RiGO801 Laboratory Requirements

Similar documents
LMT-Goniophotometer GO-H 1400 Goniophotometer System for Measurement of Automotive Lamps

Goniometer series 400

Dynamic Hollow Cylinder System Proposal

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

AMS 200. Goniophotometer for small to medium-sized lamps and modules

Geräteblatt Pallazza III PGI

Nuclear Associates

Solar Illumination Study

SED2 VFD NEMA Type 3R Bypass, and Type 3R Harsh Environment (3RHE) Bypass

We bring quality to light. LGS 1000 Goniophotometer

1 Service factor Determine the required service factor from tables 9 and 10 on pages 87 and 88.

Datasheet BR Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors

We bring quality to light. LGS 350 Goniophotometer

R-Group Finland Oy. RLS Lifting Sockets Technical Manual According to Eurocodes, EU Machinery directive 2006/42/EC and VDI/BV-BS 6205 CE Approved

Multipower. User Guide E S S E N T I A L S T R E N G T H

Convex Array Transducer

3. Dimensions, weights Placement and Assembly Pressure drops Noise data Material... 14

Linear Array Transducer

2YEARS. three-phase kVA. Digital voltage stabiliser Orion Plus. Standard features. Voltage stabilisation PC selectable output voltage

RL/B MZ SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL RL 300/B MZ RL 400/B MZ. 600/ kw 1000/ kw

Mini UPS and Power Sensor. Power Output Cord. Power Input Port. Switch Port

Side Channel R ing Blower

Low Row. User manual E S S E N T I A L S T R E N G T H

High Grade Universal Testing Machines

MIE Medical Research Ltd Digital Analyser - Myometer Instruction Manual

NC DOUBLE OPPOSING HEAD DRILL

Liquid ring vacuum pumps single-stage

RLS/E-EV MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES

Alignment and Calibration of the APEX Instrument. March 30, Chemical Crystallography Laboratory

N4i Installation Manual. (picture of N4i screen)

Active Imaging TM transducers: Active Imaging 3-IN-1 Active Imaging SideScan

Motorized Precision Goniometer

1 Study the drawings and the installation. 2 Ensure that you have the correct components. 3 Follow the manufacturer s instructions

...vibration isolation. Mounts

Technical Data Sheet SONOFLOW CO.55 V1.0

Convex Array Transducer

RLS/BP MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES. RLS 300/BP MX 600/ kw RLS 400/BP MX 800/ kw DUAL FUEL.

SaeboMAS (Patent Pending)

High Frequency Linear Array Transducer

1724 Lab: Frog Skeletal Muscle Physiology (Marieb Exercise 16A) Marieb/iWorx / Ziser, 2002

Technical Data Sheet SONOFLOW CO.55/xxx(H) V2.0

DEVICE FOR MUSCLE COORDINATION IMPROVEMENT

Mini External Fixator.

E200 ORT - Optical Rotary Torque Transducer. Contents

Descriptions of NDT Projects Fall 2004 October 31, 2004

Instruction Manual Aerogen, Inc. Part No. AG-AL1010 Rev. C

USER MANUAL CAUTION. MADE IN CHINA 2015 Body Action Enterprise Co., Ltd. All rights reserved.

CORESTA RECOMMENDED METHOD N 22

OWNER S MANUAL and INSTALLATION INSTRUCTIONS

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP

DSI Series Installation

A-dec 372L or 572L Dental Light on an A-dec Performer Dental Chair INSTALLATION GUIDE

Angular Measurements with BIOPAC Goniometers & Torsiometers

CABINA S40 USER MANUAL AUDIOMETRIC TEST BOOTH MU2 REV. 1.05

If you gave any of the following conditions, you must consult your doctor before using your Confidence Vibration Plate Power Plus

SLOW JUICER MODEL: AMR520

Methods of optical measurement for directional light/led-sources and luminaires.

OTAGO LIPOSURG. Compact, powerful system for infiltration and liposuction

Flume Installation Instructions

Convex Array Transducer User Guide. Types 8567-S and 8667

Electric Desk Adjustable

Custom-Made Products / Scientific Research Instruments

Innovative NDT Solutions. Ultrasonic Sensor Technology Phased-Array Search Units. An AREVA and Siemens company

ATyS D10 & D20. Notice d utilisation - Operating instructions AFFICHEURS DÉPORTÉS - REMOTE INTERFACES MAKE YOUR BUSINESS SAFE

V New HGP 20. Standard grippers 7.5. Economical and versatile. Self centring. Choice of gripping action. Standard grippers.

mardtb Goniostat for X-ray crystallography

RLS /M MX SERIES

Xstress 3000 G3/G3R. X-ray Stress Analyzer. Portable X-ray diffractometer specially designed for residual stress and retained austenite measurements

Bruker D8 Discover User Manual (Version: July 2017)

SWITCHGEAR PBD. fuse bases

SWITCHGEAR PBD. fuse bases

DEFORMATION TRANSDUCER CALIBRATOR OPERATION

External Skeletal Fixation (ESF)

AK FIXATOR SYSTEM AK1

A novel method to set up and calibrate goniophotometer

Defining Cutting Edge Quality. Laser Cutting Head BIMO-FSC

Goniophotometer RiGO 801

KA 164F/24/ae/ liquiphant M FTL 50 H- ######## 7 #, FTL 51 H- ######## 7 # Level Limit Switch. Endress+Hauser. The Power of Know How

Original user manual REDCORD AXIS. «Get ready to rotate!» axis_usermanual_may2013_v3 AXIS. Page 1

OWNER S MANUAL and INSTALLATION INSTRUCTIONS

Six Axis Force / Torque Transducer FT Transducer

First Technology Safety Systems. Design Freeze Status. Flex-PLI-GTR Development

ACTIVATED WORKPLACE PORTFOLIO

TR1120 OWNER S MANUAL

RLS /M MX SERIES

Introduction to the Taylor Spatial Frame Hardware. Trademark of Smith & Nephew. Certain marks Reg. US Pat. & TM Off.

OWNER S MANUAL. BODYCRAFT 7699 Green Meadows Dr., Lewis Center, Ohio Tel:

Programmable 1012 Elliptical Cross Trainer (pc) ITEM NO: 1012

Description. Specifications and Ordering Information Proximitor Sensor / interface module/ VDC Housings

Product Guide. NH Fuse System

STANDARD OPERATING PROCEDURE: RIGAKU RU 300 XRD POWDER SAMPLES

Improving Headphone Fit Using Design Of Cable

Technical support: +49 (0)7223 /

aks bed concepts for the day-to-day nursing routine for homecare and in-patient applications

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP

Splitting of the characteristic K-alpha doublet radiation of molybdenum (Item No.: P )

STANDARD 45G GUYED TOWER. includes REV. F & REV. G GENERAL USE FEATURES. Phone (309) Fax (309) The Industry Standard

Installation of force transducers

RJA RJA. Welded cabinet with demountable side panels and back panel, IP 20, loading capacity 600 kg

The Do s and Don ts of Pressure Transducers

Transcription:

RiGO801 Laboratory Requirements 2015-11-25 Air Conditioning According to EN 13032 1 and LM-79-08 the temperature in the environment of the DUT needs to be 25 C +/- 1 C during the measurement. EN 13032-4 requires 25 C +/- 1.2 C for SSL light sources. The air turbulences closed to temperature sensitive illuminants should not exceed 0.2 m/s (EN 13032 1) or 0.25 m/s (EN 13032-4). LM-79-08 just requires a negligible influence of air movement on the light output stability of the DUT. The relative humidity should be below 50%. Darkening All room elements should be painted black with special low reflectivity paint. A black carpet with low reflectivity is recommended for the floor (e.g. Web Point 600, OBJECT CARPET GmbH, http://www.object-carpet.de). Subdivisions, if they are necessary, can be realized with black curtains (e.g. Molton). Lighting Sufficiant room lighting is required for handling the parts at the center of the goniometer as well as in order to align them. During the alignment process using the measuring camera external light is useful, coming from two orthogonal directions. These lights must be mounted above or below the height of the camera at horizontal position. Make sure that the light sources, which are in use, do not cause any back reflexion during the Measurement. To do so darkening baffles, even motorized, or curtains can be used. External Vibrations External Vibrations (e.g. created by production machinery or forklifts etc.) can be harmful to the measurements. The reason for this is the attachment of the goniometer to the floor as well as to the roof. Vibrations at the upper goniometer holder can introduce vibrations to the measuring objects top mount and cause bad conditions for proper measurements. The same influence is given due to vibrations coming from the floor and using the bottom mount mode. Place of the computer workstation and cabling The PC by itself is integrated in the control cabinet. The keyboard, mouse and monitor are placed on an extra table as operator station. Furthermore the control cabinet contains the motor controller and the optional components like power supply and measurement devices. Those devices should be viewable and reachable from the operator station. For the procedure of the measurement setup it is recommended to have visual contact between operator station and goniometer. If it is not possible to have an extra room (e.g. with a window) a curtain should be installed between goniometer and operator station. The distance from the control cabinet to the goniometer is limited by the maximum cable lengths. There are two sets of cables running from the goniometer to the control cabinet. One TechnoTeam Bildverarbeitung GmbH Geschäftsführer: Ust - Id Nr.: DE 150939174 Werner-von-Siemens-Straße 5 Dr. Ing. habil. F. Schmidt Bankverbindung: D-98693 Ilmenau Gesellschaftssitz: Ilmenau Commerzbank Erfurt Sparkasse Arnstadt/Ilmenau Tel. +49 36 77 / 46 24-0 Handelsregister: Jena HRB 300912 Kto. - Nr. 0 802 362 100 Kt.Nr.: 1 113 010 661 Fax. +49 36 77 / 46 24-10 BLZ 820 800 00 BLZ: 840 510 10 http://www.technoteam.de

set comes out of the upper holder of the goniometer (about 50 mm diameter at all). The other one comes out of the base of the goniometer socket (about 40 mm diameter at all). The maximum cable length from the top fixing point to the socket of the switching cabinet is 10m. The bottom cables are not critical (15m). The way of the cables should be discussed with TechnoTeam in advance. The cable laying should be prepared to the installation and is to be done by the customer. Power Supply for the Electronic Enclosure The control cabinet contains the goniometer drive controller, the PC and optional equipment such as power supply units (AC/DC) and measurement devices (e.g. power analyzer). The goniometer drive controller usually operates with a supply of 230V/50Hz fused with 16A but it also works with at least 180 V and a frequency range of 48 to 62 Hz. Transformers can be used inside if the voltage available is too low. Due to a leakage current of more than 3.5mA caused by the servo amplifiers a fault-current circuit breaker with at least 30mA (or none) must be used. The supply cable can be realized as direct cable to a clamp or as a plug connection to an AC outlet. Inside the controller is an emergency stop coupled branch point of the 230V input. From here via a fault-current circuit breaker of 30mA the additional devices are connected, if they are part of the order. Therefore, if the emergency stop is used, those Units will be separated from the input. Optionally those units can be connected to a different circuit. The PC has its own standard power cable. Upper Goniometer Fixing The Goniometer needs a fixed upper mounting point. At this point, a flange is mounted, which goes through a pendulum bearing. The outer goniometer frame rotates around this flange. In order to mount the flange at customer site, TechnoTeam delivers a special upper fixing plate as a simple mechanical interface. The fixing interface to this plate needs to be prepared by the customer. For Installation of the plate please consider the following specifications. Static loads Basically a vertical force is exerted to the upper mounting point. This force is introduced trough the singular weights of the fixing plate, the flange, the top mount object holder and the test object. All fastening elements weigh about 50 kg, the allowed maximum weight is also 50 kg. The overall maximum load is 100 kg. The vertical displacement of the upper fixing point should be less than 0.5 mm at the maximum load. If the balance point of the test object is off-center, an additional torsional moment is introduced. Based on an eccentrically placed mass of 25 kg, with a distance of 600 mm, the resulting torque is 150Nm. This Torque should not have a significant influence to the axis of the Goniometer, i.e. to the axis of the flange. A Torque of 150 Nm should cause a distortion of the upper fastening plane which is less than 0.02. Dynamic Properties The drives of both goniometer axes can generate light vibrations of the outer frame in a range of a few 10 Hz., depending on the driving speed. Those vibrations may cause resonances in the upper fixing construction. Coming from these construction elements the vibrations are then transferred to the test object support rod that may vibrate with an amplitude that influences the stability of the test object. 2/10

To minimize those effects damping elements (rubber buffers) are integrated in the upper flange mounting. In Case it is not possible to attach the upper fixing pate directly to the roof, the appropriate construction should be realized as stable and stiff as possible. To achieve this, over-dimensioning and/or using stiffening bracings is strongly recommended. Conclusion The construction should be sufficient if you consider a maximal deposition of 0.5 mm, at 1000 N and a maximal distortion of 0.02 in any direction, at 150 Nm and use additional over-dimensioning. Upper fixing plate For dimensions of the upper fixing plate (aluminum) see the following drawing. It is not necessary to bring the plate in an exact horizontal position due to the levelling screws that can be used to bring the flange in an exact vertical position. To attach the upper fixing plate to the roof construction the 8 outer wholes are provided. We recommend a steel plate with the same (outer) pattern. In case you prefer a different own solution, please keep a sufficient distance to the inner wholes for the levelling screws. It is also possible to add individual holes to the plate during the installation. Height The bottom of the upper fixing plate (Thickness is 25 mm) must be in a certain height, depending on the model of the goniometer. The Tolerance for this height is +/- 25 mm. Please refer to the drawing for the correct values. 3/10

Distance to the walls The minimal rotation area of the goniometer is defined by the radius of the back side of the camera housing that is nearly the same radius as of the drive mounted at the outer frame. Of course there should be some secure space added to these minimal dimensions. Please refer to the drawings to get the recommended dimensions. To reduce the influence of stray light caused by the side walls a larger distance to the walls is preferable (e.g. 2 or 3 m). Safeguarding The moving goniometer axes results to a risk of injury, which can be reduced by appropriate security measures. The goniometer control unit includes a safety control device (Pilz PNOZ S5) that can be connected to appropriate safety barrier installations (e.g. safety matts, light curtain, door contact). The activation of a safety barrier causes an emergency stop of the axes followed by the deactivation of the servo amplifiers. A risk analysis and planning of additional safety installations is recommended. The following figure shows an example installation. 4/10

RiGO801 1400 5/10

RiGO801 1500 6/10

RiGO801 1800 7/10

RiGO801 2000 8/10

Example constructions Steel profiles to walls and ceiling The following figure shows an example construction based on steel profiles attached to the side walls and the ceiling. The minimum requirement is the stabilization of the upper attachment point along three directions. Thus the steel profile to the right wall can be left because it is over-determined. Portal The following construction has been built in a room that has no stable walls or ceiling. In this case the only solution is to build a portal using steel profiles. Rectangular frame of steel hollow profiles. Inner volume HxWxD: 4080mm x 3560mm x 3560mm (Example construction for RiGO801 2000). A: Vertical steel beam B: Cross-members and stabilizing diagonal elements. Hollow profiles in rectangular shape, longer side vertically oriented. 9/10

C: Framework, quadratic hollow profiles D: Floor fixing plates E: Plate for mounting the upper fixing plate (see above). For the required height please refer to model specific drawings above. All elements have to be dimensioned according to the static and dynamic requirements listed above. All elements must be painted matt black. Fixing to the floor The base of the goniometer is fixed to the basement by standard dowels. The maximum length of the used screws is 80 mm. The holes are drilled by TechnoTeam personnel during the installation. The drilling equipment should be provided by the customer. 10/10