Storage: Logix Smart Zika Virus Master Mix and Logix Smart Zika Virus Positive Control must be stored at -20 ⁰C and can last up to 60 days.

Similar documents
Leukemia BCR-ABL Fusion Gene Real Time RT-PCR Kit

Logix Smart ZDC (Zika, dengue, chikungunya)

For in vitro Veterinary Diagnostics only. Kylt Rotavirus A. Real-Time RT-PCR Detection.

Pneumocystis Carinii Real Time PCR Kit. For In Vitro Diagnostic Use Only User Manual

altona RealStar Instructions for Use RealStar CMV PCR Kit /2017 EN DIAGNOSTICS

MolecularMD. One-Step qrt-pcr BCR-ABL Kit. Product Description and User Manual. For Quantitative RT-PCR Analysis of BCR-ABL. Contact Us.

Instructions for Use. RealStar Influenza Screen & Type RT-PCR Kit /2017 EN

Instructions for Use. RealStar Influenza S&T RT-PCR Kit /2017 EN

1. Intended Use New Influenza A virus real time RT-PCR Panel is used for the detection of universal influenza A virus, universal swine Influenza A vir

Norgen s HIV proviral DNA PCR Kit was developed and validated to be used with the following PCR instruments: Qiagen Rotor-Gene Q BioRad icycler

Product # Kit Components

HIV-1 Viral Load Real Time (RG)

Norgen s HIV Proviral DNA PCR Kit was developed and validated to be used with the following PCR instruments: Qiagen Rotor-Gene Q BioRad T1000 Cycler

Cytomegalovirus (CMV) End-Point PCR Kit Product# EP36300

RealLine Mycoplasma genitalium Str-Format

AmoyDx TM BRAF V600E Mutation Detection Kit

Kit Components Product # EP42720 (24 preps) MDx 2X PCR Master Mix 350 µl Cryptococcus neoformans Primer Mix 70 µl Cryptococcus neoformans Positive

Single Cell Quantitative Polymer Chain Reaction (sc-qpcr)

RealLine HIV quantitative Str-Format

AquaPreserve DNA/RNA/Protein Order # Preservation and Extraction Kit 8001MT, 8060MT

altona DIAGNOSTICS altona DIAGNOSTICS RealStar CMV PCR Kit 1.0 always a drop ahead. 11/2012

RealLine HBV / HCV / HIV Str-Format

ABIOpure TM Viral (version 2.0)

EXO-DNAc Circulating and EV-associated DNA extraction kit

EXO-DNA Circulating and EV-associated DNA extraction kit

Midi Plant Genomic DNA Purification Kit

RealLine HCV Qualitative Str-Format

RealLine HIV qualitative Str-Format

virellatbe real time RT-PCR Kit LC

HBV Real-TM Quant Handbook

Human Rotavirus B. Non structural protein 5 (NSP5) 150 tests. Quantification of Human Rotavirus B genomes Advanced kit handbook HB10.01.

virotype Influenza A RT-PCR Kit Handbook

(DNA) Real-time PCR. Exicycler 96 Rotor-Gene Q/6000 PCR

(DNA) Real-time PCR. Exicycler 96 Rotor-Gene Q/6000 PCR

Standard Operation Procedure (SOP) for Biobanking Sampling Procedure Manual Use

Influenza A viruses Detection with real time RT-PCR reagents

HIV DNA Qual FRT Real Time Kit

RealLine HCV quantitative Str-Format

E.Z.N.A. SQ Blood DNA Kit II. Table of Contents

EPIGENTEK. EpiQuik HDAC2 Assay Kit (Colorimetric) Base Catalog # P-4006 PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE

Product Contents. 1 Specifications 1 Product Description. 2 Buffer Preparation... 3 Protocol. 3 Ordering Information 4

PRODUCT: RNAzol BD for Blood May 2014 Catalog No: RB 192 Storage: Store at room temperature

Manual FTD BCE. Quantitative assay for in vitro diagnostics

For purification of viral DNA and RNA from a wide range of sample materials

artus CMV TM PCR Kit Handbook

Real Time Kit. Pneumocystis jirovecii (carinii) Real-TM Handbook. for the detection of Pneumocystis jirovecii (carinii) in biological materials

Retro-X qrt-pcr Titration Kit User Manual

INSTRUCTION MANUAL. RNA Clean & Concentrator -5 Catalog Nos. R1015 & R1016. Highlights. Contents

Pinpoint Slide RNA Isolation System II Catalog No. R1007

AmpliX HBV Quantitative

Roche Molecular Biochemicals Application Note No. HP 1/1999

For Research Use Only Ver

Human Rotavirus C. genesig Advanced Kit. DNA testing. Everything... Everyone... Everywhere... Non structural protein 5 (NSP5) 150 tests

EpiQuik Circulating Acetyl Histone H3K18 ELISA Kit (Colorimetric)

Product Contents. 1 Specifications 1 Product Description. 2 Buffer Preparation... 3 Protocol. 3 Ordering Information 4 Related Products..

CMV Real-TM Quant. REF List Number Store at 2-8 C/-20 C. RUO For Research Use Only Caution! LOT Lot Number VER Version.

Validation Report: VERSA Mini PCR Workstation Reverse Transcription of Avian Flu RNA and Amplification of cdna & Detection of H5N1

XTRAKT FFPE Kit / Manual

Human influenza A virus subtype (H3) genesig Easy Kit for use on the genesig q reaction. Primerdesign Ltd

CMV FEP ALA For nucleic acid amplification of CMV DNA and Fluorescence detection with End Point analysis (FEP) on Aladin (Sacace)

ab HIV-1 Protease Inhibitor Screening Kit (Fluorometric)

Sputum DNA Collection, Preservation and Isolation Kit 50 Individual Devices

Exosome ELISA Complete Kits

Phosphate buffered saline (PBS) for washing the cells TE buffer (nuclease-free) ph 7.5 for use with the PrimePCR Reverse Transcription Control Assay

ab Exosome Isolation and Analysis Kit - Flow Cytometry, Cell culture

Exosome ELISA Complete Kits

For Research Use Only Ver

Avian Influenza A H5N8

RealLine HCV Quantitative - Uni-Format

HDV Real-TM Quant Handbook

For Research Use Only Ver

Human Rotavirus A. genesig Advanced Kit. Non structural protein 5 (NSP5) 150 tests. Primerdesign Ltd. For general laboratory and research use only

ab HRV 3C Protease Inhibitor Screening Kit (Colorimetric)

respirarna 2.0 real time RT-PCR Kit

Human Rotavirus A. genesig Standard Kit. Non structural protein 5 (NSP5) 150 tests. Primerdesign Ltd. For general laboratory and research use only

Human Apolipoprotein A1 EIA Kit

ab Mammalian Cell Lysis Buffer 5X

SERUM GLUCAGON KITS PROTOCOL

ab Glucose Uptake Assay Kit (colorimetric) 1

Procine sphingomyelin ELISA Kit

RayBio Phenylalanine Fluorometric Assay Kit

QIAsymphony DSP Circulating DNA Kit

WHO Emergency Use Assessment and Listing for Zika IVDs PUBLIC REPORT. Product: RealStar Zika Virus RT-PCR Kit 1.0 EUAL Number: EAZ

HDV Real-TM. Handbook

virellatropica 1 real time RT-PCR Kit

altona RealStar Instructions for Use RealStar CMV PCR Kit /2017 EN DIAGNOSTICS

Prodesse ProFAST + Assay

Urine - Based CMV PCR Detection Kit Product # 36300

INFINITI FLU A-sH1N1 Assay Directional Package Insert (DPI)

Human TSH ELISA Kit. User Manual

Product Manual. Omni-Array Sense Strand mrna Amplification Kit, 2 ng to 100 ng Version Catalog No.: Reactions

Ascorbic Acid Assay Kit

For Research Use Only Ver

Prodesse ProFlu + Assay

CDC Human Influenza Virus Real-Time RT-PCR Diagnostic Panel (CDC Flu rrt-pcr Dx Panel)

Avian influenza A virus subtype (H9)

Mouse serum Insulin 200 tests

Transcription:

Logix Smart Zika Virus (ZIKV-K-003; ZIKV-PC-003; GEN-NTC-001) Description The Logix Smart Zika Virus Test developed by Co-Diagnostics, Inc. detects ribonucleic acid (RNA) of Zika Virus in a single step reverse transcription real-time PCR reaction. Real-time PCR detection is recommended for detection of Zika Virus during the acute stages of infection before the production of antibodies, which is typically <14 days after the mosquito bite. Zika virus testing helps prevent the transmission of virus prior to pregnancy, transfusion or transplantation, sexual relation, or the exchange of body fluids. The Logix Smart Zika Virus Test detects the virus within 40 cycles from serum or plasma samples. In each Logix Smart Zika Virus supplied is a complete, ready-to-use master mix. Simply add the extracted viral RNA sample to the master mix and run! A human RNaseP gene marker serves as an Internal Control (IPC) to monitor the quality of each reaction and is designed to also detect inadequate samples. Components 1x 500 µl (100 rxns) Logix Smart Zika Virus Master Mix (ZIKV-MM-003) 1x 500 µl Logix Smart Zika Virus Control (ZIKV-PC-003) 1x 500 µl Nuclease Free Water (GEN-NTC-001) Materials required (not included): Pipettes capable of transferring 5 µl Ice Vortex Centrifuge Real-time PCR System with FAM (green) or Cal Fluor 610 (orange) dyes or equivalent and accompanying tubes/plates and caps/films Storage: Logix Smart Zika Virus Master Mix and Logix Smart Zika Virus Control must be stored at -20 ⁰C and can last up to 60 days. WARNING! To prevent degradation of reagents in s: 1) Immediately store Logix Smart Zika Virus Master Mix and Logix Smart Zika Virus Control at or below -20 C 2) Always work with each Logix Smart Zika Virus Master Mix and Logix Smart Zika Virus Control on ice 3) Return components of Logix Smart Zika Virus Master Mix and Logix Smart Zika Virus Control to the -20 C freezer immediately after using 4) Make aliquots if necessary to avoid multiple freeze/thaw cycles Upon receipt of the Logix Smart Zika Virus Master Mix and Logix Smart Zika Virus Control, check to make sure there is excess dry ice in the shipment and that the reagents are Page 1 of 8

still completely frozen. If there are any problems with the shipment please contact your distributor immediately. Immediately store the Logix Smart Zika Virus Master Mix and Logix Smart Zika Virus Control at -20 C. If you work in an area prone to power outages it is extremely important that you have a back-up generator for your freezer as well as a temperature data log to ensure that the Logix Smart Zika Virus Master Mix and Logix Smart Zika Virus Control remain frozen at -20 C. Reagents must remain frozen at all times (or on ice when in use) to prevent degradation. While working with thawed components of Logix Smart Zika Virus Master Mix and Logix Smart Zika Virus Control it is extremely important that the reagents are kept on ice at all times. Return the reagents to the freezer immediately after use, and make aliquots to avoid multiple freeze/thaw cycles. Intended Use: The Logix Smart Zika Virus is intended for molecular biology applications. This product is not intended for the diagnosis, prevention, or treatment of a disease. This product is for export only and is not for sale in the United States. Sample Extraction Recommendations The Logix Smart Zika Virus has been validated with serum or plasma samples collected in serum separator (red) or EDTA (purple) vacutainers and extracted using the QIAamp Viral RNA Mini Kit (Qiagen, Cat No. 52904). Real-time PCR Setup To prevent contamination, it is recommended to use Good Molecular Laboratory Practices that follow a uniflow process and separation of negative and positive materials. All real-time PCR master mix, positive controls, negative controls, and samples should be briefly spun down to remove residue from the lids after storage or mixing. Thaw all reagents and samples on ice before starting setup. All reagents must remain on ice for the duration of real-time PCR setup. In the designated negative control setup area: 1. Thaw Logix Smart Zika Virus Master Mix (ZIKV-MM-003) on ice (for minimum time possible). 2. Vortex and centrifuge Logix Smart Zika Virus Master Mix for a max 3 seconds. 3. Put the Logix Smart Zika Virus Master Mix on ice. *All steps involving Logix Smart Zika Virus Master Mix should be performed on ice or on a frozen tray 4. Put PCR tubes on ice. 5. Aliquot 5 ul of Logix Smart Zika Virus Master Mix into desired wells. 6. Add 5 ul Nuclease Free Water (GEN-NTC-001) to the appropriate well(s). In the designated positive control area (preferably separated from the master mix setup area to avoid contamination) Page 2 of 8

7. Thaw extracted/purified RNA on ice (if frozen). 8. Vortex and centrifuge purified RNA for a few seconds. 9. Add 5 ul of purified RNA sample to each well using a new tip between each sample. 10. Thaw Logix Smart Zika Virus Control (ZIKV-PC-003) on ice (for minimum time possible). 11. Vortex and centrifuge Zika Virus PC for a few seconds. 12. Add 5 µl of Zika Virus PC to appropriate well(s). 13. Place caps on the tubes according to the real-time system being used. 14. Put plate/tubes in real-time PCR machine and start the run. Thermal Cycling Setup Program the thermal cycler to the following conditions for a total reaction volume of 10μL: Temperature Time Cycles Capture 55 C 10 minutes N/A 95 C 20 seconds N/A 95 C 3 seconds N/A 55 C 32 seconds 45 FAM (Green) and Cal Fluor Red 610CF610 (Orange) Interpretation of Results 1. When the run is finished, ensure that the run file is saved. 2. Check to see that the controls passed. Analyzing Controls Controls: Highlight the positive control reaction well. Each positive control should show two amplification curves similar to that seen below: IPC (CF610) ZIKV (FAM) Figure 1. Control Amplification Page 3 of 8

Range for Control Ct Values* ZIKV (FAM) 20-26 IPC (CF610) 16-19 Logix Smart Zika Virus Table 1. Control Ranges for Cycle Threshold Values ZIKV (FAM): Zika Virus Marker IPC (CF610): RnaseP Internal Control Marker *Ct values may vary by ± 2 cycles based on instrument differences. If the Ct values do not match the graph, then the threshold or the baseline must be manually changed until the values represent the growth curves. The threshold must be set as close to the start of the growth curve and above the background noise. The baseline must be set before the first amplification curve. Check the instrument user manual for instructions for adjusting the threshold or baseline. If the positive control does not show amplification, then the tests are invalid. Loss of amplification for a positive control is indicative of primer degradation which may result from reagents being at temperatures above -20 C for more than one hour or being used past the expiration date. Pipetting error may also account for lack of positive control amplification by pipetting control into the wrong well, missing a well, or pipetting an inadequate amount of reagent into a reaction well. Negative Controls: Next highlight the negative control. The results of the negative control should show results similar to those seen below: ZIKV (FAM) Negative IPC (CF610) Negative Figure 2. Negative Control Amplification Page 4 of 8

Occasionally, ubiquitous binding will cause amplification of RNaseP as seen in the figure below: ZIKV (FAM) Negative IPC (CF610) Figure 3. Ubiquitous Binding of Negative Control If the negative control shows any amplification of ZIKV <40 cycles the results are invalid and the entire experiment must be repeated. Amplification of ZIKV in a negative control indicates contamination in one or more of the reagents or pipetting error. Amplification of ZIKV >40 cycles is outside the detectable range and is considered negative. Analyzing Samples Once the controls have passed, the unknown samples can be interpreted based on three possible outcomes (figures may vary based on machine used and quantity of MM and sample): 1. (figures 4 and 5) 2. Negative (figure 6) 3. Negative Due To Inadequate Nuclear Material (figure 7) A result will show an amplification curve or cycle threshold value for ZIKV at or below 40 cycles. Amplification curves greater than 40 cycles for ZIKV are outside of the detection limits for the assay. A positive sample will have the following curves: Page 5 of 8

IPC (CF610) ZIKV (FAM) Figure 4. ZIKV positive sample: The presence of a curve for ZIKV (FAM) indicates a positive result. The amplification of the IPC (CF610) shows that the extraction was successful. ZIKV (FAM) IPC (CF610) Negative Figure 5. ZIKV positive sample: The presence of a curve for ZIKV indicates a positive result even when the RNase P (IPC) marker is negative. This will occur when the concentration of ZIKV is greater than the concentration of RNaseP or when using cell lysates or extremely pure/sterile samples. A Negative result will show no amplification for ZIKV; however, occasionally amplification greater than 40 cycles occurs in ZIKV or RNaseP channels. Any amplification curves greater than 40 cycles for ZIKV are outside of the detection limits for the assay. A negative sample result will have the following curve: Page 6 of 8

IPC (CF610) ZIKV (FAM) Negative Figure 6. ZIKV negative sample: The absence of a curve for ZIKV indicates a negative result ONLY when the RNase P (IPC) marker is positive. A Negative Due To Inadequate Nuclear Material result will have the following curve: ZIKV (FAM) Negative IPC (CF610) Negative Figure 7. Negative Due To Inadequate Nuclear Material: If the RNase P (IPC) control marker is also negative, then the result is negative due to inadequate nuclear material. This can be the result of human error in sample prep, sample degradation, or an inadequate sample. The test may be repeated with a new sample or called negative due to inadequate nuclear material. Note: Samples obtained from culture or sterile/pure sites (e.g. CSF, urine, cell lysates, etc) may not contain RnaseP. In such case, the two negative markers indicate a true negative result for zika virus. Page 7 of 8

For Information or Questions: Phone: +1 (801) 438-1036 Email: info@codiagnostics.com Website: www.codiagnostics.com Page 8 of 8