Cardiovascular magnetic resonance with an MR compatible pacemaker

Similar documents
MRI conditional devices. A luxury or a real clinical need? Sophie Mavrogeni, MD, FESC Onassis Cardiac Surgery Center, Athens, Greece

MRI and CIEDs. Disclosures

EXAMPLE PROTOCOL FOR PATIENT SCANNING PROCESS

Call Medtronic at 1 (800) to verify the patient s current implanted system

Managing Metallic Artifacts in MRI

MRI SureScan pacemakers & ICDs what you need to know

Micra MC1VR01. MRI procedural information for Micra Model MC1VR01 MR Conditional single chamber transcatheter pacing device (VVIR)

STANDARD OPERATING PROCEDURE (SOP)

Advisa MRI and Ensura MRI SureScan pacing systems

CARDIAC MRI. Cardiovascular Disease. Cardiovascular Disease. Cardiovascular Disease. Overview

MRI SURESCAN SYSTEMS. Patient Scanning Process PATIENT PRESCREENING. SureScan Pacing, Defibrillation, and CRT-D Systems Verification

Devices and EP- Safety in MRI

MRI imaging for patients with cardiac implantable electronic devices (CIEDs)

MRI ACCESS. Evera MRI SureScan ICD Systems

CARDIAC DEVICE MR-CONDITIONAL PRODUCT SUMMARY CHART

MRI for Patients with MRI-Conditional Pacing System: Radiographers Role. Lawrance Yip DM, DR, QMH

Supplemental Material

Safety and Imaging Quality of MRI in Pediatric and Adult Congenital Heart Disease Patients with Pacemakers

Q & A: How to Safely Scan Patients with a SureScan MRI Pacemaker

MRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System

Perioperative Management of Cardiac Implantable Devices

Puzzling Pacemakers Cheryl Herrmann, APN, CCRN, CCNS-CSC-CMC

Pediatric pacemakers & ICDs:

CVIA. Cardiac Implantable Electronic Devices and Magnetic Resonance Imaging INTRODUCTION

MEDTRONIC CARELINK NETWORK FOR PACEMAKERS. Comparison between the Medtronic CareLink Network for Pacemakers and Transtelephonic Monitoring

Magnetic resonance imaging of pacemakers and implantable cardioverter-defibrillators without specific absorption rate restrictions

MRI in Patients with Pacemakers and Defibrillators. Paul A. Friedman, MD Win K Shen, MD Robert E. Watson, Jr. MD, Phd October 2016

MRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System

12 th International Winter Arrhythmia School Collingwood, Ontario February 7, Dr. Derek Yung. MD, FRCPC

Revo MRI Pacing System

Device Interrogation- Pacemakers, ICD and Loop Recorders. Dulce Obias-Manno, RN, MHSA, CCDS,CEPS, FHRS Device Clinic Coordinator, MHVI

Clinical Data Summary: Avoid FFS Study

*smith&nephew. MRI Safety Information & Parameters for Smith & Nephew Orthopaedics AG. Knee Implants

PERMANENT PACEMAKERS AND IMPLANTABLE DEFIBRILLATORS Considerations for intensivists

Protocol. This trial protocol has been provided by the authors to give readers additional information about their work.

MRI Guidelines for the Axonics Sacral Neuromodulation System

PACING SYSTEMS.

Safe magnetic resonance image scanning of the pacemaker patient: current technologies and future directions

09/05/2018. True/False: All pacemakers have defibrillation capabilities.

*smith&nephew. MRI Safety Information & Parameters for Smith & Nephew Orthopaedics AG. Shoulder Implants

MRI Exams in Patients with Non MR Conditional Pacemakers and with MR Conditional Pacemakers

Cardiac Rhythm Therapy // Advanced Features // ProMRI. ProMRI. Checklist and Quick Reference Guide

Lead Management for MRI

MRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System

EnTrust D154VRC Single Chamber ICD 35J delivered 8 seconds BOL, 11.8 seconds ERI 10.7 years**** 35cc, 68g Programmable Active Can

SJM MRI ACTIVATOR HANDHELD DEVICE WORKFLOW Model: EX4000. SJM-EDTR Item approved for U.S. use only.

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500)

Cardiac Rhythm Device Management. PBL STOP Your acronym for a standardized follow-up

Non Contrast MRA. Mayil Krishnam. Director, Cardiovascular and Thoracic Imaging University of California, Irvine

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500)

INTERPRETING THE ECG IN PATIENTS WITH PACEMAKERS

Model 5392 EPG Temporary Pacer

Multiple Gated Acquisition (MUGA) Scanning

EHRA Accreditation Exam - Sample MCQs Cardiac Pacing and ICDs

PERIOPERATIVE MANAGEMENT: CARDIAC PACEMAKERS AND DEFIBRILLATORS

Review of Pacemakers and ICD Therapy: Overview and Patient Management

Impaired Regional Myocardial Function Detection Using the Standard Inter-Segmental Integration SINE Wave Curve On Magnetic Resonance Imaging

Is This Thing Working?

SARASOTA MEMORIAL HOSPITAL

12 YEARS PROVEN PERFORMANCE. Sprint Quattro Defibrillation Leads

Cardiac Rhythm Management // Manual // ProMRI. ProMRI. MR conditional device systems

Safety Issue of Static Magnetic Field (1)

Automatic Identification of Implantable Cardioverter-Defibrillator Lead Problems Using Intracardiac Electrograms

MR Advance Techniques. Cardiac Imaging. Class IV

Implantable cardioverter defibrillator, Inappropriate shock, Lead failure

Essentials of Pacemakers and ICD s. Rajesh Banker, MD, MPH

1Pulse sequences for non CE MRA

Cardiac MRI in ACHD What We. ACHD Patients

Assessment of Defibrillation Threshold upon Implantable Cardioverter-Defibrillator implant in Relation to patient s prognosis

Procedure for exceptional magnetic resonance scanning in patients with standard (non-mr-conditional) pacemakers

IMAGEREADY MR CONDITIONAL PACING SYSTEM

It is estimated that after implantation, up to 75% of patients. Original Research

Safety of Pacemakers and Defibrillators in Electromagnetic Navigation Bronchoscopy

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE GUIDANCE EXECUTIVE (GE)

*smith&nephew. MRI Safety Information & Parameters for Smith & Nephew Orthopaedics AG. Hip Implants

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System

SMRT Student Scope Submission

ICD Diagnostics: Making the most of it

UK Biobank. Imaging modality Cardiovascular Magnetic Resonance (CMR) Version th Oct 2015

Safety of Magnetic Resonance Imaging in Patients with Cardiac Devices

Solara CRT-P MRI SureScan W1TR06

Project Title Temporary Pacemaker Training Simulator

Figure 2. Normal ECG tracing. Table 1.

11 YEARS PROVEN PERFORMANCE. Sprint Quattro Defibrillation Leads

New Cardiovascular Devices and Interventions: Non-Contrast MRI for TAVR Abhishek Chaturvedi Assistant Professor. Cardiothoracic Radiology

Cochlear Implants. Medical Procedures. for MED EL CI Systems. AW33290_5.0 (English US)

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE

Everyone Needs a Device Christopher L. Fellows, MD, FACC, FHRS Virginia Mason Medical Center Seattle, Wa.

Practice Questions.

External Distal Radius Fixator. Supplement to the 8 mm rod fixator system

Azure XT DR MRI SureScan W2DR01

Percepta CRT-P MRI SureScan W1TR01

Different indications for pacemaker implantation are the following:

Algovita. MRI Procedure Guidelines. Spinal Cord Stimulation System. 201x

REBEL. Platinum Chromium Coronary Stent System. Patient Information Guide

PACEMAKER INTERPRETATION AND DEVICE MANAGEMENT PART I

Electromagnetic Interference between External Defibrillator and Cardiac Resynchronization Therapy-Pacemaker (CRT-P) Devices

Permanent Pacemaker Implantation Post Cardiac Surgery: A Cautionary Tale

Cochlear Implants. Medical Procedures. for MED EL Implant Systems. AW33290_2.0 (English US)

Flowchart for ICD patients undergoing Surgery or procedures involving diathermy/magnetic fields

Transcription:

Washington University School of Medicine Digital Commons@Becker Open Access Publications 2013 Cardiovascular magnetic resonance with an MR compatible pacemaker Anita R. Bhandiwad Kristopher W. Cummings Michael Crowley Pamela K. Woodard Follow this and additional works at: https://digitalcommons.wustl.edu/open_access_pubs Recommended Citation Bhandiwad, Anita R.; Cummings, Kristopher W.; Crowley, Michael; and Woodard, Pamela K.,,"Cardiovascular magnetic resonance with an MR compatible pacemaker." Journal of Cardiovascular Magnetic Resonance.15,. 18. (2013). https://digitalcommons.wustl.edu/open_access_pubs/1288 This Open Access Publication is brought to you for free and open access by Digital Commons@Becker. It has been accepted for inclusion in Open Access Publications by an authorized administrator of Digital Commons@Becker. For more information, please contact engeszer@wustl.edu.

Bhandiwad et al. Journal of Cardiovascular Magnetic Resonance 2013, 15:18 http://jcmr-online.com/content/15/1/18 CASE REPORT Open Access Cardiovascular magnetic resonance with an MR compatible pacemaker Anita R Bhandiwad 1*, Kristopher W Cummings 2, Michael Crowley 2 and Pamela K Woodard 2 Abstract Magnetic resonance imaging (MRI) within FDA guidelines for the MRI-conditional pacemaker precludes placing the heart at the center of the magnet s bore. This in effect appears to preclude cardiovascular MR. In this manuscript, we describe a protocol for cardiovascular MR of patients with a Revo pacemaker system while operating within FDA guidelines, and the first US case of cardiovascular MR in a patient with a Revo MRI-conditional pacing system despite position constraints. Keywords: MRI-conditional pacemaker, Cardiovascular magnetic resonance, Revo pacer Background Several million people are estimated to currently have cardiac implantable electronic devices (CIEDs), including pacemakers and implanted cardioverter defibrillators (ICD). This number may continue to grow with expanded indications for heart failure and primary prevention. Historically, CIEDs have been considered to be absolute contraindications for magnetic resonance imaging (MRI). However, there is an estimated 50 75% probability that MRI will be indicated for a patient over the device lifetime [1]. There are several concerns regarding the interaction of these devices with the static and pulsed magnetic field. First, the generator or leads may be displaced, although translational forces and torque on the leads have been shown to be small at 1.5 Tesla field strength [2]. Next, the behavior of the device and programming may be altered. For instance, pacemakers may change to asynchronous pacing mode or an ICD may temporarily suspend detection and therapies of ventricular tachyarrhythmias. Pulsed radiofrequency from the MRI may induce voltage pulses that result in oversensing of electrical signals in the magnetic field. Alternatively, pacing inhibition in a pacemakerdependent patient, unintended cardiac stimulation, and possible inappropriate shocks could result [1,3,4]. Finally, radiofrequency-induced heating of myocardial tissue near * Correspondence: abhandiw@dom.wustl.edu 1 Division of Cardiology, Department of Medicine, Washington University School of Medicine, 1020 N. Mason Road, Suite 100, Saint Louis, MO 63141, USA Full list of author information is available at the end of the article the pacemaker lead tip has the potential to cause thermal injury with resultant pacing threshold deterioration or even atrial or ventricular perforation [2]. Therefore, even nonfunctioning leads left without connection to a generator or epicardial leads have been considered a contraindication to MRI. Device programming can mitigate some of these potential risks. However, electrical reset can occur in up to 6% of pacemaker patients undergoing MRI upon exposure to a magnetic field that overrides programming changes [2,5]. Pacemaker inhibition could lead to bradycardia/asystole, or competitive rhythms may occur that can induce fatal tachyarrhythmias [2,4]. Although MR conditional pacemaker, ICD, cardiac resynchronization therapy pacemaker and defibrillator systems are available in Europe and some in Asia, most are investigational in the United States (Biotronik, Berlin, Germany, and St. Jude Medical, St. Paul, Minnesota). Most recently, development and Food and Drug Administration (FDA) approval of the MRI-conditional device, the Medtronic Revo pacing system (Medtronic, Minneapolis, Minnesota), has been a notable advance. Conditions for scanning patients with the Revo system within FDA guidelines include a 6-week delay after pacemaker implantation, 1.5 T static magnetic field strength, maximum specific absorption rate (SAR) of 2 W/kg for each sequence, and maximum slew rate of 200 T/m/s. MR scanning within FDA guidelines for the device precludes placing the heart at the magnet isocenter (center of bore). However, the pacemaker system may pass through 2013 Bhandiwad et al.; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Bhandiwad et al. Journal of Cardiovascular Magnetic Resonance 2013, 15:18 Page 2 of 4 Figure 1 SSFP coronal scout with isocenter below T12. Position confirmed by inferior rib while placing patient in scanner. Note the relatively higher signal at the image isocenter (arrow). isocenter during table positioning. Isocenter must be above the superior surface of the C1 vertebra or below the inferior surface of the vertebral body of T12 [4]. This in effect appears to preclude cardiovascular MR (CMR). In this manuscript, we describe a protocol for CMR of patients with a Revo pacemaker system while operating within FDA guidelines, and the first US case of CMR in a patient with a Revo MRI-conditional pacing system despite position constraints. Figure 3 Late gadolinium enhancement images demonstrating enhancement in the inferior and lateral walls. Findings consistent with infiltrative process and biopsy-confirmed PTLD (solid arrows), and pacemaker lead in right ventricle (dashed arrow). Case presentation A 34-year-old woman had a history of an anterior myocardial infarction following spontaneous left anterior descending coronary artery dissection 11 days postpartum at age 28 and subsequently underwent cardiac Figure 2 Still-frame from cine steady-state free precession image. Localized artifact from sternal wires (dashed arrow) and pacemaker lead in right ventricle (solid arrow). Figure 4 Late gadolinium enhancement image on CMR study 4 months later. Slight improvement in inferior and lateral enhancement (solid arrows).

Bhandiwad et al. Journal of Cardiovascular Magnetic Resonance 2013, 15:18 Page 3 of 4 transplantation. She was found to have chronic inflammation and episodes of acute rejection on endomyocardial biopsies. Echocardiography demonstrated abnormal diastolic function with restrictive filling and course was notable for development of clinical heart failure requiring hospitalization. Biopsies confirmed post-transplant lymphoproliferative disorder (PTLD) consistent with plasmacytoma. CMR demonstrated patchy areas of late gadolinium enhancement (LGE) in the inferior, inferoseptal and lateral walls of the left ventricle consistent with infiltrative process. The patient s coursewas further complicated by development of sinus node dysfunction with sinus pauses of 4.5 seconds. Pacemaker implantation was advised. MRI-compatible dualchamber system was implanted due to the anticipated need for future CMR studies to follow cardiac allograft involvement with chemotherapy [6]. The patient was referred for CMR 6 months after pacer implantation. The scan was performed on 1.5 T whole body scanner (TIM Symphony, Siemens Medical Systems, Malvern, NJ), slew rate 125 T/m/s. A cardiologist, radiologist and MRI physicist were present. Isocenter was placed inferior to T12, determined by the inferior rib (Figure 1). Minor modifications to the flip angle of the cine steadystate free precession (SSFP) sequences were made to maintain SAR < 2 W/kg. The table position was set to FIXED to prevent default movement. Prior to scanning, the device was interrogated: atrial lead impedance 568 ohms, ventricular lead impedance 472 ohms, atrial lead capture threshold 1 V at 0.4 ms, ventricular lead capture threshold 1 V at 0.4 ms, P-wave amplitude sensing 3.4 mv, R-wave amplitude sensing 10.3 mv. The device was switched to SureScan On and ODO mode. Following completion of imaging, device was set to SureScan Off and DDD mode, and interrogation showed no significant change in parameters: atrial lead impedance 544 ohms, ventricular lead impedance 472 ohms, atrial lead capture threshold 1 V at 0.4 ms, ventricular lead capture threshold 1 V at 0.4 ms, P-wave amplitude sensing 3.5 mv, R-wave amplitude sensing 9.9 mv. The patient was monitored throughout the study by telemetry, blood pressure, and voice communication. The patient had no complaints during scanning. A complete CMR study without and with contrast was performed with black blood half-fourier acquisition single-shot turbo spin-echo (HASTE) scout imaging, cine SSFP sequences (TR 3.0 ms, TE 1.3 ms, flip angle < 90 modified to maintain SAR <2 W/Kg) in the 2 and 4- chamber long-axis and short axis cardiac planes, followed by segmented gradient-recalled phase sensitive inversion recovery (PSIR) LGE short and long axis imaging (TR 46 ms, TE 3.4 msec, flip angle 15, IR time 280 msec) performed after intravenous administration of 0.2 mmol/ Kg gadoversetamide (Optimark, Covidien, St. Louis, MO). These images demonstrated patchy LGE of the left ventricular inferior and lateral walls consistent with infiltrative process and known PTLD. Localized artifact from the pacemaker lead in the right ventricle was present without effect on interpretability of images (Figures 2 and 3). Four months later the patient was referred again for CMR to assess response to therapy. A similar protocol as described above was performed. These images demonstrated slight interval decrease in enhancement pattern (Figure 4). Conclusion Quarta et al. described CMR with the MRI-conditional pacing system performed in Europe where positioning restrictions are not required [7]. Following appropriate U.S. imaging protocols for this device, diagnostic quality cardiac images can be obtained despite position of isocenter remote from the heart. Localized artifact from leads does not compromise image interpretability. The MRI-conditional pacemaker system may allow the benefits of MRI to be more accessible to pacemaker patients. Consent Written informed consent was obtained from the patient for publication of this case report and any accompanying images. A copy of the written consent is available for review by the Editor-in-Chief of this journal. Abbreviations (CIEDs): Cardiac implantable electronic devices; (ICD): Implanted cardioverter defibrillators; (MRI): Magnetic resonance imaging; (CMR): Cardiovascular magnetic resonance; (FDA): Food and Drug Administration; (SAR): Specific absorption rate; (PTLD): Post-transplant lymphoproliferative disorder; (LGE): Late gadolinium enhancement; (SSFP): Steady-state free precession; (PSIR): Phase sensitive inversion recovery. Competing interests PKW- Medtronic, consultant. The other authors have no disclosures or conflicts of interest. Authors contributions ARB provided cardiology supervision during scanning, reviewed device interrogations, assisted in image acquisition and interpretation, and drafted the manuscript. KWC assisted with planning scan protocol. MC, a physicist, modified sequences for SAR limitations. PKW planned scan protocol, assisted in image acquisition and interpretation, and helped to draft the manuscript. All authors read and approved the final manuscript. Author details 1 Division of Cardiology, Department of Medicine, Washington University School of Medicine, 1020 N. Mason Road, Suite 100, Saint Louis, MO 63141, USA. 2 Mallinckrodt Institute of Radiology, Washington University School of Medicine, Saint Louis, MO, USA. Received: 31 December 2012 Accepted: 15 January 2013 Published: 15 February 2013 References 1. Kalin R, Stanton MS: Current clinical issues for MRI scanning of pacemaker and defibrillator patients. Pacing Clin Electrophysiol 2005, 28:326 328.

Bhandiwad et al. Journal of Cardiovascular Magnetic Resonance 2013, 15:18 Page 4 of 4 2. Sommer T, Naehle CP, Yang A, et al.: Strategy for Safe Performance of Extrathoracic Magnetic Resonance Imaging at 1.5 Tesla in the Presence of Cardiac Pacemakers in Non Pacemaker-Dependent Patients. Circulation 2006, 114:1285 1292. 3. Reynolds MR, Zimetbaum P: Magnetic resonance imaging and cardiac devices: How safe is safe enough? Ann Intern Med 2011, 155:470 472. 4. Wilkoff BL, Bello D, Taborsky M, et al.: Magnetic resonance imaging in patients with a pacemaker system designed for the magnetic resonance environment. Heart Rhythm 2011, 8:65 73. 5. Nazarian S, Hansford R, Roguin A, et al.: A prospective evaluation of a protocol for magnetic resonance imaging of patients with implanted cardiac devices. Ann Intern Med 2011, 155:415 424. 6. Wang T, Klein JL, Woodard PK, et al.: Plasmacytoma-Like Post-Transplant Lymphoproliferative Disease Occurring in a Cardiac Allograft: A Case Report and Review of Literature. J Clin Oncol 2012, 30 27:e278 e282. 7. Quarta G, Holdright DR, Plant GT, et al.: Cardiovascular magnetic resonance in cardiac sarcoidosis with MR conditional pacemaker in situ. J Cardiovasc Magn Reson 2011, 13:26. doi:10.1186/1532-429x-15-18 Cite this article as: Bhandiwad et al.: Cardiovascular magnetic resonance with an MR compatible pacemaker. Journal of Cardiovascular Magnetic Resonance 2013 15:18. Submit your next manuscript to BioMed Central and take full advantage of: Convenient online submission Thorough peer review No space constraints or color figure charges Immediate publication on acceptance Inclusion in PubMed, CAS, Scopus and Google Scholar Research which is freely available for redistribution Submit your manuscript at www.biomedcentral.com/submit