International Journal of Science and Research (IJSR) ISSN (Online): Index Copernicus Value (2013): 6.14 Impact Factor (2013): 4.

Similar documents
Laparoscopic Hernia Repair, Indications, Superiority and Outcome

JMSCR Vol. 03 Issue 08 Page August 2015

C. Nikkolo, T. Vaasna, M. Murruste, H. Seepter, Ü. Kirsimägi, U. Lepner

Early Outcome Of Inguinal Hernia Repair Using Ultrapro Mesh In University Of Calabar Teaching Hospital, Nigeria

From the Unit of General and Geriatric Surgery, School of Medicine, Department of Surgery, Second University of Naples, Italy

Designed to help advance patient outcomes and ease of use

Systematic review and meta-analysis of the use of lightweight versus heavyweight mesh in open inguinal hernia repair

B. Braun Mesh Range It s All about Prevention. Experts in Abdominal Wall Health. Hernia Repair

JMSCR Vol 05 Issue 03 Page March 2017

Meshes. Meshes. Non-absorbable meshes. Absorbable meshes

M. Jmietajski K. Bury I. A. Jmietajska R. Owczuk T. Paradowski The Polish Hernia Study Group

Tissue-Separating Mesh A Comparative Guide

A comparative study of postoperative complications of lightweight mesh and conventional prolene mesh in Lichtenstein hernia repair

Laparoscopic Repair of Inguinal Hernia with Biomimetic Matrix

Evidence Summary. Ethicon Hernia Portfolio. Better surgery for a better world

VALUE ANALYSIS COMMITTEE PRODUCT INFORMATION KIT

Expert Technologies in PVDF

II.- PLUG. NAME of the products. Premilene Mesh Plug MANUFACTURER. B Braun DESCRIPTION. Polypropylene mesh for plug technique

NiTiNol Hernia Device Stability in Inguinal Hernioplasty Without Fixation

In the surgical treatment of inguinal hernia, the use of

Comparison of partially-absorbable lightweight mesh with heavyweight mesh for inguinal hernia repair: multicenter randomized study

SDRP JOURNAL OF ANESTHESIA & SURGERY

Key words: inguinal hernia, Lichtenstein technique, non-absorbable and partially absorbable mesh.

Mesh Related Infections in Hernia Surgery: A Case Report and Review of Literature

COMPARISON OF OUTCOMES (EARLY AND LATE) FOLLOWING OPEN AND LAPAROSCOPIC REPAIR OF INGUINAL HERNIAS: AN EXPERIENCE OF A SINGLE SURGICAL UNIT

Technique Guide. Bard MK Hernia Repair. Featuring Modified Onflex Mesh SOFT TISSUE REPAIR. Anterior Approach to a Preperitoneal Inguinal Hernia Repair

Liberiamoci dalla Rete. Oltre l Evidenza

Titanium coated light weight polypropylene meshes in inguinal hernia repair: A prospective study

INSTRUCTIONS FOR USE FOR:

Ventralex ST Hernia Patch featuring Sepra Technology

34 yo M presented in ER of KCH at 7/06/10 Painful lump lt groin + vomiting Pain started 2 hrs before presentation. PMH known left inguinal hernia PSH

Randomized clinical trial comparing self-gripping mesh with a standard polypropylene mesh for open inguinal hernia repair

A comparative study of inguinal hernia repair: Shouldice versus Lichtenstein repair

Hernia surgery: from guidelines to clinical practice

ALLOPLASTIC CLOSURE OF DEFECTS IN GROWING ORGANISMS*

Inguinal Hernia and Comparison between Mesh Repair and Conventional Repair of Hernia with Respect to Hernia Recurrence: A Clinical Study

J of Evolution of Med and Dent Sci/ eissn , pissn / Vol. 4/ Issue 77/ Sept 24, 2015 Page 13279

Hernia repair: the search for ideal meshes

A Comparative Study between sutureless and Lichtenstein inguinal Mesh hernioplasty

A Randomised Control Study on Neurosensory Outcomes of lioingunal Neurectomy in Lichtenstein s Hernia Repair

with Laparoscopic Ventral Hernia Repair Positioning System SOFT TISSUE REPAIR Designed for Accurate Mesh Centering

Use of Biologics in Abdominal Wall Reconstruction

BIOFIBER. Absorbable Biologic Scaffolding Solutions

No Mesh Technique of Inguinal Hernia Repair Desarda s Repair

Repair of inguinal hernia utilizing external oblique muscle sheath as posterior wall strengthening and placing spermatic cord subcutaneously

Open Journal of Pain Medicine. Chronic Pain after Laparoscopic Inguinal Hernia Repair Depends on Mesh Implant Features: A Clinical Randomised Trial

INGUINAL HERNIORRHAPHY WITH AN UNDETACHED STRIP OF EXTERNAL OBLIQUE APONEUROSIS: A NEW APROACH USED IN 400 PATIENTS (Eur J Surg 2001 Jun;167(6):443-8)

Mædica - a Journal of Clinical Medicine STATE-OF-THE-ART. , Danut VASILE. University of Medicine and Pharmacy Carol Davila Bucharest, Romania

Abdominal Wall Hernias in Upper Egypt: A Different Spectrum.

Title at a Single Institution. Issue Date Right.

3/21/2011. Advances in laparoscopic ventral hernia repair. Laparoscopic approach well-suited for simple hernias:

Keywords TEP repair Lightweight mesh Heavyweight mesh Chronic groin pain Mesh awareness Quality of life

This short decision aid is to help you decide what treatment to choose if you have an inguinal hernia.

Needlescopic Surgery Versus Single-port Laparoscopy for Inguinal Hernia

Randomized clinical trial of laparoscopic hernia repair comparing titanium-coated lightweight mesh and medium-weight composite mesh

Light weight meshes in incisional hernia repair

OptiFix Absorbable Fixation System

2015 General Surgery Survival Guide

CAT FOR TREATMENT. Clinical Scenario:

A New Open Minimal Access Approach for Mesh Repair of Inguinal Hernia

1. Introduction. 2. Material and methods Methodology

Assessment and comparison of laparoscopic hernia repair versus open hernia: a non-randomized study

Titanised mesh implants for urogynaecology Transvaginal multi-arm meshes Incontinence tapes Instruments Laparoscopic meshes

Objectives. Hesselbach s Triangle 11/30/2009. Myopectineal Orifice of Fruchaud. Hernias: Who, What, When, Where, Why?

Tension-Free Inguinal Hernia Repair: TEP Versus Mesh-Plug Versus Lichtenstein

The role of prophylactic cefazolin in the prevention of infection after various types of abdominal wall hernia repair with mesh

Inguinal Hernia Repair by Surgical Trainees at a Malaysian Teaching Hospital

Positioning System. Laparoscopic ventral hernia repair KEY BENEFITS SOFT TISSUE REPAIR

JMSCR Vol 04 Issue 04 Page April 2016

Journal of Innovations in Pharmaceuticals and Biological Sciences

Facing a Hernia Repair?

Inguinal hernia surgery

Hallén, Magnus; Sandblom, Gabriel; Nordin, Pär; Gunnarsson, Ulf; Kvist, Ulrik; Westerdahl, Johan

Is Laparoscopic Groin Hernia Repair Better Than Open Mesh Repair?

[Dinajpur Med Col J 2016 Jul; 9 (2): ] Key words: Inguinal, hernia, Desarda

Titanized Mesh Implants Hernia Surgery

SURGICAL TREATMENT OF INCISIONAL HERNIAS

The Use of Synthetic Polymer Meshes in the Correction of Pelvic Static Defects

A modified Lichtenstein hernia repair using fibrin glue

Inguinal Hernia. Incarcerated hernia

Evaluating postherniorrhaphy groin pain: Visual Analogue or Verbal Rating Scale?

TRIALS. Abstract. Schouten et al. Trials 2012, 13:76

Surgical repair of vaginal wall prolapse using mesh

Assessment of Efficacy of Local and General Anaesthesia in Patients Undergoing Inguinal Hernia Repair: A Comparative Study

Clinical Study Skin Staples: A Safe Technique for Securing Mesh in Lichtensteins Hernioplasty as Compared to Suture

Transabdominal pre peritoneal (TAPP) vs totally extraperitoneal (TEP) laparoscopic techniques for inguinal hernia repair

Hernia Surgery in Adults

Nerve management during open hernia repair

Conoscere e riconoscere i propri errori. L importanza di un registro internazionale il modello EURAHS. Ferdinando Agresta

Hernias Umbilical Hernia When to See a Surgeon? What Are Symptoms of an Umbilical Hernia? How is Repair Performed?

LAPAROSCOPIC TOTAL EXTRAPERITONEAL INGUINAL HERNIA REPAIR: A STUDY AT RAWALPINDI MEDICAL COLLEGE AND ALLIED TEACHING HOSPITALS ABSTRACT

DGAFMS MEDICAL MEMORANDUM ON INGUINAL HERNIA AND THEIR DISPOSAL. 2. Three Primary causes can be distinguished in the etiology of Hernia.

Echo PS Positioning System with Ventralight ST Mesh or Composix L/P Mesh

Setting The study setting was tertiary care. The economic study was carried out in the USA.

ANALYSIS OF SURGICAL TREATMENT OF VENTRAL HERNIA FOR PATIENTS WITH OBESITY

Study of open inguinal hernia repair by mosquito net mesh versus polypropylene mesh

4D Mesh Flat et 4D Mesh Anatomique

REINFORCED BIOSCAFFOLDS

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

A prospective comparison of ambulatory endoscopic totally extraperitoneal inguinal hernioplasty versus open mesh hernioplasty

Transcription:

Comparative Study on the Application of Surgipro Partiene Mesh and Light Partiene Mesh, in Patients with Inguinal Hernia Surgery with the Lichtenstein Method Dr. Gordana Bozhinovska - Beaka MOB "th September" - Skopje Abstract: Introduction: According to historical data treatment of inguinal hernia is one of the first surgical interventions made by human worldwide, annually operating around one million patients, applying different operating techniques. Object of the paper: To make a comparison of the results in patients with inguinal hernia operated by the Lichtenstein method using SURGIPRO PARIETENE MESH AND LIGHT PARIETENE MESH, in the incidence of post-operative pain, post-operative wound infection, time of post mobilization and days of hospitalization. Material and Methods: This study analyzed 0 patients with inguinal hernia operated in the period between 0.0 -.. 0, ate the unit for digestive surgery at MOB "September " in Skopje. Of these, patients are inserted with SURGIPRO mesh, and with LIGHT meshes. All patients were operated under general anesthesia with the Lichtenstein method. Results: This paper is a comparative study involving 0 subjects with inguinal hernia. Of these, at surgery in (N) patients are embedded Light - meshes, and (N) Surgipro meshes. Regarding age there is no statistically significant difference between the patients from both groups (Mann-Whitney U Test: Z = - 0,9 p = 0,) The VAS - scale of to 0 patients in the first group N postoperative day confirmed present Boca average volume of,0 ±,0 and patients confirmed the presence of N on average volume of ±,. The difference in terms of days of hospitalization was statistically significant in relation to the occurrence of infection; there is no statistically significant difference between both groups. Keywords: inguinal hernia, surgical meshes, operational techniques. Introduction According to historical data on treatment of hernia is one of the first surgical interventions made in humans. It is safe to say that nowadays hernia is the leading diagnosis in the population especially among males. The ratio between male and female is high "advantage" in favor of men. Worldwide, annually around one million patients are being operated, applying different operating techniques. () In making a hernia repair in patients with hernia depends on factors such as the type of the hernia, the patient's age and the physical appearance of the patient may make direct hernia repair with suture or using mesh (,) The modern era of hernia repair begins 0 years ago with the use of monofilament woven meshwork of a previous direct suture of the defect. (,) By definition, surgical alloplastic meshwork is an artificial material that is used to strengthen the abdominal wall. It may be of biological material, made of plastic or combine both types of material in making mesh shaver must meet certain standards series: to be permanent, to have the ability to restore the integrity of the abdominal wall, easy to operate, be able to better integration in native tissues, low foreign body reaction to be resistant to infection and have the ability to adjust / reclined natural structures covered. In making the mesh used to strengthen the abdominal wall, you should consider several important points: the material from which it is made by the meshwork structure of the thread that is woven / woven meshwork, the method of creating the meshwork - a woven / knitted and the characteristics of the meshwork (meshwork strength, elasticity, thickness, material memory, softness, porosity and (,, ) wrinkling of the web).. Objectives of the paper In this paper we compare the results obtained in patients who used two types of meshes: SURGIPRO MESH AND PARIETENE LIGHT MESH A Surgipro meshes is a monofilament polypropylene mesh, made of polypropylene monofilament thread. It is a sterile inert porous mesh with thickness 0.mm suitable for manual and mechanical fixation with Tucker. The size of the pores is. 0.h0.mm and weight 9gr / m Knitted is thus bidirectional provides elasticity. It is easy to cut it with particularly high tension strength (strength of support). It falls into the category of heavy mesh with low porosity and economically worthwhile. A light-weight mesh is a monofilament polypropylene mesh, made of polypropylene monofilament thread. It is inert and sterile mesh with obvious tension strength. Wicker is thus allows multidirectional elasticity and easy stitching. The mesh s thickness is of 0. mm and is suitable for manual mechanical fixation to fixation tackers. The size of the pores which is hexagonal and is optimal,x,mm. The weight of the meshwork is -gr / m, and falls into the category (,, ) of simple mesh works with optimal porosity. Paper ID: SUB9

Object labor: to make a comparison of the results in patients with inguinal hernia operated by the method of Lichtenstein using Surgipro meshes and Light-weight meshes, in the incidence of post-operative pain, post-operative wound infection, time of postoperative mobilization and days of hospitalization. studied groups used the Student - t test for independent samples. To determine the significance of differences of data with irregular distribution is applied the non-parameter Mann-Whitney U Test.. Results. Material and methods The paper analyzed 0 patients with inguinal hernia operated in the period between 0.0 -.. 0, at the unit for digestive surgery at MOB "September " in Skopje. Of these, patients had the Surgipro mesh put in, and Light-weight meshes. All patients were operated on under general anesthesia by the method of Lichtenstein. Both types of meshes that are used are monofilament polypropylene mesh that can be distinguished in terms of porosity and weight (g / m ). These two types of meshes are suitable for placing in all types of inguinal hernia and invingoscrotal. The choice of the type of mesh placed in participants was made randomly. When analyzing the data with the correct distribution, to determine the significance of differences between the two This paper is a comparative study involving 0 subjects with inguinal hernia. Of these, at surgery in (N) patients are embedded Light - meshes, and (N) Surgipro meshes. In terms of gender, 9 subjects were male, and the woman was placed Light - mesh. N patients were an average age of ±, years and N patients were an average age of ±, years. In terms of age does not exist statistically significant difference between patients of both groups (Mann-Whitney U Test: Z = - 0,9 p = 0,) (Table. and Chart. ) Table : Average values of respondents according to age / years Studied groups average CO Min. Max. N.0..0.0 N.0..0 0.0 0 возраст / години 0 0 0 0 N N испитувани групи Graph : Average values of respondents according to age / years Mean Mean±SE Mean±SD The VAS - scale of to 0 patients in the first group N postoperative day confirmed present Boca average volume of,0 ±,0 and N patients confirmed present Boca average volume of, ±,. Notation difference in postoperative pain among the tested groups is statistically significant, ie, the pain is significantly stronger in patients who built Surgipro mesh. (Student - t test: t = -,00 p = 0,0). Patients operated from inguinal hernia with the Lichtenstein method using Light - meshes were hospitalized an average of,0 ± 0,9 day, and patients who were implanted Surgipro meshes were hospitalized an average of, ±, days. The difference in terms of days of hospitalization was statistically significant (Table no. ) Patients in the first group studied (N) the occurrence of wound infection was noted in only one patient (%), while in the second group examined the occurrence of surgical wound infection (Cerro) is registered in (%) patients. In terms of incidence of infection, no statistically significant difference was spotted between both groups. (Table no. ) Paper ID: SUB9

Table : Significance of the difference in days of hospitalization and incidence of surgical wound infection in patients from both groups Mann-Whitney U Test variables Rank Sum Rank Sum U Z p-level days of hospitalization.0.0.0 -.9 0.0000 * occurrence of infections.0.0.0-0.99 0. * Statistically significant difference In order to see whether the age influence the length of hospitalization and severity of post-operative pain of patients according to VAS - scale, an analysis of the linear correlation. Determined that there is little weak positive correlation between the age of the patients and the number of days of hospitalization (r = 0,9), i.e., elderly patients have a longer hospitalization period. 0 Correlation: r = 0,9 9 денови на хоспитализација 0 0 0 0 0 0 0 0 90 возраст/години 9% confidence Graph : Correlation between age and postoperative hospital stay Between the age of patients and postoperative pain by VAS - scale, there is a high positive correlation and strong (r = 0,9) - older patients postoperative pain assessed as stronger. Correlation: r = 0,9 VAS - скала 0 0 0 0 0 0 0 0 0 90 возраст / години 9% confidence Graph : Correlation between age and the intensity of the post-operational pain. Paper ID: SUB9

There is a medium strong positive correlation between the days of hospitalization and postoperative pain in patients by VAS scale. Correlation: r = 0, VAS - скала 0 9 0 денови на хоспитализација 9% confidence Graph : Correlation between the days of hospitalization and severity of postoperative pain. Discussion This paper analyzes the results obtained when comparing the two groups of patients in making a hernia repair is implanted difference types of meshes. Included are a total of 0 subjects with inguinal hernia, which at surgery in (N) patients are embedded Light - meshes, and (N) Surgipro meshes. In terms of gender, 9 subjects were male. According to literature, the inguinal hernia pathology is very (9, 0) common in men. N patients were an average age of ±, years and N patients were an average age of ±, years. In terms of age, there is no statistically significant difference between patients of both groups. Nadim Khan associates refer to the average age of the operated patients were operated from inguinal hernia and analyzed in their labor is, ±, years. ( ) This clue indicates that patients in our country for many years live with inguinal hernia, and decide on an operation when the hernia will start to seriously affect the quality of daily life at older ages. Patients operated inguinal hernia by the Lichtenstein method that is used in Light - mesh were hospitalized an average,0 ± 0,9 day, and patients who used Surgipro mesh were hospitalized an average of, ±, days. The difference in days of hospitalization, resulting in post-operative pain of patients, patient's age and bio-characteristics of the placed (,, ) mesh. According to VAS - scale of to 0, a difference in terms of postoperative pain between our respondents from both examined groups was noted and it is significant to mention - the pain is significantly stronger in patients who built Surgipro mesh. In the consulted literature on this subject is obtained similar results, whereby age is emphasized as an important factor that influences the intensity of pain VAS - (,, ) scale and duration of hospitalization. Patients whose results were analyzed and elaborated in this paper, the presence of postoperative infection was observed in a small number of patients in both groups. Easy elevated rates of incidence of infection in patients, who used Surgipro meshes, are probably due to the quality of the tissue, that is, a relation between ages of the operated patients and biomechanical characteristics of the various meshes (, ) themselves. References [] Klinge U, Klosterhalfen B, Birkenhauer V, Junge K, Conze J, Schumpelick V. Impact of polymer pore size on the interface scar formation in a rat model. J Surg Res. 00; 0: 0 -. [] The EU Hernia Trialists Collaboration. Repair of groin hernia with synthetic mesh: meta-analysis of RCT. Ann Surg. 00; : -. [] Nixon SJ, Jawaid H. Recurrence after inguinal hernia repair at ten years by open darn, open mesh and TEP - no advantage with mesh. Surgeon. 009; : -. [] Klosterhalfen B, Junge K, Klinge U. The light Weight and Large Porous Mesh Concept for Hernia Repair. Expert Rev Med Dev ISSN. 00: -0. [] Post S, Weiss B, Willer M, Neufang T, Lorenz D. Randomized clinical trial of lightweight composite mesh for Lichtenstein inguinal hernia repair. Br J Surg. 00; 9: -. [] Schumpelick V, Klinge U. The properties and clinical effects of various types of mesh used in hernia repair. Association of Great Britain and Ireland (Yearbook) 00 Paper ID: SUB9

[] Klinge U, Klosterhalfen B, Birkenhauer V, Junge K, Conze J, Schumpelick V. Impact of polymer pore size on the interface scar formation in a rat model. J Surg Res. 00; [] Anderson JM, Miller KM. Biomaterial, biocompatibility and the macrophage. Biomaterials. 9; : -0. [9] Piper JV. A comparison between whole thickness skin graft and Bassini methods of repair of inguinal hernias in men. Br J Surg. 99; : -. [0] Post S, Weiss B, Willer M, Neufang T, Lorenz D. Randomized clinical trial of lightweight composite mesh for Lichtenstein inguinal hernia repair. Br J Surg. 00; 9: -. [] Nadim Khan, AdilBangash, MuzaffaruddinSadiq, AinUlHadi, and Haris Hamid : Polyglactine / Polypropylene Mesh Vs. Propylene Mesh: Is There a Need for Newer Prosthesis in Inguinal Hernia? Saudi J Gastroenterol. 00 Jan-Mar; (): - a thirteenth [] O'Dwyer PJ, Kingsnorth AN, Molloy RG, Small PK, Lammers B, Horeyseck G. Randomized clinical trial assessing impact of a lightweight or heavyweight mesh on chronic pain after inguinal hernia repair. Br J Surg. 00; 9: -0. [] Kehlet H, Bay-Nielsen M, Kingsnorth A. Chronic postherniorrhaphy pain-a call for uniform assessment. Hernia. 00; : -. [] O'Dwyer, Kingsworth AN, Molloy RG, Small PK, Lammers B, Horeyseck G. Randomized clinical trial assessing impact of a lightweight or heavyweight mesh on chronic pain after inguinal hernia repair. Br J Surg. 00; 9: -0. [] Polish Hernia Study Group. Surgical site infections after mesh hernioplasty -analysis of two series of patents.hernia. 00; 9: th [] Klinge U, Junge K, Spellerberg B, Piroth C, Klosterhalfen B, Schumpelick V. Do multifilament alloplastic meshes increase the infection rate? J Biomed Mater Res.00; : -. Paper ID: SUB9 9