Flow Cytometry Based Exosome Detection and Analysis Using the ZE5 Cell Analyzer

Similar documents
ab Exosome Isolation and Analysis Kit - Flow Cytometry, Cell Culture (CD63 / CD81)

ab Exosome Isolation and Analysis Kit - Flow Cytometry, Cell culture

ab Exosome Isolation and Analysis Kit - Flow Cytometry, Plasma

The first and only fully-automated, multiplexed solution for Measles, Mumps, Rubella and Varicella-zoster virus antibody testing

Concentration Estimation from Flow Cytometry Exosome Data Protocol

TGX and TGX Stain-Free FastCast Acrylamide Kits

BioPlex 2200 Infectious Disease Panels

Gladstone Institutes, University of California (UCSF), San Francisco, USA

Bio-Rad Laboratories. Hemoglobin Testing. VARIANT II Hemoglobin Testing System For HbA 1c

Immunohematology. IH-QC Modular System. Select. Combine. Control.

Bio-Rad Laboratories HEMOGLOBIN Testing Bio-Rad A1c. VARIANT II TURBO Link System. Fully-Automated HbA 1c Testing

Bio-Rad Laboratories HEMOGLOBIN Testing Bio-Rad A1c. VARIANT II TURBO Link. Fully-Automated HbA 1c Testing

Infectious Disease Testing. ULTRA Product Line. Safety is not a Matter of Chance

In vitro human regulatory T cell expansion

In vitro human regulatory T cell expansion

Ordering Information. ProteOn XPR36 System. Protein Interaction Analysis

Cardiac Assessment Controls A critical element of reliable cardiac testing

Cardiac Assessment Controls

In vitro human regulatory T cell suppression assay

FOOD TESTING RAPID'L.Mono Chromogenic Media. Detect Listeria Species in 24 Hours

Annexin V-FITC Apoptosis Detection Kit with SYTOX

Annexin V-FITC Apoptosis Detection Kit

A simple and rapid flow cytometry-based assay to identify a competent embryo prior to embryo transfer.

Infectious Disease Testing. UriSelect 4 Medium. Direct Identification Visibly Reliable

BD CBA on the BD Accuri C6: Bringing Multiplexed Cytokine Detection to the Benchtop

Exosome detection and characterization based on flow cytometry.

LDL Uptake Flow Cytometry Assay Kit

7-AAD/CFSE Cell-Mediated Cytotoxicity Assay Kit

A step-by-step approach to build and analyze a multicolor panel

7-AAD/CFSE Cell-Mediated Cytotoxicity Assay Kit

PRODUCT INFORMATION & MANUAL

MagCapture Exosome Isolation Kit PS Q&A

Third Party Controls for Your Dade Behring Systems

For the rapid, sensitive and accurate measurement of apoptosis in various samples.

PRODUCT INFORMATION. New Reagents for Dako CoverStainer. Choose the H&E staining intensity you want.

RayBio Annexin V-FITC Apoptosis Detection Kit Plus

PosterREPRINT INTRODUCTION. 2-D PAGE of Mouse Liver Samples. 2-D PAGE of E.coli Samples. Digestion / Cleanup. EXPERIMENTAL 1-D PAGE of BSA Samples

Annexin V-PE Apoptosis Detection Kit

Bio-Rad Laboratories. Cardiac Assessment Controls. Value Assigned for Clinical Laboratory and Point of Care Test Systems

RayBio Annexin V-FITC Apoptosis Detection Kit

Dako IT S ABOUT TIME. Interpretation Guide. Agilent Pathology Solutions. ALK, ROS1 and RET IQFISH probes (Dako Omnis) MET IQFISH probe (Dako Omnis)

T H 1, T H 2 and T H 17 polarization of naïve CD4 + mouse T cells

Exo-spin Exosome Purification Kit For cell culture media/urine/saliva and other low-protein biological fluids

ab Membrane fluidity kit Instructions for Use For the detection of membrane fluidity in cells

ApplicationNOTE EXACT MASS MEASUREMENT OF ACTIVE COMPONENTS OF TRADITIONAL HERBAL MEDICINES BY ORTHOGONAL ACCELERATION TIME-OF-FLIGHT.

Bead Based Assays for Cytokine Detection

Instructions. Fuse-It-mRNA easy. Shipping and Storage. Overview. Kit Contents. Specifications. Note: Important Guidelines

Exosomes Immunocapture and Isolation Tools: Immunobeads

Annexin V-Cy3 Apoptosis Detection Reagent

HER2 FISH pharmdx TM Interpretation Guide - Breast Cancer

Providing a Universal, One-step Alternative to Liquid-Liquid Extraction in Bioanalysis

ab Annexin V- mfluor Blue 570 Detection

ab Cell Invasion Assay (Basement Membrane), 24-well, 8 µm

Annexin V-Cy3 Apoptosis Detection Kit

Multi-Parameter Apoptosis Assay Kit

Green Cathepsin B Kit. For Research Use Only

ab Lipid Peroxidation (MDA) Assay kit (Colorimetric/ Fluorometric)

ab Lysosome/Cytotoxicity Dual Staining Kit

ab Pyruvate dehydrogenase (PDH) Enzyme Activity Dipstick Assay Kit

Nature Protocols: doi: /nprot Supplementary Figure 1

Results you can trust

Service and Collaboration

Technical Resources. BD Immunocytometry Systems. FastImmune Intracellular Cytokine Staining Procedures

vol.3 Highlight Product: ExoCap Product Research tools for extracellular vesicles - Exhibition booth at Taiwan on November

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine

Injection Techniques Questionnaire (ITQ) WorldWide Results Needle Gauge

[ Care and Use Manual ]

RayBio Annexin V-Cy5 Apoptosis Detection Kit

Application Information Bulletin: Human NK Cells Phenotypic characterizing of human Natural Killer (NK) cell populations in peripheral blood

Global EHS Resource Center

Bio-Plex Pro Cell Signaling Assays

Improving Food Process Control Using the

Figure S1. PMVs from THP-1 cells expose phosphatidylserine and carry actin. A) Flow

Bio-Rad Laboratories. The Best Protection Whoever You Are. Congenital and Pediatric Disease Testing

artus EBV QS-RGQ Kit Performance Characteristics May 2012 Sample & Assay Technologies Analytical sensitivity plasma

508 the number of suicide deaths in deaths per 100,000 people was the suicide rate in Suicide deaths in 2013 by gender

Supplementary Data 1. Alanine substitutions and position variants of APNCYGNIPL. Applied in

Lipid Droplets Fluorescence Assay Kit

A New Era in SFC Column Technology

Pharmaceutical, Medical and Health-related Government and Regulatory bodies around the world.

Phagocytosis of FITC labelled opsonized and non-opsonized E. coli bacteria by monocytes and granulocytes in a whole blood assay

Chemical compatibility of the Pall QPoint TM Docking Station - Tap Assembly with common surface disinfectants

BEFLEX CUSTOMER SURVEY 2016

Exo-spin Exosome Purification Kit For cell culture media/urine/saliva and other low-protein biological fluids

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Protocol for purification of recombinant protein from 300 ml yeast culture

ab65336 Triglyceride Quantification Assay Kit (Colorimetric/ Fluorometric)

ab HIV-1 Protease Inhibitor Screening Kit (Fluorometric)

Exo-Glow TM Exosome Labeling Kits

XCF TM COMPLETE Exosome and cfdna Isolation Kit (for Serum & Plasma)

MENTAL HEALTH CARE. OECD HCQI Expert meeting 17 th of May, Rie Fujisawa

protein interactions tech

Transcription:

Flow Cytometry ased Exosome Detection and nalysis Using the ZE5 Cell nalyzer Yasha Talaga, Elizabeth Dreskin, Joyce Lee io-rad Laboratories, Inc. 2000 lfred Nobel Drive, Hercules C 94547 Flow Cytometry ulletin 7101 bstract nalysis of small particles such as exosomes can be extremely challenging and frustrating. Electronic noise, voltage adjustment, sheath purification, and population separation are all aspects of exosome detection by flow cytometry that pose significant challenges. However, utilizing the exceptional range of the ZE5 Cell nalyzer alleviates these challenges. Here, we compare flow cytometry based exosome detection methods using the ZE5 and demonstrate that exosomes can be directly detected without being attached to beads. We also highlight further advantages of the ZE5 that lead to experimental reliance. Introduction Exosomes are a type of secreted membrane vesicle of approximately 50 100 nm in diameter. They are mainly involved in intracellular communication but also have key roles in several processes such as metastasis and antigen presentation. Since exosomes are secreted in all major bodily fluids, including blood and urine, and carry important cellular information, they have recently emerged as a novel source of potential biomarkers. However, because of their small size in comparison to cells, they can be difficult to characterize and study. Traditional exosome analysis by flow cytometry requires manual hardware adjustments, advanced instrument calibration, hours of sheath purification, and data manipulation. The ZE5 Cell nalyzer eliminates these hurdles of current exosome research by creating a streamlined process for easier analysis (Figure 1). y using the built-in capabilities of the ZE5, any lab can study exosomes and other small particles. Regardless of the staining method, whether for surface or internal markers, the ZE5 displays optimal sensitivity for small particle identification. Here, we show that surface exosome marker proteins such as CD63 and CD81, as well as intravesicular markers LIX and TSG101 can easily be detected using the ZE5 Cell nalyzer. The ZE5 has many unique features that, in addition to studying large cancer cells, allow it to be used in small particle analysis. Methods and Results Sample Preparation MCF-7 cells were cultured in minimum essential media (MEM) supplemented with 10% FS and 0.01 mg/ml insulin until they were 70 80% confluent. The cells were washed twice with PS and incubated with exosome-free media for 12 72 hr. The media was collected and filtered through a 0.22 µm membrane to remove cells and debris. The filtered media was mixed thoroughly with 0.5 volumes of Total Exosome Isolation Reagent (Life Technologies). The mixture was incubated at 4 C overnight followed by centrifugation at 10,000 x g for 1 hr at 4 C. The supernatant was aspirated, and the pellet was washed with PS filtered through a 0.1 µm membrane. The protein concentration and size of the exosomes were determined by the NanoDrop Spectrophotometer (Thermo Scientific Inc.) and Zetasizer Nano ZSP Dedicated Zeta nalyzer (Malvern Pananalytical) as 185 300 nm. Culture your cells Stain with markers nalyze with the ZE5 Visualize with data analysis software Fig. 1. Exosome detection workflow with the ZE5 Cell nalyzer

Flow Cytometry-ased Exosome Detection and nalysis Using the ZE5 Cell nalyzer Instrument Setup ProFlow Sort Grade Water (io-rad Laboratories) was used to analyze samples on the ZE5 Cell nalyzer (io-rad Laboratories). QC was performed using ZE Series QC eads (io-rad Laboratories). mixture of yellow fluorescent size beads ranging from 0.22 1.35 µm (Spherotech) was used to set up instrument voltages and thresholds (Figure 2). For small particle setup, single or dual thresholds can be used to set up the instrument. For direct exosome detection of surface markers, forward side scatter (FSC) from the 405 nm laser and fluorescent signal were used as thresholds. FSC from the 405 nm laser was used to set up the threshold for intravesicular marker and bead-based exosome detection. 5 Laser-27 Colors 355 nm- 5 Colors 405 nm- 7 Colors with SPD 488 nm- 4 Colors 561 nm- 7 Colors 640 nm - 4 Colors I I I I I 0.01 0.1 1 10 100 C D E 10 5 10 4 1.35 μm SSC 488/10-rea Log 10 3 10 2 10 1 0.22 μm 0.45 μm 0.88 μm 10 0 FSC 405/10 (spd)-rea Log Fig. 2. Instrument setup., the ZE5 is equipped with extremely low-noise electronics and offers a small particle photomultiplier tube (PMT) detector using the 405 nm laser, which allows for more color combinations., the ZE5 lets users choose to either do a single threshold gating or C, exclude more debris and electronic noise using a dual-parameter threshold. D, the ZE5 sheath fluid is DI water, which allows the user to source their sheath. The system also carries an inline filter to aid with small particle analysis. E, using 0.22 µm beads, dual-threshold triggers were set on forward side scatter (FSC) from the small particle detector (SPD) on the 405 nm laser and the FL1 channel (C). Yellow size beads (0.22 1.35 µm) were used to set the voltages. 2018 io-rad Laboratories, Inc. 2 ulletin 7101

Non-ead ased Surface Staining of Exosomes ll buffers used for exosome detection were filtered through a 0.1 µm membrane. The titrated amount of fluorochrome-labeled antibody was used for surface and intravesicular staining. For exosome surface staining, 2 µg of exosomes were added to 50 µl of PE buffer (PS, 5 mm EDT, and 0.5% S) incubated with FITC anti-human CD63 (io-rad Laboratories) and PC anti-human CD81 (iolegend) for 30 min at room temperature. fter incubation, the samples were washed with PE and re-suspended in 500 µl of PE. Exosome samples were filtered through a 10 µm filter prior to loading on the instrument. s shown in Figure 3, exosome surface markers were easily detected compared to an unstained control. 10 5 10 5 10 4 10 4 SSC 488/10-rea Log 10 3 10 2 R1 CD81-PC-rea Log 10 3 10 2 10 1 Exosomes 10 1 C 10 0 10 5 FSC 405/10 (spd)-rea Log D 10 0 10 5 CD63-FITC-rea Log 10 4 10 4 CD81-PC-rea Log 10 3 10 2 CD81-PC-rea Log 10 3 10 2 10 1 10 1 E CD63-FITC-rea Log 10 0 10 5 10 0 CD63-FITC-rea Log 10 4 CD81-PC-rea Log 10 3 10 2 10 1 10 0 CD63-FITC-rea Log Fig. 3. Purified exosomes., using the instrument setup from Figure 2, purified exosomes were detected by gating on FSC from the 405 nm laser with the SPD and on side scatter (SSC) from the 488 nm laser on an area log scale., an unstained control was used to set the quadrant gating for CD63-FITC vs. CD81-PC. Single-color control staining for C, CD63 and D, CD81 were then collected followed by E, a dual-stained sample. 2018 io-rad Laboratories, Inc. 3 ulletin 7101

Flow Cytometry-ased Exosome Detection and nalysis Using the ZE5 Cell nalyzer Intravesicular Staining The Intracellular Fixation and Permeabilization uffer Set (eioscience) was used to fix and permeabilize exosomes for intravesicular staining. Exosomes (2 µg) were fixed in 100 µl of IC Fixation uffer and incubated in the dark at room temperature for 20 min. fter incubation, the samples were washed twice with 1 ml of permeabilization buffer and then resuspended in 100 µl of the same buffer. The samples were then incubated with PE anti-human TSG101 (bcam) and anti-human LIX conjugated to 494/516 excitation/emission labeling dye, using the ReadiLink ntibody Labeling Kit (io-rad Laboratories), for 30 min at room temperature. fter incubation, the samples were washed twice with 1 ml of permeabilization buffer and resuspended in 500 µl of PE buffer (Figure 4). 1.0K 1.2K 800 900 Count 600 Count 600 400 300 200 0 I I I I I 10 5 10 6 10 7 10 8 FL03- : : LIX-Readilink FITC- 0 I I I I I 10 5 10 6 10 7 10 8 FL11- : : TSG101-PE- Fig. 4. Exosome intravesicular detection. The marker proteins LIX and TSG101 are used to define exosome populations and are detectable by flow cytometry. Overlay histograms for, LIX and, TSG101 are shown in red and the unstained control in green. 2018 io-rad Laboratories, Inc. 4 ulletin 7101

Flow Cytometry-ased Exosome Detection and nalysis Using the ZE5 Cell nalyzer Traditional ead-ased Exosome Detection nti-human CD63 antibody (10 µg, io-rad Laboratories) was incubated with 100 µl of Sureeads Protein G Magnetic eads (io-rad Laboratories) with rotation for 10 min at room temperature. Coated Sureeads were then incubated with 10 µg of exosomes for 1 hr at room temperature. Exosome-coated Sureeads were washed three times with PS containing 0.1% Tween 20, and resuspended in 250 µl of PE-0.1% Tween 20 (PS, 5 mm EDT, 0.5% S, and 0.1% Tween 20). Exosome-coated Sureeads (50 µl) were incubated with FITC anti-human CD63 (io-rad Laboratories) and PC anti-human CD81 (iolegend) for 30 min at room temperature and washed twice with PE-0.1% Tween 20. Figure 5 shows successful characterization of exosome surface markers using bead-based flow cytometry on the ZE5 Cell nalyzer. 10 5 10 5 SSC 488/10-rea Log 10 4 10 3 10 2 R1 CD81-PC-rea Log (comp) 10 4 10 3 10 2 10 1 10 1 10 0 FSC 405/10-rea Log CD63-FITC-rea Log (comp) 10 0 C 10 5 D 10 5 10 4 10 4 CD81-PC-rea Log (comp) 10 3 10 2 CD81-PC-rea Log (comp) 10 3 10 2 10 1 10 1 CD63-FITC-rea Log (comp) 10 0 CD63-FITC-rea Log (comp) 10 0 E. 10 5 10 4 CD81-PC-rea Log (comp) 10 3 10 2 10 1 CD63-FITC-rea Log (comp) 10 0 Fig. 5. ead-based exosome capture. Sureeads Protein G Magnetic eads are 2.4 3.4 µm. Traditional flow cytometry methods use bead capture to analyze exosomes since they are difficult to detect on most cytometers., to demonstrate that bead-based detection is achievable on the ZE5 Cell nalyzer and comparable to direct detection, Sureeads Protein G Magnetic eads were coated with unlabeled CD63 and detected in FSC from the 405 nm laser and SSC from the 488 nm laser., an unstained control was used to set the quadrant gating for exosome markers. Single-color controls for C, CD63 and D, CD81 were collected. E, Sureead bead-coated exosomes were stained for both CD63 and CD81. 2018 io-rad Laboratories, Inc. 5 ulletin 7101

Flow Cytometry-ased Exosome Detection and nalysis Using the ZE5 Cell nalyzer Conclusions The direct detection of exosomes is possible on the ZE5 Cell nalyzer Traditional bead detection methods for flow cytometry can also be performed on the ZE5 Distinct intravesicular exosome marker proteins such as LIX and TSG101 can be quantified on the ZE5 The exosome workflow is made simpler by eliminating preparation steps on the ZE5 dvantages of Using the ZE5 Cell nalyzer Exosome research can be challenging, from sheath purification to gating in data analysis. To address these challenges in an easy-to-use system, the ZE5 was designed with the input of flow cytometry researchers. s a result, it contains built-in capabilities that allow any lab to study exosomes and other small particles. The ZE5 is equipped with extremely low noise electronics and offers a small particle PMT detector using a 100 mw 405 nm laser. Together, this aspect, coupled with dual parameter thresholding, solves the problem of distinguishing exosomes or other small particles from debris and noise. Furthermore, the ZE5 uses DI water as its sheath and has an inline sheath filter to eliminate the need to pre-filter. This, together with filtering of samples leaves few other cellular particulates to populate the plots. This boosts confidence in gating on the exosome population. lthough io-rad offers bead conjugation methods, the ZE5 Cell nalyzer is able to detect exosomes without beads. Using size beads, the ZE5 can quickly be set up to easily collect purified exosomes. Visit bio-rad.com/exosome-appnote for more information. io-rad is a trademark of io-rad Laboratories, Inc. in certain jurisdictions. ll trademarks used herein are the property of their respective owner. io-rad Laboratories, Inc. Life Science Group Web site bio-rad.com US 1 800 424 6723 ustralia 61 2 9914 2800 ustria 43 01 877 89019 elgium 32 03 710 53 00 razil 55 11 3065 7550 Canada 1 905 364 3435 China 86 21 6169 8500 Czech Republic 36 01 459 6192 Denmark 45 04 452 10 00 Finland 35 08 980 422 00 France 33 01 479 593 00 Germany 49 089 3188 4393 Hong Kong 852 2789 3300 Hungary 36 01 459 6190 India 91 124 4029300 Israel 972 03 963 6050 Italy 39 02 49486600 Japan 81 3 6361 7000 Korea 82 2 3473 4460 Mexico 52 555 488 7670 The Netherlands 31 0 318 540 666 New Zealand 64 9 415 2280 Norway 47 0 233 841 30 Poland 36 01 459 6191 Portugal 351 21 4727717 Russia 7 495 721 14 04 Singapore 65 6415 3188 South frica 36 01 459 6193 Spain 34 091 49 06 580 Sweden 46 08 555 127 00 Switzerland 41 0617 17 9555 Taiwan 886 2 2578 7189 Thailand 66 2 651 8311 United rab Emirates 971 4 8187300 United Kingdom 44 01923 47 1301 ulletin 7101 Ver US/EG 18-0422 0618 Sig 0118