The Growing Future of Diabetes: Insulin Pump Therapy in Type 1 and 2 Diabetes

Similar documents
Insulin Pumps and Continuous Glucose Sensors- Embracing Technology. Susan Cavalier, BS, RN, CDE Manager, Diabetes Educator Sanford Diabetes Education

MEDICAL POLICY Continuous Glucose Monitoring Systems and Insulin Pumps

Abbott FreeStyle Libre Pro System

Diabetes Technology Update. Sarah Konigsberg, MD Diabetes & Endocrine Assoc. April 7, 2018

DIABETES & ENDOCRINE DIABETES TECHNOLOGY: HOW TO STAY CURRENT WITH ONGOING TECHNOLOGY ADVANCEMENT

Abbott FreeStyle Libre Pro System

Approved by: Integrated Health Quality Management Subcommittee Effective Date: Department of Origin: Integrated Healthcare Services.

MEDICAL POLICY Continuous Glucose Monitoring Systems and Insulin Pumps

Diabetes and Technology. Saturday, September 9, 2017 Aimee G sell, APRN, ANP-C, CDE

Diabetes II Insulin pumps; Continuous glucose monitoring system (CGMS) Ernest Asamoah, MD FACE FACP FRCP (Lond)

NEW TECHNOLOGIES FOR MANAGING DIABETES ANGELA THOMPSON DNP, FNP-C, BC-ADM, CDE, FAANP

MEDICAL POLICY Continuous Glucose Monitoring Systems and Insulin Pumps

Updates in Diabetes Technology

Technology for Diabetes: 101 Basic Rules of the Road. Karen Hamon RN, BSN, CDE Stephen Stone MD, FAAP Neil H. White, MD, CDE

Continuous Glucose Monitoring (CGM)

Advances in Diabetes Care Technologies

INSPIRED BY GIVE HIM MORE. The MiniMed 670G system is the world s first insulin delivery system that automatically adapts to your child s needs.

INSPIRED BY GIVE HER MORE. The MiniMed 670G system is the world s first insulin delivery system that automatically adapts to your child s needs.

Today s Goals 10/6/2017. New Frontiers in Diabetes Technology. Disclosures

BASICS OF INSULIN PUMPS. Jennifer Okemah MS RD BCADM CDE CSSD

Advances in Diabetes Care Technologies

1. Continuous Glucose Monitoring

Predicts and helps prevent lows with. zero fingersticks NOW FEATURING BASAL-IQ TECHNOLOGY

10:20 AM March 5, B 100% 235 u. 124 mg/dl 3 HRS INSULIN ON BOARD:

Technology in Diabetes Care: Emerging Level

Objectives. The Problem. We ve come a LONG way, Innovations in Diabetes Care and Management. Barbara Walz, RN, BSN, CDE April 26, 2018

Advances in Technology in the Treatment of Diabetes Mellitus 2017 How far have we come-how far are we going? Is there a final frontier?

The Realities of Technology in Type 1 Diabetes

DIABETES TECHNOLOGY: WHERE ARE WE NOW AND WHERE ARE WE GOING? Presented by: Tom Brobson

WHEN YOUR PANCREAS IS NOT A HAPPY CAMPER A PRESENTATION ON DIABETES MANAGEMENT IN THE CAMP SETTING AMANDA COSCHI, BSCN, RN, CDE

For patients uncontrolled on multiple daily injections of insulin. A quick-start guide for your practice ALL-DAY CONTROL WITH

Corporate Medical Policy

COMPANY OVERVIEW. April 26, 2018

Control of Glycemic Variability for Reducing Hypoglycemia Jae Hyeon Kim

Subject Index. Breastfeeding, self-monitoring of blood glucose 56

Continuous Glucose Monitors for Diabetes Management

Pumps & Sensors made easy. OPADA ALZOHAILI MD FACE Endocrinology Assistant Professor Wayne State University

DISCLAIMER: ECHO Nevada emphasizes patient privacy and asks participants to not share ANY Protected Health Information during ECHO clinics.

DISCOVER THE POWER OF CONNECTION MINIMED 640G

COMPANY OVERVIEW. July 30, 2018

DISCOVER THE POWER OF CONNECTION MINIMED 640G

UNDERSTANDING THE BASIC FEATURES AND MANAGEMENT IN THE SCHOOL SETTING CHRISTINE HERTLER RN BSN CDE & MARY MCCARTHY RN CDE

Advances in Diabetes Technology Part II: Analysis of Diabetes Self Management Devices and Support Tools

Incorporating CGM Into Clinical Decision Making. Etie Moghissi, MD, FACE Clinical Associate Professor, David Geffen School of Medicine UCLA

Report Reference Guide

CONTINUOUS OR INTERMITTENT GLUCOSE MONITORING IN INTERSTITIAL FLUID

Designed with your patients lives in mind

Insulin Pump Therapy in children. Prof. Abdulmoein Al-Agha, FRCPCH(UK)

With new technology available to

Anneli, Martina s daughter In better control with her pump since 2011 MY CHILD HAS TYPE 1 DIABETES

RELEASED. first steps. Icon Icon name What it means

INSULIN INITIATION AND INTENSIFICATION WITH A FOCUS ON HYPOGLYCEMIA REDUCTION

Making the Most of Continuous Glucose Monitoring

Dexcom Current and Future Technology Innovations. Jorge Valdes Chief Technical Officer

CareLink. software REPORT REFERENCE GUIDE. Management Software for Diabetes

Animas Vibe System World-class insulin pumping meets world-class CGM*

CGM and Closing The Loop

Insulin Pump Therapy. WakeMed Children s Endocrinology & Diabetes WakeMed Health & Hospitals Version 1.3, rev 5/21/13 MP

Continuous Glucose Monitoring (CGM)

THE MINIMED 670G SYSTEM SCHOOL NURSE GUIDE

Advances in Diabetes Care Technologies

FAQs for HCP segment New Instructions for Dexcom G5 Mobile Continuous Glucose Monitoring (CGM) System Non-Adjunctive Indication

Real-Time Continuous Glucose Monitoring: From Application to Evaluation

First steps for success.

Policy and Procedure DEPARTMENT: Medical Management

Insulin Delivery and Glucose Monitoring Methods for Diabetes Mellitus: Comparative Effectiveness

Current Status: Retired PolicyStat ID: Effective: 03/2017 Approved: 03/2017 Last Revised: 03/2017 Expiration: 03/2020

Pump and Sensor Data Interpretation. Irl B. Hirsch, MD University of Washington School of Medicine

MEDICAL POLICY SUBJECT: CONTINUOUS GLUCOSE MONITORING SYSTEMS/ EXTERNAL INSULIN PUMP THERAPY FOR DIABETES EFFECTIVE DATE: 08/17/17

06/13/17. A. Completed a comprehensive diabetes education program within the past two years; and

OBJECTIVES THE PAST INNOVATIVE TECHNOLOGY & DIABETES DIABETES MIS MANAGEMENT IMPROVEMENTS IN DIABETES MANAGEMENT

5/16/2018. Integrating Diabetes Technology Into your Practice : Insulin Pump Therapy. Diosclosures. What exactly is an Insulin Pump?

External Insulin Pumps Corporate Medical Policy

Alternative Devices for Taking Insulin

Report Reference Guide. THERAPY MANAGEMENT SOFTWARE FOR DIABETES CareLink Report Reference Guide 1

GLOOKO DREAMED FOR ANDROID USER GUIDE

Pumping Insulin is it for your patients?

Continuous Glucose Monitoring

Clinical Value and Evidence of Continuous Glucose Monitoring

What is the role of insulin pumps in the modern day care of patients with Type 1 diabetes?

MEDICAL POLICY SUBJECT: CONTINUOUS GLUCOSE MONITORING SYSTEMS/ EXTERNAL INSULIN PUMP THERAPY FOR DIABETES EFFECTIVE DATE: 08/17/17, 08/16/18

MINIMED 640G WITH SMARTGUARD GIVES YOU CONFIDENCE TO TAKE CONTROL OF YOUR DIABETES

Basics of Continuous Subcutaneous Insulin Infusion Therapy. Lubna Mirza, MD Norman Endocrinology Associates 2018

Medtronic MiniMed Insulin Infusion Pumps

Diabetes Technology Continuous Subcutaneous Insulin Infusion Therapy And Continuous Glucose Monitoring In Adults: An Endocrine Society Clinical

Patrick J. Sullivan, President & CEO March 7, 2016 Raymond James 37 th Annual Institutional Conference

Diabetes Devices Workshop Angela Aldrich, PharmD, PhC April Mott, PharmD, PhC, BCPS Presbyterian Medical Group 28 January 2018

Company Overview February 26, 2019

NDSS Helpline

Insulin Pump Therapy

State of California Health and Human Services Agency Department of Health Care Services

Insulin Pump An information session to help you decide if you are ready to use an insulin pump.

Glucometers Gastrostomy Tubes Nasogastric Tubes Insulin pumps Continuous Glucose monitoring system Closed Loop Smart phones/tablets

Calgary Diabetes Centre Insulin Pump Therapy: Preparation and Expectations

Insulin Pumps - External

The pump that gets updated, not outdated. *

WOULD YOU LIKE MORE CONFIDENCE IN YOUR HYPOGLYCAEMIC CONTROL? SMARTGUARD. PROVIDES PREDICTIVE PROTECTION

COPYRIGHTED MATERIAL. Chapter 1 An Introduction to Insulin Pump Therapy WHAT IS INSULIN PUMP THERAPY?

V-Go : Simple to start, easy to use

Transcription:

The Growing Future of Diabetes: Insulin Pump Therapy in Type 1 and 2 Diabetes Sarah Dombrowski, PharmD, BCACP Pennsylvania Pharmacists Association 10/20/18 1

Objectives At the completion of this activity, the participant will be able to: Discuss current insulin pump and continuous glucose monitoring options for patients and identify appropriate patients for insulin pump therapy Describe pharmacists roles in insulin pump therapy across hospital, community and ambulatory care pharmacy Utilize insulin pump reports to assess blood sugar control and adjust patient pump settings when given a patient case 2

Insulin Pump Basics Electromechanical device that mimics the body s natural insulin secretion More physiologic than multiple daily injections (MDI) Pump holds and delivers the insulin Patient does not require injection of any insulin via needle/syringe Insulin lispro, aspart, and glulisine preferred (regular insulin possible) Delivers rapid-acting insulin in two ways: Preset continuous basal rates Boluses at mealtimes and as needed (manual) Infusion site to be changed every 3 days 3

Insulin Pump Basics 4

Diabetes Pump Outcomes Insulin pump therapy allows for better glucose control than MDI by Breaking insulin resistance and reducing insulin dose (esp. Type 2) In general, 20% reduction in TDD of insulin for patients switching from MDI to pump Improving blood glucose control and lowering A1c Limiting excess weight gain associated with MDI Reducing the frequency of severe hypoglycemia Especially when combined with continuous glucose monitoring Improving patient engagement in their diabetes management 5

Type 2 Diabetes Pump Outcomes Patient Feedback So happy I made the switch to pump so convenient and not sticking myself 5 times a day 6

Continuous Glucose Monitoring (CGM) Basics Device worn continuously by patient Needle or canula sits under patient s skin Glucose readings are taken from interstitial fluid Sensor glucose follows blood glucose Sensor and blood glucose readings will rarely match and are expected to be different A greater difference will be seen when glucose is changing quickly Provides continuous picture of glucose levels Must more data for patient and provider than fingersticks alone 7

CGM + Pump - Prevention of low blood sugars 8

Available Products Insulin Delivery and Continuous Glucose Monitoring 9

Current Continuous Glucose Monitor Options Medtronic ipro 2 with Enlite Sensor Dexcom G5 Mobile Dexcom G6 Medtronic Guardian Connect Medtronic Guardian Sensor 3 Freestyle Libre 10

Medtronic ipro 2 with Enlite Sensor Professional GCM placed by physician practice Used by physician to gather data on patients glucose levels Does not interface in real time with any device Tests glucose every 5 minutes Records glucose for up to 6 days Must be calibrated at least 2 times per day with fingersticks No predictive alerts or alerts for caregivers Worn on abdomen 11

Dexcom G5 Mobile Personal CGM Interfaces with Dexcom receiver, smart device Tests glucose every 5 minutes Needs to be changed every 10 days Does not require calibration with fingersticks For use in patients with Type 1 or 2 diabetes ages 2 yo and up Alerts for high or low glucose thresholds Includes alerts for up to 5 caregivers Worn on abdomen or upper buttocks (pediatric only) 12

Dexcom G6 Personal CGM Interfaces with Dexcom receiver, smart device, or insulin pumps (t:slim and Omnipod) Tests glucose every 5 minutes Needs to be changed every 10 days Does not require calibration with fingersticks For use in patients with Type 1 or 2 diabetes ages 2 yo and up Alerts for high or low glucose thresholds Includes alerts for up to 5 caregivers Worn on abdomen or upper buttocks (pediatric only) 13

Medtronic Guardian Sensor 3 Personal CGM Interfaces with Medtronic 670G pump Tests glucose every 5 minutes Needs to be changed every 7 days Must be calibrated 2-4 times per day with fingersticks For use in patients with Type 1 or 2 diabetes ages 14 and up on 670G insulin pump Predictive alerts 10-60 minutes before a low or high Does not include alerts for caregivers Worn on abdomen 14

Medtronic Guardian Connect Personal CGM Interfaces with Apple smart devices (Android interface in development) Tests glucose every 5 minutes Needs to be changed every 7 days Must be calibrated 2-4 times per day with fingersticks For use in patients with Type 1 or 2 diabetes ages 14-75 yo on insulin Predictive alerts 10-60 minutes before a low or high Includes alerts for caregivers Worn on abdomen 15

Freestyle Libre Personal CGM Interfaces with Freestyle Libre reader Tests glucose every 15 minutes Needs to be changed every 10 days Does not require calibrations with fingersticks For use in patients with Type 1 or 2 diabetes over 18 yo No alerts for lows/highs Does not include alerts for caregivers Worn on back of arm 16

Insulin pumps 17

Current Insulin Pump Options Omnipod Dash System Tandem t:slim X2 Medtronic 630G Medtronic 670G Hybrid Closed Loop System 18

Omnipod Dash 19

Tandem t:slim X2 20

21

22

Patient-Centered Approach to Insulin Pumps and CGMs 25

Pump Patient Selection Motivated to achieve normoglycemia Performs self-care responsibilities associated with diabetes Technical ability to monitor glucose and operate insulin pump Intellectual ability to learn and retain information Effective coping patterns Availability of support systems Financial resources to cover cost of therapy Adapted from the American Association of Diabetes Educators Position Statement on Education for Continuous Subcutaneous Insulin Infusion Pump Users. 26

Factors to consider in recommending a pump or CGM Patient age Type 1 versus Type 2 diabetes Current medication regimen Dexterity Cognition Body type Activity and occupation Insurance coverage Patient goals of care 27

Consider Differences in Pumps and CGMs Tubing versus tubeless Insertion site location Needle versus canula Angle of insertion for infusion set User interface Open loop versus hybrid closed loop systems Special technology features and communication with other devices 28

Customizability for Patient Delivery settings Basal Rates Carb ratio or fixed meal bolus Sensitivity factor Active insulin time Goal blood glucose range Differences in pump supplies (depends on the pump) Type of infusion set Length of tubing Length of canula Size of reservoir 29

Pharmacist Roles in Insulin Pump Management Across Healthcare Continuum 30

Hospital Pharmacists Consider pre-op recommendations Assess patient understanding and management of pump ISMP Safe Management of Patients with an External Subcutaneous Insulin Pump During Hospitalization Keep patient connected to pump when possible AACE and the ACE encouraged not to discontinue an insulin pump, but rather to consult specialist if the patient cannot manage his/her own pump Understand how to access delivery settings on patient s pump to determine insulin rates if need to transition to subcutaneous/iv insulin Ensure patient is able to restart pump upon discharge Change in settings? 31

Community Pharmacists Understand basics of insulin pumps and where to refer patients Assess patient understanding and compliance Patients should only be using short- or rapid-acting insulin in insulin pump Patient may have long-acting insulin and needles/syringes on hold for emergencies Ensure patient s prescription matches actual use Patient needs enough insulin in each fill for use + filling tubing and canula (if applicable) Help patient understand treatment of high and low blood sugars Partner with pump companies to improve patient access American Diabetes Association (ADA): CSII (continuous subcutaneous insulin infusion) should be prescribed, implemented, and followed by a skilled professional team familiar with CSII therapy and capable of supporting the patient. 32

Ambulatory Care Pharmacists Can take primary role in management in partnership with Endocrinology/Primary Care Monitor blood glucose and continuous glucose monitoring Adjust insulin pump settings (with Collaborative practice agreements) Train new pump patients (contract with company) Online and in clinic instruction Observe 1-2 trainings with company trainer Train 1-2 patients independently with trainer observation Pass written certification exam Staff education Opportunities for payment Face to face Telephonic/telemedicine? 33

Sample Reports and Patient Cases 34

Patient 1 35

Patient 2 36

Patient 3 37

Patient 4 38

Patient 5 39

Patient 6 40

Summary Current insulin pump and continuous glucose monitoring options for patients Appropriate patients for insulin pump therapy Pharmacists roles in insulin pump therapy Hospital Community Ambulatory care pharmacy Modification of pump settings to optimize patient outcomes 41

Questions? Sarah Dombrowski (skrahedombrowski@geisinger.edu) 42

References Boyd LC and Boyd ST. Insulin Pump Therapy Training and Management: An Opportunity for Community Pharmacists. J Man Care Pharm. 2008;14(8): 790-794. Reece SW, Hamby Williams CL. Insulin Pump Class: Back to the Basics of Pump Therapy. Diabetes Spectrum. 2014;27(2):135-140. Smetzer J (ed), Cohen M (ed), Shastay A (ed), et al. Safe Management of Patients with an External Subcutaneous Insulin Pump During Hospitalization. ISMP. Oct 20 2016;21(21):1-5. ISMP. Managing Hospitalized Patients with Ambulatory Pumps: Part 2- Recommendations for the Use of Insulin Pumps During Hospitalization. ISMP Medication Safety Alert. Oct 20 2016. https://www.ismp.org/resources/managing-hospitalized-patients-ambulatory-pumps-part-2- guidelines-use-insulin-pumps Insulin Pump Therapy Resources - Educator Tools Providing Guidance on Pump and Sensor Training. American Association of Diabetes Educators. https://www.diabeteseducator.org/practice/educatortools/ipt-resources 43

Product Sites (for healthcare professionals) https://professional.medtronicdiabetes.com/ https://provider.dexcom.com/ http://provider.myfreestyle.com/ https://www.myomnipod.com/healthcareproviders https://www.tandemdiabetes.com/providers 44