Usefulness of New CT Technologies for Interventional Cardiovascular Procedures

Similar documents
Ultrasound. Computed tomography. Case studies. Utility of IQon Spectral CT in. cardiac imaging

Alessandro Albonico Philips

Cardiac Computed Tomography

Les Outils Cliniques de Demain en Scanner Cardiaque. Cardiaque Status en ECR 2018 From Diagnosis to Prognosis

Pushing the limits of cardiac CT. Steven Dymarkowski Radiology / Medical Imaging Research Centre

Cardiac CT - Coronary Calcium Basics Workshop II (Basic)

New Cardiovascular Devices and Interventions: Non-Contrast MRI for TAVR Abhishek Chaturvedi Assistant Professor. Cardiothoracic Radiology

New Technologies for Cardiac CT. Geoffrey D. Rubin, MD, MBA, FACR, FNASCI Duke University

Dual-Energy CT: The Technological Approaches

Validation of CT Perfusion Imaging Against Invasive Angiography and FFR on a 320-MDCT Scanner

Cardiac Imaging Tests

Dr Winnie Sze-Wun Chan. Cardiac Team Deputy Team Head Department of Radiology and Imaging Queen Elizabeth Hospital Hong Kong

Low Dose Era in Cardiac CT

Imaging congestive heart failure: role of coronary computed tomography angiography (CCTA)

Updates on Coronary Angiography Rotational Angiography, 3-D Modeling, and

Disclosure Information

Imaging Strategies for Endovascular Cardiovascular Procedures and Percutaneous Aortic Valves. Roy K Greenberg, MD

Combined Anatomical and Functional Imaging with Revolution * CT

The radiation dose in retrospective

Typical PET Image. Elevated uptake of FDG (related to metabolism) Lung cancer example: But where exactly is it located?

Noncoronary Cardiac MDCT

Certainty. lives in layers. Philips IQon Spectral CT. Computed tomography

2/10/2012. The Role of Multimodality Imaging in Percutaneous Valve Interventions. This is truly a TEAM work. Overview. Overview

General Cardiovascular Magnetic Resonance Imaging

Scientific Exhibit. Authors: D. Takenaka, Y. Ohno, Y. Onishi, K. Matsumoto, T.

University of Groningen. Quantitative CT myocardial perfusion Pelgrim, Gert

Image Assistance in TAVI Why CT? Won-Jang Kim, MD, PhD Clinical Assistant Professor of Medicine, Heart Institute, Asan Medical Center, Seoul, Korea

, David Stultz, MD. Cardiac CT. David Stultz, MD Cardiology Fellow, PGY 6 March 28, 2006

Fellows on this rotation are expected to attend nuclear conferences and multimodality imaging conference.

An Introduction to Dual Energy Computed Tomography

ECG Gated CT Aorta in Transcatheter Aortic Valve Implantation

Coronary Artery Imaging. Suvipaporn Siripornpitak, MD Inter-hospital Conference : Rajavithi Hospital

Dual Energy CT of the Heart: Perfusion and Beyond

Dual-Energy 101: Principles, Methods and Dose

The correlation of AVA measured by transthoracic, transesophageal echocardiography and cardiac CT

CT SCAN PROTOCOL. Shoulder

Multisclice CT in combination with functional imaging for CAD. Temporal Resolution. Spatial Resolution. Temporal resolution = ½ of the rotation time

Pre-procedural CT angiography for Transcatheter Aortic Valve Implantation: What a Radiologist Needs to Know?

X-Ray & CT Physics / Clinical CT

The Final 10-Year Follow-up Results from the Bari Randomized Trial J Am Coll Cardiol (2007) 49;1600-6

State-of-the-Art SPECT/CT: Cardiac Imaging

Low-dose and High-resolution Cardiac Imaging with Revolution CT

Integration of CT and fluoroscopy images in the ablative treatment of atrial fibrillation

Fundamentals of Nuclear Cardiology. Terrence Ruddy, MD, FRCPC, FACC

Severity of AS Degree of AV calcification (? Bicuspid AV), annulus size, & aortic root

Imaging in TAVI. Jeroen J Bax Dept of Cardiology Leiden Univ Medical Center The Netherlands Davos, feb 2013

True Dual Energy. Dr. Stefan Ulzheimer, Siemens Healthcare GmbH. DEfinitely Siemens

Horizon Scanning Technology Summary. Magnetic resonance angiography (MRA) imaging for the detection of coronary artery disease

A Snapshot on Nuclear Cardiac Imaging

SPECT-CT: Τι πρέπει να γνωρίζει ο Καρδιολόγος

Photon Attenuation Correction in Misregistered Cardiac PET/CT

CT Myocardial Perfusion: Is there Added Value to Coronary CT?

Low-dose prospective ECG-triggering dual-source CT angiography in infants and children with complex congenital heart disease: first experience

Cardiac CT Techniques in Neonates (and infants)

MSRS 6473 Vascular Noninvasive Imaging Procedures

Simon Nepveu 1, Irina Boldeanu 1, Yves Provost 1, Jean Chalaoui 1, Louis-Mathieu Stevens 2,3, Nicolas Noiseux 2,3, Carl Chartrand-Lefebvre 1,3

Optimal Imaging Technique Prior to TAVI -Echocardiography-

Outline. EuroScore II. Society of Thoracic Surgeons Score. EuroScore II

Feasibility of a New C-arm angiography (DYNA-CT) based three-dimensional algorithm in combination with myocardial perfusion assessment

Varian Edge Experience. Jinkoo Kim, Ph.D Henry Ford Health System

Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement

Dual-Energy CT Applications in Radiation Therapy

Cardiac MRI in ACHD What We. ACHD Patients

Integrated PET/CT systems State of the art and Clinical Applications

Recent Advancement of Cardiac CT

Utility of CT angiography for pre-operative evaluation of robotic-assisted minimally invasive mitral valve surgery.

Coronary Artery Anomalies from Birth to Adulthood; the Role of CT Coronary Angiography in Sudden Cardiac Death Screening

THE ROLE OF HIGH END MULTI DETECTOR CT IN CORONARY IMAGING ESSAY

A new method for radiation dose reduction at cardiac CT with multi-phase data-averaging and non-rigid image registration: preliminary clinical trial

Preprocedural evaluation for TAVR

Dr Felix Keng. Imaging of the heart is technically difficult because: Role of Cardiac MSCT. Current: Cardiac Motion Respiratory Motion

Computed tomography. Department of Radiology, University Medical School, Szeged

cardiac imaging planes planning basic cardiac & aortic views for MR

The 5th Congress of Asian Society of Cardiovascular Imaging

Triple Rule-out using 320-row-detector volume MDCT: A comparison of the wide volume and helical modes

Echo Assessment Pre-TAVI

Εξελίξεις και νέες προοπτικές στην καρδιαγγειακή απεικόνιση CT. Σταμάτης Κυρζόπουλος Ωνάσειο Καρδιοχειρουργικό Κέντρο

Recent developments in cardiac CT

CT Scanning Protocol For V2R Guided Surgery Solutions

Aortic valve calcium load before TAVI: Is it important?

CT Imaging of Atherosclerotic Plaque. William Stanford MD Professor-Emeritus Radiology University of Iowa College of Medicine Iowa City, IA

Computed Tomography of the Coronary Arteries

CARDIAC MRI. Cardiovascular Disease. Cardiovascular Disease. Cardiovascular Disease. Overview

B-Flow, Power Doppler and Color Doppler Ultrasound in the Assessment of Carotid Stenosis: Comparison with 64-MD-CT Angiography

CT Perfusion. U. Joseph Schoepf, MD, FAHA, FSCBT MR, FSCCT Professor of Radiology, Medicine, and Pediatrics Director of Cardiovascular Imaging

Perspectives of new imaging techniques for patients with known or suspected coronary artery disease

Index. radiologic.theclinics.com. Note: Page numbers of article titles are in boldface type.

Protocols in Cardiac CT Dr. Bruce Precious Dalhousie University Friday, April 15, 2016

Imaging of the Heart Todd Tessendorf MD FACC

Technology Assessment Institute: Summit on CT Dose Cardiac CT - Optimal Use of Evolving Scanner Technologies

CT angiography techniques. Boot camp

Cardiac Imaging. Kimberly Delcour, DO, FACC. Mahi Ashwath, MD, FACC, FASE. Director, Cardiac CT. Director, Cardiac MRI

THE TUFFEST STUFF CT REGISTRY REVIEW Live Lecture Seminar SATURDAY CURRICULUM

Comments restricted to Sapien and Corevalve 9/12/2016. Disclosures: Core Lab contracts with Edwards Lifesciences, Middlepeak, Medtronic

Neuroprotection During TAVR

Cigna - Prior Authorization Procedure List Cardiology

Disclosures. GETTING TO THE HEART OF THE MATTER WITH MULTIMODALITY CARDIAC IMAGING Organ Review Meeting 25 September. Overview

Bone Densitometry Radiation dose: what you need to know

GE Healthcare. Rad Rx. White Paper

CT Myocardial Perfusion

Transcription:

Usefulness of New CT Technologies for Interventional Cardiovascular Procedures Ronen Rubinshtein, MD FACC FESC Department of Cardiovascular Medicine Lady Davis Carmel Medical Center & Technion Israel Institute of Technology Haifa, Israel

Relevant Disclosures Departmental research grant Philips P.I Arineta

Outline 1. Fusion imaging for structural heart interventions 2. Dual energy / Spectral CT for CV imaging 3. Early access with a compact cardiac-oriented CT

1. Fusion Imaging in Multimodality Medical Imaging - Principles Why? To combine the relative diagnostic advantages of two different modalities into a single screen shot (static or real time) How? by creating a grid for each image acquired in each modality and then linking each pixel in the two modalities via a similarity function

Fusion Imaging Principles cont. Alternatively, linking hinge points or common easy to find markers which can be linked in both studies For example hepatic veins in liver imaging (U/S + MRI)

Principles of Image Co-Registration Rigid registration: combining two acquisitions and 2 similar anatomic grids - for example: 2 repeated head CT s Elastic registration: changing / bending the grid points of one image to fit the grid of the other modality (to allow easier anatomic 3D visualization, not necessarily for quantitative analysis)

Real Time Co-Registration (2 simultaneous cine loops) Clinical need is unclear Requires extremely fast computer algorithms Most cardiac CT co-registration algorithms do not require multi-phasic acquisition (i.e. retrospective gating)

Image Fusion for CV Procedures Electrophysiology - EP Lab Integration Automatic Heart Segmentation 3D Image Data Left Atrium & PV Assessment EP Planning

Structural Heart Interventions TAVI - Transcatheter Aortic Valve Implantation TAVI is non-inferior (Partner 5 years study) or superior (CoreValve 2 year study) to surgical AVR in high risk AS patients TAVI is usually performed under fluoroscopic and sometimes with echocardiographic guidance Structural heart disease intervention (TAVI, LAA occlusion, trancatheter mitral valve repair) are estimated to grow at an annual rate of 30%

CT TAVI Planning PC Based Portal Application Automated generation of most commonly needed planes required for TAVI planning the coronary ostia automated planes detection and dimensions measurements of the aortic annulus left ventricular outflow tract (LVOT) sinotubular junction sinus of valsalva ascending aorta and distance to coronary ostia for TAVI-device sizing 10

TAVI planning (IntelliSpace portal) C-arm angle for deployment Korosoglou G, et al. Catheterization and Cardiovascular interventions, 2013; 148-59 :)1( 81

Emerging Application CT-TAVI

TAVI Planning

Preparing the CT Image for TAVI Heart-Navigator (may be useful for both native and VIV TAVI)

CT- Cath Lab Integration Aorta Extraction & Analysis 3D Image Data CT-TAVI Planning

Typical Use of Fusion Imaging for TAVI

2. Material Specific Imaging (Dual Energy / Spectral CT) Use each tube at a different kv to exploit the kv-dependent nature of CT # Off-line post-processing for material / disease selective images

Attenuation Dual Energy: What is it? Significant difference in the linear attenuation coefficient at two different energies 1.0E+02 1.0E+01 56 kv 76 kv Iodine Bone Large increase 1.0E+00 Small increase 1.0E-01 10 30 50 70 90 Energy / kev 110 130 150

80 kv Material Decomposition 140 kv Iodine CT value @ 80 kv Fat Tissue Iodine 65 0 Tissue -100 Fat -90 0 60 CT value @ 140 kv Characterization of different tissue types

From: New Applications of Cardiac Computed Tomography: Dual-Energy, Spectral, and Molecular CT Imaging J Am Coll Cardiol Img. 2015;8(6):710-723. doi:10.1016/j.jcmg.2015.03.005 Figure Legend: Schematic Illustration of 4 Different Approaches for Obtaining Dual-Energy Information (A) Dual source-detector pairs with each source operating at a different tube voltage. Each x-ray source covers a different scan field. (B) Single source-detector pair with the source capable of rapid voltage switching in a single gantry rotation. (C) Single sourcedetector pair with a dual-layer detector made of 2 different materials capable of differentiating between low-energy (upper layer) and high-energy (bottom layer) photons, with the source operating at constant tube voltage. (D) Single source-detector pair with tube voltage switching between sequential gantry rotations. Date of download: 7/3/2015 Copyright The American College of Cardiology. All rights reserved.

HighE LowE Photo-Diode Tungsten The IQon Detector 16 16 2 tile with the same pitch as ict 16x16 2 Tile Top layer scintillator optimized for absorbing low energy photons No spectral filtering in detection pass i.e. no photons lost Light collected from the side of the scintillator to improve the coupling of light to the photo-diode Tungsten backbone protects the photo diode from X-ray, minimizes cross talk between detectors and provides mechanical robustness 2mm thick (in ict 1.4mm) bottom layer (GOS) scintillator for absorbing >99% of the incident photons substrate The Low E scintillator (low density Garnet): Spectral properties High light output Low Afterglow Good temperature stability

SPECTRAL CT Nano-panel Prism: Converting X-RAY to Visible Light

Energy Map with uric acid and bone slopes Bone 23

Spectral CT: Gout

IQon Spectral CT: Step & Shoot Cardiac reconstructed at different energy levels Courtesy: University Hospitals Case Western Reserve, Cleveland, OH

IQon Cardiac CT Contrast enchantment with mono-energy images MonoE 50keV MonoE 70keV MonoE 90keV MonoE 140keV Courtesy: University Hospitals Case Western Reserve, Cleveland, OH

Improved contrast enhancement 20 cc s of IV contrast 20 cc s of IV contrast WATER NO IODINE Conventional 120kVp 40 kev Courtesy: Dr. H Bezerra, Dr. RC Gilkeson, University Hospitals, Cleveland, OH

Coronary Stenosis Assessment Reduced Calcium Blooming Slide 4 Clinical 7 120kVp 200keV 120kVp 200keV Courtesy: University Hospitals Case Western Reserve, Cleveland, OH

Spectral / Dual-Energy CT for the Evaluation of Coronary Atherosclerosis

3. Cardiac Oriented CT Scanner Background Cardiac CT Angiography became a valid option since the introduction of multi row 16, 40 and 64 slice CT scanners To date, all procedures are done on whole body scanners designed and built for general purpose imaging A new type of Stereo CT dual tube scanner optimized for cardiovascular imaging is under evaluation

CCTA has to show good image quality Because other modalities have better spatial resolution CT Angiography Angiography IVUS OCT Resolution : 230-600µm 200µm 100µm 10µm

Stereo CT Technology Two overlapping cone beams facing a single detector array rotate about the patient Coverage sufficient for whole heart scanning in a single beat

Animal Model Results LAD

Cardiac Oriented CT in the CCU Lady Davis Carmel Medical Center Haifa, Israel

First Human Case of CCTA Arineta December 2015 RCA LCX LAD

Spectral CT A story from the holy land Is this rock the first man-made art? NYTIMES: Anthropologists discovered a 55,000-year-old skull fossil in the Manot Cave in western Galilee in 2008, and it was subjected to years of analysis.

Spectral CT in the service of Archeology D B C B A A ~40,000 years old stone from Manot cave, Israel with human made engravings. A CT scan enabled us to reveal the difference between natural cracks (A) and human intended engraving (3B) in the stone. The interruption in the continuity of the crust (C) opposed to natural cracks (D) emphasis the intended human actions. Courtesy of Tel Aviv University

Usefulness of New CT Technologies for Interventional Cardiovascular Procedures Summary Rigid or Elastic co-registration allow image fusion from two different datasets or two different modalities Fusion imaging may be helpful to plan or guide CV interventions in patients with structural heart diseases Use of multiple tube outputs or dedicated detectors allow better assessment of the cardiac tissue Material specific assessment with spectral CT may improve diagnostic accuracy and possibly overcome common CT artifacts for vascular / coronary CTA and myocardial perfusion imaging Cardiac dedicated stereo-ct may increase the use of CT technology by interventional cardiologists Lady Davis Carmel Cardiovascular Center

Thank you