AA-M1C1. Audiometer. Space saving is achieved with a width of about 350 mm. Audiogram can be printed by built-in printer

Similar documents
TWO CHANNEL CLINICAL AUDIOMETER AUDIOSTAR PRO

Oscilla - excellence since 1960

AUDIOLAB Two channel clinical audiometer. Tonal Audiometry Vocal Audiometry MASKING SISI ABLB Decay Test BEKESY

OIML R 122 Annex C RECOMMENDATION. Edition 1999 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

Diagnostic Audiometer

GSI AUDIOSTAR PRO CLINICAL TWO-CHANNEL AUDIOMETER

INTRODUCTION TO PURE (AUDIOMETER & TESTING ENVIRONMENT) TONE AUDIOMETERY. By Mrs. Wedad Alhudaib with many thanks to Mrs.

AD226 Diagnostic Audiometer

UNITY 2. a state-of-the-art audiological integrated diagnostic and fitting system

AC40 Technical Specificatons Page 1. Technical Specifications AC40. Clinical Audiometer

FONIX FP35. Ease and Accuracy with the FP35 Touch Hearing Aid Analyzer! Visible Speech

Operating Instructions MA 52

Organisation Internationale de Métrologie Légale

AC40 Technical Specificatons. Technical Specifications AC40. Clinical Audiometer D F 2017/11

AUDIOMETERS AUDIXI 10

AMBCO 1000+P AUDIOMETER

General about Calibration and Service on Audiometers and Impedance Instruments

FONIX FA-12 Hearing Evaluator Digital Audiometer

AMBCO AUDIOMETER

AC40. Clinical Audiometer. Save time Focus on results. Interacoustics. l e a d i n g d i a g n o s t i c s o l u t i o n s

MA 40 Operating Instructions

Audiology Equipment p r o d u c t s c AtA l o g u E

AMBCO 2500 AUDIOMETER SYSTEM WITH FIVE YEAR WARRANTY

Operating Instructions MA 41

Testing Digital Hearing Aids

ER75 Electro-Acoustic Ear Simulator. Operating Manual

AA222 / AA220. Audio Traveller. Save time on routine. Focus on results. Interacoustics. leading diagnostic solutions

Equinox 2.0. PC-based audiometer. Time saving solutions. Interacoustics. leading diagnostic solutions

SHOEBOX Audiometry Pro. User Guide

MA 25 Operating Manual

User Manual. - Pro Edition -

User Manual. - Pro Edition -

Operation Manual MA 41

EPIC-PLUS System for auditory evoked potentials and neuro-otology. PEA - VEMPs ASSR - E-ABR FACIAL NERVE

AD629 The true hybrid

SHOEBOX Audiometry Pro. User Guide. Think Outside of the Booth!

PC BASED AUDIOMETER GENERATING AUDIOGRAM TO ASSESS ACOUSTIC THRESHOLD

The true clinical hybrid audiometer Stand alone & PC-based audiometry in one box. Interacoustics. Clinical Audiometer AC40.

Contents. QuickSIN.. 15 Hearing Loss Simulator Master Hearing Aid Printing Limited Warranty.. 20 #0086.

Product Model #: Digital Portable Radio XTS 5000 (Std / Rugged / Secure / Type )

Glossary For Parents. Atresia: closure of the ear canal or absence of an ear opening.

GSI 61 CLINICAL TWO-CHANNEL AUDIOMETER

This Page Left Intentionally Blank

GRASON-STADLER HEARING ASSESSMENT SYSTEMS

Diagnostic Impedance & Audiometry in one solution

SOFTWARE INSTRUCTION MANUAL

The true clinical hybrid audiometer. Interacoustics. Clinical Audiometer AC40. Stand alone & PC-based audiometry in one box.

Operating Instructions MA 25

myaudiometer. It s familiar, and it s so much

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard

COPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN ISO :1998

Operating Instructions MA 33

Healthy Organ of Corti. Loss of OHCs. How to use and interpret the TEN(HL) test for diagnosis of Dead Regions in the cochlea

This Page Intentionally Left Blank

Bone conduction hearing solutions from Sophono

PERIPHERAL AND CENTRAL AUDITORY ASSESSMENT

Recommended Procedure. Industrial Audiometry

Recommended Procedure. Industrial Audiometry

SHOEBOX Audiometry Standard. User Guide

Software Training Manual

THE MECHANICS OF HEARING

The true hybrid Stand alone & PC-based audiometry in one box

TRAINING MANUAL. AVANT Air, Bone, Speech and Masking Audiometry AUDIOMETERS.

Beltone Electronics 2601 Patriot Boulevard Glenview, IL U.S.A. (800)

AC40. The true clinical. hybrid

The true hybrid Stand alone & PC-based audiometry in one box

AT235/AT235h Middle Ear Analyzers. Diagnostic & clinical tympanometry with basic audiometry.

GSI AMTAS AUTOMATED AUDIOMETRY. Setting The Clinical Standard

OAE Test System. Screener PLUS. Diagnostic PLUS. with 4 frequency DPOAE testing Protocols

Equinox 2.0 PC-based audiometer. Not just an audiometer - A full counseling and reporting solution

TRAINING MANUAL AVANT ARC. Audiometry & Binaural REM/LSM in One System.

User groups Most sensorineural, conductive and mixed hearing losses in the categories of severe and profound.

What s New in Primus

MADSEN Xeta. Reference Manual. Doc. No EN/16 Part No EN

Product Model #:ASTRO Digital Spectra Consolette W7 Models (Local Control)

TRAINING MANUAL. AVANT The Perfect Screening Audiometer AIR+

Matrix sentence test (Italian)

ALL INDIA INSTITUTE OF SPEECH AND HEARING, MYSURU E-PROCUREMENT NOTIFICATION FOR SUPPLY OF

Re/Habilitation of the Hearing Impaired. Better Hearing Philippines Inc.

MA 39 Operating Instructions

Recommended Procedure. Pure-tone air-conduction and boneconduction threshold audiometry with and without masking

Testing FM Systems on the 7000 Hearing Aid Test System

ERO SCAN. OAE Test System. Screener. Diagnostic. with 4 frequency DPOAE testing Protocols

The registration testing for audiometric device in CFDA

Cochlear Baha 4 Fitting Software 4.0 Desk Reference

ERO SCAN. Otoacoustic Emission Testing

The true hybrid Stand alone & PC-based audiometry in one box

Signals, systems, acoustics and the ear. Week 1. Laboratory session: Measuring thresholds

Additional Information. PC-based Audiometer Equinox 2

CITY OF FORT BRAGG HEARING CONSERVATION PROGRAM

Hearing Conservation Services Specifications

HEARING CONSERVATION PROGRAM

SHOEBOX Audiometry Pro. Quickstart Guide. SHOEBOX Audiometry Pro

Good Things Come In Small Packages. Diagnostic & Hearing Instrument Fitting Technologies CATALOG

Neuro-Audio Version 2010

Hearing Aids. Bernycia Askew

ENZO 3D First fitting with ReSound Smart Fit 1.1

Transcription:

Audiometer AA-MC Ideal for clinical practice in otolaryngology clinic Space saving is achieved with a width of about 350 mm Easy operation with touch panel Audiogram can be printed by built-in printer

AA-MC It is the most suitable audiometer for clinical practice in otolaryngology clinic. It can be used for hearing threshold test at clinics and hearing screening test at medical checkup institutions. Features AA-MC has necessary inspection functions at clinical site such as pure-tone audiometry, above-threshold test and Bekesy audiometry. Pure-tone audiometry (manually and automatically) can be used for diagnosis as well as medical checkup. Bone conduction test can be performed at forehead or mastoid. Talk over and talk back functions are available. (Microphone is separately necessary.) Size down to save space The width is 5.7% smaller than that of our previous audiometer (AA-79). Easy operation with touch panel The settings and ID input can be operated by touch panel. Width reduction by 5.7% (-6.5 cm) Warning display function Warning display The background of the output display turns yellow in the level of 80 db or more and turns red in the level of 00 db or more. Indication lamp The indication lamp lights in orange at a level of 80 db or more, and red at a level of 00 db or more. Equipped with LAN interface Test data can be transferred to computer via the LAN interface.

Pure-tone Audiometry Tests can be performed manually or automatically. Automatic plateau method or fixed masking method can be used for automatic test. The average hearing level is automatically calculated by three-frequency average, four-frequency average and six-frequency average. User can enter UCL on the audiogram. Audiogram Printing example Audiogram Hearing tests for health examination For the health checkup at schools, companies and others, hearing tests with this audiometer can be performed. Screening test The test can be performed manually or automatically. Threshold test The test can be performed manually or automatically. The test results are displayed numerically in the threshold table

AA-MC Speech Audiometry The level for the SRT (speech-reception threshold) test can be set to decrease 5 or 0-dB step automatically. With the talkback function, operator can listen to the subject's voice and presentation words with the monitoring earphones. Speech audiogram Threshold upper hearing test SISI test Short Increment Sensitivity Index test The test progress can be checked on the screen. ABLB test Alternate Binaural Loudness Balance test Operator can interchange the impaired ear and the good ear on the condition setting screen.

Bekesy Audiometry TTS test Test can be performed in 3 minutes or 6 minutes per frequency. Up to 4 frequencies can be recorded. Fixed-frequency Bekesy Test results of right and left ear for six frequencies of 250 8000 Hz can be recorded separately. Connection with computer PC By linking with PC software (option), the test results can be stored and printed out anytime. Audiogram can be transferred to RION fitting software.

Audiometer AA-MC Specifications Test functions Test item: Pure-tone audiometry Air conduction: Standard Bone conduction: Mastoid (open), Forehead (occluded) Screening test Air conduction Above threshold test SISI Test, ABLB Test Bekesy audiometry TTS test, Fixed-frequency Bekesy Speech test External input Pure-tone Audiometry Pure tone frequency Air conduction: 25, 250, 500, 750, 000, 500, 2000, 3000, 4000, 6000, 8000 Hz Bone conduction: 250, 500, 750, 000, 500, 2000, 3000, 4000, 6000, 8000 Hz Pure tone level range Air conduction: -0 to 0 db HL (maximum) Bone conduction: -0 to 70 db HL (mastoid open / no correction, maximum) Output level Reference equivalent threshold sound pressure levels of air condition earphone conform to JIS T 20-:20. Reference equivalence threshold force levels of bone vibrator conform to JIS T 20-: 20 Output of bone conduction can be output with the following combination depending on the placing site and compensation for the effect of the ear canal occlusion; Mastoid open / no compensation, forehead occluded / no compensation, forehead occluded / with compensation. Frequency error: For each frequency ±2% Output level error: Air conduction: 25~4000 Hz ±3 db 6000, 8000 Hz ±5 db Bone conduction: 250~4000 Hz ±4 db 6000, 8000 Hz ±5 db Hearing level scale: 5 db step Total harmonic distortion: Air conduction: 2.5% or less Bone conduction: 5.5% or less Interrupter: Intermittent frequency: 2.2Hz Fixed, Operation reversible Rise and fall time: 40 ms Masking noise (common to tests other than the speech test) Band noise for masking: According to JIS T 20-:20 Narrow band noises (/2.5 octave band width) Band noise Center frequency 25,250,500,750,000,500,2000,3000,4000,6000,8000 Hz Masking noise level range: Band noise: 0 to 05 db HL (maximum) Masking noise level scale: 5-dB step Average hearing level: Automatic display and printing (3-frequency, 4-frequency and 6-frequency average) Automatic threshold test Masking method: Automatic Plateau and Fixed masking Screening test Test frequency and test tone level Frequency 000 Hz 4000 Hz Test tone level 30 db fixed 30 db or 40 db Above threshold test SISI test SISI test tone incremental level: db (Training and Checking: 5 db) Tone incremental period: 5 seconds Display and record the response patterns up to 4 frequencies for left and right ear. The response pattern and SISI score are printed. ABLB test Test frequency and level range: Same to the pure tone output range (Air conduction only). However, the minimum output level in the masking noise level dial is 0 dbhl. Displays and records test results up to 4 frequencies Interchangeable the right and left ear on the screen display (impaired ear / good ear) Bekesy Test frequency Fixed frequency self-check (air conduction only): Select from 6 frequencies of 250, 500, 000, 2000, 4000, 8000 Hz TTS test (air conduction only): Select from frequencies from 25 to 8000 H Frequency direction sweep rate: 0.5,, 2 octave / min (Fixed Bekesy) scale / minute, Fixed (TTS) TTS test time: TTS Test results: 3.6 minutes / frequency Up to 4 patterns can be recorded Speech hearing test Test sound source: External input Hearing level measurement range: -0 to 00 db (air conduction only) Masking noise Speech noise: According to JIS T 20-2: 2000, Weighted random noise Level range: 0 to 00 db HL Digital section Interface RS - 232 - C: Display unit: Built-in printer: Others Data output LAN: Data output and input 7 inch wide color LCD, 800 x 480 dot, resistance film touch panel 4-inch thermal printer, 832 dots / line, 8 dots / mm Talk over: Can be used by connecting an optional microphone Talkback: Can be used by connecting an optional microphone (Output to the right channel of monitor earphone) Built-in alarm: Ringing in the completion of the test, confirmation and the abnormality, ON / OFF switchable Other functions: External alarm, internal clock Power supply Power supply: Voltage marked as panel, 50/60 Hz, 60 VA Electrical shock protection: Class, Type B Ambient conditions Ambient conditions for use: 5 to 35 C, 30 to 90 % R.H. (without condensation) Ambient conditions for transportation and storage: -0 to 50 C, 0 to 90 % R.H. (without condensation) Dimensions and Weight 350 (W) x 395 (D) x 290 (H) mm, 5.8 kg Accessories Earphone with cord for air Headband for Bone vibrator BR-4 EB-02 AD-02BF conduction audiometry Patient response switch PO-02F Bone vibrator BR-4 Monitoring earphone (stereo type) 4EHD2440 Cord for Bone vibrator Headband for air conduction audiometry EB-53BF EB-30 Power cord Thermal recording paper Recording paper axis Fuse AA-38-222 TP-42 AA-M-025 028002.MXP 2 2 Specifications subject to be changed without notice Made in Japan Distributed by: URL: http://www.rion.co.jp/english 3-20-4, Higashimotomachi, Kokubunji, Tokyo 85-8533, Japan Telephone: +8-42-359-7862 Fax: +8-42-359-7457 20709