Dr Emma Chung. Safety first - Physical principles for excellent imaging

Similar documents
Lesson 03: Sound Wave Propagation and Reflection. This lesson contains 15 slides plus 14 multiple-choice questions.

The Physics of Ultrasound. The Physics of Ultrasound. Claus G. Roehrborn. Professor and Chairman. Ultrasound Physics

Principles of Ultrasound. Cara C. Prideaux, M.D. University of Utah PM&R Sports Medicine Fellow March 14, 2012

Diploma of Medical Ultrasonography (DMU) Physical Principles of Ultrasound and Instrumentation Syllabus

ULTRASOUND IMAGING EE 472 F2018. Prof. Yasser Mostafa Kadah

Ultrasound Physics and Knobology Alan Macfarlane. Consultant Anaesthetist Glasgow Royal Infirmary

Preamble (disclaimer)

Ultrasound Physics & Doppler

What is Ultrasound? Resolution Image production Attenuation Imaging modes Ultrasound artifacts... 7

Ultrasound. Principles of Medical Imaging. Contents. Prof. Dr. Philippe Cattin. MIAC, University of Basel. Oct 17th, 2016

Basic of Ultrasound Physics E FAST & Renal Examination. Dr Muhammad Umer Ihsan MBBS,MD, DCH CCPU,DDU1,FACEM

Ultrasound Principles cycle Frequency Wavelength Period Velocity

Ultrasound Physics & Terminology

Chapter 14. Imaging Artifacts

Basic Physics of Ultrasound and Knobology

Diagnostic Ultrasound. Sutiporn Khampunnip, M.D.

Sound in medicine. CH.12. Dr.Rajaa أ.م.د. رجاء سهيل جنم جامعة تكريت كلية طب االسنان. General Properties of Sound

ULTRASOUND. OB/Gyn (Core) Ultrasound PIEZOELECTRIC EFFECT. Principles of Ultrasound Physics and Instrumentation. Nathan Pinkney, BS, CDOS

1 Fundamentals. Basic Definitions and Physics Principles. Fundamentals

Basic Ultrasound Physics Board Review Questions

Basic Physics of Ultrasound in Transesophageal Echocardiography

Terminology Tissue Appearance

Physical Principles of Ultrasound

CONTENTS. Test Number cpd Tanya Reynolds (Nat. Dip. Diag. Rad., B. Tech. Diag. Rad., B. Tech. Ultrasound)

DIGITAL IMAGE PROCESSING IN ULTRASOUND IMAGES

Ultrasonic Testing Level I:

Lesson 07: Ultrasound Transducers. This lesson contains 73 slides plus 16 multiple-choice questions.

Application of Phased Array Radar Theory to Ultrasonic Linear Array Medical Imaging System

Ultrasound guidance in regional anesthesia has

WELCOME! Introduction to Bedside Ultrasound

The 2 nd Cambridge Advanced Emergency Ultrasound Course

Introduction to Ultrasound Guided Region Anesthesia

Point-of-Care Ultrasound: An Introduction

What is Ultrasound? What is Ultrasound? B A. Basic Principles of Ultrasound. Basic Principles of Ultrasound. Basic Principles of Ultrasound

Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion

Critical Care Ultrasound Study Notes

Introduction to Biomedical Imaging

Supplement (videos)

Ultrasound: Past and Present. Lecturer: Dr. John M Hudson, PhD

Pulse-Echo Ultrasound Imaging. Resolution in Ultrasound Imaging. Doppler Ultrasound. Resolution vs Penetration. Medical Imaging (EL582/BE620/GA4426)

Descriptions of NDT Projects Fall 2004 October 31, 2004

Ultrasound Knobology

Ultrasound Applied Physics

Linear Ultrasonic Wave Propagation in Biological Tissues

Ultrasonic arrays are now widely used in underwater sonar

4.17. RESEARCHING MODELS WITH AN ULTRASONIC ECHOSCOPE

Chapter 2 Pitfalls in Musculoskeletal Ultrasound

Concepts of Imaging and Knobology

Emergency Medicine Interest Group (EMIG) 2016

Routine Quality Assurance Cookbook

Ultrasound in Anesthesia: Applying Scientific Principles to Clinical Practice

1. SCOPE ELIGIBILITY EXAMINATION CONTENT RENEWAL & RECERTIFICATION PROCEDURE ESSENTIAL READING...

4.17. RESEARCHING MODELS WITH AN ULTRASONIC ECHOSCOPE

1. Fig. 1 shows data for the intensity of a parallel beam of X-rays after penetration through varying thicknesses of a material

Q1. The diagram shows an ultrasound monitor being used to scan a fetus.

Underwater Acoustic Measurements in Megahertz Frequency Range.

TG-128: Quality Assurance for Prostate Brachytherapy Ultrasound

The Essentials Tissue Characterization and Knobology

The Evolution and Benefits of Phased Array Technology for the Every Day Inspector

Physical Principles of Ultrasound

Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion

Medical Imaging. By: Engr. Joseph Ronald Canedo

Performance of phased array and conventional ultrasonic probes on the new ISO reference block

Physics. Norman McDicken Tom Anderson CHAPTER ULTRASOUND. Ultrasound Propagation

Breast Imaging Essentials

Image optimization for critical care US

Non-Destructive Inspection of Composite Wrapped Thick-Wall Cylinders

Thyroid Ultrasound Physics and Doppler

Chapter 1. Principles of medical ultrasound. Overview. Background history: first steps to the piezo-electric effect.

Lectures on Medical Biophysics Dept. Biophysics, Medical faculty, Masaryk University in Brno

3/20/2017. Disclosures. Ultrasound Fundamentals. Ultrasound Fundamentals. Bone Anatomy. Tissue Characteristics

DIAGNOSTIC TECHNIQUE OF ABNORMALITIES IN BALL BEARINGS WITH AN ULTRASONIC METHOD

INTRODUCTION. Getting the best scan. Choosing a probe. Choosing the frequency

Flaw Assessment Using Shear wave Phased array Ultrasonic Transducer

Current Ultrasound Quality Control Recommendations and Techniques

The table below shows the density and velocity of waves in two different substances. Density / kg m 3 Velocity / m s 1

APPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS

Ultrasound Measurements and Non-destructive Testing Educational Laboratory

Introduction & Physics of ED Ultrasound. Objectives. What? - Limited Studies. Who? - ED Docs

Table of contents. Foreword. Preface. 1 Introduction Historical Perspective 00

ULTRASOUND NOMENCLATURE

CSB 046 Complementary Imaging Techniques

Roaa M.Hussein Professor, Department of Physics, College of Science, Ramadi, Iraq. Abstract:

Evaluation of the Quality of Thick Fibre Composites Using Immersion and Air- Coupled Ultrasonic Techniques

Ultrasonic Testing of Composite Structures

Tissue Strain Analytics Virtual Touch Tissue Imaging and Quantification

Debbie Childs RDMS, RVT Sonographer Murphy Medical Center Murphy, NC

STUDY OF PHASED ARRAY TECHNIQUES FOR CONCRETE INSPECTION

Chapter 3 Physical Principles of Ultrasound of the Male Genitalia

Application of ultrasonic phased array in acoustic logging

White Paper. iqprobes

Principles of echocardiography for the anesthesiologist.

An Overview of Ultrasound Testing For Lesion Detection in Human Kidney

Numerical Modelling of Ultrasonic Phased Array Transducers and Their Application

Chapter 17 Sound Sound and Hearing. Properties of Sound Waves 1/20/2017. Pearson Prentice Hall Physical Science: Concepts in Action

A new method of sonograph lateral resolution measurement using PSF analysis of received signal

Basic Training Programme. 16 Februrary 2018, ROTTERDAM. Pre and Post-Course Test Answers

US Artifacts 1 EDUCATION EXHIBIT. Myra K. Feldman, MD Sanjeev Katyal, MD Margaret S. Blackwood, MS

Ultrasound in Medicine

Optimization of Phased-Array Transducers for Ultrasonic Inspection in Composite Materials Using Sliding Probes

Transcription:

Safety first - Physical principles for excellent imaging Dr Emma Chung Lecturer in Medical Physics, University of Leicester Clinical Scientist, University Hospitals of Leicester NHS Trust Thanks to Caroline Banahan, David Evans, and Kumar Ramnarine for use of images

Safety first! Look after your scanners and do regular checks to make sure your equipment is working properly If in doubt call Medical Physics and ask for an ultrasound Quality Assurance (QA) check When scanning keep an eye on the TI and MI, and follow the BMUS safety guidelines to keep within recommended scan times - Safety and quality are your responsibility!

Ultrasound physics What you see is not always what you get!? How can I visualise boundaries in the image? How do I get good resolution and improve the accuracy of my measurements? What generates image contrast? How can I identify and reduce artefacts?

What is ultrasound? Compression Rarefaction c = f Ultrasound is high frequency mini sound. Typical medical ultrasound frequencies (f) are between 2 and 20 MHz (well above the range of human hearing). Medical ultrasound wavelengths ( ) are between ~1 mm and 0.1 mm. Perfect for receiving echoes from structures in the body! Sound is a pressure wave (a push ) It needs a medium to propagate. The speed of sound depends on the density and stiffness of the tissue In soft tissue, sound moves at a speed (c) of approximately 1540 m/s. Ultrasound over 100 khz can be created using tiny tuning forks and whistles as sources

Using echolocation to visualise our surroundings Daniel Kish bat boy Daniel and his students are able to recognise many aspects of their surroundings by clicking their tongues and analysing the resultant echoes.

Pulse-echo ultrasound In pulse-echo systems, the transducer emits a short pulse of ultrasound and is then used to listen for echoes reflected back to the transducer. time/2 ultrasound transducer time/2 distance scatterer depth = time/2 x Speed of Sound If you know the Speed of Sound this makes it possible to plot echo intensity as a function of depth to build up an image of the echoes. The frequency with which pulses are emitted and received is called the Pulse Repetition Frequency (PRF) the PRF can be higher for shallower depths.

Speed of sound in biological materials, c Material c (m/s) Density, (kg/m 3 ) Air 343 1.2 Fat 1450 952 Soft tissue average 1540 m/s Liver 1550 1060 Kidney 1560 1038 Muscle 1580 1080 Blood 1575 1057 Bone 3500 1912 The relative closeness of the values of velocity within the body is crucial for ultrasound imaging. Ultrasound scanners assume an average speed of sound for soft tissue of c =1540 m/s c = f 7

Speed of sound artefacts Objects with speed of sound significantly different from c=1540 m/s will cause distortion of axial distances causing: Misregistration of targets Distortion of interfaces Errors in sizing Defocusing of the ultrasound beam The fat get fatter on ultrasound!? The lower speed of sound of fat mean that axial distances are displayed slightly further from the transducer than they actually are. Fat c = 1420 ms -1 Tissue c = 1540 ms -1 Target is displayed at

Ultrasound Imaging To create a 2D image using ultrasound we need 3 key pieces of information: 1. The axial distance of the target from transducer (range/depth) given by the time of arrival of the pulse (assuming 1540 m/s) 2. Lateral position of target given by the location/direction of the beam 3. Brightness of the target (greyscale value) given by the echo amplitude

Amplitude-mode (A-mode) scanning There are various ways to build-up an ultrasound image:. A-mode, B-mode, M-mode... In A-mode scanning you simply emit a pulse and plot echo intensities from a single beam with depth. A-Mode scanning in Japan in the late 1950s

Brightness-mode (B-mode) and Motion-mode (M-mode): People quickly realised that you could join these echoes together to create a 2D image, where echo amplitude is displayed as the brightness of the image (B-mode) B-mode image. Alternatively, you could record how the amplitude of the echoes varies with time: M-mode (Motion-mode) imaging. M-mode.

Early B-mode scanning In early B-mode scanners, the subject often had to sit in a bath and the transducer was moved or rotated mechanically to build up the image line by line. The Somascope was a waterimmersion motorised B-mode scanner developed by Howry, Bliss, Posakony and Cushman - and appearing in Life Magazine in 1954.

A conventional imaging probe... The linear stepped array transducer Transducer elements are fired in groups. By firing groups of (e.g. 5) elements together, this forms a larger aperture which generates a parallel beam. After the pulse is transmitted, the same group can be used to receive the returned echoes. The active groups is then stepped along the array by dropping an element from one side of the group and adding an element to the other side.

The linear array transducer A traditional linear array transducer has128 elements, each controlled by a separate electrical connection. The elements have a backing layer to damp vibrations; this allows short pulses to be produced. A matching layer between the transducer elements and the cylindrical lens helps to improve transmission of ultrasound into the tissue. A cylindrical lens is attached to the front face of the transducer to focus ultrasound into the imaging plane (this defines the slice thickness ).

Slice thickness With the use of linear arrays, US beams can be focussed and steered electronically to build up images in real-time. Lateral resolution. Axial resolution Beam width The cylindrical lens limits elevation and defines the slice thickness. Lateral localisation depends on pulse timing, lateral resolution depends on beam geometry (which varies with depth) Axial localisation depends on echo time and axial resolution depends on pulse length Courtesy T A Whittingham

Slice thickness artefact Image from http://prosono.ieasysite.com/03_sono_interp_mar_09.pdf

Axial resolution Axial resolution is the ability to separate two objects lying along the line of the US beam Determined by pulse duration ( pulse duration /2) Diagnostic Ultrasound Hoskins, Martin, Thrush

Lateral resolution Lateral resolution is determined by beam width. This usually varies with depth. For a focused transducer, the best lateral resolution will be at the focal region. Lateral resolution tends to be worse than axial resolution! Curvilinear In a curvilinear array transducer the line density decreases with depth, which reduces the lateral resolution. Diagnostic Ultrasound Hoskins, Martin, Thrush

Variations: the phased array transducer The phased array transducer is similar to the linear array transducer, however, the elements are very narrow ( /2) and the transducer face is approximately square. Rather than firing the elements in groups ALL elements are fired together for each transmission. This transducer enables us to peek between structures such as the ribs perfect for echocardiography! Courtesy T A Whittingham

Choice of probe and scanner assumptions Transducers come in lots of shapes and sizes with frequencies and transducer arrays tailored to suit particular imaging applications. General scanner assumptions: 1. The speed of sound is constant at 1540 ms -1. 2. The attenuation varies consistently with depth. 3. The ultrasound beam and echoes always travel in a straight line (and don t bounce around before coming back to the probe!) If these assumptions are not met this gives rise to artefacts.

The US wave and tissue Reflections The acoustic impedance tells us about how ultrasound waves are moving through the tissue. It is related to the density and stiffness of the tissue. Z = c When ultrasound moves through a boundary between materials with very different acoustic impedances this generates a strong reflection. Material Z (Rayls) Air 0.0004 x 10 6 Blood 1.62 x 10 6 Bone 3.75-7.38 x 10 6 Brain 1.55-1.66 x 10 6 Fat 1.35 x 10 6 Kidney 1.62 x 10 6 Liver 1.64 x 10 6 Lung 0.26 x 10 6 Muscle 1.65-1.74 x 10 6 Soft tissue (average) 1.63 x 10 6 Water 1.48 x 10 6 Biological materials that are stiff and dense have the highest acoustic impedances

Contrast in the image reflection and scattering What happens when ultrasound encounters a smooth boundary between materials with very different density and speed of sound? Source incident wave reflected wave Z 1 Z 2 transmitted wave

Reflection artefacts - reverberation In the presence of two parallel boundaries a reverberation artefact can be observed at multiple equally spaced depths in the image Sound bounces back and forth between tissue boundaries and then returning to the probe. (multiple scattering) This patient has a pacemaker in the chest wall. From: Artifacts. W. K. Chooi, Valdair Muglia, and Peter L. Cooperberg. In Diagnostic Ultrasound by McGahan and Goldberg (2008).

Reflection artefacts mirror artefact A reflection off of the diaphragm (short arrow) can be seen at an angle of reflection equal to the angle of incidence back to the hemangioma within the liver. Mirror image artefact The US machine does not know that the beam was deflected and displays the image of the lesion as though it were in the base of the lung. From: Artifacts. W. K. Chooi, Valdair Muglia, and Peter L. Cooperberg. In Diagnostic Ultrasound by McGahan and Goldberg (2008).

Refraction artefact Refraction has potential to change both the apparent angular position and distance of a target in an ultrasound image. Source I II c 1 > c 2 Actual target position c 1 c 2 Apparent target position Even though the beam has changed direction the ultrasound scanner will assume the ultrasound has traveled in a straight line at a speed of sound of 1540 m/s. This artefact is also angle dependent.

Refraction artefact How will a refracting surface affect the appearance of the rectangle and circle in the ultrasound image? The scanner assumes ultrasound travels in a straight line, so the position of the circle will be misrepresented as lying along the beam axis.

Refraction artefact Edge shadowing from cystic regions e.g. gall bladder Beam refracts as it enters the cystic region Edge shadowing artefact The beam is stepped to consecutive positions along the array, so the angle of incidence on upper surface of cyst increases. refraction is most rapid at the cyst edge

Diagnostic Ultrasound Hoskins, Martin, Thrush Specular and diffuse reflection Specular reflection only occurs when the target is very much larger than the wavelength of the ultrasound, and is strongly angle dependent. The greatest reflected intensity will be observed when the beam is at 90 to the scattering surface. - You can effectively reflect ultrasound out of the beam by angling the probe. Most reflectors within the body are not perfect specular reflectors and possess a degree of roughness of the scale of a wavelength. This means they will reflect an incident wave over a range of angles (diffuse scattering).

Ultrasound speckle An inherent characteristic of ultrasound imaging is the speckle appearance of tissue. Within tissue, there are many small scale variations in acoustic properties - these scatter diffusely in all directions, combining to give rise to a speckle pattern. The speckle appearance of tissues tends not to change significantly with beam angle.

Attenuation and absorption As the beam travels through the tissue it loses energy through various processes such as reflection (from boundaries), scattering (e.g. speckle) and absorption (conversion to HEAT). The intensity of the ultrasound beam decreases exponentially as it passes through tissue (which is linear on the db scale!) 50% I = I 0 exp( d ) 25% 12.5% d (cm) I 0 and I are the initial and final intensity of the beam and d is the distance from the transducer. is an attenuation coefficient.

Time-gain compensation All scanners apply a time-gain compensation function to compensate for attenuation this makes the drop-off in intensity of the image with depth less noticeable.

ARTEFACTS??? How will an object with strong attenuation compared to the surrounding tissue affect the appearance of the ultrasound image? The intensity of the beam will be reduced beyond the bright object, casting an acoustic shadow over the tissue beyond.

ARTEFACTS??? How will an object with weak attenuation compared to the surrounding tissue affect the appearance of the ultrasound image? Regions beyond the object experience a more intense ultrasound beam than the surrounding tissue causing acoustic enhancement

Penetration depth Each material has its own attenuation coefficient measured in db/cm. Attenuation increases linearly with US frequency! Therefore the attenuation co-efficient is more generally expressed as =0.5 db cm -1 MHz -1 Material (db cm -1 MHz -1 ) Liver 0.399 Brain 0.435 Muscle 0.57 Blood 0.15 Water 0.02 Bone 22 Diagnostic Ultrasound Hoskins, Martin, Thrush

Trade-off between penetration and resolution In any imaging technique we wish to use the shortest wavelengths possible to improve resolution (remember that the fundamental limit of resolution is approximately one wavelength) BUT.because attenuation increases rapidly with increasing frequency this limits penetration depth. Lower frequencies are typically used for deeper tissue penetration or imaging through bone. Higher frequencies are typically used to maximise resolution for visualising superficial structures. Lower US frequencies have worse resolution but can see further! 35

Thank you! That s why we use different frequency probes for deep an superficial imaging! but, it is your handling of the probe and understanding of US settings (and physics) to dynamically optimise the US image that sets ultrasound sonographers apart from other imaging modalities. Harness your inner physicist to become a better Sonographer! 36