripheral Blood Stem cell (PBSC) harvests in a Tertiary Oncology Setup

IN UTERO HEMATOPOIETIC STEM CELL TRANSPLANTATION IN CANINES: THE GESTATIONAL WINDOW OF OPPORTUNITY TO MAXIMIZE ENGRAFTMENT

Cord-Blood Transplantation in Patients with Minimal Residual Disease

More than 30 years ago it was demonstrated

Factors Influencing Haematopoietic Progenitor cell transplant outcome Optimising donor selection

Transcription:

Hematopathology / Umbilical Cord Blood Selection Evaluation of Volume and Total Nucleated Cell Count as Cord Blood Selection Parameters A Receiver Operating Characteristic Curve Modeling Approach José C. Jaime-Pérez, MD, PhD, Roberto Monreal-Robles, MD, Laura N. Rodríguez-Romo, MD, Consuelo Mancías-Guerra, MD, José Luís Herrera-Garza, MD, and David Gómez-Almaguer, MD Key Words: Umbilical cord blood banking; Cord blood selection; CD34+ cord blood cells; Cord blood total nucleated cell content; Cord blood volume; Receiver operating characteristic analysis; Sensitivity; Specificity DOI: 10.1309/AJCPFB6EXO7BJVLR Abstract The objective of the study was to evaluate the current standard practice of using volume and total nucleated cell (TNC) count for the selection of cord blood (CB) units for cryopreservation and further transplantation. Data on 794 CB units whose CD34+ cell content was determined by flow cytometry were analyzed by using a receiver operating characteristic (ROC) curve model to validate the performance of volume and TNC count for the selection of CB units with grafting purposes. The TNC count was the best parameter to identify CB units having 2 10 6 or more CD34+ cells, with an area under the ROC curve of 0.828 (95% confidence interval, 0.800-0.856; P <.01) and an efficiency of 75.4%. Combination of parameters (TNC/mononuclear cells [MNCs], efficiency 74.7%; TNC/volume, efficiency 68.9%; and volume/mncs, efficiency 68.3%) did not lead to improvement in CB selection. All CB units having a TNC count of 8 10 8 or more had the required CD34+ cell dose for patients weighing 10 kg or less. Umbilical cord blood (UCB) is used as an alternative source of progenitors for hematopoietic stem cell (HSC) transplantation. Worldwide, more than 450,000 UCB units have been stored in CB banks (CBBs), and more than 10,000 UCB transplants have been performed in children and adults for a variety of disorders, 1 including hematologic malignancies, bone marrow failure syndromes, selected hereditary immunodeficiency states, and metabolic disorders. 2-5 The current status and future trends in this complex and rapidly evolving field have been recently reviewed. 6 HSCs are contained within a population of mononuclear CD34+ antigen-expressing cells, which typically represent fewer than 1% of the total leukocytes in CB. 7 The CD34+ antigen is the accepted marker for determining the HSC content in bone marrow, peripheral blood, and UCB. 8 Although no universally accepted guidelines exist, most CBBs use the combination of product weight (volume) and total nucleated cell (TNC) count as the main selection factors for cryopreservation, requiring a TNC content from 6 to 10 10 8 for storage 9 and a minimal volume between 40 and 60 ml. 10-12 The CD34+ cell content has been shown to influence engraftment and survival after unrelated UCB transplantation, better predicting the hematopoietic potential of a CB unit than nucleated cell content. 13 For partially mismatched HLA transplants, the number of CD34+ cells infused is critical, with 1.7 10 5 CD34+ cells per kilogram of the recipient s body weight the threshold dose. 13 Taking into account a 10% to 20% cell loss during freezing-thawing procedures, a dose of 2.0 10 5 CD34+ cells per kilogram of recipient s weight before cryopreservation seems to be more suitable for the selection of CB units for storage. To know the CD34+ cell number in a CB unit could Am J Clin Pathol 2011;136:721-726 721 721 DOI: 10.1309/AJCPFB6EXO7BJVLR 721

Jaime-Pérez et al / Umbilical Cord Blood Selection be relevant in several aspects, including matching the weight of the intended recipient with the appropriate unit; also, it would allow more precise selection of CB units to perform double-unit transplants for adolescents and adults, as reported. 14 However, owing to the lack of standardization of CD34+ cell counting methods, it is currently not possible to compare CD34+ cell counts among CBBs or transplant centers. Receiver operating characteristic (ROC) curve analysis is a graphic representation of the reciprocal relationship between sensitivity and specificity and provides an objective measure of the overall diagnostic performance of a test; it has been frequently used to compare diagnostic tests. 15,16 We were able to locate only 2 published reports on CB selection using ROC analysis; one focused on obstetric factors to establish selection criteria for CB cryopreservation, 17 and the other dealt with fetal biometry in which prebirth assessment of biparietal diameter might allow the selection of donors who would yield CB units of sufficient volume and cell content. 18 We decided to use formal statistical analysis and ROC curve modeling to analyze the standard practice at most CBBs for using volume and/or the TNC count for the proper selection of suitable CB units for further transplantation. Materials and Methods The characteristics of 794 CB units received between May 2005 and May 2010 at the CBB of the Hematology Department, Dr José E. Gonzalez University Hospital, School of Medicine of the Universidad Autónoma de Nuevo León, Monterrey, México, were retrospectively analyzed for this study. UCB Collection Informed consent for UCB collection was obtained from healthy women with uncomplicated pregnancies receiving care at the Obstetrics Department, University Hospital Dr. José Eleuterio González and other regional hospitals. UCB was collected by gravity into a 150-mL sterile bag collection set (Grifols, Barcelona, Spain), containing 25 ml of citratephosphate-dextrose anticoagulant. The CB unit was then stored on wet ice for transport to the CBB for processing. As do others, 10,11,19 at our CBB, we use volume and the TNC count as criteria for the selection of CB units for cryopreservation. UCB units were analyzed for nucleated cell counts and were cryopreserved if their TNC number was at least 8 10 8 and their volume exceeded 80 ml, including the anticoagulant. The time from collection to processing was set at 48 hours or less. Laboratory Processing After removal of aliquots for routine testing, UCB in the collection bag was mixed with 6% hydroxyethyl starch (HES) in a 1:4 ratio, with 30 ml as the maximum. The buffy coat was then separated by centrifuging at 45g for 7 minutes at 10 C according to a method previously described. 20 The UCB/HES mixture and the supernatant plasma were transferred into a second plasma transfer bag without severing the connecting tube. A second centrifugation step was performed at 600g for 15 minutes at 10ºC. The cell suspension was removed into a processing set (Pall Medical, Covina, CA) and adjusted to precisely 20 ml. The equipment used to perform the volume reduction was an automated closed system, Sepax- 100 (Biosafe America, Houston, TX). The cryocyte bag was placed in the Coolmix-210 (Biosafe America), which kept it in constant agitation for adding the cryoprotective mixture, which consists of 2.5 ml of DMSO (dimethyl sulfoxide) 99.9% (Sigma-Aldrich, St Louis, MO) and 2.5 ml of Dextran 40 (Sigma-Aldrich). When the temperature reached 4ºC, the cryocyte bag was placed in a protective aluminum cassette (Medical Technology Vertriebs, Altdorf, Germany) and then deposited horizontally on a level surface inside a controlledrate freezer (Cryomed, Thermo Forma, Marietta, OH) until it reached 90 C. The units were then transferred into the liquid phase of a nitrogen freezer (Cryoplus, Thermo Forma) for long-term storage. Biologic Studies TNC Counting TNC counts were determined with an automated hematology analyzer (Sysmex XT 2000, Sysmex, Mundelein, IL) using a multiangle polarized scatter separation technique, which provides the primary TNC count. The TNC was calculated by multiplying the TNC for the total volume of the bag. The total mononuclear cell (MNC) counts were calculated by adding the absolute count of lymphocytes and monocytes reported in the CBC count and then multiplying this value for the total volume of the bag. CD34+ Cell Counting Before cryopreservation, CD34+ cell counts were determined with the ISHAGE gating strategy 21 using monoclonal antibodies anti-cd45+ fluorescein isothiocyanate (FITC; Becton Dickinson, San Jose, CA) and monoclonal antihuman CD34 class III/FITC, clone BIRMA K-3 (DAKO, Glostrup, Denmark). CD34+ cells were enumerated using a FACSCalibur flow cytometer (Becton Dickinson). Statistical Analysis Normality of the studied variables was assessed with the Kolmogorov-Smirnov test. Spearman correlation set at a significance level of.01 was performed to assess the correlation of volume and TNC and MNC counts with the CD34+ 722 Am J Clin Pathol 2011;136:721-726 722 DOI: 10.1309/AJCPFB6EXO7BJVLR

Hematopathology / Original Article cell content of the CB units. ROC curve analysis was applied to evaluate the performance of volume, TNC count, and absolute MNC counts as a method for identifying CB units with a CD34+ cell content of 2 10 6 or more, determining also the optimal operating point allowing the best performance for the CB parameter selected. We arbitrarily added different cutoff points for comparing the performance of the selected parameter at different values, determining their sensitivity, specificity, positive and negative predictive values, efficiency, and positive and negative likelihood ratios. 22-25 The analyzed units were divided in 2 groups depending on a CD34+ cell count, 2 10 6 or more or fewer than 2 10 6 as determined by flow cytometry. Descriptive statistics (percentages, mean, SD, median, and range) were used to analyze the UCB units group with a count of 2 10 6 or more CD34+ cells, presenting the number and total CD34+ cell content of CB units that would be suitable for transplantation based on the required dose of 2 10 5 CD34+ cells/kg, estimated for recipients weighing 10 to 40 kg. The statistical package used was SPSS, version 17.0 (SPSS, Chicago, IL). MedCalc statistical software (MedCalc, Mariakerke, Belgium) was used for ROC curve analysis. Results We studied 794 CB units received at our CBB during a 5-year period. By applying the current criteria, we found that our banking efficiency was 57.5%. The initial analysis revealed a direct correlation in volume, absolute TNC and MNC counts, and the total number of CD34+ cells. The TNC content had the most significant correlation with the number of CD34+ cells (r = 0.681; P <.01), compared with the MNC count (r = 0.655; P <.01) and volume (r = 0.581; P <.01). ROC analysis showed the TNC count to be the parameter with a superior area under the ROC curve, 0.828 (95% confidence interval [CI], 0.800-0.856), with a significant difference compared with the MNC count (0.810; 95% CI, 0.780-0.840; 0.0 0.0 0.2 0.4 Table 1 Performance Evaluation for Different ROC-Derived TNC Cutoff Values for Cord Blood Selection Sensitivity 1.0 0.8 0.6 0.4 0.2 1 Specificity TNC count MNC count Volume Reference line 0.6 0.8 1.0 Figure 1 Receiver operating characteristic (ROC) curve analysis comparing the performance of volume (area under the ROC curve [AUC] = 0.784), total nucleated cell (TNC) count (AUC = 0.828), and absolute mononuclear cell (MNC) count (AUC = 0.810) as criteria for selecting cord blood units suitable for cryopreservation. P <.05) and volume (0.784; 95% CI, 0.753-0.816; P <.001) Figure 1. There was no significant difference in the area under the ROC curve between volume and MNC count (P =.56). A TNC count of 8.32 10 8 was the optimal operating point chosen by ROC analysis that most accurately allowed for the selection of CB units meeting the CD34+ cell content of 2 10 6 (sensitivity, 78.7%; specificity, 70.7%) Table 1 and Figure 2. We also evaluated the performance of combining parameters (TNC/MNC, efficiency 74.7%; TNC/volume, efficiency 68.9%; and volume/mnc, efficiency 68.3%) in the function of their best cutoff values derived from the ROC curve without documenting improved performance on CB selection. TNC Cutoff Value ( 10 8 ) Performance Measure 8.0 8.32 * 9.0 10.0 11.0 12.0 13.0 Sensitivity (%) 80.9 78.7 69.7 59.6 49.5 40.3 33.2 Specificity (%) 65.6 70.7 76.8 84.1 90.8 93.9 96.6 Negative predictive value (%) 70.7 70.1 64.1 59.4 55.9 52.5 50.4 Positive predictive value (%) 76.9 79.2 81.0 84.0 88.5 90.3 93.3 Efficiency (%) 74.5 75.4 72.6 69.7 66.6 62.4 59.4 Positive likelihood ratio 2.4 2.7 3.0 3.7 5.4 6.6 9.8 Negative likelihood ratio 0.3 0.3 0.4 0.5 0.6 0.6 0.7 ROC, receiver operating characteristic; TNC, total nucleated cell. * Optimal operating point chosen by ROC analysis. Am J Clin Pathol 2011;136:721-726 723 723 DOI: 10.1309/AJCPFB6EXO7BJVLR 723

Jaime-Pérez et al / Umbilical Cord Blood Selection Sensitivity 1.0 0.8 0.6 0.4 It is interesting that when applying the ROC-selected TNC cutoff as selection criterion to the 466 CB units having a CD34+ cell content of 2 10 6 or more, the CD34+ cell median content increased by 11%, from 3.4 10 6 to 3.8 10 6, although at the expense of a 21% (n = 99) decrease in the number of CB units available for transplantation. This approach would lead to an increase in the percentage of units stored that could be safely grafted, particularly for patients weighing 15 to 25 kg Table 2 and Figure 3. 0.2 0.0 0.0 0.2 0.4 1 Specificity 0.6 0.8 1.0 Figure 2 Receiver operating characteristic (ROC) curve analysis of absolute total nucleated cell count with an area under the ROC curve of 0.828 (95% confidence interval, 0.800-0.856; P <.01). The optimal ROC-derived cutoff (square) shown has a sensitivity of 78.7% and a specificity of 70.7%. The characteristics of the CB units meeting a CD34+ cell content of 2 10 6 or more (n = 466 [58.7%]) were further analyzed. The median volume obtained was 106.3 ml (range, 48.0-213.2 ml) with a median TNC content of 11.0 10 8 (range, 2.5 10 8-36.6 10 8 ) and a median CD34+ cell count of 3.4 10 6 (range, 2.0 10 6-19.4 10 6 ) after volume reduction and before cryopreservation. Based on the requirement of 2 10 5 CD34+ cells per kilogram of recipient weight before freezing the CB, this approach would make it possible to use 100%, 37.3%, 15.2%, and 7.5% of CB units for patients weighing 10, 20, 30, or 40 kg, respectively (data not shown). Discussion Although different studies have been performed regarding selection, collection, and processing of CB, 17,26-30 improvement in methods is needed to maximize resource utilization without compromising quality for clinical use, to increase efficacy, and to reduce the cost of CB grafting. The TNC count had the largest area under the ROC curve, confirming that it is the primary driver of the CD34+ cell content in CB. Combining 2 parameters to select CB did not lead to an improvement in the relationship between sensitivity and specificity; therefore, the TNC count as a single criterion seems to be sufficient for selecting CB units for cryopreservation. Most of the CB units not meeting the CD34+ cell content of 2 10 6 or more had a TNC count below the ROC-selected value. These units would not have been processed for CD34+ cell content had this cutoff point been applied. It is worth mentioning that of all CB units with a TNC count more than the ROC-selected value, only 20% had a CD34+ cell count of less than 2 10 6. These units, however, could potentially be used for double partially HLA-matched UCB transplantation in adults who otherwise are not eligible for allogeneic grafting owing to the lack of a suitable single- UCB unit, as previously reported. 14 Table 2 Descriptive Statistics for Cord Blood Units With a CD34+ Cell Count of 2 10 6 or More According to TNC Cutoff Selection Criterion and the Requirement of 2 10 5 CD34+ Cells per Kilogram of Patient Weight, Estimated for 10 to 40 kg (n = 466) * CD34+ MNC ( 10 6 ) Patient Weight (kg) TNC Cutoff ( 10 8 ) Mean ± SD Median 10 20 30 40 8.0 4.4 ± 2.5 3.7 377 164 (43.5) 70 (18.6) 35 (9.3) 8.32 4.5 ± 2.6 3.8 367 163 (44.4) 70 (19.1) 35 (9.5) 9.0 4.6 ± 2.6 3.9 325 156 (48.0) 67 (20.6) 35 (10.8) 10.0 4.9 ± 2.7 4.2 278 148 (53.2) 67 (24.1) 35 (12.5) 11.0 5.2 ± 2.9 4.6 231 136 (58.9) 64 (27.7) 35 (15.2) 12.0 5.3 ± 3.0 4.6 188 114 (60.6) 54 (28.7) 29 (15.4) 13.0 5.7 ± 3.0 4.9 155 106 (68.4) 51 (32.9) 27 (17.4) MNC, mononuclear cells; TNC, total nucleated cell. * All units met the required dose for patients weighing 10 kg; 89 units containing 2 10 6 CD34+ did not meet the 8 10 8 TNC content. For 20-40 kg, data are given as number (percentage) in relation to the value in the 10-kg column. Optimal operating point chosen by receiver operating characteristic analysis. 724 Am J Clin Pathol 2011;136:721-726 724 DOI: 10.1309/AJCPFB6EXO7BJVLR

Hematopathology / Original Article Patient s Weight (kg) 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 Because CD34+ cell determination demands significant time and resources, we used our data for applying ROC curve analysis to validate current CB parameters as surrogates for CD34+ cell counting and ability to provide reliable, effective, and cost-effective criteria for the appropriate identification of CB units suitable for transplantation, avoiding the cost of processing units with a high probability of not having the required CD34+ cell content for cryopreservation and grafting purposes. We confirmed that the TNC count is the parameter that better correlates with the CD34+ cell content in UCB, in agreement with previous reports. 26,31,32 ROC curve analysis validated the current standard of TNC content of 8 10 8 or more as an appropriate cutoff parameter for the selection of CB units containing an adequate number of CD34+ MNCs for cryopreservation for grafting purposes. From the Hematology Department, Internal Medicine Division, Dr. José Eleuterio González University Hospital of the School of Medicine of the Autonomous University of Nuevo León, Monterrey, México. Address reprint requests to Dr Jaime-Pérez: Servicio de Hematología, Hospital Universitario Dr. José E. González, Edificio Dr. Rodrigo Barragán, 2 piso, Avenida Madero y Gonzalitos S/N, Colonia Mitras Centro, Monterrey, Nuevo León, México, CP 64460. References 1. Weeks FM, Yee GC, Bartfield AA, et al. The true cost of bone marrow t ransplantation. Am J Med Sci. 1997;314:101-112. 2. Wagner JE, Kernan NA, Steinbuch M, et al. Allogeneic sibling umbilical -cord-blood transplantation in children with malignant and non-malignant disease. Lancet. 1995;346:214-219. Percentage of Acceptable Cord Blood Units CD34+ cell counting TNC count cutoff 0.0 20.0 40.0 60.0 80.0 100.0 Figure 3 Percentage of cord blood units that would be available for transplantation as a function of patient weight using units meeting a CD34+ cell count 2 10 6 determined by flow cytometry before cord blood cryopreservation, compared with the application of the parameter total nucleated cell (TNC) count 8.32 10 8 selected by receiver operating characteristic curve analysis. 3. Gluckman E, Rocha V, Boyer-Chammard A, et al, for the Eurocord Transpl ant Group and the European Blood and Marrow Transplantation Group. Outcome of cord-blood transplantation from related and unrelated donors. N Engl J Med. 1997;337:373-381. 4. Rubinstein P, Carrier C, Scaradavou A, et al. Outcomes among 562 recip ients of placental-blood transplants from unrelated donors. N Engl J Med. 1998;339:1565-1577. 5. Kurtzberg J, Laughlin M, Graham ML, et al. Placental blood as a source of hematopoietic stem cells for transplantation into unrelated recipients. N Engl J Med. 1996;335:157-166. 6. McKenna DH, Brunstein CG. Umbilical cord blood: current status and fut ure directions. Vox Sang. 2011;100:150-162. 7. Brocklebank AM, Sparrow RL. Enumeration of CD34+ cells in cord blood: a variation on a single-platform flow cytometric method based on the ISHAGE gating strategy. Cytometry. 2001;46:254-261. 8. Holyoake TL, Alcorn MJ. CD34+ positive haemopoietic cells: biology and clinical applications. Blood Rev. 1994;8:113-124. 9. Solves P, Carbonell-Uberos F, Mirabet V, et al. CD34+ cell content for selecting umbilical cord blood units for cryopreservation. Transfusion. 2007;47:552-553. 10. Van Haute I, Lootens N, De Buck K, et al. Selecting cord blood units for storage by CD34+ cell counts. Transfusion. 2005;45:455-457. 11. Wu JY, Liao C, Xu ZP, et al. Banking and transplantation of umbilical cord blood in Guangzhou, China. Cytotherapy. 2006;8:488-497. 12. Novelo-Garza B, Limon-Flores A, Guerra-Marquez A, et al. Establishing a cord blood banking and transplantation program in Mexico: a single institution experience. Transfusion. 2008;48:228-236. 13. Wagner JE, Barker JN, DeFor TE, et al. Transplantation of unrelated d onor umbilical cord blood in 102 patients with malignant and nonmalignant diseases: influence of CD34 cell dose and HLA disparity on treatment-related mortality and survival. Blood. 2002;100:1611-1618. Am J Clin Pathol 2011;136:721-726 725 725 DOI: 10.1309/AJCPFB6EXO7BJVLR 725

Jaime-Pérez et al / Umbilical Cord Blood Selection 14. Barker JN, Weisdorf DJ, DeFor TE, et al. Transplantation of 2 partial ly HLA-matched umbilical cord blood units to enhance engraftment in adults with hematologic malignancy. Blood. 2005;105:1343-1347. 15. Zweig MH, Campbell G. Receiver-operating characteristic (ROC) plots: a fundamental evaluation tool in clinical medicine. Clin Chem. 1993;39:561-577. 16. Hanley JA, McNeil BJ. The meaning and use of the area under a receive r operating characteristic (ROC) curve. Radiology. 1982;143:29-36. 17. Solves P, Perales A, Mirabet V, et al. Optimizing donor selection in a cord blood bank. Eur J Haematol. 2004;72:107-112. 18. Urciuoli P, Passeri S, Ceccarelli F, et al. Pre-birth selection of um bilical cord blood donors. Blood Transfus. 2010;8:36-43. 19. Tamburini A, Malerba C, Picardi A, et al. Placental/ umbilical cord bl ood: experience of St. Eugenio Hospital collection center. Transplant Proc. 2005;37:2670-2672. 20. Rubinstein P, Taylor PE, Scaradavou A, et al. Unrelated placental blo od for bone marrow reconstitution: organization of the placental blood program. Blood Cells. 1994;20:587-600. 21. Sutherland DR, Anderson L, Keeney M, et al, for the International Soc iety of Hematotherapy and Graft Engineering. The ISHAGE guidelines for CD34+ cell determination by flow cytometry. J Hematother. 1996;5:213-226. 22. Akobeng AK. Understanding diagnostic tests 1: sensitivity, specificit y and predictive values. Acta Paediatr. 2007;96:338-341. 23. Knottnerus JA, van Weel C, Muris JW. Evaluation of diagnostic procedu res. BMJ. 2002;324:477-480. 24. Choi BC. Slopes of a receiver operating characteristic curve and like lihood ratios for a diagnostic test. Am J Epidemiol. 1998;148:1127-1132. 25. Dwyer AJ. In pursuit of a piece of the ROC. Radiology. 1996;201:621-625. 26. Jan RH, Wen SH, Shyr MH, et al. Impact of maternal and neonatal facto rs on CD34+ cell count, total nucleated cells, and volume of cord blood. Pediatr Transplant. 2008;12:868-873. 27. Hutton EK, Hassan ES. Late vs early clamping of the umbilical cord in full-term neonates: systematic review and meta-analysis of controlled trials. JAMA. 2007;297:1241-1252. 28. Skoric D, Balint B, Petakov M, et al. Collection strategies and cryop reservation of umbilical cord blood. Transfus Med. 2007;17:107-113. 29. Meyer TP, Hofmann B, Zaisserer J, et al. Analysis and cryopreservatio n of hematopoietic stem and progenitor cells from umbilical cord blood. Cytotherapy. 2006;8:265-276. 30. Koliakos G, Alamdari DH, Tsagias N, et al. A novel highyield volume- reduction method for the cryopreservation of UC blood units. Cytotherapy. 2007;9:654-659. 31. Solves P, Perales A, Moraga R, et al. Maternal, neonatal and collecti on factors influencing the haematopoietic content of cord blood units. Acta Haematol. 2005;113:241-246. 32. Nakagawa R, Watanabe T, Kawano Y, et al. Analysis of maternal and neonatal factors that influence the nucleated and CD34+ cell yield for cord blood banking. Transfusion. 2004;44:262-267. 726 Am J Clin Pathol 2011;136:721-726 726 DOI: 10.1309/AJCPFB6EXO7BJVLR