Crystal Collimation Cleaning Measurements with Proton Beams in LHC

Similar documents
LHC Collimation Status and Plans

Collimation Experience at the Large Hadron Collider

CONCEPTUAL SPECIFICATION TECG FOR CRYSTAL COLLIMATION AT THE LHC WP5

DPA calculations with FLUKA

MD Landau Damping: Beam Transfer Functions and diffusion mechanisms

CONCEPTUAL SPECIFICATION TARGET COLLIMATOR LONG DISPERSION SUPPRESSOR P7 [TCLD]

A Comparison of Interaction Physics for Proton Collimation Systems in Current Simulation Tools

First (preliminary) results from BTF measurements in the LHC

Halo Collimation Depth Using BDSIM

CREX Magnet Considerations

Double Stage Seeded FEL With Fresh Bunch Injection Technique at FERMI

Beam Loss and Collimation in the ESS Linac

A new geometric and mechanical verification device for medical LINACs

The LHC Collimation System

High-Level Dosimetry systems used at CERN

Modified Collimation Layout & Optics (for cryogenic collimators in IR3 with maximum 4.5 m displacement of elements )

The LARP Collimation Program

Custom-Made Products / Scientific Research Instruments

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

Evidence of intrinsic ferromagnetism in individual dilute magnetic semiconducting nanostructures O-K. (a) Zn-L Zn-L 2,3

New Treatment Research Facility Project at HIMAC

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

Nuclear Associates

LHC Physics or How LHC experiments will use OSG resources

ISR and LEP collimation. What can be learned for LHC?

CHARACTERIZATION OF THE ELECTRON BEAM RADIATION FIELD BY CHEMICAL DOSIMETRY

SpiderX. Portable Residual Stress X-Ray Diffractometer.

FERMI: EUV and Soft X-Ray FELs with HGHG

III. Proton-therapytherapy. Rome SB - 5/5 1

Task Test beam infrastructure in Frascati LNF, Ferrara & Perugia INFN structure and University of Bergen

RESULTS OF THE LHC DCCT CALIBRATION STUDIES

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies

Biopac Student Lab Lesson 6 ELECTROCARDIOGRAPHY (ECG) II Analysis Procedure. Rev

The DAΦNE Beam Test Facility & AGILE Calibration

Cheiron School BL Practice of BL38B1 (Protein Crystallography)

LECTURE 13. Dr. Teresa D. Golden University of North Texas Department of Chemistry

ACCELERATOR DESIGN ISSUES IN CANCER THERAPY

Development of a Goniometer with Nanoradian Accuracy

Neutrons. ρ σ. where. Neutrons act like photons in the sense that they are attenuated as. Unlike photons, neutrons interact via the strong interaction

The ANDANTE project: a multidisciplinary approach to neutron RBE

Alignment and Calibration of the APEX Instrument. March 30, Chemical Crystallography Laboratory

IMPT with Carbon Ions

Methods of optical measurement for directional light/led-sources and luminaires.

Market Survey. Technical Description Irradiation Tests

Radiotherapy. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

First Demonstration of High Gain Lasing and Polarization Switch with a Distributed Optical Klystron FEL at Duke University

Application of Implanted Markers in Proton Therapy. Course Outline. McLaren Proton Therapy Center Karmanos Cancer Institute McLaren - Flint

arxiv: v1 [physics.ins-det] 1 Feb 2015

Outline Fermi experimental setup Impact of the laser heater on seeded FEL Non-Gaussian effects 2

OPERATION AND PATIENT TREATMENTS AT CNAO FACILITY

8 Performing Medical Procedures

Developments in Ultrasonic Inspection II

Performance of phased array and conventional ultrasonic probes on the new ISO reference block

DEVELOPMENT OF ELECTROMAGNETIC ACOUSTIC TRANSDUCER (EMAT) PHASED ARRAYS FOR SFR INSPECTION

A low magnification SEM image of the fabricated 2 2 ZnO based triode array is

Noninvasive Blood Glucose Analysis using Near Infrared Absorption Spectroscopy. Abstract

A Method for Statistical Process Control of Radiation Sterilization Facilities

Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion

Nuclear Data for Radiation Therapy

Bruker D8 Discover User Manual (Version: July 2017)

6/29/2012 WHAT IS IN THIS PRESENTATION? MANAGEMENT OF PRIMARY DEVICES INVESTIGATED MAJOR ISSUES WITH CARDIAC DEVICES AND FROM MED PHYS LISTSERVS

EXPERIMENTAL RESULTS IN PERCENTAGE DEPTH DOSE (PDD) DETERMINATION AT THE EXTENDED DISTANCES *

Instruction Manual No A. Goniometer PS-2138, PS-2137

ACCELERATORS FOR HADRONTHERAPY

Heavy Ion Tumor Therapy

Measurement of Dose to Implanted Cardiac Devices in Radiotherapy Patients

w. D. Jolly, F. A. Bruton, and C. Fedor

The Heidelberg Ion Therapy Center. Thomas Haberer Heidelberg Ion Therapy Center Hadron Therapy Workshop, Erice 2009

The first year of operation of PSI s new SC cyclotron and beam lines for proton therapy.

Plan-Specific Correction Factors for Small- Volume Ion Chamber Dosimetry in Modulated Treatments on a Varian Trilogy

H. Röcken, M. Abdel-Bary, E. Akcöltekin, P. Budz, T. Stephani, J. Wittschen

Descriptions of NDT Projects Fall 2004 October 31, 2004

Rotating and static sources for gamma knife radiosurgery systems: Monte Carlo studies

Titronics Range of Motion Hardware & Software Installation

Characterization and implementation of Pencil Beam Scanning proton therapy techniques: from spot scanning to continuous scanning

A comparison of dose distributions measured with two types of radiochromic film dosimeter MD55 and EBT for proton beam of energy 175 MeV

STUDY OF PHASED ARRAY TECHNIQUES FOR CONCRETE INSPECTION

Specifics of treatment planning for active scanning and IMPT

THE RIGAKU JOURNAL VOL. 23 / 2006, A1-A10 CONSIDERATIONS REGARDING THE ALIGNMENT OF DIFFRACTOMETERS FOR RESIDUAL STRESS ANALYSIS

Motorized Precision Goniometer

CLAS12 FTOF Studies: Rate and Magnetic Shielding Effects on PMT Timing Resolutions

Imaging of Scattered Radiation for Real Time Tracking of Tumor Motion During Lung SBRT


Dual channel photoplethysmography studies of cardio-vascular response to the body position changes

Cancer Treatment by Charged Particles - Carbon Ion Radiotherapy -

APPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS

Intensity Modulated RadioTherapy

NDT PERFORMANCE DEMONSTRATION USING SIMULATION

ADVANCED PHASED ARRAY TECHNOLOGIES

CT Scanning Protocol For V2R Guided Surgery Solutions

Nature Neuroscience: doi: /nn Supplementary Figure 1

Scanora 3D Scanning Protocol

A new method of sonograph lateral resolution measurement using PSF analysis of received signal

Frank: Merrill's Atlas of Radiographic Positioning & Procedures, 12th Edition

ONE THOUSAND WAVEFRONT GIDED TREATMENT ON MICROSCAN VISUM. Mickael Yablokov. I have no any financial interests in any products mentioned in this paper

Radiation qualities in carbon-ion radiotherapy at NIRS/HIMAC

International Association of Scientific Innovation and Research (IASIR) (An Association Unifying the Sciences, Engineering, and Applied Research)

Application of Phased Array Radar Theory to Ultrasonic Linear Array Medical Imaging System

mardtb Goniostat for X-ray crystallography

Flume Installation Instructions

Transcription:

CERN-ACC-Note-2018-0024-MD 2016.07.29 Roberto.Rossi@cern.ch Crystal Collimation Cleaning Measurements with Proton Beams in LHC R. Rossi, O. Aberle, O. O. Andreassen, M. Butcher, C. A. Dionisio Barreto, A. Masi, D. Mirarchi, S. Montesano, I. Lamas Garcia, S. Redaelli, W. Scandale, P. Serrano Galvez, A. Rijllart, G. Valentino, CERN, Geneva, Switzerland, F. Galluccio, INFN-Napoli, Naples, Italy Keywords: LHC, collimation, crystal, UA9 Summary During this MD, performed on July 29 th, 2016, bent silicon crystal were tested with proton beams for a possible usage of crystal-assisted collimation. Tests were performed at both injection energy and flat top using horizontal and vertical crystal. Loss maps with crystals at 6.5 TeV were measured. 1 Introduction During LS1, two bent crystals for beam collimation studies were installed in IR7, on two goniometers on beam 1. In 2015 the two crystals were tested, and channeling was successfully observed for both proton and ion beams [1, 2, 3]. The main goals of beam tests in 2016 with those devices are to compare the crystal collimation cleaning performances to the actual collimation system cleaning at 6.5 TeV, and to assess the reliability of the goniometers in dynamical operation phases like the energy ramp. The crystal collimation concept relies on the usage of bent crystals that can channel halo particles at large angles of up to tens of µrad. As opposed to the standard LHC multi-stage collimation, where amorphous primary collimators scatter halo particles at µrad angles onto several secondary collimators, crystal primaries could send halo particles in one single absorber per plane. A setup has been conceived that uses only existing secondary collimators as absorbers for the channeled beam [4]. The scope of those MD is to demonstrate that channeling can be achieved and that a good collimation cleaning can be produced with a reduced set - ideally with one - secondary collimator. In this note, the beam setup and machine configuration for the tests carried out in MD1 of 2016 are presented. This MD was devoted to measuring for the first time the crystal- 1

collimation cleaning performance at 6.5 TeV. Also, tests of vertical crystals at top energy were carried out for the first time. Those tests could not be carried in 2015 due to lack of time. Some initial conclusions are then drawn. 2 Beam Setup The MD was performed using several low-intensity bunches both at injection and flat top energy, with the standard 2016 optics. The transverse dumper (ADT) was used to excite selected bunches by applying a transverse white noise, as in standard collimation loss maps, to achieve controlled primary beam losses on crystals and/or collimators. This was the reason why several low-intensity bunches were used at flat top energy: excitations of individual bunches allowed several measurements in one single cycle to 6.5 TeV. To have enough losses for the time needed to complete crystal and collimator scans (see below), the ADT window was actually enlarged to act on three consecutive bunches. A specific filling scheme was prepared with groups of three pilots separated by 2 µs from each other, and each group separated by 3.5 µs from the following. The overall LHC availability during those studies was good. All the scheduled measurements were performed. The measurements involved the following main activities: 1) beam-based alignment of the crystal with respect to the beam orbit and transverse positioning as primary collimator; 2) setup for crystal based system: crystal as primary collimator, and several TCSGs open; 3) angular scan for the determination of the channeling condition; 4) transverse scan of the channeled beam with a secondary collimator; 5) cleaning measurements through loss maps of a reduced collimation system based on a crystal in channeling position and different sets of secondary collimators. The first step is performed in a similar way as a standard collimator jaw alignment and is not presented in detail. In the following section, the results of measurements (3), (4) are presented for both energies. Cleaning measurements (5) were performed for the first time. 3 Measurements 3.1 Injection Energy Checks The first operation of the MD was to repeat a minimal set of measurements for the horizontal and vertical crystals at injection energy. Angular scans are performed by changing the crystal angle while monitoring beam losses immediately downstream of the crystals, following the detailed procedure described in [2]. The reason for this procedure was to check the angular reproducibility of the goniometer after several months and several updates to the control system. It is also important to assess channeling orientations to optimize the setup at top 2

Hor Crystal BLM / Beam Flux / AM losses [a.u.] 1 1 Horizontal Crystal Angular Scan @ 6500 GeV 2016 07 29 15:49:00 Vertical Crystal BLM / Beam Flux [a.u.] 1 1 Vertical Crystal Angular Scan at Flat Top 1960 1980 2000 2020 2040 Horizontal Crystal Angle [µrad] 2160 2170 2180 2190 2200 22 2220 2230 Vertical Crystal Angle [µrad] Figure 1: Horizontal (Left) and Vertical (Right) crystal angular scans at top energy. Losses normalized to the beam flux as a function of the goniometer angle. energy. Both vertical and horizontal crystals were tested. Angular scans were performed to reestablish the channeling orientation angle with the procedure described in [1]. 3.2 Flat top energy measurements The results of the angular scans of vertical crystal are shown in Fig. 1. These measurements were recorded with the collimator settings listed in Table 1. Losses recorded at 1 Hz, normalized to the bunch by bunch flux, and to the steady losses measurement with crystals in amorphous orientation, are used to produce this plot. The beam flux is calculated by fitting with a 3rd order polynomial function the slope in the beam current. The vertical crystal was tested for the first time at top energy, due to lack of time in 2015 tests. It was found that in channeling losses are reduced with respect to amorphous orientation by factors 26 and 23 for horizontal and vertical crystals, respectively. Standard Horizontal scan Vertical scan IR7 [σ] [σ] [σ] TCP 5.5 7.5 7.5 TCPCV Out Out 5.5 TCPCH Out 5.5 7.5 TCSG 7.5 7.5 7.5 TCLA 11.0 11.0 11.0 Table 1: IR7 s positions (in σ units) during flat top standard operation and crystals scan operation. 3.3 Absorber Linear Scan As for injection energy tests, in order to characterize the properties of the channeled beam one can make a transverse scan with secondary collimators located downstream of the crystal. When the crystal is oriented at its optimum angle for channeling the halo has its maximum distance from the beam envelope. A scan can then be performed with the secondary collimators TCSG.B4L7 and TCSG.D4L7 for horizontal and vertical crystal respectively. During 3

Hor Absorber BLM / Beam Flux [a.u.] 8 6 4 Horizontal Crystal Scraping @ 6500 GeV Ver Absorber BLM / Beam Flux [a.u.] 9 8 7 6 5 4 3 Vertical Crystal Scraping @ 6.5 TeV 2 2 1 0 7.5 7 6.5 6 5.5 5 4.5 4 3.5 3 Absorber position [mm] 0 4 3.5 3 2.5 2 1.5 Absorber position [mm] Figure 2: Horizontal (Left) and Vertical (Right) crystal channeled beam scrapings. Losses normalized to the beam intensity as a function of the absorber linear position. these measurements, all the collimators located upstream of the secondary collimator used for the scan were opened to at least 7.5 σ. Inward and/or outward scans are performed by spanning the range in transverse amplitude between the primary beam envelope, defined by the crystal position and apertures where the collimator jaw does not intercept the channeled beam anymore. In this condition the channeled halo is intercepted by downstream collimators. The measurement is given in Figs. 2, where the losses recorded downstream of the secondary collimator used for the scan are given as a function of the collimator jaw position. 4 Cleaning measurements Loss maps were measured both in horizontal and vertical planes of beam 1, for standard and crystal based collimation system settings. Crystal collimation only uses a sub set of the secondary collimators, that are all used compared in the standard system. In standard collimation loss maps, cleaning inefficiency is measured by normalizing all the monitors (BLM) to the losses recorded at the highest BLM close to the primary collimators. This value is proportional to the number of halo particles intercepted by the collimation system, hence the losses in the dispersion suppressor region (DS) of IR7 give a direct measurement of collimation inefficiency. Channeling however suppress nuclear interaction, so losses at the crystal are small and they are maximum at the secondary collimator used as absorber. It is not possible to compare the two system by using the same normalization of the BLM signal used for the standard system. For a direct comparison of absolute losses, we therefore use a different normalization. Each BLM signal in Gy/s is normalized by the flux of primary beam losses in p/s calculated from the bunch by bunch beam current measurements. The leakage factor is defined as the highest normalized loss value observed in IR7-DS during a loss map. Standard collimation loss maps were measured as reference to compare the two systems. For the crystal system, different arrangements of the TCSGs downstream of the crystal were tested. In Table 2 the different settings used are presented. The leakage ratios found in IR7- DS, on two different cold magnets position, and on momentum cleaning primary collimator (TCP IR3), are presented in Table 3. In the horizontal plane, we observed an improvement of standard collimation below the 4

Standard Horizontal Vertical [σ] [σ] [σ] Configuration Reference 1 2 3 4 5 1 2 3* TCP.D6L7 5.5 7.5 7.5 7.5 7.5 7.5 Out Out Out TCP.C6L7 5.5 7.5 7.5 7.5 7.5 7.5 Out Out Out TCP.B6L7 5.5 7.5 7.5 7.5 7.5 7.5 Out Out Out TCSG.A6L7 7.5 7.5 7.5 7.5 7.5 7.5 Out Out Out TCPCV.A6L7 Out Out Out Out Out Out 5.5 5.5 5.5 TCSG.B5L7 7.5 7.5 7.5 7.5 7.5 7.5 Out Out Out TCSG.A5L7 7.5 7.5 7.5 7.5 7.5 7.5 Out Out Out TCSG.D4L7 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 TCPCH.A4L7 Out 5.5 5.5 5.5 5.5 5.5 Out Out Out TCSG.B4L7 7.5 7.5 7.5 7.5 7.5 Out 7.5 Out 7.5 TCSG.A4L7 7.5 7.5 7.5 Out Out Out 7.5 Out 7.5 TCSG.A4R7 7.5 7.5 7.5 Out Out Out 7.5 Out 7.5 TCSG.B5R7 7.5 7.5 Out Out Out Out 7.5 Out 7.5 TCSG.D5R7 7.5 7.5 Out Out Out Out 7.5 Out 7.5 TCSG.E5R7 7.5 7.5 Out Out Out Out 7.5 Out 7.5 TCSG.6R7 7.5 7.5 7.5 7.5 7.5 7.5 7.5 Out 7.5 TCLA.A6R7 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 TCLA.B6R7 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 TCLA.C6R7 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 TCLA.D6R7 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 TCLA.A7R7 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 Table 2: IR7 s positions (in σ units) during flat top Loss Maps measurements. 2016 operational performance. In particular, what appears to be the effect of showers coming from TCLAs is affecting the region Q7. If we look at the Q8 region the max improvement is a factor 3. It is also observable how reducing the set of TCSGs is affecting the crystal collimation performances. Simulations of loss maps with this settings are in progress to assess the hypothesis made before. For vertical crystal, an improvement by a factor 9.17 is observed in IR7-DS, with a reduction of losses on IR3 TCP by a factor 14.13. When a reduced set of TCSGs is used the system shows the same behavior observed for horizontal case: with limited or no improvement of the cleaning. Also, a loss map with vertical crystal in amorphous orientation was measured; it is possible to observe the differences in the loss pattern. ADD REFERENCE TO FIGURE. In particular, the monitors at crystal and at the absorber position (TCSG.D4L7 in this case) show a quantitative behavior. When in channeling losses at crystal position are about 2 order of magnitude lower than at the absorber, when in amorphous they are about 1 order of magnitude less. 5

Plane Configuration Crystal Leackage ratio Orientation Standard/Crystal IR7-DS Q7 IR7-DS Q8 TCP IR3 H 1 CH 1.85 4.71 3.72 H 2 CH 1.60 4.21 3.34 H 3 CH 0.75 2.89 2.22 H 4 CH 0.18 1.20 2.47 H 5 CH 0.22 1.41 2.80 V 1 CH 9.17 14.13 V 2 CH 0.92 4.58 5.63 V 3 AM 0.49 0.47 Table 3: IR7 s positions (in σ units) during flat top standard operation and crystals scan operation. 5 Conclusions The setup for crystal collimation tests in IR7 was tested again to confirm the stability of the goniometers at injection energy and top energy. For the first time channeling was observed with vertical crystal, that is a Quasi Mosaic crystal, with protons at 6.5 TeV. Channeling for horizontal crystal confirmed as in 2015. Evidence of channeling comes from the monitoring of local losses downstream of the crystals, which are suppressed in channeling compared to amorphous orientations, and from scans of secondary collimators further downstream, which indicate the presence of a well-defined channeled halo separated from the beam core. Those tests were preliminary carried out with both crystals at both energies, providing a comprehensive set of data for a full characterization of both crystals. The preliminary analysis indicates that a crystal based system can improve, both in horizontal and vertical planes, the cleaning of present multi stage system. In the best cases, improvement factors of DS losses of 4.7 (H) and 9.17 (V) could be achieved. It is important to note that this improvements can only be achieved if a large number of secondary collimators downstream of the crystal are used. If only one TCSG per plane is used, the performance of a crystal based system is still good but not better than the present system. This is a feature of the present setup for low beam intensity tests, which uses only 1 m of CFC as primary absorber. 6 Acknowledgements We would like to thank the OP crew for their assistance during the MD. 6

7 Appendix Figure 3: Horizontal standard loss maps. IR7 zoom is Betatron losses B1 6500 GeV Horizontal 2016 7 29 16:16:18 0 5000 000 15000 20000 25000 Betatron losses B1 6500 GeV Horizontal 2016 7 29 16:16:18 η=1.3e Figure 4: Horizontal crystal collimation loss maps. Settings 1 on Table 3. IR7 zoom is Betatron losses B1 6500 GeV Horizontal 2016 7 29 16:33:21 η=1.7e Figure 5: Horizontal crystal collimation loss maps. Settings 2 on Table 3. IR7 zoom is 7

Betatron losses B1 6500 GeV Horizontal 2016 7 29 16:36:00 η=3.2e Figure 6: Horizontal crystal collimation loss maps. Settings 3 on Table 3. IR7 zoom is Betatron losses B1 6500 GeV Horizontal 2016 7 29 16:38:45 η=1.3e Figure 7: Horizontal crystal collimation loss maps. Settings 4 on Table 3. IR7 zoom is Betatron losses B1 6500 GeV Horizontal 2016 7 29 16:56:55 η=1.1e Figure 8: Horizontal crystal collimation loss maps. Settings 5 on Table 3. IR7 zoom is 8

Figure 9: Vertical standard loss maps. IR7 zoom is Betatron losses B1 6500 GeV Vertical 2016 7 29 19:47:50 η=2.4e Figure : Vertical crystal collimation loss maps. Settings 1 on Table 3. IR7 zoom is Betatron losses B1 6500 GeV Vertical 2016 7 29 20:04:16 η=2.4e Figure 11: Vertical crystal collimation loss maps. Settings 2 on Table 3. IR7 zoom is 9

Betatron losses B1 6500 GeV Vertical 2016 7 29 20:40:47 η=4.5e Figure 12: Vertical crystal collimation loss maps, crystal in amorphous orientation. Settings 3 on Table 3. IR7 zoom is

References [1] R. Rossi et al., Crystal Collimation with protons at injection energy, MD Note, CERN- ACC-NOTE-2016-0035, 2016 [2] R. Rossi et al., Crystal Collimation with protons at flat top energy, MD Note, CERN- ACC-NOTE-2017-0021, 2017 [3] R. Rossi et al., Crystal Collimation with Lead Ion Beams at Injection Energy in the LHC, MD Note, CERN-ACC-Note-2018-0004, 2018 [4] D. Mirarchi, Crystal Collimation for LHC, PhD Thesis, CERN-THESIS-2015-099, 2015 [5] W. Scandale et al., Probability of inelastic nuclear interactions of high-energy protons in a bent crystal, NIM B 268 2655-2659, 20 [6] W. Scandale et al.,volume reflection dependence of 400 GeV/c protons on the bent crystal curvature, Phys. Rev. Lett. 1 234801, 2008 11