Ambulatory blood pressure monitoring has shown that in

Similar documents
BRIEF COMMUNICATIONS. KEY WORDS: Ambulatory blood pressure monitoring, placebo effect, antihypertensive drug trials.

Clinic blood pressure (BP) is greater than ambulatory or

In his article on blood pressure measurement by

Citation Acta medica Nagasakiensia. 1997, 42

Copyright Lippincott Williams & Wilkins. Unauthorized reproduction of this article is prohibited.

Evidence exists indicating that patient adherence to. Frequent Nurse Visits Decrease White Coat Effect in Stage III Hypertension

Clinical Significance of Blood Pressure Response Triggered by a Doctor s Visit in Patients with Essential Hypertension

White Coat Hypertension

Prognostic significance of blood pressure measured on rising

Use and Interpretation of Home Blood Pressure Monitoring

Indirect ambulatory blood pressure monitoring devices

Effect of guanfacine on ambulatory. blood pressure and its variability in elderly patients with essential hypertension

Evaluation of the Baroreceptor-Heart Rate Reflex by 24-Hour Intra-arterial Blood Pressure Monitoring in Humans

Use of ambulatory and home blood pressure (BP) measurements

ANTIHYPERTENSIVE DRUG THERAPY IN CONSIDERATION OF CIRCADIAN BLOOD PRESSURE VARIATION*

& Wilkins. a Division of Cardiology, Schulich Heart Centre, b Institute for Clinical and

In some people blood pressure measured in the office is substantially higher

Does masked hypertension exist in healthy volunteers and apparently well-controlled hypertensive patients?

The magnitude and duration of ambulatory blood pressure reduction following acute exercise

Received 24 February 2015 Revised 29 April 2015 Accepted 20 May 2015

ORIGINAL ARTICLE AMBULATORY BLOOD PRESSURE IN OBESITY. Introduction. Patients and Methods

When should blood pressure be lowered? Should treatment be guided by blood pressure values or total cardiovascular risk?

INCREASED PULSE PRESSURE AND SYSTOLIC x HEART RATE DOUBLE PRODUCT AND CARDIOVASCULAR AUTONOMIC NEUROPATHY IN TYPE 2 DIABETIC PATIENTS

AFFORDABLE TECHNOLOGY

Baroreflex sensitivity and the blood pressure response to -blockade

FOR many years, casual blood pressure (BP)

Ambulatory blood pressure (ABP) may be normal in

How well do office and exercise blood pressures predict sustained hypertension? A Dundee Step Test Study

External Oscillatory Blood Pressure - EOBPTM

White coat hypertension is characterized by a difference

Slide notes: References:

Taking and recording blood pressure and pulse. City Gate Training Centre all rights reserved

Todd S. Perlstein, MD FIFTH ANNUAL SYMPOSIUM

Calculation of Trough-to-Peak Ratio in the Research Unit Setting

Insulin resistance influences 24h heart rate and blood pressure variabilities and cardiovascular autonomic modulation in normotensive healthy adults

EUROPEAN SOCIETY OF HYPERTENSION GUIDELINES FOR THE USE OF HOME BLOOD PRESSURE MONITORING. A SUMMARY REPORT OF THE

Comparison of arbitrary definitions of circadian time periods with those determined by wrist actigraphy in analysis of ABPM data

Evaluation of the Extent and Duration of the ABPM Effect in Hypertensive Patients

Validation of the SEJOY BP-1307 upper arm blood pressure monitor for home. blood pressure monitoring according to the European Society of Hypertension

The Centers for Medicare and Medicaid Services

and bias, which are known to be present in self-home and in professional office BP measurements taken using the auscultatory technique [7].

Carlos A. Segre, Rubens K. Ueno, Karim R. J. Warde, Tarso A. D. Accorsi, Márcio H. Miname, Chang K. Chi, Angela M. G. Pierin, Décio Mion Júnior

CLINICAL SCIENCE. Angela M. G. Pierin a, Edna C. Ignez a, Wilson Jacob Filho b, Alfonso Júlio Guedes Barbato b, Décio Mion Jr. b

Received 30 May 2008 Revised 11 August 2008 Accepted 21 August 2008

Normal Ambulatory Blood Pressure: A Clinical-Practice- Based Analysis of Recent American Heart Association Recommendations

Echocardiographic definition of left ventricular hypertrophy in the hypertensive: which method of indexation of left ventricular mass?

Blood Pressure and Heart Rate Variabilities in Normotensive and Hypertensive Human Beings

BLOOD PRESSURE MEASUREMENT HOME BASED OR OFFICE BP MONITORING WHICH, HOW AND WHEN?

Declaration of conflict of interest

STATE OF THE ART BP ASSESSMENT

Nomogram of the Relation of Brachial-Ankle Pulse Wave Velocity with Blood Pressure

Physiological, Psychological, and Behavioral Factors and White Coat Hypertension. William C. Siegel, James A. Blumenthal, and George W.

ORIGINAL INVESTIGATION. Is Isolated Home Hypertension as Opposed to Isolated Office Hypertension a Sign of Greater Cardiovascular Risk?

Blood Pressure and Heart Rate Variabilities in Normotensive and Hypertensive Human Beings

Importance of Ambulatory Blood Pressure Monitoring in Adolescents

Vital Signs. Vital Signs. Pulse. Temperature. Respiration. Blood Pressure

The measurement of blood pressure and hypertension. Handout Fenyvesi Tamás III.Department of Medicine

NONINVASIVE CHARACTERIZATION OF THE BLOOD PRESSURE RESPONSE TO THE DOUBLE-LEG PRESS EXERCISE

University of Padova, Padua, Italy, and HARVEST Study Group, Italy

White coat and masked hypertension

Hypertension is a risk factor for coronary

DR JIRAR TOPOUCHIAN PROF PAROUNAK ZELVEIAN PROF ROLAND ASMAR. September 8 th, Principal Investigator and Study Chair:

Hypertension is a common medical disorder, affecting. Is Resistant Hypertension Really Resistant? Mark A. Brown, Megan L. Buddle, and Allison Martin

Assessing Blood Pressure for Clinical Research: Pearls & Pitfalls

Please do not hesitate to contact our dedicated service unit for more details regarding this program at

Home hypertension : exploring the inverse white coat response

The main factors that make congestive heart. Treatment of Heart Failure With Fosinopril

1 Department of Medical Physics, Royal Infirmary of Edinburgh, 2 Department of. Received 11 June 2004 Accepted 7 September 2004

BLOOD PRESSURE RESPONSE TO COLD PRESSOR TEST IN SIBLINGS OF HYPERTENSIVES

Abiological parameters display a certain variability.

White-Coat and Masked Hypertension

1. Department of Gynecology and Obstetrics, St. Joseph's Hospital Berlin Tempelhof, Germany

E. HEUDE, P. BOURGIN, P. FEIGEL and P. ESCOURROU Laboratoire du Sommeil, H6pital Antoine Beclere, Clamart, France

Prognostic significance of blood pressure measured in the office, at home and during ambulatory monitoring in older patients in general practice

Ambulatory BP Monitoring: Getting the Diagnosis of Hypertension Right. Anthony J. Viera, MD, MPH, FAHA Professor and Chair

Trough to peak ratio: current status and applicability

DIFFERENTE RELAZIONE TRA VALORI PRESSORI E MASSA VENTRICOLARE SX NEI DUE SESSI IN PAZIENTI IPERTESI.

Working Group on Blood Pressure and Heart Rate Variability European Society of Hypertension

DEVICES AND TECHNOLOGY

The increasing awareness of hypertension as a serious

Special Lecture 10/28/2012

Masked Hypertension: A Review

Ambulatory Blood Pressure Monitoring Clinical Practice Recommendations

Arm position and blood pressure: a risk factor for hypertension?

Copyright Lippincott Williams & Wilkins. Unauthorized reproduction of this article is prohibited.

Validation of the OMRON 705 IT blood pressure measuring device according to the International Protocol of the European Society of Hypertension

HOW CONSISTENT ARE THE BLOOD PRESSURE AND PULSE RATE MEASUREMENTS OF THE ELECTRONIC BP APPARATUS AND THE MANUAL SPHYGMOMANOMETER

Techniques of Vital Signs. John Gazewood, MD, MSPH Department of Family Medicine

INFLUENCE OF GENDER, TRAINING AND CIRCADIAN TIME OF TESTING IN THE CARDIOVASCULAR RESPONSE TO STRESS TESTS

LEARNING OUTCOME The students will be able to elicit vital signs correctly on human volunteers/patients

Does the reduction in systolic blood pressure alone explain the regression of left ventricular hypertrophy?

Association of Heart Rate With Blood Pressure Variability: Implications for Blood Pressure Measurement

Ambulatory blood pressure monitoring (ABPM) is. Accuracy of Ambulatory Blood Pressure Monitors in Routine Clinical Practice.

Section 03: Pre Exercise Evaluations and Risk Factor Assessment

Accuracy and precision of blood pressure determination with the Finapres: an overview using re-sampling statistics

In clinical practice, blood pressure (BP) treatment

An Automated System for Blood Pressure Determination During Exercise

S. Majahalme 1, V. Turjanmaa 2;3, A. B. Weder 4,H.Lu 5, M. Tuomisto 2 and A. Uusitalo 2;3

THE NEW ARMENIAN MEDICAL JOURNAL DISTRIBUTION, AWARENESS, TREATMENT, AND CONTROL OF ARTERIAL HYPERTENSION IN YEREVAN (ARMENIA)

Journal of Hypertension 2004, 22: a Hypertension and Cardiovascular Rehabilitation Unit, Catholic University of

Transcription:

Difference Between Clinic and Daytime Blood Pressure Is Not a Measure of the White Coat Effect Gianfranco Parati, Luisa Ulian, Cinzia Santucciu, Stefano Omboni, Giuseppe Mancia Abstract The purpose of the present study was to evaluate whether the difference between blood pressure measured in the clinic or physician s office and the average daytime blood pressure accurately reflects the blood pressure response of the patient to the physician ( white coat effect or white coat hypertension ). We studied 28 hypertensive outpatients (mean age, 41.8 11.2 years; age range, 21 to 64 years) of 35 consecutive patients attending our hypertension clinic, in whom (1) continuous noninvasive finger blood pressure was recorded before and during the visit, (2) blood pressure was measured according to the Riva-Rocci-Korotkoff method (mercury sphygmomanometer) with the patient in the supine position, and (3) daytime ambulatory blood pressure was monitored with a SpaceLabs 90207 device. The peak blood pressure increase recorded directly during the visit was compared with the difference between clinic and daytime average ambulatory blood pressures. Compared with previsit values, peak increases in finger systolic and diastolic blood pressures during the visit to the clinic were 38.2 3.1 and 20.7 1.6 mm Hg, respectively (mean SEM, P.01 for both). Daytime average systolic and diastolic blood pressures were 135.5 2.5 and 89.2 1.9 mm Hg, with both lower than the corresponding clinic blood pressure values (146.6 3.6 and 94.9 2.2 mm Hg, P.01). These differences, however, were 30% of the peak finger blood pressure increases during the physician s visit, to which these increases showed no relation. Although the visit to the physician s office was associated with tachycardia (9.0 1.6 bpm, P.01), there was no difference between clinic and daytime average heart rates. These data indicate that the clinic daytime average blood pressure difference does not reflect the alerting reaction and the pressure response elicited by the physician s visit and thus is not a reliable measure of the white coat effect. (Hypertension. 1998;31:1185-1189.) Key Words: blood pressure monitoring, ambulatory stress risk factors hypertension, white coat blood pressure Ambulatory blood pressure monitoring has shown that in most subjects, daytime blood pressure is lower than clinic blood pressure. 1 3 This difference is ascribed to the white coat effect (ie, the alerting reaction and pressor response of the patient to the measurement of blood pressure in the clinic environment). 4,5 As a result, subjects with a clinic blood pressure of 140/90 mm Hg and a daytime blood pressure below this value are called white coat hypertensives. 6,7 No demonstration has ever been given, however, that the clinic daytime blood pressure difference is due to a white coat effect and therefore the term white coat hypertension is appropriate. In the present study, we addressed this issue by measuring in the same subjects the clinic daytime blood pressure difference and the actual pressor response to blood pressure measurements by a physician in the clinic environment. Methods Subjects Thirty-five hypertensive patients were considered for inclusion in the study. Seven of the patients were not included in the analysis because of poor-quality ambulatory (n 3) or finger (n 1) blood pressure recording or because of frequent cardiac arrhythmias (n 3), which prevented an accurate blood pressure monitoring from being obtained. Thus, the study population consisted of 28 outpatients (10 men and 18 women) with an age range of 21 to 64 years (mean SD age, 41.8 11.2 years). All patients were seen for the first time in our outpatient center because of the recent detection of blood pressure elevation during a visit with their family physician. The patients were recruited if they had mild essential hypertension (ie, clinic diastolic blood pressure [average of three values] of 91 to 104 mm Hg). Patients were untreated or had their antihypertensive treatment withdrawn for 3 weeks. Additional inclusion criteria were no history or evidence of cerebrovascular, cardiac, or renal complications or damage; no serious concomitant cardiovascular or noncardiovascular disease; no major arrhythmias; body mass index of 27 kg/m 2 ; and evidence of a good-quality finger blood pressure signal (see below) at a preliminary recording session held in the outpatient clinics. The patients consented to the procedure after information was provided that their blood pressure was going to be measured through different techniques to more fully characterize their hypertensive condition. The study protocol was approved by the ethics committee of the institutions involved. Measurements Blood pressure measurements made were those often used for hypertensive patients at our clinic. Clinic blood pressure was Received October 31, 1997; first decision November 21, 1997; revision accepted December 24, 1997. From the Cattedra di Medicina Interna, Ospedale S Gerardo, Monza, University of Milano (G.P., G.M.); Istituto Scientifico Ospedale S Luca, Centro Auxologico Italiano, Milano (G.P., L.U., S.O., G.M.); Centro di Fisiologia Clinica e Ipertensione, IRCCS, Ospedale Maggiore and University of Milano (G.P., L.U., C.S., G.M.), Italy. Correspondence to Dr Gianfranco Parati, Istituto Scientifico Ospedale S Luca, Via Spagnoletto 3, 20149 Milano, Italy. E-mail gparati@imiucca.csi.unimi.it 1998 American Heart Association, Inc. 1185

1186 BP as Measure of White Coat Effect obtained from the nondominant arm with a mercury sphygmomanometer; the first and fifth Korotkoff sounds were taken to identify systolic and diastolic values, respectively. Heart rate was measured according to the palpatory method (30 seconds) after the blood pressure measurement was made. Ambulatory blood pressure recording was obtained for 24 hours with a SpaceLabs 90207 device; the cuff was applied to the nondominant arm. The ambulatory recording was started at 10 AM in the outpatient clinic, after the demonstration that the average of three blood pressure values provided with use of the SpaceLabs device agreed within 5 mm Hg with the average of three values taken simultaneously from the same arm by the auscultatory method via a Y tube connected to a mercury column. The device was set to allow automatic blood pressure measurements every 15 minutes from 7 AM to 11 PM and every 20 minutes from 11 PM to 7 AM. All recordings were performed on working days (Monday through Friday). The subjects were instructed to attend to their usual activity during the recording period and to return to the outpatient clinic the following morning for device removal. Blood pressure also was continuously monitored for 45 minutes with a finger device (Finapres 2300; Ohmeda), which was previously shown to provide values similar to those obtained intra-arterially from the radial artery and to accurately follow rapid and marked changes of intra-arterial blood pressure induced with a variety of stimuli. 8 10 The device cuff was wrapped around the mid or ring finger of the nondominant arm. The finger blood pressure recording was performed in the outpatient clinic with the patient in the supine position and the instrumented hand positioned at the heart level. The device was calibrated at the beginning of the recording by inducing stepwise changes in pressure from 0 to 200 mm Hg through the device pump, which was connected to a mercury column. The recording was started after demonstration that (1) the average of three finger blood pressure values agreed within 7 mm Hg with the average of three values taken simultaneously from the contralateral arm with a mercury sphygmomanometer and (2) the between-arm blood pressure difference was 5 mm Hg. Protocol The study began with a visit by a physician unknown to the patients to measure clinic blood pressure (and heart rate) with the patient in the supine position for 5 minutes. The visit started with a brief patient history and included three sphygmomanometric blood pressure and three heart rate measurements at minutes 3, 5, and 8 of a 15-minute period. It also included a physical examination focused on the cardiovascular system, which was performed in the final minutes of the visit. All patients then underwent the 24-hour ambulatory blood pressure monitoring and the 45-minute finger blood pressure recording, which were obtained within 1 week of the initial visit with a 1- to 2-day interval between each other. To obtain a direct measure of the white coat effect during the 45-minute recording period, the supine patients were visited by another physician they had not previously met. The physician was instructed to measure blood pressure with a mercury sphygmomanometer according to the procedure adopted routinely for hypertensive patients. The visit lasted 15 minutes, and measurements were made at minutes 3, 5, 8, 11, and 13 of the visit. The sphygmomanometric values determined by the physician on this visit were not used to calculate the clinic blood pressure value (which was based on the sphygmomanometric values of the first visit) but were used to determine whether the peak finger blood pressure rise during the visit might coincide with any of the time during which sphygmomanometry was used. In 14 patients, ambulatory blood pressure monitoring preceded the 45-minute finger blood pressure recording period, whereas in the remaining 14 patients, monitoring followed the period. Data Analysis In each patient, the three clinic systolic blood pressure, diastolic blood pressure, and heart rate measurements obtained during the initial visit were averaged and referred to as the clinic blood pressure and heart rate. Systolic blood pressure, diastolic blood pressure, and heart rate values obtained with ambulatory monitoring during the daytime also were averaged. The daytime period was Figure 1. Original finger blood pressure and heart rate tracing showing the pressor and tachycardic effects of the physician s visit in a representative subject. The segment of blood pressure and heart rate tracing between vertical bars corresponds to the time of physician s visit. defined as the period between 7 and 11 AM during which the subject s diary indicated the subject was awake. Finger blood pressure data were recorded (Racal Recorders) and analyzed. First, the analog blood pressure signal was sampled at 168 Hz, converted with a precision of 12 bits, and stored on a computer disk. Second, systolic and diastolic blood pressures were computed for each blood pressure wave, and heart rate was derived as the reciprocal of the interval between consecutive systolic peaks. Third, beat-to-beat values were averaged for each minute of the 45-minute recording. Fourth, average values were obtained for the 10-second period showing the maximal increase in both systolic and diastolic blood pressures during the visit and a 10-second period during the 5 minutes before the visit. The corresponding 10-second heart rate values also were calculated. The differences between clinic and average daytime values were taken as the traditional (and indirect) measure of the white coat effect. Direct assessment of the white coat effect was obtained by computing the differences between peak 10-second finger blood pressure values during the visit and the 10-second values before the visit. Data from individual subjects were pooled and expressed as mean SEM for the group as a whole. The statistical significance of the differences in mean values was assessed with a Student s t test for paired observations. Correlations between direct and indirect measures of the white coat effect were examined by computing Pearson s correlation coefficient. A value of P.05 was taken as the level of statistical significance. Results For the 28 subjects, average clinic systolic and diastolic blood pressures were 146.6 3.6 and 94.9 2.2 mm Hg, respectively. Corresponding daytime values were significantly lower (135.5 2.5 and 89.2 1.9, P.01), and the averages of the individual clinic daytime differences were 11.1 3.5 (systolic) and 5.7 2.4 (diastolic) mm Hg. Thus, according to the conventional indirect approach used with these subjects, there was a noticeable average white coat effect. The 28 subjects showed a marked and persistent increase in finger blood pressure during the physician s visits compared with the measurements during the previsit and postvisit periods (Figs 1 and 2). In most subjects, however, the magnitude of the peak finger blood pressure increase (ie, directly measured white coat effect) was considerably greater than the white coat effect indirectly quantified as the difference between clinic blood pressure (average of three values) and daytime blood pressure.

Parati et al May 1998 1187 Figure 2. Blood pressure (BP) and heart rate (HR) effects of the physician s visit. Data are shown as average SEM 1-minute values of a 15-minute period before the visit, the 15-minute visit (between vertical lines), and a 10-minute period after the visit for the entire group of 28 patients. Systolic (S) and diastolic (D) 1-minute averages are illustrated separately. On average, the peak finger blood pressure increase was 38.2 3.1 mm Hg for systolic blood pressure and 20.7 1.6 mm Hg for diastolic blood pressure, with values more than threefold the average clinic daytime blood pressure differences (Fig 3, top). The peak increase in finger blood pressure directly recorded during the physician s visit and the clinic daytime blood pressure differences also were not significantly related to each other (Fig 3, bottom). This was also true for the corresponding heart rate values. Indeed, although when directly recorded, heart rate showed an average clear-cut increase during the physician s visit, clinic heart rate was on average lower than daytime heart rate (Figs 1 through 3). Figure 4. Timing of the maximal increase in both systolic and diastolic finger blood pressure during the physician s visit. Vertical bars indicate number of subjects showing a maximal blood pressure increase during the 15-minute visit; arrows, timing of cuff blood pressure measurements by the physician. Fig 4 shows the timing of the peak blood pressure response measured directly during the physician s visit. Peak changes occurred at a variable time during the visit, and only in a small number of subjects did they coincide with one of the five sphygmomanometric blood pressure measurements made during the visit. This was reflected by the lack of correlation between the peak increase in finger systolic blood pressure during the physician s visit and the average or highest sphygmomanometric systolic blood pressure value obtained for the visit during which clinic blood pressure was determined (r.23 and.20, respectively; P NS). Similar results were obtained for diastolic blood pressure (r.25 and.20, respectively; P NS). Figure 3. Comparison between the clinic average daytime blood pressure (BP) difference (CBP ABP) and the increase in BP and heart rate (HR) directly measured during the physician s visit (white coat effect [WCE]) (n 28). Both individual and average SEM group data are shown separately for systolic BP (SBP), diastolic BP (DBP), and HR (top). Bottom, Lack of a significant within-subject correlation between CBP ABP and WCE values. Statistical significance of the differences between the two sets of values (P.01).

1188 BP as Measure of White Coat Effect Discussion In our subjects, the increase in blood pressure triggered by the visit of an unfamiliar physician in charge of measuring blood pressure was greater than the difference between conventional clinic and daytime average blood pressures. Furthermore, the physician-dependent increase in blood pressure and the clinic daytime blood pressure difference showed no relation to each other when clinic blood pressure was obtained with an average of three values and when the highest clinic value was considered. Finally, although the increase in blood pressure triggered by the physician was accompanied by a sizable tachycardia, clinic heart rate was on average lower than daytime heart rate. These findings provide evidence that the clinic daytime blood pressure difference does not reliably reflect the alerting reaction and the pressure response elicited in the patient by blood pressure measurement by a physician. Taking this difference as a measure of the white coat effect is therefore erroneous. It consequently is also erroneous to call patients white coat hypertensives if they have a clinic blood pressure of 140/90 mm Hg and a daytime ambulatory blood pressure of 140/90 mm Hg or any other arbitrary blood pressure level. A more appropriate term for these subjects should be the descriptive term isolated clinic hypertensives. 11 Several aspects of the present study deserve discussion. First, it can be suggested that the difference between the higher blood pressure measured in the clinic environment and the lower pressure recorded during the daytime was smaller and unrelated to the white coat effect directly quantified through continuous finger blood pressure recording because previous visits had made the patients less reactive to sphygmomanometric measurements. However, (1) in our patients, direct assessment of the white coat effect always followed the visit in which clinic blood pressure was determined, (2) the diagnosis of hypertension had been made only recently and all patients were seen in our center for the first time, and (3) most importantly, the clinic daytime blood pressure difference is persistent over time (G.P. and G.M., unpublished data from the Study on Ambulatory Monitoring of Pressure and Lisinopril Evaluation [SAMPLE]) and only slightly reduced with treatment. 7,12 Thus, it can be excluded that habituation to sphygmomanometric measurements is responsible for a less pronounced clinic daytime blood pressure difference compared with the directly measured white coat effect. Second, it also can be suggested that the response of finger blood pressure to the physician s visit was greater because of the anxiety inherent to the novelty of the continuous blood pressure monitoring procedure. However, before the physician s visit, finger blood pressure was by no means elevated. Furthermore, and more importantly, in a previous study, we have shown the white coat effect measured directly with continuous blood pressure monitoring to be unchanged for several visits. 5 Thus, that the procedure involved in the direct assessment of the white coat effect caused an exaggerated finger blood pressure response can also be excluded. Third, it can be suggested that the clinic daytime blood pressure difference originates from a white coat effect but fails to reflect the actual size of this phenomenon because as reflected by the lack of correlation between clinic blood pressure and the peak increase in finger blood pressure during the physician s visit, clinic blood pressure measurements seldom correspond to the variable time at which blood pressure shows its maximal increase during the physician s visit (see Fig 4). It should be emphasized, however, that the true white coat effect differed from the clinic daytime blood pressure difference not only quantitatively but also qualitatively (ie, although the true white coat effect was accompanied by tachycardia, the clinic daytime heart rate difference was if anything a negative difference). We thus believe that another possibility is most likely, namely that the clinic daytime blood pressure difference originates not so much from a greater or lesser effect of emotion on clinic blood pressure but rather from factors that modulate daily life blood pressure level and lead to an increase or reduction in daytime blood pressure that may differ among subjects. 13 15 Another possibility, which is not exclusive of the above possibility, is that, of course, as an average of a large number of values, daytime blood pressure achieves an immediate regression to the mean. 7,16,17 A third possibility is that a greater concordance between the true white coat effect and its surrogate measure could be obtained by considering only the ambulatory values around the time at which the visit was made. However, this procedure would be opened to the disadvantage that ambulatory blood pressure within a limited time window has a poor and varying reproducibility. 18 Furthermore, in our study, as in most surrogate assessments of the white coat effect, clinic blood pressure and ambulatory blood pressure were obtained on different days. Three additional points deserve to be made. First, the white coat effect directly measured with continuous finger blood pressure recording is similar to the white coat effect previously documented through intra-arterial blood pressure monitoring. 4,5 Thus, the white coat effect can also be precisely quantified with a noninvasive approach, 19 allowing the direct investigation of a number of important features of this phenomenon that have so far remained unexplored (ie, differences among different hypertensive subgroups, persistence or attenuation with time or different antihypertensive treatments and prognostic significance). Second, the observation that the difference between clinic and daytime blood pressure does not reflect the white coat effect does not deny the pathophysiological and clinical importance of this finding in a hypertensive individual. 20 22 It is important, however, that the mechanisms responsible for this difference are investigated by taking into account not only what increases clinic blood pressure but also what modulates daily life blood pressure. It is also important that its prognostic value is studied separately from the prognostic value of the white coat effect. Its definition as white coat hypertension should therefore be avoided because its origin is different, whereas the clinical significance of the true white coat phenomenon can now be directly investigated. Finally, studies on the clinical significance of the true white coat phenomenon should take into account that previous data obtained through intra-arterial blood pressure monitoring have shown that the blood pressure response to the physician s visit does not correlate with the blood pressure responses to mental arithmetic, with the responses to other laboratory stressors, 23 and with daily life blood pressure variability. 24 Thus, hyperreactivity to an emo-

Parati et al May 1998 1189 tional stimulus does not invariably mean a generalized hyperreactivity to stress. References 1. Sokolow M, Werdegar S, Kain H, Hinman AT. A relationship between level of blood pressure measured casually and by portable recorders and severity of complications in essential hypertension. Circulation. 1966;34: 279 298. 2. Mancia G. Presidential Lecture: Ambulatory blood pressure monitoring: research and clinical applications. J Hypertens. 1990;8(suppl 7):S1 S13. 3. Parati G, Pomidossi G, Albini F, Malaspina D, Mancia G. Relationship of 24-hour blood pressure mean and variability to severity of target organ damage in hypertension. Hypertension 1987;5:93 98. 4. Mancia G, Bertinieri G, Grassi G, Parati G, Pomidossi G, Ferrari A, Gregorini L, Zanchetti A. Effects of blood pressure measurements by the doctor on patient s blood pressure and heart rate. Lancet. 1983;2: 695 698. 5. Mancia G, Parati G, Pomidossi G, Grassi G, Casadei R, Zanchetti A. Alerting reaction and rise in blood pressure during measurement by physician and nurse. Hypertension. 1987;9:209 215. 6. Pickering TG, James GD, Boddie C, Harshfield GA, Blank S, Laragh JH. How common is white coat hypertension? JAMA. 1988;259:225 228. 7. Parati G, Omboni S, Mancia G. Difference between office and ambulatory blood pressure and response to antihypertensive treatment. J Hypertens. 1996;14:791 797. 8. Parati G, Casadei R, Groppelli A, Di Rienzo M, Mancia G. Comparison of finger and intra-arterial blood pressure monitoring at rest and during laboratory test. Hypertension. 1989;13:647 655. 9. Imholz BPM, Van Montfrans GA, Settels JS, Van Der Hoeven GMA, Karemaker JM, Wieling N. Continuous non-invasive blood pressure monitoring: reliability of Finapres device during the Valsalva manoeuvre. Cardiovasc Res. 1988;22:390 397. 10. Idema RN, Van der Meiracker AH, Imholz BPM, Man in t Veld AJ, Ritsema van Eck HJ, Schalekamp MADH. Comparison of Finapres noninvasive beat-to-beat finger blood pressure with intra-brachial artery pressure during and after bicycle ergometry. J Hypertens. 1989;7: S58 S59. 11. Mancia G, Zanchetti A. White-coat hypertension: misnomers, misconceptions and misunderstandings: what should we do next? J Hypertens. 1996;14:1049 1052. 12. Myers MG, Reeves RA. White coat phenomenon in patients receiving antihypertensive therapy. Am J Hypertens. 1991;4:844 849. 13. Mancia G, Zanchetti A. Blood pressure variabilities. In: Zanchetti A, Tarazi R, eds. Handbook of Hypertension, Vol 7: Pathophysiology of Hypertension, Cardiovascular Aspects. Amsterdam, Netherlands: Elsevier; 1986:125 152. 14. Mancia G, Ferrari A, Gregorini L, Parati G, Pomidossi G, Bertinieri G, Grassi G, Di Rienzo M, Pedotti A, Zanchetti A. Blood pressure and heart rate variabilities in normotensive and hypertensive human beings. Circ Res. 1983;53:96 104. 15. Mancia G, Di Rienzo M, Parati G. Ambulatory blood pressure monitoring use in hypertension research and clinical practice. Hypertension. 1993; 21:510 522. 16. Conway J, Coats A. Value of ambulatory blood pressure monitoring in clinical pharmacology. J Hypertens. 1989;7(suppl 3):S29 S32. 17. Trazzi S, Mutti E, Frattola A, Imholz BM, Parati G, Mancia G. Reproducibility of non-invasive and intra-arterial blood pressure monitoring: implications for studies on antihypertensive treatment. J Hypertens. 1991; 9:115 119. 18. Mancia G, Omboni S, Parati G, Trazzi S, Mutti E. Limited reproducibility of hourly blood pressure values obtained by ambulatory blood pressure monitoring: implications for studies on antihypertensive drugs. J Hypertens. 1992;10:1531 1535. 19. Parati G, Omboni S, Mancia G. Experience with continuous non-invasive finger blood pressure monitoring: a new research tool. Homeostasis Health Dis. 1995;36:139 152. 20. Julius S, Mejia A, Jones K, Krause L, Shork N, ven de Ven C, Johnson E, Petrin J, Sekkarie MA, Kjeldsen SE, Schmouder R, Gupta R, Ferraro J, Nazzaro P, Weissfeld J. White coat versus sustained borderline hypertension in Tecumseh, Michigan. Hypertension. 1990;16:617 623. 21. Gosse P, Promax H, Durandet P, Clementy J. White coat hypertension: no harm for the heart. Hypertension. 1993;22:766 770. 22. Kuwajima I, Suzuki J, Fujisawa A, Kuramoto K. Is white coat hypertension innocent? Structure and function of the heart in the elderly. Hypertension. 1993;22:826 831. 23. Parati G, Pomidossi G, Casadei R, Ravogli A, Groppelli A, Cesana B, Mancia G. Comparison of the cardiovascular effects of different laboratory stressors and their relationship with blood pressure variability. J Hypertens. 1988;6:481 488. 24. Mancia G, Parati G. Reactivity to physical and behavioral stress and blood pressure variability in hypertension. In: Julius S, Bassett DS, eds. Handbook of Hypertension, Vol 9. Amsterdam, Netherlands: Elsevier; 1987:104 122.