Agilent 7700x ICP-MS

Similar documents
New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

Mass Spectrometry at the Laboratory of Food Chemistry. Edwin Bakx Laboratory of Food Chemistry Wageningen University

SCS Mass Spectrometry Laboratory

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Mass Spectrometry. Actual Instrumentation

Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system

Fast and easy separation of 23 drugs of abuse. including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS

Impurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF

Determination of Amantadine Residues in Chicken by LCMS-8040

Detection of oxygenated polycyclic aromatic hydrocarbons (oxy-pahs) in APCI mode with a single quadrupole mass spectrometer

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate

Comprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids

Bioanalytical Quantitation of Biotherapeutics Using Intact Protein vs. Proteolytic Peptides by LC-HR/AM on a Q Exactive MS

Components of a Mass Spectrometer

Sample Concentration and Analysis of Human Hormones in Drinking Water

New Instruments and Services

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

Edgar Naegele. Abstract

Application Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer

Ion Source. Mass Analyzer. Detector. intensity. mass/charge

LOCALISATION, IDENTIFICATION AND SEPARATION OF MOLECULES. Gilles Frache Materials Characterization Day October 14 th 2016

Measuring Phytosterols in Health Supplements by LC/MS. Marcus Miller and William Schnute Thermo Fisher Scientific, San Jose, CA, USA

New Mass Spectrometry Tools to Transform Metabolomics and Lipidomics

LC-MS/MS quantitative analysis of Polyunsaturated Omega 3, 6,7 and 9 Fatty Acids in Serum for

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Integration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation

Analysis of Pesticides (II) Metribuzin & their metabolites in Rice Jun Yonekubo, Nihon Waters, JAPAN

Using Software Tools to Improve the Detection of Impurities by LC/MS. Application Note. Christine Miller Agilent Technologies.

Separation of Polyphenols by Comprehensive 2D-LC and Molecular Formula Determination by Coupling to Accurate Mass Measurement

Agilent 1260 Infinity Analytical SFC System

Supporting information

Vitamin D3 and related compounds by ESI and APCI

Don t miss a thing on your peptide mapping journey How to get full coverage peptide maps using high resolution accurate mass spectrometry

Residual Solvents in medical cannabis analysis using the SRI 8610C FID GC Jan 2017

Polymer Additive Analysis by EI and APCI

Method Development for the Analysis of Endogenous Steroids Using Convergence Chromatography with Mass Spectrometric Detection

Quantitative Analysis of Drugs of Abuse in Urine using UHPLC Coupled to Accurate Mass AxION 2 TOF Mass Spectrometer

Enhanced Detection Capabilities in Speciation Analysis Using a Highly Sensitive ICP-MS. Peio RISS ICP-MS Application Specialist.

MALDI-TOF. Introduction. Schematic and Theory of MALDI

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

LCMS-8030 Application Report. Steroids: Testosterone, Progesterone, Estradiol, Ethinylestradiol

Agilent s LC/MS Portfolio and Applications Examples

Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices

Metabolomics: quantifying the phenotype

More structural information with MS n

Introduction to the Oligo HTCS Systems. Novatia, LLC

Identification of Steroids in Water by Ion Trap LC/MS/MS Application

Dry eye disease commonly known as atopic keratoconjunctivitis is an autoimmune disease of

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Results of Using Re-washed Vials and Closures

Designing an Extractables and Leachables Study

Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System

Qualitative and quantitative determination of cannabinoid profiles and potency in CBD hemp oil using LC/UV and Mass Selective Detection

Determination of Aflatoxins in Food by LC/MS/MS. Application. Authors. Abstract. Experimental. Introduction. Food Safety

Quantitative Analysis of Opiates in Urine Using RRHT LC/MS/MS. Application. Authors. Introduction. Abstract. Forensics

The Investigation of Factors Contributing to Immunosuppressant Drugs Response Variability in LC-MS/MS Analysis

ANALYTICAL SCALE AGILENT LCMS SYSTEMS OPERATIONAL QUALIFICATION

Lipidomic Analysis by UPLC-QTOF MS

Analysis of the Non-Ionic Surfactant Triton-X Using UltraPerformance Convergence Chromatography (UPC 2 ) with MS and UV Detection

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079

Methods in Mass Spectrometry. Dr. Noam Tal Laboratory of Mass Spectrometry School of Chemistry, Tel Aviv University

Mass Spectrometry Course Árpád Somogyi Chemistry and Biochemistry MassSpectrometry Facility) University of Debrecen, April 12-23, 2010

Identification and Quantification at ppb Levels of Common Cations and Amines by IC-MS

Agilent 1220 Infinity LC System Performance Specifications

High-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.

AppNote 4/2002. Stir Bar Sorptive Extraction: Capacity and Competition Effects KEYWORDS ABSTRACT. SBSE, SPME, capacity

Analysis of Peptides via Capillary HPLC and Fraction Collection Directly onto a MALDI Plate for Off-line Analysis by MALDI-TOF

Author. Introduction. Abstract

Improving Selectivity in Quantitative Analysis Using MS 3 on a Hybrid Quadrupole-Linear Ion Trap Mass Spectrometer

Automated Sample Preparation/Concentration of Biological Samples Prior to Analysis via MALDI-TOF Mass Spectroscopy Application Note 222

Application Note. Small Molecule Pharmaceuticals. 2-Ethyl-2-phenylmalonamide Ethosuximide Primidone Carbamazepine. Carbamazepine-

Join the mass movement towards mass spectrometry

Quantification of lovastatin in human plasma by LC/ESI/MS/MS using the Agilent 6410 Triple Quadrupole LC/MS system

Designer Fentanyls Drugs that kill and how to detect them. Cyclopropylfentanyl

Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis

Performance characteristics of the Agilent 1100 Series preparative pump. Technical Note. Abstract

Authors. Abstract. Introduction. Environmental

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations

Development and Validation of a Liquid Chromatography- Mass Spectrometry method for analysis of Oxysterols in Human Plasma

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual

Metabolomics Strategies

New Instruments and Services

[ APPLICATION NOTE ] Profiling Mono and Disaccharides in Milk and Infant Formula Using the ACQUITY Arc System and ACQUITY QDa Detector

ANALYTICAL REPORT 1 3C-P (C14H23NO3) 1-(3,5-dimethoxy-4-propoxylphenyl)propan-2-amine.

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages

Enhanced LC-MS Sensitivity of Vitamin D Assay by Selection of Appropriate Mobile Phase

Go beyond. to realities unexplored. Comprehensive workflows, integrated solutions

Fundamentals of Soft Ionization and MS Instrumentation

ANALYTICAL REPORT 1. N-methyl-2AI ( C10H13N) Remark other NPS detected: none. N-methyl-2,3-dihydro-1H-inden-2-amine. Sample ID:

ANALYTICAL REPORT 1. bk-2c-b ( C10H12BrNO3) 2-amino-1-(4-bromo-2,5-dimethoxyphenyl)ethan-1-one

Gradient Elution LC-MS/MS Determination of Gefitinib in Rat Plasma and its Pharmacokinetic Study

Fat-Soluble Vitamins Analysis on an Agilent ZORBAX Eclipse PAH Polymeric C18 Bonded Column

Characterization of an Unknown Compound Using the LTQ Orbitrap

Sci Pharm

Transcription:

Agilent 7700x ICP-MS Metals analysis Mid ppt to low ppb detection range Option to detect in four different gas modes to gain optimum detection of multiple metals or interferences in a sample Autosampler can hold 21, 50 ml falcon tubes and 180, 15 ml falcon tubes

Shimadzu 8040 LC-Triple Quadrupole MS with PDA and Fluorescence Detection Nexera X2 LC-30AD UHPLC system with a binary solvent system ESI triple quadrupole mass spectrometer SPD-M30A diode array detector RF-20A XS fluorescence detector Quantitative analysis or structural elucidation of small molecules Mid ppt to low ppb detection limits Mass Range: 50 2000 Da Temperature controlled autosampler holds 324, 2 ml RAM vials Column oven Acquired through Shimadzu Grant.

Thermo Scientific Altis LC-Triple Quadrupole MS UltiMate 3000 UHPLC System with a binary solvent system which allows 4 different mobile phases, but only 2 at a time. TSQ Altis ESI triple quadrupole mass spectrometer Online concentration capabilities Online concentration detection range in low ppt Standard detection range mid ppt to low ppb Mass Range: 5 2000 Da Temperature controlled autosampler holds 162, 2 ml RAM vials, and 30, 10 ml vials and column oven Run by laboratory staff only and primarily used for large projects

Thermo Scientific LTQ Orbitrap XL with Nano LC and HPLC capabilities High resolution mass spectrometer. o Resolution 60,000 at m/z 400 at a scan rate of 1 Hz o Up to 100,000 resolution o External calibration and lock mass for 1 ppm error. Easy nano LC 1200 Waters Alliance HT 2795 HPLC with temperature controlled autosampler which holds 144, 2 ml RAM vials and column oven. o Quaternary pump up to 4,500 psi. Mass Range o Linear Ion trap: 50-2000 m/z o Orbi-Trap: 200-4000 m/z Sensitivity sub-femtomol range for peptides

Bruker UltrafleXtreme MALDI-TOF/TOF 300-350 kda mass range with linear mode. 300-6 kda mass range with reflection mode and LIFT fragmentation. CID or LID to analyze structure of proteins, RNA/DNA, and polymers. FlexImaging for MALDI Imaging Mass Spectrometry. BioTools for protein identification on Mascott database. BioTyper for bacteria culture Identification. SCiLs software package for 3D imaging and statistical analysis.

Waters 2695/ZQ Waters 2695 HPLC with temperature controlled autosampler which holds 120, 2 ml RAM vials and column oven. 4500 psi maximum pressure quaternary pump. ESI source with quadrupole analyzer from 50-2000 Da. Source fragmentation by adjustable cone voltage. Nominal mass accuracy for direct injection or chromatographic analysis. 20 ng/ml to 10 μg/ml; Acetonitrile, Methanol, Water, or Isopropanol.

Agilent 6890/5973 - Semivolatiles Automatic Liquid Sampler holds 100, 2 ml RAM vials. EI source and quadrupole analyzer from 10-600 Da Rxi-5ms column for walk up analysis of organic reactions and quantitative analysis of semivolatiles. Chemstation software and NIST database searching of fragmentation patterns. Optional CDS8000 Thermal Desorption, Purge and Trap, and Pyrolyzer.

Agilent 6890/5973 Volatiles EI source and quadrupole analyzer from 10-600 Da or FID. Restek RTX-Volatiles column Chemstation software and NIST database searching of fragmentation patterns. Optional CDS8000 Thermal Desorption, Purge and Trap, and Pyrolyzer. Optional Solatek 72 Purge and Trap autosampler with Velocity XPT Concentrator. Optional manual SPME analysis.

CDS8000 Concentrator Manual Purge and Trap. Manual thermal desorption tube sampling from active air sampling unit. Bulk headspace analysis options: 10 x 9.5 cm Large BDHS 13 x 3 cm (a silanized steel tray is available that sits in the center of the tube long ways, for height of 1.5 cm) 15 x 1.5 cm testube sampler Cryofocusing available.

Solatek 72 Purge and Trap with Velocity XPT Concentrator 72 vial autosampler for 40 ml purge and trap vials. In vial purge with heated sampler and stirring for soils and sludges. Add 0-20 ml of water before sampling vapor. 10 ml purge and trap liquid sampling sparging vessel. 3 Optional internal standard or calibrant addition vials online.

Perkin Elmer Clarus 580/Turbomatrix 40 Headspace GC-FID-ECD 40 vial autosampler for headspace analysis. Preheats samples during GC run to save time. Flame Ionization Detector and Electron Capture Detectors available. Minimum sample temperature of 35 C

Waters 2695/996 PDA Waters 2695 HPLC with 120 sample autosampler with column oven. 4500 psi maximum pressure quaternary pump. UV detector with Empower software package for quantitative analysis.