Akita J Med 44 : , (received 11 December 2017, accepted 18 December 2017)

Similar documents
Evaluation of New Parameters for Assessment of Stroke Impairment

A Measurement of Lower Limb Angles Using Wireless Inertial Sensors during FES Assisted Foot Drop Correction with and without Voluntary Effort

Grip strength is a representative measure of muscle weakness in the upper extremity after stroke

Robot-Assisted Wrist Training for Chronic Stroke: A Comparison between Electromyography (EMG) Driven Robot and Passive Motion

Effects of a Mirror-Induced Visual Illusion on a Reaching Task in Stroke Patients: Implications for Mirror Therapy Training

CRITICALLY APPRAISED PAPER (CAP)

Outcome and Time Course of Recovery in Stroke. Part II: Time Course of Recovery. The Copenhagen Stroke Study

Robot-aided training for upper limbs of sub-acute stroke patients

Augmented reflection technology for stroke rehabilitation a clinical feasibility study

Hand of Hope. For hand rehabilitation. Member of Vincent Medical Holdings Limited

The Stroke Impairment Assessment Set: Its Internal Consistency and Predictive Validity

An EMG-driven Exoskeleton Hand Robotic Training Device on Chronic Stroke Subjects

Activity of Daily Living and Motor Evoked Potentials in the Subacute Stroke Patients Kil Byung Lim, MD, Jeong-Ah Kim, MD

Use of mental imagery to improve task generalisation after a stroke

CORE MEASURE: CORE MEASURE: BERG BALANCE SCALE (BBS)

Arm function after stroke: measurement and recovery

Overview The BBS is a widely-used, clinician-rated scale used to assess sitting and standing, static and dynamic balance.

THE RESPONSIVENESS OF THE ACTION RESEARCH ARM TEST AND THE FUGL-MEYER ASSESSMENT SCALE IN CHRONIC STROKE PATIENTS

Gait dysfunction is a particularly prevalent and important

Inter-rater reliability and validity of the Action Research arm test in stroke patients

Short-Term Recovery of Limb Muscle Strength After Acute Stroke

Are randomised controlled trials telling us what rehabilitation interventions work?

Balance training is an important component of stroke

MINERVA MEDICA COPYRIGHT

Clinical usefulness and validity of robotic measures of reaching movement in hemiparetic stroke patients

ebavir, easy Balance Virtual Rehabilitation system: a study with patients

Berg Balance Scale. CVA, Parkinson Disease, Pediatrics

Int J Physiother.Vol1 (2), 40-45, June (2014) ISSN:

AFTER A STROKE, PEOPLE develop multiple impairments

PERSISTENT LOSS OF upper-extremity (UE) motor function

Trunk Control as an Early Predictor of Comprehensive Activities of Daily Living Function in Stroke Patients

RECOVERY OF LINGUISTIC DEFICITS IN STROKE PATIENTS; A THREE- YEAR-FOLLOW UP STUDY.

Many upper extremity motor function outcome measures do

ECHORD call1 experiment MAAT

TEST-RETEST INTRA-RATER RELIABILITY OF GRIP FORCE IN PATIENTS WITH STROKE

Resting-State Functional Connectivity in Stroke Patients After Upper Limb Robot-Assisted Therapy: A Pilot Study

A ROBOTIC SYSTEM FOR UPPER-LIMB EXERCISES TO PROMOTE RECOVERY OF MOTOR FUNCTION FOLLOWING STROKE

Verification of Immediate Effect on the Motor Function of a Plegic Upper Limb after Stroke by using UR-System 2.2

PDF hosted at the Radboud Repository of the Radboud University Nijmegen

(received 27 December 2013, accepted 17 January 2014) Akita , Japan

CRITICALLY APPRAISED PAPER (CAP)

The device for upper limb rehabilitation that supports patients during all the phases of neuromotor recovery A COMFORTABLE AND LIGHTWEIGHT GLOVE

The device for upper limb rehabilitation that supports patients during all the phases of neuromotor recovery A COMFORTABLE AND LIGHTWEIGHT GLOVE

A Computational Framework for Quantitative Evaluation of Movement during Rehabilitation

Robot-based assessment of motor and proprioceptive function identifies biomarkers for prediction of functional independence measures

TALLGRASS ORTHOPEDIC & SPORTS MEDICINE THROWING ATHLETE EXERCISE PROGRAM TALLGRASSORTHOPEDICS.COM

Abdul-Alim A. Atteya, PhD, PT. ABSTRACT

Featured Article. Elliot J. Roth, MD, Editor

Development of Simple Motion Measurement and Analysis System

DO STROKE REHABILITATION inpatients whose urinary. Urinary Incontinence and Stroke Outcomes. Jan C. Gross, PhD, RN, CS

TRANSFORMER ALL IN ONE ISOKINETIC MACHINE ANKLE ELBOW HIP SHOULDER WRIST TRUNK

Kobe University Repository : Kernel

Prediction of Stroke-related Diagnostic and Prognostic Measures Using Robot-Based Evaluation

Yawning: A Possible Confounding Variable in EMG Biofeedback Studies

THE WORLD HEALTH ORGANIZATION defines mobility

Reliability of the Modified Motor Assessment Scale and the Barthel Index

M ost people who suffer movement problems caused by

Stroke is the most common cause of dependence in

Recovery of Functional Status After Stroke

STUDIES THAT HAVE examined the time course of motor

Please demonstrate each task and/or give instructions as written. When scoring, please record the lowest response category that applies for each item.

A study of the relationship between sit-to-stand activity and seat orientation

Effects of age on functional independence measure score gain in stroke patients in kaifukuki rehabilitation ward

The potential effect of a vibrotactile glove rehabilitation system on motor recovery in chronic post-stroke hemiparesis

Enhanced physical therapy improves recovery of

Stroke patients constitute an increasing challenge

1. Introduction. Correspondence should be addressed to Kenneth N. K. Fong;

ORIGINAL REPORT. J Rehabil Med 2014; 46:

The effects of repetitive task training combined with neuromuscular electrical stimulation on extremities for acute cerebral paralysis

ii. Reduction of tone in upper limb Lycra arm splints improve movement fluency in children with cerebral palsy.

Estimation of the Upper Limb Lifting Movement Under Varying Weight and Movement Speed

Sitting Balance: Its Relation to Function in Individuals With Hemiparesis

Robotics in the Rehabilitation of Neurological Conditions

Arm function after stroke. An evaluation of grip strength as a measure of recovery and a prognostic indicator

테이핑을이용한건측억제유도운동이만성뇌졸중환자의상지기능에미치는영향

Department of Rehabilitation, Kumamoto Kinoh Hospital, Kumamoto, Japan 2. Department of Orthopedic Surgery, Kumamoto Kinoh Hospital, Kumamoto, Japan 3

MANY DIFFERENT OUTCOME measures have been developed

Robotic Finger Rehabilitation Support Device for Home Use An Analysis of the Effect of Finger Rehabilitation for the Upper Limb Function Recovery

Artificial vision gives blindfolded human useful tactile image on a facilitation of motor learning

EVALUATION OF THE ANKLE ROLL GUARD S EFFECTIVENESS TO IMPROVE ITS CLINICAL BENEFIT PROGRESS REPORT. Prepared By:

Comparison of Robot-Assisted Reaching to Free Reaching in Promoting Recovery From Chronic Stroke

914. Application of accelerometry in the research of human body balance

Design and Implementation study of Remote Home Rehabilitation Training Operating System based on Internet

REHABILITATION IN VIRTUAL REALITY VAST.REHAB IS DESIGNED FOR PHYSICAL, OCCUPATIONAL AND COGNITIVE THERAPY

This is the Pre-Published Version.

Transfer of Motor Learning across Arm Configurations

INTRACEREBRAL HEMORRHAGE (ICH) is a major

Electromyogram-Assisted Upper Limb Rehabilitation Device

Expert System-Based Post-Stroke Robotic Rehabilitation for Hemiparetic Arm

/$ IEEE

EFFECTS OF FUNCTIONAL ELECTRICAL STIMULATION IN REHABILITATION WITH HEMIPARESIS PATIENTS

Virtual reality in stroke rehabilitation with the assistance of haptics and telemedicine

Predicting the outcome of acute stroke: prospective evaluation of five multivariate models

THROWERS TEN EXERCISE PROGRAM

Test-retest reliability of the Shape/Texture Identification testtm in people with chronic stroke

Functional Ability Screening Tools for the Clinic

KEY WORDS: Hemiplegia Motor recovery Upper extremity function Functional levels Minimum motion requirement

Navigator: 2 Degree of Freedom Robotics Hand Rehabilitation Device

Founder and Chief Technology Officer, Zyrobotics

Novel Neuromuscular Electrical Stimulation System for the Upper Limbs

Transcription:

Akita J Med 44 : 111-116, 2017 (33) Takashi Mizutani 1), Toshiki Matsunaga 2), Kimio Saito 2), Takehiro Iwami 3), Satoru Kizawa 4), Toshihiko Anbo 3) and Yoichi Shimada 1) 1) Department of Orthopedic Surgery, Akita University Graduate School of Medicine 2) Department of Rehabilitation Medicine, Akita University Hospital 3) Graduate School of Engineering Science, Akita University 4) National Institute of Technology, Akita College (received 11 December 2017, accepted 18 December 2017) Abstract Rehabilitation robot systems for upper limb training of hemiplegic individuals are generally large, difficult to carry, and expensive. There is the need for design of a compact, low - cost robotic system appropriate for widespread dissemination and use. The purpose of this study was to design and construct a new compact and portable rehabilitation robot, and to compare the upper limb function of patients with stroke - induced hemiplegia and healthy volunteers. The subjects were six patients with hemiplegia due to stroke in chronic stage and seven healthy adult volunteers. The upper limb function of each subject was investigated using the new robot system. The parameters for the assessment were Maximum swerve, Average speed, Jerk cost X (horizontal) direction, and Jerk cost Y (Straight) direction. All parameters calculated from the robot trajectory. In stroke group, differences were observed between affected and non - affected sides for both Maximum swerve (p = 0.027) and average speeds (p = 0.045). In control group, there are no differences between dominant and non - dominant hand in all parameters. Comparing affected side in stroke group and dominant side in control group, differences were observed for Maximum swerve, Jerk cost X. The results show that the new device is effective as an assessment instrument objective measurement of upper limb function. Maximum swing width and Jerk cost X is useful parameters to evaluate upper limb function by this device. Key words : rehabilitation robot, hemiplegia, upper limb function Introduction Stroke is a major cause of death in Japan and other countries, and about 70% of the surviving patients pres- Corresponding author : Takashi Mizutani Department of Orthopedic Surgery, Akita University Graduate School of Medicine, 1-1 - 1 Hondo, Akita 010-8543, Japan TEL : 81-18 - 884-6148 FAX : 81-18 - 884-6148 E - mail : mizutanitakashi@med.akita - u.ac.jp ent at least temporary functional impairment of the upper limb 1). It has also been reported that high rate of stroke survivors suffer functional failure of the upper limb 2,3) and that only about 15% are left with useful function 4). Stroke is important disease because it results in disorders that require caregiving and rehabilitation for functional recovery and maintenance. Appropriate assessment is an integral part of physical rehabilitation, because the therapist can plan the effective training strategy from it 5). In the stroke rehabilitation field, the most common scoring systems for motor per- 111

(34) A new tabletop robot for upper extremity rehabilitation formance is the Fugl - Meyer Motor Performance Assessment 6). And, the disability of stroke patient is most commonly measured using the Functional Independence Measure (FIM) 7). Although these measures are widely accepted, standardized and validated, they are still subjective and suffer from low resolution which is typical of ordinal scales 8). Recently, various kinds of robotic technologies have been developed for more accurate assessment of reaching movement 9). Robotic assessments can be objective, quantitative, and continuous scales with less floor or ceiling effects compared to conventional clinical tools 10). In general, rehabilitation robotic systems for upper limb evaluation and training of hemiplegic individuals are large, difficult to carry, and expensive. The stroke patients are required to visit the hospital or other facility to evaluate and train their paralyzed upper limb by such robot devices. Recently, we developed a compact, readily transportable rehabilitation robot for upper limb. It is appropriate for widespread dissemination and use in the stroke upper limb rehabilitation field. The aim of this study was to design and construct a new compact and portable rehabilitation robot for upper limb rehabilitation, and evaluate quantitative upper limb function between the patients with stroke - induced hemiplegia and healthy volunteers by the robot. Materials and Methods 1. Participants Six stroke patients (mean age ; 63.0 ± 12.1 years, 5 men and 1 female, time since stroke ; 63.6 ± 45.6 months) in the chronic phase of stroke - induced hemiplegia (induced by cerebral hemorrhage in three and by cerebral infarction in three ; Brunnstrom stages III - VI) (Table 1, 2) and seven healthy adult volunteers (mean age ; 41.1 ± 22.7 years, 5 men and 2 female) participated in this study. The exclusion criteria were secondary motor neuron dysfunction complication, unstable disease control, and lack of motivation for participation in the ex- Table 1. Demographic and clinical information of stroke patients Number of patients S1 S2 S3 S4 S5 S6 Age 55 49 83 62 59 70 Gender M M F M M M Type of lesion Inf Inf Hem Hem Inf Hem Side of lesion Right Right Left Left Left Left Time since onset (months) 76 42 129 7 30 98 Brunnstrom stage (arm) 4 4 5 4 5 5 Brunnstrom stage (finger) 5 4 5 5 5 5 M : male, F : female Hem : hemorrhagic stroke Inf : infarction stroke Table 2. Summary of the characteristics of stroke patients Characteristic N = 6 Age, mean ± standard deviation (range) 63.0±12.1 Type of disease Cerebral infarction 3 Cerebral hemorrhage 2 Subarachnoid hemorrhage 1 Days after the onset of hemiparesis, median (range) 63.6±45.6 Brunnstrom stage - arm, median (range) 4.5±0.6 Brunnstrom stage - finger, median (range) 4.8±0.4 44 3-4 112

(35) periment. Prior to subject recruitment, review was performed by the Ethics Committee of the Akita University Graduate School of Medicine and Faculty of Medicine, and a determination of conditional approval was received (Acceptance No. 1324). All subjects gave written informed consent prior to screening procedures and recruitment. 2. Composition of rehabilitation robot and system The upper limb rehabilitation device comprises the robot body, the control system, the personal computer (PC) for operation, and the monitor, together with cable connections (Fig. 1). The robot body is very compact, disk - shaped and approximately 300 mm in diameter, 150 mm in height, and 3.5 kg in weight, with a handle on top to move it. The handle is connected internally to a six - axis force sensor that activates the internal motor in response to forces exerted on it by the subject (Fig. 2). The robot has four omnidirectional drive wheels that enable it to move in any direction on a plane (Fig. 3). An augmented reality (AR) marker on the robot is observed by a camera placed directly in front of the monitor to obtain information on the robot position and map its trajectory. The positional information is read by the PC as data related to the base coordinate axis to graphically represent the trajectory and analyze the movements. The PC provides robot operational control, trajectory recording, and related functions. The subject moves the robot while viewing the information displayed on the monitor (Fig. 4). Lateral robot movement is limited to approximately 400 mm to keep its marker within the range of positional information reading via the camera. The system can be readily disassembled and transported, for operation at any location having a table approximately 400 mm square. Fig. 2. Rehabilitation robot and AR marker placed on it Fig. 3. Omni wheel to move the robot in all directions Fig. 1. Overall view of the new rehabilitation robotic system Fig. 4. Screen display on the monitor to manipulate the robot 113

(36) A new tabletop robot for upper extremity rehabilitation 3. Procedure The participants were seated in a chair and operated the robot on the table while viewing the monitor located 500 mm ahead. The chair and table were positioned to obtain an angle of 90 in the elbow joint with the hand resting on the robot. All subjects attempted to repeat three times the forward and rearward reaching movement to and from a point 300 mm ahead without diverging from the line displayed on the monitor. Participants moved the device according to the bar going at the speed of 0.075 m/s on the monitor. They were also asked to assessment tasks using both dominant and non - dominant (stroke : affected and non - affected) hands. 4. Assessment parameters The test parameters for the assessment were Maximum swerve, Average speed, Jerk cost X (horizontal) direction, and Jerk cost Y (Straight) direction. All parameters calculated from the robot trajectory. Maximum swerve was the largest absolute value (mm) recorded during trial. Average speed was the mean value of the measured speeds (m/s) recorded for forward and rearward robot movement. Jerk cost (m 2 /s 6 ) was calculated from Jerk, which represents smoothness, as Jerk cost = J 2 dt (where J = d 3 x/dt 3 and x is the robot X - coordinate displacement 11-13). 5. Data analysis Non - parametric Wilcoxon signed - rank test was used on the data of healthy participants to investigate the difference in performance between the dominant and non - dominant hand and within stroke between affected and non - affected hand. Further, the test was used to identify the combined inter - group differences in control subject s dominant hand with stroke patient s affected hand. Mann - Whitney U test was applied to compare stroke group to control group. The significance level was p < 0.05. Results The results of upper limb performance in hemiplegic and control groups were summarized in table 3. There was no adverse events in all procedures. In the case of stroke group, clear differences were observed between affected and non - affected sides for both Maximum swerve (p = 0.027) and Average speed (p = 0.046). There was no significant difference in Jerk cost X (p = 0.075) and Jerk cost Y (p = 0.753). In the case of control group, the dominant and non - dominant hand performance evaluated. There are no differences between both sides in Maximum swerve (p = 0.204), Average speed (p = 0.498), Jerk cost X (p = 1.000), Jerk cost Y (p = 0.128). Comparing affected side in stroke group and dominant side in control group, clear differences were observed for Maximum swerve, Jerk cost X (p < 0.001, p = 0.014). However, Average speed had no differences. Similarly in the case of stroke patients comparison, there are no difference in Jerk cost Y (p = 0.101). Discussion This study focused on investigating the evaluation of upper limb function and kinematic performance for control of stroke participants using two degrees of freedom platform. The device developed in this study is smaller, less heavy and not expensive than other upper limb rehabilitation robot reported before. The results of this Table 3. Upper limb performance in hemiplegic and control group Hemiplegic patients (N=6) Control (N=7) Affected Non - affected p Dominant Non - dominant p p Maximum swerve (mm) 27.05 (23.05-42.93) 14.95 (10.75-28.35) 0.027 12.1 (7.0-13.6) 9.1 (8.4-13.1) 0.204 0.001 Average speed (m/s) 0.104 (0.071-0.145) 0.071 (0.057-0.104) 0.046 0.083 (0.068-0.090) 0.072 (0.069-0.088) 0.498 0.295 Jerk cost X (m 2 /s 6 ) 3.49 (1.10-11.5) 1.05 (0.458-2.300) 0.075 0.10 (0.00-0.90) 0.1 (0.0-1.6) 1 0.014 Jerk cost Y (m 2 /s 6 ) 50.8 (31.7-67.7) 42.8 (34.2-63.6) 0.753 11.9 (4.80-45.2) 9.8 (3.3-29.5) 0.128 0.101 median (IQR) 44 3-4 114

(37) study showed that movements performed by stroke participants were less smooth and more variable compared to healthy participants. In the following, the results of each evaluation item will be discussed in detail, and future tasks will be discussed. In stroke group, there were differences between affected and non - affected sides for both Maximum swerve and Average speed. Although Jerk cost X had no significant difference (p = 0.075), there was a tendency for the paralyzed side to become larger (not smooth) than on the non - affected side. However, there was no significant difference in Jerk cost Y. Trunk movement affects reaching range - of - motion in stroke patients 14). We did not restrict trunk movement during the test in this study. The possible reason of no difference in jerk cost Y may be the effect of trunk movement that helps smoothness motion in the Y axis (straight) direction. In the control group, there are no differences between dominant and non - dominant hand in all parameters same as previous study 15,16). On the other hand, circle tracing task had significant differences because circle tracing task need more amount of inter - joint coordination than line tracing 15). The line trace task was too easy for control group to compare dominant side and non - dominant side. Inter - group analysis between control and stroke showed clear differences in Maximum swerve, Jerk cost X. However, Average speed had no differences. Similarly in the case of stroke patient comparison, there are no differences in Jerk cost Y. It was reported that movements made with the unaffected limbs of stroke participants were worse than those of controls 15,16). The average speed among stroke group was significantly faster on the affected side than on the non - affected side in this study. This result has two meanings, worse movement on non - affected side and uncontrollable on affected side. The possible reason of no difference in mean velocity was that the average speed became faster without controlling the affected upper limb during the operation of the trace and accordingly it became the same as the average speed on the dominant hand side of the control group. From the above, Maximum swing width and Jerk cost X is useful parameters to evaluate upper limb function by our device. On the other hand, there was room to consider about average speed. The limitations of this study include the age difference between the control and stroke populations. As a part of future studies, we plan to conduct the experiment in elderly adult to remove any variability due to effect of aging. limited. trial. Additionally, the number of stroke participants is We did not restrict trunk movement during After we collect sustainable amount of data and some improvement, it is necessary to investigate correlation with clinical score to understand the clinical relevance of each measure in the future study. In conclusion, the study results show that the new rehabilitation robotic system is effective as an assessment instrument objective measurement of upper limb function, and maximum swing width and Jerk cost X is useful parameters to evaluate upper limb function by this device. This novel device will be useful for examining and training of upper limb in stroke patients. References 1) Nakayama, H., Jorgensen, H.S., Raaschou, H.O. and Olsen, T.S. (1994) Recovery of upper extremity function in stroke patients : the Copenhagen Stroke Study. Arch. Phys. Med. Rehabil., 75, 394-398. 2) Wade, D.T., Langton - Hewer, R., Wood, V.A., Skilbeck, C.E. and Ismall, H.M. (1983) The hemiplegic arm after stroke : measurement and recovery. J. Neurol. Neurosurg. Psychiatry, 46, 521-524. 3) Parker, V.M., Wade, D.T. and Langton - Hewer, R. (1986) Loss of arm function after stroke : measurement, frequency, and recovery. Int. Rehabil. Med., 8, 69-73. 4) Sunderland, A., Tinson, D.J., Bradley, E.L., Fletcher, D., Langton - Hewer, R. and Wade, D.T. (1992) Enhanced physical therapy improves recovery of arm function after stroke. A randomised controlled trial. J. Neurol. Neurosurg. Psychiatry, 55, 530-535. 5) Lang, C.E., Bland, M.D., Balley, R.R., Schaefer, S.Y. and Birkenmeler, R.L. (2013) Assessment of upper extremity impairment, function, and activity after stroke : foundations for clinical decision making. J. Hand Ther., 26, 104-114. 6) Fugl - Meyer, A.R., Jaasko, L., Leyman, I., Olsson, S. and Steglind, S. (1975) The post - stroke hemiplegic 115

(38) A new tabletop robot for upper extremity rehabilitation patient. 1. a method for evaluation of physical performance. Scand. J. Rehabil. Med., 7, 13-31. 7) Hamilton, B.B., Laughlin, J.A., Fiedler, R.C. and Granger, C.V. (1994) Interrater reliability of the 7 - level functional independence measure (FIM). Scand. J. Rehabil. Med., 26, 115-119. 8) Nordin, N., Xie, S.Q. and Wunsche, B. (2014) Assessment of movement quality in robot - assisted upper limb rehabilitation after stroke : a review. J. Neuroeng. Rehabil., 11, 137. 9) Balasubramanian, S., Colombo, R., Sterpi, I., Sanguineti, V. and Burdet, E. (2012) Robotic assessment of upper limb motor function after stroke. Am. J. Phys. Med. Rehabil., 91, 255-269. 10) Scott, S.H. and Dukelow, S.P. (2011) Potential of robots as next - generation technology for clinical assessment of neurological disorders and upper imb therapy. J. Rehabil. Res. Dev., 48, 335-353. 11) Hogan, N. (1984) An organizing principle for a class of voluntary movements. J. Neurosci., 4, 2745-2754. 12) Nagasaki, H. (1989) Asymmetric velocity and acceleration profiles of human arm movements. Exp. Brain Res., 74, 319-326. 13) Chida, S., Matsunaga, T., Sato, M., Hatakeyama, K., Iwami, T., Kosaka, T. and Shimada, Y. (2011) Analysis of reaching movements with the addition of resistance forces in the horizontal and vertical planes using a robot arm in non - disabled individuals. Akita J. Med., 37, 143-152. 14) Mace, M., Guy, S., Hussain, A., Playford, E.D., Ward, N., Balasubramanian, S. and Burdet, E. (2017) Validity of a sensor - based table - top platform to measure upper limb function. IEEE Int. Conf. Rehabil. Robot., 652-657. 15) Hussain, A., Budhota, A., Contu, S., Kager, S., Vishwanath, D.A., Kuah, C.W.K., Yam, L.H.L., Chua, K.S.G., Masia, L. and Campolo, D. (2017) Quantitative assessment of motor functions post - stroke : Responsiveness of upper - extremity robotic measures and its task dependence. Int. Conf. Rehabil. Robot., 1037-1042. 16) Coderre, A.M., Zeid, A.A., Dukelow, S.P., et al. (2010) Assessment of upper - limb sensorimotor function of subacute stroke patients using visually guided reaching. Neurorehabil. Neural Repair, 24, 528-541. 44 3-4 116