Effect of intra-abdominal hypertension on left ventricular relaxation: a preliminary animal study

Similar documents
The Patient with Atrial Fibrilation

Effect of Heart Rate on Tissue Doppler Measures of E/E

Echo-Doppler evaluation of left ventricular diastolic function. Michel Slama Amiens France

Fluid bolus of 20% Albumin in post-cardiac surgical patient: a prospective observational study of effect duration

Respiratory stroke volume variation assessed by oesophageal Doppler monitoring predicts fluid responsiveness during laparoscopy

Articles in PresS. J Appl Physiol (September 29, 2005). doi: /japplphysiol

Rownak Jahan Tamanna 1, Rowshan Jahan 2, Abduz Zaher 3 and Abdul Kader Akhanda. 3 ORIGINAL ARTICLES

Left ventricular diastolic function and filling pressure in patients with dilated cardiomyopathy

Evalua&on)of)Le-)Ventricular)Diastolic) Dysfunc&on)by)Echocardiography:) Role)of)Ejec&on)Frac&on)

Introduction. Invasive Hemodynamic Monitoring. Determinants of Cardiovascular Function. Cardiovascular System. Hemodynamic Monitoring

Mechanical Ventilation & Cardiopulmonary Interactions: Clinical Application in Non- Conventional Circulations. Eric M. Graham, MD

DOPPLER HEMODYNAMICS (1) QUANTIFICATION OF PRESSURE GRADIENTS and INTRACARDIAC PRESSURES

Basic Approach to the Echocardiographic Evaluation of Ventricular Diastolic Function

PHYSIOLOGY MeQ'S (Morgan) All the following statements related to blood volume are correct except for: 5 A. Blood volume is about 5 litres. B.

Noninvasive assessment of left ventricular (LV)

(D) (E) (F) 6. The extrasystolic beat would produce (A) increased pulse pressure because contractility. is increased. increased

CATCH A WAVE.. INTRODUCTION NONINVASIVE HEMODYNAMIC MONITORING 4/12/2018

Cardiac Cycle MCQ. Professor of Cardiovascular Physiology. Cairo University 2007

Index of subjects. effect on ventricular tachycardia 30 treatment with 101, 116 boosterpump 80 Brockenbrough phenomenon 55, 125

Section 6 Intra Aortic Balloon Pump

Impedance Cardiography (ICG) Method, Technology and Validity

Hemodynamic Monitoring

Time Constants of Cardiac Function and Their Calculations

E/Ea is NOT an essential estimator of LV filling pressures

Adel Hasanin Ahmed 1

Cardiac Output Monitoring - 6

PRACTICE GUIDELINES: INTRA-ABDOMINAL HYPERTENSION/ABDOMINAL COMPARTMENT SYNDROME

How to Assess Diastolic Dysfunction?

Mechanics of Cath Lab Support Devices

HISTORY. Question: How do you interpret the patient s history? CHIEF COMPLAINT: Dyspnea of two days duration. PRESENT ILLNESS: 45-year-old man.

Appendix II: ECHOCARDIOGRAPHY ANALYSIS

Prof. Dr. Iman Riad Mohamed Abdel Aal

Left atrial function. Aliakbar Arvandi MD

Nothing to Disclose. Severe Pulmonary Hypertension

Positive end-expiratory pressure aggravates left ventricular diastolic relaxation further in patients with pre-existing relaxation abnormality

Cytoreductive Surgery and Hyperthermic Intraperitoneal Chemotherapy

ONLINE DATA SUPPLEMENT. Impact of Obstructive Sleep Apnea on Left Ventricular Mass and. Diastolic Function

Definition- study of blood flow Haemodynamic monitoring refers to monitoring of blood in the cardiovascular system Uses Is NB in the critically ill

Evaluation of Left Ventricular Diastolic Dysfunction by Doppler and 2D Speckle-tracking Imaging in Patients with Primary Pulmonary Hypertension

Elevated LV filling pressure is a major determinant of cardiac symptoms and

25. Fluid Management and Renal Function During a Laparoscopic Case Done Under CO 2 Pneumoperitoneum

Mechanics of Cath Lab Support Devices

Anaesthetic considerations for laparoscopic surgery in canines

Impedance Cardiography (ICG) Application of ICG in Intensive Care and Emergency

The abdominal compliance measurement to optimize laparoscopy. 2014

PROBLEM SET 2. Assigned: February 10, 2004 Due: February 19, 2004

Evaluation of the Effects of Elevated Intraabdominal. on the Respiratory Mechanics in Mechanically Ventilated Patients

HISTORY. Question: What category of heart disease is suggested by the fact that a murmur was heard at birth?

Non-Invasive Bed-Side Assessment of Pulmonary Vascular Resistance in Critically Ill Pediatric Patients with Acute Respiratory Distress Syndrome

An Integrated Approach to Study LV Diastolic Function

Journal of the American College of Cardiology Vol. 34, No. 2, by the American College of Cardiology ISSN /99/$20.

Review Article. Interactive Physiology in Critical Illness : Pulmonary and Cardiovascular Systems. Introduction

Management of Cardiogenic Shock. Dr Stephen Pettit, Consultant Cardiologist

The study of left ventricular diastolic function by Doppler echocardiography: the essential for the clinician

Pericardial Disease: Case Examples. Echo Fiesta 2017

THE RIGHT VENTRICLE IN PULMONARY HYPERTENSION R. DRAGU

Index. K Knobology, TTE artifact, image resolution, ultrasound, 14

Technique. Technique. Technique. Monitoring 1. Local anesthetic? Aseptic technique Hyper-extend (if radial)

Effects of mechanical ventilation on organ function. Masterclass ICU nurses

ICU treatment of the trauma patient. Intensive Care Training Program Radboud University Medical Centre Nijmegen

Hemodynamic Monitoring in Critically ill Patients in Arthur Simonnet, interne Tuteur : Pr. Raphaël Favory

Hemodynamic monitoring beyond cardiac output

Left Venticular Diastolic Dysfunction in Essential Hypertension

Hemodynamic Monitoring and Circulatory Assist Devices

The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the Edwards PreSep oximetry catheter

Mechanisms of heart failure with normal EF Arterial stiffness and ventricular-arterial coupling. What is the pathophysiology at presentation?

Ventriculo-arterial coupling and diastolic elastance. MasterclassIC Schiermonnikoog 2015

Journal of the American College of Cardiology Vol. 36, No. 5, by the American College of Cardiology ISSN /00/$20.

Comparison of automated and static pulse respiratory mechanics during supported ventilation

In patients with aortic dissection, expansion of the false

OT Exam 3, August 19, 2002 Page 1 of 6. Occupational Therapy Physiology, Summer Examination 3. August 19, 2002

Sepsis Wave II Webinar Series. Sepsis Reassessment

M. Hajahmadi Poorrafsanjani 1 & B. Rahimi Darabad 1

Haemodynamic, acid base and blood volume changes during prolonged low pressure pneumoperitoneum in rabbits

The right heart: the Cinderella of heart failure

Heart Pump and Cardiac Cycle. Faisal I. Mohammed, MD, PhD

Frederic J., Gerges MD. Ghassan E. Kanazi MD., Sama, I. Jabbour-Khoury MD. Review article from Journal of clinical anesthesia 2006.

Effect of physiological heart rate changes on left ventricular dimensions and mitral blood flow velocities in the normal fetus

Assessing the Impact on the Right Ventricle

Diastolic Function: What the Sonographer Needs to Know. Echocardiographic Assessment of Diastolic Function: Basic Concepts 2/8/2012

Squeeze, Squeeze, Squeeze: The Importance of Right Ventricular Function and PH

Jong-Won Ha*, Jeong-Ah Ahn, Jae-Yun Moon, Hye-Sun Suh, Seok-Min Kang, Se-Joong Rim, Yangsoo Jang, Namsik Chung, Won-Heum Shim, Seung-Yun Cho

The Cardiac Cycle Clive M. Baumgarten, Ph.D.

Diastolic Function Overview

Advanced imaging of the left atrium - strain, CT, 3D, MRI -

Tissue Doppler-Derived Myocardial Acceleration for Evaluation of Left Ventricular Diastolic Function

Καθετηριασμός δεξιάς κοιλίας. Σ. Χατζημιλτιάδης Καθηγητής Καρδιολογίας ΑΠΘ

Reduction of Intra-abdominal Hypertension Is Associated with Increase of Cardiac Output in Critically Ill Patients Undergoing Mechanical Ventilation

Radboud University Nijmegen Medical Centre Why measure cardiac output in critically ill children?

Diastolic Heart Failure

Hemodynamic Assessment. Assessment of Systolic Function Doppler Hemodynamics

Diastolic Function Assessment Practical Ways to Incorporate into Every Echo

Deceleration time of systolic pulmonary venous flow: a new clinical marker of left atrial pressure and compliance

BIPN100 F15 Human Physiol I (Kristan) Lecture 14 Cardiovascular control mechanisms p. 1

Journal of Anesthesia & Clinical

Relax and Learn At the Farm 2012

Disclosures. Afterload on the PV loop. RV Afterload THE PULMONARY VASCULATURE AND ASSESSMENT OF THE RIGHT VENTRICLE

A NONINVASIVE METHOD FOR CHARACTERIZING VENTRICULAR DIASTOLIC FILLING DYNAMICS

Right Heart Catheterization. Franz R. Eberli MD Chief of Cardiology Stadtspital Triemli, Zurich

Transcription:

British Journal of Anaesthesia 18 (2): 211 15 (212) Advance Access publication 8 December 211. doi:1.193/bja/aer382 Effect of intra-abdominal hypertension on left ventricular relaxation: a preliminary animal study Y. Mahjoub 1,2 *, E. Lorne 1,2, J. Maizel 2,3, G. Plantefève 4, Z. A. Massy 2,5, H. Dupont 1,2 and M. Slama 2,3 1 Medical and Surgical Intensive Care Unit, Department of Anaesthesia and Intensive Care, Amiens University Hospital, Amiens, France 2 INSERM Unit ERI-12 (EA 4292), Amiens, France 3 Medical Intensive Care Unit, Department of Nephrology, Amiens University Hospital, Amiens, France 4 Medical and Surgical Intensive Care Unit, Victor Dupouy Hospital, Argenteuil, France 5 Divison of Clinical Pharmacology, Clinical Research Centre, Amiens University Hospital and Jules Verne University of Picardy, France * Corresponding author. E-mail: mahjoub.yazine@chu-amiens.fr Editor s key points Raised intra-abdominal pressure can be life threatening in critically ill patients. In this study using rabbits, the effect of increasing abdominal pressure on diastolic function was measured. A clinically relevant increase in abdominal pressure impaired left ventricular relaxation. The mechanism requires further investigation. Background. In the intensive care unit, intra-abdominal hypertension (IAH) is a frequently encountered, life-threatening condition. The aim of this animal study was to evaluate the effect of IAH on left ventricular (LV) relaxation (i.e. the active phase of diastole). Methods. Seven male rabbits were anaesthetized before mechanical ventilation. A 2 mm Hg increase in intra-abdominal pressure (IAP) was then induced by intraperitoneal infusion of 1.5% glycine solution. Haemodynamic parameters were recorded and the relaxation time constant tau (considered to be the best index of left ventricle relaxation) was calculated. All haemodynamic measurements were recorded at baseline and then after induction of IAH. Results. A 2 mm Hg increase in IAP was not followed by a significant change in arterial pressure, but was associated with increases in central venous pressure (from 2 [22 to6] to 7 [22 to 12] mm Hg, P ¼.3), LV end-diastolic pressure (from 7 [6 8] to 15 [11 19] mm Hg, P ¼.4) and the relaxation time constant tau (from 16 [14 18] to 43 [34 52] ms, P ¼.48). Conclusions. In this animal study, a 2 mm Hg increase in IAP impaired LV relaxation. Further studies are necessary to identify the causes of this impairment. Keywords: abdominal compartment syndrome; diastolic function; haemodynamic; intraabdominal hypertension Accepted for publication: 7 October 211 Intra-abdominal hypertension (IAH) is frequently encountered in intensive care units (ICU) and can cause multiple organ failure. 12 The haemodynamic impairment is complex and only partially understood. 3 5 Several studies have described impairments in venous return, whereas others have reported increased systemic vascular resistance or right ventricular dysfunction. 3 5 However, no data are available concerning the potential impairment of left ventricular (LV) diastolic function by high intra-abdominal pressure (IAP). In the ICU, fluid infusion is the front-line therapy for patients with haemodynamic instability due to abdominal compartment syndrome. Nevertheless, in the event of LV diastolic dysfunction, fluid infusion could lead to pulmonary oedema. As increases in both systemic vascular resistance and right ventricular dysfunction could impair LV diastolic function, we hypothesized that the latter would be impaired by IAH. The aim of this preliminary animal study was to evaluate the effect of IAH on LV relaxation (the active, ATPdependent component of diastole 67 ). We therefore studied the effect of IAH on the relaxation time constant tau, which is considered to be the best index of LV relaxation. 6 8 Methods Animal preparation The experimental protocol was performed in seven male New Zealand white rabbits after approval by an institutional animal care committee. After an overnight fasting with unrestricted access to water, s.c. premedication with ketamine (25 mg kg 21 )was performed. Then, the animals were anaesthetized by continuous infusion of midazolam (1 mg kg 21 h 21 ) and sufentanil (1 mg kg 21 h 21 ) through the marginal vein of the right ear. Adequacy of anaesthesia was evaluated by the lack of response to an ear pinch. Tracheostomy was performed to allow insertion of a tracheal cannula. The animals were then administered pancuronium bromide (2 mg 21 kg 21 h 21 ) and were ventilated in a volume-controlled mode with an inspiratory oxygen fraction of 1. and a tidal volume of 1 ml kg 21.We decided to ventilate the animals without positive end-expiratory pressure, in order to avoid this technique s potentially confounding effect on the volume status and on the right heart. The respiratory rate was adjusted (55 65 min 21 ) & The Author [211]. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com

BJA Mahjoub et al. to obtain a baseline arterial PCO 2 of 3 4 mm Hg. An airfilled balloon was placed in the oesophagus to monitor oesophageal pressure. A fluid-filled catheter was introduced into the femoral artery to measure blood pressure. The tip of this catheter was placed in the abdominal aorta, near to the renal arteries. The right common carotid artery was cannulated in the neck, in order to introduce a Millar Mikro-Tip catheter (Millar Instruments Inc., Houston, USA) into the LV. The position of the catheter tip was confirmed by observing the blood pressure profile. The right jugular vein was cannulated with a fluid-filled catheter, in order to measure central venous pressure (CVP). Body temperature was maintained at 38.5 398C with a heating pad. Two fluid-filled catheters were inserted directly into the peritoneum (one for monitoring IAP and the other for infusing 1.5% glycine solution). The first catheter was connected via rigid tubing to a mercury manometer and zeroed near the mid-axillary line. Measurements and calculations Blood pressure, CVP, plateau pressure, oesophageal pressure, IAP and LV pressure (LVP) were recorded. The maximum rate of LVP increase during isovolumic contraction (dlvp max /dt), an index of LV contractility, 9 and the LV relaxation time constant tau were calculated by the data acquisition system (emka TECHNOLOGIES France, Paris, France). The time constant tau was calculated by considering the exponential decline of LV pressure during isovolumic relaxation, according to the derivative method described by Weiss and colleagues 8 (Fig. 1). All measurements and calculations were made at the end of expiration. Study protocol Following instrumentation, a 1 h stabilization period was observed. The ventilation parameters were held constant throughout the study protocol. All haemodynamic data were recorded at baseline. The abdominal cavity was then filled with a (non-absorbable) glycine solution, in order to obtain a 2 mm Hg increase in IAP. After a further 1 h stabilization period, all haemodynamic data were again recorded. A stable blood sodium concentration was used as a guide to the absence of glycine absorption. 1 All pressure measurements were performed continuously and averaged over 1 consecutive cardiac cycles. Data from baseline and IAH (IAP ¼ baseline + 2 mm Hg) conditions were compared. Statistical analysis All results are expressed as the median [interquartile range] and (full range). A Wilcoxon rank-sum test was used to compare data. The threshold for statistical significance was set to P,.5. Results The animals median body weight was 348 [2978 3118] g and the median age was 72 [5 17] days. The baseline and IAH conditions did not differ significantly in terms of the heart rate or arterial pressure (Table 1). The plateau pressure increased significantly (from 23 [18 28] cm H 2 O at baseline to 34 [27 42] cm H 2 O with IAH; P ¼.4), whereas oesophageal pressure did not vary significantly (from 2.8 [1.5 4] cm H 2 O at baseline to 3.9 [2 4.5] cm H 2 O with IAH; P ¼.22). Significant increases in CVP and LV end-diastolic pressure (LVEDP) were also observed (Table 1). The relaxation time constant tau increased significantly with IAH (from 16 [13 19] at baseline to 43 [25 63] ms with IAH; P ¼.48). The value of dlvp max/ dt was lower with IAH, but the difference vs baseline was not statistically significant (Table 1). Discussion The present study s most important finding was the significant increase in the relaxation time constant tau with IAH. Isovolumic relaxation (the early phase of diastole) can be quantified by measuring LVP and calculating the peak instantaneous rate of LVP decline. Nevertheless, this index is highly dependent on the aortic pressure. Since the LVP decline is assumed to be exponential over time, dlvp/dt can be expressed as an exponential equation. 8 When the natural log of LVP is plotted vs time, a straight line is obtained. The slope of this linear relation is called A. The tau time constant can then be calculated and equals 21/A 8 (Fig. 1). Tau is considered to be the best index of relaxation and so an increase in this parameter will reflect impaired relaxation. 6 8 Here, the sharp observed increase in tau indicates that IAH impairs LV relaxation in this animal model. In two previous human studies, the effect of IAH on diastolic function was monitored with echocardiography. 11 12 Alfonsi and colleagues studied 15 patients during laparoscopic aortic surgery, whereas Russo and colleagues studied 1 patients during laparoscopic hysterectomy. 11 12 Using echocardiography, the researchers found that an increase in IAP decreased the E/A ratio for mitral flow 11 and the peak velocity of the E wave and increased the E wave deceleration time and the isovolumetric relaxation time. 11 Both groups concluded that LV diastolic function was impaired by IAH. However, the fact that the indices used in these studies are highly dependent on loading conditions 6 weakens the researchers conclusions. The mitral annulus diastolic peak velocity E (which can be investigated with Tissue Doppler Imaging) is less dependent on loading conditions and well correlated with tau, but it was not measured as an index of LV diastolic function in the two aforementioned studies. 13 Moreover, the two studies were performed in patients undergoing laparoscopic surgery and carbon dioxide insufflation. This gas can induce its own circulatory effects. 14 In an animal study, Mann and colleagues have demonstrated that insufflation of carbon dioxide (but not argon) to an IAP of 15 mm Hg induced vasopressin release and thus an increase in systemic vascular resistance. 14 We avoided these limitations by filling the peritoneum with fluid and using a gold-standard method to evaluate LV relaxation. In the present study, the observed impairment in ventricular relaxation may have had several causes. First, relaxation 212

Effect of intra-abdominal hypertension on left ventricular relaxation BJA A Baseline B Baseline +2 mm Hg LVP LVP dlvp max /dt dlvp max /dt dlvp/dt dlvp/dt dlvp min /dt dlvp min /dt AWP AWP A 1 B 1 1 LVP (mm Hg) 8 6 4 2 LVP=e.659 t + 3.6843 LVP (mm Hg) 1 9 8 7 6 5 4 3 2 1 LVP=e.329 t + 4.6691 A 2 5 4 In (LVP) =.659 t + 3.6843 t = 1/.659 = 16 ms B 2 3 2 1 In (LVP) In (LVP) 5 4 3 2 1 In (LVP) =.329 t + 4.6691 = 1/.329 = 31 ms Fig 1 The recorded values for left ventricular pressure (LVP), the derivative of LVP vs time (dlvp/dt) and the airway pressure (AWP). An example of calculation of tau at baseline and after having increased the intra-abdominal pressure (IAP) by 2 mm Hg is given for a single representative animal. A single heartbeat at end expiration was analysed. The decrease of LVP from dlvp min/ dt is an exponential function against time: LVP ¼ e At+B (graphs A 1 and B 1 ). When the natural log of LVP is plotted vs time, a linear relationship ln (LVP) ¼ At + B is found (graphs A 2 and B 2 ). A is the slope of this straight line. The tau relaxation time constant characterizes the pressure decrease phase and is equivalent to 1/2A. In this example, we can see that tau increases from 16 ms at baseline to 31 ms with a 2 mm Hg increase in IAP. is an energy-consuming process and is thus affected by myocardial ischaemia. 6 The potential presence of IAH-induced heart ischaemia requires further investigation. Secondly, contraction and relaxation are intimately coupled and so a change in the former could affect the latter. 6 7 The peak rate of increase in ventricular pressure during systole (dlvp max /dt) is markedly influenced by acute changes in contractility but does not depend on afterload changes. 9 The decrease in dlvp max /dt observed in our animal model was not significant; this was probably due to the small sample size. It is therefore difficult to draw reliable conclusions concerning impaired contractility. Nevertheless, some animal and human studies have reported IAH-induced LV systolic dysfunction. 5 However, other animal and human 15 16 studies did not show evidence of impaired contractility. Thirdly, an acute increase in LV afterload could lead to impaired relaxation. Several studies have shown that IAH results in elevated circulating levels of renin, aldosterone, 213

BJA Mahjoub et al. Table 1 Haemodynamic parameters and airway pressures at baseline and with intra-abdominal hypertension (IAH). Results are expressed as the median [interquartile range] and (full range). HR, heart rate; MAP, SAP and DAP, mean, systolic and diastolic arterial pressure; IAP, intra-abdominal pressure; dlvp max /dt, maximum rate of increase in left ventricular pressure during isovolumic contraction; LVEDP, left ventricular end-diastolic pressure; CVP, central venous pressure; Tau, relaxation time constant Baseline IAH (baseline 1 2 mm Hg) P-value HR (bpm) 22 [152 252] (15 255) 166 [116 216] (115 22).6 MAP (mm Hg) 6 [45 75] (44 76) 5 [38 67] (36 7).2 SAP (mm Hg) 72 [61 83] (6 85) 83 [6 13] (58 15).15 DAP (mm Hg) 48 [43 52] (35 6) 41 [3 56] (3 58).45 dlvp max /dt (mm Hg s 21 ) 359 [3463 3717] (345 375) 2111 [211 2211] (22 2225).14 Tau (ms) 16 [14 18] (13 19) 43 [34 52] (31 55).48 LVEDP (mm Hg) 7 [6 8] (5 9) 15 [11 19] (1 2).4 CVP (mm Hg) 2 [22 to6](21 to7) 7[22 to 12] (21 to 13).3 Plateau pressure (cm H 2 O) 23 [18 28] (17 29) 34 [27 42] (25 43).4 Oesophageal pressure (cm H 2 O) 2.8 [1.5 4] (1 5) 3.9 [2 4.5] (1.5 5).22 and catecholamine and thus increases systemic vascular resistance. 4 5 11 14 15 Fourthly, an acute increase in right ventricular afterload could also impair LV relaxation. 5 11 17 The fact that the observed increase in plateau pressure was not accompanied by a change in tidal volume suggests that lung and/or chest wall compliance was lower during IAH. 11 17 A decrease in lung compliance caused by an upward displacement of the diaphragm could have increased the right ventricular afterload. 51117 We also found that oesophageal pressure at end-expiration remained stable whilst CVP and LVEDP increased with IAH. This increase of left and right filling pressures (CVP and LVEDP) was probably not due to pressure transmission but to blood shift from the abdomen to the thorax. These results are in line with those of an animal study with the same IAP. 17 However, other researchers have found an increase in oesophageal pressure, albeit at higher IAP levels 18 19 or in a lung injury context. 17 In the present study, we increased the IAP by 2 mm Hg. We did not measure the exact baseline IAP which may have created some bias. However, previous studies showed that the baseline value of IAP in rabbits is close to zero (between and 2 mm Hg) and lower than that in humans because the rabbit s abdominal compliance is higher. 2 We considered the baseline IAP to be zero and added 2 mm Hg because abdominal compartment syndrome (a lifethreatening condition) was defined by the World Society of Abdominal Compartment Syndrome Consensus Conference as a sustained IAP. 2 mm Hg that is associated with new organ dysfunction/failure. 2 One of the limitations of the present study relates to the anatomical differences between rabbits and humans. As a quadruped, the rabbit has less developed anterior muscles, which leads to higher abdominal compliance. 2 Moreover, the rabbit s anatomical proportions are close to those of young human infants (i.e. a small thorax and a large abdomen) whilst larger mammals, like pigs, are more close to adults. Hence, some authors emphasize the value of the rabbit model in investigating the physiological effects of IAP on infants. 21 Despite important differences between human and rabbit heart regarding the position in the thorax, the percentage of body weight (higher for humans) or heart rate, 22 the rabbit as a model to study human heart function has several advantages over other mammals because the composition of sarcommeric proteins and the sarcolemmic reticulum contribution to calcium elimination are similar. 23 Another important limitation is the lack of mechanistic evidence. In fact, this study should be considered as a preliminary study that enabled the formulation of hypotheses for investigation in further studies using right heart catheterization or Doppler echocardiographic examination. Nevertheless, physicians who care for patients with IAH must always bear in mind that these patients have impaired LV diastolic function. Indeed, fluid therapy the front-line therapy in patients with shock and IAH should be administered with care so as to avoid possible harmful effects on lung function. In conclusion, a 2 mm Hg increase in IAP impaired LV relaxation in this animal model of IAH. Further studies are required to investigate the mechanism of the observed impairment in LV relaxation. Declaration of interest None declared. Funding This work was supported by institutional funding only (INSERM and Jules Verne University of Picardy). References 1 Malbrain ML, Chiumello D, Pelosi P, et al. Incidence and prognosis of abdominal hypertension in a mixed population of critically ill patients: a multiple-center epidemiological study. Crit Care Med 25; 33: 315 22 2 Malbrain ML, Cheatham ML, Kirpatrick A, et al. Results from the international conference of experts on intra-abdominal 214

Effect of intra-abdominal hypertension on left ventricular relaxation BJA hypertension and abdominal compartment syndrome. I. Definitions. Intensive Care Med 26; 32: 1722 32 3 Cheatham ML, Malbrain ML. Cardiovascular implications of abdominal compartment syndrome. Acta Clin Belg Suppl 27; 32: 68 112 4 Mahjoub Y, Plantefeve G. Cardiac ultrasound and abdominal compartment syndrome. Acta Clin Belg Suppl 27; 62: 183 9 5 Kitano Y, Takata M, Sasaki N, Zhang Q, Yamamoto S, Miyasaka K. Influence of increased abdominal pressure on steady-state cardiac performance. J Appl Physiol 1999; 86: 1651 6 6 Nishimura RA, Tajik AJ. Evaluation of diastolic filling of left ventricle in health and disease: Doppler echocardiography is the clinician s Rosetta stone. J Am Coll Cardiol 1997; 3: 8 18 7 Zile MR, Brutsaert DL. New concepts in diastolic dysfunction and diastolic heart failure: Part I. Circulation 1997; 15: 1387 93 8 Weiss JL, Fredericksen JW, Weisfeldt ML. Hemodynamic determinants of the time course of fall in canine left ventricular pressure. J Clin Invest 1976; 58: 83 95 9 Gleason WL, Braunwald E. Studies on the first derivative of the ventricular pressure pulse in man. J Clin Invest 1962; 41: 8 91 1 Collins JW, Macdermott S, Bradbrook RA, Drake B, Keeley FX, Timoney AG. The effect of the choice of irrigation fluid on cardiac stress during transurethral resection of the prostate: a comparison between 1.5% glycine and 5% glucose. JUrol27; 177: 1369 73 11 Alfonsi P, Vieillard-Baron A, Coggia M, et al. Cardiac function during intraperitoneal CO 2 insufflation for aortic surgery: a transoesophageal echocardiographic study. Anesth Analg 26; 12: 134 1 12 Russo A, Marana E, Viviani D, et al. Diastolic function: the influence of pneumoperitoneum and Trendelenburg positioning during laparoscopic hysterectomy. Eur J Anaesthesiol 29; 26: 923 7 13 Nagueh SF, Middleton KJ, Kopelen HA, Zoghbi WA, Quinones MA. Doppler tissue imaging: a noninvasive technique for evaluation of left ventricular relaxation and estimation of filling pressures. JAm Coll Cardiol 1997; 3: 1527 33 14 Mann C, Boccara G, Pouzeratte Y, et al. The relationship among carbon dioxide pneumoperitoneum, vasopressin release, and hemodynamic changes. Anesth Analg 1999; 89: 278 83 15 Marathe US, Lilly RE, Silvestry SC, et al. Alterations in hemodynamics and left ventricular contractility during carbon dioxide pneumoperitoneum. Surg Endosc 1996; 1: 974 8 16 Cunningham AJ, Turner J, Rosenbaum S, Rafferty T. Transoesophageal echocardiographic assessment of haemodynamic function during laparoscopic cholecystectomy. Br J Anaesth 1993; 7: 621 5 17 Quintel M, Pelosi P, Caironi P, et al. An increase of abdominal pressure increases pulmonary edema in oleic acid-induced lung injury. Am J Respir Crit Care Med 24; 169: 534 41 18 Duperret S, Lhuillier F, Piriou V, et al. Increased intra-abdominal pressure affects respiratory variations in arterial pressure in normovolaemic mechanically ventilated healthy pigs. Intensive Care Med 27; 33: 163 71 19 Valenza F, Chevallard G, Porro GA, Gattinoni L. Static and dynamic components of oesophageal and central venous pressure during intra-abdominal hypertension. Crit Care Med 27; 35: 1575 81 2 Yoshino O, Quail A, Oldmeadow C, Balogh ZJ. The interpretation of intra-abdominal pressures from animal models: The rabbit to human example. Injury Advanced Access published on 16 May 211, doi:1.116/j.injury.211.4.11 21 Sümpelmann R, Schuerholz T, Marx G, et al. Haemodynamic, acid base and blood volume changes during prolonged low pressure pneumoperitoneum in rabbits. Br J Anaesth 26; 96: 563 8 22 Hew KW, Keller KA. Postnatal anatomical and functional development of the heart: a species comparison. Birth Defects Res B Dev Reprod Toxicol 23; 68: 39 2 23 Loughrey CM, Smith GL, MacEarchern KE. Comparison of Ca 2+ release and uptake characteristics of the sarcoplasmic reticulum in isolated horse and rabbit cardiomyocytes. Am J Physiol Heart Circ Physiol 24; 287: H1149 59 215