Kit Components Product # EP42720 (24 preps) MDx 2X PCR Master Mix 350 µl Cryptococcus neoformans Primer Mix 70 µl Cryptococcus neoformans Positive

Similar documents
Product # Kit Components

Cytomegalovirus (CMV) End-Point PCR Kit Product# EP36300

Norgen s HIV proviral DNA PCR Kit was developed and validated to be used with the following PCR instruments: Qiagen Rotor-Gene Q BioRad icycler

Norgen s HIV Proviral DNA PCR Kit was developed and validated to be used with the following PCR instruments: Qiagen Rotor-Gene Q BioRad T1000 Cycler

Urine - Based XMRV RT-PCR Detection Kit Product # 34700

Urine - Based CMV PCR Detection Kit Product # 36300

Sputum DNA Collection, Preservation and Isolation Kit 50 Individual Devices

Urine Exosome RNA Isolation Kit Product #47200

AmoyDx TM BRAF V600E Mutation Detection Kit

Pneumocystis Carinii Real Time PCR Kit. For In Vitro Diagnostic Use Only User Manual

RealLine Mycoplasma genitalium Str-Format

ABIOpure TM Viral (version 2.0)

Leukemia BCR-ABL Fusion Gene Real Time RT-PCR Kit

Instructions for Use. RealStar Influenza Screen & Type RT-PCR Kit /2017 EN

Product Contents. 1 Specifications 1 Product Description. 2 Buffer Preparation... 3 Protocol. 3 Ordering Information 4

Pinpoint Slide RNA Isolation System II Catalog No. R1007

altona RealStar Instructions for Use RealStar CMV PCR Kit /2017 EN DIAGNOSTICS

Instructions for Use. RealStar Influenza S&T RT-PCR Kit /2017 EN

XTRAKT FFPE Kit / Manual

Midi Plant Genomic DNA Purification Kit

HIV-1 Viral Load Real Time (RG)

Product Contents. 1 Specifications 1 Product Description. 2 Buffer Preparation... 3 Protocol. 3 Ordering Information 4 Related Products..

RealLine HIV qualitative Str-Format

For in vitro Veterinary Diagnostics only. Kylt Rotavirus A. Real-Time RT-PCR Detection.

MALDI Sepsityper Kit

RealLine HCV Qualitative Str-Format

1. Intended Use New Influenza A virus real time RT-PCR Panel is used for the detection of universal influenza A virus, universal swine Influenza A vir

RealLine HBV / HCV / HIV Str-Format

RealLine HIV quantitative Str-Format

ExiPrep TM Viral DNA/ RNA Kit

For Research Use Only Ver

Storage: Logix Smart Zika Virus Master Mix and Logix Smart Zika Virus Positive Control must be stored at -20 ⁰C and can last up to 60 days.

Single Cell Quantitative Polymer Chain Reaction (sc-qpcr)

HDV Real-TM. Handbook

XCF TM COMPLETE Exosome and cfdna Isolation Kit (for Serum & Plasma)

For Research Use Only Ver

by nexttec TM 1 -Step

AquaPreserve DNA/RNA/Protein Order # Preservation and Extraction Kit 8001MT, 8060MT

INSTRUCTION MANUAL. RNA Clean & Concentrator -5 Catalog Nos. R1015 & R1016. Highlights. Contents

EXOSOMES & MICROVESICLES

EXO-DNAc Circulating and EV-associated DNA extraction kit

EXO-DNA Circulating and EV-associated DNA extraction kit

Validation Report: VERSA Mini PCR Workstation Reverse Transcription of Avian Flu RNA and Amplification of cdna & Detection of H5N1

Pneumocystis jirovecii (carinii) Real-TM

ExoQuick Exosome Isolation and RNA Purification Kits

CMV FEP ALA For nucleic acid amplification of CMV DNA and Fluorescence detection with End Point analysis (FEP) on Aladin (Sacace)

Product Manual. Omni-Array Sense Strand mrna Amplification Kit, 2 ng to 100 ng Version Catalog No.: Reactions

E.Z.N.A. SQ Blood DNA Kit II. Table of Contents

Roche Molecular Biochemicals Application Note No. HP 1/1999

For Research Use Only Ver

AmpliX HBV Quantitative

For Research Use Only Ver

Insulin Aspart ELISA Kit

HBV Real-TM Quant Handbook

altona DIAGNOSTICS altona DIAGNOSTICS RealStar CMV PCR Kit 1.0 always a drop ahead. 11/2012

For Research Use Only Ver

EPIGENTEK. EpiQuik Total Histone Extraction Kit. Base Catalog # OP-0006 PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE

ExiPrep Plus Viral DNA/RNA Kit User s Guide ExiPrep Plus Viral DNA/RNA Kit ExiPrep Plus Viral DNA Kit ExiPrep Plus Viral RNA Kit

Bioneer Corporation 8-11,Munpyeongseo-ro, Daedeok-gu, Daejeon 34302, Republic of Korea Tel: Fax:

Microsart Calibration Reagent

Mitochondrial DNA Isolation Kit

Product Contents... 1 Specifications... 1 Product Description... 2 Buffer Preparation... 3 Protocol Appendix... 5 Ordering Information...

MolecularMD. One-Step qrt-pcr BCR-ABL Kit. Product Description and User Manual. For Quantitative RT-PCR Analysis of BCR-ABL. Contact Us.

Hepatitis B Virus Genemer

Vitamin A-E Serum HPLC Analysis Kit

For Research Use Only Ver

WHO Prequalification of Diagnostics Programme PUBLIC REPORT. Product: VERSANT HIV-1 RNA 1.0 Assay (kpcr) Number: PQDx

HDV Real-TM Quant Handbook

HIV-1 Genemer Detection Kit Ready to Use Amplification Kit for HIV-1 Specific DNA Fragment Analysis

Nuclear Extraction Kit

PKU (Phenylketonuria) Serum HPLC Analysis Kit User Manual

altona RealStar Instructions for Use RealStar Influenza Screen & Type RT-PCR Kit /2017 EN DIAGNOSTICS

Manual innuprep DNA/RNA Virus PLUS Kit - KFFLX

Exosome ELISA Complete Kits

Real Time Kit. Pneumocystis jirovecii (carinii) Real-TM Handbook. for the detection of Pneumocystis jirovecii (carinii) in biological materials

For Research Use Only Ver

ab Nuclear Extract Kit

Human Rotavirus B. Non structural protein 5 (NSP5) 150 tests. Quantification of Human Rotavirus B genomes Advanced kit handbook HB10.01.

Cladosporium_spp genesig Advanced Kit

ab HIV-1 Protease Inhibitor Screening Kit (Fluorometric)

Human Rotavirus A. genesig Advanced Kit. Non structural protein 5 (NSP5) 150 tests. Primerdesign Ltd. For general laboratory and research use only

RealLine HCV quantitative Str-Format

For purification of viral DNA and RNA from a wide range of sample materials

Cladosporium_spp genesig Standard Kit

Handbook. Influenza A H1N1 & H3N2 Real-TM. Real Time Amplification test for the detection of Influenza A H1N1 and H3N2 viruses

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual

Phosphate buffered saline (PBS) for washing the cells TE buffer (nuclease-free) ph 7.5 for use with the PrimePCR Reverse Transcription Control Assay

Human Rotavirus A. genesig Standard Kit. Non structural protein 5 (NSP5) 150 tests. Primerdesign Ltd. For general laboratory and research use only

Human influenza A virus subtype (H3)

Abbott RealTime IDH2. For Infomation Only - Not a Controlled Copy /R1 08N /R1 08N82-090

For Research Use Only Ver

Retro-X qrt-pcr Titration Kit User Manual

virotype Influenza A RT-PCR Kit Handbook

altona RealStar Instructions for Use RealStar CMV PCR Kit /2017 EN DIAGNOSTICS

ab Mammalian Cell Lysis Buffer 5X

Exosome ELISA Complete Kits

Transcription:

3430 Schmon Parkway Thorold, ON, Canada L2V 4Y6 Phone: 866-667-4362 (905) 227-8848 Fax: (905) 227-1061 Email: techsupport@norgenbiotek.com Cryptococcus neoformans End-Point PCR Kit Product# EP42720 Product Insert Intended Use Norgen s Cryptococcus neoformans End-Point PCR Kit is designed for the detection of Cryptococcus neoformans DNA based on the use of end-point PCR technology. This kit is designed for research use only and not for use in diagnostic procedures. Background Information Cryptococcus neoformans is an encapsulated yeast. Infection with C. neoformans is known as cryptococcosis and is the cause of the most common life-threatening meningitis in patients with weakened immune systems, particularly in advanced HIV/AIDS. C. neoformans is commonly found in soil throughout the world. Human infection of C. neoformans occurs via inhalation of aerosolized spores. From the lungs, C. neoformans is spread hematogenously to the Central Nervous System (CNS), resulting in meningoencephalitis. Although the availability of antiretroviral therapy in the developed world has reduced the incidents of cryptococcosis, it is still a major problem in developing countries and is one of the leading causes of death in patients with HIV/AIDS. In fact, one of the major challenges in treating cryptococcosis is that many patients with cryptococcal CNS disease are asymptomatic in terms of cryptococcal pneumonia, making it difficult for early detection. Product Description Norgen s Cryptococcus neoformans End-Point PCR Kit is designed for the detection of Cryptococcus neoformans specific DNA based on the use of end-point PCR technology. This kit is designed for research use only and not for use in diagnostic procedures. The kit includes Master Mix and primers for the specific amplification of a 278 nucleotide region of the Cryptococcus neoformans genome, as well as a positive control and a negative control to confirm the integrity of the kit reagents. In addition, the kit contains loading dye and a DNA ladder to facilitate analysis of the results. The detection of Cryptococcus neoformans specific DNA is based on end-point PCR technology, utilizing polymerase chain reaction (PCR) for the amplification of specific Cryptococcus neoformans DNA sequences. For analysis of the PCR data, the PCR reaction is loaded on an agarose DNA gel along with the provided DNA ladder for qualitative analysis. Norgen s Cryptococcus neoformans End-Point PCR Kit was developed and validated to be used with the following PCR instruments: Qiagen Rotor-Gene Q BioRad CFX96 Touch Real-Time PCR Detection System Kit Components Component Product # EP42720 (24 preps) MDx 2X PCR Master Mix 350 µl Cryptococcus neoformans Primer Mix 70 µl Cryptococcus neoformans Positive 50 µl C Nuclease-Free t l Water 1.25 ml Loading Dye 100 µl DNA Ladder 100 µl Product Insert 1 1

Storage Conditions and Product Stability All kit components should be stored at -20 C upon arrival Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots. All reagents can be stored for 1 year at -20 C without showing any reduction in performance. o Customer-Supplied Reagents and Equipment Appropriate End-point PCR Instrument DNA Purification Kit o The kit is compatible with all DNA purification kits that yield high quality, inhibitorfree DNA Recommended Purification Kit: Norgen s Blood DNA Isolation Mini Kit (Cat. 46300, 46380) Disposable powder-free gloves Benchtop microcentrifuge Micropipettors Sterile pipette tips with filters PCR tubes Vortex mixer Agarose gel electrophoresis apparatus UV transilluminator with suitable gel documentation system PCR reaction preparation station (Optional) Quality Control In accordance with Norgen s ISO 9001 and ISO 13485-certified Quality Management System, each lot of Norgen s Cryptococcus neoformans End-Point PCR Kit is tested against predetermined specifications to ensure consistent product quality. Warnings and Precautions Norgen s Cryptococcus neoformans End-Point PCR Kit is intended for research purposes only. It is not intended for diagnostic use. Follow universal precautions. All specimens should be considered as potentially infectious and handled accordingly. Ensure that a suitable lab coat, disposable gloves and protective goggles are worn when handling specimens and kit reagents. Use sterile pipette tips with filters. Use proper pipetting techniques and maintain the same pipetting pattern throughout the procedure to ensure optimal and reproducible values. As contamination of specimens or reagents can produce erroneous results, it is essential to use aseptic techniques. Pipette and handle reagents carefully to avoid mixing of the samples. Do not use supplies and equipment across the dedicated areas of i) specimen extraction, ii) reaction set-up and iii) amplification/detection. No cross-movement should be allowed between the different areas. Personal protective equipment, such as laboratory coats and disposable gloves, should be area specific. Store and extract positive material (specimens, controls and amplicons) separately from all other reagents and add it to the reaction mix in a spatially separated facility. 2

Dispose of unused kit reagents and specimens according to local, provincial or federal regulations. Do not substitute or mix reagents from different kit lots or from other manufacturers. Do not use components of the kit that have been stored for more than 1 year. The presence of PCR inhibitors may cause false negative or invalid results. Potential mutations within the target regions of the Cryptococcus neoformans genome covered by the primers in this kit may result in failure to detect the presence of the pathogen. Good laboratory practice is essential for the proper performance of this kit. Ensure that the purity of the kit and reactions is maintained at all times, and closely monitor all reagents for contamination. Do not use any reagents that appear to be contaminated. Ensure that appropriate specimen collection, transport, storage and processing techniques are followed for optimal performance of this test. Instructions for Use A. Sample Preparation Purified DNA is the starting material for Norgen s Cryptococcus neoformans End-Point PCR Kit. The quality of the DNA template will have a major impact on the performance of the Cryptococcus neoformans detection test. The user must ensure that the method used for DNA purification is compatible with end-point RT-PCR. We recommend the use of Norgen s Blood DNA Isolation Mini Kit (Cat. 46300, 46380). Norgen s Blood DNA Isolation Mini Kit has been fully validated with Norgen s Cryptococcus neoformans End-Point PCR Kit. If using a different spin column based sample preparation procedure that includes ethanol-based wash buffers is used, a column drying step consisting of centrifugation for 3 minutes at 20,000 x g (~14,000 RPM), using a new collection tube, is highly recommended prior to the elution of the DNA. This will help to prevent the carry-over of any ethanol into the purified DNA, as ethanol is known to be a strong inhibitor of PCR. Ensure that any traces of ethanol from the sample preparation steps are eliminated prior to the elution of the DNA. B. PCR Assay Preparation Notes: Before use, suitable amounts of all PCR components should be completely thawed at room temperature, mixed by gentle vortexing or by pipetting, and centrifuged briefly. Work quickly on ice. The amount of MDx 2X PCR Master Mix provided is enough for up to 32 PCR reactions (24 sample PCR, 4 positive control PCR and 4 no template control PCR). For every PCR run, one reaction containing Cryptococcus neoformans Positive Control and one reaction as no template control must be included for proper interpretation of results. The recommended minimum number of DNA samples tested per PCR run is 6. To avoid any contamination while preparing the PCR assay, follow the order outlined in Tables 1, 2 and 3 below to prepare the Negative Control, Detection Assay and Positive Control: 1. Prepare the PCR Negative Control (Table 1) 2. Prepare the PCR Cryptococcus neoformans Assay (Table 2) 3. Prepare the PCR Positive Control (Table 3) To further avoid contamination, add the components to the PCR tubes in the order shown in the tables below (ie: 1) Nuclease-free water; 2) Master Mix; 3) Primer Mix; and 4) the Sample DNA or Positive Control). 3

1. For each PCR set, prepare one no template control PCR as shown in Table 1 below: Table 1. PCR Negative Control Preparation PCR Components Volume Per PCR Reaction Nuclease-Free Water 8 µl MDx 2X PCR Master Mix 10 µl Cryptococcus neoformans Primer Mix 2 µl Total Volume 20 µl 2. Prepare the PCR reaction for sample detection as shown in Table 2 below. The recommended amount of sample DNA to be used is 2.5 μl. However, a volume between 1 and 5 μl of sample DNA may be used as template. Adjust the final volume of the PCR reaction to 20 μl using the Nuclease-Free Water provided. Table 2. PCR Cryptococcus neoformans Assay Preparation PCR Components Volume Per PCR Reaction Nuclease-Free Water 5.5 µl MDx 2X PCR Master Mix 10 µl Cryptococcus neoformans Primer Mix 2 µl Sample DNA 2.5 µl Total Volume 20 µl 3. For each PCR set, prepare one positive control PCR as shown in Table 3 below: Table 3. PCR Positive Control Preparation PCR Components Volume Per PCR Reaction MDx 2X PCR Master Mix 10 µl Cryptococcus neoformans Primer Mix 2 µl Cryptococcus neoformans Positive Control (PosC) 8 µl Total Volume 20 µl 4

C. Cryptococcus neoformans PCR Assay Programming 1. Program the thermocylcer according to the program shown in Table 4 below. 2. Run one step RT-PCR. Table 4. Cryptococcus neoformans Assay Program PCR Cycle Step Temperature Duration Cycle 1 Step 1 95 o C 3 min Step 1 94 o C 15 sec Cycle 2 (40x) Step 2 60 o C 30 sec Step 3 72 o C 45 sec Cycle 3 Step 1 72 o C 5 min Cycle 4 Step 1 4 o C D. Cryptococcus neoformans PCR Assay Interpretation For the analysis of the PCR data, the entire 20 µl PCR reaction should be loaded on a 1X TAE 1.4 % Agarose DNA gel along with 10 µl of Norgen s DNA Ladder (provided). The PCR products should be resolved on the 1X TAE, 1.4 % Agarose gel at 150V for 30 minutes (Gel running time will vary depending on an electrophoresis apparatus). Table 5. Interpretation of Assay Results Input Type Target amplification Interpretation Cryptococcus neoformans Target Band (278 bp) PCR control Band (150 bp) Positive Control Yes Yes Valid Positive Control Yes No Valid Negative Control No Yes Valid Sample Yes Yes Positive Sample No Yes Negative Sample No No PCR inhibition Sample Yes No Positive For results obtained that are not covered in Table 5 above, please refer to the Frequently Asked Questions. 5

Figure 1: A representative 1X TAE, 1.4 % agarose gel showing the amplification of Cryptococcus neoformans at different concentrations. The size of the Cryptococcus neoformans target amplicon corresponds to the 278 bp band represented by the provided DNA Marker (M). E. Cryptococcus neoformans PCR Assay Specificity The specificity of Norgen s Cryptococcus neoformans End-Point PCR Kit is first and foremost ensured by the selection of the Cryptococcus neoformans-specific primers, as well as the selection of stringent reaction conditions. The Cryptococcus neoformans primers were checked for possible homologies to all microorganisms in GenBank published sequences by sequence comparison analysis. Frequently Asked Questions 1. How many samples should be included per PCR run? Norgen s Cryptococcus neoformans End-Point PCR Kit is designed to test 24 samples. For every 6 samples, a non-template control (Nuclease Free Water) and a Positive Control must be included. It is preferable to collect and test 6 samples at a time. 2. How should it be interpreted if in negative control the Cryptococcus neoformans PCR control and the Cryptococcus neoformans target showed amplification in a sample? The assay has to be repeated. It could happen when there is carryover contamination. 3. How should it be interpreted if only the Cryptococcus neoformans target was amplified in a sample? The sample tested should be considered as Cryptococcus neoformans positive. At high Cryptococcus neoformans input, the Cryptococcus neoformans amplicon will be predominant and thus the Cryptococcus neoformans PCR control may not amplify as they compete for PCR resources. 6

Related Products Product # Cryptococcus neoformans Primer and Control Set - 100 Reactions EP42710 Cryptococcus neoformans TaqMan PCR Kit - 24 Reactions TM42720 Cryptococcus neoformans TaqMan Probe/Primer and Control Set - 100 Reactions TM42710 Blood DNA Isolation Mini Kit 46300, 46380 Technical Support Contact our Technical Support Team between the hours of 8:30 and 5:30 (Eastern Standard Time) at (905) 227-8848 or Toll Free at 1-866-667-4362. Technical support can also be obtained from our website (www.norgenbiotek.com) or through email at techsupport@norgenbiotek.com. Product Use Restriction Norgen s Cryptococcus neoformans End-Point PCR Kit is designed for the detection of Cryptococcus neoformans specific DNA based on the use of end-point PCR technology. This kit is designed for research use only and not for use in diagnostic procedures. Norgen s Cryptococcus neoformans End-Point PCR Kit is intended for use by professional users such as technicians and biologists experienced and trained in molecular biological techniques including PCR. Good laboratory practice is essential for the proper performance of this kit. Ensure that the purity of the kit and reactions is maintained at all times, and closely monitor all reagents for contamination. Do not use any reagents that appear to be contaminated. Ensure that appropriate specimen collection, transport, storage and processing techniques are followed for optimal performance of this test. The presence of PCR inhibitors may cause false negative or invalid results. Potential mutations within the target regions of the Cryptococcus neoformans genome covered by the primers in this kit may result in failure to detect the presence of the pathogen. The respective user is liable for any and all damages resulting from application of Norgen s Cryptococcus neoformans End-Point PCR Kit for use deviating from the intended use as specified in the user manual. All products sold by Norgen Biotek are subjected to extensive quality control procedures and are warranted to perform as described when used correctly. Any problems should be reported immediately. The kit contents are for laboratory use only, and they must be stored in the laboratory and must not be used for purposes other than intended. The kit contents are unfit for consumption. Norgen Biotek Corp. 3430 Schmon Parkway, Thorold, ON Canada L2V 4Y6 Phone: (905) 227-8848 Fax: (905) 227-1061 Toll Free in North America: 1-866-667-4362 2018 Norgen Biotek Corp. PITM42720-1 7