With new technology available to

Similar documents
Insulin Pumps and Continuous Glucose Sensors- Embracing Technology. Susan Cavalier, BS, RN, CDE Manager, Diabetes Educator Sanford Diabetes Education

Updates in Diabetes Technology

MEDICAL POLICY Continuous Glucose Monitoring Systems and Insulin Pumps

NEW TECHNOLOGIES FOR MANAGING DIABETES ANGELA THOMPSON DNP, FNP-C, BC-ADM, CDE, FAANP

Advances in Diabetes Care Technologies

Diabetes Technology Update. Sarah Konigsberg, MD Diabetes & Endocrine Assoc. April 7, 2018

06/13/17. A. Completed a comprehensive diabetes education program within the past two years; and

Approved by: Integrated Health Quality Management Subcommittee Effective Date: Department of Origin: Integrated Healthcare Services.

Advances in Technology in the Treatment of Diabetes Mellitus 2017 How far have we come-how far are we going? Is there a final frontier?

10:20 AM March 5, B 100% 235 u. 124 mg/dl 3 HRS INSULIN ON BOARD:

UNDERSTANDING THE BASIC FEATURES AND MANAGEMENT IN THE SCHOOL SETTING CHRISTINE HERTLER RN BSN CDE & MARY MCCARTHY RN CDE

The Realities of Technology in Type 1 Diabetes

Predicts and helps prevent lows with. zero fingersticks NOW FEATURING BASAL-IQ TECHNOLOGY

The Growing Future of Diabetes: Insulin Pump Therapy in Type 1 and 2 Diabetes

Artificial Pancreas Device Systems. Populations Interventions Comparators Outcomes Individuals: With type 1 diabetes

Diabetes II Insulin pumps; Continuous glucose monitoring system (CGMS) Ernest Asamoah, MD FACE FACP FRCP (Lond)

Advances in Diabetes Care Technologies

Artificial Pancreas Device System (APDS)

Technology for Diabetes: 101 Basic Rules of the Road. Karen Hamon RN, BSN, CDE Stephen Stone MD, FAAP Neil H. White, MD, CDE

Designed with your patients lives in mind

Artificial Pancreas Device Systems. Populations Interventions Comparators Outcomes. pump. pump

MEDICAL POLICY Continuous Glucose Monitoring Systems and Insulin Pumps

Report Reference Guide

Diabetes and Technology. Saturday, September 9, 2017 Aimee G sell, APRN, ANP-C, CDE

Insulin Pumps Available in Canada

CareLink. software REPORT REFERENCE GUIDE. Management Software for Diabetes

1. Continuous Glucose Monitoring

Comparative table of insulin pumps

Pumping Insulin is it for your patients?

MEDICAL POLICY Continuous Glucose Monitoring Systems and Insulin Pumps

WHEN YOUR PANCREAS IS NOT A HAPPY CAMPER A PRESENTATION ON DIABETES MANAGEMENT IN THE CAMP SETTING AMANDA COSCHI, BSCN, RN, CDE

WOULD YOU LIKE MORE CONFIDENCE IN YOUR HYPOGLYCAEMIC CONTROL? SMARTGUARD. PROVIDES PREDICTIVE PROTECTION

1 Dexcom G4 Platinum User Guide May 2012

Corporate Medical Policy

Objectives. The Problem. We ve come a LONG way, Innovations in Diabetes Care and Management. Barbara Walz, RN, BSN, CDE April 26, 2018

Future Direction of Artificial Pancreas. Roy W. Beck, MD, PhD. JAEB Center for Health Research Tampa, Florida

CGM Use in Pregnancy & Unique Populations ELIZABETH O. BUSCHUR, MD THE OHIO STATE UNIVERSITY WEXNER MEDICAL CENTER

COMPANY OVERVIEW. July 30, 2018

RELEASED. first steps. Icon Icon name What it means

MINIMED 640G WITH SMARTGUARD GIVES YOU CONFIDENCE TO TAKE CONTROL OF YOUR DIABETES

DIABETES TECHNOLOGY: ENDLESS CHOICES FOR HEALTHY MANAGEMENT

Pump Basics for the School Nurse. Children's Endocrinology Center of Dallas

INSPIRED BY GIVE HIM MORE. The MiniMed 670G system is the world s first insulin delivery system that automatically adapts to your child s needs.

Insulin Pump Therapy. WakeMed Children s Endocrinology & Diabetes WakeMed Health & Hospitals Version 1.3, rev 5/21/13 MP

THE MINIMED 670G SYSTEM SCHOOL NURSE GUIDE

Company Overview February 26, 2019

INSPIRED BY GIVE HER MORE. The MiniMed 670G system is the world s first insulin delivery system that automatically adapts to your child s needs.

Abbott FreeStyle Libre Pro System

Continuous Glucose Monitoring (CGM)

Abbott FreeStyle Libre Pro System

COMPANY OVERVIEW. April 26, 2018

Today s Goals 10/6/2017. New Frontiers in Diabetes Technology. Disclosures

Diabetes Management: Current High Tech Innovations

Next steps for success.

Insulin Pump Therapy

Insulin Pump An information session to help you decide if you are ready to use an insulin pump.

Subject Index. Breastfeeding, self-monitoring of blood glucose 56

Continuous Glucose Monitoring

Welcome to CareLink Pro

DIABETES TECHNOLOGY: WHERE ARE WE NOW AND WHERE ARE WE GOING? Presented by: Tom Brobson

External Insulin Pumps Corporate Medical Policy

Animas Vibe System World-class insulin pumping meets world-class CGM*

CGM and Closing The Loop

ssociation of Children s Diabetes Clinicians Clinicians Continuous Glucose Monitoring (CGM) Training for Healthcare Professionals and Patients

Insulin Pump An information session to help you decide if you are ready to use an insulin pump.

Report Reference Guide. THERAPY MANAGEMENT SOFTWARE FOR DIABETES CareLink Report Reference Guide 1

Artificial Pancreas Device Systems

CONTINUOUS OR INTERMITTENT GLUCOSE MONITORING IN INTERSTITIAL FLUID

Technology in Diabetes Care: Emerging Level

Paolo Di Bartolo U.O di Diabetologia Dip. Malattie Digestive & Metaboliche AULS Prov. di Ravenna. Ipoglicemie e Monitoraggio Glicemico

Figure 2.1: Glucose meter

What is the role of insulin pumps in the modern day care of patients with Type 1 diabetes?

Calgary Diabetes Centre Insulin Pump Therapy: Preparation and Expectations

Continuous Glucose Monitoring (CGM)

THE ONLY SYSTEM^ CLINICALLY PROVEN TO REDUCE HYPOGLYCAEMIA

REPORT INTERPRETATION

Advances in Diabetes Technology Part II: Analysis of Diabetes Self Management Devices and Support Tools

More Than 1 Year of Hybrid Closed Loop in Pediatrics. Gregory P. Forlenza, MD Assistant Professor Barbara Davis Center

DISCLAIMER: ECHO Nevada emphasizes patient privacy and asks participants to not share ANY Protected Health Information during ECHO clinics.

First steps for success.

THERAPY MANAGEMENT SOFTWARE FOR DIABETES

Pumps & Sensors made easy. OPADA ALZOHAILI MD FACE Endocrinology Assistant Professor Wayne State University

Presented by Dr. Bruce Perkins, MD MPH Dr. Michael Riddell, PhD

BASICS OF INSULIN PUMPS. Jennifer Okemah MS RD BCADM CDE CSSD

WOULD YOU LIKE TO REDUCE THE FEAR OF HYPOGLYCAEMIA FOR YOUR PATIENTS?

CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS Annual Meeting HILTON HEAD ISLAND FRIDAY PRESENTATION

Advances in Diabetes Care Technologies

PROTOCOL FOR HYBRID CLOSED LOOP TECHNOLOGY

Medical Policy. MP Artificial Pancreas Device Systems

ASHLEY AUSTIN HEATHER MICHAELA RYAN. YOU CAN make managing diabetes easier.

Basics of Continuous Subcutaneous Insulin Infusion Therapy. Lubna Mirza, MD Norman Endocrinology Associates 2018

QUESTION 4. WHAT CLINICAL DATA ARE CURRENTLY AVAILABLE TO SUPPORT EXPANDED CGM COVERAGE BY PAYERS AS PERTAINS TO QUESTIONS 1 AND 3?

Real-Time Continuous Glucose Monitoring: From Application to Evaluation

Performance-powered. The OneTouch. Ping insulin pump and meter-remote.

PATIENT TRAINING CHECKLIST MINIMED 670G SYSTEM

Diabetes Medical Management Plan (DMMP)

Calgary Diabetes Centre Insulin Pump Therapy: Preparation and Expectations

Insulin Pumps - External

THERAPY MANAGEMENT SOFTWARE FOR DIABETES

DISCOVER THE POWER OF CONNECTION MINIMED 640G

Transcription:

Insulin Pump Therapy: Who, Why, and How Alyssa Kanagaki Greenleaf, BA, MHS, PA-C With new technology available to aid patients, diabetes management in the 21st century is moving beyond metformin. Among these advances are insulin pumps, which are not just for the young and tech-savvy. In fact, in 2016, the American Diabetes Association (ADA) revised their Standards in Medical Care to recommend patients 65 and older continue to use their insulin pumps and continuous glucose monitoring devices (CGMs), rather than forego technology for more traditional treatment options. 1 Insulin pumps enhance or mimic the role of the pancreas by providing a background, or basal, rate of insulin, as well as boluses for food or glucose corrections. A small catheter is inserted under the skin in the same areas used for injections (eg, arm, thigh, abdomen) to release insulin. 2 While the benefits of technology cannot always be quantified, there are data to suggest insulin pumps can reduce A1C by 1.1% in patients with type 2 diabetes. In tandem with CGMs, insulin pumps have been shown to be cost effective in those with a history of severe hypoglycemia. 3,4 QWhen should patients consider using an insulin pump? Patients with type 1 or type 2 diabetes can benefit from an insulin pump. In particular, they can be useful for patients who Are tired of multiple daily injections. Insulin is still bolused at mealtime just electronically. Require a tailored approach. Multiple basal settings can be programmed to reflect activity and work level; some patients need more insulin on active days and less on sedentary days. Have an on-the-go lifestyle. Insulin pumps replace multiple daily injections, as noted, which helps when patients miss manual injections due to accessibility issues. Value discretion. Those who wear restrictive uniforms for work or simply desire privacy may benefit from an insulin pump model that can bolus via remote control, without physical access to the pump. Have found other treatments suboptimal. Some insurers allow patients to try a pump before a decision is made. Experience hypoglycemia unawareness. Some pumps work with CGMs to suspend insulin delivery with a low glucose level; proper use of a pump can help to restore patient awareness of their condition. Are sensitive to insulin. Select pumps can deliver insulin at a rate of one-hundredth of a unit at a time. Experience the dawn phenomenon or Somogyi effect. Patients with high earlymorning glucose levels can adjust their rates to combat hyperglycemia, and those with overnight lows and rebounding hyperglycemia can adjust their basal rates or nighttime snacking settings to prevent this occurrence. QWho would be an ideal candidate? Motivated patients who want to attain glycemic control and adhere to the recommendations of their care team are ideally suited to insulin pump use. Insurance companies want to ensure patient safety, so before approving coverage for an insulin pump, they may require patients to demonstrate their willingness to adjust their lifestyle, work with their diabetes educator and/or provider team, and test routinely in the weeks or months leading up to the final decision all expected behavior while using pump therapy. continued on page 22 >> Alyssa Kanagaki Greenleaf practices at Baystate Endocrinology and Diabetes in Springfield, Massachusetts. The author reports no financial relationships relevant to this article. NOVEMBER 2017 Clinician Reviews 19

>> continued from page 19 QHow do you initiate insulin pump therapy? With any new treatment, clear communication is key. Patients should schedule specific appointments with their provider and diabetes team to know what is expected from both parties during this process. Pump selection should be individualized choice, depending on the patient s goals, lifestyle, and a thorough review of the pros and cons of each pump. When a selection has been made, patients can begin testing at least four times daily, before meals and at bedtime, as required by most insurers. Representatives from the pump s manufacturer can be a helpful resource for questions about the particular pump, as well as a liaison to the insurance company if clarifications are needed. Each practice is different, but once insurance coverage is determined, the patient may be asked to review his/her food log with the team. Those who count carbohydrates may be assessed for their ability to accurately measure and record this information, since it improves the accuracy of insulin boluses and effectiveness of treatment. Patients who do not count carbs should be advised of alternative options, such as capping meals at a certain carbohydrate amount (eg, 60 to 75 g, based on labels) or carbohydrate exchanges (eg, if a typical serving size is 15 g, patients may have 3 servings per meal). The comfort level of the practice and the care team, as well as the patient, may influence how pump therapy is initiated. Some care teams may decide to do a trial run with saline for safety, to ensure the patient is using the pump properly before advancing to insulin. QWhat are some features to consider when selecting a pump? The practical reality is that individual practices and providers are unlikely to offer every possible insulin pump; a practice may not have the software needed to download data from every type of pump. Patients must be comfortable with their choice of pump but so must providers. A clinician may be more familiar and/or comfortable with a particular pump (or pumps), based in part on his/her relationship with the manufacturer. If the provider feels sufficiently educated, he or she is better equipped to advise the patient on usage. Some of the insulin pumps available in the United States are described in the table. 5-11 te that there are many common features, such as 24-hour toll-free assistance hotlines; child button lockouts; full training; temporary basal rate options; programmable reminders; downloadable glucose data; low insulin warnings; low battery warnings; and user-set active insulin times. Other features vary and may influence a patient s choice of pump. These include color vs black-and-white screen (which can impact patients with impaired vision); tubeless versus insulin tubes; insulin cartridge size; compatibility and integration with CGMs; various degrees of water resistance; and hypoglycemia suspension. 12 QDoes insurance cover insulin pumps? Insurance coverage varies and may be offered on a case-by-case basis. Also, some insurers have preferred insulin pumps just as they have a preferred formulary. Some insurance companies may require patients to use multiple daily injections for at least six months prior to pump approval. Prior authorization for a pump trial (of a specific duration) may be required; after trial completion, another prior authorization may be needed before approval is granted. During the trial, the patient will need to demonstrate competency in selfmanagement with the pump, motivation to continue use, and commitment to making dietary and lifestyle changes. Some insurers may want to see A1C lowered to less than 7%, although this stipulation may be assessed by case, particularly in patients with risk factors for poor glycemic control (eg, recurrent hypoglycemia, severe hypogly- 22 Clinician Reviews NOVEMBER 2017

TABLE A Selection of Currently Available Insulin Pumps Pump (Manufacturer) Accu-Check Combo (Roche Insulin Delivery Systems) T:slim X2 (Tandem) 670G (Medtronic) OmniPod (Insulet Corp) Vibe (Animas d ) DANA Diabecare R (SOOIL Development) Insulin reservoir (U) Basal ranges (U/h) Bolus ranges (U) 315 300 180 or 300 200 200 300 0.05-25 0.1-15 0.025-35 0.05-30 0.025-25 0.04-16 0.1-25 0.01-25 0.025-25 0.05-30 0.025-35 0.05-80 Tubing? Yes Yes Yes Yes Yes Built-in continuous glucose monitor? a Dexcom Medtronic Dexcom Linking Yes Yes Yes Yes glucometer? b Touch screen? Yes Use with water c IPX 8 rating IPX 7 rating IPX 8 rating Pod: Waterproof to depth of 25 ft for up to 60 min Transmitter: t waterproof Watertight to 21 ft for 24 h IPX 8 rating Languages English, English English English, English, 21 different languages a Dexcom can be used with any pump. Medtronic has several different sensor models in use. b Linking means a device can talk to the pump without users having to manually enter glucose levels. c IPX 7 rating means that it is protected against water immersion for 30 min in 3 ft of water but not necessarily waterproof. IPX 8 means watertight in temporary immersion up to 60 min in 8 ft of water. d See Editor s te, page 24. Sources: Palinski-Wade E. Diabetes Forecast. 2017 5 ; Roche Diabetes Care, Inc. 2016 6 ; Tandem Diabetes Care. 2017 7 ; Medtronic. 2016 8 ; Omnipod. 2015 9 ; Animas. 2017 10 ; SOOIL Development Co, Ltd. 2017. 11 cemic episode, dawn phenomenon, large glycemic excursions, or pregnancy). Others will require patients to complete a comprehensive diabetes education program within two years prior to pump initiation. 13,14 For Medicare-qualified patients, pump supplies may not be covered; they may have to rely on supplemental insurance or switch therapies if insulin pump usage is not financially feasible. Under original Medicare, patients pay 20% of the Medicare-approved amount after the part B deductible for pump equipment (which is categorized as durable medical equipment). Medicare does pay for 80% of the insulin cost, but coverage can differ by case. 15 continued on next page >> NOVEMBER 2017 Clinician Reviews 23

>> continued from previous page QWhat are CGMs, and are they required? CGMs are small, external devices that sample glucose from the interstitial fluid using an electrode under the skin. The electrode transmits information to a display device, which can alert patients of patient-specific glucose values: if a high or low glucose value is reached; if the glucose value is predicted to change; or the rate of glucose value change. CGMs do not completely replace testing glucose levels, as they typically need to be calibrated two or more times throughout the day (though upcoming technology may reduce that to one or no calibrations). During calibration, patients manually check their glucose levels and enter readings into the CGM to ensure accuracy. CGMs are not required, but they can enhance a patient s insulin pump experience. Some CGMs talk directly with insulin pumps, so users do not have to manually input glucose levels. However, while there is even a CGM on the market that allows insulin dosing without a finger-prick, most sensors encourage patients to dose insulin based on manual glucose readings rather than CGM readings. A notable exception is a CGM talking to an insulin pump with a safety feature that can temporarily shut off the pump if low glucose levels are detected or predicted. 16-18 Q What are the latest advances in insulin pumps? In September 2016, the FDA approved Medtronic s hybrid closed-loop system for use by patients (ages 14 and older) with type 1 diabetes who use 8 U or more of insulin daily. This new insulin pump system, which uses a CGM, is sometimes referred to as an artificial pancreas. It tracks glucose levels every five minutes, increasing or decreasing basal insulin rates according to a glucose-based algorithm (though users still bolus at mealtimes by entering carbohydrates and calibrating their sensor). 19,20 Approval was based on results from a study of patients ages 14 to 75 with type 1 diabetes, which showed a reduction in A1C from 7.4% to 6.9%, without severe hypoglycemia or diabetic ketoacidosis. The percentage of patients in target range (defined as 70-180 mg/dl) increased from 66.7% at baseline to 72.2% at the end of the study. 21 Medtronic officially launched the device in June 2017. Other manufacturers are not far behind. Tandem is currently participating in an NIH-funded International Diabetes Closed Loop (IDCL) Trial of combined technology from Tandem Diabetes Care, Dexcom, and TypeZero (a software company). The company projects a launch date of late 2018 for their product. 22 Editor s te: At press time, Animas had announced that it will be discontinuing its insulin pumps in the United States. More information, including a transition plan for patients, is available at www.animas patientsupport.com. CR REFERENCES 1. American Diabetes Association. Standards of Medical Care in Diabetes 2016. Diabetes Care. 2016;39(suppl 1):S1- S112. 2. American Diabetes Association. Insulin pumps. www.diabetes.org/living-with-diabetes/treatment-and-care/medication/ insulin/insulin-pumps.html. 3. Aronson R, Cohen O, Conget I, et al; OpT2mis Study Group. OpT2mise: a randomized controlled trial to compare insulin pump therapy with multiple daily injections in the treatment of type 2 diabetes research design and methods. Diabetes Technol Ther. 2014;16:414-420. 4. Ly TT, Brnabic AJ, Eggleston A, et al. A cost-effectiveness analysis of sensor-augmented insulin pump therapy and automated insulin suspension versus standard pump therapy for hypoglycemic unaware patients with type 1 diabetes. Value Health. 2014;17(5):561-569. 5. Palinski-Wade E. Everything you need to know about insulin pumps. Diabetes Forecast. March/April 2017: Consumer Guide. www.diabetesforecast.org/2017/mar-apr/insulinpumps-101.html. 6. Roche Diabetes Care, Inc. ACCU-CHECK Spirit Combo User s Manual (2016). www.accu-chek.com/download/file/ fid/17481. 7. Tandem Diabetes Care. t:slim Insulin Pump User Guide (2017). https://www.tandemdiabetes.com/docs/defaultsource/product-documents/tslim-insulin-pump/updated-tslim-user-guide.pdf. 8. Medtronic. Using the Minimed 630G Insulin Pump (2016). www.medtronicdiabetes.com/sites/default/files/library/ download-library/workbooks/950m15270-011.pdf. Ac cessed October 2, 2017. 9. Omnipod. UST400 user guide: insulin management system (2015). www.myomnipod.com/patient_guide/ust400_user_ guide_en.pdf. 10. Animas. Diabetes training resources (2017). www.animas. com/diabetes-education-and-training/diabetes-resources. 11. SOOIL Development Co, Ltd. DANA Diabecare R (2017). http://sooil.com/eng/product. 24 Clinician Reviews NOVEMBER 2017

12. Integrated Diabetes Services. Top insulin pump comparisons (2016). http://integrateddiabetes.com/insulin-pumpcomparisons. 13. MassHealth. Guidelines for medical necessity determination for ambulatory infusion pumps (insulin pumps) (2011). www. mass.gov/eohhs/docs/masshealth/guidelines/insulinpump-guideline.pdf. 14. Anthem. Clinical UM Guideline (2017). www.anthem.com/ medicalpolicies/guidelines/gl_pw_a053532.htm. Accessed October 2, 2017. 15. Centers for Medicare & Medicaid Services. Your Medicare coverage: insulin pumps and supplies. www.medicare.gov/ coverage/infusion-pumps.html. 16. Dexcom. What is continuous glucose monitoring? (2017). www.dexcom.com/continuous-glucose-monitoring. Ac cessed October 2, 2017. 17. Medtronic. Continuous glucose monitoring (2017). www. medtronicdiabetes.com/treatments/continuous-glucosemonitoring. 18. Medtronic. SmartGuard low management suspend quick reference (2017). www.medtronicdiabetes.com/customersupport/minimed-670g-system-support/smartguardquick-reference. 19. FDA. FDA approves first automated insulin delivery device for type 1 diabetes [press release]. September 28, 2016. www.fda.gov/newsevents/newsroom/pressannounce ments/ucm522974.htm. 20. FDA. Medical devices: the 670G System - P160017 (2016). www.fda.gov/medicaldevices/productsandmedicalproce dures/deviceapprovalsandclearances/recently- ApprovedDevices/ucm522764.htm. Accessed October 2, 2017. 21. Bergenstal RM, Garg S, Weinzimer SA, et al. Safety of a hybrid closed-loop insulin delivery system in patients with type 1 diabetes. JAMA. 2016;316(13):1407-1408. 22. Tandem Diabetes Care. Innovations in progress (2017). www.tandemdiabetes.com/about-us/pipeline. Accessed October 2, 2017. NOVEMBER 2017 Clinician Reviews 25