Supporting Information

Similar documents
Discrimination of Human Astrocytoma Subtypes by Lipid Analysis Using Desorption Electrospray Ionization Imaging Mass Spectrometry

Supporting Information

Utility of neurological smears for intrasurgical brain cancer diagnostics and tumour cell percentage by DESI-MS

Desorption Electrospray Ionization Coupled with Ultraviolet Photodissociation for Characterization of Phospholipid Isomers in Tissue Sections

Data Independent MALDI Imaging HDMS E for Visualization and Identification of Lipids Directly from a Single Tissue Section

MALDI Imaging Drug Imaging Detlev Suckau Head of R&D MALDI Bruker Daltonik GmbH. December 19,

Real time connection of Mass Spectrometry with Medicine and Surgery

Ozonolysis of phospholipid double bonds during electrospray. ionization: a new tool for structure determination

Nature Genetics: doi: /ng.2995

Sequence Identification And Spatial Distribution of Rat Brain Tryptic Peptides Using MALDI Mass Spectrometric Imaging

Three Dimensional Mapping and Imaging of Neuropeptides and Lipids in Crustacean Brain

Supplementary Information

Supplementary Figure 1 (previous page). EM analysis of full-length GCGR. (a) Exemplary tilt pair images of the GCGR mab23 complex acquired for Random

INTRODUCTION TO MALDI IMAGING

More structural information with MS n

PTM Discovery Method for Automated Identification and Sequencing of Phosphopeptides Using the Q TRAP LC/MS/MS System

The study of phospholipids in single cells using an integrated microfluidic device

Increased Identification Coverage and Throughput for Complex Lipidomes

High-sensitivity Orbitrap mass analysis of intact macromolecular assemblies. R. J. Rose, E. Damoc, E. Denisov, A. Makarov, A. J. R.

Characterization of Disulfide Linkages in Proteins by 193 nm Ultraviolet Photodissociation (UVPD) Mass Spectrometry. Supporting Information

Lipid and Metabolite Profiles of Human Brain Tumors by Desorption Electrospray Ionization - Mass Spectrometry

New Instruments and Services

REDOX PROTEOMICS. Roman Zubarev.

LOCALISATION, IDENTIFICATION AND SEPARATION OF MOLECULES. Gilles Frache Materials Characterization Day October 14 th 2016

Mass spectrometry-based intraoperative tissue identification in neurosurgery

Identification of Steroids in Water by Ion Trap LC/MS/MS Application

DNA methylation signatures for 2016 WHO classification subtypes of diffuse gliomas

Accel-Amplicon Panels

Essential Lipidomics Experiments using the LTQ Orbitrap Hybrid Mass Spectrometer

SUPPORTING INFORMATION. High Throughput Reaction Screening using Desorption Electrospray Ionization Mass Spectrometry

Case Presentation: USCAP Jason T. Huse, MD, PhD Assistant Member Department of Pathology Memorial Sloan Kettering Cancer Center

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

Characterization of an Unknown Compound Using the LTQ Orbitrap

Molecular pathology with desorption electrospray ionization (DESI) - where we are and where we're going

Phospholipid characterization by a TQ-MS data based identification scheme

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

Supporting information for: Memory Efficient. Principal Component Analysis for the Dimensionality. Reduction of Large Mass Spectrometry Imaging

Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification

SCS Mass Spectrometry Laboratory

LC/MS/MS SOLUTIONS FOR LIPIDOMICS. Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS

Rapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer

Application Note # FTMS-46 solarix XR: Analysis of Complex Mixtures

Technical Note # TN-31 Redefining MALDI-TOF/TOF Performance

An optical dosimeter for the selective detection of gaseous phosgene with ultra-low detection limit

Time (min) Supplementary Figure 1: Gas decomposition products of irradiated DMC.

Characterization of Noncovalent Complexes of Polyelectrolytes by Mass Spectrometry

Supplementary Figure 1

Supplementary Figure 1. IDH1 and IDH2 mutation site sequences on WHO grade III

The New WHO Classification and the Role of Integrated Molecular Profiling in the Diagnosis of Malignant Gliomas

Supplementary Online Content

Phosphorylated glycosphingolipids essential for cholesterol mobilization in C. elegans

New Instruments and Services

NGS in tissue and liquid biopsy

Detection of IDH1 mutation in human gliomas: comparison of immunohistochemistry and sequencing

Next-Generation Immunohistochemistry: Multiplex tissue imaging with mass cytometry

Agilent 7700x ICP-MS

Single-strand DNA library preparation improves sequencing of formalin-fixed and paraffin-embedded (FFPE) cancer DNA

Supporting information

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

Supplementary Figure 1. Sample preparation schematic. First (Stage I), square islands of MoO 3 are prepared by either photolithography followed by

Using Software Tools to Improve the Detection of Impurities by LC/MS. Application Note. Christine Miller Agilent Technologies.

iplex genotyping IDH1 and IDH2 assays utilized the following primer sets (forward and reverse primers along with extension primers).

Assessment performed on Friday, September 18, 2015, at Vancouver General Hospital

Visualization strategies for major white matter tracts identified by diffusion tensor imaging for intraoperative use

Supporting information for. Determination of sub nm levels of low molecular mass (LMM) thiols in natural waters by liquid

Supplementary information. Miniaturised 3D printed polypropylene reactor for online reaction. analysis by mass spectrometry

MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager

Supporting Information

IDH1 R132H/ATRX Immunohistochemical validation

A STABLE DICATIONIC SALT IN REACTIVE DESI-MS IMAGING IN POSITIVE ION MODE TO ANALYZE BIOLOGICAL SAMPLES DRAGOS LOSTUN

Small Molecule Drug Imaging of Mouse Tissue by MALDI-TOF/TOF Mass Spectrometry and FTMS

Mass Histology Service

Designer Fentanyls Drugs that kill and how to detect them. Cyclopropylfentanyl

Quantification with Proteome Discoverer. Bernard Delanghe

Application Note # MT-91. High Quality MALDI Imaging of Proteins and Peptides in Small Rodent Organ Tissues. Bruker Daltonics.

Characterizing invading glioma cells based on IDH1-R132H and Ki-67 immunofluorescence

Analysis of human biopsy specimens in a hospital by HR-MAS NMR Martial Piotto Bruker BioSpin France

(a) Significant biological processes (upper panel) and disease biomarkers (lower panel)

Molecular Testing in Lung Cancer

Detection, Confirmation, and Quantification of Chloramphenicol in Honey, Shrimp and Chicken Using the Agilent 6410 LC/MS Triple Quadrupole

MALDI Imaging Mass Spectrometry

Mass spectrometry imaging. What does MS imaging offer?

Supplementary Appendix

Supporting Information

Digitizing the Proteomes From Big Tissue Biobanks

Supplemental Figure 1. Intracranial transduction of a modified ptomo lentiviral vector in the mouse

Supporting Information

Agilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value

Supplementary Tables. Supplementary Figures

Identification and Quantitation of Microcystins by Targeted Full-Scan LC-MS/MS

SYNAPT G2-S High Definition MS (HDMS) System

Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices

Supporting information for

Corporate Medical Policy

Mass Spectrometry Course Árpád Somogyi Chemistry and Biochemistry MassSpectrometry Facility) University of Debrecen, April 12-23, 2010

Christoph Zuth, Alexander L. Vogel, Sara Ockenfeld, Regina Huesmann and Thorsten Hoffmann * S-1. Supporting Information for:

AVENIO family of NGS oncology assays ctdna and Tumor Tissue Analysis Kits

Introduction to the Oligo HTCS Systems. Novatia, LLC

Shotgun Proteomics MS/MS. Protein Mixture. proteolysis. Peptide Mixture. Time. Abundance. Abundance. m/z. Abundance. m/z 2. Abundance.

Multimodal Spectroscopic Tissue Scanner for diagnosis of ex vivo surgical specimens

Transcription:

Supporting Information Santagata et al. 10.1073/pnas.1404724111 Extended Description of Fig. 4A Intraoperative MS allows for significant advances in the frequency of intraoperative tissue sampling as well as improvements in time from tissue sampling to availability of tissue analysis that can influence intraoperative surgical decision making. The schematic in Fig. 4A shows standard-of-care practices including pre- and postoperative tests (including preoperative planning MRI, permanent surgical tumor pathology analysis, and genomic analysis of intraoperative tumor tissue samples). Also demonstrated is the intraoperative (i.e., surgical) workflow, including intraoperative MRI, frozen sectioning, and MS tissue analysis. All intraoperative time periods are drawn to scale according to the time required for each test. Currently, on a research basis, intraoperative MS analysis is typically completed within 2 min, whereas frozen section analysis is completed in 20 30 min and intraoperative MRI requires at least 60 min. The time course of each intraoperative analytical measurement is measured from the time that the tissue sample is taken from the brain of the patient (or the time that the patient is readied for MRI scanning) until information from the test can returned to the surgeon to help guide the remainder of the surgery. The MS analysis time points denote an example of the timing and frequency of representative sampling periods during an operation. MS time periods (hash-marked orange rectangles) connote that MS is not yet standard of care and is a research test. Tissue Samples All samples were obtained and analyzed under Institutional Review Board protocols approved at Brigham and Women s Hospital (BWH) and Dana Farber Cancer Institute. Informed written consent was obtained by neurosurgeons at BWH. Tumors were rereviewed and classified in accordance with the World Health Organization classification system by board-certified neuropathologists (S.S., K.L.L.). Resections of brain tumor lesions were performed using neuronavigation, with stereotactic mapping and spatial registering of biopsies performed. Threedimensional reconstructions of the tumor from MRI imaging data were achieved with the 3D Slicer software package. Gliobastoma xenografts BT116 and BT329 were derived from surgical resection material acquired from patients undergoing neurosurgery at the BWH on an Institutional Review Board-approved protocol. Briefly, tumor resection samples were enzymatically and mechanically dissociated using the MACS Brain Tumor Dissociation Kit (Miltenyi Biotech) to generate single-cell suspensions. Intracranial xenografts were generated by injecting 100,000 cells in the right striatum of SCID mice (IcrTac: ICR-Prkdcscid; Charles River Labs) and aged under standard conditions until onset of neurological symptoms. Killed xenografts were perfused by intracardiac injection of 4% paraformaldehyde and processed by standard methods for paraffin embedding. Histopathology and Immunohistochemistry. In addition to banked snap-frozen samples, all cases had tissue samples that were formalin-fixed and paraffin-embedded (FFPE). Sections of FFPE tissue were stained with an anti-isocitrate dehydrogenase 1 (IDH1)- R132H antibody (clone HMab-1 from EMD Millipore) as previously described. H&E-stained serial tissue sections were scanned using Mirax Micro 4SL telepathology system from Zeiss to generate digital optical images. Tumor content was evaluated by board-certified neuropathologists (S.S. and K.L.L.) through examination of H&E-stained tissue sections and IDH1 R132Hstained sections. Identification of 2-Hydroxyglutarate by Desorption Electrospray Ionization MS. The IDH1 status of each specimen was initially evaluated by immunohistochemistry (IHC) of a piece of FFPE tissue. For stereotactic cases, all biopsies were less than 0.4 cm and these specimens were divided into two [one portion was frozen for desorption electrospray ionization (DESI) MS studies and the other was processed for FFPE; the latter was used for IDH1 IHC]. To determine whether 2-hydroxyglutarate (2-HG) could be detected directly from glioma tissue sections by DESI MS imaging, we analyzed human glioma samples by DESI MS in the negative ion mode using either a linear trap quadrupole (LTQ) ion trap (Thermo Fisher Scientific) or an amazon speed ion trap (Bruker Daltonics). The solvent used in these experiments consisted of either MeOH:H 2 O (1:1) or ACN:DMF (1:1) with a mass from m/z 100 1,100. All experiments involving the amazon speed ion trap were carried out using a 5-kV spray voltage, 130 psi nebulizing gas (N 2 ), and a flow rate of 0.7 μl/min. Tandem MS analysis was used for identification of the molecular species at m/z 147.2. Further characterization was performed by tandem MS with an additional stage of MS analysis (MS 3 ). The standard compound L-α-hydroxyglutaric acid disodium salt (Sigma-Aldrich Inc.) was subjected to tandem MS experiments under the same conditions. Confirmation experiments were performed using a high-resolution LTQ Orbitrap mass spectrometer (Thermo Fisher Scientific). Further analysis was then conducted with the amazon speed ion trap. For this instrument, the 2-HG signal was located at m/z 146.9 and was assigned using a mouse brain that contained a large tumor with the 2-HG mutation. Tandem MS and MS 3 experiments were conducted on this peak to confirm its identity and found to be identical to the fragmentation pattern obtained with the LTQ instrument. Imaging of another mouse brain that had another tumor without the 2-HG mutation did not show this peak. A description of the samples used in this initial testing stage of this study (analyzed with the LTQ ion trap) is shown in Table S1. Negative ion mode DESI MS mass spectra of samples G23 and G31 are shown in Fig. 1, using MeOH:H 2 O (1:1) as the solvent system. In total, we analyzed 35 human glioma samples presented in Table S1, including oligodendrogliomas, astrocytomas, and oligoastrocytomas of different grades and varying tumor cell concentrations, using both ion trap mass spectrometers. Note that because tissue analysis by DESI MS is performed without sample preparation but directly on tissue section, standard quantification of 2-HG as commonly performed with timeconsuming HPLC-MS protocols is not possible. One means by which relative levels of a certain molecule can be calculated is by normalizing its signal to a reference signal or set of signals obtained from the sample. In our study, the total abundance of 2-HG signal at m/z 147 was normalized to the sum of total abundances of the most abundant lipid species detected from the glioma samples by DESI MS. The mass spectra were exported as nominal mass from Xcalibur software (Thermo Fisher Scientific), and the absolute intensities of the 40 most abundant lipid species within m/z 700 1,000, which had been previously identified by tandem MS, were summed. Noise or background peaks within that m/z range were not considered. Normalization was then accomplished by dividing the total intensity of 147 by the summed intensities of the lipid species. Note that because 1of9

a small contribution of background signal at the same m/z 147 was present in DESI mass spectra, MS 2 was performed for all samples to confirm the presence of 2-HG. This was especially important in some IDH1 mutant samples with low tumor cell concentrations and therefore much lower abundances of 2-HG in DESI mass spectrum. If the MS 2 fragmentation pattern matched that of authentic 2-HG, the sample was determined to be IDH1-mutated. Discrepancies in the fragmentation pattern or absence of detectable levels of m/z 147 were interpreted as IDH wild type by MS analysis. Results for DESI MS analysis were obtained using two solvent systems. Note that although the solvent system DMF:ACN (1:1) favored relative abundances of low m/z ions compared with MeOH:H 2 O, similar trends in 2-HG were observed for both solvents. Interestingly, the ratio of m/z 147 to the sum of lipid species correlated with the tumor cell concentration determined for the sample by histopathological evaluation of serial tissue section, providing a direct measure of the 2-HG levels in tissue. Most samples that were negative for IDH1 mutation as determined by IHC did not present 2-HG in the DESI MS mass spectra, even if the sample presented high tumor cell concentration, as confirmed by tandem MS analysis (with the exception of two samples as noted in the text). One of the challenges in the analysis was to determine IDH1 status by DESI MS detection of 2-HG in samples with low tumor cell concentration from full mass spectral data. For these samples, low detectable values of m/z 147 could be initially assumed as an indication of IDH negative mutation. Nevertheless, MS 2 and MS 3 of m/z 147 enabled IDH mutation status confirmation for these samples, despite the low tumor cell concentration (as low as 5% of tumor). DESI MS imaging was performed for a few of the samples analyzed to evaluate the distribution of 2-HG and other diagnostic lipid species compared with tumor cell distribution in tissue. Genetic Analysis Archival surgical specimens were reviewed by a pathologist (S.S.) to select the most appropriate tumor-enriched area for analysis. Total nucleic acid was extracted from FFPE tumor tissue obtained by manual macrodissection, followed by extraction using a modified FormaPure System (Agencourt Bioscience Corporation). Targeted mutational analysis (SNaPshot) of a panel of cancer genes that included IDH1 and IDH2 was performed. The primers listed below were used for targeted mutation analysis at codon R132 in IDH1 (nucleotide positions c.394 and c.395) and at codons R140 and R172 in IDH2 (nucleotide positions c.418, c.419, c.514 and c.515). PCR primers: IDH1 exon 4, 5 -ACGTTGGATGGGCTTGTGAGTGGATGGGTA-3 (forward) and 5 - ACGTTGGATGGCAAAATCACATTATTGCCAAC-3 (reverse); IDH2 exon 4a (to probe codon R140), 5 - ACGTTG- GATGGCTGCAGTGGGACCACTATT-3 (forward), and 5 - AC- GTTGGATGTGGGATGTTTTTGCAGATGA-3 (reverse); and IDH2 exon 4b (to probe codon R172), 5 - ACGTTGGATGAA- CATCCCACGCCTAGTCC-3 (forward), and 5 - ACGTTGGAT- GCAGTGGATCCCCTCTCCAC-3 (reverse). Extension primers: IDH1.394 extr 5 -GACTGACTGGAC- TGACTGACTGACTGACTGGACTGACTGACTGAGATC- CCCATAAGCATGAC-3, IDH1.395 extr 5 -TGATCCCCAT- AAGCATGA-3, IDH2.418 extr 5 -GACTGACTGACTGAC- TGACTGACTGACTGACTGACTGGACTGACTGACTGAC- TGCCCCCAGGATGTTCC-3, IDH2.419 extf 5 -GACTGA- CTGGACTGACTGACTGACTGAGTCCCAATGGAACTAT- CC-3, IDH2.514 extf 5 -GACTGACTGACTGACTGACTGA- CTGACTGGACTGACTGACTGACTGACTGGACTGACT- GACCCATCACCATTGGC-3, andidh2.515extr5 - GA- CTGACTGACTGACTGACTGACTGACTGACTGACTGG- ACTGACTGACTGACTGACTGGACTGACTGAGCCATGG- GCGTGC-3. 2of9

Fig. S1. Negative ion mode DESI mass spectrum from m/z 100 1,000 of (A) sample G31, a glioblastoma with wild-type IDH1. (B) Tandem mass spectrum of a low abundance ion detected at m/z 147 from sample G31 presents a fragmentation pattern that does not match that of standard 2-HG. Negative ion mode DESI mass spectrum from m/z 100 1,000 of (C) sample G23, an oligodendroglioma with the IDH1 R132H mutant shows high abundance of an ion at m/z 147.2. (D) Tandem mass spectrum of m/z 147.2 detected from sample G23 presents a fragmentation pattern that exactly matches that of standard 2-HG. 3of9

Fig. S2. Tandem mass spectra obtained from an α-ketoglutaric acid standard solution (m/z 144.8) in negative ion mode electrospray ionization using an amazon Speed ion trap [MS 2 of m/z 144.8 (A); MS 3 of the fragment m/z 101.0 (B)]. Fig. S3. Negative ion mode DESI mass spectra obtained in an LTQ Orbitrap mass spectrometer from m/z 100 1,000 for samples G42, an oligodendroglioma with the IDH1 R132H mutant with 2-HG signal at m/z 147.0299 (A) and G29 and a glioblastoma with wild-type IDH1 (B). (Insets) Zoomed-in region m/z 146.90 147.16. 4of9

Fig. S4. Normalization of 2-HG signal and estimation of limit of detection. In DESI MS analysis, a tissue section of 12 μm in thickness is examined on a pixelby-pixel basis, with sampling area of 200 200 μm 2 for each mass spectrum acquired. An estimation of the total amount of 2-HG per pixel can be made by first estimating the mass of a 10-6-mm human brain tissue section of 12-μm thickness to be 0.5 mg. The limit of detection of 2-HG was estimated by depositing different concentrations of standard 2-HG solutions onto mouse brain tissue, followed by DESI MS analysis under the same experimental conditions as for the human glioma samples analysis. (A) A correlation factor of (R 2 = 0.69) was determined when directly plotting the m/z 147 signal versus the known 2-HG concentration, (B) but a somewhat linear relationship was observed between the m/z 147 normalized to the sum of the 40 most abundant lipid species and the known 2-HG concentration (R 2 = 0.94) from the mouse brain tissue by DESI MSI. Note that the correlation in both plots is significantly improved if the concentration range is limited to 100 μmol/g. The limit of detection was estimated to be 3 μmol 2-HG/g of tissue. Fig. S5. Bar plot of normalized 2-HG signal versus tumor in a glioma series with IDH1 mutation (see Table 1 for sample details). Blue bars, low tumor cell concentration; red bars, high tumor cell concentration. A, astrocytomas; O, oligodendrogliomas; and OA, oligoastrocytomas. 5of9

Fig. S6. Two-dimensional DESI MS ion images of human glioma cell xenografts in immunocompromised mice. (A) Negative ion mode 2D DESI MS images of human glioblastoma xenograft (BT329) that has wild-type IDH1 and (B) human glioblastoma xenograft (BT116) that has an IDH1 R132H mutation. The left panel is an ion map demonstrating the relative signal intensity of peak m/z 146.9, which was confirmed to be 2-HG by tandem MS analysis (MS 2 and MS 3 ). Relative signal intensity (0 100%) is plotted for each specimen using a color scale. Low magnification and high magnification light microscopy images of H&Estained sections are shown, and IDH1 R132H point mutation specific antibody staining on the far-right panel. (Scale bar, 100 μm.) Fig. S7. Two-dimensional DESI MS ion images of human glioma resection specimen. Negative ion mode 2D DESI MS images from glioma resection specimens with IDH1 mutations. G30 (A-IV-O). (Left) An ion map demonstrating the relative signal intensity of peaks at m/z 146.7 147.2, which were each confirmed to be 2-HG by tandem MS analysis (MS 2 ). MS data for sample G30 was acquired using an LTQ ion trap (Thermo Fisher Scientific). Relative signal intensity (0 100%) is plotted for each specimen using a color scale. Low magnification light microscopy images of H&E-stained sections show the tissue outline. The red boxed area indicates a region of higher tumor cell concentration. The black boxed area indicates blood. 6of9

Fig. S8. Three-dimensional mapping of 2-HG over MRI volume reconstruction for surgical case 13, an oligoastrocytoma grade II. (A) Normalized 2-HG signal is represented with a warm color scale as indicated by the scale bar, set from the lowest to highest levels detected from this individual case. MS data were acquired on a DESI AmaZon Speed instrument. Stereotactic positions were digitally registered to the preoperative MRI using neuronavigation (BrainLab system) in the Advanced Multimodality Image Guided Operating (AMIGO) suite. (B) High magnification microscopy images of an H&E-stained section of FFPE tissue from sample S56 showing high tumor cell concentration (Upper) and of IHC for IDH1 R132H mutant (Lower). (C) 2-HG over tumor volume reconstruction from the T2-weighted intraoperative MRI. (Inset) The residual lesion. (D) High magnification microscopy images of H&E-stained sections of FFPE tissue from sample S60 showing the presence of residual tumor cells (Upper) and of IHC for IDH1 R132H mutant (Lower). (Scale bar, 100 μm.) Fig. S9. (A) IHC using an IDH1 R132H point mutation-specific antibody on an FFPE section from oligoastrocytoma grade II samples (S75). (Scale bar, 100 μm.) (B) Targeted mutational profiling using SNaPshot analysis on nucleic acids extracted from oligoastrocytoma grade II archival specimens (S75). The arrow points to the IDH1 R132G (c.394c > G) mutant allele. The assayed loci were as follows: (1) KRAS 35, (2) EGFR 2236_50del R, (3) PTEN 517, (4) TP53 733, (5) IDH1 394, (6) PIK3CA 3139, (7) NOTCH1 4724, and (8) NOTCH1 4802. (C) High magnification light microscopy images of H&E-stained swab (Left), smear (Center), and frozen tissue section (Right) are shown. (Scale bar, 200 μm.) (D) Corresponding tandem mass spectra (MS 2 )ofm/z 147.0 (Left), 146.9 (Center), and 146.9 (Right) detected from sample S72 present a fragmentation pattern that exactly matches that of standard 2-HG. 7of9

Fig. S10. (A) High magnification light microscopy images of H&E-stained smear (Left) and frozen tissue section (Center) of sample S92 are shown. (Scale bar, 200 μm.) IHC (Right) using an IDH1 R132H point mutation-specific antibody on an FFPE section from an oligoastrocytoma grade III sample (S92). (Scale bar, 20 μm.) (B) Normalized 2-HG signal for samples of case 28, an oligoastrocytoma grade III represented with a warm color scale as indicated by the scale bar, set from the lowest (yellow) to highest (red) levels detected from samples for this individual case. Stereotactic positions were digitally registered to the preoperative MRI using neuronavigation (BrainLab system) in a standard operating room. The 3D tumor volume is shown (Upper). Classification results of samples S98, S92, and S95 are further visualized on axial sections (Lower). (Insets) Negative ion mode 2D DESI MS images of 2-HG peak for smears of samples S98, S92, and S95. Brain shift after the craniotomy has resulted in sample S92 s being mapped to the surface of the brain and S95 to just slightly outside of the brain. (C) Negative ion mode DESI mass spectra obtained using an amazon Speed ion trap from m/z 130 165 (Bruker Daltonics) from a smear (Left) and a section (Right) for sample S92. (D) Corresponding tandem mass spectra (MS 2 and MS 3 )ofm/z 146.7 and 128.8 (smear, Left) and (section, Right) detected from sample S92 present a fragmentation pattern that exactly matches that of standard 2-HG. 8of9

Table S1. Detailed description of samples used in IDH1 study Sample ID Diagnosis % tumor IHC IDH1 R132H Normalized m/z 147 2-HG Low tumor cell concentration G10 O-II 30 Positive 12 Positive G22 O-II 10 Positive 9 Positive G25 O-II 20 Positive 72 Positive G40 O-II 5 Positive 45 Positive G13 OA-II 5 Positive 11 Positive G14 OA-II 40 Positive 47 Positive G9 O-II/III 50 Positive 44 Positive G11 O-II/III 20 Positive 79 Positive G20 OA-III 30 Positive 16 Positive G26 A-IV 20 Positive 52 Positive G47 A-IV-O 5 Positive 30 Positive High tumor cell concentration G2 A-II 60 Positive 74 Positive G49 O-II 100 Positive 87 Positive G42 O-II 90 Positive 148 Positive G43 O-II 80 Positive 241 Positive G41 O-III 95 Positive 178 Positive G23 O-III 95 Positive 215 Positive G21 OA-III 95 Positive 247 Positive G45 OA-III 100 Positive 79 Positive G30 A-IV-O 80 Positive 48 Positive G46 A-IV 90 ND 62 Positive IDH wild type by IHC G3 A-III 60 Negative 10 Negative G4 A-III 30 Negative 6 Negative G5 A-IV-O 80 Negative 29 Negative G6 A-IV 80 Negative 12 Negative G8 A-IV 90 Negative 10 Negative G27 A-IV 95 Negative 16 Negative G28 A-IV 80 Negative 126 Positive G29 A-IV-O 80 Negative 25 Negative G31 A-IV 90 Negative 17 Negative G32 A-IV 90 Negative 15 Negative G33 A-IV 80 Negative 41 Positive G34 A-IV 30 Negative 8 Negative G35 A-IV 80 Negative 36 Negative G48 A-IV 90 Negative 21 Negative IHC and DESI results are shown. ND, not determined. 9of9