Kinematic vs. mechanical alignment: What is the difference?

Similar documents
An In Vivo Study of the Effect of Distal Femoral Resection on Passive Knee Extension

Kinematically Versus Mechanically Aligned Total Knee Arthroplasty

Does A Kinematically Aligned Total Knee Arthroplasty Restore Function Without Failure Regardless of Alignment Category?

Does Malrotation of the Tibial and Femoral Components Compromise Function in Kinematically. Arthroplasty?

Simulation of Total Knee Arthroplasty in 5 or 7 Valgus: A Study of Gap Imbalances and Changes in Limb and Knee Alignments From Native

Stephen M. Howell Justin Chen Maury L. Hull

Masterclass. Tips and tricks for a successful outcome. E. Verhaven, M. Thaeter. September 15th, 2012, Brussels

TKA Gap Planning. Supporting healthcare professionals

PRE & POST OPERATIVE RADIOLOGICAL ASSESSMENT IN TOTAL KNEE REPLACEMENT. Dr. Divya Rani K 2 nd Year Resident Dept. of Radiology

CONTRIBUTING SURGEON. Barry Waldman, MD Director, Center for Joint Preservation and Replacement Sinai Hospital of Baltimore Baltimore, MD

Bilateral total knee arthroplasty: One mobile-bearing and one fixed-bearing

Comparison of high-flex and conventional implants for bilateral total knee arthroplasty

STIFFNESS AFTER TKA PRE, PER AND POST OPERATIVE CAUSING FACTORS

Biomechanical Effects of Femoral Component Axial Rotation in Total Knee Arthroplasty (TKA)

Presented By Dr Vincent VG An MD BSc (Adv) MPhil Dr Murilo Leie MD Mr Joshua Twiggs BEng Dr Brett A Fritsch MBBS FRACS (Orth) FAOrthA.

Revolution. Unicompartmental Knee System

CLINICAL AND OPERATIVE APPROACH FOR TOTAL KNEE REPLACEMENT DR.VINMAIE ORTHOPAEDICS PG 2 ND YEAR

Distal Cut First Femoral Preparation

SEVERE VARUS AND VALGUS DEFORMITIES TREATED BY TOTAL KNEE ARTHROPLASTY

Where Is the Natural Internal-External Rotation Axis of the Tibia?

Sasaki E 1,2, Otsuka H 2, Sasaki N 2, and Ishibashi Y 1

KNEE. T. J. Shelton, A. J. Nedopil, S. M. Howell, M. L. Hull

THE KNEE SOCIETY VIRTUAL FELLOWSHIP

ANTERIOR REFERENCE NEXGEN COMPLETE KNEE SOLUTION. Multi-Reference 4-in-1 Femoral Instrumentation Anterior Reference Surgical Technique

Axial alignment of the lower extremity in Chinese adults. Journal Of Bone And Joint Surgery - Series A, 2000, v. 82 n. 11, p.

Multiapical Deformities p. 97 Osteotomy Concepts and Frontal Plane Realignment p. 99 Angulation Correction Axis (ACA) p. 99 Bisector Lines p.

Extramedullary Tibial Preparation

)116( COPYRIGHT 2016 BY THE ARCHIVES OF BONE AND JOINT SURGERY

How coronal alignment affects distal femoral anatomy: an MRI-based comparison of varus and valgus knees

TOTAL KNEE ARTHROPLASTY (TKA)

JOINT RULER. Surgical Technique For Knee Joint JRReplacement

Closing Wedge Retrotubercular Tibial Osteotomy and TKA for Posttraumatic Osteoarthritis With Angular Deformity

POSTERIOR REFERENCE NEXGEN COMPLETE KNEE SOLUTION. Multi-Reference 4-in-1 Femoral Instrumentation Posterior Reference Surgical Technique

Total Knee Original System Primary Surgical Technique

Tibial Base Design Factors Affecting Tibial Coverage After Total Knee Arthroplasty: Symmetric Versus Asymmetric Bases

Do Persons with PFP. PFJ Loading? Biomechanical Factors Contributing to Patellomoral Pain: The Dynamic Q Angle. Patellofemoral Pain: A Critical Review

VARIABILITY OF THE POSTERIOR CONDYLAR ANGLE

Intramedullary Tibial Preparation

2017 Resident Advanced Trauma Techniques Course COMPLICATIONS / CHALLENGES MALUNIONS/DEFORMITY

why bicompartmental? A REVOLUTIONARY ALTERNATIVE TO TOTAL KNEE REPLACEMENTS

Knee kinematics after TKA depends on preoperative kinematics

Zimmer FuZion Instruments. Surgical Technique (Beta Version)

Biomechanics of. Knee Replacement. Mujda Hakime, Paul Malcolm

Think isometry Feel balance

Zimmer NexGen. LPS-Flex Fixed Bearing Knee. Surgical Technique. Designed to accomodate resumption of high-flexion daily activities

Dora Street, Hurstville 160 Belmore Road, Randwick

Stephen R Smith Northeast Nebraska Orthopaedics PC. Ligament Preserving Techniques in Total Knee Arthroplasty

Where Is The Natural Flexion-Extension Axis Of The Knee?

Case Report Navigation-Assisted Total Knee Arthroplasty for Osteoarthritis with Extra-Articular Femoral Deformity and/or Retained Hardware

Lateral femoral sliding osteotomy

ANATOMIC. Navigated Surgical Technique 4 in 1 TO.G.GB.016/1.0

Abramsohn Retractor 1

A Non-CT Based Total Knee Arthroplasty System Featuring Complete Soft-Tissue Balancing

NexGen Legacy LPS-Flex Knee. Brochure

Method for Quantifying Patient Expectations and Early Recovery After Total Knee Arthroplasty

Results of an Initial Experience with Custom-fit Positioning Total Knee Arthroplasty in a Series of 48 Patients

Case Report Total Knee Arthroplasty in a Patient with Bilateral Congenital Dislocation of the Patella Treated with a Different Method in Each Knee

ClassiQ. Scorpio. Anterior Referencing Surgical Protocol. Anterior Referencing. For use with Scorpio ClassiQ Instrument System

CORRECTIVE OSTEOTOMY BRINGING THE PLAN TO THE BONE (TRIGONOMETERY, GUIDE WIRES, SLA MODELING AND ART)

Total knee arthroplasty (TKA) is an increasingly. Radiographic Evaluation of Alignment Following TKA, a Systematic Review

Effects of Posteromedial Vertical Capsulotomy on the Medial Extension Gap in Cruciate-retaining Total Knee Arthroplasty

unicompartmental knee SURGICAL TECHNIQUE limacorporate.com

Retrieved from DalSpace, the institutional repository of Dalhousie University

Stefan Rahm MD University Hospital Balgrist

Influence of patellar subluxation on ligament balancing in total knee arthroplasty through a subvastus approach. An in vivo study

Rotaglide+ TM. Total Knee System Product overview

Massive Varus- Overview. Massive Varus- Classification. Massive Varus- Definition 07/02/14. Correction of Massive Varus Deformity in TKR

PROPHECY INBONE. Preoperative Navigation Guides

Range of Motion of Standard and High-Flexion Posterior Stabilized Total Knee Prostheses A PROSPECTIVE, RANDOMIZED STUDY

A study of functional outcome after Primary Total Knee Arthroplasty in elderly patients

DIFFICULT PRIMARY TKA: VALGUS KNEE

Kinematics Analysis of Different Types of Prosthesis in Total Knee Arthroplasty with a Navigation System

The Geometry of the Trochlear Groove

)122( COPYRIGHT 2016 BY THE ARCHIVES OF BONE AND JOINT SURGERY RESEARCH ARTICLE

NexGen CR-Flex Fixed Bearing Knee. Surgical Technique

TOTAL KNEE ARTHROPLASTY SYSTEM

Robotic-Arm Assisted Total Knee Arthroplasty Demonstrated Greater Accuracy to Plan Compared to Manual Technique

BIOMECHANICAL MECHANISMS FOR DAMAGE: RETRIEVAL ANALYSIS AND COMPUTATIONAL WEAR PREDICTIONS IN TOTAL KNEE REPLACEMENTS

Early Results of Total Knee Replacements:

Gap Balancing vs. Measured Resection Technique in Total Knee Arthroplasty

Variations of the grand-piano sign during total knee replacement

Functional Outcome of Uni-Knee Arthroplasty in Asians with six-year Follow-up

Zimmer Unicompartmental High Flex Knee. Intramedullary, Spacer Block Option and Extramedullary Minimally Invasive Surgical Techniques

CLINICAL FINDINGS USING THE VERASENSE KNEE SYSTEM THE INTELLIGENT CHOICE FOR FLEXION STABILITY

The UniSpacer : correcting varus malalignment in medial gonarthrosis

Aseptic Revision Total Knee Surgical Techniques. Andrew Ehmke, DO Chicago, IL May 5, 2018

1 Introduction. 2 Data and method

Correlation between Knee Kinematics and Patello-femoral Contact Pressure in Total Knee Arthroplasty

LAMINA SPREADER SURGICAL TECHNIQUE

Lateralization of Tibial Plateau Reference Point Improves Accuracy of Tibial Resection in Total Knee Arthroplasty in Patients with Proximal Tibia Vara

Saiph Knee System. Technical Dossier

Biomechanics of the Knee. Valerie Nuñez SpR Frimley Park Hospital

Clinical evaluation of 292 Genesis II posterior stabilized high-flexion total knee arthroplasty: range of motion and predictors

The Knee. Two Joints: Tibiofemoral. Patellofemoral

POSTERIOR 1. situated behind: situated at or toward the hind part of the body :

Clinical Study Accuracy of Implant Placement Utilizing Customized Patient Instrumentation in Total Knee Arthroplasty

Soft-tissue and alignment correction

COMPUTER ASSISTED ROBOTIC TOTAL KNEE ARTHROPLASTY

)289( COPYRIGHT 2018 BY THE ARCHIVES OF BONE AND JOINT SURGERY RESEARCH ARTICLE

Knee Joint Anatomy 101

Transcription:

Kinematic vs. mechanical alignment: What is the difference? In this 4 Questions interview, Stephen M. Howell, MD, explains the potential benefits of 3D alignment during total knee replacement. Introduction The topic and arguments concerning mechanical vs. kinematic alignment of knee replacements can be confusing the first few times you read about it. This month I asked Stephen M. Howell, MD, to respond succinctly to four related questions. The purpose of these questions is to give further insight to our readers as they listen to future presentations and read new literature published on this topic. Douglas W. Jackson, MD Chief Medical Editor Douglas W. Jackson, MD: What does the mechanical alignment of a total knee mean? Story continues below ADVERTISEMENT Stephen M. Howell, MD: Mechanical alignment considers only the two-dimensional (2D) alignment of the limb and knee in the coronal or frontal plane. Devotees of navigational instruments strive to cut the distal femur perpendicular to a line drawn from the center of the femoral head to the center of the knee the mechanical axis of the femur and cut the proximal tibia perpendicular to a line drawn from the center of the knee to the center of the ankle the mechanical axis of the tibia. Most surgeons using conventional instruments place an intramedullary rod in the distal femur set at a fixed angle (usually 5 or 6 ) to make the distal femoral cut and use an extramedullary guide to make the classic tibial cut perpendicular to the mechanical axis of the tibia. In most patients, mechanically aligning the limb and components to a neutral or 0 hip-knee-ankle angle changes the obliquity and raises the joint line from normal. These changes in the joint line require a compensatory change in the axial rotation of the femoral component to minimize the inevitable imbalance of the collateral and retinacular ligaments. However, placing the femoral component at a different obliquity and level of joint line from normal alters the patellofemoral and tibiofemoral kinematics, which can cause patellofemoral pain, instability, and loss of motion. 1 of 5 10/15/10 9:50 PM

These changes in the joint line result from referencing the center of the femoral head and ankle and are caused by the wide variability and unrelated longitudinal shapes of the femur and tibia in a given limb. The variability and unrelated longitudinal shapes of the femur and tibia explains why only 2% of normal limbs have a 0 hip-knee-ankle angle. Changing the obliquity and level of the joint line from normal often requires releases of the collateral and lateral retinacular ligaments and is believed to lead to increased wear and explain the 18% to 25% prevalence of patients not satisfied with their total knee arthroplasty (TKA). Jackson: How does this differ from kinematic alignment of the knee? Stephen M. Howell Howell: Kinematic alignment considers the 3D alignment of the components with respect to the knee instead of the 2D alignment of the components with respect to the center of the femoral head and ankle. The intent of kinematic alignment is the restoration of the normal 3D orientation of the three axes that describe normal knee kinematics. By definition, the three kinematic axes are a transverse axis in the femur about which the tibia flexes and extends, a transverse axis in the femur about which the patella flexes and extends, and a longitudinal axis in the tibia about which that tibia internally and externally rotates on the femur. The parallel and orthogonal relationships between these three axes do not vary between knees. Standing radiographs comparing the mechanical axis (right), joint line (center), and anatomic alignment (right) of bilateral knee replacements performed with kinematic and mechanical alignment. Images: Howell SM In TKA, the two parallel transverse axes in the femur about which the tibia and patella flex and extend are re-established by surface or shape-fitting a femoral component with symmetric, single-radius condyles on the articular surface of the femur after correcting for wear. Intraoperatively, kinematic alignment is performed with patient-specific guides. Kinematic alignment of the femoral component is confirmed when the thickness of the two distal and two posterior bone resections plus the thickness of the wear (typically 1 mm to 2 mm) plus the thickness of the kerf from sawing the bone (typically 1 mm to 1.5 mm) equals the thickness of the femoral component. For a typical varus knee reconstructed with 8 -mm thick distal and posterior femoral condyles on the femoral component, the thickness of the distal medial resection should be 5 mm, the posterior medial resection should be 6 mm, and the distal and posterior lateral resections should be 7 mm. If the femoral component is 10-mm thick then each bone resection should be 2-mm thicker than the cuts for an 8-mm thick femoral component. For a typical valgus knee, the pattern of the bone resections should be reversed with the thinner resections lateral and the thicker resections medial. Rarely is additional removal of bone from the distal femur required to correct a flexion contracture. 2 of 5 10/15/10 9:50 PM

Recreation of the knee pre- and postoperative demonstrating the three kinematic axes. The orange vertical lines demonstrate the longitudinal axis; the purple horizontal lines represent the transverse axis about which the patella flexes and extends and the green horizontal lines represent the transverse axis about which the tibia flexes and extends. Jackson: Can the alignments be the same in a given patient? Howell: Surprisingly, the coronal alignment of the limb the hip-knee-ankle angle and the alignment of the knee the femoral-tibial angle are the same in kinematically and mechanically aligned TKA. The main difference is in the alignment of the components with respect to the weight-bearing line connecting the centers of the femoral head and ankle. Kinematic alignment restores the obliquity and level of the joint line anatomically so the femoral component is slightly more valgus (1 to 2 ) and the tibial component is slightly more varus (1 to 2 ) than mechanically aligned components. Mechanically aligning the TKA changes the obliquity and level of joint line from normal requiring a compensatory change in the axial rotation of the femoral component to minimize the inevitable imbalance of the collateral and retinacular ligaments. Assuming that the alignment of the limb and knee are important for the longevity of the prosthesis; kinematic and mechanical alignment methods should have similar rates of wear, loosening, and survival. 3 of 5 10/15/10 9:50 PM

Howell said patients with kinematically aligned TKA have better clinical outcomes, better motion and a quicker recovery than patients who have mechanical alignment. Jackson: What do you see as the potential benefits to the patient from obtaining the desired kinematic alignment? Howell: Most surgeons that have performed kinematically aligned TKA have noticed an overall better clinical outcome, better motion, better patient satisfaction, and a quicker recovery than their patients treated with mechanically aligned TKA. These clinical impressions are supported by an in vivo study of contact mechanics that showed the kinematically aligned prosthesis had a minimal prevalence of adduction (3%) and reverse axial rotation (8.5%), which were less and closer to normal than reports of mechanically aligned TKA. However, as with any surgical technique, careful attention to detail is required as poor outcomes can occur when the principles of kinematic alignment are not followed. The most helpful intraoperative check is the measurement of the distal and posterior femoral bone resections. Adjusting the thickness of the bone resections to accommodate for the 1 mm to 2 mm of distal and posterior wear on the worn side and kerf confirms the femoral component is kinematically positioned before cementing. Although the principles of kinematic alignment are time honored since first described by Hollister in 1993, the first clinical use of kinematic alignment in TKA in January 2006 is relatively new. Additional studies are needed to further evaluate the advantages and disadvantages of the use of kinematic alignment in TKA with respect to other alignment methods. We are awaiting a Level 1 randomized, double blind, clinical trial to determine the differences and similarities in alignment, clinical outcome, and motion between kinematically and mechanically aligned TKA. Editor's Note This article is different than it appeared in the print version of Orthopedics Today. This online version is the version of record. Reference: Baker PN, van der Meulen JH, Lewsey J, Gregg PJ. The role of pain and function in determining patient satisfaction after total knee replacement. Data from the National Joint Registry for England and Wales. J Bone Joint Surg (Br). 2007;89(7):893-900. Coughlin KM, Incavo SJ, Churchill DL, Beynnon BD. Tibial axis and patellar position relative to the femoral epicondylar axis during squatting. J Arthroplasty. 2003;18(8):1048-1055. Dossett GH. Total Knee Replacement Study Using Standard Cutting Guide vs Otismed MRI Generated Cutting Guide. ClinicalTrials.gov. Phoenix: Department of Veterans Affairs (Phoenix, AZ); 2010. Eckhoff D, Hogan C, DiMatteo L, Robinson M, Bach J. Difference between the epicondylar and cylindrical axis of the knee. Clin Orthop Relat Res. 2007;461:238-244. Eckhoff DG, Bach JM, Spitzer VM, et al. Three-dimensional mechanics, kinematics, and morphology of the knee viewed in virtual reality. J Bone Joint Surg (Am). 2005;87 Suppl 2:71-80. 4 of 5 10/15/10 9:50 PM

Hollister AM, Jatana S, Singh AK, Sullivan WW, Lupichuk AG. The axes of rotation of the knee. Clin Orthop Relat Res. 1993(290):259-268. Howell SM, Hodapp EE, Kuznik K, Hull ML. In vivo adduction and reverse axial rotation (external) of the tibial component can be minimized. Orthopedics. 2009;32(5):319. Howell SM, Howell SJ, Hull ML. Assessment of the radii of the medial and lateral femoral condyles in varus and valgus knees with osteoarthritis. J Bone Joint Surg (Am). 2010;92(1):98-104. Howell SM, Kuznik K, Hull ML, Siston RA. Longitudinal shapes of the tibia and femur are unrelated and variable. Clin Orthop Relat Res. 2009. Howell SM, Rogers SL. Method for quantifying patient expectations and early recovery after total knee arthroplasty. Orthopedics. 2009;32(12):884-890. Noble PC, Conditt MA, Cook KF, Mathis KB. The John Insall Award: Patient expectations affect satisfaction with total knee arthroplasty. Clin Orthop Relat Res. 2006;452:35-43. Spencer BA, Mont MA, McGrath MS, Boyd B, Mitrick MF. Initial experience with custom-fit total knee replacement: intraoperative events and long-leg coronal alignment. Int Orthop. 2008. Stephen M. Howell, MD, can be reached at Timberlake Professional Building, 8100 Timberlake Way, Suite F, Sacramento, CA 95823; 916-689-7370; e-mail: sebhowell@mac.com. He is a consultant to Biomet Sports Medicine Inc., an unpaid consultant to OtisMed Inc., receives royalties from Biomet Sports Medicine Inc. and is a stockholder in OtisMed Inc. Follow OrthoSuperSite.com on Twitter 5 of 5 10/15/10 9:50 PM