Minimally Invasive Percutaneous Plate Osteosynthesis Does Not Increase Complication Rates in Extra-Articular Distal Tibial Fractures

Similar documents
A study of functional outcome of distal tibial extraarticular fracture fixed with locking compression plate using MIPPO technique

Minimally invasive plate osteosynthesis for distal tibial fractures

Advantage and limitations of a minimally-invasive approach and early weight bearing in the treatment of tibial shaft fractures with locking plates

Percutaneous Screw Fixation of Distal Tibia Fractures Functional Results in Sixteen Patients

A study of MIPO by locking compression plate fixation in the management of distal tibial metaphyseal fractures

Minimally invasive osteosynthesis of adult tibia fractures by means of rigid fixation with anatomic locked plates

Techique. Results. Discussion. Materials & Methods. Vol. 2 - Year 1 - December 2005

Minimally invasive percutaneous plate fixation of distal tibia fractures

Minimally Invasive Plating of Fractures:

Distal femoral fracture with subsequent ipsilateral proximal femoral fracture

Outcome of the Treatment of Distal Tibia Fractures by Minimal Invasive Locked Plate A Short Term Study

Minimally Invasive Plate Osteosynthesis (MIPO) for Proximal and Distal Fractures of The Tibia: A Biological Approach

ROTATIONAL PILON FRACTURES

Distal Femur Fractures in The Elderly The Ideal Construct

Minimally Invasive Osteosynthesis of Distal Tibia Fractures using Anterolateral Locking Plate

BRIDGE PLATING OF COMMINUTED SHAFT OF FEMUR FRACTURES

Fractures of the tibia shaft treated with locked intramedullary nail Retrospective clinical and radiographic assesment

Plate Fixation Options

Treatment of Diaphysio-Metaphyseal Fracture of Tibia by Intramedullary Nail in Combination with Poller Screw

AO / Synthes Proximal Posterior Medial Tibia Plate. Tibial Plateau Fx. Osteosynthesis

LISS DF and LISS PLT. Less Invasive Stabilization Systems for Distal Femur and Proximal Lateral Tibia.

Vasu Pai FRACS, MCh, MS, Nat Board Ortho Surgeon Gisborne

Correction of Traumatic Ankle Valgus and Procurvatum using the Taylor Spatial Frame: A Case Report

Osteosynthesis involving a joint Thomas P Rüedi

Tibial Shaft Fractures

A comparative study of locking plate by MIPO versus closed interlocking intramedullary nail in extraarticular distal tibia fractures

Early results with the new internal fixator systems LCP and LISS : A prospective study

Medico Research Chronicles

EVOS MINI with IM Nailing

International Journal of Health Sciences and Research ISSN:

FUNCTIONAL OUTCOME OF PROXIMAL TIBIA EXTR-ARTICULAR FRACTURES TREATED WITH LOCKING COMPRESSION PLATING

Plate vs Nail for Distal Tibia Fxs

Surgery-Ortho. Fractures of the tibia and fibula. Management. Treatment of low energy fractures. Fifth stage. Lec-6 د.

Tibia fractures are the third most common long bone

Original Research Article

CASE REPORT. Bone transport utilizing the PRECICE Intramedullary Nail for an infected nonunion in the distal femur

Intramedullary Nailing of Proximal Quarter Tibial Fractures

International Journal of Health Sciences and Research ISSN:

MINIMALLY INVASIVE PLATE OSTEOSYNTHESIS FOR DISTAL RADIUS FRACTURES: SURGICAL TECHNIQUE M. TOBE 1, K. MIZUTANI 1, Y. TSUBUKU 1, Y.

Minimally invasive locking screw plate fixation of non-articular proximal and distal tibia fractures

Outcome of minimally invasive plate osteosynthesis (MIPO) technique in distal tibial fracture

LESS INVASIVE STABILIZATION SYSTEM (LISS) IN THE TREATMENT OF DISTAL FEMUR FRACTURES

Intramedullary fibular fixation in the operative management of fractures of the distal tibia and fibula

Role of tibia interlocking nail in treating distal tibial metadiaphyseal fractures: study of 46 cases

Diaphyseal Humerus Fractures. OTA Course Dallas, TX 1/20/17 Ellen Fitzpatrick MD

Section: Orthopaedics. Original Article INTRODUCTION

Pediatric Tibia Fractures Key Points. Christopher Iobst, MD

Locked Plating: Clinical Indications

A Clinical Study For Evaluation Of Results Of Closed Interlocking Nailing Of Fractures Of The Shaft Of The Tibia

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plate Aiming Instruments. Part of the 3.5 mm LCP Percutaneous Instrument System.

Original Research Paper

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system.

Factors affecting fracture healing after intramedullary nailing of the tibial diaphysis for closed and grade I open fractures

Segmental tibial fractures treated with unreamed interlocking nail A prospective study

Orthopedics in Motion Tristan Hartzell, MD January 27, 2016

Minimally Invasive Plate Osteosynthesis Using a Screw Compression Method for Treatment of Humeral Shaft Fractures

Fracture Classification

Minimally Invasive Plate Osteosynthesis (MIPO) for Multifragmentary Fractures of the Proximal Tibia in 20 Patients in Rangpur Medical College Hospital

Study of Ender s Nailing in Paediatric Tibial Shaft Fractures

Minimally Invasive Surgery by Angular Stability Systems in Proximal Tibia Fractures Biomechanical Characteristics and Preliminary Results

A clinical study of minimal invasive anterior bridge plating for humerus shaft fractures

Pilon Fractures Pearls of Treatment Steven Steinlauf, MD The Orthopaedic Foot and Ankle Institute of South Florida CSOT November 2017, Tampa

Periarticular Fractures of the Knee in Polytrauma Patients

OUTCOME OF MANAGEMENT OF CLOSED PROXIMAL TIBIA FRACTURES IN TERTIARY HOSPITAL OF SURAT Karan Mehta 1, Prashanth G 2, Shiblee Siddiqui 3

LCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability.

A comparative study of less invasive stabilization system and titanium elastic nailing for subtrochanteric femur fractures in older children

Use of Unlocked Intramedullary Nailing in Winquist Type I and II Femoral Isthmus Fracture

LCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability.

Surgical Technique. Fibula Rod System

Treatment of malunited fractures of the ankle

LCP Anterior Ankle Arthrodesis Plates. Part of the Synthes Locking Compression Plate (LCP) System.

Technique Guide. LCP Proximal Femoral Hook Plate 4.5/5.0. Part of the LCP Periarticular Plating System.

PediLoc 3.5mm and 4.5mm Contour Femur Plate Surgical Technique

One Stage Treatment of Open Proximal Tibia Fractures by Minimally Invasive Technique Using Locked Plate

A Clinical Study For Management Of Tibial Diaphyseal Fractures In Adults With Locking Compression Plate Using Mippo Technique

Intramedullary Nail Fixation of the Fibula as a Treatment Alternative of Ankle Fractures in a High Risk Patient Population

Outcome of extra articular distal Shaft of tibia fracture treated by reamed interlock nail

2.2 Diaphyseal fractures: principles

Intramedullary nailing without interlocking screws for femoral and tibial shaft fractures

Locking Plate in Proximal Tibial Fracture: A Correlation between the Coronal Alignment of Tibia and Joint Screw Angle

Tibial plateau fractures: four years review at B&B Hospital

Locked Plating: Biomechanics and Biology

Locked plating constructs are creating a challenge for surgeons.

Primary internal fixation of fractures of both bones forearm by intramedullary nailing

Study on the Functional Outcome of Internal Fixation in Tibial Plateau Fractures

Technique Guide. 2.7 mm/3.5 mm LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system.

Minimally Invasive Plate Osteosynthesis with Locking Compression Plate for Distal Diametaphyseal Tibia Fracture

FUNCTIONAL OUTCOME OF MINIMALLY INVASIVE PLATE OSTEOSYNTHESIS OF PROXIMAL TIBIAL FRACTURES USING LOCKING COMPRESSION PLATES

Minimally invasive plate osteosynthesis (MIPO) of the humeral shaft fracture Is it possible? A cadaveric study and preliminary report

Principles of intramedullary nailing. Management for ORP

7/23/2018 DESCRIBING THE FRACTURE. Pattern Open vs closed Location BASIC PRINCIPLES OF FRACTURE MANAGEMENT. Anjan R. Shah MD July 21, 2018.

AOFAS Resident Review Course September 28, Justin Greisberg, MD Associate Professor of Orthopaedic Surgery Columbia University

COMPARATIVE STUDY OF MANAGEMENT OF DIAPHYSEAL FEMUR FRACTURE WITH INTRAMEDULLARY INTERLOCKING NAIL AND K. NAIL

A prospective study of treatment of distal femur fractures with locking condylar plate

PediLoc 3.5mm and 4.5mm Bowed Femur Plate Surgical Technique

JMSCR Vol 3 Issue 9 Page September 2015

Technique Guide. TomoFix Osteotomy System. A comprehensive plating system for stable fixation of osteotomies around the knee.

The pilon tibiale fracture

Tibial deformity correction by Ilizarov method

Transcription:

Send Orders for Reprints to reprints@benthamscience.ae The Open Orthopaedics Journal, 2015, 9, 73-77 73 Open Access Minimally Invasive Percutaneous Plate Osteosynthesis Does Not Increase Complication Rates in Extra-Articular Distal Tibial Fractures Izzet Bingol 1, Nadir Yalcin *,1, Vedat Bicici 1, Tolga Tulunay 2, Kaan Yuksel 1 and Kasim Kilicarslan 1 1 Department of Orthopaedics and Traumatology, Ataturk Training and Research Hospital, Ankara, Turkey 2 Yenimahalle State Hospital, Ankara, Turkey Abstract: Background: Selection of a treatment method in cases of unstable, nonarticular distal tibial fractures is still a matter of discussion. Intramedullary nailing, which is a gold standard for tibial shaft fractures, does not always work for this specific transition area between diaphysis and metaphysis. Instead, new minimally invasive techniques with special implants are popular. Aims: To determine the functional and radiological results of distal tibial fractures treated with minimally invasive percutaneous plate osteosynthesis (MIPPO) technique. Study Design: Retrospective cohort analysis. Methods: Thirty distal tibial fractures treated with MIPPO method, between January 2006 and December 2010, were evaluated retrospectively. All patients were classified according to AO/OTA classification. Period of hospital stay, time of fracture union, time to allow full weight bearing, early and late complications were inquired. Functional outcomes were assessed by AOFAS scores. Results: There were 13 male and 17 female patients with an average age of 44.26 (range, 22-77 years). One superficial infection and one malunion were observed. Two patients were revised for the loss of reduction and healed uneventfully. According to the AO/OTA classification, 23 patients were 43-A1 (76.6%), 3 were 43-A2 (10%) and 4 were 43-A3 (13.3%). Post-operative mean stay of patients at the hospital was 2.6 ± 1.42 days (range, 1-7 days). Mean full weightbearing period of the patients was found out as 13.16 ± 2.6 weeks (range, 10-22 weeks). The mean period of union of fracture for patients was found out as 19.8 ± 2.99 weeks (range, 16-34 weeks). Conclusion: Treatment of distal tibial fractures with MIPPO method provides a successful treatment strategy as long as used as per the technique, and it respects and does not harm soft tissues which allows early callus formation and rapid healing that enable the patient to walk as early as possible after the operation. The overall clinical and functional outcome is still good despite minor complications. Keywords: Minimal invasive surgery, tibial fractures, treatment outcome. INTRODUCTION Selection of a treatment in cases of unstable distal tibial fractures that do not extend over the joint is still a matter of discussion [1, 2]. Various treatment methods such as external fixation, intramedullary (IM) nailing and plate osteosynthesis are described for distal tibial fractures [2-4]. Locked IM nailing is accepted as golden standard in tibial shaft fractures [1, 3]. However, there are concerns about using IM nailing in the distal tibia including the difficulty of fixation of nail in the tibia because of the dimensional change in between the diaphysis and the metaphysis and the risk to advance to the ankle [2]. As a result of open reduction and internal fixation with wide soft tissue dissection and potential periosteal injury, there may be high infection rate, delayed union and non- *Address correspondence to this author at the Cukurambar Mah. 1476. Sok 20/18, Cankaya 06520 Ankara, Turkey; Tel: +90 533 230 8851; Fax: +90 312 291 2705; E-mail: drmnyalcin@yahoo.com union [1, 4]. Recently, minimally invasive percutaneous plate osteosynthesis (MIPPO), applied by indirect reduction has been a successful treatment method in cases of lower extremity complex fractures [5, 6]. The studies suggest that hematoma loss has negative effect on bone healing [7]. The real goal with MIPPO is to protect osteogenic hematoma in the fractured region and the arterial nutrition in the bone from iatrogenic soft tissue damage [8]. Vascular injection studies have shown that MIPPO technique preserves periosteal circulation in the highest level when compared with classical open technique [8, 9]. With the increase in findings which indicate the significance of biological factors in bone healing, the practice of opening the fracture line by means of anatomical reduction and stable fixation and cleaning the hematoma and then freely stabilizing fractured fragments shifted to the practice of protecting fracture hematoma [10-12]. Locking compression plating (LCP) provides angular stability for fixation of fractures [13]. The anatomical shape of the plate prevents malalignment of the fracture, and 1874-3250/15 2015 Bentham Open

74 The Open Orthopaedics Journal, 2015, Volume 9 Bingol et al. provides right angular and axial weight distribution [8]. Locked screws prevent the plate from applying pressure on the bone and do not harm periosteal circulation [5]. The goal with the implants used is to obtain an easy fracture union without disrupting the biological structure. Our goal with this study is to evaluate the results of our patients with extra articular distal tibial fractures whom we treated using MIPPO technique with LCP plate, in terms of functional and radiological results, period of stay in the hospital, period of union, period of bearing weight and the complications. MATERIALS AND METHODS Thirty distal tibial fractures of 30 patients treated with MIPPO method between January 2006 and December 2010 were evaluated retrospectively. Post-operative early and late complications such as deep or superficial infections, delayed union, nonunion, malunion, implant failure, period of hospital stay and time of fracture union were inquired (Table 1). Table 1. The distribution of the cohort in terms of gender, age and AO/OTA classification. n tubular plate in order to adjust length and alignment. Anatomic LCP plate or precontoured flat metaphyseal LCP plate of 3.5-4.5 mm has been applied from a small incision over the medial malleolus, well away from the fracture line. The plate was temporarily fixed by means of a K wire on its proximal and distal point, and its compatibility with the bone was checked under fluoroscopy in AP and lateral plan. Afterwards, the plate was taken closer to the bone by means of one cortical screw. At least 3 locking screws passing through both cortices were applied on each fracture fragment according to the bone quality. After the operation, all patients were routinely followed by elevation, cold and bandage application on the extremity. Antibiotic prophylaxis with first generation cephalosporin was applied to all. As of day one, the patients started passive and active knee and ankle exercises. They were mobilized by means of double crutches stepping on the intact extremity. The patients were evaluated at the second week, first, third, sixth months and a year after the operation for both clinical and radiological control. During clinical examination, any wound problem, deformity, ankle and knee range of motion and patients compliance to the rehabilitation protocol were observed. With bidirectional radiographic examination, callus formation was inquired [16]. According to callus formation, full weight bearing was started (Fig. 1). Functional outcomes were assessed by AOFAS scores. Gender Male Female Age AO/OTA Classification 43-A1 43-A2 43-A3 17 13 44.26 (22-77 years) 23 (76.6%) 3 (10%) 4 (13.3%) Statistical Analysis Collected data were analyzed in SPSS for Windows 11.5 package program. Mean and standard deviations were calculated for numerical variables while frequency and percentage were calculated for categorical variables. Informed consent was obtained from each patient. RESULTS Fractures extending to the ankle joint, pediatric fractures, stress fractures and pathologic fractures were excluded. All fractures were reduced closely and stabilised with a plaster splint immediately after admission in emergency service. The patients with severe soft tissue injury and oedema were treated with elevation and cold application till soft tissue was healed and the oedema disappeared. All patients were classified according to AO/OTA classification [14]. Surgical Technique The patient was laid down supine on the operation table. A pillow was placed under the buttock. Manual traction under fluoroscopy was applied for indirect reduction of the fracture and the alignment was obtained. The reduction was checked with fluoroscopy to achieve reduction compatible with the criteria of Kretek et al. [15]: rotation less than 10 o, cortical contact more than 50%, shortening less than 10 mm, angulation less than 5 o coronal and 10 o in sagittal plane. All patients with lateral malleolar fractures and fibular shaft fractures along with shortening were operated with 1/3 There were13 male and 17 female patients with an average age of 44.26 (range, 22-77 years). According to the AO/OTA classification, 23 patients were 43-A1 (76.6%), 3 were 43-A2 (10%) and 4 were 43-A3 (13.3%). According to the Gustillo-Anderson classification, 2 patients (6.6%) had type 1 open fracture (Table 1). We performed operation on 17 of the patients (56%) in the first 24 hours while we operated 10 of them (33%) in the first 72 hours. Seven of the patients with lateral malleolus fractures were treated by open reduction and internal fixation with 1/3 tubular plate. 11 of the patients having minimally displaced fibula shaft fracture were followed by conservative treatment. One of the patients had medial malleolus fracture, and it was fixed by open reduction and internal fixation. Post-operative mean stay of patients at the hospital was 2.6 ± 1.42 days. Mean total period of stay at the hospital was 4.6 ± 1.95 days. Mean follow-up period of the patients was 14.46 ± 3.73 months. Mean full weight-bearing period of the patients we followed up, was found as 13.16 ± 2.6 weeks. The mean period of union of fracture for patients was found as 19.8 ± 2.99 weeks. The mean AOFAS score was 88.3±10.8 (range, 54-98). There were 18 (60%) excellent, 7 (23.3%) good, 3 (10%) fair and 2 (6.7%) bad results (Table 2).

MIPPO Technique in Distal Tibial Fractures The Open Orthopaedics Journal, 2015, Volume 9 75 (A) Table 2. The follow-up period, postoperative stay, total period of stay, full weight bearing, union periods and AOFAS scores of the patients. Mean ± SD Follow-up period 14.46 months ± 3.73 months Post-operative stay at the hospital 2.6 days ± 1.42 days Total period of stay at the hospital 4.6 days ± 1.95 days Full weight-bearing period 13.16 weeks ± 2.6 weeks Period of union of fracture 19.8 weeks ± 2.99 weeks AOFAS Score 88.3 ± 10.8 (B) (C) (D) Fig. (1). (A, B) Anteroposterior and lateral radiograph of a 34 years old male patient having distal tibial fracture. (C, D) Anteroposterior and lateral radiograph of the same patient at postoperative 2 nd month. In terms of complications, one of our patients developed superficial infection, resolved with antibiotherapy and debridement. We did not experience any deep infection or osteomyelitis. During follow up, we observed angulation in sagittal plane in one and in coronal plane in two patients. Sagittal plane angulation was 10 degrees and followed conservatively and healed without any problem. Two coronal plane (valgus) angulations were revised (one with again a LCP plate at fourth month and the other with an intramedullary nail at third month). They both healed well after revision. DISCUSSION Diaphyseal-metaphyseal bone region is under risk in terms of periosteal blood flow. MIPPO technique preserves the hematoma in the fractured area while at the same time it prevents iatrogenic soft tissue injury and additional osseousvascular damage that happens in open surgery [17, 18]. Large surgical exposures, which are required for absolute fixation, gave way to the minimally invasive techniques in which aligning two adjacent joints of long bones anatomically or nearly anatomic position without any rotation is generally sufficient. The method employed involves using plates and screws internally in a similar way to the principles of external fixator. Among its most important advantages is that it gives minimal damage to the periosteum due to minimal contact with the bone. Currently, sufficient stability for early functional treatment and sufficient instability for speeding up the healing have begun to be the essential principles of fracture healing [11]. Therefore, we aimed to analyse the results of distal tibial nonarticular fractures treated in line with these principles, with MIPPO technique, on this particular area of tibial bone where alternative techniques are still debateful. We inquired whether this technique is efficient in both clinically and functionally. We also explored whether this technique, by considering the biology of fracture healing excessively, provides early healing and union with early functional improvement. Our results suggest that, although this fracture type is prone to early and late complications naturally, MIPPO is simple, reliable and effective if applied according to the rules of the technique. There are some limitations of our study. First is the retrospective nature of the study. Another limitation is the lack of a control group that we may compare the results.

76 The Open Orthopaedics Journal, 2015, Volume 9 Bingol et al. In case series, positive results have been published with regard to infection and nonunion rates with MIPPO technique [1, 19]. In contrast, Lau et al. reported 7 cases of late infections among 48 patients (15%) that were operated with MIPPO technique, during a 3-year follow up [20]. They concluded that MIPPO fixation of distal tibial fractures is safe and efficient although complications such as late wound infection and skin impingement by the implant are relatively common. We had only one patient who developed superficial infection, and that patient was healed with antibiotherapy without a necessity for surgical intervention. Borg et al. [21] reported surgical technique and results of a series of 21 patients. They reported that 14 patients had fracture reduction being anatomic or close to anatomic without angulation. They reoperated 2 patients due to malreduction. In early post-operative period, we have observed anatomic or close anatomical reduction except 1 patient who had 10 o angulation to anterior. The patient did not accept a revision and the fracture healed uneventfully. Unlike the case with absolute fixation, biological techniques call for alignment in the manner of bridging without applying compression to the fracture line. In that way, relative fixation is obtained. Such fixation is elastic. Micromotion occurs in the fracture line, and stability begins to develop along with the formation of callus [11]. Callus that is formed within biological system falls within secondary callus formation unlike absolute fixation. Medullar and periosteal callus provides healing in such bones [22, 23]. Number of the screws to be used as per platescrew intensity must be 0.4 to 0.5 times lesser than the number of all holes of the plate. Filling all holes and putting the screws too close to the fracture line will cause stress intensity, and elastic fixation will be disrupted [24]. Abiding by these rules, we observed 18 o of valgus angulation in one of our patients at the 3 rd month follow-up, who was revised with tibial intramedullary nail; 20 o of valgus angulation in the other at 4 th month, who was revised again by MIPPO, also. We experienced that these losses of fixation were due to stress intensity. We believe that surgical technique has great significance in MIPPO, sustainability of fixation system and healing of fracture as a result. In a study carried out by Redfern et al. [1], 20 patients with unstable, closed distal tibial fractures were operated with MIPPO. They suggested partial weight bearing (10-15 kg) in the post-operative first day without a need for plaster cast. They reported that average full weight-bearing period is 12 weeks (range, 8-20 weeks), and average union period is 23 weeks (range, 18-29). We allowed our patients to bear weight as early as tolerated, and we did not face any implant failure due to early weight bearing. We found that average full weight-bearing period of our patients is 13.16 weeks (range, 10-22 weeks) and average union period is 19.8 weeks (range, 18-34 weeks), which are similar with the literature [19, 25, 26]. CONCLUSION We have obtained quite satisfactory results with MIPPO for the distal diaphyseal-metaphyseal tibial fractures. Considering other methods that can be used for the same areas, we have not come across with major complications that may affect the result. MIPPO method provides a successful treatment strategy as long as used as per the technique, and it respects and does not harm soft tissues in cases of distal tibial fractures. It also enables early mobilization and rehabilitation without any external support. The overall clinical and functional outcome is still good despite minor complications. CONFLICT OF INTEREST There is no conflict of interest in connection with this paper. There was no financial contribution to the work being reported. ACKNOWLEDGEMENTS Declared none. REFERENCES [1] Redfern DJ, Syed SU, Davies SJ. Fractures of the distal tibia: minimally invasive plate osteosynthesis. Injury 2004; 35: 615-20. [2] Zelle BA, Bhandari M, Espiritu M, Koval KJ, Zlowodzki M. Treatment of distal tibia fractures without articular involvement: a systematic review of 1125 fractures. J Orthop Trauma 2006; 20: 76-9. [3] Adam P, Bonnomet F, Ehlinger M. Advantage and limitations of a minimally-invasive approach and early weight bearing in the treatment of tibial shaft fractures with locking plates. Orthop Traumatol Surg Res 2012; 98: 564-9. [4] Tornetta P 3rd, Weiner L, Bergman M, et al. Pilon fractures: treatment with combined internal and external fixation. J Orthop Trauma 1993; 7: 489-96. [5] Field JR, Hearn TC, Caldwell CB. Bone plate fixation: an evaluation of interface contact area and force of the dynamic compression plate (DCP) and the limited contact-dynamic compression plate (LC-DCP) applied to cadaveric bone. J Orthop Trauma 1997; 11: 368-73. [6] Frigg R. Development of the locking compression plate. Injury 2003; (34): 6-10. [7] Balkar F, Duygulu F. Kırık iyileşmesinde kırık hematomunun önemi; hematomun tekrar kırık hattına yerleştirilmesi: deneysel çalışma. Acta Orthop Traumatol Turc 2001; 35: 252-9. [8] Farouk O, Krettek C, Miclau T, Schandelmaier P, Guy P, Tscherne H. Minimally invasive plate osteosynthesis and vascularity: preliminary results of a cadaveric injection study. Injury 1997; 28: 7-12. [9] Borrelli J Jr, Prickett W, Song E, Becker D, Ricci W. Extraosseous blood supply of the tibia and the effects of different plating techniques: a human cadaveric study. J Orthop Trauma 2002; 16: 691-5. [10] Perren SM. Evoluation and rationale of locked internal fixator technology. Introductory remarks. Injury 2001; 32: 3-9. [11] Perren SM, Ganz R. Biological internal fixation of fractures: the balance between biology and mechanics. European Instructional Course Lectures 1997; 3: 161-3. [12] Schaltzker J. Changes in the AO/ASIF principles and methods. Injury 1995; 26: 51-6. [13] Blauth M, Bastian L, Krettek C, Knop C, Evans S. Surgical options for the treatment of severe tibial pilon fractures: a study of three techniques. J Orthop Trauma 2001; 15: 153-60. [14] Muller ME, Nazarian S, Koch P, Schatzker J. The comprehensive classification of fractures of long bones. Berlin: Springer-Verlag 1990; 170-9. [15] Krettek C, Miclau T, Grün O, Schandelmaier P, Tscherne H. Intraoperatif control of axes, rotation and length in femoral and tibial fractures: Technical note. Injury 1998; 29: 29-39. [16] Whelan DB, Bhandari M, McKee MD, et al. Interobserver and intraobserver variation in the assessment of the healing of tibial fractures after intramedullary fixation. J Bone Joint Surg Br 2002; 84(1):15-8.

MIPPO Technique in Distal Tibial Fractures The Open Orthopaedics Journal, 2015, Volume 9 77 [17] Farouk O, Krettek C, Miclau T, Schandelmaier P, Guy P, Tscherne H. Minimally invasive plate osteosynthesis: does percutaneous plating disrupt femoral blood supply less than the traditional technique? J Orthop Trauma 1999; 13: 401-6. [18] Ronga M, Longo UG, Maffulli N. Minimally invasive locked plating of distal tibia fractures is safe and effective. Clin Orthop Relat Res 2010; 468: 975-82. [19] Helfet DL, Shonnard PY, Levine D, Borrelli J Jr. Minimally invasive plate osteosynthesis of distal fractures of the tibia. Injury 1997; 28: 42-7. [20] Lau TW, Leung F, Chan CF, Chow SP. Wound complication of minimally invasive plate osteosynthesis in distal tibia fractures. Int Orthop 2008; 32: 697-703. [21] Borg T, Larsson S, Lindsjo U. Percutaneous plating of distal tibial fractures. Preliminary results in 21 patients. Injury 2004; 35: 608-14. [22] Brinker MR, O Connor DP. Fracture Healing. In: Miller MD, Ed. Review of Orthopaedics. Philadelphia: Elsevier 2004. [23] Perren SM. Physical and biological aspects of fracture healing with special reference to internal fixation. Clin Orthop Relat Res 1979; 138: 175-96. [24] Sommer C, Gautier E, Müller M, Helfet DL, Wagner M. First clinical results of the Locking Compression Plate (LCP). Injury 2003; 34: 43-54. [25] Hasenboehler E, Rikli D, Babst R. Locking compression plate with minimally invasive plate osteosynthesis in diaphyseal and distal tibial fracture: a retrospective study of 32 patients. Injury 2007; 38: 365-70. [26] Jha AK, Bhattacharyya A, Kumar S, Ghosh TK. Evaluation of results of minimally invasive plate osteosynthesis (MIPO) of distal tibial fractures in adults. J Indian Med Assoc 2012; 110: 823-4. Received: November 21, 2014 Revised: February 4, 2015 Accepted: February 15, 2015 Bingol et al.; Licensee Bentham Open. This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited.